HomeMy WebLinkAboutA-001-GENERAL NOTES, SYMBOLS, AND STANDARD MOUNTING HEIGHTSWATER CLOSET
SIDE WALL
WATER CLOSET
BACK WALL
ACCESSIBLE FIXTURES INDICATED WITH
HATCH ON FLOOR PLAN
WHEELCHAIR ACCESSIBLE
TOILET COMPARTMENT
AMBULATORY ACCESSIBLE
TOILET COMPARTMENT
70"56" MIN. @ WALL-HUNG TOILET
59" MIN. @ FLOOR-MOUNTED TOILET
18" MIN.1 1/2" MIN.7" - 9"9"6"
60" MIN.9"6"
24"60" MIN.TOILET PARTITION
WHERE OCCURS
TOILET PAPER
MOUNTING AREA
URINAL SCREEN
WHERE OCCURS
TOE CLEARANCE
SPACE
TOE CLEARANCE
SPACE
ACCESSIBLE SINK
BOWL -6 1/2" DEEP
MIN. ACCESSIBLE
KNEE CLEARANCE
WATER CLOSET
SIDE WALL
WATER CLOSET
BACK WALL
URINAL LAVATORY OR VANITY SINK ELECTRIC WATER
COOLER
TRANSFER ADA
SHOWER36" MAX.27" MIN. CLEARHAND HELD
ADJUSTABLE SHOWER
HEAD (ADA)
CONTROL AREA
FOLD DOWN
SHOWER
SEAT
1 1/2" DIAMETER GRAB
BAR, 1 1/2" MIN. GAP
FROM WALL (TYPICAL)
40"40"12"
18" GRAB BAR*
42" GRAB BAR*
36" GRAB BAR*
* 1 1/2" MIN. CLEAR REQUIRED
AROUND ALL GRAB BARS34"12" MIN.24" MIN.15" STD.17" H.C.17"24" STD.17" MAX. H.C.34" MAX.27"9"8"
11"
15" MIN.
ACCESSIBLE FIXTURES INDICATED WITH
HATCH ON FLOOR PLAN
ACCESSIBLE FIXTURES INDICATED WITH
HATCH ON FLOOR PLAN 18"18"18"40"48".38" MAX.33" - 36"MAX.1'-0"9"6"
TOE CLEARANCE
SPACE 9"6"
TOE CLEARANCE
SPACE
60" MIN.
37" MAX.
35" MIN.
40"
12"40"34"15" STD.17" H.C.70"18" MIN.1 1/2" MIN.7" - 9"
TOILET PARTITION
WHERE OCCURS
TOILET PAPER
MOUNTING AREA
18" GRAB BAR*
42" GRAB BAR*
36" GRAB BAR*
* 1 1/2" MIN. CLEAR REQUIRED
AROUND ALL GRAB BARS
EQ EQ
ACCESSIBLE FIXTURES INDICATED WITH
HATCH ON FLOOR PLAN
ENLARGED DRAWING REFERENCE
ELEVATION DATUM
REFERENCE
NORTH ARROW
DRAWING NUMBER
SHEET NUMBER
BUILDING SECTION CUT REFERENCE
W10 101A101
1
1
Room Name
101
-
KEY NOTE (SHAPE VARIES)
ALIGN DESIGNATED
SURFACES
REVISION REFERENCE
WINDOW NUMBER
DOOR / DOOR NUMBER
ROOM NAME AND NUMBER
NEW
A
DRAWING NUMBER
SHEET NUMBER
WALL SECTION CUT REFERENCE
DRAWING NUMBER
SHEET NUMBER
ELEVATION REFERENCE
EXISTING
ROOF SLOPE -ARROW
POINTS TOWARD DRAIN
1/4" / FOOT
1
PARTITION TYPE SYMBOL*
M8A.D.2.A
S2A.P
*REFER TO INTERIOR PARTITION LEGEND
COLUMN GRIDS
INDICATES NORTH DIRECTION
1
A101
1
A101
1
A101
CT-1
ACCESSIBLE PLUMBING
FIXTURES INDICATED WITH
HATCH ON FLOOR PLANS
EARTH
NOTE: PATTERNS SHOWN REPRESENT CUT MATERIALS IN
PLAN OR SECTION, UNLESS NOTED OTHERWISE ABOVE.
