Loading...
HomeMy WebLinkAboutL-704 Site Details - General Site DevelopmentOwner Mechanical / Plumbing Design / Builder Civil Engineer Architect 101 South Pennsylvania Street Indianapolis, Indiana 46204 317-633-4040 RATIO 30 S. Meridian Street, #1100 Indianapolis, Indiana 46204 Kite Realty Group Republic Airways Corporate Campus 12197 N. Meridian St. Carmel, Indiana 46032 Structural Engineer 1717 E 116th Street, Suite 200 Carmel, Indiana 46032 317-580-0402 McComas/O'donnell Naccarato 21040.000 6831 E 32nd Street Indianapolis, Indiana 46226 DEEM LLC 250 East 96th Street, Suite 580 Indianapolis, Indiana 46240 Kimley Horn 8909 Purdue Road, Suite 300 Indianapolis, Indiana 46268 Republic Airways Holdings Electrical Design/Builder 1934 N. Illinois Street Indianapolis, Indiana 46202 Barth Electric Co., Inc. SITE DETAILS - GENERAL SITE DEVELOPMENT DETAIL | HANDRAIL POST (GROUND MOUNT) 3" 1'-0" 2"EQ.EQ. 312"Ø CONCRETE PAVING APPLICATION:6" MIN.3'-0"C5 L-704 DETAIL HANDRAIL POST ESCUTCHEON PLATE HANDRAIL (DASHED): 2" O.D. PIPE (SPEC. 055213) SHAPE HANDRAIL POST TO MATCH PROFILE OF HANDRAIL, TYP. HANDRAIL POST: 3 4" X 2" BAR STOCK (SPEC. 055213) FINISH GRADE CONCRETE PAVING PER PLANS AND DETAILS; THICKEN AS REQ'D FOR MIN. HANDRAIL EMBEDMENT FILL CORE-DRILLED HOLE COMPLETELY W/ NON-SHRINK GROUT CONCRETE PAVING FOR UNIT PAVER SUBSTRATE; THICKEN AS REQ'D FOR MIN. HANDRAIL EMBEDMENT CORE-DRILLED HOLE L-704 P-21040-23 A5 ARCHITECTURAL PRECAST TREAD APPLICATION: DETAIL | HANDRAIL POST (GROUND MOUNT) 3" 1'-0"8"34"VARIES3'-0"6" MIN.312"Ø C5 L-704 DETAIL HANDRAIL POST ESCUTCHEON PLATE 2"EQ.EQ. FINISH GRADE ARCHITECTURAL PRECAST CONCRETE TREAD PER STAIR DETAILS CORE-DRILLED HOLE HANDRAIL (DASHED): 2" O.D. PIPE (SPEC. 055213) SHAPE HANDRAIL POST TO MATCH PROFILE OF HANDRAIL, TYP. HANDRAIL POST: 3 4" X 2" BAR STOCK (SPEC. 055213) FILL CORE-DRILLED HOLE COMPLETELY W/ NON-SHRINK GROUT MORTAR SETTING BED CONCRETE SUBSTRATE W/ THICKENED EDGE, TYP. (SEE PLANS) L-704 P-21040-22 A3ELEVATION | ONE-RISER HANDRAIL 1" 1'-0" 1'-0" VARIES VARIES34"3 4"3'-0"VARIESHANDRAIL POST: 3 4" X 2" BAR STOCK (SPEC. 055213)VARIES,SEE PLANSFINISH GRADE HANDRAIL: 2" O.D. PIPE (SPEC. 055213) MITER JOINT SHAPE HANDRAIL POST TO MATCH PROFILE OF HANDRAIL, TYP. PRECAST TREAD AND UNIT PAVING APPLICATION:14"C3 L-704 DETAIL HANDRAIL POST (GROUND MOUNT) A3 L-704 DETAIL HANDRAIL POST (GROUND MOUNT) L-704 P-21040-31 A1 PLAN: SECTION 'A-A': A A NOTES: 1.SET ESCUTCHEON PLATE ON SILICONE ADHESIVE BASE. 2.SUBMIT COMPLETE SHOP DRAWINGS FOR REVIEW PER SPEC. 055213. DETAIL | HANDRAIL POST ESCUTCHEON PLATE 6" 1'-0" 1116" CL 15 16" R2" 1116"1116"15 16"15 16"78"1916"1916"4"2"2" 4" 1116"15 16" R2"HANDRAIL POST PER ELEVATIONS AND DETAILS HANDRAIL POST PER ELEVATIONS AND DETAILS FINISH GRADE PAVING OR STAIR TREAD SUBSTRATE PER PLANS AND DETAILS NON-SHRINK