HomeMy WebLinkAbout06100064 State Release
'I Indian. Dopartment of Homeland Security !' .... "INDIANA--02! \S;;~of~~i~e FDN~~~:
, ~~~1~0~~:h;~~;0;~~~:~~l.:~4~EVIEW i ~ np P q i !TY;;eof,elease H m --
I Indianapolis, IN 46204 . .."(,,.~(~'!',v;~.:.JL; Stand""...__
I A~;ii';blc At '1Q;Jr local i.iCc(~~~-BrllI1Ch : Projec~ name
II To: Owner I Architect I EngIneer SUPPORT HOOSIER SAFETY I Brownstones 5 Buiidings
SRS Architects !
! Stuart R Shade 4184 Cs"ireeiaddre'ss-n.
( 716 Adams i 1011 S Guilford
\ Suite F ~---city .. ..-..."'.-..,. [mCou-nty'
! Carmel IN 46032. ; Carmel i HAMILTON
[~.~_~__~_~~.~.~.~~..~."__._~_~.~.~,~~.~.~:,~~.~,~.~~~~~~~~"~,~'__~_~__t_~_~~~~.~.,.,_..,..____.________._____..._._,,....,,"'__.., ,._.._.,.~,..,' "__,__"_.,_.",,,...._._.,, ,...".. ."""" "...__________________________1,.." ___ .___.,_____._mn.n.........._...,_.-',...,.___,...
The plans, spec:ific.atlons an.d application sllbmitted for the above referenced project ha\l6 beon reviewed for compliance with the applicable rules of
tt1e Fire Prevenliol1 and Building Safety Commission, The project is rele.:lsed for construction subject 10, but not necessadly limited to, the condiHons
listed below. THIS IS NOT A BUilDlNG PERMIT. All'required'local permIts and Hc.enseS'r11ust-beobt-ajned prior'tobeginnil'lg construction work:. All
construction wOIi< must be in full compliance with all applicable State rules, Any changes in the released plans andlor specifications,must be filed with
and released by thL5 Office before any worry is..:~!ter,~d. :'1ihis,':{el~,f!se m~-Y b~~fi<us~'~nde.d)er revoked if it is determir~ed,:to Q~j$fi~ed in en'or, in violation
of any rules of the Commission or if It is b?-?eq on, l()CO(teGt qr lq:suHl:,;ie,n1 ir.j!orl!1~!ion/.Thj~ release shall expire by_limitation,: and become null and
void, if the work authorized is not commencedJWlthjn ol1e.(1J'ye:~r from,th,e above,:dale; .
CONDITIONS: ' .
i..,....
I
I
I
,
Would you like to reduce your turnaround time?
El.ECTRONICALL Y FIl.E YOUR PROJECT WITH STATE OF INOlANA AT
eme24.7@dhs.state.ln.u5, Or VISIT OUR WEe SITE. AT www.ln.govldhs/osbc
........... m_..... ...-.......-.........-.- ;-- pc'ojec\",';:;.limber-'" -. .-. .. mr---Relea's'cciili"e"-"'!
E-Filed, No hal'd
CONSTRUCTION DESIGN RELEASE i 318125 copy will be mailed i 06/14/06 i
Slate Form 41191 (R9/5.98) ~.....,...,,,,,....,,-- ...'"n____m__m__n..._._~__...'-....__"n__._'_"......._.....~,,,.L.._~.-n_mn_m__m~.'''.. .. I
: Construction type- i Occupancy classlflcatlon !
Report Printed on: June 14,2006 ! V.B I R.3
!
- -'-"-'"'~i
,
-,
i
,
---1
i
,
Note :(A1A & A1Bl: In accordan('''€,:wilh the affidavit sworn under penalties of perjury in tr.e application for construction design release the plClns
and specifications liled in conjunction with this proJect shall comply with all of the applicable rules and laws of Fire Prevention and Bllilding Safety
Commission, Providing false informatiDn con!:ililules an act of peljury, which is a Class 0 felony punishable by a prison term and a fine up to $10,000.
In accordance with Section 19 of the G(~nerat Administrative Rules (675 lAC 12-6-19) a complete se1 of plans and specifications that conform
eKactly 10 the design th~l was released by the office of the slate building commissioner shall be maintained on the construction jobsile as well as a
copy of the design rele~se.
1D0309A
100309B
100321 C
1003210
100405A
1D1307C
5 BLOGS,
1. This project has been reviewed under 2005 Indiana Residential Code.
2. A townhouse is a Stngle-family dwelling unit constructed in a group of three or more attached
units separted by property lines in which each unit extends from foundation to roof and with open
space on at least two sides In accordance with Section R202, IRC(675 lAC 14-4-3).
