HomeMy WebLinkAboutL-704 Site Details - General Site DevelopmentOwner
Mechanical / Plumbing Design / Builder
Civil Engineer
Architect
101 South Pennsylvania Street
Indianapolis, Indiana 46204
317-633-4040
RATIO
30 S. Meridian Street, #1100
Indianapolis, Indiana 46204
Kite Realty Group
Republic Airways
Corporate Campus
12197 N. Meridian St.
Carmel, Indiana 46032
Structural Engineer
1717 E 116th Street, Suite 200
Carmel, Indiana 46032
317-580-0402
McComas/O'donnell Naccarato
21040.000
6831 E 32nd Street
Indianapolis, Indiana 46226
DEEM LLC
250 East 96th Street, Suite 580
Indianapolis, Indiana 46240
Kimley Horn
8909 Purdue Road, Suite 300
Indianapolis, Indiana 46268
Republic Airways Holdings
Electrical Design/Builder
1934 N. Illinois Street
Indianapolis, Indiana 46202
Barth Electric Co., Inc.
SITE DETAILS -
GENERAL SITE
DEVELOPMENT
DETAIL | HANDRAIL POST (GROUND MOUNT)
3" 1'-0"
2"EQ.EQ.
312"Ø
CONCRETE PAVING APPLICATION:6" MIN.3'-0"C5
L-704
DETAIL
HANDRAIL POST
ESCUTCHEON PLATE
HANDRAIL (DASHED):
2" O.D. PIPE (SPEC. 055213)
SHAPE HANDRAIL POST TO
MATCH PROFILE OF HANDRAIL,
TYP.
HANDRAIL POST:
3 4" X 2" BAR STOCK
(SPEC. 055213)
FINISH GRADE
CONCRETE PAVING PER PLANS
AND DETAILS; THICKEN AS
REQ'D FOR MIN. HANDRAIL
EMBEDMENT
FILL CORE-DRILLED HOLE
COMPLETELY W/ NON-SHRINK
GROUT
CONCRETE PAVING FOR UNIT
PAVER SUBSTRATE; THICKEN
AS REQ'D FOR MIN. HANDRAIL
EMBEDMENT
CORE-DRILLED HOLE
L-704 P-21040-23
A5
ARCHITECTURAL PRECAST TREAD APPLICATION:
DETAIL | HANDRAIL POST (GROUND MOUNT)
3" 1'-0"8"34"VARIES3'-0"6" MIN.312"Ø
C5
L-704
DETAIL
HANDRAIL POST
ESCUTCHEON PLATE
2"EQ.EQ.
FINISH GRADE
ARCHITECTURAL PRECAST
CONCRETE TREAD PER STAIR
DETAILS
CORE-DRILLED HOLE
HANDRAIL (DASHED):
2" O.D. PIPE (SPEC. 055213)
SHAPE HANDRAIL POST TO
MATCH PROFILE OF HANDRAIL,
TYP.
HANDRAIL POST:
3 4" X 2" BAR STOCK
(SPEC. 055213)
FILL CORE-DRILLED HOLE
COMPLETELY W/ NON-SHRINK
GROUT
MORTAR SETTING BED
CONCRETE SUBSTRATE W/
THICKENED EDGE, TYP. (SEE
PLANS)
L-704 P-21040-22
A3ELEVATION | ONE-RISER HANDRAIL
1" 1'-0"
1'-0"
VARIES
VARIES34"3 4"3'-0"VARIESHANDRAIL POST:
3 4" X 2" BAR STOCK
(SPEC. 055213)VARIES,SEE PLANSFINISH GRADE
HANDRAIL:
2" O.D. PIPE
(SPEC. 055213)
MITER JOINT
SHAPE HANDRAIL POST TO
MATCH PROFILE OF HANDRAIL,
TYP.
PRECAST TREAD AND UNIT PAVING APPLICATION:14"C3
L-704
DETAIL
HANDRAIL POST
(GROUND MOUNT)
A3
L-704
DETAIL
HANDRAIL POST
(GROUND MOUNT)
L-704 P-21040-31
A1
PLAN:
SECTION 'A-A':
A A
NOTES:
1.SET ESCUTCHEON PLATE ON
SILICONE ADHESIVE BASE.
2.SUBMIT COMPLETE SHOP
DRAWINGS FOR REVIEW PER
SPEC. 055213.
DETAIL | HANDRAIL POST ESCUTCHEON PLATE
6" 1'-0"
1116"
CL
15 16"
R2"
1116"1116"15 16"15 16"78"1916"1916"4"2"2"
4"
1116"15 16"
R2"HANDRAIL POST PER
ELEVATIONS AND DETAILS
HANDRAIL POST PER
ELEVATIONS AND DETAILS
FINISH GRADE
PAVING OR STAIR TREAD
SUBSTRATE PER PLANS AND
DETAILS
NON-SHRINK GROUT PER
HANDRAIL EMBEDMENT
DETAILS
JOINT SEALANT (CLEAR), TYP.
3 12"Ø CORE DRILL HOLE
14" X 4"Ø ESCUTCHEON PLATE
(SPEC. 055213)
14" X 4"Ø ESCUTCHEON PLATE
(SPEC. 055213)
3 12"Ø CORE DRILL HOLE
L-704 P-21040-26
C5
DETAIL | HANDRAIL POST (GROUND MOUNT)
3" 1'-0"
2"EQ.EQ.