GRANULAR FILL
CAST-IN-PLACE CONCRETE
PRECAST CONCRETE, CAST
STONE
CONCRETE MASONRY UNIT
BRICK MASONRY
STONE: LIMESTONE, GRANITE,
MARBLE OR AS NOTED
METAL: TYPE AS NOTED
METAL: ROLLED SHAPES
WOOD FRAMING / BLOCKING:
CONTINOUS
WOOD SHIM
FINISHED WOOD
SHOWN CUT AND ELEVATION
PLYWOOD
EIFS
SPRAYED FIREPROOFING
SHOWN ON ROLLED SHAPE
BATT INSULATION: THERMAL
OR ACOUSTICAL, UNO
RIGID INSULATION: THERMAL,
ACOUSTICAL, OR SAFING
SHEATHING: GYPSUM, OR AS
NOTED
GYPSUM BOARD
TILE: CERAMIC, QUARRY, UNO
RESINOUS FLOORING:
TERRAZO, TROWEL-ON, UNO
ACOUSTICAL CEILING TILE
GRATING
SHOWN IN PLAN
INSULATED GLASS:
(SMALL SCALE)
GRATING
MEMBRANE: WATERPROOF,
ROOF, DAMPPROOFING
AIR BARRIER SYSTEM
INSULATED GLASS:
(DETAIL)
TERRA COTTA, STRUCTURAL
CLAY TILE
CARPET, CARPET TILE (DETAIL)
SAND, GROUT
AS NOTED
GLASS FIBER REINFORCED
CONCRETE SIDING OR TRIM
ENGINEERED WOOD: GLUE
LAMINATED
PLASTER ON METAL LATH
WOOD FLOOR, WOOD
SHINGLES, OR SIDING
ANGLE
MISCELLANEOUS
CENTER LINE
NUMBER#
TOILET TISSUE/
SEAT COVER
DISPENSERCOORDINATE WITH B.O. MIRRORTOP OF CONTROLCL OF SLOTSANITARY NAPKIN/
TAMPON VENDOR
PAPER TOWEL
DISPENSER/
WASTE
RECEPTACLE CL OF HOOKCL OF BARTOP OF UNITTOP OF SHELFTOP OF COUNTER SURFACETOP OF UNITSOAP DISPENSERGRAB BAR JANITOR'S
CLOSET SELF
COAT HOOK/
DOOR BUMPERBOTTOM EDGE OF REFLECTIVE SURFACEMIRRORRECESSED
PAPER TOWEL
DISPENSER CL OF UNITCLOTHE
S HOOK
CHANGING
STATIONTOP OF CHANGING SURFACETOP OF HOOKFOLDING
UTILITY SHELFTOP OF SHELF WHEN IN USE34"34"34"34"70"@ COUNTER & LAVS40"48"33 1/2"MAX42"ITEM:MOUNTING HEIGHT:DIMENSION FROM FINISH FLOOR TO:TOILET TISSUE/
SANITARY NAPKIN
DISPOSAL/ SEAT
COVER
DISPENSER 48" ADA60" TYP.42"MAX. 48"MAX. 48"PAPER TOWEL
DISPENSERTOP OF HANDLE24"15" MIN.25"15" MIN.TOILET PAPER
DISPENSER
TOILET PAPER
HOLDER BOTTOM OF UNITBOTTOM OF UNITMAX. 48"30"SANITARY
NAPKIN
DISPOSALTOP OF UNITWARM-AIR
HAND DRYERCL OF PUSH BUTTONOR PER MANUFACTURER'S RECOMMENDATION40"MAX. 40"WARM AIR
HAND DRYER
A. THESE GENERAL NOTES APPLY TO ARCHITECTURAL
DRAWINGS.
