Loading...
HomeMy WebLinkAbout06090168 Signed Conditional ENCOMPASS NOTEPAD - 10/12/06 NOTES FOR: 06090168 BLDG 2 - PR DATE TIME NOTE TEXT 2006-10-12 09:06:50 --~------~ -------- ---------------------------------------- 1. Assuming No.2 SPF and a 40 lb. live load, a 2x10 floor joist at 16"o.c. may span 15'-5". Floor Joist may be overspanned in 10ft area. 2. Smoke alarms shall meet all requirements of the Indiana Residential Code, 2005 Edition throughout the structure. See attached. Signature: TOTAL LINES OF NOTES: 12 .PV/.kS PAGE I OPERATOR crniser ENCOMPASS NOTEPAD - 10/03/06 NOTES FOR: 06090168 BLDG 1 - PR DATE TIME NOTE TEXT PAGE 1 I OPERATOR ~--------- -------- ---------------------------------------- 2006-10-03 14:14:15 1. Please indicate on a site plan the location of the new addition and the setbacks from property lines. 2. Please indicate (shaded, maybe) the new walls being constructed. 3. Please indicate type, size and spacing of floor joist for upstairs addition. 4. Please label use of rooms and spaces. 5. I am not sure exactly what is taking place at this site, addltional items may be required for review. 6. Drawings are incomplete. cmiser TOTAL LINES OF NOTES: 13 2 r~