Loading...
HomeMy WebLinkAboutGENERIC_TEMPLATE_1340_ROHRER_RD_rev5.pdfFAJdraftingsolutions 5234 RINEHART AVE INDIANAPOLIS, INDIANA, 46241 (317) 737-0202 (317) 401-9071 Ow ner FOR CONSTRUCTION THESE DRAWINGS AND ALL COPIES ARE AND SHALL REMAIN THE PROPERTY AND COPYRIGHT OF THE ARCHITECT AND SHALL NOT BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS, MECHANICAL OR ELECTRONIC, WITHOUT EXPRESS WRITTEN PERMISSION OF THE ARCHITECT. THEY SHALL BE USED ONLY WITH RESPECT TO THIS PROJECT AND ARE NOT TO BE USED ON ANY OTHER PROJECT OR WORK WITHOUT PRIOR WRITTEN PERMISSION FROM THE ARCHITECT. COPYRIGHT 2023, BY FAJ DraftingSolutions L.L.C ROHRERREMODELING1340 ROHRER RD,CARMEL,INDIANAIssue Date/ProjectStatusPROJECT NUMBER 000-G COVER SHEET DRAWN BY CHECKED BY 07222023 F.R CHECKER 8/1/2023 9:01:06 AMG:/Other computers/My Computer (1)/PROJECT/OPEN PROJECTS/1340 ROHRER RD - G: -- GENERIC_TEMPLATE_627_HANNIBAL_ST134 0 ROHRER RD,CARMEL,INDIANA STATE MAP VICINITY PLAN LOCATION PLAN INDEX / PLAN INFORMATION INDEX OF DRAWINGS COVER SHEET 000-G GENERAL NOTES &SITE PLAN 001-G DEMOLITION PLANS 002-G PROPOSED 1ST & 2ND FLOOR A-100 PROPOSED FRAMING PLAN A-101 ELEVATIONS B-200 PROPOSED ELECTRICAL PLAN E-300 PROPOSED PLUMBING /HVAC PLAN F-400 HOUSE OVERVIEW DETAILS D-500 RENDERING D-501 RENDERING D-502 RENDERING D-503 RENDERING D-504 RENDERING D-505 ALTHOUGH EVERY EFFORT HAS BEEN MADE IN PREPARING THESE PLANS AND CHECKING THEM FOR ACCURACY, THE CONTRACTOR MUST CHECK ALL DETAILS AND DIMENSIONS AND BE RESPONSIBLE FOR THE SAME FOR ALL GOVERNING CODES AND BUILDING PRACTICES. THESE DRAWINGS CONFORM TOGENERALLY ACCEPTED BUILDING PRACTICES; HOWEVER, STATE AND LOCAL CODES VARY WIDELY. THE DRAFTSMAN, FRANCISCO J RUBI, SHALL NOT BE HELD LIABLE FOR ANY ERRORS. ALL CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE STATE AND LOCAL CODES. DO NOT SCALE DRAWINGS, USE ONLY THEPRINTED DIMENSIONS. VERIFY WITH THE WINDOW MANUFACTURER ALL WINDOWS SIZES AND APPLICABLE EGRESS REQUIREMENTS. ALL DIMENSIONS ARE TAKEN FROM/TO ROUGH STUDS OF A DIMENSION OF EITHER 5 ½” (2X6 STUDS), 3 ½” (2X4 STUDS), OR TO THE OUTSIDE OF MASONRY. THE CONTRACTOR SHALLVERIFY ALL MECHANICAL AND ELECTRICAL REQUIREMENTS AND CLEARANCE. CONTRACTOR SHALL VERIFY ALL FLOOR AND ROOF BEARING LOCATIONS. CONTRACTOR SHALL VERIFY ALL BEAM AND HEADER SIZES FOR CODE COMPLIANCE. CITY STAMP FOR CITY USED FAJdraftingsolutions 5234 RINEHART AVE INDIANAPOLIS, INDIANA, 46241 (317) 737-0202 (317) 401-9071 Ow ner FOR CONSTRUCTION THESE DRAWINGS AND ALL COPIES ARE AND SHALL REMAIN THE PROPERTY AND COPYRIGHT OF THE ARCHITECT AND SHALL NOT BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS, MECHANICAL OR ELECTRONIC, WITHOUT EXPRESS WRITTEN PERMISSION OF THE ARCHITECT. THEY SHALL BE USED ONLY WITH RESPECT TO THIS PROJECT AND ARE NOT TO BE USED ON ANY OTHER PROJECT OR WORK WITHOUT PRIOR WRITTEN PERMISSION FROM THE ARCHITECT. COPYRIGHT 2023, BY FAJ DraftingSolutions L.L.C ROHRERREMODELING1340 ROHRER RD,CARMEL,INDIANAIssue Date/ProjectStatusPROJECT NUMBER 001-G GENERAL NOTES & SITE PLAN DRAWN BY CHECKED BY 07222023 F.R CHECKER 8/1/2023 9:01:06 AMG:/Other computers/My Computer (1)/PROJECT/OPEN PROJECTS/1340 ROHRER RD - G: -- GENERIC_TEMPLATE_627_HANNIBAL_STGENERAL NOTES THE DRAWINGS INDICATE THE GENERAL SCOPE OF THE PROJECT IN TERMS OF ARCHITECTURAL DESIGN CONCEPT, DIMENSIONS OF THE BUILDING, MAJOR ARCHITECTURAL ELEMENTS AND THE TYPE OF STRUCTURAL SYSTEM. AS SCOPE REQUIRED FOR FULL PERFORMANCE AND COMPLETION OF THE REQUIREMENTS OF THE CONTRACT DOCUMENTS. ON THE BASIS OF THE GENERAL SCOPE INDICATED OR DESCRIBED, THE TRADE CONTRACTORS SHALL FURNISH ALL ITEMS REQUIRED FOR THE PROPER EXECUTION AND COMPLETION OF THE WORK. THESE CONTRACT DOCUMENTS DO NOT ATTEMPT TO INSTRUCT THE CONTRACTOR IN THE SPECIFIC DETAILS OF HIS TRADE. ALL WORK SHALL BE IN ACCORDANCE WITH THE QUALITY STANDARDS OF THE TRADE AND SHALL BE INSTALLED IN COMPLIANCE, AS A MINIMUM STANDARD, TO ALL APPLICABLE LOCAL, STATE AND FEDERAL CODES AND MANUFACTURER'S RECOMMENDATIONS. ALL WORK SHALL BE WARRANTED SATISFACTORY, IN MATERIALS AND WORKMANSHIP, FOR A MINIMUM PERIOD OF ONE (1) YEAR OR FOR THE CUSTOMARY PERIOD OF WARRANTY OR AS STIPULATED FOR THE TRADE, CRAFT OR PRODUCT WHICHEVER IS LONGER GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFICATION OF ALL DIMENSIONS AND JOB CONDITIONS PRIOR TO STARTING CONSTRUCTION UNLESS OTHERWISE INDICATED. NOTIFY THE ARCHITECT/ENGINEER OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH CONSTRUCTION. THE COORDINATION OF ALL MATERIALS, LABOR AND WORKMANSHIP IS THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR. COMMENCING WORK BY A CONTRACTOR OR SUBCONTRACTOR CONSTITUTES ACCEPTANCE OF THE CONDITIONS AND SURFACE CONCERNED. IF SUCH CONDITIONS OR SURFACES ARE UNACCEPTABLE, THE GENERAL CONTRACTOR SHALL BE NOTIFIED IMMEDIATELY AND WORK SHOULD CEASE UNTIL THE UNACCEPTABLE CONDITIONS CAN BE REMEDIED. THE CONTRACTOR IS RESPONSIBLE FOR CONTACTING LOCAL BUILDING OFFICIALS AND INSPECTORS FOR PERMITS AND INSPECTIONS. ADVISE THE ARCHITECT IMMEDIATELY OF AN DISCREPANCIES. THE GENERAL CONTRACTOR IS SHALL PROVIDE A THOROUGH CONSTRUCTION CLEAN-UP PRIOR TO OWNER/TENANT TAKING OCCUPANCY OF ANY SPACE. CLEAN-UP SHALL INCLUDE, BUT NOT BE LIMITED TO CLEANING ALL SURFACES AND VACUUM AND CLEANING ALL CARPETING AND WINDOW TREATMENTS. PROVIDE METAL OR FIRE RETARDANT TREATED WOOD BLOCKING IN NEW AND EXISTING WALLS FOR ALL WALL SUPPORTED ITEMS. AT ALL EXISTING WALLS, PATCH AND REPAIR WALL FINISH TO MATCH ADJACENT WALL SURFACE AS REQUIRED FOLLOWING THE INSTALLATION OF BLOCKING. TRANSPORT TRASH, RUBBISH AND DEBRIS FROM THE SITE AND LEGALLY DISPOSE OF SAME. THE MANNER OF REMOVAL MUST BE CONFIRMED WITH THE OWNER AND AS ALLOWED BY CITY AND STATE REGULATIONS. ALL DIMENSIONS ARE TAKEN FROM FACE OF STUD OR FACE OF BLOCK OR CONCRETE TO FACE OF STUD OR FACE OF BLOCK OR CONCRETE, COLUMN LINES, UNLESS OTHERWISE SPECIFIED. DO NOT SCALE DRAWINGS. REFER TO DIMENSIONS ILLUSTRATED ON DRAWINGS, NOTIFY THE ARCHITECT/ENGINEER OF DISCREPANCIES FOR CLARIFICATION. ALL STUD WALLS SHALL BE SECURED TO THE CONCRETE FLOOR AND CEILING OR FLOOR/ROOF CONSTRUCTION ABOVE. PROVIDE EXPANSION/CONTROL JOINTS IN THE GYPSUM WALL BOARD WALLS OVER 30'-0" IN LENGTH PER THE MANUFACTURER'S RECOMMENDATIONS. COORDINATE LOCATIONS OF EXPANSION/CONTROL JOINTS WITH THE ARCHITECT PRIOR TO INSTALLATION FOR COMPLIANCE WITH DESIGN INTENT. ALL STUD OR MASONRY WALLS EXTENDING FROM FLOOR TO ROOF/FLOOR STRUCTURE ABOVE MUST PROVIDE FOR A MINIMUM OF 2" VERTICAL ROOF/FLOOR DEFLECTION. ALL JOINTS AND PENETRATIONS OF FIRE RATED ASSEMBLIES TO BE SEALED WITH APPROVED U.L. LISTED "F" AND "T" SYSTEMS. SUBMIT PRODUCT DATA AND INSTALLATION INFORMATION PRIOR TO INSTALLATION FOR ARCHITECTS APPROVAL. FURNISH AND INSTALL PLUMBING FIXTURES AS SHOWN. ALL EXPOSED PIPING AND SUPPLY FITTINGS SHALL BE CHROME PLATED UNLESS OTHERWISE INDICATED. ALL WALL PENETRATIONS SHALL BE FITTED WITH CHROMIUM PLATED ESCUTCHEONS. FIXTURES INDICATE AS HANDICAP ACCESSIBLE SHALL COMPLY WITH A.D.A. REQUIREMENTS. HOT WATER AND DRAIN PIPES UNDER LAVATORIES AND HANDICAP ACCESSIBLE SINKS SHALL BE INSTALLED OR OTHERWISE CONFIGURED TO PROTECT AGAINST CONTACT. WHERE DISSIMILAR FLOOR MATERIALS MEET, THEY SHALL DO SO UNDER THE CENTERLINE OF A DOOR UNLESS OTHERWISE INDICATED. HINGE SIDE OF FINISH DOOR JAMB IN METAL STUD WALLS SHALL TYPICALLY BE LOCATED 6" FROM ADJACENT FINISHED WALL UNLESS OTHERWISE INDICATED. MATERIALS EXPOSED WITHIN PLENUM SPACES DESIGNED TO ALLOW AIR MOVEMENT AND FUNCTION AS PART OF THE AIR DISTRIBUTION SYSTEM ARE REQUIRED TO BE NONCOMBUSTIBLE OR SHALL HAVE A FLAME SPREAD INDEX LESS THAN 25 AND A SMOKE DEVELOPED INDEX LESS THAN 50 WHEN TESTED IN ACCORDANCE WITH ASTM E 84. APPLICATION OF FINISH COAT TO SURFACE INDICATES THAT CONTRACTOR HAS ACCEPTED SUBSTRATE AS BEING SATISFACTORY. ALL WALLS AROUND TOILET ROOMS ARE TO HAVE BATT INSULATION INSTALLED FULL DEPTH AND HEIGHT. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE ACCURACY OF THE BUILDING LINES AND LEVELS AND KEEPING THE STRUCTURE IN SQUARE. THE GENERAL CONTRACTOR SHALL COMPARE CAREFULLY THE LINES AND LEVELS SHOWN ON THE DRAWINGS WITH EXISTING LEVELS FOR THE CONSTRUCTION OF THE WORK. THEY SHALL CALL THE ARCHITECT'S ATTENTION TO ANY DISCREPANCIES BEFORE PROCEEDING WITH ANY REQUIRED CORRECTION TO THE WORK. ALL LUMBER IN CONTACT WITH CONCRETE MASONRY OR SOIL SHALL BE WATER RESISTANT PRESSURE TREATED. PROVIDE RODENT AND INSECT PROOFING WHERE ALL PLUMBING, WIRING, AND VENTS PASS THROUGH PLATES, AS PER CODE REQUIREMENTS. CONTACT RESPECTIVE UTILITY COMPANIES FOR EXACT LOCATIONS OF UNDERGROUND SERVICES PRIOR TO START OF CONSTRUCTION. TAKE EVERY PRECAUTION NECESSARY TO PROTECT EXISTING SERVICES DURING CONSTRUCTION. REVIEW ALL DRAWINGS (ARCHITECTURAL, MECHANICAL, ELECTRICAL, STRUCTURAL), FOR ALL INFORMATION CONCERNING SLEEVES, BOXES, ANCHORS, VENTS, OPENINGS, ETC., THAT MAY BE REQUIRED. EACH RESPECTIVE TRADE IS RESPONSIBLE FOR PROVIDING AND INSTALLING THESE ITEMS. CODE SUMMARY EMERGENCY ESCAPE AND RESCUE OPENINGS EVERY SLEEPING ROOM SHALL HAVE AT LEAST ONE OPENABLE EMERGENCY ESCAPE AND RESCUE OPENING SMOKE ALARMS REQUIRED SMOKE ALARM LOCATIONS: LIVING AREA ALL BEDROOMS OR SLEEPING AREAS ON THE CEILING OF THE UPPER LEVEL NEAR THE TOP OR ABOVE EACH STAIRWAY BUILDING GROSS S.F BASEMENT _X FIRST FLOOR HALF BATH 20 SQ FT ENTRY 52 SQ FT DINING ROOM 400 SQ FT KITCHEN 171 SQ FT LIVING ROOM 159 SQ FT FIRST FLOOR ROUGH TOTAL: 802 SQ FT SECOND FLOOR MASTER BEDROOM 195 SQ FT BEDROOM 1 122 SQ FT BEDROOM 2 104 SQ FT MASTER BATH 46 SQ FT BATHROOM 61 SQ FT HALL 76 SQ FT ATTIC _X GARAGE GARAGE 800 SQ FT ROUGH TOTAL : 2,206 SQ FT ABBREVIATIONS ACP ACOUSTIC CEILING PANEL ACG ACOUSTIC CEILING GRID ADJ ADJACENT A.F.F. ABOVE FINISHED FLOOR ALUM ALUMINUM APC ACOUSTICAL PANEL CEILING ASSBY ASSEMBLY CLG CEILING C.J. CONTROL JOINT CLR CLEAR CMU CONCRETE MASONRY UNIT CONC CONCRETE CONST CONSTRUCTION DIA DIAMETER DIV DIVISION DWGS DRAWINGS E.J. EXPANSION JOINT ELEV ELEVATION EQ EQUAL ETC ETCETERA EX/EXIST'G EXISTING FD FLOOR DRAIN FIN FINISH GWB GYPSUM WALL BOARD HM HOLLOW METAL HR HOUR JT. JOINT LAM LAMINATE MAT'L MATERIAL MAX MAXIMUM MFR MANUFACTURER M.O. MASONRY OPENING MIN MINIMUM MTL METAL N.I.C. NOT IN CONTRACT OFCI OWNER FURNISHED CONTRACTOR INSTALL OFOI OWNER FURNISHED OWNER INSTALL O.C. ON CENTER O.H. OVERHEAD OPP. OPPOSITE HAND P-LAM PLASTIC LAMINATE REF. REFERENCE, REFER TO REQ'D REQUIRED R.O. ROUGH OPENING S.F. SQUARE FOOT SHT LAM LAMINATE MAT'L MATERIAL MAX MAXIMUM MFR MANUFACTURER M.O. MASONRY OPENING MIN MINIMUM MTL METAL N.I.C. NOT IN CONTRACT OFCI OWNER FURNISHED CONTRACTOR INSTALL OFOI OWNER FURNISHED OWNER INSTALL O.C. ON CENTER O.H. OVERHEAD OPP. OPPOSITE HAND P-LAM PLASTIC LAMINATE REF. REFERENCE, REFER TO REQ'D REQUIRED R.O. ROUGH OPENING S.F. SQUARE FOOT INDEX OF DRAWINGS COVER SHEET 000-G GENERAL NOTES &SITE PLAN 001-G DEMOLITION PLANS 002-G PROPOSED 1ST & 2ND FLOOR A-100 PROPOSED FRAMING PLAN A-101 ELEVATIONS B-200 PROPOSED ELECTRICAL PLAN E-300 PROPOSED PLUMBING /HVAC PLAN F-400 HOUSE OVERVIEW DETAILS D-500 RENDERING D-501 RENDERING D-502 RENDERING D-503 RENDERING D-504 RENDERING D-505 OWNER: Joe Real Estate Inc PROJECT:RohrerRemodeling ADDRESS:1340 ROHRER RD LOCAL PARCEL #: 17-09-24-00-04-001.000 STATE PARCEL #: 29-09-24-004-001.000-018 ESTIMATED SQUARE FEET: SECTION/TOWNSHIP/RANGE: TOWNSHIP 18 SUBDIVISION NAME: CLASSIFICATION:RESIDENTIAL LEGAL DESCRIPTION : FIRE DISTRICT CARMEL FIRE DEPARTMENT WATER/SEWER:CITY OF CARMEL UTILITIES STORM WATER PERMIT: _____________________ BUILDING PERMIT: _____________________ DESIGNER: _____________________ DESIGN CONSULTANT:_____________________ BUILDER:_____________________ SITE DISTURBANCE:_____________________ ENGINEERING: _____________________ PROJECT NARRATIVE THE PROPOSED SITE LOCATION IS 1340 ROHRER RD. PARCEL #11-10-01-02-04-003.00017-09-24-00-04-001.000 OPEN CASES: _x THE PROPOSED PROJECT INCLUDES: - COMPLETE REMODELING OF 1ST FLOOR - COMPLETE REMODELING OF 2ND FLOOR - REMOVE SPECIFIC WALLS TO OPEN SPACE AND BUILD NEW FRAMING ( PLEASE REFER TO FLOOR PLANS FOR MORE DETAILS) - REMOVE WINDOWS AND REPLACE WITH NEW ONES. ( PLEASE REFER TO FLOOR PLANS FOR MORE DETAILS) - REMOVE EXISTING SIDING AND INSTALL NEW ONE. - REMOVE EXISTING ROOF SHINGLES AND INSTALL NEW ONES AS PER OWNER PREFERENCE. - REPAIR EXISTING FLOOR AS NEEDED AND INSTALL NEW FLOOR FINISH AS PER OWNER PREFERENCE ( LAMINATED FLOORING, CARPET, TILE ,ETC) - BUILD NEW BATHROOM IN 2ND FLOOR. - CREATE NEW MASTER BATHROOM. - NEW ELECTRICAL WIRING - NEW PLUMBING SYSTEM - NEW HVAC SYSTEM ALTHOUGH EVERY EFFORT HAS BEEN MADE IN PREPARING THESE PLANS AND CHECKING THEM FOR ACCURACY, THE CONTRACTOR MUST CHECK ALL DETAILS AND DIMENSIONS AND BE RESPONSIBLE FOR THE SAME FOR ALL GOVERNING CODES AND BUILDING PRACTICES. THESE DRAWINGS CONFORM TOGENERALLY ACCEPTED BUILDING PRACTICES; HOWEVER, STATE AND LOCAL CODES VARY WIDELY. THE DRAFTSMAN, FRANCISCO J RUBI, SHALL NOT BE HELD LIABLE FOR ANY ERRORS. ALL CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE STATE AND LOCAL CODES. DO NOT SCALE DRAWINGS, USE ONLY THEPRINTED DIMENSIONS. VERIFY WITH THE WINDOW MANUFACTURER ALL WINDOWS SIZES AND APPLICABLE EGRESS REQUIREMENTS. ALL DIMENSIONS ARE TAKEN FROM/TO ROUGH STUDS OF A DIMENSION OF EITHER 5 ½” (2X6 STUDS), 3 ½” (2X4 STUDS), OR TO THE OUTSIDE OF MASONRY. THE CONTRACTOR SHALLVERIFY ALL MECHANICAL AND ELECTRICAL REQUIREMENTS AND CLEARANCE. CONTRACTOR SHALL VERIFY ALL FLOOR AND ROOF BEARING LOCATIONS. CONTRACTOR SHALL VERIFY ALL BEAM AND HEADER SIZES FOR CODE COMPLIANCE. CITY STAMP FOR CITY USED SITEPLAN SCALE: 1/4" = 1' 22 22 EXISTING 2X4 WALL TO BE REMOVED TO CREATE SPACE FOR NEW FRAMING. CONTRACTOR TO PROVIDE TEMPORARY SUPPORT FOR ANY LOAD-BEARING ELEMENTS AFFECTED BY THE REMOVAL OF THE WALL. THE NEW FRAMING SHALL BE CONSTRUCTED IN ACCORDANCE WITH LOCAL BUILDING CODES EXISTING 2X4 WALL TO BE REMOVED TO CREATE SPACE FOR NEW FRAMING. CONTRACTOR TO PROVIDE TEMPORARY SUPPORT FOR ANY LOAD-BEARING ELEMENTS AFFECTED BY THE REMOVAL OF THE WALL. THE NEW FRAMING SHALL BE CONSTRUCTED IN ACCORDANCE WITH LOCAL BUILDING CODES 11 11 11 FAJdraftingsolutions 5234 RINEHART AVE INDIANAPOLIS, INDIANA, 46241 (317) 737-0202 (317) 401-9071 Ow ner FOR CONSTRUCTION THESE DRAWINGS AND ALL COPIES ARE AND SHALL REMAIN THE PROPERTY AND COPYRIGHT OF THE ARCHITECT AND SHALL NOT BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS, MECHANICAL OR ELECTRONIC, WITHOUT EXPRESS WRITTEN PERMISSION OF THE ARCHITECT. THEY SHALL BE USED ONLY WITH RESPECT TO THIS PROJECT AND ARE NOT TO BE USED ON ANY OTHER PROJECT OR WORK WITHOUT PRIOR WRITTEN PERMISSION FROM THE ARCHITECT. COPYRIGHT 2023, BY FAJ DraftingSolutions L.L.C ROHRERREMODELING1340 ROHRER RD,CARMEL,INDIANAIssue Date/ProjectStatusPROJECT NUMBER 002-G DEMOLITION PLANS DRAWN BY CHECKED BY 07222023 F.R CHECKER 8/1/2023 9:01:06 AMG:/Other computers/My Computer (1)/PROJECT/OPEN PROJECTS/1340 ROHRER RD - G: -- GENERIC_TEMPLATE_627_HANNIBAL_STALTHOUGH EVERY EFFORT HAS BEEN MADE IN PREPARING THESE PLANS AND CHECKING THEM FOR ACCURACY, THE CONTRACTOR MUST CHECK ALL DETAILS AND DIMENSIONS AND BE RESPONSIBLE FOR THE SAME FOR ALL GOVERNING CODES AND BUILDING PRACTICES. THESE DRAWINGS CONFORM TOGENERALLY ACCEPTED BUILDING PRACTICES; HOWEVER, STATE AND LOCAL CODES VARY WIDELY. THE DRAFTSMAN, FRANCISCO J RUBI, SHALL NOT BE HELD LIABLE FOR ANY ERRORS. ALL CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE STATE AND LOCAL CODES. DO NOT SCALE DRAWINGS, USE ONLY THEPRINTED DIMENSIONS. VERIFY WITH THE WINDOW MANUFACTURER ALL WINDOWS SIZES AND APPLICABLE EGRESS REQUIREMENTS. ALL DIMENSIONS ARE TAKEN FROM/TO ROUGH STUDS OF A DIMENSION OF EITHER 5 ½” (2X6 STUDS), 3 ½” (2X4 STUDS), OR TO THE OUTSIDE OF MASONRY. THE CONTRACTOR SHALLVERIFY ALL MECHANICAL AND ELECTRICAL REQUIREMENTS AND CLEARANCE. CONTRACTOR SHALL VERIFY ALL FLOOR AND ROOF BEARING LOCATIONS. CONTRACTOR SHALL VERIFY ALL BEAM AND HEADER SIZES FOR CODE COMPLIANCE. CITY STAMP FOR CITY USED DEMOLITION 1ST FLOOR PLAN SCALE: 1/4" = 1' DEMOLITION NOTESDEMOLITION NOTES 1.COORDINATE THE EXTENT OF DEMOLITION WORK WITH ALL NEW CONSTRUCTION, AS INDICATED IN CONTRACT DOCUMENTS. 