B. WORK SHOWN ON THE DRAWINGS SHALL BE BASE BID
UNLESS SPECIFICALLY NOTED TO BE BY ALTERNATE BID.
C. FIELD VERIFY EXISTING FINISH FLOOR ELEVATIONS PRIOR TO
STARTING CONSTRUCTION. MATCH NEW FLOOR ELEVATIONS
WITH EXISTING UNLESS NOTED OTHERWISE.
D. DIMENSIONS TO EXISTING CONSTRUCTION ARE TO FINISH
SURFACE. DIMENSIONS TO NEW CONSTRUCTION ARE TO
STRUCTURAL CENTERLINE, FACE OF CONCRETE, FACE OF
MASONRY CONSTRUCTION, OR TO FACE OF EXTERIOR OF
INTERIOR PARTITION TYPE UNLESS NOTED OTHERWISE.
FIELD VERIFY ALL CONDITIONS AND DIMENSIONS PRIOR TO
STARTING WORK AND NOTIFY ARCHITECT IMMEDIATELY IF
DISCREPANCIES ARE FOUND BETWEEN CONTRACT
DOCUMENTS AND ACTUAL FIELD CONDITIONS.
E. DO NOT SCALE DRAWINGS. REFER DIMENSION QUESTIONS
TO ARCHITECT FOR INTERPRETATION.
F. DOOR AND FRAME NUMBERS CORRESPOND TO RESPECTIVE
ROOM NUMBERS. IN ROOMS WITH MULTIPLE OPENINGS, A
SUFFIX HAS BEEN ADDED TO DOOR NUMBERS, I.E., A101-B.
G. LOCATE INSIDE FACE OF DOOR FRAME JAMBS 6 INCHES
FROM FINISH FACE OF ADJACENT WALLS UNLESS NOTED
OTHERWISE.
H. COORDINATE EQUIPMENT WORK WITH MANUFACTURERS AND
SUPPLIERS TO INSURE PROPER ROUGH-IN CLEARANCES FOR
INSTALLATION, USE AND MAINTENANCE.
I. PROTECT EXISTING SURFACES TO REMAIN THAT ARE NOT
INCLUDED IN SCOPE OF WORK BUT THAT ARE WITHIN AREAS
OF CONSTRUCTION ACTIVITY.
J. PATCH, REPAIR AND RESTORE EXISTING FINISHES AND
SURFACES TO AS NEW CONDITION AS REQUIRED TO MATCH
SURROUNDING MATERIALS OR TO PROVIDE APPROPRIATE
SUBSTRATE PRIOR TO INSTALLING NEW FINISHES. AREAS
NOTED TO BE PATCHED OR REPAIRED ON THE DRAWINGS
ARE GIVEN FOR REFERENCE AND SHALL NOT BE
INTERPRETED TO LIMIT THE SCOPE OF WORK.
K. VERTICAL COURSING FOR NEW MASONRY WALL
CONSTRUCTION SHALL EQUAL EIGHT INCHES (8") FOR ONE
CONCRETE MASONRY UNIT PLUS ONE MORTAR JOINT AND
THREE BRICK COURSES PLUS THREE MORTAR JOINTS,
UNLESS NOTED OTHERWISE.
L. TOOTH NEW MASONRY INTO EVERY OTHER COURSE OF
EXISTING MASONRY UNLESS OTHERWISE INDICATED.
PROVIDE HORIZONTAL ANCHORS BETWEEN NEW AND
EXISTING MASONRY AT CONDITIONS THAT PROHIBIT
TOOTHED-TYPE CONSTRUCTION. HORIZONTAL JOINTS OF
NEW MASONRY SHALL MATCH EXISTING UNLESS OTHERWISE
INDICATED. NEW MASONRY BOND SHALL MATCH EXISTING
UNLESS OTHERWISE INDICATED.
