Loading...
HomeMy WebLinkAboutA-131-FIRST FLOOR REFLECTED CEILING PLANGYB BOARD CEILING (REFER TO PLAN FOR SUSPENSION TYPE) ACOUSTIC CEILING TILE 2 x 4 LIGHT FIXTURE DOWNLIGHT MECHANICAL RETURN REGISTER MECHANICAL AIR SUPPLY DIFFUSER SPOT ELEVATION MARKER XXX-01 10'-10" A.F.F. CEILING TAG CEILING TYPE CEILING HEIGHT (ABOVE FINISH FLOOR) A. THESE GENERAL NOTES APPLY TO SERIES A-130 REFLECTED CEILING DRAWINGS. B. INSTALL NEW CEILINGS AT ▐►+9'-0”◄▌A.F.F. UNLESS NOTED OTHERWISE. ALL CEILINGS TO BE ▐►ACT-01 ◄▌UNLESS NOTED OTHERWISE. C. CENTER CEILING GRIDS WITHIN ROOMS EACH DIRECTION UNLESS NOTED OTHERWISE. D. LOCATE CEILING GRIDS WITHIN ROOMS SUCH THAT BORDERS CONTAIN NOT LESS THAN 1/2 TILE WIDTH, UNLESS OTHERWISE INDICATED. E. CENTER PENETRATIONS IN ACOUSTICAL CEILING SYSTEMS WITHIN INDIVIDUAL CEILING PANELS, SUCH AS SPRINKLER HEADS, DIFFUSERS, LIGHT FIXTURES, ETC., UNLESS OTHERWISE INDICATED. F. PAINT EXPOSED GYPSUM BOARD AND PLASTER CEILING SURFACES ▐►PT-XX◄▌UNLESS OTHERWISE INDICATED. G. PROVIDE CONTROL JOINTS (C.J.) IN GYPSUM BOARD CEILING CONSTRUCTION AS INDICATED. WHERE NOT SHOWN, PROVIDE MAXIMUM SPACING BETWEEN JOINTS OF 30'-0”. VERIFY FINAL CONTROL JOINT LOCATIONS WITH ARCHITECT PRIOR TO STARTING WORK WHETHER OR NOT INDICATED ON THE DRAWINGS. H. CEILING ACCESS PANELS INDICATED ARE NOT INTENDED TO LIMIT NUMBER OF PANELS REQUIRED. PANEL QUANTITY SHALL BE SUFFICIENT TO PROVIDE REQUIRED ACCESS WHETHER OR NOT INDICATED ON THE DRAWINGS. VERIFY FINAL LOCATIONS WITH ARCHITECT PRIOR TO STARTING WORK. I. REFER TO ▐►SERIES A-001◄▌GENERAL INFORMATION DRAWINGS FOR MATERIAL SYMBOL KEY. J. REFER TO ▐►SERIES A-150◄▌FINISH PLANS FOR ADDITIONAL CEILING FINISH INFORMATION. K. REFER TO ELECTRICAL DRAWINGS FOR CEILING-MOUNTED LIGHT FIXTURE TYPES AND QUANTITIES. L. REFER TO MECHANICAL DRAWINGS FOR CEILING-MOUNTED DIFFUSERS, GRILLE TYPES AND QUANTITIES. M. REFER TO FIRE PROTECTION DRAWINGS FOR SPRINKLER HEAD TYPES AND QUANTITIES. HEADS HAVE BEEN INTENTIONALLY OMITTED FROM REFLECTED CEILING PLANS FOR CLARITY. N. INSTALLATION OF CEILING SYSTEMS SHALL NOT BEGIN PRIOR TO SUBMITTAL AND REVIEW OF CEILING COORDINATION DRAWINGS SHOWING LAYOUT OF CEILING GRIDS OR CONTROL JOINTS AND ITEMS TO BE INSTALLED IN OR ON CEILINGS SUCH AS SPRINKLER HEADS, DIFFUSERS, GRILLES, LIGHT FIXTURES, FIRE DETECTION AND ALARM DEVICES, ACCESS PANELS, ETC. O. PROVIDE ▐►4" AXIOM EDGE TRIM◄▌ON ALL EXPOSED EDGES OF CEILINGS UNLESS NOTED OTHERWISE. P. IN AREAS WHERE STRUCTURE IS EXPOSED, CONTRACTOR TO PROVIDE FANAL LAYOUTS OF ALL DUCTWORK, PIPING, CONDUIT, LIGHTING, ETC. FOR FINAL APPROVAL BY ARCHITECT PRIOR TO INSTALLATION. Q. PAINT ALL ELEMENTS ABOVE CLOUD CEILINGS WITHIN 6'-0" OF PERIMETER INCLUDING BUT NOT LIMITED TO