2.THESE DEMOLITION NOTES REPRESENT SURVEYED SPACES BEFORE DEMOLITION WORK. LOCATION OF CASEWORK, COUNTERS, ETC. WITHIN THESE DOCUMENTS MAY NOT BE COMPLETELY ACCURATE. FIELD VERIFY THE EXACT SIZES AND LOCATION OF ALL EXISTING WORK PRIOR TO CONSTRUCTION. CONTACT THE ARCHITECT IN THE EVENT OF CONFLICTS. 3.ALL DEMOLITION ITEMS SHALL BE CONSIDERED PROPERT Y OF THE OWNER UNTIL VERIFICATION HAS BEEN MADE AS TO ITEMS TO BE RETAINED, PRIOR TO REMOVAL FROM THE SITE. ALL ITEMS NOT TO BE RETAINED SHALL BE REMOVED FROM THE SITE BY THE CONTRACTOR. 4.CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO ENSURE THAT THE BUILDING REMAINS WATERTIGHT AND SECURE AT ALL TIMES. 5.CONTRACTOR SHALL PROVIDE ALL TEMPORARY PARTITIONS AND DOORS AS DEEMED NECESSARY BY ARCHITECT AND OWNER TO AVOID MIGRATION OF DUST INTO ADJOINING AND OCCUPIED AREAS. 6.PROTECT ALL EXISTING STRUCTURAL SUPPORTS. 7.MAKE ALL DEMOLITION CLEAN AND COMPLETE AND IN A MANNER SUITABLE TO ACCEPT NEW FINISHES AND/OR SURFACES. 8.WHEN DEMOLITION CAUSES OR EXPOSES DAMAGE TO EXISTING SLAB, FLOOR, WALL, OR CEILING SURFACES WHICH WILL REMAIN EXPOSED IN THE FINISHED WORK, THE CONTRACTOR SHALL REPAIR AND LEVEL SUCH CONDITIONS AS REQUIRED. 9.REMOVE EXISTING FLOOR, WALL, AND CEILING FINISHES WITHIN BOUNDARY OF PROJECT SUITE. PROTECT ALL EXISTING CORRIDOR INTERIOR FINISHES TO REMAIN. 10.WHERE ANY EXISTING PIPING OR DUCTWORK IN FLOORS, WALLS, OR CEILINGS IS TO BE REMOVED OR RELOCATED, FILL IN PENETRATION OPENINGS FLUSH WITH AND OF THE SAME MATERIALS. 11.REFERENCE STRUCTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL DEMOLITION DRAWINGS FOR ADDITIONAL INFORMATION, IN ACCORDANCE WITH INDIANA BUILDING CODE REGULATIONS AND STANDARDS. 12.REMOVAL OF ANY ASBESTOS IS THE RESPONSIBILIT Y OF THE OWNER, IN ACCORDANCE WITH INDIANA BUILDING CODE SECTION 3310. NOTIFY THE ARCHITECT IF SUCH MATERIAL IS DISCOVERED DURING DEMOLITION OPERATIONS. 13.DASHED LINES INDICATE TO REMOVE WALLS, DOORS, FRAMES, AND ASSOCIATED ITEMS COMPLETE, IN ACCORDANCE WITH INDIANA BUILDING CODE SECTION 3306. 1 SAFET Y FIRST: BEFORE BEGINNING ANY WORK ON ASBESTOS REMOVAL, ENSURE THAT ALL NECESSARY SAFET Y PRECAUTIONS ARE TAKEN. THIS INCLUDES WEARING APPROPRIATE PERSONAL PROTECTIVE EQUIPMENT (PPE), SUCH AS GLOVES, EYE PROTECTION, RESPIRATORY MASKS, AND FULL BODY SUITS. 2 ASBESTOS IDENTIFICATION: IDENTIFY ALL POTENTIAL SOURCES OF ASBESTOS-CONTAINING MATERIALS (ACMS) BEFORE ANY REMOVAL WORK BEGINS. ONLY TRAINED PROFESSIONALS SHOULD PERFORM THE IDENTIFICATION PROCESS. 3 COMPLIANCE: ENSURE THAT ALL ASBESTOS REMOVAL ACTIVITIES ARE IN COMPLIANCE WITH LOCAL, STATE, AND FEDERAL REGULATIONS, INCLUDING PROPER LICENSING AND CERTIFICATIONS. 4 CONTAINMENT: ESTABLISH CONTAINMENT AREAS TO PREVENT THE RELEASE OF ASBESTOS FIBERS INTO THE SURROUNDING ENVIRONMENT. THIS INCLUDES THE USE OF AIRLOCKS AND NEGATIVE AIR PRESSURE SYSTEMS. 5 REMOVAL TECHNIQUE: USE THE APPROPRIATE TECHNIQUES FOR REMOVING ASBESTOS-CONTAINING MATERIALS, SUCH AS WET REMOVAL OR ENCAPSULATION. 6 WASTE DISPOSAL: ASBESTOS WASTE MUST BE PROPERLY PACKAGED AND LABELED, AND DISPOSED OF AT A LICENSED LANDFILL. IT IS IMPORTANT TO FOLLOW ALL REGULATIONS AND GUIDELINES FOR ASBESTOS WASTE DISPOSAL. 7 SITE RESTORATION: AFTER THE ASBESTOS-CONTAINING MATERIALS HAVE BEEN REMOVED, TAKE NECESSARY STEPS TO RESTORE THE SITE TO ITS ORIGINAL CONDITION. THIS INCLUDES CLEANING THE AREA, AND ENSURING THAT ALL SURFACES ARE FREE OF ASBESTOS FIBERS. 8 QUALIT Y CONTROL: ENSURE THAT THE FINISHED SURFACE MEETS THE REQUIRED SPECIFICATIONS, INCLUDING SMOOTHNESS AND LEVELNESS. 9 COST ESTIMATION: CALCULATE THE COST OF THE ASBESTOS REMOVAL PROCESS, INCLUDING EQUIPMENT, LABOR, DISPOSAL EXPENSES, AND ANY NECESSARY TESTING, TO ENSURE THAT THE PROJECT STAYS WITHIN BUDGET. 10 PROJECT TIMELINE: DEVELOP A REALISTIC TIMELINE FOR THE ASBESTOS REMOVAL PROCESS, TAKING INTO ACCOUNT FACTORS SUCH AS WEATHER CONDITIONS AND ANY NECESSARY PERMITS OR APPROVALS. IT IS IMPORTANT TO ADHERE TO THE TIMELINE TO MINIMIZE THE RISK OF ASBESTOS EXPOSURE. SAFET Y NOTESSAFETY NOTES DEMOLITION 2ND FLOOR PLAN SCALE: 1/4" = 1' EXISTING GARAGEEXISTING GARAGE 11 11 11 22 22 66 77 88 99 1010 10101111 44 EXISTING FIREPLACE LIVING ROOM 12'-3" X 11'-8" ENTRY 5'-2" X 8'-0" KITCHEN 12'-8" X 12'-0" DINING 12'-5" X 27'-1" LAUNDRY 12'-2" X 5'-1" MECHANICAL 5'-10" X 13'-5" G05G05 G02G02 G04G04 G01G01 G06G06 G10G10 HALFT BATH 6'-6" X 2'-8" G07G07 11 11 11 11 11 33 22 22 44 4411 55 55HALL 10'-3" X 6'-3" BEDROOM 2 8'-2" X 11'-4" CLOSET 3 6'-2" X 2'-9" BEDROOM 1 11'-5" X 9'-9" CLOSET 2 11'-5" X 2'-0" CLOSET 1 13'-4" X 2'-0" MASTER BEDROOM 13'-4" X 13'-7" MASTER BATH 13'-4" X 4'-0" BATHROOM 5'-11" X 6'-3" STAIRWELL 8'-11" X 2'-11" G13G13 G18G18 G11G11 G19G19 G12G12 G20G20 NOTE SCHEDULE NEW INSTALLED DOOR AND FRAME. REFERENCE DOOR & WINDOW SCHEDULE SHEET FOR DETAILS. REPLACE EXISTING WINDOW WITH NEW WINDOW. REFERENCE DOOR & WINDOW SCHEDULE SHEET FOR DETAILS. NEW INSTALLED WINDOW AND FRAME. REFERENCE DOOR & WINDOW SCHEDULE SHEET FOR DETAILS. OWNER FURNISHED, CONTRACTOR INSTALLED VANITY/SINK LOCATION. PROVIDE ALL NECESSARY WATER LINE & PLUMBING CONNECTION OWNER FURNISHED, CONTRACTOR INSTALLED STAND-UP SHOWER/BATH TUB LOCATION, PROVIDE ALL NECESSARY WATER LINE & PLUMBING CONNECTION OWNER FURNISHED, CONTRACTOR INSTALLED ELECTRIC STOVE AND OVEN, PROVIDE ALL NECESSARY CONNECTIONS & 220V POWER OUTLET. OWNER FURNISHED, CONTRACTOR INSTALLED KITCHEN SINK LOCATION, PROVIDE ALL NECESSARY CONNECTIONS. OWNER FURNISHED, CONTRACTOR INSTALLED REFRIGERATOR CONNECTION, PROVIDE ALL NECESSARY CONNECTIONS OWNER FURNISHED, CONTRACTOR INSTALLED WASHER & DRYER LOCATION, PROVIDE ALL NECESSARY CONNECTIONS ALONG WITH 220A POWER OUTLET OWNER FURNISHED, CONTRACTOR INSTALLED CABINETS / COUNTER TOP LOCATION. OWNER FURNISHED, CONTRACTOR INSTALLED ISLAND CABINETS / COUNTER TOP LOCATION. WASTE LINE 11 22 33 44 55 66 77 88 99 1010 1111 WW 11 22 33 44 55 66 77 88 99 1010 1111 WW ROOM SCHEDULE NUMBER ROOM NAME AREA, STANDARD SQF ROOM TYPE G01 DINING 400 DINING G02 ENTRY 51 ENTRY G04 KITCHEN 162 KITCHEN G05 LIVING ROOM 159 LIVING G06 LAUNDRY 9 LAUNDRY G07 HALFT BATH 22 BATH G08 LAUNDRY 69 LAUNDRY G10 MECHANICAL 86 MECHANICAL G11 BATHROOM 46 BATH G12 BEDROOM 1 122 BEDROOM G13 BEDROOM 2 104 BEDROOM G18 HALL 76 HALL G19 MASTER BATH 61 BATH G20 MASTER BEDROOM 195 BEDROOM G21 STAIRWELL 30 OPEN BELOW TOTALS: 1591 WALL LEDGEND 2D SYMBOL WALL TYPE DESCRIPTION EXT1 EXTERIOR WALL, 2 X 4 WOOD STUDS (PLACED 16" APART, TYPICAL) WITH SOUND BATT INSULATION IN CORE, 5 8" PLYWOOD SHEETING BOARD, AND 12" CEMENT PANEL ON EXTERIO INT1 INTERIOR WALL, 2 X 4 WOOD STUDS (PLACED 16" APART, TYPICAL) WITH 5 8" GYPSUM WALL BOARD ON EXTERIOR SIDE INTERIOR RAILING INTERIOR RAILING ROOM DIVIDER ROOM DIVIDER FAJdraftingsolutions 5234 RINEHART AVE INDIANAPOLIS, INDIANA, 46241 (317) 737-0202 (317) 401-9071 Ow ner FOR CONSTRUCTION THESE DRAWINGS AND ALL COPIES ARE AND SHALL REMAIN THE PROPERTY AND COPYRIGHT OF THE ARCHITECT AND SHALL NOT BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS, MECHANICAL OR ELECTRONIC, WITHOUT EXPRESS WRITTEN PERMISSION OF THE ARCHITECT. THEY SHALL BE USED ONLY WITH RESPECT TO THIS PROJECT AND ARE NOT TO BE USED ON ANY OTHER PROJECT OR WORK WITHOUT PRIOR WRITTEN PERMISSION FROM THE ARCHITECT. COPYRIGHT 2023, BY FAJ DraftingSolutions L.L.C ROHRERREMODELING1340 ROHRER RD,CARMEL,INDIANAIssue Date/ProjectStatusPROJECT NUMBER A-100 PROPOSED 1ST & 2ND FLOOR DRAWN BY CHECKED BY 07222023 F.R CHECKER 8/1/2023 9:01:06 AMG:/Other computers/My Computer (1)/PROJECT/OPEN PROJECTS/1340 ROHRER RD - G: -- GENERIC_TEMPLATE_627_HANNIBAL_STALTHOUGH EVERY EFFORT HAS BEEN MADE IN PREPARING THESE PLANS AND CHECKING THEM FOR ACCURACY, THE CONTRACTOR MUST CHECK ALL DETAILS AND DIMENSIONS AND BE RESPONSIBLE FOR THE SAME FOR ALL GOVERNING CODES AND BUILDING PRACTICES. THESE DRAWINGS CONFORM TOGENERALLY ACCEPTED BUILDING PRACTICES; HOWEVER, STATE AND LOCAL CODES VARY WIDELY. THE DRAFTSMAN, FRANCISCO J RUBI, SHALL NOT BE HELD LIABLE FOR ANY ERRORS. ALL CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE STATE AND LOCAL CODES. DO NOT SCALE DRAWINGS, USE ONLY THEPRINTED DIMENSIONS. VERIFY WITH THE WINDOW MANUFACTURER ALL WINDOWS SIZES AND APPLICABLE EGRESS REQUIREMENTS. ALL DIMENSIONS ARE TAKEN FROM/TO ROUGH STUDS OF A DIMENSION OF EITHER 5 ½” (2X6 STUDS), 3 ½” (2X4 STUDS), OR TO THE OUTSIDE OF MASONRY. THE CONTRACTOR SHALLVERIFY ALL MECHANICAL AND ELECTRICAL REQUIREMENTS AND CLEARANCE. CONTRACTOR SHALL VERIFY ALL FLOOR AND ROOF BEARING LOCATIONS. CONTRACTOR SHALL VERIFY ALL BEAM AND HEADER SIZES FOR CODE COMPLIANCE. CITY STAMP FOR CITY USED 1- ALL CONSTRUCTION WORK MUST COMPLY WITH THE INDIANA RESIDENTIAL CODE AS WELL AS ANY APPLICABLE LOCAL BUILDING CODES AND ZONING REGULATIONS. 