HomeMy WebLinkAboutA-002-INTERIOR PARTITION TYPES AND STANDARD PARTITION DETAILSPARTITION TYPE SYMBOL
PARTITION TYPE
FIRE RATING (I.E. 1= 1 HOUR)
PARTITION HEIGHT CODE
NEW PARTITIONS
EXISTING PARTITIONS TO REMAIN
PARTITIONS TO BE DEMOLISHED
M8A.D.2.A
S2A.P
ADDITIONAL PARTITION
DESIGNATION, WHERE
OCCURS
PARTITION DESIGNATION
ACOUSTICAL ATTENUATION
REQ'D
HEIGHT AS
INDICATED IN
INCHES OR (V)
INDICATES
HEIGHT THAT
VARIES
(C) TERMINATE AT CEILING
(P) TERMINATE 6" ABOVE CEILING
(D) TERMINATE AT FLOOR / ROOF DECK
6"REFER TO WALL SECTION FOR CONSTRUCTIONWS
* FIRE RATING AND ACOUSTICAL ATTENUATION
WHEN REQUIRED BY PARTITION SYMBOL 4 7/8"S3A 3 5/8" METAL STUDS WITH (1) LAYER 5/8"
GYPSUM WALL BOARD EACH SIDE
* 1 HR RATED UL419
* ACOUSTIC ATTEN. COMPONENTS
STC-44
5 1/4"S4Y 4" METAL SHAFT WALL STUDS WITH (2)
LAYERS 5/8" GYPSUM WALL BOARD ONE
SIDE AND 1" GYPSUM SHAFT LINER
* 2 HR RATED U417
* ACOUSTIC ATTEN. COMPONENTS
STC-39
M6A 5 5/8" CONCRETE MASONRY UNIT,
RUNNING BOND
* 2 HR RATED UL906
* ACOUSTIC ATTEN. COMPONENTS
STC-46 5 5/8"M8A 7 5/8" CONCRETE MASONRY UNIT,
RUNNING BOND
7 5/8"6 1/8"S3B 3 5/8" METAL STUDS WITH (2) LAYERS 5/8"
TYPE X GYPSUM WALL BOARD EACH SIDE
* 2 HR RATED U419
* ACOUSTIC ATTEN. COMPONENTS
STC-50
7 1/4"S6A 6" METAL STUDS WITH (1) LAYER 5/8"
GYPSUM WALL BOARD EACH SIDE
* ACOUSTIC ATTEN. COMPONENTS
STC-44 2 1/8"S1FA 1 1/2" METAL 'Z' FURRING WITH (1) LAYER
5/8" GYPSUM WALL BOARD ONE SIDE
M8E 7 5/8" CONCRETE MASONRY UNIT WITH
(1) LAYER 5/8" GYPSUM WALL BOARD
OVER 1 1/2" METAL FURRING ONE SIDE
9 3/4"1'-0"S33A DOUBLE 3 5/8" METAL STUDS WITH (1)
LAYER 5/8" GYPSUM WALL BOARD EACH
SIDE
3 1/2" SPACE BETWEEN STUDS
C8A 8" CAST IN PLACE CONCRETE
* 2 HR RATED (refer to 'equivalent
thickiness' tables in IBC-721.2.1.1)
* ACOUSTIC ATTEN. COMPONENTS STC
>54 (rating based on concrete density-verify
concrete density)8"7 1/4"F6A 6" METAL STUDS WITH (1) LAYER 5/8"
GYPSUM WALL BOARD EACH SIDE 4 1/4"S3C 3 5/8" METAL STUDS WITH (1) LAYER 5/8"
GYPSUM WALL BOARD ONE SIDE
4 1/4"8 1/2"S6B 6" METAL STUDS WITH (1) LAYER 5/8"
GYPSUM WALL BOARD EACH SIDE
* 1 HR RATED U411
* ACOUSTIC ATTEN. COMPONENTS
STC-51
4'-0"FIRE EXTINGUISHERFIRE EXTINGUISHER CABINET, FIREHOSE CABINET, HOSE VALVE CABINET, OR ANY COMBINATION OF THE ABOVE6"ELECTRICAL, SWITCHES OR RECEPTACLES OVER COUNTERS OR SIMILAR WORK SURFACES2"2"