M. PROVIDE CONTROL JOINTS (C.J.) IN MASONRY
CONSTRUCTION AS INDICATED. WHERE NOT SHOWN,
PROVIDE MAXIMUM SPACING BETWEEN VERTICAL JOINTS OF
30'-0”AND MAXIMUM DISTANCE BETWEEN OUTSIDE CORNERS
AND JOINTS OF 8'-0”. PROVIDE JOINTS BETWEEN INTERIOR
LOAD BEARING AND NON-LOAD BEARING PARTITIONS, AT ALL
ABRUPT CHANGES IN WALL HEIGHT, AT CHANGES IN
PARTITION THICKNESS AND AT PILASTER LOCATIONS. VERIFY
FINAL CONTROL JOINT LOCATIONS WITH ARCHITECT PRIOR
TO STARTING WORK.
N. PROVIDE CONTROL JOINTS (C.J.) IN GYPSUM BOARD WALL
CONSTRUCTION AS INDICATED. VERIFY FINAL CONTROL JOINT
LOCATIONS WHETHER OR NOT INDICATED ON THE DRAWINGS
WITH ARCHITECT PRIOR TO STARTING WORK. PROVIDE
MAXIMUM SPACING BETWEEN JOINTS AS FOLLOWS:
a. CEILINGS: INSTALL CONTROL JOINTS IN CEILINGS PER
ASTM C840 IN ALL CEILINGS WITH AREA EXCEEDING 250
S.F., SPACED 50'-0" O.C. MAXIMUM. CONTROL JOINTS
ALSO TO BE INSTALLED WHERE FRAMING OR FURRING
CHANGES DIRECTION. REFER TO REFLECTED CEILING
PLANS FOR DESIRED LOCATIONS.
b. WALLS: INSTALL CONTROL JOINTS IN INTERIOR
PARTITIONS AND FURRING PER ASTM C840 IN AREAS
EXCEEDING 30'-0", SPACED 30'-0" O.C. MAXIMUM. REFER
TO INTERIOR ELEVATIONS FOR DESIRED LOCATIONS.
O. WOOD OR METAL STUD SPACING SHALL BE 16”ON CENTER
MAXIMUM UNLESS OTHERWISE REQUIRED BY DELEGATED
DESIGN OR NOTED OTHERWISE.
P. VERIFY MOUNTING HEIGHTS OF ACCESSORIES, EQUIPMENT,
DOOR HARDWARE, CASEWORK, ETC., AND PROVIDE SOLID
BLOCKING BEHIND ITEMS REQUIRING ANCHORAGE. PROVIDE
FIRE TREATED WOOD BLOCKING OR METAL STRAPS
BETWEEN FRAMING MEMBERS AS REQUIRED TO SUPPORT
WEIGHT AND USE OF ITEMS TO BE SUPPORTED. WHERE
MOUNTING HEIGHTS ARE NOT INDICATED, MOUNT ITEMS IN
ACCORDANCE WITH RECOGNIZED INDUSTRY STANDARDS,
COORDINATE LOCATIONS WITH MANUFACTURER OR
SUPPLIER AND REFER MOUNTING HEIGHT QUESTIONS TO
ARCHITECT FOR INTERPRETATION.
Q. PROVIDE SEALANT AT PERIMETERS OF METAL FRAMES AT
OPENINGS AND AT JOINTS BETWEEN DISSIMILAR MATERIALS
SUCH AS GYPSUM BOARD AND MASONRY, MASONRY AND
CONCRETE, CASEWORK AND WALLS, ETC. UNLESS
OTHERWISE INDICATED.
R. STAIRWELLS, ELEVATOR HOISTWAYS, ELEVATOR CONTROL
ROOM, AND SHAFT WALLS SHALL BE TWO-HOUR FIRE-RATED
CONSTRUCTION UNLESS OTHERWISE INDICATED.
S. REPAIR AND PATCH SPRAYED FIRE-RESISTIVE AND FIRESTOP
MATERIALS WHERE DAMAGED DUE TO INSTALLATION OF NEW
MATERIALS TO RESTORE SPECIFIED FIRE RATING.