2- THE MAXIMUM HEIGHT OF A RESIDENTIAL BUILDING SHALL BE DETERMINED BY THE LOCAL ZONING CODE. 2 ALL FOUNDATIONS AND FOOTINGS MUST BE DESIGNED IN ACCORDANCE WITH THE INDIANA RESIDENTIAL CODE. 3- ALL STRUCTURAL COMPONENTS SUCH AS WALLS, BEAMS, AND ROOF TRUSSES MUST BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH THE INDIANA RESIDENTIAL CODE. 4- THE MINIMUM CLEAR HEIGHT OF HABITABLE ROOMS, HALLS, AND CORRIDORS SHALL BE 7 FEET (2134 MM). 5- EVERY DWELLING UNIT MUST HAVE AT LEAST ONE ROOM THAT MEASURES AT LEAST 120 SQUARE FEET (11.15 SQ. METERS) AND HAS A MINIMUM DIMENSION OF 10 FEET (3048 MM). 6- EVERY DWELLING UNIT MUST HAVE AT LEAST ONE HABITABLE ROOM THAT HAS A WINDOW OR SKYLIGHT FACING DIRECTLY TO THE OUTDOORS, EXCEPT WHERE A ROOM IS LOCATED IN A BASEMENT OR WHERE THE ROOM IS A BATHROOM, TOILET ROOM, OR KITCHEN. 7- ALL HABITABLE ROOMS MUST HAVE A MINIMUM OF ONE OPENABLE WINDOW OR EXTERIOR DOOR FOR NATURAL VENTILATION. 8- ALL PLUMBING FIXTURES MUST BE INSTALLED IN ACCORDANCE WITH THE INDIANA PLUMBING CODE. 9- ALL ELECTRICAL WORK MUST BE INSTALLED IN ACCORDANCE WITH THE INDIANA ELECTRICAL CODE. 10- SMOKE DETECTORS MUST BE INSTALLED IN ACCORDANCE WITH THE INDIANA RESIDENTIAL CODE. 11- CARBON MONOXIDE DETECTORS MUST BE INSTALLED IN ACCORDANCE WITH THE INDIANA RESIDENTIAL CODE. 12- ALL EXTERIOR DOORS MUST BE WEATHERSTRIPPED. 13- ALL GLAZING IN HAZARDOUS LOCATIONS, SUCH AS IN DOORS AND SHOWER ENCLOSURES, MUST MEET SAFET Y GLAZING REQUIREMENTS AS SPECIFIED IN THE INDIANA RESIDENTIAL CODE. 14- ALL STAIRS MUST MEET THE MINIMUM REQUIREMENTS SPECIFIED IN THE INDIANA RESIDENTIAL CODE, INCLUDING MINIMUM TREAD AND RISER DIMENSIONS AND HANDRAIL REQUIREMENTS. 15- ALL DECKS AND BALCONIES MUST BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH THE INDIANA RESIDENTIAL CODE. 16- ALL EXTERIOR WALLS MUST BE CONSTRUCTED TO RESIST WIND AND WATER PENETRATION. 17- ALL INSULATION MUST MEET THE MINIMUM R-VALUE REQUIREMENTS SPECIFIED IN THE INDIANA RESIDENTIAL CODE. 18- ALL ROOFING MATERIALS AND INSTALLATION METHODS MUST COMPLY WITH THE INDIANA RESIDENTIAL CODE GENERAL NOT ESGENERAL N OTES PROPOSED 1ST FLOOR PLAN SCALE: 1/4" = 1' PROPOSED 2nd FLOOR PLAN SCALE: 1/4" = 1' TYPICAL WINDOW HEADER DETAIL (print at 1"=1') WOOD FRAMING ASSEMBLY WITH WEATHER STRIPPING 2X4 PLATE TO HEADER CONNECTION IN ACCORDANCE WITH SECTION R602.7.1 1 1/2" X 3 1/2" PRE - ENGINEERED LVL BEAM WATER / VAPOR BARRIER TYPICAL EXTERIOR DOOR HEADER DETAIL (print at 1"=1') WOOD FRAMING ASSEMBLY WITH WEATHER STRIPPING 2X4 PLATE TO HEADER CONNECTION IN ACCORDANCE WITH SECTION R602.7.1 1 1/2" X 3 1/2" PRE - ENGINEERED LVL BEAM WATER / VAPOR BARRIER TYPICAL EXTERIOR DOOR JAMB DETAIL (print at 1"=1') 2X4 FULL HEIGHT STUDS ON EACH END IN ACCORDANCE WITH COED TABLE R602.7.5. FULL HEIGHT STUDS TO BE NAILED TO BEAM WITH FOUR 16d NAILS (3.5" X 0.135") WATER / VAPOR BARRIER 2X4 WOOD JACK STUD GOING ALL THE WAY TO THE HEADER 1/2 PLYWOOD SHEETING BOARD TYPICAL EXTERIOR WINDOW JAMB DETAIL (print at 1"=1') 2X4 FULL HEIGHT STUDS ON EACH END IN ACCORDANCE WITH COED TABLE R602.7.5. FULL HEIGHT STUDS TO BE NAILED TO BEAM WITH FOUR 16d NAILS (3.5" X 0.135") WATER / VAPOR BARRIER 2X4 WOOD JACK STUD GOING ALL THE WAY TO THE HEADER 1/2 PLYWOOD SHEETING BOARD TYPICAL INTERIOR DOOR HEADER DETAIL (print at 1"=1') WOOD FRAMING ASSEMBLY WITH WEATHER STRIPPING 2X4 PLATE TO HEADER CONNECTION IN ACCORDANCE WITH SECTION R602.7.1 1 1/2" X 3 1/2" PRE - ENGINEERED LVL BEAM TYPICAL INTERIOR DOOR JAMB DETAIL (print at 1"=1') 2X4 FULL HEIGHT STUDS ON EACH END IN ACCORDANCE WITH COED TABLE R602.7.5. FULL HEIGHT STUDS TO BE NAILED TO BEAM WITH FOUR 16d NAILS (3.5" X 0.135") 1/2 GYPSUM WALL BOARD ON BOTH SIDES 2X4 WOOD JACK STUD GOING ALL THE WAY TO THE HEADER TYPICAL EXTERIOR DOOR SILL DETAILS (print at 1"=1') EXTERIOR CONCRETE PATIO FLOOR SEALANT JOINT EXTRUDED ALUMINUM THRESHOLD WOOD DOOR ADJUSTABLE METAL SILL STEPFINISH FLOOTING PT WOOD OR COMPOSITE SUB-SILL GRADE 5'-1"2'-6"5'-9"4'-1"CL 7'-3" CLCL 3'-10" CL 2'-4"4'-1"CL 1'-5" CL 4'-6"3'-5"2'-7"3"CL5'-3"CL 1'6"3'6'-3"7'-4"8'-2"9"HALL 10'-3" X 6'-3" MASTER BATH 13'-4" X 4'-0" BATHROOM 5'-11" X 6'-3" STAIRWELL 8'-11" X 2'-11"5'-1"2'-6"5'-9"4'-1" CL 7'-3"CL CL 3'-10"CL 2'-4"4'-1" CL1'-5"CL 4'-6"3'-5"2'-7"3" CL 5'-3" CL 1' 6"2'-7"10'-5"2'13'-4"11'-6"2'4"2'-4"8'-10"1'-1"3'-11"4'-8"1'-5"3'-11"6'2'-10"6'-2"2'-10"5"5'-1"8"8'-2"4"2'-7"8'-5"3'3' 6'-3"7'-4"8'-2" 15'-11"13'-4"9"2'-7"1'-3"HALL10'-3" X 6'-3"BEDROOM 28'-2" X 11'-4"CLOSET 36'-2" X 2'-9"BEDROOM 111'-5" X 9'-9"CLOSET 211'-5" X 2'-0"CLOSET 113'-4" X 2'-0"MASTER BEDROOM13'-4" X 13'-7"MASTER BATH13'-4" X 4'-0"BATHROOM5'-11" X 6'-3"STAIRWELL8'-11" X 2'-11"18"27"43" 24"24"24"38"30"18"38"18" 6'-5"2'-8"HALFT BATH 6'-6" X 2'-8" 1'-5"1'-4"1'-4"10"6"1'-4"1'-3"1'-5"1'-4"1'-4"1'-4"1'-4"1'-4"1'-4"9"7"1'-4"6"6'-8"2'-8" 2'-11" FAJdraftingsolutions 5234 RINEHART AVE INDIANAPOLIS, INDIANA, 46241 (317) 737-0202 (317) 401-9071 Ow ner FOR CONSTRUCTION THESE DRAWINGS AND ALL COPIES ARE AND SHALL REMAIN THE PROPERTY AND COPYRIGHT OF THE ARCHITECT AND SHALL NOT BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS, MECHANICAL OR ELECTRONIC, WITHOUT EXPRESS WRITTEN PERMISSION OF THE ARCHITECT. THEY SHALL BE USED ONLY WITH RESPECT TO THIS PROJECT AND ARE NOT TO BE USED ON ANY OTHER PROJECT OR WORK WITHOUT PRIOR WRITTEN PERMISSION FROM THE ARCHITECT. COPYRIGHT 2023, BY FAJ DraftingSolutions L.L.C ROHRERREMODELING1340 ROHRER RD,CARMEL,INDIANAIssue Date/ProjectStatusPROJECT NUMBER A-101 PROPOSED FRAMING PLAN DRAWN BY CHECKED BY 07222023 F.R CHECKER 8/1/2023 9:01:07 AMG:/Other computers/My Computer (1)/PROJECT/OPEN PROJECTS/1340 ROHRER RD - G: -- GENERIC_TEMPLATE_627_HANNIBAL_STALTHOUGH EVERY EFFORT HAS BEEN MADE IN PREPARING THESE PLANS AND CHECKING THEM FOR ACCURACY, THE CONTRACTOR MUST CHECK ALL DETAILS AND DIMENSIONS AND BE RESPONSIBLE FOR THE SAME FOR ALL GOVERNING CODES AND BUILDING PRACTICES. THESE DRAWINGS CONFORM TOGENERALLY ACCEPTED BUILDING PRACTICES; HOWEVER, STATE AND LOCAL CODES VARY WIDELY. THE DRAFTSMAN, FRANCISCO J RUBI, SHALL NOT BE HELD LIABLE FOR ANY ERRORS. ALL CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE STATE AND LOCAL CODES. DO NOT SCALE DRAWINGS, USE ONLY THEPRINTED DIMENSIONS. VERIFY WITH THE WINDOW MANUFACTURER ALL WINDOWS SIZES AND APPLICABLE EGRESS REQUIREMENTS. ALL DIMENSIONS ARE TAKEN FROM/TO ROUGH STUDS OF A DIMENSION OF EITHER 5 ½” (2X6 STUDS), 3 ½” (2X4 STUDS), OR TO THE OUTSIDE OF MASONRY. THE CONTRACTOR SHALLVERIFY ALL MECHANICAL AND ELECTRICAL REQUIREMENTS AND CLEARANCE. CONTRACTOR SHALL VERIFY ALL FLOOR AND ROOF BEARING LOCATIONS. CONTRACTOR SHALL VERIFY ALL BEAM AND HEADER SIZES FOR CODE COMPLIANCE. CITY STAMP FOR CITY USED FRAMING NOTESFRAMING N OTES 1.PROVIDE DOUBLE JSTS. UNDER ALL WALLS RUNNING PARALLEL TO JOISTS.. 2.PROVIDE POSITIVE VENTILATION AT EA. END OF EA. RAFTER SPACE AT VAULTED CEILING AREAS. 3.PROVIDE FIRE BLOCKING, DRAFT STOPS AND FIRE STOPS AS PER I.B.C. SEC. R502.12. 4.PROVIDE POSITIVE CONECTIONS AT EACH END OF ALL POSTS AND COLUMNS TO RESIST LATERAL DISPLACEMENT. 5.PROVIDE MIN. 3 STUDS UNDER ALL BEAM BEARING LOCATIONS 7. SUB FLOORING TO BE 3/4" T & G FIR PLYWOOD 1 LUMBER USED FOR FRAMING SHALL BE GRADE MARKED AND SHALL CONFORM TO THE SIZE, GRADE, AND SPAN TABLES SPECIFIED IN THE CODE. 2 WALL FRAMING SHALL BE DESIGNED AND CONSTRUCTED TO RESIST ALL LOADS IMPOSED ON THEM, INCLUDING WIND, SEISMIC, AND GRAVITY LOADS. 3 STUDS USED IN FRAMING SHALL NOT BE SPACED MORE THAN 24 INCHES ON CENTER, EXCEPT IN CERTAIN SPECIAL CASES AS ALLOWED BY THE CODE. 4 TOP PLATES AND SOLE PLATES SHALL BE AT LEAST TWO NOMINAL INCHES IN THICKNESS AND SHALL BE OF THE SAME WIDTH AS THE STUDS. 