HomeMy WebLinkAboutGENERIC_TEMPLATE_1340_ROHRER_RD_rev5.pdfFAJdraftingsolutions
5234 RINEHART AVE
INDIANAPOLIS, INDIANA, 46241
(317) 737-0202
(317) 401-9071
Ow ner
FOR
CONSTRUCTION
THESE DRAWINGS AND ALL COPIES ARE AND SHALL REMAIN THE PROPERTY AND
COPYRIGHT OF THE ARCHITECT AND SHALL NOT BE REPRODUCED IN WHOLE OR IN PART
BY ANY MEANS, MECHANICAL OR ELECTRONIC, WITHOUT EXPRESS WRITTEN
PERMISSION OF THE ARCHITECT. THEY SHALL BE USED ONLY WITH RESPECT TO THIS
PROJECT AND ARE NOT TO BE USED ON ANY OTHER PROJECT OR WORK WITHOUT
PRIOR WRITTEN PERMISSION FROM THE ARCHITECT. COPYRIGHT 2023, BY FAJ
DraftingSolutions L.L.C
ROHRERREMODELING1340 ROHRER RD,CARMEL,INDIANAIssue Date/ProjectStatusPROJECT
NUMBER
000-G
COVER SHEET
DRAWN BY
CHECKED BY
07222023
F.R
CHECKER
8/1/2023 9:01:06 AMG:/Other computers/My Computer (1)/PROJECT/OPEN PROJECTS/1340 ROHRER RD - G: -- GENERIC_TEMPLATE_627_HANNIBAL_ST134 0 ROHRER RD,CARMEL,INDIANA
STATE MAP VICINITY PLAN LOCATION PLAN INDEX / PLAN INFORMATION
INDEX OF DRAWINGS
COVER SHEET 000-G
GENERAL NOTES &SITE PLAN 001-G
DEMOLITION PLANS 002-G
PROPOSED 1ST & 2ND FLOOR A-100
PROPOSED FRAMING PLAN A-101
ELEVATIONS B-200
PROPOSED ELECTRICAL PLAN E-300
PROPOSED PLUMBING /HVAC PLAN F-400
HOUSE OVERVIEW DETAILS D-500
RENDERING D-501
RENDERING D-502
RENDERING D-503
RENDERING D-504
RENDERING D-505
ALTHOUGH EVERY EFFORT HAS BEEN MADE IN PREPARING THESE PLANS AND CHECKING THEM FOR ACCURACY, THE CONTRACTOR MUST CHECK ALL DETAILS AND DIMENSIONS AND BE RESPONSIBLE FOR THE SAME FOR ALL GOVERNING CODES AND BUILDING PRACTICES. THESE DRAWINGS CONFORM TOGENERALLY ACCEPTED BUILDING PRACTICES; HOWEVER, STATE AND LOCAL CODES VARY WIDELY. THE DRAFTSMAN, FRANCISCO J RUBI, SHALL NOT BE HELD LIABLE FOR ANY ERRORS. ALL CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE STATE AND LOCAL CODES. DO NOT SCALE DRAWINGS, USE ONLY THEPRINTED DIMENSIONS. VERIFY WITH THE WINDOW MANUFACTURER ALL WINDOWS SIZES AND APPLICABLE EGRESS REQUIREMENTS. ALL DIMENSIONS ARE TAKEN FROM/TO ROUGH STUDS OF A DIMENSION OF EITHER 5 ½” (2X6 STUDS), 3 ½” (2X4 STUDS), OR TO THE OUTSIDE OF MASONRY. THE CONTRACTOR SHALLVERIFY ALL MECHANICAL AND ELECTRICAL REQUIREMENTS AND CLEARANCE. CONTRACTOR SHALL VERIFY ALL FLOOR AND ROOF BEARING LOCATIONS. CONTRACTOR SHALL VERIFY ALL BEAM AND HEADER SIZES FOR CODE COMPLIANCE. CITY STAMP
FOR CITY USED
FAJdraftingsolutions
5234 RINEHART AVE
INDIANAPOLIS, INDIANA, 46241
(317) 737-0202
(317) 401-9071
Ow ner
FOR
CONSTRUCTION
THESE DRAWINGS AND ALL COPIES ARE AND SHALL REMAIN THE PROPERTY AND
COPYRIGHT OF THE ARCHITECT AND SHALL NOT BE REPRODUCED IN WHOLE OR IN PART
BY ANY MEANS, MECHANICAL OR ELECTRONIC, WITHOUT EXPRESS WRITTEN
PERMISSION OF THE ARCHITECT. THEY SHALL BE USED ONLY WITH RESPECT TO THIS
PROJECT AND ARE NOT TO BE USED ON ANY OTHER PROJECT OR WORK WITHOUT
PRIOR WRITTEN PERMISSION FROM THE ARCHITECT. COPYRIGHT 2023, BY FAJ
DraftingSolutions L.L.C
ROHRERREMODELING1340 ROHRER RD,CARMEL,INDIANAIssue Date/ProjectStatusPROJECT
NUMBER
001-G
GENERAL NOTES &
SITE PLAN
DRAWN BY
CHECKED BY
07222023
F.R
CHECKER
8/1/2023 9:01:06 AMG:/Other computers/My Computer (1)/PROJECT/OPEN PROJECTS/1340 ROHRER RD - G: -- GENERIC_TEMPLATE_627_HANNIBAL_STGENERAL NOTES
THE DRAWINGS INDICATE THE GENERAL SCOPE OF THE PROJECT IN TERMS OF ARCHITECTURAL DESIGN
CONCEPT, DIMENSIONS OF THE BUILDING, MAJOR ARCHITECTURAL ELEMENTS AND THE TYPE OF
STRUCTURAL SYSTEM. AS SCOPE REQUIRED FOR FULL PERFORMANCE AND COMPLETION OF THE
REQUIREMENTS OF THE CONTRACT DOCUMENTS. ON THE BASIS OF THE GENERAL SCOPE INDICATED
OR DESCRIBED, THE TRADE CONTRACTORS SHALL FURNISH ALL ITEMS REQUIRED FOR THE PROPER
EXECUTION AND COMPLETION OF THE WORK.
THESE CONTRACT DOCUMENTS DO NOT ATTEMPT TO INSTRUCT THE CONTRACTOR IN THE SPECIFIC
DETAILS OF HIS TRADE.
ALL WORK SHALL BE IN ACCORDANCE WITH THE QUALITY STANDARDS OF THE TRADE AND SHALL BE
INSTALLED IN COMPLIANCE, AS A MINIMUM STANDARD, TO ALL APPLICABLE LOCAL, STATE AND FEDERAL
CODES AND MANUFACTURER'S RECOMMENDATIONS.
ALL WORK SHALL BE WARRANTED SATISFACTORY, IN MATERIALS AND WORKMANSHIP, FOR A MINIMUM
PERIOD OF ONE (1) YEAR OR FOR THE CUSTOMARY PERIOD OF WARRANTY OR AS STIPULATED FOR THE
TRADE, CRAFT OR PRODUCT WHICHEVER IS LONGER
GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFICATION OF ALL DIMENSIONS AND JOB
CONDITIONS PRIOR TO STARTING CONSTRUCTION UNLESS OTHERWISE INDICATED. NOTIFY THE
ARCHITECT/ENGINEER OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH CONSTRUCTION.
THE COORDINATION OF ALL MATERIALS, LABOR AND WORKMANSHIP IS THE SOLE RESPONSIBILITY OF
THE GENERAL CONTRACTOR.
COMMENCING WORK BY A CONTRACTOR OR SUBCONTRACTOR CONSTITUTES ACCEPTANCE OF THE
CONDITIONS AND SURFACE CONCERNED. IF SUCH CONDITIONS OR SURFACES ARE UNACCEPTABLE, THE
GENERAL CONTRACTOR SHALL BE NOTIFIED IMMEDIATELY AND WORK SHOULD CEASE UNTIL THE
UNACCEPTABLE CONDITIONS CAN BE REMEDIED.
THE CONTRACTOR IS RESPONSIBLE FOR CONTACTING LOCAL BUILDING OFFICIALS AND INSPECTORS
FOR PERMITS AND INSPECTIONS. ADVISE THE ARCHITECT IMMEDIATELY OF AN DISCREPANCIES.
THE GENERAL CONTRACTOR IS SHALL PROVIDE A THOROUGH CONSTRUCTION CLEAN-UP PRIOR TO
OWNER/TENANT TAKING OCCUPANCY OF ANY SPACE. CLEAN-UP SHALL INCLUDE, BUT NOT BE LIMITED
TO CLEANING ALL SURFACES AND VACUUM AND CLEANING ALL CARPETING AND WINDOW TREATMENTS.
PROVIDE METAL OR FIRE RETARDANT TREATED WOOD BLOCKING IN NEW AND EXISTING WALLS FOR ALL
WALL SUPPORTED ITEMS. AT ALL EXISTING WALLS, PATCH AND REPAIR WALL FINISH TO MATCH
ADJACENT WALL SURFACE AS REQUIRED FOLLOWING THE INSTALLATION OF BLOCKING.
TRANSPORT TRASH, RUBBISH AND DEBRIS FROM THE SITE AND LEGALLY DISPOSE OF SAME. THE
MANNER OF REMOVAL MUST BE CONFIRMED WITH THE OWNER AND AS ALLOWED BY CITY AND STATE
REGULATIONS.
ALL DIMENSIONS ARE TAKEN FROM FACE OF STUD OR FACE OF BLOCK OR CONCRETE TO FACE OF STUD
OR FACE OF BLOCK OR CONCRETE, COLUMN LINES, UNLESS OTHERWISE SPECIFIED.
DO NOT SCALE DRAWINGS. REFER TO DIMENSIONS ILLUSTRATED ON DRAWINGS, NOTIFY THE
ARCHITECT/ENGINEER OF DISCREPANCIES FOR CLARIFICATION.