312"Ø
UNIT PAVING BITUMINUOUS SETTING BED APPLICATION:
NOTE:
THIS DETAIL ASSUMES THAT
UNIT PAVING IS INSTALLED
PRIOR TO HANDRAIL. REFER
TO FOR ALTERNATE
DETAIL.
C1 L-704
C5
L-704
DETAIL
HANDRAIL POST
ESCUTCHEON PLATE
FINISH GRADE
HANDRAIL (DASHED):
2" O.D. PIPE (SPEC. 055213)
SHAPE HANDRAIL POST TO
MATCH PROFILE OF HANDRAIL,
TYP.
HANDRAIL POST:
3 4" X 2" BAR STOCK
(SPEC. 055213)
UNIT PAVING PER PLANS AND
DETAILS
CORE-DRILLED
HOLE
FILL CORE-DRILLED HOLE
COMPLETELY W/ NON-SHRINK
GROUT
BITUMINOUS SETTING BED
CONCRETE PAVING FOR UNIT
PAVER SUBSTRATE; THICKEN
AS REQ'D FOR MIN. HANDRAIL
EMBEDMENT3"9 34" MIN.3'-0"34"6" MIN.L-704 P-21040-25
C3DETAIL | HANDRAIL POST (GROUND MOUNT)
3" 1'-0"
2"EQ.EQ.
312"Ø
UNIT PAVING BITUMINUOUS SETTING BED APPLICATION:
NOTE:
THIS DETAIL ASSUMES THAT
UNIT PAVING IS INSTALLED
AFTER THE HANDRAIL. REFER
TO FOR ALTERNATE
DETAIL.
C3 L-704
C5
L-704
DETAIL
HANDRAIL POST
ESCUTCHEON PLATE
HANDRAIL (DASHED):
2" O.D. PIPE (SPEC. 055213)
SHAPE HANDRAIL POST TO
MATCH PROFILE OF HANDRAIL,
TYP.
HANDRAIL POST:
3 4" X 2" BAR STOCK
(SPEC. 055213)3"9 34" MIN.3'-0"34"6" MIN.FINISH GRADE
UNIT PAVING PER PLANS AND
DETAILS
CORE-DRILLED
HOLE
BITUMINOUS SETTING BED
CONCRETE PAVING FOR UNIT
PAVER SUBSTRATE; THICKEN
AS REQ'D FOR MIN. HANDRAIL
EMBEDMENT
FILL CORE-DRILLED
HOLE COMPLETELY W/
NON-SHRINK GROUT
3 12" I.D. X 18" TYPE 304 S.S. PIPE
3 16" TYPE 304 S.S. PLATE W/
CENTER HOLE
(4) 4" X 3 8"Ø S.S. EXPANSION
ANCHORS
4"4"
L-704 P-21040-24
C1
PRECAST TREAD AND UNIT PAVING APPLICATION:
ELEVATION | MULTI-RISER HANDRAIL
1" 1'-0"
1'-0"
VARIES
VARIES34"3 4"3'-0"VARIESHANDRAIL POST:
3 4" X 2" BAR STOCK
(SPEC. 055213)VARIES,SEE PLANSFINISH GRADE
HANDRAIL:
2" O.D. PIPE
(SPEC. 055213)
MITER JOINT, TYP.
SHAPE HANDRAIL POST TO
MATCH PROFILE OF HANDRAIL,
TYP.14"C3
L-704
DETAIL
HANDRAIL POST
(GROUND MOUNT)
A3
L-704
DETAIL
HANDRAIL POST
(GROUND MOUNT)
1 TREAD DEPTH
A6
P-21040-142L-704
2
1'-0" MIN.
VARIES
VARIES34"3 4"3'-0"VARIESHANDRAIL POST:
3 4" X 2" BAR STOCK
(SPEC. 055213)
FINISH GRADE
HANDRAIL:
2" O.D. PIPE
(SPEC. 055213)
MITER JOINT, TYP.
SHAPE HANDRAIL POST TO
MATCH PROFILE OF HANDRAIL,
TYP.
PRECAST TREAD AND UNIT PAVING APPLICATION:
C3
L-704
DETAIL
HANDRAIL POST
(GROUND MOUNT)
ELEVATION | ACCESSIBLE RAMP HANDRAIL
1" 1'-0"14"A5
L-704
DETAIL
HANDRAIL POST
(GROUND MOUNT)
1'-0" MIN.
E4
P-21040-143L-704
COPYRIGHT NOTICE: THIS ARCHITECTURAL
AND ENGINEERING DRAWING IS GIVEN IN
CONFIDENCE AND SHALL BE USED ONLY
PURSUANT TO THE AGREEMENT WITH RATIO.
NO OTHER USE, DISSEMINATION OR
DUPLICATION MAY BE MADE WITHOUT PRIOR
WRITTEN CONSENT OF RATIO. ALL COMMON
LAW RIGHTS OF COPYRIGHT AND OTHERWISE
ARE HEREBY SPECIFICALLY RESERVED.
SHEET TITLE
SHEET NUMBER
KEY PLAN
SHEET ISSUE
N
PROJECT NO.
SEAL | DATE
L-704
1 PERMIT SET 11/19/21
2 CD SET 12/17/21