T. THESE NOTES ARE APPLICABLE TO THIS BID PACKAGE ONLY
AND MAY NOT BE APPLICABLE TO FUTURE BID PACKAGES.
SOME WORK WHICH WAS INCLUDED IN PREVIOUS BID
PACKAGES OR WILL BE INCLUDED IN FUTURE BID PACKAGES
IS SHOWN ON THESE CONSTRUCTION DOCUMENTS FOR
REFERENCE PURPOSES ONLY AND IS IDENTIFIED AS SUCH.
U. DO NOT BEGIN WORK THAT MAY REQUIRE COORDINATION,
SUCH AS CEILING INSTALLATION, PRIOR TO FINAL SUBMITTAL
TO ARCHITECT OF COORDINATION DRAWINGS FOR MEP
ITEMS BOTH ABOVE CEIING AND IN CEILING, NOR PRIOR TO
RESOLUTION AND APPROVAL OF COORDINATION ISSUES.
V. REFER TO LIFE SAFETY PLAN DRAWINGS AND CODE
SUMMARY FOR FIRE-RATED FLOOR, WALL, CEILING AND ROOF
LOCATIONS. INSTALL FIRESTOPPING AT PENETRATIONS IN
RATED CONSTRUCTION AND AT TOPS OF RATED WALLS.
W. REFER TO STRUCTURAL DRAWINGS FOR FOOTING AND
FOUNDATION DRAINS, UNDERSLAB DRAINAGE AND BACKFILL
REQUIREMENTS.
X. REFER TO LANDSCAPE AND CIVIL DRAWINGS FOR SITE
ELEMENTS AND IMPROVEMENTS ADJACENT TO BUILDING
EXTERIOR.
Y. REFER TO CIVIL DRAWINGS FOR FINISH FLOOR ELEVATIONS.
100'-0”= 862.39'
Z. REFER TO A-002 FOR PARTITION CONSTRUCTION TYPE.
SHEET TITLE
SHEET NUMBER
Kite Realty Group
30 S. Meridian Street, #1100
Indianapolis, Indiana 46204
Owner
Republic Airways Holdings
RATIO
101 South Pennsylvania Street
Indianapolis, Indiana 46204
317-633-4040
Architect
McComas/O'donnell & Naccarato
Structural Engineer
Mechanical / Plumbing Design/Builder
Civil Engineer
8909 Purdue Road, Suite 300
Indianapolis, Indiana 46268
1717 E. 116th Street, Suite 200
Carmel, Indiana 46032
317-580-0402
DEEM LLC
6831 E 32nd Street
Indianapolis, Indiana 46226
Kimley Horn
250 East 96th Street, Suite 580
Indianapolis, Indiana 46240
PROJECT NO.
SHEET ISSUE
NOT FOR CONSTRUCTION
SEAL | DATE
COPYRIGHT NOTICE: THIS ARCHITECTURAL
AND ENGINEERING DRAWING IS GIVEN IN
CONFIDENCE AND SHALL BE USED ONLY
PURSUANT TO THE AGREEMENT WITH RATIO.
NO OTHER USE, DISSEMINATION OR
DUPLICATION MAY BE MADE WITHOUT PRIOR
WRITTEN CONSENT OF RATIO. ALL COMMON
LAW RIGHTS OF COPYRIGHT AND OTHERWISE
ARE HEREBY SPECIFICALLY RESERVED.
Electrical Design/Builder
Barth Electric Co., Inc.