ALL STUD WALLS SHALL BE SECURED TO THE CONCRETE FLOOR AND CEILING OR FLOOR/ROOF
CONSTRUCTION ABOVE. PROVIDE EXPANSION/CONTROL JOINTS IN THE GYPSUM WALL BOARD WALLS
OVER 30'-0" IN LENGTH PER THE MANUFACTURER'S RECOMMENDATIONS. COORDINATE LOCATIONS OF
EXPANSION/CONTROL JOINTS WITH THE ARCHITECT PRIOR TO INSTALLATION FOR COMPLIANCE WITH
DESIGN INTENT.
ALL STUD OR MASONRY WALLS EXTENDING FROM FLOOR TO ROOF/FLOOR STRUCTURE ABOVE MUST
PROVIDE FOR A MINIMUM OF 2" VERTICAL ROOF/FLOOR DEFLECTION.
ALL JOINTS AND PENETRATIONS OF FIRE RATED ASSEMBLIES TO BE SEALED WITH APPROVED U.L.
LISTED "F" AND "T" SYSTEMS. SUBMIT PRODUCT DATA AND INSTALLATION INFORMATION PRIOR TO
INSTALLATION FOR ARCHITECTS APPROVAL.
FURNISH AND INSTALL PLUMBING FIXTURES AS SHOWN. ALL EXPOSED PIPING AND SUPPLY FITTINGS
SHALL BE CHROME PLATED UNLESS OTHERWISE INDICATED. ALL WALL PENETRATIONS SHALL BE FITTED
WITH CHROMIUM PLATED ESCUTCHEONS.
FIXTURES INDICATE AS HANDICAP ACCESSIBLE SHALL COMPLY WITH A.D.A. REQUIREMENTS.
HOT WATER AND DRAIN PIPES UNDER LAVATORIES AND HANDICAP ACCESSIBLE SINKS SHALL BE
INSTALLED OR OTHERWISE CONFIGURED TO PROTECT AGAINST CONTACT.
WHERE DISSIMILAR FLOOR MATERIALS MEET, THEY SHALL DO SO UNDER THE CENTERLINE OF A DOOR
UNLESS OTHERWISE INDICATED.
HINGE SIDE OF FINISH DOOR JAMB IN METAL STUD WALLS SHALL TYPICALLY BE LOCATED 6" FROM
ADJACENT FINISHED WALL UNLESS OTHERWISE INDICATED.
MATERIALS EXPOSED WITHIN PLENUM SPACES DESIGNED TO ALLOW AIR MOVEMENT AND FUNCTION AS
PART OF THE AIR DISTRIBUTION SYSTEM ARE REQUIRED TO BE NONCOMBUSTIBLE OR SHALL HAVE A
FLAME SPREAD INDEX LESS THAN 25 AND A SMOKE DEVELOPED INDEX LESS THAN 50 WHEN TESTED IN
ACCORDANCE WITH ASTM E 84.
APPLICATION OF FINISH COAT TO SURFACE INDICATES THAT CONTRACTOR HAS ACCEPTED SUBSTRATE
AS BEING SATISFACTORY.
ALL WALLS AROUND TOILET ROOMS ARE TO HAVE BATT INSULATION INSTALLED FULL DEPTH AND
HEIGHT.
THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE ACCURACY OF THE BUILDING LINES AND
LEVELS AND KEEPING THE STRUCTURE IN SQUARE. THE GENERAL CONTRACTOR SHALL COMPARE
CAREFULLY THE LINES AND LEVELS SHOWN ON THE DRAWINGS WITH EXISTING LEVELS FOR THE
CONSTRUCTION OF THE WORK. THEY SHALL CALL THE ARCHITECT'S ATTENTION TO ANY DISCREPANCIES
BEFORE PROCEEDING WITH ANY REQUIRED CORRECTION TO THE WORK.
ALL LUMBER IN CONTACT WITH CONCRETE MASONRY OR SOIL SHALL BE WATER RESISTANT PRESSURE
TREATED.
PROVIDE RODENT AND INSECT PROOFING WHERE ALL PLUMBING, WIRING, AND VENTS PASS THROUGH
PLATES, AS PER CODE REQUIREMENTS.
CONTACT RESPECTIVE UTILITY COMPANIES FOR EXACT LOCATIONS OF UNDERGROUND SERVICES
PRIOR TO START OF CONSTRUCTION. TAKE EVERY PRECAUTION NECESSARY TO PROTECT EXISTING
SERVICES DURING CONSTRUCTION.
REVIEW ALL DRAWINGS (ARCHITECTURAL, MECHANICAL, ELECTRICAL, STRUCTURAL), FOR ALL
INFORMATION CONCERNING SLEEVES, BOXES, ANCHORS, VENTS, OPENINGS, ETC., THAT MAY BE
REQUIRED. EACH RESPECTIVE TRADE IS RESPONSIBLE FOR PROVIDING AND INSTALLING THESE ITEMS.
CODE SUMMARY
EMERGENCY ESCAPE AND RESCUE OPENINGS
EVERY SLEEPING ROOM SHALL HAVE AT LEAST ONE
OPENABLE EMERGENCY ESCAPE AND RESCUE
OPENING
SMOKE ALARMS
REQUIRED SMOKE ALARM LOCATIONS:
LIVING AREA
ALL BEDROOMS OR SLEEPING AREAS
ON THE CEILING OF THE UPPER
LEVEL NEAR THE TOP OR ABOVE EACH STAIRWAY
BUILDING GROSS S.F
BASEMENT
_X
FIRST FLOOR
HALF BATH 20 SQ FT
ENTRY 52 SQ FT
DINING ROOM 400 SQ FT
KITCHEN 171 SQ FT
LIVING ROOM 159 SQ FT
FIRST FLOOR ROUGH TOTAL: 802 SQ FT
SECOND FLOOR
MASTER BEDROOM 195 SQ FT
BEDROOM 1 122 SQ FT
BEDROOM 2 104 SQ FT
MASTER BATH 46 SQ FT
BATHROOM 61 SQ FT
HALL 76 SQ FT
ATTIC
_X
GARAGE
GARAGE 800 SQ FT
ROUGH TOTAL : 2,206 SQ FT
ABBREVIATIONS
ACP ACOUSTIC CEILING PANEL
ACG ACOUSTIC CEILING GRID
ADJ ADJACENT
A.F.F. ABOVE FINISHED FLOOR
ALUM ALUMINUM
APC ACOUSTICAL PANEL CEILING
ASSBY ASSEMBLY
CLG CEILING
C.J. CONTROL JOINT
CLR CLEAR
CMU CONCRETE MASONRY UNIT
CONC CONCRETE
CONST CONSTRUCTION
DIA DIAMETER
DIV DIVISION
DWGS DRAWINGS
E.J. EXPANSION JOINT
ELEV ELEVATION
EQ EQUAL
ETC ETCETERA
EX/EXIST'G EXISTING
FD FLOOR DRAIN
FIN FINISH
GWB GYPSUM WALL BOARD
HM HOLLOW METAL
HR HOUR
JT. JOINT
LAM LAMINATE
MAT'L MATERIAL
MAX MAXIMUM
MFR MANUFACTURER
M.O. MASONRY OPENING
MIN MINIMUM
MTL METAL
N.I.C. NOT IN CONTRACT
OFCI OWNER FURNISHED CONTRACTOR
INSTALL
OFOI OWNER FURNISHED OWNER INSTALL
O.C. ON CENTER
O.H. OVERHEAD
OPP. OPPOSITE HAND
P-LAM PLASTIC LAMINATE
REF. REFERENCE, REFER TO
REQ'D REQUIRED
R.O. ROUGH OPENING
S.F. SQUARE FOOT
SHT LAM LAMINATE
MAT'L MATERIAL
MAX MAXIMUM
MFR MANUFACTURER
M.O. MASONRY OPENING
MIN MINIMUM
MTL METAL
N.I.C. NOT IN CONTRACT
OFCI OWNER FURNISHED CONTRACTOR
INSTALL
OFOI OWNER FURNISHED OWNER INSTALL
O.C. ON CENTER
O.H. OVERHEAD
OPP. OPPOSITE HAND
P-LAM PLASTIC LAMINATE
REF. REFERENCE, REFER TO
REQ'D REQUIRED
R.O. ROUGH OPENING
S.F. SQUARE FOOT
INDEX OF DRAWINGS
COVER SHEET 000-G
GENERAL NOTES &SITE PLAN 001-G
DEMOLITION PLANS 002-G
PROPOSED 1ST & 2ND FLOOR A-100
PROPOSED FRAMING PLAN A-101
ELEVATIONS B-200
PROPOSED ELECTRICAL PLAN E-300
PROPOSED PLUMBING /HVAC PLAN F-400
HOUSE OVERVIEW DETAILS D-500
RENDERING D-501
RENDERING D-502
RENDERING D-503
RENDERING D-504
RENDERING D-505
OWNER: Joe Real Estate Inc
PROJECT:RohrerRemodeling
ADDRESS:1340 ROHRER RD
LOCAL PARCEL #: 17-09-24-00-04-001.000
STATE PARCEL #: 29-09-24-004-001.000-018
ESTIMATED SQUARE FEET:
SECTION/TOWNSHIP/RANGE: TOWNSHIP 18
SUBDIVISION NAME:
CLASSIFICATION:RESIDENTIAL
LEGAL DESCRIPTION :
FIRE DISTRICT CARMEL FIRE DEPARTMENT
WATER/SEWER:CITY OF CARMEL UTILITIES
STORM WATER PERMIT: _____________________
BUILDING PERMIT: _____________________
DESIGNER: _____________________
DESIGN CONSULTANT:_____________________
BUILDER:_____________________
SITE DISTURBANCE:_____________________
ENGINEERING: _____________________
PROJECT NARRATIVE
THE PROPOSED SITE LOCATION IS 1340 ROHRER RD. PARCEL #11-10-01-02-04-003.00017-09-24-00-04-001.000
OPEN CASES:
_x
THE PROPOSED PROJECT INCLUDES:
- COMPLETE REMODELING OF 1ST FLOOR
- COMPLETE REMODELING OF 2ND FLOOR
- REMOVE SPECIFIC WALLS TO OPEN SPACE AND BUILD NEW FRAMING ( PLEASE REFER TO FLOOR PLANS
FOR MORE DETAILS)
- REMOVE WINDOWS AND REPLACE WITH NEW ONES. ( PLEASE REFER TO FLOOR PLANS FOR MORE DETAILS)
- REMOVE EXISTING SIDING AND INSTALL NEW ONE.
