Loading...
HomeMy WebLinkAbout06100040 Site Plan L ~ \ ~~~:-Im7 ~ ...JI' 317-826-71110 Sctvl8ider ' 317-828-7200 FAX !his Plot film Prepcnd For: "/I Homes Lot # 88, containingl0,799 S.F.:t, in Heath. Knell Section , 2 Instrument # 2006-00004470 PC 4 Slide 13 Coy Township, Homiton County SEe 20, l1llN, ROJE 14445 UVlNGSTON LANE (50' R/W) Westfield, IN 46074 Prepared Date: 09/28/06: By: KAG Community Reslrictions: Side Yard = 3' min. Aggregate = 6' RH. Zon;ng - SI ~/1 HOMES Pod Grode = 917.8 per plan Pod Grode + 0.2' = Goroge FIT (918.0 ) Goroge FIT + 0.5' = Resident;ol FIT (918.5 ) Resident;ol FIT - 9.0 ' = Basement FIT (909.5 ) Driveway Slope = 2.8% z 0 ~ ~ f- " !i (f) '" ~ " C) Z > - --.J 30.0' B-B Note : The garage finished noor e1eYOtion is 1.0' above the curb at the drive, per pion. GROUND COI,ffi CALCULA nONS: Drive = 862 Sf t Public Walk =319 Sft Private Walk =N/A Sft Seeding = 5,647 Sft Sad =263 SYt, from front of residence. w Z <C --.J FLOOD HAZARD STATEMENT CERTlFICA TION "",\\\\\IIIIIIIII/i1Ii1III/, ~~ C. L. cJ/;~ iIf ~;)............ 'l'~J"" ff ~...tG\SNTt~~........"..o% g<::::)....~ o. <>.... /0% I { S0303 ' ~ % "STATE OF.. ~ ~ /', ,,~ ~ ~~>!.'YOj A~.!:"""~~ %'f/J .S....U..ii~,C'''# ~0'/1. 1\ , \.. ';..\~~ ~llllill/l/llIll\\II\\\\\\~ ~lr-v Knci_"1 Su"'JlDl Landmlpe Architect.ure CIll.US Ceoio&Y Note: This drawing is based on construction plans or record drawings, and is not based lJpon 0 field survey. The Schneider Corporation does not warrant the accuracy or sufficiency of this information. Contractors should verify existing conditions prior to any conslruction. Any discrepancy found on this drawing should be reported to The Schneider Corporation immediately; Jailing to do so results in the contractors assumption of all liability. I Plot Plan Leqend []jj[Q] Proposed Grades 000.0 Existing Grades __ 000.0-- Contour Grade * Approx. Lateral Location - a - Sanitary Sewer lines - a, - Storm Sewer Lines - 'J - Water Service Lines - - - - - - - Sub-Surface Drain lines . ~onhole (Sanitary or Stann) . Beehi~ Inlet (St"'!") IlIII Corb -Inlet (Stann) D End Section (Storm) .... Fire Hj<lron I - ~ ~ ~ - ~ ~ ~ - Flow Line of swale Building Line (BL / BSL) - - - - - - - Easement line LOT i 88 VB06.0062134 ~ ~ =~= ~ Assumed Norlh Scale: I' = 30' Deloa of' Cround/Storm Water: flow pottern of on indiYiduollol [QJ -M- -~- -- - - Note: Builder to enSllre positive drainage away Irom slructure{s). Note: Sanitary Sewer Top of Costing Infonnation Upstream ~onhole, TC= 918.06 Downstream ~onhole, TC= 917.24 per record drwg. Note: The contractor is to maintain a minimum dislonce of ten feel (10') between the sanitary sewer and water line laterals. I I I I I 4.0' I PER PlAN I HK 730 TC=918.06 PER REC. OWG. 17.5 11.2" ~ I ;5 21.00 ;5 26.p' a a '" I~ .33' ~5! 29.33' '" 36.0 ~ ~I >i!! '" I '" I~ "'n :!l ~!i; ~ ~ b > ~ i:; ~ I Ii! 0 ~ lllil~ 4.00' 0 ::l-l "'~ I 0 !:!!~ co ~I f;1~Q !:I r51.3" IX> ~ ~ ~I V> i- ~I I 35.61 8 L_____!______ 9.3' 11.2" 917.0 1917.3 I 7.0' 135.00 26.0; 8 18.33 ... ~ M' ~ ~ E al HK 728 TC=917.24 PER REC. OWG. NOTE: SU~P PU~P(S) TO BE PLACED BY BUILDER AS NEEDED. Note: The basement elewtlan. depicted hll!f'8lln, has been detll'1'flined aid based on the pod l70des ald/eI contours Loken from the construdlon ploos fel this subdivision. Unless stated. no information about nuctuoting water tables, IO~ conditions. eI soi t)t)eS has been prlMded or stated on said plans. This lot Is located neel' 0 body of water. lot or soi conditions moy rtlCJlire that the basement Boor efevotion be hekl 2 fool 000ve normal pool elevation. Site investiqation may be needed if water is encounhnd during the excowtion process or If other known water elevation or 90is condItions ore present In'l'eStigotion (lid any remedial procecklres is at the discretion of the buMer to determine and take appropriate steps of action. If any ground water is encountered dl.rng tJ:cowtlon the buider Is encouraged to conlacl The Sd1neider Corporation to OlSCUSS possbIe courses of action. 4: 1 SLOPt z :i . o I "'- 4'.\ SLOP'" TYPICAL SWALE SECTION This drawing is not intended to be represented os 0 retrocement or original boundary survey, 0 route survey, or 0 Surveyor Location Report. nood Hozard Statement: The accuracy of any nood hazard dalo shown on this plot pion is subject to mop scale uncertainty and to any other uncertainty in location or elevation on the referenced nood insurance rote mop (FlR~). None of the within descnbed land lies within lhot special "ood hazard zone "A", os so;d land plots by scale on Community ~op Panel , 18057C020Sf of the "ood ;nsuronce rote mops (FlRM) for Hamilton County, Indiana, Doted ~ay 19, 1981. NOT[: IN THE RESIDENTIAl DISTRICTS UMITING HEIGHT TO TVlENTY-FlVE (25) FIET. A OYllliJNG MAY BE INCREASED IN HEIGHT TO THiRTY-FlVE (35) fEET PROI/1DED THE SlOE AND REAR YAROS ARE INCREASED AN ADDITIONAl FOOT FOR EACH FOOT SUCH STRUCTURE EXCEEDS TVlENTY-FlVE (25) fEET IN HEIGHT. PER CARMEL ZONING ORDINANCE 26.1.1.