5 HEADERS SHALL BE PROVIDED OVER ALL OPENINGS IN EXTERIOR WALLS, AND SHALL BE DESIGNED AND CONSTRUCTED TO RESIST THE LOADS IMPOSED ON THEM. 6 BRACING SHALL BE PROVIDED AT ALL CORNERS, INTERSECTIONS, AND AT INTERVALS NOT EXCEEDING 25 FEET, AND SHALL BE DESIGNED AND CONSTRUCTED TO RESIST WIND AND SEISMIC LOADS. 7 NAILING SHALL BE IN ACCORDANCE WITH THE CODE REQUIREMENTS FOR SIZE, SPACING, AND LOCATION. 8 FIRE-BLOCKING SHALL BE PROVIDED IN ACCORDANCE WITH THE CODE REQUIREMENTS TO PREVENT THE SPREAD OF FIRE WITHIN CONCEALED SPACES IN WALL AND FLOOR ASSEMBLIES. 9 MOISTURE BARRIERS SHALL BE PROVIDED IN EXTERIOR WALLS IN ACCORDANCE WITH THE CODE REQUIREMENTS TO PREVENT THE PENETRATION OF MOISTURE INTO THE BUILDING ENVELOPE. 10 ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE INDIANA BUILDING CODE AND ANY APPLICABLE LOCAL CODES AND REGULATIONS. IMPORTANT NOTESIMPORTANT NOTES PROPOSED FRAMING PLAN 2nd FLOOR SCALE: 5/16" = 1' ENLARGED PROPOSED BATHROOMS SCALE: 1/2" = 1' ENLARGED KITCHEN PLAN SCALE: 1/2" = 1' ENLARGED PROPOSED HALF BATH SCALE: 1/2" = 1' WALL FRAMING DETAILS SCALE: 1/4" = 1' EXISTING ROOF SHINGLES WILL BE REMOVED AND DISPOSED OF IN ACCORDANCE WITH LOCAL REGULATIONS. NEW ASPHALT SHINGLES WILL THEN BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS AND THE IRC REQUIREMENTS FOR MINIMUM SLOPE, FASTENING, FLASHING, AND VENTILATION. ALL WORK WILL COMPLY WITH LOCAL BUILDING CODES AND REGULATIONS EXISTING SIDING WILL BE REMOVED AND DISPOSED OF IN ACCORDANCE WITH LOCAL REGULATIONS. A WATER- RESISTIVE BARRIER WILL BE INSTALLED OVER THE SHEATHING, FOLLOWED BY THE INSTALLATION OF NEW CEMENT BOARD SIDING IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS AND THE IRC REQUIREMENTS FOR APPROVED MATERIALS, WEATHER PROTECTION, AND VENTILATION. ALL CEMENT BOARD SIDING MATERIALS AND FASTENERS WILL COMPLY WITH LOCAL BUILDING CODES AND REGULATIONS. ANY NECESSARY TRIM, CAULKING, AND SEALANT WILL BE INSTALLED TO ENSURE A WEATHER-TIGHT INSTALLATION. (IRC 2018 R703) EXISTING ROOF SHINGLES WILL BE REMOVED AND DISPOSED OF IN ACCORDANCE WITH LOCAL REGULATIONS. NEW ASPHALT SHINGLES WILL THEN BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS AND THE IRC REQUIREMENTS FOR MINIMUM SLOPE, FASTENING, FLASHING, AND VENTILATION. ALL WORK WILL COMPLY WITH LOCAL BUILDING CODES AND REGULATIONS EXISTING SIDING WILL BE REMOVED AND DISPOSED OF IN ACCORDANCE WITH LOCAL REGULATIONS. A WATER-RESISTIVE BARRIER WILL BE INSTALLED OVER THE SHEATHING, FOLLOWED BY THE INSTALLATION OF NEW CEMENT BOARD SIDING IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS AND THE IRC REQUIREMENTS FOR APPROVED MATERIALS, WEATHER PROTECTION, AND VENTILATION. ALL CEMENT BOARD SIDING MATERIALS AND FASTENERS WILL COMPLY WITH LOCAL BUILDING CODES AND REGULATIONS. ANY NECESSARY TRIM, CAULKING, AND SEALANT WILL BE INSTALLED TO ENSURE A WEATHER-TIGHT INSTALLATION. (IRC 2018 R703) EXISTING ROOF SHINGLES WILL BE REMOVED AND DISPOSED OF IN ACCORDANCE WITH LOCAL REGULATIONS. NEW ASPHALT SHINGLES WILL THEN BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS AND THE IRC REQUIREMENTS FOR MINIMUM SLOPE, FASTENING, FLASHING, AND VENTILATION. ALL WORK WILL COMPLY WITH LOCAL BUILDING CODES AND REGULATIONS EXISTING SIDING WILL BE REMOVED AND DISPOSED OF IN ACCORDANCE WITH LOCAL REGULATIONS. A WATER- RESISTIVE BARRIER WILL BE INSTALLED OVER THE SHEATHING, FOLLOWED BY THE INSTALLATION OF NEW CEMENT BOARD SIDING IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS AND THE IRC REQUIREMENTS FOR APPROVED MATERIALS, WEATHER PROTECTION, AND VENTILATION. ALL CEMENT BOARD SIDING MATERIALS AND FASTENERS WILL COMPLY WITH LOCAL BUILDING CODES AND REGULATIONS. ANY NECESSARY TRIM, CAULKING, AND SEALANT WILL BE INSTALLED TO ENSURE A WEATHER-TIGHT INSTALLATION. (IRC 2018 R703) EXISTING ROOF SHINGLES WILL BE REMOVED AND DISPOSED OF IN ACCORDANCE WITH LOCAL REGULATIONS. NEW ASPHALT SHINGLES WILL THEN BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS AND THE IRC REQUIREMENTS FOR MINIMUM SLOPE, FASTENING, FLASHING, AND VENTILATION. ALL WORK WILL COMPLY WITH LOCAL BUILDING CODES AND REGULATIONS EXISTING SIDING WILL BE REMOVED AND DISPOSED OF IN ACCORDANCE WITH LOCAL REGULATIONS. A WATER- RESISTIVE BARRIER WILL BE INSTALLED OVER THE SHEATHING, FOLLOWED BY THE INSTALLATION OF NEW CEMENT BOARD SIDING IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS AND THE IRC REQUIREMENTS FOR APPROVED MATERIALS, WEATHER PROTECTION, AND VENTILATION. ALL CEMENT BOARD SIDING MATERIALS AND FASTENERS WILL COMPLY WITH LOCAL BUILDING CODES AND REGULATIONS. ANY NECESSARY TRIM, CAULKING, AND SEALANT WILL BE INSTALLED TO ENSURE A WEATHER-TIGHT INSTALLATION. (IRC 2018 R703) FAJdraftingsolutions 5234 RINEHART AVE INDIANAPOLIS, INDIANA, 46241 (317) 737-0202 (317) 401-9071 Ow ner FOR CONSTRUCTION THESE DRAWINGS AND ALL COPIES ARE AND SHALL REMAIN THE PROPERTY AND COPYRIGHT OF THE ARCHITECT AND SHALL NOT BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS, MECHANICAL OR ELECTRONIC, WITHOUT EXPRESS WRITTEN PERMISSION OF THE ARCHITECT. THEY SHALL BE USED ONLY WITH RESPECT TO THIS PROJECT AND ARE NOT TO BE USED ON ANY OTHER PROJECT OR WORK WITHOUT PRIOR WRITTEN PERMISSION FROM THE ARCHITECT. COPYRIGHT 2023, BY FAJ DraftingSolutions L.L.C ROHRERREMODELING1340 ROHRER RD,CARMEL,INDIANAIssue Date/ProjectStatusPROJECT NUMBER B-200 ELEVATIONS DRAWN BY CHECKED BY 07222023 F.R CHECKER 8/1/2023 9:01:40 AMG:/Other computers/My Computer (1)/PROJECT/OPEN PROJECTS/1340 ROHRER RD - G: -- GENERIC_TEMPLATE_627_HANNIBAL_STALTHOUGH EVERY EFFORT HAS BEEN MADE IN PREPARING THESE PLANS AND CHECKING THEM FOR ACCURACY, THE CONTRACTOR MUST CHECK ALL DETAILS AND DIMENSIONS AND BE RESPONSIBLE FOR THE SAME FOR ALL GOVERNING CODES AND BUILDING PRACTICES. THESE DRAWINGS CONFORM TOGENERALLY ACCEPTED BUILDING PRACTICES; HOWEVER, STATE AND LOCAL CODES VARY WIDELY. THE DRAFTSMAN, FRANCISCO J RUBI, SHALL NOT BE HELD LIABLE FOR ANY ERRORS. ALL CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE STATE AND LOCAL CODES. DO NOT SCALE DRAWINGS, USE ONLY THEPRINTED DIMENSIONS. VERIFY WITH THE WINDOW MANUFACTURER ALL WINDOWS SIZES AND APPLICABLE EGRESS REQUIREMENTS. ALL DIMENSIONS ARE TAKEN FROM/TO ROUGH STUDS OF A DIMENSION OF EITHER 5 ½” (2X6 STUDS), 3 ½” (2X4 STUDS), OR TO THE OUTSIDE OF MASONRY. THE CONTRACTOR SHALLVERIFY ALL MECHANICAL AND ELECTRICAL REQUIREMENTS AND CLEARANCE. CONTRACTOR SHALL VERIFY ALL FLOOR AND ROOF BEARING LOCATIONS. CONTRACTOR SHALL VERIFY ALL BEAM AND HEADER SIZES FOR CODE COMPLIANCE. CITY STAMP FOR CITY USED WEST ELEVATION SCALE: 1/4" = 1' SOUTH ELEVATION SCALE: 1/4" = 1' EAST ELEVATION SCALE: 1/4" = 1' NORTH ELEVATION SCALE: 1/4" = 1' GFCI GFCI GFCI CO/SD CO/SD CO/SD CO/SD CL CL 2'CL CL 8'CLCL 8'HALL10'-3" X 6'-3"BEDROOM 28'-2" X 11'-4"CLOSET 36'-2" X 2'-9"BEDROOM 111'-5" X 9'-9"CLOSET 211'-5" X 2'-0"CLOSET 113'-4" X 2'-0"MASTER BEDROOM13'-4" X 13'-7"MASTER BATH13'-4" X 4'-0"BATHROOM5'-11" X 6'-3"STAIRWELL8'-11" X 2'-11"3 33 3 CO/SD CO/SD CO/SD GFCI CL 5'-1"CL CL6'-4"CLCL 8' CLCL 8'CL CL6'-4"CL 2'-1"CL 2'-5"CL CL5'-10"CLCL 6'-4"EXISTING GARAGEEXISTING GARAGEEXISTING FIREPLACELIVING ROOM12'-3" X 11'-8"ENTRY5'-2" X 8'-0"KITCHEN12'-8" X 12'-0"DINING12'-5" X 27'-1"LAUNDRY12'-2" X 5'-1"MECHANICAL5'-10" X 13'-5"HALFT BATH6'-6" X 2'-8"FAJdraftingsolutions 5234 RINEHART AVE INDIANAPOLIS, INDIANA, 46241 (317) 737-0202 (317) 401-9071 Ow ner FOR CONSTRUCTION THESE DRAWINGS AND ALL COPIES ARE AND SHALL REMAIN THE PROPERTY AND COPYRIGHT OF THE ARCHITECT AND SHALL NOT BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS, MECHANICAL OR ELECTRONIC, WITHOUT EXPRESS WRITTEN PERMISSION OF THE ARCHITECT. THEY SHALL BE USED ONLY WITH RESPECT TO THIS PROJECT AND ARE NOT TO BE USED ON ANY OTHER PROJECT OR WORK WITHOUT PRIOR WRITTEN PERMISSION FROM THE ARCHITECT. COPYRIGHT 2023, BY FAJ DraftingSolutions L.L.C ROHRERREMODELING1340 ROHRER RD,CARMEL,INDIANAIssue Date/ProjectStatusPROJECT NUMBER E-300 PROPOSED ELECTRICAL PLAN DRAWN BY CHECKED BY 07222023 F.R CHECKER 8/1/2023 9:01:40 AMG:/Other computers/My