- REMOVE EXISTING ROOF SHINGLES AND INSTALL NEW ONES AS PER OWNER PREFERENCE.
- REPAIR EXISTING FLOOR AS NEEDED AND INSTALL NEW FLOOR FINISH AS PER OWNER PREFERENCE (
LAMINATED FLOORING, CARPET, TILE ,ETC)
- BUILD NEW BATHROOM IN 2ND FLOOR.
- CREATE NEW MASTER BATHROOM.
- NEW ELECTRICAL WIRING
- NEW PLUMBING SYSTEM
- NEW HVAC SYSTEM
ALTHOUGH EVERY EFFORT HAS BEEN MADE IN PREPARING THESE PLANS AND CHECKING THEM FOR ACCURACY, THE CONTRACTOR MUST CHECK ALL DETAILS AND DIMENSIONS AND BE RESPONSIBLE FOR THE SAME FOR ALL GOVERNING CODES AND BUILDING PRACTICES. THESE DRAWINGS CONFORM TOGENERALLY ACCEPTED BUILDING PRACTICES; HOWEVER, STATE AND LOCAL CODES VARY WIDELY. THE DRAFTSMAN, FRANCISCO J RUBI, SHALL NOT BE HELD LIABLE FOR ANY ERRORS. ALL CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE STATE AND LOCAL CODES. DO NOT SCALE DRAWINGS, USE ONLY THEPRINTED DIMENSIONS. VERIFY WITH THE WINDOW MANUFACTURER ALL WINDOWS SIZES AND APPLICABLE EGRESS REQUIREMENTS. ALL DIMENSIONS ARE TAKEN FROM/TO ROUGH STUDS OF A DIMENSION OF EITHER 5 ½” (2X6 STUDS), 3 ½” (2X4 STUDS), OR TO THE OUTSIDE OF MASONRY. THE CONTRACTOR SHALLVERIFY ALL MECHANICAL AND ELECTRICAL REQUIREMENTS AND CLEARANCE. CONTRACTOR SHALL VERIFY ALL FLOOR AND ROOF BEARING LOCATIONS. CONTRACTOR SHALL VERIFY ALL BEAM AND HEADER SIZES FOR CODE COMPLIANCE. CITY STAMP
FOR CITY USED
SITEPLAN
SCALE: 1/4" = 1'
22
22
EXISTING 2X4 WALL TO BE REMOVED TO
CREATE SPACE FOR NEW FRAMING.
CONTRACTOR TO PROVIDE TEMPORARY
SUPPORT FOR ANY LOAD-BEARING
ELEMENTS AFFECTED BY THE REMOVAL OF
THE WALL. THE NEW FRAMING SHALL BE
CONSTRUCTED IN ACCORDANCE WITH
LOCAL BUILDING CODES
EXISTING 2X4 WALL TO BE REMOVED TO
CREATE SPACE FOR NEW FRAMING.
CONTRACTOR TO PROVIDE TEMPORARY
SUPPORT FOR ANY LOAD-BEARING
ELEMENTS AFFECTED BY THE REMOVAL OF
THE WALL. THE NEW FRAMING SHALL BE
CONSTRUCTED IN ACCORDANCE WITH
LOCAL BUILDING CODES
11
11
11
FAJdraftingsolutions
5234 RINEHART AVE
INDIANAPOLIS, INDIANA, 46241
(317) 737-0202
(317) 401-9071
Ow ner
FOR
CONSTRUCTION
THESE DRAWINGS AND ALL COPIES ARE AND SHALL REMAIN THE PROPERTY AND
COPYRIGHT OF THE ARCHITECT AND SHALL NOT BE REPRODUCED IN WHOLE OR IN PART
BY ANY MEANS, MECHANICAL OR ELECTRONIC, WITHOUT EXPRESS WRITTEN
PERMISSION OF THE ARCHITECT. THEY SHALL BE USED ONLY WITH RESPECT TO THIS
PROJECT AND ARE NOT TO BE USED ON ANY OTHER PROJECT OR WORK WITHOUT
PRIOR WRITTEN PERMISSION FROM THE ARCHITECT. COPYRIGHT 2023, BY FAJ
DraftingSolutions L.L.C
ROHRERREMODELING1340 ROHRER RD,CARMEL,INDIANAIssue Date/ProjectStatusPROJECT
NUMBER
002-G
DEMOLITION PLANS
DRAWN BY
CHECKED BY
07222023
F.R
CHECKER
8/1/2023 9:01:06 AMG:/Other computers/My Computer (1)/PROJECT/OPEN PROJECTS/1340 ROHRER RD - G: -- GENERIC_TEMPLATE_627_HANNIBAL_STALTHOUGH EVERY EFFORT HAS BEEN MADE IN PREPARING THESE PLANS AND CHECKING THEM FOR ACCURACY, THE CONTRACTOR MUST CHECK ALL DETAILS AND DIMENSIONS AND BE RESPONSIBLE FOR THE SAME FOR ALL GOVERNING CODES AND BUILDING PRACTICES. THESE DRAWINGS CONFORM TOGENERALLY ACCEPTED BUILDING PRACTICES; HOWEVER, STATE AND LOCAL CODES VARY WIDELY. THE DRAFTSMAN, FRANCISCO J RUBI, SHALL NOT BE HELD LIABLE FOR ANY ERRORS. ALL CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE STATE AND LOCAL CODES. DO NOT SCALE DRAWINGS, USE ONLY THEPRINTED DIMENSIONS. VERIFY WITH THE WINDOW MANUFACTURER ALL WINDOWS SIZES AND APPLICABLE EGRESS REQUIREMENTS. ALL DIMENSIONS ARE TAKEN FROM/TO ROUGH STUDS OF A DIMENSION OF EITHER 5 ½” (2X6 STUDS), 3 ½” (2X4 STUDS), OR TO THE OUTSIDE OF MASONRY. THE CONTRACTOR SHALLVERIFY ALL MECHANICAL AND ELECTRICAL REQUIREMENTS AND CLEARANCE. CONTRACTOR SHALL VERIFY ALL FLOOR AND ROOF BEARING LOCATIONS. CONTRACTOR SHALL VERIFY ALL BEAM AND HEADER SIZES FOR CODE COMPLIANCE. CITY STAMP
FOR CITY USED
DEMOLITION 1ST FLOOR PLAN
SCALE: 1/4" = 1'
DEMOLITION NOTESDEMOLITION NOTES
1.COORDINATE THE EXTENT OF DEMOLITION WORK WITH ALL NEW CONSTRUCTION, AS INDICATED IN CONTRACT DOCUMENTS.
2.THESE DEMOLITION NOTES REPRESENT SURVEYED SPACES BEFORE DEMOLITION WORK. LOCATION OF CASEWORK,
COUNTERS, ETC. WITHIN THESE DOCUMENTS MAY NOT BE COMPLETELY ACCURATE. FIELD VERIFY THE EXACT SIZES AND
LOCATION OF ALL EXISTING WORK PRIOR TO CONSTRUCTION. CONTACT THE ARCHITECT IN THE EVENT OF CONFLICTS.
3.ALL DEMOLITION ITEMS SHALL BE CONSIDERED PROPERT Y OF THE OWNER UNTIL VERIFICATION HAS BEEN MADE AS TO ITEMS
TO BE RETAINED, PRIOR TO REMOVAL FROM THE SITE. ALL ITEMS NOT TO BE RETAINED SHALL BE REMOVED FROM THE SITE BY
THE CONTRACTOR.
4.CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO ENSURE THAT THE BUILDING REMAINS WATERTIGHT AND SECURE
AT ALL TIMES.
5.CONTRACTOR SHALL PROVIDE ALL TEMPORARY PARTITIONS AND DOORS AS DEEMED NECESSARY BY ARCHITECT AND OWNER
TO AVOID MIGRATION OF DUST INTO ADJOINING AND OCCUPIED AREAS.
6.PROTECT ALL EXISTING STRUCTURAL SUPPORTS.
7.MAKE ALL DEMOLITION CLEAN AND COMPLETE AND IN A MANNER SUITABLE TO ACCEPT NEW FINISHES AND/OR SURFACES.
8.WHEN DEMOLITION CAUSES OR EXPOSES DAMAGE TO EXISTING SLAB, FLOOR, WALL, OR CEILING SURFACES WHICH WILL
REMAIN EXPOSED IN THE FINISHED WORK, THE CONTRACTOR SHALL REPAIR AND LEVEL SUCH CONDITIONS AS REQUIRED.
9.REMOVE EXISTING FLOOR, WALL, AND CEILING FINISHES WITHIN BOUNDARY OF PROJECT SUITE. PROTECT ALL EXISTING
CORRIDOR INTERIOR FINISHES TO REMAIN.
10.WHERE ANY EXISTING PIPING OR DUCTWORK IN FLOORS, WALLS, OR CEILINGS IS TO BE REMOVED OR RELOCATED, FILL IN
PENETRATION OPENINGS FLUSH WITH AND OF THE SAME MATERIALS.
11.REFERENCE STRUCTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL DEMOLITION DRAWINGS FOR ADDITIONAL
INFORMATION, IN ACCORDANCE WITH INDIANA BUILDING CODE REGULATIONS AND STANDARDS.
12.REMOVAL OF ANY ASBESTOS IS THE RESPONSIBILIT Y OF THE OWNER, IN ACCORDANCE WITH INDIANA BUILDING CODE
SECTION 3310. NOTIFY THE ARCHITECT IF SUCH MATERIAL IS DISCOVERED DURING DEMOLITION OPERATIONS.
13.DASHED LINES INDICATE TO REMOVE WALLS, DOORS, FRAMES, AND ASSOCIATED ITEMS COMPLETE, IN ACCORDANCE WITH
INDIANA BUILDING CODE SECTION 3306.
