fo/1-sty brick strip mall16,028 SqFttinv:852.60exist curb inlettr:857.00inv(w):855.0212" rcpinv:852.27exist curb inlettr:857.14inv(w):852.53inv(e):852.5712" rcpexist drainage inlettr:858.77inv(w):853.27inv(ne):855.82inv(e):853.3212" rcpinv:852.56exist curb inlettr:858.28inv(w):853.20inv(se):853.2215" rcpexist drainage inlettr:859.66inv(nw):854.56inv(s):854.5615" rcpinv:854.45exist drainage inlettr:858.54inv(se):855.86inv(n):856.1215" rcpdirection only10" pvc
exist sanitary mhtr:857.88inv(n):851.47inv(s):851.53inv(sw):851.998" pvcexist sanitary mhtr:859.31inv(n):852.51inv(s):852.618" pvc
exist sanitary mhtr:862.30inv(n):853.40inv(sw):853.508" pvc direction only8"
pvcdirection onlycappedexist curb inlettr:857.61inv(s):854.59inv(n):854.3712" rcp
exist curb inlettr:856.80inv(s):853.88inv(n):853.70inv(e):852.8515" rcp
directiononly12" rcpdirectiononly8" cpp
exist drainage inlettr:858.54inv(w):854.14inv(e):854.3412" rcpinv:854.44w/ces12" rcpfrombldgexist curb inlettr:858.71inv(w):855.96inv(e):855.9610" pvcexist curb inlettr:858.21inv(w):855.16inv(e):855.1612" rcpinv:854.49w/ces12" rcpFFE:861.89FFE:861.91FFE:860.66FFE:860.66FFE:861.72exist curb inlettr:861.81inv(n):856.11inv(e):856.1115" rcp
exist drainage inlettr:861.06inv(w):857.36inv(e):857.3612" rcpexist curb inlettr:861.01inv(w):858.6112" rcpexist curb inlettr:858.99inv(e):856.39exist curb inlettr:858.49inv(w):854.99inv(ne):854.9912" rcpinv:854.3312"
rcpexist drainage inlettr:860.86inv(w):857.66inv:856.83with concend section12" rcpexist curb inlettr:860.28inv(e):856.58exist curb inlettr:860.39inv(w):857.19inv(e):857.1912" rcp12" rcpexist sanitary mhtr:862.81inv(n):855.41exist grease mhtr:861.306" pvcdirection only8" pvc
exist sanitary mhtr:863.16inv(w):854.36inv(ne):854.268" pvcexist sanitary mhtr:862.42inv(sw):853.92inv(w):855.72inv(ne):853.828"
p
v
c exist clean outtr:862.048" pvc8"
pvcbuilding height:25.5'199.9'80.1'200.1'80.2'34.2'1.9'2.2'6.1'17.1'8.6'9.7'75.7'10.3'94.0'10.3'12.1'10.3'8.6'18.1'4.1'35.4'207.3'building height:25.4'FFE:861.9119.6'1.8'31.9'7.6'23.3'88.1'3.8'19.2'62.3'55.7'8.7'57.1'inv:859.4912" rcp 10.8'17.6'9.6'101.7'49.1'N90°00'00"E - 284.09'N00°00'00"EN90°00'00"E27.99'N00°00'00"E - 245.29'N00°03'57"W - 1186.40'
S00°07'31"E - 695.72'
46.53'S88°46'31"W - 226.41'KRG Hamilton Crossing, LLCInst. No. 2004-59877KRG Hamilton Crossing, LLCInst. No. 2004-59877North Meridian Carmel Hotel, L.P.Inst. No. 2004-27998Utility Easement
Bk 269, Pg 267Utility EasementInst. No. 99-29602Utility EasementInst. No. 99-72494Lease Access
Road Easement
Inst. No. 2001-5902Drainage EasementInst. No. 2001-5902Parking Easement Area "A"Inst. No. 2001-5902 Parking Easement Area "B"Inst. No. 2001-5902
Drainage EasementInst. No. 2001-5902Drainage EasementInst. No. 2001-5902Utility EasementInst. No. 99-72494Utility Easement
Inst. No. 99-72494 & Inst. No.