Computer (1)/PROJECT/OPEN PROJECTS/1340 ROHRER RD - G: -- GENERIC_TEMPLATE_627_HANNIBAL_STALTHOUGH EVERY EFFORT HAS BEEN MADE IN PREPARING THESE PLANS AND CHECKING THEM FOR ACCURACY, THE CONTRACTOR MUST CHECK ALL DETAILS AND DIMENSIONS AND BE RESPONSIBLE FOR THE SAME FOR ALL GOVERNING CODES AND BUILDING PRACTICES. THESE DRAWINGS CONFORM TOGENERALLY ACCEPTED BUILDING PRACTICES; HOWEVER, STATE AND LOCAL CODES VARY WIDELY. THE DRAFTSMAN, FRANCISCO J RUBI, SHALL NOT BE HELD LIABLE FOR ANY ERRORS. ALL CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE STATE AND LOCAL CODES. DO NOT SCALE DRAWINGS, USE ONLY THEPRINTED DIMENSIONS. VERIFY WITH THE WINDOW MANUFACTURER ALL WINDOWS SIZES AND APPLICABLE EGRESS REQUIREMENTS. ALL DIMENSIONS ARE TAKEN FROM/TO ROUGH STUDS OF A DIMENSION OF EITHER 5 ½” (2X6 STUDS), 3 ½” (2X4 STUDS), OR TO THE OUTSIDE OF MASONRY. THE CONTRACTOR SHALLVERIFY ALL MECHANICAL AND ELECTRICAL REQUIREMENTS AND CLEARANCE. CONTRACTOR SHALL VERIFY ALL FLOOR AND ROOF BEARING LOCATIONS. CONTRACTOR SHALL VERIFY ALL BEAM AND HEADER SIZES FOR CODE COMPLIANCE. CITY STAMP FOR CITY USED GENERAL NOTESGENERAL NOTES 1.ELECTRICAL SERVICE: THE SERVICE ENTRANCE CONDUCTORS, RACEWAY, AND EQUIPMENT SHOULD BE INSTALLED IN ACCORDANCE WITH THE INDIANA ELECTRICAL CODE (IEC) AND NATIONAL ELECTRICAL CODE (NEC). THE SERVICE EQUIPMENT SHOULD BE LOCATED AND INSTALLED TO ENSURE SAFE AND RELIABLE OPERATION AND SHOULD COMPLY WITH INDIANA BUILDING CODE REQUIREMENTS. 2.BRANCH CIRCUITS: BRANCH CIRCUITS SHOULD BE INSTALLED IN ACCORDANCE WITH THE IEC AND NEC. THE MINIMUM SIZE OF BRANCH CIRCUITS SHOULD BE 15 AMPERES, EXCEPT FOR SPECIFIC APPLICATIONS SUCH AS AIR CONDITIONING OR ELECTRIC HEATING WHICH MAY REQUIRE LARGER CIRCUITS. THE MAXIMUM NUMBER OF OUTLETS OR LIGHTS THAT CAN BE CONNECTED TO A BRANCH CIRCUIT IS DETERMINED BY THE CIRCUIT AMPACIT Y, LOAD FACTORS, AND WIRE SIZE. 3.OUTLETS AND RECEPTACLES: OUTLETS AND RECEPTACLES SHOULD BE INSTALLED IN ACCORDANCE WITH THE IEC AND NEC. ALL OUTLETS SHOULD BE PROPERLY GROUNDED, POLARIZED, AND WIRED TO THE APPROPRIATE CIRCUIT. THE REQUIRED NUMBER OF OUTLETS IN A ROOM OR AREA IS BASED ON THE AREA OF THE ROOM OR AREA, AS SPECIFIED IN THE INDIANA BUILDING CODE. 4.LIGHTING: LIGHTING SHOULD BE INSTALLED IN ACCORDANCE WITH THE IEC AND NEC. ALL LIGHTING FIXTURES SHOULD BE PROPERLY GROUNDED AND WIRED TO THE APPROPRIATE CIRCUIT. THE REQUIRED NUMBER OF LIGHTING FIXTURES IN A ROOM OR AREA IS BASED ON THE AREA OF THE ROOM OR AREA, AS SPECIFIED IN THE INDIANA BUILDING CODE. 5.EMERGENCY POWER: IF REQUIRED BY THE INDIANA BUILDING CODE, EMERGENCY POWER SOURCES, SUCH AS A GENERATOR OR BATTERY BACKUP SYSTEM, SHOULD BE INSTALLED AND CONNECTED TO CRITICAL ELECTRICAL LOADS. THE EMERGENCY POWER SYSTEM SHOULD BE INSTALLED IN ACCORDANCE WITH THE IEC AND NEC. 6.GROUNDING AND BONDING: GROUNDING AND BONDING OF ELECTRICAL SYSTEMS, EQUIPMENT, AND CONDUCTIVE MATERIALS SHOULD BE IN ACCORDANCE WITH THE IEC AND NEC. THIS INCLUDES THE GROUNDING OF ELECTRICAL SERVICE EQUIPMENT, RACEWAYS, ENCLOSURES, AND CONDUCTORS. BONDING OF METAL PIPING, EQUIPMENT, AND STRUCTURES SHOULD ALSO BE IN ACCORDANCE WITH THE IEC AND NEC. 7.CONDUIT AND WIRING: CONDUIT AND WIRING SHOULD BE INSTALLED IN ACCORDANCE WITH THE IEC AND NEC. CONDUIT SHOULD BE SIZED APPROPRIATELY FOR THE NUMBER AND SIZE OF CONDUCTORS AND INSTALLED IN A NEAT AND WORKMANLIKE MANNER. WIRING SHOULD BE PROPERLY SUPPORTED AND SECURED, AND INSTALLED IN ACCORDANCE WITH THE IEC AND NEC. 8.SMOKE DETECTORS: SMOKE DETECTORS SHOULD BE INSTALLED IN ACCORDANCE WITH THE IEC AND NEC, AND THE INDIANA BUILDING CODE. SMOKE DETECTORS SHOULD BE INTERCONNECTED SO THAT ALL DETECTORS SOUND AN ALARM WHEN ONE IS ACTIVATED. THE REQUIRED NUMBER AND PLACEMENT OF SMOKE DETECTORS IS BASED ON THE SIZE AND LAYOUT OF THE BUILDING AND SPECIFIED IN THE INDIANA BUILDING CODE. 9. ELECTRICAL PANEL SCHEDULES: ELECTRICAL PANEL SCHEDULES SHOULD BE PROVIDED FOR EACH PANEL, SHOWING THE SIZE AND NUMBER OF CIRCUITS FOR EACH BREAKER OR FUSE, ALONG WITH THE AMPERAGE RATING OF THE PANEL AND THE MAXIMUM CURRENT RATING OF THE SERVICE ENTRANCE. THE PANEL SCHEDULES SHOULD BE LEGIBLE AND LOCATED NEAR THE PANEL. IMPORTANT NOTESIMPORTANT NOTES 1. E3402.1 DRILLING AND NOTCHING 1. E3402.1 DRILLING AND NOTCHING WOOD-FRAMED STRUCTURAL MEMBERS SHALL NOT BE DRILLED, NOTCHED OR ALTERED IN ANY MANNER EXCEPT AS PROVIDED FOR IN THIS CODE. E3402.2 PENETRATIONS OF FIRE-RESISTANCE-RATED ASSEMBLIESE3402.2 PENETRATIONS OF FIRE-RESISTANCE-RATED ASSEMBLIES ELECTRICAL INSTALLATIONS IN HOLLOW SPACES, VERTICAL SHAFTS AND VENTILATION OR AIR- HANDLING DUCTS SHALL BE MADE SO THAT THE POSSIBLE SPREAD OF FIRE OR PRODUCTS OF COMBUSTION WILL NOT BE SUBSTANTIALLY INCREASED. ELECTRICAL PENETRATIONS INTO OR THROUGH FIRE-RESISTANCE-RATED WALLS, PARTITIONS, FLOORS OR CEILINGS SHALL BE PROTECTED BY APPROVED METHODS TO MAINTAIN THE FIRE-RESISTANCE RATING OF THE ELEMENT PENETRATED. PENETRATIONS OF FIRE- RESISTANCE-RATED WALLS SHALL BE LIMITED AS SPECIFIED IN SECTION R302.4. (300.21) E3405.1 WORKING SPACE AND CLEARANCESR302.4. (300.21) E3405.1 WORKING SPACE AND CLEARANCES ACCESS AND WORKING SPACE SHALL BE PROVIDED AND MAINTAINED AROUND ALL ELECTRICAL EQUIPMENT TO PERMIT READY AND SAFE OPERATION AND MAINTENANCE OF SUCH EQUIPMENT IN ACCORDANCE WITH THIS SECTION AND FIGURE E3405.1.FIGURE E3405.1. FOR SI: 1 INCH = 25.4 MM, 1 FOOT = 304.8 MM. 1 EQUIPMENT, PIPING AND DUCTS FOREIGN TO THE ELECTRICAL INSTALLATION SHALL NOT BE PLACED IN THE SHADED AREAS EXTENDING FROM THE FLOOR TO A HEIGHT OF 6 FEET ABOVE THE PANELBOARD ENCLOSURE, OR TO THE STRUCTURAL CEILING, WHICHEVER IS LOWER. 2 THE WORKING SPACE SHALL BE CLEAR AND UNOBSTRUCTED FROM THE FLOOR TO A HEIGHT OF 6.5 FEET OR THE HEIGHT OF THE EQUIPMENT, WHICHEVER IS GREATER. 3 THE WORKING SPACE SHALL NOT BE DESIGNATED FOR STORAGE. 4 PANELBOARDS, SERVICE EQUIPMENT AND SIMILAR ENCLOSURES SHALL NOT BE LOCATED IN BATHROOMS, TOILET ROOMS, CLOTHES CLOSETS OR OVER THE STEPS OF A STAIRWAY. 5 SUCH WORK SPACES SHALL BE PROVIDED WITH ARTIFICIAL LIGHTING WHERE LOCATED INDOORS AND SHALL NOT BE CONTROLLED BY AUTOMATIC MEANS ONLY. FIGURE E3405.1A, B, C, D, E WORKING SPACE AND CLEARANCES FIGURE E3405.1. (110.26 ) NO TO SCALE 1ST FLOOR ELECTRICAL PLAN SCALE: 1/4" = 1'2ND FLOOR ELECTRICAL PLAN SCALE: 1/4" = 1' UPUPEXISTING GARAGEEXISTING GARAGEWWHHCCEXISTING FIREPLACELIVING ROOM12'-3" X 11'-8"ENTRY5'-2" X 8'-0"KITCHEN12'-8" X 12'-0"DINING12'-5" X 27'-1"LAUNDRY12'-2" X 5'-1"MECHANICAL5'-10" X 13'-5"HALFT BATH6'-6" X 2'-8"DNWWHHCCHALL10'-3" X 6'-3"BEDROOM 28'-2" X 11'-4"CLOSET 36'-2" X 2'-9"BEDROOM 111'-5" X 9'-9"CLOSET 211'-5" X 2'-0"CLOSET 113'-4" X 2'-0"MASTER BEDROOM13'-4" X 13'-7"MASTER BATH13'-4" X 4'-0"BATHROOM5'-11" X 6'-3"STAIRWELL8'-11" X 2'-11"PLUMBING LEDGEND COLD HOT WATER WASTE LINE CC HH WW CC HH WW FAJdraftingsolutions 5234 RINEHART AVE INDIANAPOLIS, INDIANA, 46241 (317) 737-0202 (317) 401-9071 Ow ner FOR CONSTRUCTION THESE DRAWINGS AND ALL COPIES ARE AND SHALL REMAIN THE PROPERTY AND COPYRIGHT OF THE ARCHITECT AND SHALL NOT BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS, MECHANICAL OR ELECTRONIC, WITHOUT EXPRESS WRITTEN PERMISSION OF THE ARCHITECT. THEY SHALL BE USED ONLY WITH RESPECT TO THIS PROJECT AND ARE NOT TO BE USED ON ANY OTHER PROJECT OR WORK WITHOUT PRIOR WRITTEN PERMISSION FROM THE ARCHITECT. COPYRIGHT 2023, BY FAJ DraftingSolutions L.L.C ROHRERREMODELING1340 ROHRER RD,CARMEL,INDIANAIssue Date/ProjectStatusPROJECT NUMBER F-400 PROPOSED PLUMBING /HVAC PLAN DRAWN BY CHECKED BY 07222023 F.R CHECKER 8/1/2023 9:01:41 AMG:/Other computers/My Computer (1)/PROJECT/OPEN PROJECTS/1340 ROHRER RD - G: -- GENERIC_TEMPLATE_627_HANNIBAL_STALTHOUGH EVERY EFFORT HAS BEEN MADE IN PREPARING THESE PLANS AND CHECKING THEM FOR ACCURACY, THE CONTRACTOR MUST CHECK ALL DETAILS AND DIMENSIONS AND BE RESPONSIBLE FOR THE SAME FOR ALL GOVERNING CODES AND BUILDING PRACTICES. THESE DRAWINGS CONFORM TOGENERALLY ACCEPTED BUILDING PRACTICES; HOWEVER, STATE AND LOCAL CODES VARY WIDELY. THE DRAFTSMAN, FRANCISCO J RUBI, SHALL NOT BE HELD LIABLE FOR ANY ERRORS. ALL CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE STATE AND LOCAL CODES. DO NOT SCALE DRAWINGS, USE ONLY THEPRINTED DIMENSIONS. VERIFY WITH THE WINDOW MANUFACTURER ALL WINDOWS SIZES AND APPLICABLE EGRESS REQUIREMENTS. ALL DIMENSIONS ARE TAKEN FROM/TO ROUGH STUDS OF A DIMENSION OF EITHER 5 ½” (2X6 STUDS), 3 ½” (2X4 STUDS), OR TO THE OUTSIDE OF MASONRY. THE CONTRACTOR SHALLVERIFY ALL MECHANICAL AND ELECTRICAL REQUIREMENTS AND CLEARANCE. CONTRACTOR SHALL VERIFY ALL FLOOR AND ROOF BEARING LOCATIONS. CONTRACTOR SHALL VERIFY ALL BEAM AND HEADER SIZES FOR CODE COMPLIANCE. CITY STAMP FOR CITY USED PLUMBING GENERAL NOTESPLUMBING GENERAL NOTES 1 ALL PLUMBING WORK SHOULD BE DONE IN ACCORDANCE WITH THE INDIANA PLUMBING CODE AND ANY APPLICABLE LOCAL CODES AND REGULATIONS. 