2"2"1'-3"ELECTRICAL OR RECEPTACLE TRIM PLATESDOOR FRAME OR
WINDOW FRAME
4'-0"6"6'-8"WALL END OR EDGE
(WHERE OCCURS)
FIRE ALARM NOTE:
ENTIRE LENS TO BE NOT LESS THAN 80" AND
NOT GREATER THAN 96" AFF
THERMOSTAT OR
TEMPERATURE CONTROL
TELEPHONES, DOOR SWITCHES,
DOOR CONTROLLERS, FIRE ALARM
PULL SWITCHES AND SIMILAR ITEMS
(THE INTENT IS TO ALIGN TOPS OF
ALL OPERABLE ITEMS WHILE
ALLOWING THE OPERABLE PARTS
TO BE LESS THAN 4'-0" AFF)
ELECTRICAL RECEPTACLES -SINGLE,
GANGED, OR SEPARATED BY 2"
WINDOW, DOOR OR
"FEATURE" THAT
SEPARATES WALL
INTO SEGMENTS
EQEQ
WALL END OR EDGE
(WHERE OCCURS)
WALL SEGMENT 24" WIDE OR LESS
2"2"
NOTES:
1. USE THIS DETAIL TO LOCATE
DEVICES THAT ARE INDICATED ON
THE DRAWINGS BUT NOT
LOCATED BY DIMENSION, OR TO
LOCATE REQUIRED DEVICES THAT
ARE NOT INDICATED ON THE
DRAWINGS.
2. ALIGN MULTIPLE DEVICES
HORIZONTALLY AND/OR
VERTICALLY AS DETAILED.
3. ITEMS OTHER THAN ELECTRICAL
RECEPTACLES SHALL BE
MOUNTED NEAR DOORWAYS OR
INTERSECTING WALLS AS
DETAILED SO AS NOT TO
INTERFERE WITH THE PLACEMENT
OF ART OR FUNITURE -EXCEPT
THAT WHERE THE WALL SEGMENT
IS LESS THAN 24" WIDE, CENTER
THE DEVICES AS DETAILED.
ELECTRICAL RECEPTACLES -
SINGLE, GANGED, OR
SEPARATED BY 2"
COLUMN
OR
PILASTER FIRE ALARM NOTE:
ENTIRE LENS TO BE NOT
LESS THAN 80" AND NOT
GREATER THAN 96" AFF
EQEQ.
TELEPHONES, DOOR
SWITCHES, DOOR
CONTROLLERS, FIRE
ALARM PULL
SWITCHES AND
SIMILAR ITEMS
2"2"
WHEELCHAIR
ACCESSIBLE
TOILET COMPARTMENT
* 04A AT WOMEN'S
RESTROOMS
**
AMBULATORY
ACCESSIBLE
TOILET COMPARTMENT
* 04A AT WOMEN'S
RESTROOMS
TOILET COMPARTMENT
* 04A AT WOMEN'S
RESTROOMS
*
STANDARD TOILET COMPARTMENT TYPES -
TYPICAL ACCESSORIES
A B C
03C
05B
04A
03A
05D
05F
03C
03A
04A 04A
03A
03C
05D
05F
05D
05F
REFERENCE STANDARD PLUMBING FIXTURE REQUIREMENTS AND STANDARD TOILET TOOM ACCESSORY
MOUNTING HEIGHTS ON A-001 FOR ADDITIONAL INFORMATION UNLESS OTHERWISE NOTED.
EQ EQ1'-5"EQ EQ
TYPICAL DIMENSIONS UNLESS OTHERWISE NOTED
3'-0"
A. ALL WALLS ARE TYPE S6B.D UNLESS NOTED OTHERWISE.
B. PARTITION SYMBOLS APPEAR ON 1/8" =1'-0" FLOOR PLANS
AND 1/4"=1'-0" UNIT PLANS FOR WALLS THAT ARE WITHIN
INDIVIDUAL UNITS.
C. REFER TO FINISH AND CEILING PLANS FOR WALL FINISH,
WALL BASE, AND CEILING INFORMATION.
D. REFER TO WALL SECTIONS FOR EXTERIOR WALL
CONSTRUCTION.