99-29602Drainage EasementInst. No. 2001-590245'Half R/W14.8'110.6'87.3'Southern Boundary of 110 Acre Parcel describedin the Real Estate Covenant recorded in Misc.Rec. 166, Page 545Access DriveInst. No. 2001-5902Inst. No. 2004-27997Access DriveInst. No. 2001-5902Inst. No. 2004-27997
Utility Easement
Bk 271, Pg 383
Drainage EasementInst. No. 2007070119
Sign subject to"Consent to Encroach"Inst. No. 2014-49087PENNSYLVANIA AVE
w
w
w w w
OwnerMechanical / Plumbing Design / BuilderCivil EngineerArchitect101 South Pennsylvania StreetIndianapolis, Indiana 46204317-633-4040RATIO30 S. Meridian Street, #1100Indianapolis, Indiana 46204Kite Realty GroupRepublic AirwaysCorporate Campus12197 N. Meridian St.Carmel, Indiana 46032Structural Engineer1717 E 116th Street, Suite 200Carmel, Indiana 46032317-580-0402McComas/O'donnell Naccarato21040.0006831 E 32nd StreetIndianapolis, Indiana 46226DEEM LLC250 East 96th Street, Suite 580Indianapolis, Indiana 46240Kimley Horn8909 Purdue Road, Suite 300Indianapolis, Indiana 46268Republic Airways HoldingsElectrical Design/Builder1934 N. Illinois StreetIndianapolis, Indiana 46202Barth Electric Co., Inc.SCALE015'30'60'A1L-401GRADING PLAN - PHASE IGRADING PLAN -PHASE IGENERAL NOTES | SITE GRADING PLANS:1.WORK SHOWN ON THE DRAWINGS SHALL BE BASE BID UNLESS SPECIFICALLY NOTED TO BE BY ALTERNATE BID.2.COORDINATE ALL WORK WITH OTHER DESIGN DISCIPLINES.3.CONTRACTOR SHALL VERIFY ALL VERTICAL AND HORIZONTAL DIMENSIONS AND FIELD CONDITIONS PRIOR TOSTARTING WORK. CONTRACTOR IS RESPONSIBLE FOR ALL FIELD DIMENSIONS. IF CONTRACTOR FINDS ANYDISCREPANCIES BETWEEN CONTRACT DOCUMENTS AND ACTUAL FIELD DIMENSIONS OR CONDITIONS,CONTRACTOR SHALL NOTIFY LANDSCAPE ARCHITECT IMMEDIATELY.4.PARTICIPATE IN THE PRE-INSTALLATION CONFERENCE FOR THE GRADING AND DRAINAGE SCOPE OF THEWORK, ACCORDING TO THE PROJECT SPECIFICATIONS, PRIOR TO COMMENCEMENT.5.EXISTING AND PROPOSED UTILITIES THAT ARE SHOWN ARE FOR REFERENCE ONLY. REFER TO THE SITESURVEY FOR EXISTING UTILITIES AND VERIFY ALL IN THE FIELD. REFER TO AND COORDINATE WITH DRAWINGSPREPARED BY OTHER DESIGN DISCIPLINES FOR ALL PROPOSED UTILITIES.6.TYPICAL MAXIMUM SIDEWALK CROSS SLOPES ARE 2% (1/4" PER 1'-0"). TYPICAL MAXIMUM SIDEWALK RUNNINGSLOPES ARE 5% (1'-0" PER 20'-0").7.WHERE NEW PAVED SURFACES ADJOIN EXISTING PAVED SURFACES, MEET EXISTING GRADE.8.DRAINAGE DESIGN SHOWN IS CONCEPTUAL. PLEASE SEE CIVIL DRAWINGS FOR MORE COMPLETE ANDDETAILED STORMWATER DRAINAGE DESIGN.9.CURB RAMPS SHALL COMPLY WITH CURB RAMP DRAWING INDEX & GENERAL NOTES (REF: ).10.SPOT ELEVATIONS ARE DENOTED AS FOLLOWS:SPOT ELEVATION - EXISTING:SPOT ELEVATION - PROPOSED:11.SPOT ELEVATION ABBREVIATIONS ARE DEFINED AS FOLLOWS:BC = BOTTOM OF CURBBR = BOTTOM OF RAMPBS = BOTTOM OF STAIRBW = BOTTOM OF WALLFG = FINISH GRADERIM = TOP OF CASTINGTC = TOP OF CURBTEP = TOP OF EQUIPMENT PADTP = TOP OF PAVINGTR = TOP OF RAMPTS = TOP OF STAIRTSC = TOP OF STONE CURBTW = TOP OF WALL000.00 TP000.00 TPMATCHLINE - FUTURE PHASESEXISTING HOTELF.F.E. = 862.40FUTURE PARKING GARAGENOT INCLUDED IN PHASE IF.F.E. = 862.00PROPOSEDTRAINING CENTERF.F.E. = 862.40PROPOSEDHEADQUARTERS BUILDINGNOT INCLUDED IN PHASE IF.F.E. = TBDPROPOSED HOTEL EXPANSIONF.F.E. = 862.40A1L-641A1L-643A1L-642A1L-644FUTURE STREETSCAPE (WALKS, TREES, STREETLIGHTS, ETC.)A1L-645COPYRIGHT NOTICE: THIS ARCHITECTURALAND ENGINEERING DRAWING IS GIVEN INCONFIDENCE AND SHALL BE USED ONLYPURSUANT TO THE AGREEMENT WITH RATIO.NO OTHER USE, DISSEMINATION ORDUPLICATION MAY BE MADE WITHOUT PRIORWRITTEN CONSENT OF RATIO. ALL COMMONLAW RIGHTS OF COPYRIGHT AND OTHERWISEARE HEREBY SPECIFICALLY RESERVED.SHEET TITLESHEET NUMBERKEY PLANSHEET ISSUENPROJECT NO.SEAL | DATEL-4011PERMIT SET11/19/212CD SET12/17/213BULLETIN SET 402/04/223