1934 N. Illinois Street
Indianapolis, Indiana 46202
10/29/2021 4:10:17 PMA-001
GENERAL NOTES,
SYMBOLS, AND
STANDARD
MOUNTING HEIGHTS
21040.000
Republic Airways
Hotel
12197 N Meridian St.
Carmel, IN 46032
STANDARD-PLUMBING FIXTURE REQUIREMENTS
ARCHITECTURAL SYMBOLS LEGEND
ARCHITECTURAL MATERIAL LEGEND
T
T. THICKNESS
T.B. TACK BOARD
TBD TO BE DETERMINED
T.C. TOP OF CURB
T.D. TOP OF DECK
TECH. TECHNICAL
TEL. TELEPHONE
TEMP. TEMPORARY
T&G TONGUE AND GROOVE
T.M. TOP OF MASONRY
TMPRD. TEMPERED
T/O TOP OF
T.P. TOP OF PAVEMENT
T.S. TOP OF STEEL
T.W. TOP OF WALL
TYP. TYPICAL
U
U.N.O. UNLESS NOTED OTHERWISE
UTIL. UTILITY
U.V. UNIT VENTILATOR
V
VCT VINYL COMPOSITION TILE
VERT. VERTICAL
VEST. VESTIBULE
VIF VERIFY IN FIELD
W
W WIDE/WIDTH
W/ WITH
W.C. WATER CLOSET
WD WOOD
W.H. WATER HEATER
W/O WITHOUT
WT. WEIGHT
W.W.F. WELDED WIRE FABRIC
M
MAX. MAXIMUM
MB MARKER BOARD
M.C. MECHANICAL CONTRACTOR
M.D.F. MEDIUM DENSITY FIBERBOARD
MECH. MECHANICAL
M.E.P. MECH./ELECT./PLUMBING
MFR. MANUFACTURER(ING)
M.H. MANHOLE
MIN. MINIMUM
MISC. MISCELLANEOUS
M.O. MASONRY OPENING
MTL. METAL
N
N.A.F. NO APPLIED FINNISH
N.I.C. NOT IN CONTRACT
NO. NUMBER
N.T.S. NOT TO SCALE
O
O.A. OVER ALL
O.C. ON CENTER
O.D. OUTSIDE DIAMETER
O.F.C.I. OWNER FURNISHED-CONTRACTOR
INSTALLED
O.F.O.I. OWNER FURNISHED-OWNER
INSTALLED
O.H. OPPOSITE HAND
OPG. OPENING
OPP. OPPOSITE
P
P.L. PROPERTY LINE
P. LAM PLASTIC LAMINATE
PLAS. PLASTER
PR. PAIR
PREFAB. PREFABRICATED
PT. BD. PARTICLE BOARD
PTD. PAINTED
PWD. PLYWOOD
Q
Q.T. QUARRY TILE
R
R RADIUS
R.C.P. REFLECTED CEILING PLAN
R.D. ROOF DRAIN
REF. REFERENCE
REFL. REFLECTED
REINF. REINFORCED
RESIL. RESILIENT
R.H. RIGHT HAND
RM ROOM
R.O. ROUGH OPENING
S
SCHED. SCHEDULE
S.D. SOAP DISPENSER
SECT. SECTION
S.F. SQUARE FEET
SHT. SHEET
SIM. SIMILAR
SPEC. SPECIFICATION
SQ. SQUARE
S.S. STAINLESS STEEL
STD. STANDARD
STL. STEEL
STOR. STORAGE
STRUCT. STRUCTURAL
SUSP. SUSPEND(ED)
SYM. SYMMETRICAL
F
F-R FIRE RESISTIVE
FAB. FABRICATE/FABRICATOR
F.C.U. FAN COIL UNIT
F.D. FLOOR DRAIN
F.E. FIRE EXTINGUISHER
F.E.C. FIRE EXTINGUISHER CABINET
F.F.E. FINISH FLOOR ELEVATION
F.F.&E. FURNISHINGS, FIXTURES AND
EQUIPMENT
F.H.C. FIRE HOSE CABINET
FIN. FINISH(ED)
FLR. FLOOR
FLUOR. FLUORESCENT
F/O FACE OF
F.O. FINISH OPENING
F.O.B. FACE OF BLOCK
F.O.BR. FACE OF BRICK
F.O.C. FACE OF CONCRETE
F.O.F. FACE OF FINISH
F.O.G. FACE OF GYPSUM BD.