1 SAFET Y FIRST: BEFORE BEGINNING ANY WORK ON ASBESTOS REMOVAL, ENSURE THAT ALL NECESSARY SAFET Y
PRECAUTIONS ARE TAKEN. THIS INCLUDES WEARING APPROPRIATE PERSONAL PROTECTIVE EQUIPMENT (PPE),
SUCH AS GLOVES, EYE PROTECTION, RESPIRATORY MASKS, AND FULL BODY SUITS.
2 ASBESTOS IDENTIFICATION: IDENTIFY ALL POTENTIAL SOURCES OF ASBESTOS-CONTAINING MATERIALS (ACMS)
BEFORE ANY REMOVAL WORK BEGINS. ONLY TRAINED PROFESSIONALS SHOULD PERFORM THE IDENTIFICATION
PROCESS.
3 COMPLIANCE: ENSURE THAT ALL ASBESTOS REMOVAL ACTIVITIES ARE IN COMPLIANCE WITH LOCAL, STATE, AND
FEDERAL REGULATIONS, INCLUDING PROPER LICENSING AND CERTIFICATIONS.
4 CONTAINMENT: ESTABLISH CONTAINMENT AREAS TO PREVENT THE RELEASE OF ASBESTOS FIBERS INTO THE
SURROUNDING ENVIRONMENT. THIS INCLUDES THE USE OF AIRLOCKS AND NEGATIVE AIR PRESSURE SYSTEMS.
5 REMOVAL TECHNIQUE: USE THE APPROPRIATE TECHNIQUES FOR REMOVING ASBESTOS-CONTAINING MATERIALS,
SUCH AS WET REMOVAL OR ENCAPSULATION.
6 WASTE DISPOSAL: ASBESTOS WASTE MUST BE PROPERLY PACKAGED AND LABELED, AND DISPOSED OF AT A
LICENSED LANDFILL. IT IS IMPORTANT TO FOLLOW ALL REGULATIONS AND GUIDELINES FOR ASBESTOS WASTE
DISPOSAL.
7 SITE RESTORATION: AFTER THE ASBESTOS-CONTAINING MATERIALS HAVE BEEN REMOVED, TAKE NECESSARY
STEPS TO RESTORE THE SITE TO ITS ORIGINAL CONDITION. THIS INCLUDES CLEANING THE AREA, AND ENSURING
THAT ALL SURFACES ARE FREE OF ASBESTOS FIBERS.
8 QUALIT Y CONTROL: ENSURE THAT THE FINISHED SURFACE MEETS THE REQUIRED SPECIFICATIONS, INCLUDING
SMOOTHNESS AND LEVELNESS.
9 COST ESTIMATION: CALCULATE THE COST OF THE ASBESTOS REMOVAL PROCESS, INCLUDING EQUIPMENT, LABOR,
DISPOSAL EXPENSES, AND ANY NECESSARY TESTING, TO ENSURE THAT THE PROJECT STAYS WITHIN BUDGET.
10 PROJECT TIMELINE: DEVELOP A REALISTIC TIMELINE FOR THE ASBESTOS REMOVAL PROCESS, TAKING INTO
ACCOUNT FACTORS SUCH AS WEATHER CONDITIONS AND ANY NECESSARY PERMITS OR APPROVALS. IT IS
IMPORTANT TO ADHERE TO THE TIMELINE TO MINIMIZE THE RISK OF ASBESTOS EXPOSURE.
SAFET Y NOTESSAFETY NOTES
DEMOLITION 2ND FLOOR PLAN
SCALE: 1/4" = 1'
EXISTING GARAGEEXISTING GARAGE
11
11
11
22
22
66
77
88
99
1010
10101111
44
EXISTING FIREPLACE
LIVING ROOM
12'-3" X 11'-8"
ENTRY
5'-2" X 8'-0"
KITCHEN
12'-8" X 12'-0"
DINING
12'-5" X 27'-1"
LAUNDRY
12'-2" X 5'-1"
MECHANICAL
5'-10" X 13'-5"
G05G05
G02G02
G04G04
G01G01
G06G06
G10G10
HALFT BATH
6'-6" X 2'-8"
G07G07
11
11
11
11
11
33
22
22
44
4411
55
55HALL
10'-3" X 6'-3"
BEDROOM 2
8'-2" X 11'-4"
CLOSET 3
6'-2" X 2'-9"
BEDROOM 1
11'-5" X 9'-9"
CLOSET 2
11'-5" X 2'-0"
CLOSET 1
13'-4" X 2'-0"
MASTER BEDROOM
13'-4" X 13'-7"
MASTER BATH
13'-4" X 4'-0"
BATHROOM
5'-11" X 6'-3"
STAIRWELL
8'-11" X 2'-11"
G13G13
G18G18
G11G11
G19G19
G12G12 G20G20
NOTE SCHEDULE
NEW INSTALLED DOOR AND FRAME. REFERENCE
DOOR & WINDOW SCHEDULE SHEET FOR DETAILS.
REPLACE EXISTING WINDOW WITH NEW WINDOW.
REFERENCE DOOR & WINDOW SCHEDULE SHEET
FOR DETAILS.
NEW INSTALLED WINDOW AND FRAME.
REFERENCE DOOR & WINDOW SCHEDULE SHEET
FOR DETAILS.
OWNER FURNISHED, CONTRACTOR INSTALLED
VANITY/SINK LOCATION. PROVIDE ALL
NECESSARY WATER LINE & PLUMBING
CONNECTION
OWNER FURNISHED, CONTRACTOR INSTALLED
STAND-UP SHOWER/BATH TUB LOCATION,
PROVIDE ALL NECESSARY WATER LINE &
PLUMBING CONNECTION
OWNER FURNISHED, CONTRACTOR INSTALLED
ELECTRIC STOVE AND OVEN, PROVIDE ALL
NECESSARY CONNECTIONS & 220V POWER
OUTLET.
OWNER FURNISHED, CONTRACTOR INSTALLED
KITCHEN SINK LOCATION, PROVIDE ALL
NECESSARY CONNECTIONS.
OWNER FURNISHED, CONTRACTOR INSTALLED
REFRIGERATOR CONNECTION, PROVIDE ALL
NECESSARY CONNECTIONS
OWNER FURNISHED, CONTRACTOR INSTALLED
WASHER & DRYER LOCATION, PROVIDE ALL
NECESSARY CONNECTIONS ALONG WITH 220A
POWER OUTLET
OWNER FURNISHED, CONTRACTOR INSTALLED
CABINETS / COUNTER TOP LOCATION.
OWNER FURNISHED, CONTRACTOR INSTALLED
ISLAND CABINETS / COUNTER TOP LOCATION.
WASTE LINE
11
22
33
44
55
66
77
88
99
1010
1111
WW
11
22
33
44
55
66
77
88
99
1010
1111
WW
ROOM SCHEDULE
NUMBER ROOM NAME AREA, STANDARD SQF ROOM TYPE
G01 DINING 400 DINING
G02 ENTRY 51 ENTRY
G04 KITCHEN 162 KITCHEN
G05 LIVING ROOM 159 LIVING
G06 LAUNDRY 9 LAUNDRY
G07 HALFT BATH 22 BATH
G08 LAUNDRY 69 LAUNDRY
G10 MECHANICAL 86 MECHANICAL
G11 BATHROOM 46 BATH
G12 BEDROOM 1 122 BEDROOM
G13 BEDROOM 2 104 BEDROOM
G18 HALL 76 HALL
G19 MASTER BATH 61 BATH
G20 MASTER
BEDROOM 195 BEDROOM
G21 STAIRWELL 30 OPEN BELOW
TOTALS: 1591
WALL LEDGEND
2D SYMBOL WALL TYPE DESCRIPTION
EXT1
EXTERIOR WALL, 2 X 4 WOOD
STUDS (PLACED 16" APART,
TYPICAL) WITH SOUND BATT
INSULATION IN CORE, 5 8"
PLYWOOD SHEETING BOARD, AND
12" CEMENT PANEL ON EXTERIO
INT1
INTERIOR WALL, 2 X 4 WOOD
STUDS (PLACED 16" APART,
TYPICAL) WITH 5 8" GYPSUM
WALL BOARD ON EXTERIOR SIDE
INTERIOR RAILING INTERIOR RAILING
ROOM DIVIDER ROOM DIVIDER
FAJdraftingsolutions
5234 RINEHART AVE
INDIANAPOLIS, INDIANA, 46241
(317) 737-0202
(317) 401-9071
Ow ner
FOR
CONSTRUCTION
THESE DRAWINGS AND ALL COPIES ARE AND SHALL REMAIN THE PROPERTY AND
COPYRIGHT OF THE ARCHITECT AND SHALL NOT BE REPRODUCED IN WHOLE OR IN PART
BY ANY MEANS, MECHANICAL OR ELECTRONIC, WITHOUT EXPRESS WRITTEN
PERMISSION OF THE ARCHITECT. THEY SHALL BE USED ONLY WITH RESPECT TO THIS
PROJECT AND ARE NOT TO BE USED ON ANY OTHER PROJECT OR WORK WITHOUT
PRIOR WRITTEN PERMISSION FROM THE ARCHITECT. COPYRIGHT 2023, BY FAJ
DraftingSolutions L.L.C
ROHRERREMODELING1340 ROHRER RD,CARMEL,INDIANAIssue Date/ProjectStatusPROJECT
NUMBER
A-100
PROPOSED 1ST &
2ND FLOOR
DRAWN BY
CHECKED BY
07222023
F.R
CHECKER
8/1/2023 9:01:06 AMG:/Other computers/My Computer (1)/PROJECT/OPEN PROJECTS/1340 ROHRER RD - G: -- GENERIC_TEMPLATE_627_HANNIBAL_STALTHOUGH EVERY EFFORT HAS BEEN MADE IN PREPARING THESE PLANS AND CHECKING THEM FOR ACCURACY, THE CONTRACTOR MUST CHECK ALL DETAILS AND DIMENSIONS AND BE RESPONSIBLE FOR THE SAME FOR ALL GOVERNING CODES AND BUILDING PRACTICES. THESE DRAWINGS CONFORM TOGENERALLY ACCEPTED BUILDING PRACTICES; HOWEVER, STATE AND LOCAL CODES VARY WIDELY. THE DRAFTSMAN, FRANCISCO J RUBI, SHALL NOT BE HELD LIABLE FOR ANY ERRORS. ALL CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE STATE AND LOCAL CODES. DO NOT SCALE DRAWINGS, USE ONLY THEPRINTED DIMENSIONS. VERIFY WITH THE WINDOW MANUFACTURER ALL WINDOWS SIZES AND APPLICABLE EGRESS REQUIREMENTS. ALL DIMENSIONS ARE TAKEN FROM/TO ROUGH STUDS OF A DIMENSION OF EITHER 5 ½” (2X6 STUDS), 3 ½” (2X4 STUDS), OR TO THE OUTSIDE OF MASONRY. THE CONTRACTOR SHALLVERIFY ALL MECHANICAL AND ELECTRICAL REQUIREMENTS AND CLEARANCE. CONTRACTOR SHALL VERIFY ALL FLOOR AND ROOF BEARING LOCATIONS. CONTRACTOR SHALL VERIFY ALL BEAM AND HEADER SIZES FOR CODE COMPLIANCE. CITY STAMP
FOR CITY USED
1- ALL CONSTRUCTION WORK MUST COMPLY WITH THE INDIANA RESIDENTIAL CODE AS WELL AS ANY APPLICABLE LOCAL BUILDING CODES AND ZONING REGULATIONS.