Permitted openings between the garage and residence shail be equipped with solid wood. or solid
or honeycomb core steel' doors not less than 1-3/8 inches thick or 20-mrnute fire~rated doors in
accordance with Section R309.1, iRC (675 lAC 14-4.2).
Garages shall be separated from dweiling units and their attic areas by not less than 1/2-inch
gypsum board applied to the garage side of supporting structure and to the structure supporting the
separation in accordance with Section R309.2, IRC (675 lAC 14-4.2).
3. Porches, balconies,decks or raised fioor surfaces located more than 30 inches above the floor or
grade below shall have guardrails not less than 36 inches in height ',n accordance with Section
R312.1,IRC(67514-4-2)
Through penetrations of fire-resistive wall or floor/ceiling assemblies shall be in accordance with
Section R3213.1, IRC (675 lAC 14-4.2).
Membrane penetrations of fire-resistive wall or floor/ceiling assemblies shail be in accordance with
Sections R321.3.1 and R321.3.2, IRC (675 lAC 14-4.2).
Drains shall be provided around all foundations that enclose habitable or usable spaces iocated
below grade in accordance with Section R405, IRC (675 lAC 14-4.2).
Appliances having an ignition source shall be elevated such that the source of ignition is not less
than 18 inches above the floor in garages and In rooms or spaces that are not part of the liVing
Page 1/2
Would you like to reduce your turnaround time?
ELECTRONICAL.LY FILE YOUR PROJECT WITH STATE OF INDIANA AT
afile24..7@dhs.state.ln.us, Or VISIT OUR WEB SITE AT www.ln.gov/dhsfosbc
space that communicate with the garage in accordance with Section M1307.3, IRC (675 lAC 14-
4.2).
101501A Clothes dryer exhausts shall convey moisture to and terminate outdoors in accordance with Section
M1501, IRC (675 lAC 14-4.2).
1D1502A Vented range hoods shall discharge (0 the outdoors in accordance with Section M15021, IRC (675
lAC 14-4.2).
1018030 Chimney and vent connectors sllall have minimum clearances to combustibles in accordance with
Section M1803.3.4, IRC (675 lAC 14A.2).
102419C Accessible shutoff valves shall be installed in the fuel supply piping within 6 feet of, in the same
room as, and ahead of the union connection for appliances in accordance with Section G2419.5.
IRC (675 lAC 14-4.2).
1029020 Openings and outlets equipped for a hose connection shall be protected against backflow in
accordance with Section P2902.3.3, IRC (675 lAC 14-4.2).
3M903A FACTORY BUILT FIREPLACES SHALL BE IN ACCORDANCE WITH SECTION 903, IMC (675 lAC
18-1.4).
Please be advised that if an administrative revil.~w of this action is clesired, a written petition for review mLlst be tiled at the above address with the
Fire Prevention and Building Safety CQr:wlission identifying the matter for which a review is sought no later than eighteen (18) days from the above -
staled dale, unless the eighteenth day falls on a Saturday, a Sunday. a legal holiday under Stale statute, or a day in which Ihe Department of Fire
and BUllding Services is closed during normal business hours. In the latter case, the filing deadline will be the first working day thereafter. If you
choose 10 petition, and the before'mentioned'procedures'are'foUowed, yOuf'petitiof',fonevie.....' wHl be granted,Gnd anadm(nistrative proceeding wUl
be conducted by an administrative law judge of the Fire Prever.tion and Buildin\; Salety Commission. If a petition for review is not fited, Ihis Order will
be finaL and you O1l1st comply with its requirements
r--._.~'-"_."- ..-._-."_.._~---~--~._~~-~~-~._-_..,.._._.
I F'iled By i Code roview offiGial
, I
i : PA TRICIA CRAYTON
r--..-.-----..--....--.-.....---......--I...-............. .-.-.......----......----.-.--....--....-..
, Address (name.title of local off!c-ial;st.~eet.clty,state and ZIP code
I DEPT OF COMMUNITY SERVICE
, JIM BLANCHARD
i ONE CIVIC SQUARE
I CARMEL. IN 40032
I
I.._~??' & e-ma!~~.?g.'~.?~~~j~@I]_~~_~.m[~~!:!!l_~.in.gg:-:__.
..
. .
. .
.-c:~~_---:....-tcode'Ef1fo.rc~meti(;n'.iar. Revlew Bfsnch,6irecio";.m-.'__-'""-.---'-'-.-'.'-j
I I
! /J "'/ -<f//-~/L_
.j V~P7...~i
,_ _________ ___.___..______.__ ----------1
j Slate Fire Marshal V1~ 0 ~ i
I
..~'"__.^..._.. _l _ . ___ ~______ ._____ _ -_ _ - --~-- ---- --- ~._..
Page 2/2