F.O.S. FACE OF STUD
FPRF. FIREPROOF
FT. FOOT/FEET
F.V. FIELD VERIFY
G
GA. GAUGE
G.C. GENERAL CONTRACTOR
GEN. GENERAL
GL. GLASS
G.W.B./
GWB
GYPSUM WALL BOARD
H
H. HEIGHT
HB HOSE BIBB
HDWR. HARDWARE
H.M. HOLLOW METAL
HORIZ. HORIZONTAL
HT. HEIGHT
HVAC. HEATING, VENTILATION & A.C.
H.W. HOT WATER
I
I.D. INSIDE DIAMETER
INCAN. INCANDESCENT
INFO. INFORMATION
INSUL. INSULATION
INT. INTERIOR
J
JAN. JANITOR
J.C. JANITOR CLOSET
JST. BRG. JOIST BEARING
JT. JOINT
L
L LENGTH
LAV. LAVATORY
LB. POUND
L.H. LEFT HAND
L.L.H. LONG LEG HORIZONTAL
L.L.O. LONG LEG OUT
L.L.V. LONG LEG VERTICAL
A
A/C AIR CONDITIONING
ACOUS. ACOUSTICAL
A.C.T. ACOUSTICAL CEILING TILE
ACP ACOUSTICAL CEILING PANEL
ADA AMERICANS W/DISABILITIES ACT
ADAAG AMERICANS W/DISABILITIES
ACCESSIBILITY GUIDELINES
ADJ. ADJUSTABLE
A/E ARCHITECT/ENGINEER
A.F.F. ABOVE FINISHED FLOOR
ALT. ALTERNATE
ALUM. ALUMINUM
A.P. ACCESS PANEL
ARCH. ARCHITECT/ARCHITECTURAL
A.V. AUDIO/VISUAL
B
BD. BOARD
BITUM. BITUMINOUS
BLDG. BUILDING
B/O BOTTOM OF
B.O.W. BOTTOM OF WALL
BSMT. BASEMENT
C
CAB. CABINET
C.F.C.I. CONTRACTOR
FURNISHED-CONTRACTOR INSTALLED
C.G. CORNER GUARD
C.I.P. CAST-IN-PLACE
C.J. CONTROL JOINT
CL CENTERLINE
CLG. CEILING
CLR CLEAR(ANCE)
C.M. CONSTRUCTION MANAGER
CMP COMPOSITE METAL PANEL
C.M.U. CONCRETE MASONRY UNIT
COL. COLUMN
CONC. CONCRETE
CONST. CONSTRUCTION
CONT. CONTINUOUS
CONTR. CONTRACTOR
COOR. COORDINATE
CPT. CARPET
C.T. CERAMIC TILE
C.W. COLD WATER
D
D.E.F.S. DIRECT APPLIED EXTERIOR FINISH
SYSTEM
DEPT. DEPARTMENT
DET. DETAIL
D.F. DRINKING FOUNTAIN
DIA. DIAMETER
DIM. DIMENSION
DISP. DISPENSER
D.M.B. DRY MARKER BOARD
DN DOWN
DS DOWNSPOUT
DWG. DRAWING
E
EA. EACH
E.C. ELECTRICAL CONTRACTOR
E.I.F.S. EXTERIOR INSULATION FINISH SYSTEM
E.J. EXPANSION JOINT
EL ELEVATION
ELEC. ELECTRIC/ELECTRICAL
ELEV. ELEVATOR/ELEVATION
ENGR. ENGINEER
E.P. ELECTRICAL PANEL
EQ. EQUAL
EQUIP. EQUIPMENT
E.W.C. ELECTRIC WATER COOLER
EXIST. EXISTING
EXP. EXPOSED
EXT. EXTERIOR
ABBREVIATIONS
STANDARD TOILET ROOM ACCESSORY MOUNTING HEIGHTS
GENERAL ARCHITECTURAL NOTES
1 BID PACKAGE #1 08/30/21
2 DESIGN DEVELOPMENT 10/01/21
3 SHELL AND CORE PERMIT SET 10/15/21
10/15/21