2- THE MAXIMUM HEIGHT OF A RESIDENTIAL BUILDING SHALL BE DETERMINED BY THE LOCAL ZONING CODE. 2 ALL FOUNDATIONS AND FOOTINGS MUST BE DESIGNED IN
ACCORDANCE WITH THE INDIANA RESIDENTIAL CODE.
3- ALL STRUCTURAL COMPONENTS SUCH AS WALLS, BEAMS, AND ROOF TRUSSES MUST BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH THE INDIANA RESIDENTIAL
CODE.
4- THE MINIMUM CLEAR HEIGHT OF HABITABLE ROOMS, HALLS, AND CORRIDORS SHALL BE 7 FEET (2134 MM).
5- EVERY DWELLING UNIT MUST HAVE AT LEAST ONE ROOM THAT MEASURES AT LEAST 120 SQUARE FEET (11.15 SQ. METERS) AND HAS A MINIMUM DIMENSION OF 10 FEET
(3048 MM).
6- EVERY DWELLING UNIT MUST HAVE AT LEAST ONE HABITABLE ROOM THAT HAS A WINDOW OR SKYLIGHT FACING DIRECTLY TO THE OUTDOORS, EXCEPT WHERE A ROOM IS
LOCATED IN A BASEMENT OR WHERE THE ROOM IS A BATHROOM, TOILET ROOM, OR KITCHEN.
7- ALL HABITABLE ROOMS MUST HAVE A MINIMUM OF ONE OPENABLE WINDOW OR EXTERIOR DOOR FOR NATURAL VENTILATION.
8- ALL PLUMBING FIXTURES MUST BE INSTALLED IN ACCORDANCE WITH THE INDIANA PLUMBING CODE.
9- ALL ELECTRICAL WORK MUST BE INSTALLED IN ACCORDANCE WITH THE INDIANA ELECTRICAL CODE.
10- SMOKE DETECTORS MUST BE INSTALLED IN ACCORDANCE WITH THE INDIANA RESIDENTIAL CODE.
11- CARBON MONOXIDE DETECTORS MUST BE INSTALLED IN ACCORDANCE WITH THE INDIANA RESIDENTIAL CODE.
12- ALL EXTERIOR DOORS MUST BE WEATHERSTRIPPED.
13- ALL GLAZING IN HAZARDOUS LOCATIONS, SUCH AS IN DOORS AND SHOWER ENCLOSURES, MUST MEET SAFET Y GLAZING REQUIREMENTS AS SPECIFIED IN THE INDIANA
RESIDENTIAL CODE.
14- ALL STAIRS MUST MEET THE MINIMUM REQUIREMENTS SPECIFIED IN THE INDIANA RESIDENTIAL CODE, INCLUDING MINIMUM TREAD AND RISER DIMENSIONS AND
HANDRAIL REQUIREMENTS.
15- ALL DECKS AND BALCONIES MUST BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH THE INDIANA RESIDENTIAL CODE.
16- ALL EXTERIOR WALLS MUST BE CONSTRUCTED TO RESIST WIND AND WATER PENETRATION.
17- ALL INSULATION MUST MEET THE MINIMUM R-VALUE REQUIREMENTS SPECIFIED IN THE INDIANA RESIDENTIAL CODE.
18- ALL ROOFING MATERIALS AND INSTALLATION METHODS MUST COMPLY WITH THE INDIANA RESIDENTIAL CODE
GENERAL NOT ESGENERAL N OTES
PROPOSED 1ST FLOOR PLAN
SCALE: 1/4" = 1'
PROPOSED 2nd FLOOR PLAN
SCALE: 1/4" = 1'
TYPICAL WINDOW HEADER DETAIL
(print at 1"=1')
WOOD FRAMING ASSEMBLY
WITH WEATHER STRIPPING
2X4 PLATE TO HEADER
CONNECTION IN
ACCORDANCE
WITH SECTION R602.7.1
1 1/2" X 3 1/2" PRE -
ENGINEERED
LVL BEAM
WATER / VAPOR BARRIER
TYPICAL EXTERIOR DOOR HEADER DETAIL
(print at 1"=1')
WOOD FRAMING ASSEMBLY
WITH WEATHER STRIPPING
2X4 PLATE TO HEADER
CONNECTION IN
ACCORDANCE
WITH SECTION R602.7.1
1 1/2" X 3 1/2" PRE -
ENGINEERED
LVL BEAM
WATER / VAPOR BARRIER
TYPICAL EXTERIOR DOOR JAMB DETAIL
(print at 1"=1')
2X4 FULL HEIGHT STUDS ON
EACH END IN ACCORDANCE
WITH COED TABLE R602.7.5.
FULL HEIGHT STUDS TO BE
NAILED TO BEAM WITH FOUR
16d
NAILS (3.5" X 0.135")
WATER / VAPOR BARRIER
2X4 WOOD JACK STUD GOING
ALL THE WAY TO THE HEADER
1/2 PLYWOOD SHEETING
BOARD
TYPICAL EXTERIOR WINDOW JAMB DETAIL
(print at 1"=1')
2X4 FULL HEIGHT STUDS ON
EACH END IN ACCORDANCE
WITH COED TABLE R602.7.5.
FULL HEIGHT STUDS TO BE
NAILED TO BEAM WITH FOUR
16d
NAILS (3.5" X 0.135")
WATER / VAPOR BARRIER
2X4 WOOD JACK STUD GOING
ALL THE WAY TO THE HEADER
1/2 PLYWOOD SHEETING
BOARD
TYPICAL INTERIOR DOOR HEADER DETAIL
(print at 1"=1')
WOOD FRAMING ASSEMBLY
WITH WEATHER STRIPPING
2X4 PLATE TO HEADER
CONNECTION IN
ACCORDANCE
WITH SECTION R602.7.1
1 1/2" X 3 1/2" PRE -
ENGINEERED
LVL BEAM
TYPICAL INTERIOR DOOR JAMB DETAIL
(print at 1"=1')
2X4 FULL HEIGHT STUDS ON
EACH END IN ACCORDANCE
WITH COED TABLE R602.7.5.