2 ALL PLUMBING FIXTURES AND APPLIANCES SHOULD BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS AND THE CODE REQUIREMENTS. 3 ALL PLUMBING SYSTEMS SHOULD BE DESIGNED TO PREVENT BACKFLOW AND CONTAMINATION OF THE POTABLE WATER SUPPLY. THIS MAY INCLUDE THE INSTALLATION OF BACKFLOW PREVENTION DEVICES AND AIR GAPS. 4 ALL PIPES SHOULD BE PROPERLY SUPPORTED AND SECURED TO PREVENT DAMAGE AND ENSURE PROPER ALIGNMENT. 5 ALL PIPING MATERIALS SHOULD BE APPROPRIATE FOR THE INTENDED USE AND IN ACCORDANCE WITH THE CODE REQUIREMENTS. THIS MAY INCLUDE COPPER, PVC, PEX, OR OTHER MATERIALS. 6 ALL FITTINGS, VALVES, AND CONNECTORS SHOULD BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS AND THE CODE REQUIREMENTS. THIS MAY INCLUDE THE USE OF APPROVED MATERIALS, SIZES, AND T YPES OF FITTINGS. 7 ALL DRAINAGE AND VENTING SYSTEMS SHOULD BE DESIGNED AND INSTALLED TO PREVENT THE ESCAPE OF NOXIOUS GASES AND ODORS. THIS MAY INCLUDE THE INSTALLATION OF TRAPS, VENTS, AND CLEANOUTS. 8 ALL PLUMBING SYSTEMS SHOULD BE TESTED FOR LEAKS AND PROPER FUNCTION BEFORE THEY ARE PUT INTO SERVICE. 9 ALL PLUMBING WORK SHOULD BE INSPECTED BY THE LOCAL BUILDING DEPARTMENT TO ENSURE COMPLIANCE WITH THE CODE REQUIREMENTS AND ANY APPLICABLE LOCAL CODES AND REGULATIONS. 1 ALL HVAC WORK SHOULD BE DONE IN ACCORDANCE WITH THE INDIANA MECHANICAL CODE AND ANY APPLICABLE LOCAL CODES AND REGULATIONS. 2 ALL HVAC SYSTEMS SHOULD BE DESIGNED AND INSTALLED TO PROVIDE ADEQUATE HEATING, COOLING, AND VENTILATION FOR THE INTENDED SPACE OR BUILDING. 3 ALL HVAC EQUIPMENT SHOULD BE SELECTED BASED ON THE DESIGN REQUIREMENTS AND IN ACCORDANCE WITH THE CODE REQUIREMENTS. 4 ALL HVAC EQUIPMENT SHOULD BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS AND THE CODE REQUIREMENTS. THIS MAY INCLUDE THE USE OF APPROVED MATERIALS, SIZES, AND T YPES OF DUCTWORK, PIPING, AND ELECTRICAL CONNECTIONS. 5 ALL HVAC SYSTEMS SHOULD BE DESIGNED AND INSTALLED TO PROVIDE FOR PROPER AIR FLOW, INCLUDING THE SUPPLY AND RETURN AIR, AND TO MINIMIZE NOISE AND VIBRATION. 6 ALL HVAC EQUIPMENT SHOULD BE LOCATED AND INSTALLED TO PROVIDE FOR EASY ACCESS AND MAINTENANCE, AND TO PREVENT DAMAGE TO THE EQUIPMENT AND SURROUNDING AREAS. 7 ALL HVAC DUCT WORK SHOULD BE PROPERLY INSULATED AND SEALED TO PREVENT ENERGY LOSS AND AIR LEAKS. 8 ALL HVAC SYSTEMS SHOULD BE TESTED AND BALANCED TO ENSURE PROPER FUNCTION AND AIR FLOW. 9 ALL HVAC WORK SHOULD BE INSPECTED BY THE LOCAL BUILDING DEPARTMENT TO ENSURE COMPLIANCE WITH THE CODE REQUIREMENTS AND ANY APPLICABLE LOCAL CODES AND REGULATIONS. HVAC GENERAL NOTESHVAC GENERAL NOTES 1ST FLOOR HVAC/PLUMBING PLAN SCALE: 1/4" = 1' 2ND FLOOR HVAC/PLUMBING PLAN SCALE: 1/4" = 1' DOUBLE TOP PLATE 1/2" X 54" WALLBOARD 2x 4 SILL BOTTOM PLATE TYVEK HOUSE WRAP SHEATHING VINYL SIDING 2 X 4 EXTERIOR WALL 2X FLOOR JOISTS R-13 INSULATION 3/4" T&G SUBFLOOR 1/2" X 54" WALLBOARD 2X4 EXTERIOR WALL DETAILS (print at 1"=1') DRAINAGE SYSTEM TREATED SILL PLATE TERMITE FLASHING (optional) CMU BLOCKS CONCRETE FOOTING REINFORCING STEEL AS REQUIRED VAPOR BARRIER SHEATHING/SIDING INTERIOR FINISHFINISH FLOOR & TRIM 2x FLOOR JOISTS BATT INSULATION (crawlspace only) 2x RIM JOIST CAST-IN-PLACE ANCHOR BOLT SILL SEALER WOOD SUBFLOOR Typical CMU Crawl Space (print at 1"=1') 30” Min below grade 14" min 12" min 8" min 8”X12” WITH (3) #5 REBARS. ROOF FINISH DETAIL (print at 1"=1') SHINGLES WATER BARRIER MEMBRANE 1/2" PLYWOOD SHEETING 2X10 WOOD CORDS PRE-FINISH METAL DRIP EDGE PRE-FINISHED ALUMINUM GUTTER. REFERENCE ELEVATIONS FOR DOWNSPOUT LOCATIONS PROVIDE BRAKE METAL ALONG UNDERSIDE OF SOFFIT PROVIDE SOFFIT VENT 01 D-500 01 D-500 02 D-500 02 D-500 03 D-500 03 D-500 FAJdraftingsolutions 5234 RINEHART AVE INDIANAPOLIS, INDIANA, 46241 (317) 737-0202 (317) 401-9071 Ow ner FOR CONSTRUCTION THESE DRAWINGS AND ALL COPIES ARE AND SHALL REMAIN THE PROPERTY AND COPYRIGHT OF THE ARCHITECT AND SHALL NOT BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS, MECHANICAL OR ELECTRONIC, WITHOUT EXPRESS WRITTEN PERMISSION OF THE ARCHITECT. THEY SHALL BE USED ONLY WITH RESPECT TO THIS PROJECT AND ARE NOT TO BE USED ON ANY OTHER PROJECT OR WORK WITHOUT PRIOR WRITTEN PERMISSION FROM THE ARCHITECT. COPYRIGHT 2023, BY FAJ DraftingSolutions L.L.C ROHRERREMODELING1340 ROHRER RD,CARMEL,INDIANAIssue Date/ProjectStatusPROJECT NUMBER D-500 HOUSE OVERVIEW DETAILS DRAWN BY CHECKED BY 07222023 F.R CHECKER 8/1/2023 9:01:51 AMG:/Other computers/My Computer (1)/PROJECT/OPEN PROJECTS/1340 ROHRER RD - G: -- GENERIC_TEMPLATE_627_HANNIBAL_STALTHOUGH EVERY EFFORT HAS BEEN MADE IN PREPARING THESE PLANS AND CHECKING THEM FOR ACCURACY, THE CONTRACTOR MUST CHECK ALL DETAILS AND DIMENSIONS AND BE RESPONSIBLE FOR THE SAME FOR ALL GOVERNING CODES AND BUILDING PRACTICES. THESE DRAWINGS CONFORM TOGENERALLY ACCEPTED BUILDING PRACTICES; HOWEVER, STATE AND LOCAL CODES VARY WIDELY. THE DRAFTSMAN, FRANCISCO J RUBI, SHALL NOT BE HELD LIABLE FOR ANY ERRORS. ALL CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE STATE AND LOCAL CODES. DO NOT SCALE DRAWINGS, USE ONLY THEPRINTED DIMENSIONS. VERIFY WITH THE WINDOW MANUFACTURER ALL WINDOWS SIZES AND APPLICABLE EGRESS REQUIREMENTS. ALL DIMENSIONS ARE TAKEN FROM/TO ROUGH STUDS OF A DIMENSION OF EITHER 5 ½” (2X6 STUDS), 3 ½” (2X4 STUDS), OR TO THE OUTSIDE OF MASONRY. THE CONTRACTOR SHALLVERIFY ALL MECHANICAL AND ELECTRICAL REQUIREMENTS AND CLEARANCE. CONTRACTOR SHALL VERIFY ALL FLOOR AND ROOF BEARING LOCATIONS. CONTRACTOR SHALL VERIFY ALL BEAM AND HEADER SIZES FOR CODE COMPLIANCE. CITY STAMP FOR CITY USED 03 D-500 03 D-500 02 D-500 02 D-500 01 D-500 01 D-500 HOUSE OVERVIEW DETAILS SCALE: 1/4" = 1' FAJdraftingsolutions 5234 RINEHART AVE INDIANAPOLIS, INDIANA, 46241 (317) 737-0202 (317) 401-9071 Ow ner FOR CONSTRUCTION THESE DRAWINGS AND ALL COPIES ARE AND SHALL REMAIN THE PROPERTY AND COPYRIGHT OF THE ARCHITECT AND SHALL NOT BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS, MECHANICAL OR ELECTRONIC, WITHOUT EXPRESS WRITTEN PERMISSION OF THE ARCHITECT. THEY SHALL BE USED ONLY WITH RESPECT TO THIS PROJECT AND ARE NOT TO BE USED ON ANY OTHER PROJECT OR WORK WITHOUT PRIOR WRITTEN PERMISSION FROM THE ARCHITECT. COPYRIGHT 2023, BY FAJ DraftingSolutions L.L.C ROHRERREMODELING1340 ROHRER RD,CARMEL,INDIANAIssue Date/ProjectStatusPROJECT NUMBER D-501 RENDERING DRAWN BY CHECKED BY 07222023 F.R CHECKER 8/1/2023 9:01:51 AMG:/Other computers/My Computer (1)/PROJECT/OPEN PROJECTS/1340 ROHRER RD - G: -- GENERIC_TEMPLATE_627_HANNIBAL_STALTHOUGH EVERY EFFORT HAS BEEN MADE IN PREPARING THESE PLANS AND CHECKING THEM FOR ACCURACY, THE CONTRACTOR MUST CHECK ALL DETAILS AND DIMENSIONS AND BE RESPONSIBLE FOR THE SAME FOR ALL GOVERNING CODES AND BUILDING PRACTICES. THESE DRAWINGS CONFORM TOGENERALLY ACCEPTED BUILDING PRACTICES; HOWEVER, STATE AND LOCAL CODES VARY WIDELY. THE DRAFTSMAN, FRANCISCO J RUBI, SHALL NOT BE HELD LIABLE FOR ANY ERRORS. ALL CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE STATE AND LOCAL CODES. DO NOT SCALE DRAWINGS, USE ONLY THEPRINTED DIMENSIONS. VERIFY WITH THE WINDOW MANUFACTURER ALL WINDOWS SIZES AND APPLICABLE EGRESS REQUIREMENTS. ALL DIMENSIONS ARE TAKEN FROM/TO ROUGH STUDS OF A DIMENSION OF EITHER 5 ½” (2X6 STUDS), 3 ½” (2X4 STUDS), OR TO THE OUTSIDE OF MASONRY. THE CONTRACTOR SHALLVERIFY ALL MECHANICAL AND ELECTRICAL REQUIREMENTS AND CLEARANCE. CONTRACTOR SHALL VERIFY ALL FLOOR AND ROOF BEARING LOCATIONS. CONTRACTOR SHALL