HomeMy WebLinkAbout06100040 Site Plan
L ~ \ ~~~:-Im7
~ ...JI' 317-826-71110
Sctvl8ider ' 317-828-7200 FAX
!his Plot film Prepcnd For: "/I Homes
Lot # 88, containingl0,799 S.F.:t, in
Heath. Knell
Section , 2
Instrument # 2006-00004470
PC 4 Slide 13
Coy Township, Homiton County
SEe 20, l1llN, ROJE
14445 UVlNGSTON LANE (50' R/W)
Westfield, IN 46074
Prepared Date: 09/28/06: By: KAG
Community Reslrictions:
Side Yard = 3' min.
Aggregate = 6' RH.
Zon;ng - SI
~/1 HOMES
Pod Grode = 917.8 per plan
Pod Grode + 0.2' = Goroge FIT (918.0 )
Goroge FIT + 0.5' = Resident;ol FIT (918.5 )
Resident;ol FIT - 9.0 ' = Basement FIT (909.5 )
Driveway Slope = 2.8%
z
0 ~ ~
f- " !i
(f) '"
~
"
C)
Z
>
-
--.J
30.0'
B-B
Note : The garage finished noor e1eYOtion
is 1.0' above the curb at the drive, per
pion.
GROUND COI,ffi CALCULA nONS:
Drive = 862 Sf t
Public Walk =319 Sft
Private Walk =N/A Sft
Seeding = 5,647 Sft
Sad =263 SYt,
from front of residence.
w
Z
<C
--.J
FLOOD HAZARD STATEMENT
CERTlFICA TION
"",\\\\\IIIIIIIII/i1Ii1III/,
~~ C. L. cJ/;~
iIf ~;)............ 'l'~J""
ff ~...tG\SNTt~~........"..o%
g<::::)....~ o. <>.... /0%
I { S0303 ' ~
% "STATE OF.. ~
~ /', ,,~
~ ~~>!.'YOj A~.!:"""~~
%'f/J .S....U..ii~,C'''#
~0'/1. 1\ , \.. ';..\~~
~llllill/l/llIll\\II\\\\\\~
~lr-v
Knci_"1
Su"'JlDl
Landmlpe Architect.ure
CIll.US
Ceoio&Y
Note:
This drawing is based on construction plans or record drawings,
and is not based lJpon 0 field survey. The Schneider Corporation
does not warrant the accuracy or sufficiency of this information.
Contractors should verify existing conditions prior to any
conslruction. Any discrepancy found on this drawing should be
reported to The Schneider Corporation immediately; Jailing to do
so results in the contractors assumption of all liability. I
Plot Plan Leqend
[]jj[Q] Proposed Grades
000.0 Existing Grades
__ 000.0-- Contour Grade
* Approx. Lateral Location
- a - Sanitary Sewer lines
- a, - Storm Sewer Lines
- 'J - Water Service Lines
- - - - - - - Sub-Surface Drain lines
. ~onhole (Sanitary or Stann)
. Beehi~ Inlet (St"'!")
IlIII Corb -Inlet (Stann)
D End Section (Storm)
.... Fire Hj<lron I
- ~ ~ ~ - ~ ~ ~ - Flow Line of swale
Building Line (BL / BSL)
- - - - - - - Easement line
LOT i 88
VB06.0062134
~
~
=~=
~
Assumed Norlh
Scale: I' = 30'
Deloa of'
Cround/Storm Water:
flow pottern of on
indiYiduollol
[QJ
-M-
-~-
-- - -
Note: Builder to
enSllre positive
drainage away
Irom slructure{s).
Note: Sanitary Sewer
Top of Costing Infonnation
Upstream ~onhole, TC= 918.06
Downstream ~onhole, TC= 917.24
per record drwg.
Note: The contractor is to maintain a
minimum dislonce of ten feel (10')
between the sanitary sewer and water
line laterals.
I
I
I
I
I
4.0' I
PER PlAN I
HK 730
TC=918.06
PER REC. OWG.
17.5
11.2" ~ I
;5 21.00 ;5
26.p' a a '" I~
.33' ~5! 29.33' '"
36.0 ~ ~I >i!! '" I '" I~
"'n :!l ~!i; ~ ~ b
> ~
i:; ~ I
Ii! 0
~ lllil~ 4.00' 0
::l-l "'~ I 0
!:!!~ co
~I f;1~Q !:I r51.3"
IX> ~ ~ ~I
V> i-
~I
I 35.61
8 L_____!______
9.3' 11.2"
917.0 1917.3 I
7.0' 135.00
26.0; 8 18.33
... ~
M'
~
~
E
al HK 728
TC=917.24
PER REC. OWG.
NOTE:
SU~P PU~P(S) TO BE PLACED
BY BUILDER AS NEEDED.
Note:
The basement elewtlan. depicted hll!f'8lln, has been detll'1'flined aid based on
the pod l70des ald/eI contours Loken from the construdlon ploos fel this
subdivision. Unless stated. no information about nuctuoting water tables, IO~
conditions. eI soi t)t)eS has been prlMded or stated on said plans. This lot
Is located neel' 0 body of water. lot or soi conditions moy rtlCJlire that the
basement Boor efevotion be hekl 2 fool 000ve normal pool elevation. Site
investiqation may be needed if water is encounhnd during the excowtion
process or If other known water elevation or 90is condItions ore present
In'l'eStigotion (lid any remedial procecklres is at the discretion of the buMer
to determine and take appropriate steps of action. If any ground water is
encountered dl.rng tJ:cowtlon the buider Is encouraged to conlacl The
Sd1neider Corporation to OlSCUSS possbIe courses of action. 4: 1 SLOPt
z
:i
.
o
I
"'-
4'.\ SLOP'"
TYPICAL SWALE SECTION
This drawing is not intended to be represented os 0 retrocement or
original boundary survey, 0 route survey, or 0 Surveyor Location Report.
nood Hozard Statement: The accuracy of any nood hazard dalo shown on
this plot pion is subject to mop scale uncertainty and to any other
uncertainty in location or elevation on the referenced nood insurance rote
mop (FlR~). None of the within descnbed land lies within lhot special "ood
hazard zone "A", os so;d land plots by scale on Community ~op Panel ,
18057C020Sf of the "ood ;nsuronce rote mops (FlRM) for Hamilton County,
Indiana, Doted ~ay 19, 1981.
NOT[: IN THE RESIDENTIAl DISTRICTS UMITING
HEIGHT TO TVlENTY-FlVE (25) FIET. A OYllliJNG
MAY BE INCREASED IN HEIGHT TO THiRTY-FlVE (35)
fEET PROI/1DED THE SlOE AND REAR YAROS ARE
INCREASED AN ADDITIONAl FOOT FOR EACH FOOT
SUCH STRUCTURE EXCEEDS TVlENTY-FlVE (25) fEET
IN HEIGHT. PER CARMEL ZONING ORDINANCE 26.1.1.