FULL HEIGHT STUDS TO BE
NAILED TO BEAM WITH FOUR
16d
NAILS (3.5" X 0.135")
1/2 GYPSUM WALL BOARD ON
BOTH SIDES
2X4 WOOD JACK STUD GOING
ALL THE WAY TO THE HEADER
TYPICAL EXTERIOR DOOR SILL DETAILS
(print at 1"=1')
EXTERIOR
CONCRETE
PATIO FLOOR
SEALANT
JOINT
EXTRUDED
ALUMINUM
THRESHOLD WOOD DOOR
ADJUSTABLE METAL
SILL
STEPFINISH
FLOOTING
PT WOOD OR COMPOSITE
SUB-SILL
GRADE
5'-1"2'-6"5'-9"4'-1"CL
7'-3"
CLCL
3'-10"
CL
2'-4"4'-1"CL
1'-5"
CL
4'-6"3'-5"2'-7"3"CL5'-3"CL
1'6"3'6'-3"7'-4"8'-2"9"HALL
10'-3" X 6'-3"
MASTER BATH
13'-4" X 4'-0"
BATHROOM
5'-11" X 6'-3"
STAIRWELL
8'-11" X 2'-11"5'-1"2'-6"5'-9"4'-1"
CL
7'-3"CL
CL
3'-10"CL 2'-4"4'-1"
CL1'-5"CL
4'-6"3'-5"2'-7"3"
CL
5'-3"
CL
1'
6"2'-7"10'-5"2'13'-4"11'-6"2'4"2'-4"8'-10"1'-1"3'-11"4'-8"1'-5"3'-11"6'2'-10"6'-2"2'-10"5"5'-1"8"8'-2"4"2'-7"8'-5"3'3'
6'-3"7'-4"8'-2"
15'-11"13'-4"9"2'-7"1'-3"HALL10'-3" X 6'-3"BEDROOM 28'-2" X 11'-4"CLOSET 36'-2" X 2'-9"BEDROOM 111'-5" X 9'-9"CLOSET 211'-5" X 2'-0"CLOSET 113'-4" X 2'-0"MASTER BEDROOM13'-4" X 13'-7"MASTER BATH13'-4" X 4'-0"BATHROOM5'-11" X 6'-3"STAIRWELL8'-11" X 2'-11"18"27"43"
24"24"24"38"30"18"38"18"
6'-5"2'-8"HALFT BATH
6'-6" X 2'-8"
1'-5"1'-4"1'-4"10"6"1'-4"1'-3"1'-5"1'-4"1'-4"1'-4"1'-4"1'-4"1'-4"9"7"1'-4"6"6'-8"2'-8"
2'-11"
FAJdraftingsolutions
5234 RINEHART AVE
INDIANAPOLIS, INDIANA, 46241
(317) 737-0202
(317) 401-9071
Ow ner
FOR
CONSTRUCTION
THESE DRAWINGS AND ALL COPIES ARE AND SHALL REMAIN THE PROPERTY AND
COPYRIGHT OF THE ARCHITECT AND SHALL NOT BE REPRODUCED IN WHOLE OR IN PART
BY ANY MEANS, MECHANICAL OR ELECTRONIC, WITHOUT EXPRESS WRITTEN
PERMISSION OF THE ARCHITECT. THEY SHALL BE USED ONLY WITH RESPECT TO THIS
PROJECT AND ARE NOT TO BE USED ON ANY OTHER PROJECT OR WORK WITHOUT
PRIOR WRITTEN PERMISSION FROM THE ARCHITECT. COPYRIGHT 2023, BY FAJ
DraftingSolutions L.L.C
ROHRERREMODELING1340 ROHRER RD,CARMEL,INDIANAIssue Date/ProjectStatusPROJECT
NUMBER
A-101
PROPOSED FRAMING
PLAN
DRAWN BY
CHECKED BY
07222023
F.R
CHECKER
8/1/2023 9:01:07 AMG:/Other computers/My Computer (1)/PROJECT/OPEN PROJECTS/1340 ROHRER RD - G: -- GENERIC_TEMPLATE_627_HANNIBAL_STALTHOUGH EVERY EFFORT HAS BEEN MADE IN PREPARING THESE PLANS AND CHECKING THEM FOR ACCURACY, THE CONTRACTOR MUST CHECK ALL DETAILS AND DIMENSIONS AND BE RESPONSIBLE FOR THE SAME FOR ALL GOVERNING CODES AND BUILDING PRACTICES. THESE DRAWINGS CONFORM TOGENERALLY ACCEPTED BUILDING PRACTICES; HOWEVER, STATE AND LOCAL CODES VARY WIDELY. THE DRAFTSMAN, FRANCISCO J RUBI, SHALL NOT BE HELD LIABLE FOR ANY ERRORS. ALL CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE STATE AND LOCAL CODES. DO NOT SCALE DRAWINGS, USE ONLY THEPRINTED DIMENSIONS. VERIFY WITH THE WINDOW MANUFACTURER ALL WINDOWS SIZES AND APPLICABLE EGRESS REQUIREMENTS. ALL DIMENSIONS ARE TAKEN FROM/TO ROUGH STUDS OF A DIMENSION OF EITHER 5 ½” (2X6 STUDS), 3 ½” (2X4 STUDS), OR TO THE OUTSIDE OF MASONRY. THE CONTRACTOR SHALLVERIFY ALL MECHANICAL AND ELECTRICAL REQUIREMENTS AND CLEARANCE. CONTRACTOR SHALL VERIFY ALL FLOOR AND ROOF BEARING LOCATIONS. CONTRACTOR SHALL VERIFY ALL BEAM AND HEADER SIZES FOR CODE COMPLIANCE. CITY STAMP
FOR CITY USED
FRAMING NOTESFRAMING N OTES
1.PROVIDE DOUBLE JSTS. UNDER ALL WALLS RUNNING PARALLEL TO JOISTS..
2.PROVIDE POSITIVE VENTILATION AT EA. END OF EA. RAFTER SPACE AT VAULTED CEILING AREAS.
3.PROVIDE FIRE BLOCKING, DRAFT STOPS AND FIRE STOPS AS PER I.B.C. SEC. R502.12.
4.PROVIDE POSITIVE CONECTIONS AT EACH END OF ALL POSTS AND COLUMNS TO RESIST
LATERAL DISPLACEMENT.
5.PROVIDE MIN. 3 STUDS UNDER ALL BEAM BEARING LOCATIONS 7. SUB FLOORING TO BE 3/4" T
& G FIR PLYWOOD
1 LUMBER USED FOR FRAMING SHALL BE GRADE MARKED AND SHALL CONFORM TO THE
SIZE, GRADE, AND SPAN TABLES SPECIFIED IN THE CODE.
2 WALL FRAMING SHALL BE DESIGNED AND CONSTRUCTED TO RESIST ALL LOADS
IMPOSED ON THEM, INCLUDING WIND, SEISMIC, AND GRAVITY LOADS. 3 STUDS USED IN
FRAMING SHALL NOT BE SPACED MORE THAN 24 INCHES ON CENTER, EXCEPT IN CERTAIN
SPECIAL CASES AS ALLOWED BY THE CODE.
4 TOP PLATES AND SOLE PLATES SHALL BE AT LEAST TWO NOMINAL INCHES IN THICKNESS
AND SHALL BE OF THE SAME WIDTH AS THE STUDS.
5 HEADERS SHALL BE PROVIDED OVER ALL OPENINGS IN EXTERIOR WALLS, AND SHALL BE
DESIGNED AND CONSTRUCTED TO RESIST THE LOADS IMPOSED ON THEM.
6 BRACING SHALL BE PROVIDED AT ALL CORNERS, INTERSECTIONS, AND AT INTERVALS
NOT EXCEEDING 25 FEET, AND SHALL BE DESIGNED AND CONSTRUCTED TO RESIST WIND
AND SEISMIC LOADS.
7 NAILING SHALL BE IN ACCORDANCE WITH THE CODE REQUIREMENTS FOR SIZE,
SPACING, AND LOCATION.
8 FIRE-BLOCKING SHALL BE PROVIDED IN ACCORDANCE WITH THE CODE REQUIREMENTS
TO PREVENT THE SPREAD OF FIRE WITHIN CONCEALED SPACES IN WALL AND FLOOR
ASSEMBLIES.
9 MOISTURE BARRIERS SHALL BE PROVIDED IN EXTERIOR WALLS IN ACCORDANCE WITH
THE CODE REQUIREMENTS TO PREVENT THE PENETRATION OF MOISTURE INTO THE
BUILDING ENVELOPE.
10 ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE INDIANA BUILDING CODE AND
ANY APPLICABLE LOCAL CODES AND REGULATIONS.
IMPORTANT NOTESIMPORTANT NOTES
PROPOSED FRAMING PLAN 2nd FLOOR
SCALE: 5/16" = 1'
ENLARGED PROPOSED BATHROOMS
SCALE: 1/2" = 1'
ENLARGED KITCHEN PLAN
SCALE: 1/2" = 1'
ENLARGED PROPOSED HALF BATH
SCALE: 1/2" = 1'
WALL FRAMING DETAILS
SCALE: 1/4" = 1'
EXISTING ROOF SHINGLES WILL BE REMOVED AND
DISPOSED OF IN ACCORDANCE WITH LOCAL REGULATIONS.
NEW ASPHALT SHINGLES WILL THEN BE INSTALLED IN
ACCORDANCE WITH THE MANUFACTURER'S
SPECIFICATIONS AND THE IRC REQUIREMENTS FOR
MINIMUM SLOPE, FASTENING, FLASHING, AND VENTILATION.
ALL WORK WILL COMPLY WITH LOCAL BUILDING CODES
AND REGULATIONS
EXISTING SIDING WILL BE REMOVED AND DISPOSED OF
IN ACCORDANCE WITH LOCAL REGULATIONS. A WATER-
RESISTIVE BARRIER WILL BE INSTALLED OVER THE
SHEATHING, FOLLOWED BY THE INSTALLATION OF NEW
CEMENT BOARD SIDING IN ACCORDANCE WITH THE
MANUFACTURER'S SPECIFICATIONS AND THE IRC
REQUIREMENTS FOR APPROVED MATERIALS, WEATHER
PROTECTION, AND VENTILATION. ALL CEMENT BOARD
SIDING MATERIALS AND FASTENERS WILL COMPLY WITH
LOCAL BUILDING CODES AND REGULATIONS. ANY
NECESSARY TRIM, CAULKING, AND SEALANT WILL BE
INSTALLED TO ENSURE A WEATHER-TIGHT
INSTALLATION. (IRC 2018 R703)
EXISTING ROOF SHINGLES WILL BE
REMOVED AND DISPOSED OF IN
ACCORDANCE WITH LOCAL
REGULATIONS. NEW ASPHALT SHINGLES
WILL THEN BE INSTALLED IN
ACCORDANCE WITH THE
MANUFACTURER'S SPECIFICATIONS AND
THE IRC REQUIREMENTS FOR MINIMUM
SLOPE, FASTENING, FLASHING, AND
VENTILATION. ALL WORK WILL COMPLY
WITH LOCAL BUILDING CODES AND
REGULATIONS
EXISTING SIDING WILL BE REMOVED AND DISPOSED OF IN ACCORDANCE WITH LOCAL
REGULATIONS. A WATER-RESISTIVE BARRIER WILL BE INSTALLED OVER THE
SHEATHING, FOLLOWED BY THE INSTALLATION OF NEW CEMENT BOARD SIDING IN
ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS AND THE IRC
REQUIREMENTS FOR APPROVED MATERIALS, WEATHER PROTECTION, AND
VENTILATION. ALL CEMENT BOARD SIDING MATERIALS AND FASTENERS WILL COMPLY