VERIFY ALL BEAM AND HEADER SIZES FOR CODE COMPLIANCE. CITY STAMP FOR CITY USED R E N DER IN G FO R I L LUST RAT I O N O N LYRENDERING FO R IL LUST RAT IO N O N LY RE N D E RIN G FO R IL LUST RATI O N ON LYRENDERING FO R I L LUST R AT I ON O N LY 1ST F LOO R1ST FLOO R FAJdraftingsolutions 5234 RINEHART AVE INDIANAPOLIS, INDIANA, 46241 (317) 737-0202 (317) 401-9071 Ow ner FOR CONSTRUCTION THESE DRAWINGS AND ALL COPIES ARE AND SHALL REMAIN THE PROPERTY AND COPYRIGHT OF THE ARCHITECT AND SHALL NOT BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS, MECHANICAL OR ELECTRONIC, WITHOUT EXPRESS WRITTEN PERMISSION OF THE ARCHITECT. THEY SHALL BE USED ONLY WITH RESPECT TO THIS PROJECT AND ARE NOT TO BE USED ON ANY OTHER PROJECT OR WORK WITHOUT PRIOR WRITTEN PERMISSION FROM THE ARCHITECT. COPYRIGHT 2023, BY FAJ DraftingSolutions L.L.C ROHRERREMODELING1340 ROHRER RD,CARMEL,INDIANAIssue Date/ProjectStatusPROJECT NUMBER D-502 RENDERING DRAWN BY CHECKED BY 07222023 F.R CHECKER 8/1/2023 9:01:51 AMG:/Other computers/My Computer (1)/PROJECT/OPEN PROJECTS/1340 ROHRER RD - G: -- GENERIC_TEMPLATE_627_HANNIBAL_STALTHOUGH EVERY EFFORT HAS BEEN MADE IN PREPARING THESE PLANS AND CHECKING THEM FOR ACCURACY, THE CONTRACTOR MUST CHECK ALL DETAILS AND DIMENSIONS AND BE RESPONSIBLE FOR THE SAME FOR ALL GOVERNING CODES AND BUILDING PRACTICES. THESE DRAWINGS CONFORM TOGENERALLY ACCEPTED BUILDING PRACTICES; HOWEVER, STATE AND LOCAL CODES VARY WIDELY. THE DRAFTSMAN, FRANCISCO J RUBI, SHALL NOT BE HELD LIABLE FOR ANY ERRORS. ALL CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE STATE AND LOCAL CODES. DO NOT SCALE DRAWINGS, USE ONLY THEPRINTED DIMENSIONS. VERIFY WITH THE WINDOW MANUFACTURER ALL WINDOWS SIZES AND APPLICABLE EGRESS REQUIREMENTS. ALL DIMENSIONS ARE TAKEN FROM/TO ROUGH STUDS OF A DIMENSION OF EITHER 5 ½” (2X6 STUDS), 3 ½” (2X4 STUDS), OR TO THE OUTSIDE OF MASONRY. THE CONTRACTOR SHALLVERIFY ALL MECHANICAL AND ELECTRICAL REQUIREMENTS AND CLEARANCE. CONTRACTOR SHALL VERIFY ALL FLOOR AND ROOF BEARING LOCATIONS. CONTRACTOR SHALL VERIFY ALL BEAM AND HEADER SIZES FOR CODE COMPLIANCE. CITY STAMP FOR CITY USED R E N DER IN G FO R I L LUST RAT I O N O N LYRENDERING FO R IL LUST RAT IO N O N LY RE N D E RIN G FO R IL LUST RATI O N ON LYRENDERING FO R I L LUST R AT I ON O N LY 2N D FLOO R2ND F LO OR FAJdraftingsolutions 5234 RINEHART AVE INDIANAPOLIS, INDIANA, 46241 (317) 737-0202 (317) 401-9071 Ow ner FOR CONSTRUCTION THESE DRAWINGS AND ALL COPIES ARE AND SHALL REMAIN THE PROPERTY AND COPYRIGHT OF THE ARCHITECT AND SHALL NOT BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS, MECHANICAL OR ELECTRONIC, WITHOUT EXPRESS WRITTEN PERMISSION OF THE ARCHITECT. THEY SHALL BE USED ONLY WITH RESPECT TO THIS PROJECT AND ARE NOT TO BE USED ON ANY OTHER PROJECT OR WORK WITHOUT PRIOR WRITTEN PERMISSION FROM THE ARCHITECT. COPYRIGHT 2023, BY FAJ DraftingSolutions L.L.C ROHRERREMODELING1340 ROHRER RD,CARMEL,INDIANAIssue Date/ProjectStatusPROJECT NUMBER D-503 RENDERING DRAWN BY CHECKED BY 07222023 F.R CHECKER 8/1/2023 9:01:51 AMG:/Other computers/My Computer (1)/PROJECT/OPEN PROJECTS/1340 ROHRER RD - G: -- GENERIC_TEMPLATE_627_HANNIBAL_STALTHOUGH EVERY EFFORT HAS BEEN MADE IN PREPARING THESE PLANS AND CHECKING THEM FOR ACCURACY, THE CONTRACTOR MUST CHECK ALL DETAILS AND DIMENSIONS AND BE RESPONSIBLE FOR THE SAME FOR ALL GOVERNING CODES AND BUILDING PRACTICES. THESE DRAWINGS CONFORM TOGENERALLY ACCEPTED BUILDING PRACTICES; HOWEVER, STATE AND LOCAL CODES VARY WIDELY. THE DRAFTSMAN, FRANCISCO J RUBI, SHALL NOT BE HELD LIABLE FOR ANY ERRORS. ALL CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE STATE AND LOCAL CODES. DO NOT SCALE DRAWINGS, USE ONLY THEPRINTED DIMENSIONS. VERIFY WITH THE WINDOW MANUFACTURER ALL WINDOWS SIZES AND APPLICABLE EGRESS REQUIREMENTS. ALL DIMENSIONS ARE TAKEN FROM/TO ROUGH STUDS OF A DIMENSION OF EITHER 5 ½” (2X6 STUDS), 3 ½” (2X4 STUDS), OR TO THE OUTSIDE OF MASONRY. THE CONTRACTOR SHALLVERIFY ALL MECHANICAL AND ELECTRICAL REQUIREMENTS AND CLEARANCE. CONTRACTOR SHALL VERIFY ALL FLOOR AND ROOF BEARING LOCATIONS. CONTRACTOR SHALL VERIFY ALL BEAM AND HEADER SIZES FOR CODE COMPLIANCE. CITY STAMP FOR CITY USED R E N DER IN G FO R I L LUST RAT I O N O N LYRENDERING FO R IL LUST RAT IO N O N LY FAJdraftingsolutions 5234 RINEHART AVE INDIANAPOLIS, INDIANA, 46241 (317) 737-0202 (317) 401-9071 Ow ner FOR CONSTRUCTION THESE DRAWINGS AND ALL COPIES ARE AND SHALL REMAIN THE PROPERTY AND COPYRIGHT OF THE ARCHITECT AND SHALL NOT BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS, MECHANICAL OR ELECTRONIC, WITHOUT EXPRESS WRITTEN PERMISSION OF THE ARCHITECT. THEY SHALL BE USED ONLY WITH RESPECT TO THIS PROJECT AND ARE NOT TO BE USED ON ANY OTHER PROJECT OR WORK WITHOUT PRIOR WRITTEN PERMISSION FROM THE ARCHITECT. COPYRIGHT 2023, BY FAJ DraftingSolutions L.L.C ROHRERREMODELING1340 ROHRER RD,CARMEL,INDIANAIssue Date/ProjectStatusPROJECT NUMBER D-504 RENDERING DRAWN BY CHECKED BY 07222023 F.R CHECKER 8/1/2023 9:01:51 AMG:/Other computers/My Computer (1)/PROJECT/OPEN PROJECTS/1340 ROHRER RD - G: -- GENERIC_TEMPLATE_627_HANNIBAL_STALTHOUGH EVERY EFFORT HAS BEEN MADE IN PREPARING THESE PLANS AND CHECKING THEM FOR ACCURACY, THE CONTRACTOR MUST CHECK ALL DETAILS AND DIMENSIONS AND BE RESPONSIBLE FOR THE SAME FOR ALL GOVERNING CODES AND BUILDING PRACTICES. THESE DRAWINGS CONFORM TOGENERALLY ACCEPTED BUILDING PRACTICES; HOWEVER, STATE AND LOCAL CODES VARY WIDELY. THE DRAFTSMAN, FRANCISCO J RUBI, SHALL NOT BE HELD LIABLE FOR ANY ERRORS. ALL CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE STATE AND LOCAL CODES. DO NOT SCALE DRAWINGS, USE ONLY THEPRINTED DIMENSIONS. VERIFY WITH THE WINDOW MANUFACTURER ALL WINDOWS SIZES AND APPLICABLE EGRESS REQUIREMENTS. ALL DIMENSIONS ARE TAKEN FROM/TO ROUGH STUDS OF A DIMENSION OF EITHER 5 ½” (2X6 STUDS), 3 ½” (2X4 STUDS), OR TO THE OUTSIDE OF MASONRY. THE CONTRACTOR SHALLVERIFY ALL MECHANICAL AND ELECTRICAL REQUIREMENTS AND CLEARANCE. CONTRACTOR SHALL VERIFY ALL FLOOR AND ROOF BEARING LOCATIONS. CONTRACTOR SHALL VERIFY ALL BEAM AND HEADER SIZES FOR CODE COMPLIANCE. CITY STAMP FOR CITY USEDRE NDERING FOR ILLUSTRATION ONLYRENDERING FOR ILLUSTRATION ONLY FAJdraftingsolutions 5234 RINEHART AVE INDIANAPOLIS, INDIANA, 46241 (317) 737-0202 (317) 401-9071 Ow ner FOR CONSTRUCTION THESE DRAWINGS AND ALL COPIES ARE AND SHALL REMAIN THE PROPERTY AND COPYRIGHT OF THE ARCHITECT AND SHALL NOT BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS, MECHANICAL OR ELECTRONIC, WITHOUT EXPRESS WRITTEN PERMISSION OF THE ARCHITECT. THEY SHALL BE USED ONLY WITH RESPECT TO THIS PROJECT AND ARE NOT TO BE USED ON ANY OTHER PROJECT OR WORK WITHOUT PRIOR WRITTEN PERMISSION FROM THE ARCHITECT. COPYRIGHT 2023, BY FAJ DraftingSolutions L.L.C ROHRERREMODELING1340 ROHRER RD,CARMEL,INDIANAIssue Date/ProjectStatusPROJECT NUMBER D-505 RENDERING DRAWN BY CHECKED BY 07222023 F.R CHECKER 8/1/2023 9:01:52 AMG:/Other computers/My Computer (1)/PROJECT/OPEN PROJECTS/1340 ROHRER RD - G: -- GENERIC_TEMPLATE_627_HANNIBAL_STALTHOUGH EVERY EFFORT HAS BEEN MADE IN PREPARING THESE PLANS AND CHECKING THEM FOR ACCURACY, THE CONTRACTOR MUST CHECK ALL DETAILS AND DIMENSIONS AND BE RESPONSIBLE FOR THE SAME FOR ALL GOVERNING CODES AND BUILDING PRACTICES. THESE DRAWINGS CONFORM TOGENERALLY ACCEPTED BUILDING PRACTICES; HOWEVER, STATE AND LOCAL CODES VARY WIDELY. THE DRAFTSMAN, FRANCISCO J RUBI, SHALL NOT BE HELD LIABLE FOR ANY ERRORS. ALL CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE STATE AND LOCAL CODES. DO NOT SCALE DRAWINGS, USE ONLY THEPRINTED DIMENSIONS. VERIFY WITH THE WINDOW MANUFACTURER ALL WINDOWS SIZES AND APPLICABLE EGRESS REQUIREMENTS. ALL DIMENSIONS ARE TAKEN FROM/TO ROUGH STUDS OF A DIMENSION OF EITHER 5 ½” (2X6 STUDS), 3 ½” (2X4 STUDS), OR TO THE OUTSIDE OF MASONRY. THE CONTRACTOR SHALLVERIFY ALL MECHANICAL AND ELECTRICAL REQUIREMENTS AND CLEARANCE. CONTRACTOR SHALL VERIFY ALL FLOOR AND ROOF BEARING LOCATIONS. CONTRACTOR SHALL VERIFY ALL BEAM AND HEADER SIZES FOR CODE COMPLIANCE. CITY STAMP FOR CITY USED R E N DERIN G FO R I L LUST RAT I O N O N LYRENDERING FO R IL LUST RAT IO N O N LY