GROUT PER HANDRAIL EMBEDMENT DETAILS JOINT SEALANT (CLEAR), TYP. 3 12"Ø CORE DRILL HOLE 14" X 4"Ø ESCUTCHEON PLATE (SPEC. 055213) 14" X 4"Ø ESCUTCHEON PLATE (SPEC. 055213) 3 12"Ø CORE DRILL HOLE L-704 P-21040-26 C5 DETAIL | HANDRAIL POST (GROUND MOUNT) 3" 1'-0" 2"EQ.EQ. 312"Ø UNIT PAVING BITUMINUOUS SETTING BED APPLICATION: NOTE: THIS DETAIL ASSUMES THAT UNIT PAVING IS INSTALLED PRIOR TO HANDRAIL. REFER TO FOR ALTERNATE DETAIL. C1 L-704 C5 L-704 DETAIL HANDRAIL POST ESCUTCHEON PLATE FINISH GRADE HANDRAIL (DASHED): 2" O.D. PIPE (SPEC. 055213) SHAPE HANDRAIL POST TO MATCH PROFILE OF HANDRAIL, TYP. HANDRAIL POST: 3 4" X 2" BAR STOCK (SPEC. 055213) UNIT PAVING PER PLANS AND DETAILS CORE-DRILLED HOLE FILL CORE-DRILLED HOLE COMPLETELY W/ NON-SHRINK GROUT BITUMINOUS SETTING BED CONCRETE PAVING FOR UNIT PAVER SUBSTRATE; THICKEN AS REQ'D FOR MIN. HANDRAIL EMBEDMENT3"9 34" MIN.3'-0"34"6" MIN.L-704 P-21040-25 C3DETAIL | HANDRAIL POST (GROUND MOUNT) 3" 1'-0" 2"EQ.EQ. 312"Ø UNIT PAVING BITUMINUOUS SETTING BED APPLICATION: NOTE: THIS DETAIL ASSUMES THAT UNIT PAVING IS INSTALLED AFTER THE HANDRAIL. REFER TO FOR ALTERNATE DETAIL. C3 L-704 C5 L-704 DETAIL HANDRAIL POST ESCUTCHEON PLATE HANDRAIL (DASHED): 2" O.D. PIPE (SPEC. 055213) SHAPE HANDRAIL POST TO MATCH PROFILE OF HANDRAIL, TYP. HANDRAIL POST: 3 4" X 2" BAR STOCK (SPEC. 055213)3"9 34" MIN.3'-0"34"6" MIN.FINISH GRADE UNIT PAVING PER PLANS AND DETAILS CORE-DRILLED HOLE BITUMINOUS SETTING BED CONCRETE PAVING FOR UNIT PAVER SUBSTRATE; THICKEN AS REQ'D FOR MIN. HANDRAIL EMBEDMENT FILL CORE-DRILLED HOLE COMPLETELY W/ NON-SHRINK GROUT 3 12" I.D. X 18" TYPE 304 S.S. PIPE 3 16" TYPE 304 S.S. PLATE W/ CENTER HOLE (4) 4" X 3 8"Ø S.S. EXPANSION ANCHORS 4"4" L-704 P-21040-24 C1 PRECAST TREAD AND UNIT PAVING APPLICATION: ELEVATION | MULTI-RISER HANDRAIL 1" 1'-0" 1'-0" VARIES VARIES34"3 4"3'-0"VARIESHANDRAIL POST: 3 4" X 2" BAR STOCK (SPEC. 055213)VARIES,SEE PLANSFINISH GRADE HANDRAIL: 2" O.D. PIPE (SPEC. 055213) MITER JOINT, TYP. SHAPE HANDRAIL POST TO MATCH PROFILE OF HANDRAIL, TYP.14"C3 L-704 DETAIL HANDRAIL POST (GROUND MOUNT) A3 L-704 DETAIL HANDRAIL POST (GROUND MOUNT) 1 TREAD DEPTH A6 P-21040-142L-704 2 1'-0" MIN. VARIES VARIES34"3 4"3'-0"VARIESHANDRAIL POST: 3 4" X 2" BAR STOCK (SPEC. 055213) FINISH GRADE HANDRAIL: 2" O.D. PIPE (SPEC. 055213) MITER JOINT, TYP. SHAPE HANDRAIL POST TO MATCH PROFILE OF HANDRAIL, TYP. PRECAST TREAD AND UNIT PAVING APPLICATION: C3 L-704 DETAIL HANDRAIL POST (GROUND MOUNT) ELEVATION | ACCESSIBLE RAMP HANDRAIL 1" 1'-0"14"A5 L-704 DETAIL HANDRAIL POST (GROUND MOUNT) 1'-0" MIN. E4 P-21040-143L-704 COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE, DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED. SHEET TITLE SHEET NUMBER KEY PLAN SHEET ISSUE N PROJECT NO. SEAL | DATE L-704 1 PERMIT SET 11/19/21 2 CD SET 12/17/21