WITH LOCAL BUILDING CODES AND REGULATIONS. ANY NECESSARY TRIM, CAULKING,
AND SEALANT WILL BE INSTALLED TO ENSURE A WEATHER-TIGHT INSTALLATION. (IRC
2018 R703)
EXISTING ROOF SHINGLES WILL BE
REMOVED AND DISPOSED OF IN
ACCORDANCE WITH LOCAL
REGULATIONS. NEW ASPHALT SHINGLES
WILL THEN BE INSTALLED IN
ACCORDANCE WITH THE
MANUFACTURER'S SPECIFICATIONS AND
THE IRC REQUIREMENTS FOR MINIMUM
SLOPE, FASTENING, FLASHING, AND
VENTILATION. ALL WORK WILL COMPLY
WITH LOCAL BUILDING CODES AND
REGULATIONS
EXISTING SIDING WILL BE REMOVED AND DISPOSED OF IN
ACCORDANCE WITH LOCAL REGULATIONS. A WATER-
RESISTIVE BARRIER WILL BE INSTALLED OVER THE
SHEATHING, FOLLOWED BY THE INSTALLATION OF NEW
CEMENT BOARD SIDING IN ACCORDANCE WITH THE
MANUFACTURER'S SPECIFICATIONS AND THE IRC
REQUIREMENTS FOR APPROVED MATERIALS, WEATHER
PROTECTION, AND VENTILATION. ALL CEMENT BOARD SIDING
MATERIALS AND FASTENERS WILL COMPLY WITH LOCAL
BUILDING CODES AND REGULATIONS. ANY NECESSARY TRIM,
CAULKING, AND SEALANT WILL BE INSTALLED TO ENSURE A
WEATHER-TIGHT INSTALLATION. (IRC 2018 R703)
EXISTING ROOF SHINGLES WILL BE
REMOVED AND DISPOSED OF IN
ACCORDANCE WITH LOCAL
REGULATIONS. NEW ASPHALT SHINGLES
WILL THEN BE INSTALLED IN
ACCORDANCE WITH THE
MANUFACTURER'S SPECIFICATIONS AND
THE IRC REQUIREMENTS FOR MINIMUM
SLOPE, FASTENING, FLASHING, AND
VENTILATION. ALL WORK WILL COMPLY
WITH LOCAL BUILDING CODES AND
REGULATIONS
EXISTING SIDING WILL BE REMOVED AND DISPOSED OF IN
ACCORDANCE WITH LOCAL REGULATIONS. A WATER-
RESISTIVE BARRIER WILL BE INSTALLED OVER THE
SHEATHING, FOLLOWED BY THE INSTALLATION OF NEW
CEMENT BOARD SIDING IN ACCORDANCE WITH THE
MANUFACTURER'S SPECIFICATIONS AND THE IRC
REQUIREMENTS FOR APPROVED MATERIALS, WEATHER
PROTECTION, AND VENTILATION. ALL CEMENT BOARD SIDING
MATERIALS AND FASTENERS WILL COMPLY WITH LOCAL
BUILDING CODES AND REGULATIONS. ANY NECESSARY TRIM,
CAULKING, AND SEALANT WILL BE INSTALLED TO ENSURE A
WEATHER-TIGHT INSTALLATION. (IRC 2018 R703)
FAJdraftingsolutions
5234 RINEHART AVE
INDIANAPOLIS, INDIANA, 46241
(317) 737-0202
(317) 401-9071
Ow ner
FOR
CONSTRUCTION
THESE DRAWINGS AND ALL COPIES ARE AND SHALL REMAIN THE PROPERTY AND
COPYRIGHT OF THE ARCHITECT AND SHALL NOT BE REPRODUCED IN WHOLE OR IN PART
BY ANY MEANS, MECHANICAL OR ELECTRONIC, WITHOUT EXPRESS WRITTEN
PERMISSION OF THE ARCHITECT. THEY SHALL BE USED ONLY WITH RESPECT TO THIS
PROJECT AND ARE NOT TO BE USED ON ANY OTHER PROJECT OR WORK WITHOUT
PRIOR WRITTEN PERMISSION FROM THE ARCHITECT. COPYRIGHT 2023, BY FAJ
DraftingSolutions L.L.C
ROHRERREMODELING1340 ROHRER RD,CARMEL,INDIANAIssue Date/ProjectStatusPROJECT
NUMBER
B-200
ELEVATIONS
DRAWN BY
CHECKED BY
07222023
F.R
CHECKER
8/1/2023 9:01:40 AMG:/Other computers/My Computer (1)/PROJECT/OPEN PROJECTS/1340 ROHRER RD - G: -- GENERIC_TEMPLATE_627_HANNIBAL_STALTHOUGH EVERY EFFORT HAS BEEN MADE IN PREPARING THESE PLANS AND CHECKING THEM FOR ACCURACY, THE CONTRACTOR MUST CHECK ALL DETAILS AND DIMENSIONS AND BE RESPONSIBLE FOR THE SAME FOR ALL GOVERNING CODES AND BUILDING PRACTICES. THESE DRAWINGS CONFORM TOGENERALLY ACCEPTED BUILDING PRACTICES; HOWEVER, STATE AND LOCAL CODES VARY WIDELY. THE DRAFTSMAN, FRANCISCO J RUBI, SHALL NOT BE HELD LIABLE FOR ANY ERRORS. ALL CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE STATE AND LOCAL CODES. DO NOT SCALE DRAWINGS, USE ONLY THEPRINTED DIMENSIONS. VERIFY WITH THE WINDOW MANUFACTURER ALL WINDOWS SIZES AND APPLICABLE EGRESS REQUIREMENTS. ALL DIMENSIONS ARE TAKEN FROM/TO ROUGH STUDS OF A DIMENSION OF EITHER 5 ½” (2X6 STUDS), 3 ½” (2X4 STUDS), OR TO THE OUTSIDE OF MASONRY. THE CONTRACTOR SHALLVERIFY ALL MECHANICAL AND ELECTRICAL REQUIREMENTS AND CLEARANCE. CONTRACTOR SHALL VERIFY ALL FLOOR AND ROOF BEARING LOCATIONS. CONTRACTOR SHALL VERIFY ALL BEAM AND HEADER SIZES FOR CODE COMPLIANCE. CITY STAMP
FOR CITY USED
WEST ELEVATION
SCALE: 1/4" = 1'
SOUTH ELEVATION
SCALE: 1/4" = 1'
EAST ELEVATION
SCALE: 1/4" = 1'
NORTH ELEVATION
SCALE: 1/4" = 1'
GFCI
GFCI
GFCI
CO/SD
CO/SD
CO/SD
CO/SD
CL
CL
2'CL
CL
8'CLCL
8'HALL10'-3" X 6'-3"BEDROOM 28'-2" X 11'-4"CLOSET 36'-2" X 2'-9"BEDROOM 111'-5" X 9'-9"CLOSET 211'-5" X 2'-0"CLOSET 113'-4" X 2'-0"MASTER BEDROOM13'-4" X 13'-7"MASTER BATH13'-4" X 4'-0"BATHROOM5'-11" X 6'-3"STAIRWELL8'-11" X 2'-11"3
33
3
CO/SD
CO/SD
CO/SD
GFCI
CL
5'-1"CL
CL6'-4"CLCL
8'
CLCL
8'CL
CL6'-4"CL 2'-1"CL
2'-5"CL
CL5'-10"CLCL
6'-4"EXISTING GARAGEEXISTING GARAGEEXISTING FIREPLACELIVING ROOM12'-3" X 11'-8"ENTRY5'-2" X 8'-0"KITCHEN12'-8" X 12'-0"DINING12'-5" X 27'-1"LAUNDRY12'-2" X 5'-1"MECHANICAL5'-10" X 13'-5"HALFT BATH6'-6" X 2'-8"FAJdraftingsolutions
5234 RINEHART AVE
INDIANAPOLIS, INDIANA, 46241
(317) 737-0202
(317) 401-9071
Ow ner
FOR
CONSTRUCTION
THESE DRAWINGS AND ALL COPIES ARE AND SHALL REMAIN THE PROPERTY AND
COPYRIGHT OF THE ARCHITECT AND SHALL NOT BE REPRODUCED IN WHOLE OR IN PART
BY ANY MEANS, MECHANICAL OR ELECTRONIC, WITHOUT EXPRESS WRITTEN
PERMISSION OF THE ARCHITECT. THEY SHALL BE USED ONLY WITH RESPECT TO THIS
PROJECT AND ARE NOT TO BE USED ON ANY OTHER PROJECT OR WORK WITHOUT
PRIOR WRITTEN PERMISSION FROM THE ARCHITECT. COPYRIGHT 2023, BY FAJ
DraftingSolutions L.L.C
ROHRERREMODELING1340 ROHRER RD,CARMEL,INDIANAIssue Date/ProjectStatusPROJECT
NUMBER
E-300
PROPOSED
ELECTRICAL PLAN
DRAWN BY
CHECKED BY
07222023
F.R
CHECKER
8/1/2023 9:01:40 AMG:/Other computers/My Computer (1)/PROJECT/OPEN PROJECTS/1340 ROHRER RD - G: -- GENERIC_TEMPLATE_627_HANNIBAL_STALTHOUGH EVERY EFFORT HAS BEEN MADE IN PREPARING THESE PLANS AND CHECKING THEM FOR ACCURACY, THE CONTRACTOR MUST CHECK ALL DETAILS AND DIMENSIONS AND BE RESPONSIBLE FOR THE SAME FOR ALL GOVERNING CODES AND BUILDING PRACTICES. THESE DRAWINGS CONFORM TOGENERALLY ACCEPTED BUILDING PRACTICES; HOWEVER, STATE AND LOCAL CODES VARY WIDELY. THE DRAFTSMAN, FRANCISCO J RUBI, SHALL NOT BE HELD LIABLE FOR ANY ERRORS. ALL CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE STATE AND LOCAL CODES. DO NOT SCALE DRAWINGS, USE ONLY THEPRINTED DIMENSIONS. VERIFY WITH THE WINDOW MANUFACTURER ALL WINDOWS SIZES AND APPLICABLE EGRESS REQUIREMENTS. ALL DIMENSIONS ARE TAKEN FROM/TO ROUGH STUDS OF A DIMENSION OF EITHER 5 ½” (2X6 STUDS), 3 ½” (2X4 STUDS), OR TO THE OUTSIDE OF MASONRY. THE CONTRACTOR SHALLVERIFY ALL MECHANICAL AND ELECTRICAL REQUIREMENTS AND CLEARANCE. CONTRACTOR SHALL VERIFY ALL FLOOR AND ROOF BEARING LOCATIONS. CONTRACTOR SHALL VERIFY ALL BEAM AND HEADER SIZES FOR CODE COMPLIANCE. CITY STAMP
FOR CITY USED
GENERAL NOTESGENERAL NOTES
1.ELECTRICAL SERVICE: THE SERVICE ENTRANCE CONDUCTORS, RACEWAY, AND EQUIPMENT SHOULD BE INSTALLED IN
ACCORDANCE WITH THE INDIANA ELECTRICAL CODE (IEC) AND NATIONAL ELECTRICAL CODE (NEC). THE SERVICE
EQUIPMENT SHOULD BE LOCATED AND INSTALLED TO ENSURE SAFE AND RELIABLE OPERATION AND SHOULD
COMPLY WITH INDIANA BUILDING CODE REQUIREMENTS.