E. PROVIDE MOLD AND MOISTURE RESISTANT GYPSUM
BOARD IN ALL ROOMS CONTAINING OPERABLE PLUMBING
FIXTURES AND WITHIN 4'-0" OF DRINKING FOUNTAINS /
WATER COOLERS, UNLESS NOTED OTHERWISE.
F. PROVIDE LATERAL BRACING AT 48" ON CENTER FOR NON-
STRUCTURAL METAL FRAMED PARTITIONS WHICH EXTEND
ABOVE THE CEILING UNLESS NOTED OTHERWISE. LATERAL
BRACING NOT REQUIRED FOR PARTITIONS THAT EXTEND
TO THE DECK ABOVE UNLESS NOTED OTHERWISE.
G. PROVIDE FIRE RESISTIVE RATED GYPSUM BOARD AT ALL
RATED ASSEMBLIES TO MEET ASSEMBLY REQUIREMENTS.
H. PROVIDE FIRE RESISTIVE JOINT SYSTEMS EQUAL TO WALL
RATING AT ALL PENETRATIONS AND AT HEAD / FLOOR
INTERSECTIONS WITH RATED ASSEMBLIES.
I. PROVIDE ACOUSTICAL SEALANT AT WALL SILL, HEAD,
PENETRATIONS AND ADDITIONAL SPECIFIED SOUND
ATTENUATION COMPONENTS AT SOUND RATED WALLS.
J. PROVIDE SPECIFIED TILE BACKER BOARD AT ALL WALLS
INDICATED TO HAVE CERAMIC TILE, REFER TO FINISH
PLANS.
K. ISOLATE NON-LOAD-BEARING STUD FRAMING FROM
BUILDING STRUCTURE TO PREVENT TRANSFER OF
VERTICAL LOADS WHILE PROVIDING LATERAL SUPPORT AS
SPECIFIED.
L. WOOD OR METAL STUD SPACING SHALL BE 16”ON CENTER
MAXIMUM UNLESS OTHERWISE REQUIRED BY DELEGATED
DESIGN OR NOTED OTHERWISE.
SHEET TITLE
SHEET NUMBER
Kite Realty Group
30 S. Meridian Street, #1100
Indianapolis, Indiana 46204
Owner
Republic Airways Holdings
RATIO
101 South Pennsylvania Street
Indianapolis, Indiana 46204
317-633-4040
Architect
McComas/O'donnell & Naccarato
Structural Engineer
Mechanical / Plumbing Design/Builder
Civil Engineer
8909 Purdue Road, Suite 300
Indianapolis, Indiana 46268
1717 E. 116th Street, Suite 200
Carmel, Indiana 46032
317-580-0402
DEEM LLC
6831 E 32nd Street
Indianapolis, Indiana 46226
Kimley Horn
250 East 96th Street, Suite 580
Indianapolis, Indiana 46240
PROJECT NO.
SHEET ISSUE
NOT FOR CONSTRUCTION
SEAL | DATE
COPYRIGHT NOTICE: THIS ARCHITECTURAL
AND ENGINEERING DRAWING IS GIVEN IN
CONFIDENCE AND SHALL BE USED ONLY
PURSUANT TO THE AGREEMENT WITH RATIO.
NO OTHER USE, DISSEMINATION OR
DUPLICATION MAY BE MADE WITHOUT PRIOR
WRITTEN CONSENT OF RATIO. ALL COMMON
LAW RIGHTS OF COPYRIGHT AND OTHERWISE
ARE HEREBY SPECIFICALLY RESERVED.
Electrical Design/Builder
Barth Electric Co., Inc.
1934 N. Illinois Street
Indianapolis, Indiana 46202
10/29/2021 4:10:19 PMA-002
INTERIOR PARTITION
TYPES AND
STANDARD
PARTITION DETAILS
21040.000
Republic Airways
Hotel
12197 N Meridian St.
Carmel, IN 46032
INTERIOR PARTITION LEGEND
INTERIOR PARTITION HEIGHT CODES
INTERIOR PARTITION TYPES
STANDARD-DEVICE MOUNTING GUIDELINES
INTERIOR PARTITION NOTES
1 BID PACKAGE #1 08/30/21
2 DESIGN DEVELOPMENT 10/01/21
3 SHELL AND CORE PERMIT SET 10/15/21
10/15/21