DUCTWORK, STRUCTURE, CABLES, METAL STUDS, PIPING, CEILING HANGERS, AND MECHANICAL DEVICES A A B B C C D D E E F F G G 1 1 2 2 3 3 A.2 A.2 4 4 5 5 6 6 1.2 1.2 B.1 B.1 B.9 B.9 7 7 8 8 A.1 A.1 GWB-X1 12'-0" A.F.F. GWB-01 9'-6" A.F.F.GWB-01 9'-6" A.F.F. ACT-XX 12'-0" A.F.F. ACT-XX 12'-0" A.F.F. ACT-XX 12'-0" A.F.F.ACT-XX 12'-0" A.F.F. ACT-XX 12'-0" A.F.F. ACT-XX 12'-0" A.F.F. ACT-XX 12'-0" A.F.F. ACT-XX 12'-0" A.F.F. EXP EXST. GYP. 9'-6" A.F.F. EXST. GYP. 9'-6" A.F.F. KITCHEN 132 ELECTRICAL 133 LAUNDRY/LINEN 134 HOUSEKEEPING 140 EMPLOYEE LOUNGE 142 FITNESS 143 STORAGE 138 OFFICE 141 PUMP ROOM 137 MECHANICAL 139 STAIR 2 RECEIVING PAD 136 ELEV. EQUIP 144 DINING 146 DINING 103 COLLABORATION 122 COLLABORATION 121 ELEV 137 ELEV 138 REC. CENTER 118 ELECTRICAL 117 MECHANICAL 114 GUEST LAUNDRY 113 REC. CENTER 112LUGGAGE STORAGE 107 VESTIBULE 101 MEN 130 WOMEN 131 F.5F.5 F.7F.7 1.1 1.1 LOBBY 100 GROUP STUDY 106 YOGA STUDIO 145 ACT-XX 9'-6" A.F.F.ACT-XX 9'-6" A.F.F. ACT-XX 9'-6" A.F.F.ACT-XX 9'-6" A.F.F. ACT-XX 9'-6" A.F.F. S6A.D.1.A ACT-XX 9'-6" A.F.F. ACT-XX 9'-6" A.F.F. GWB-01 9'-6" A.F.F. GWB-01 9'-6" A.F.F. EXP EXP EXP ACT-XX 10'-1 1/4" A.F.F. DECORATIVE CEILING 12'-6" A.F.F. DECORATIVE CEILING 12'-6" A.F.F. EXP. EXP. ACT-XX 12'-0" A.F.F. WD 12'-0" A.F.F. OPEN TO ABOVE OPEN TO ABOVE OPEN TO ABOVE 9'-3"5'-1 11/16"GWB-01 9'-10" A.F.F. GWB-01 9'-10" A.F.F. S3C.AS3C.A S3C.A GWB-01 9'-10" A.F.F. GWB-X1 8'-6" A.F.F. TRASH/ RECYLING 135 8'-3 3/4"8'-9 3/8"10'-8 1/2"10'-0"10'-0"10'-0"10'-0"10'-0"4 SHEET TITLE SHEET NUMBER Kite Realty Group 30 S. Meridian Street, #1100 Indianapolis, Indiana 46204 Owner Republic Airways Holdings RATIO 101 South Pennsylvania Street Indianapolis, Indiana 46204 317-633-4040 Architect McComas/O'donnell & Naccarato Structural Engineer Mechanical / Plumbing Design/Builder Civil Engineer 8909 Purdue Road, Suite 300 Indianapolis, Indiana 46268 1717 E. 116th Street, Suite 200 Carmel, Indiana 46032 317-580-0402 DEEM LLC 6831 E 32nd Street Indianapolis, Indiana 46226 Kimley Horn 250 East 96th Street, Suite 580 Indianapolis, Indiana 46240 PROJECT NO. SHEET ISSUE NOT FOR CONSTRUCTION SEAL | DATE COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE, DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED. Electrical Design/Builder Barth Electric Co., Inc. 1934 N. Illinois Street Indianapolis, Indiana 46202 10/29/2021 4:11:34 PMA-131 FIRST FLOOR REFLECTED CEILING PLAN 21040.000 Republic Airways Hotel 12197 N Meridian St. Carmel, IN 46032 RCP LEGEND KEYNOTES (SPEC BASED) GENERAL CEILING PLAN NOTES KEYNOTES (ACTION/GENERAL) 3/32" = 1'-0"A-131 B1 FIRST LEVEL RCP 1 BID PACKAGE #1 08/30/21 2 DESIGN DEVELOPMENT 10/01/21 3 SHELL AND CORE PERMIT SET 10/15/21 4 10/29/21 ADDENDUM #1 10/29/21 10/29/21