2.BRANCH CIRCUITS: BRANCH CIRCUITS SHOULD BE INSTALLED IN ACCORDANCE WITH THE IEC AND NEC. THE
MINIMUM SIZE OF BRANCH CIRCUITS SHOULD BE 15 AMPERES, EXCEPT FOR SPECIFIC APPLICATIONS SUCH AS AIR
CONDITIONING OR ELECTRIC HEATING WHICH MAY REQUIRE LARGER CIRCUITS. THE MAXIMUM NUMBER OF OUTLETS
OR LIGHTS THAT CAN BE CONNECTED TO A BRANCH CIRCUIT IS DETERMINED BY THE CIRCUIT AMPACIT Y, LOAD
FACTORS, AND WIRE SIZE.
3.OUTLETS AND RECEPTACLES: OUTLETS AND RECEPTACLES SHOULD BE INSTALLED IN ACCORDANCE WITH THE IEC
AND NEC. ALL OUTLETS SHOULD BE PROPERLY GROUNDED, POLARIZED, AND WIRED TO THE APPROPRIATE CIRCUIT.
THE REQUIRED NUMBER OF OUTLETS IN A ROOM OR AREA IS BASED ON THE AREA OF THE ROOM OR AREA, AS
SPECIFIED IN THE INDIANA BUILDING CODE.
4.LIGHTING: LIGHTING SHOULD BE INSTALLED IN ACCORDANCE WITH THE IEC AND NEC. ALL LIGHTING FIXTURES
SHOULD BE PROPERLY GROUNDED AND WIRED TO THE APPROPRIATE CIRCUIT. THE REQUIRED NUMBER OF LIGHTING
FIXTURES IN A ROOM OR AREA IS BASED ON THE AREA OF THE ROOM OR AREA, AS SPECIFIED IN THE INDIANA
BUILDING CODE.
5.EMERGENCY POWER: IF REQUIRED BY THE INDIANA BUILDING CODE, EMERGENCY POWER SOURCES, SUCH AS A
GENERATOR OR BATTERY BACKUP SYSTEM, SHOULD BE INSTALLED AND CONNECTED TO CRITICAL ELECTRICAL
LOADS. THE EMERGENCY POWER SYSTEM SHOULD BE INSTALLED IN ACCORDANCE WITH THE IEC AND NEC.
6.GROUNDING AND BONDING: GROUNDING AND BONDING OF ELECTRICAL SYSTEMS, EQUIPMENT, AND CONDUCTIVE
MATERIALS SHOULD BE IN ACCORDANCE WITH THE IEC AND NEC. THIS INCLUDES THE GROUNDING OF ELECTRICAL
SERVICE EQUIPMENT, RACEWAYS, ENCLOSURES, AND CONDUCTORS. BONDING OF METAL PIPING, EQUIPMENT, AND
STRUCTURES SHOULD ALSO BE IN ACCORDANCE WITH THE IEC AND NEC.
7.CONDUIT AND WIRING: CONDUIT AND WIRING SHOULD BE INSTALLED IN ACCORDANCE WITH THE IEC AND NEC.
CONDUIT SHOULD BE SIZED APPROPRIATELY FOR THE NUMBER AND SIZE OF CONDUCTORS AND INSTALLED IN A
NEAT AND WORKMANLIKE MANNER. WIRING SHOULD BE PROPERLY SUPPORTED AND SECURED, AND INSTALLED IN
ACCORDANCE WITH THE IEC AND NEC.
8.SMOKE DETECTORS: SMOKE DETECTORS SHOULD BE INSTALLED IN ACCORDANCE WITH THE IEC AND NEC, AND THE
INDIANA BUILDING CODE. SMOKE DETECTORS SHOULD BE INTERCONNECTED SO THAT ALL DETECTORS SOUND AN
ALARM WHEN ONE IS ACTIVATED. THE REQUIRED NUMBER AND PLACEMENT OF SMOKE DETECTORS IS BASED ON
THE SIZE AND LAYOUT OF THE BUILDING AND SPECIFIED IN THE INDIANA BUILDING CODE. 9. ELECTRICAL PANEL
SCHEDULES: ELECTRICAL PANEL SCHEDULES SHOULD BE PROVIDED FOR EACH PANEL, SHOWING THE SIZE AND
NUMBER OF CIRCUITS FOR EACH BREAKER OR FUSE, ALONG WITH THE AMPERAGE RATING OF THE PANEL AND THE
MAXIMUM CURRENT RATING OF THE SERVICE ENTRANCE. THE PANEL SCHEDULES SHOULD BE LEGIBLE AND
LOCATED NEAR THE PANEL.
IMPORTANT NOTESIMPORTANT NOTES
1. E3402.1 DRILLING AND NOTCHING 1. E3402.1 DRILLING AND NOTCHING
WOOD-FRAMED STRUCTURAL MEMBERS SHALL NOT BE DRILLED, NOTCHED OR ALTERED IN
ANY MANNER EXCEPT AS PROVIDED FOR IN THIS CODE.
E3402.2 PENETRATIONS OF FIRE-RESISTANCE-RATED ASSEMBLIESE3402.2 PENETRATIONS OF FIRE-RESISTANCE-RATED ASSEMBLIES
ELECTRICAL INSTALLATIONS IN HOLLOW SPACES, VERTICAL SHAFTS AND VENTILATION OR AIR-
HANDLING DUCTS SHALL BE MADE SO THAT THE POSSIBLE SPREAD OF FIRE OR PRODUCTS OF
COMBUSTION WILL NOT BE SUBSTANTIALLY INCREASED. ELECTRICAL PENETRATIONS INTO OR
THROUGH FIRE-RESISTANCE-RATED WALLS, PARTITIONS, FLOORS OR CEILINGS SHALL BE
PROTECTED BY APPROVED METHODS TO MAINTAIN THE FIRE-RESISTANCE RATING OF THE
ELEMENT PENETRATED. PENETRATIONS OF FIRE- RESISTANCE-RATED WALLS SHALL BE
LIMITED AS SPECIFIED IN SECTION
R302.4. (300.21) E3405.1 WORKING SPACE AND CLEARANCESR302.4. (300.21) E3405.1 WORKING SPACE AND CLEARANCES
ACCESS AND WORKING SPACE SHALL BE PROVIDED AND MAINTAINED AROUND ALL
ELECTRICAL EQUIPMENT TO PERMIT READY AND SAFE OPERATION AND MAINTENANCE OF
SUCH EQUIPMENT IN ACCORDANCE WITH THIS SECTION AND FIGURE E3405.1.FIGURE E3405.1.
FOR SI: 1 INCH = 25.4 MM, 1 FOOT = 304.8 MM.
1 EQUIPMENT, PIPING AND DUCTS FOREIGN TO THE ELECTRICAL INSTALLATION SHALL NOT BE PLACED IN THE
SHADED AREAS EXTENDING FROM THE FLOOR TO A HEIGHT OF 6 FEET ABOVE THE PANELBOARD ENCLOSURE, OR TO
THE STRUCTURAL CEILING, WHICHEVER IS LOWER.
2 THE WORKING SPACE SHALL BE CLEAR AND UNOBSTRUCTED FROM THE FLOOR TO A HEIGHT OF 6.5 FEET OR THE
HEIGHT OF THE EQUIPMENT, WHICHEVER IS GREATER.
3 THE WORKING SPACE SHALL NOT BE DESIGNATED FOR STORAGE.
4 PANELBOARDS, SERVICE EQUIPMENT AND SIMILAR ENCLOSURES SHALL NOT BE LOCATED IN BATHROOMS, TOILET
ROOMS, CLOTHES CLOSETS OR OVER THE STEPS OF A STAIRWAY.
5 SUCH WORK SPACES SHALL BE PROVIDED WITH ARTIFICIAL LIGHTING WHERE LOCATED INDOORS AND SHALL NOT
BE CONTROLLED BY AUTOMATIC MEANS ONLY. FIGURE E3405.1A, B, C, D, E WORKING SPACE AND CLEARANCES
FIGURE E3405.1. (110.26 )
NO TO SCALE
1ST FLOOR ELECTRICAL PLAN
SCALE: 1/4" = 1'2ND FLOOR ELECTRICAL PLAN
SCALE: 1/4" = 1'
UPUPEXISTING GARAGEEXISTING GARAGEWWHHCCEXISTING FIREPLACELIVING ROOM12'-3" X 11'-8"ENTRY5'-2" X 8'-0"KITCHEN12'-8" X 12'-0"DINING12'-5" X 27'-1"LAUNDRY12'-2" X 5'-1"MECHANICAL5'-10" X 13'-5"HALFT BATH6'-6" X 2'-8"DNWWHHCCHALL10'-3" X 6'-3"BEDROOM 28'-2" X 11'-4"CLOSET 36'-2" X 2'-9"BEDROOM 111'-5" X 9'-9"CLOSET 211'-5" X 2'-0"CLOSET 113'-4" X 2'-0"MASTER BEDROOM13'-4" X 13'-7"MASTER BATH13'-4" X 4'-0"BATHROOM5'-11" X 6'-3"STAIRWELL8'-11" X 2'-11"PLUMBING LEDGEND
COLD
HOT WATER
WASTE LINE
CC
HH
WW
CC
HH
WW
FAJdraftingsolutions
5234 RINEHART AVE
INDIANAPOLIS, INDIANA, 46241
(317) 737-0202
(317) 401-9071
Ow ner
FOR
CONSTRUCTION
THESE DRAWINGS AND ALL COPIES ARE AND SHALL REMAIN THE PROPERTY AND
COPYRIGHT OF THE ARCHITECT AND SHALL NOT BE REPRODUCED IN WHOLE OR IN PART
BY ANY MEANS, MECHANICAL OR ELECTRONIC, WITHOUT EXPRESS WRITTEN
PERMISSION OF THE ARCHITECT. THEY SHALL BE USED ONLY WITH RESPECT TO THIS
PROJECT AND ARE NOT TO BE USED ON ANY OTHER PROJECT OR WORK WITHOUT
PRIOR WRITTEN PERMISSION FROM THE ARCHITECT. COPYRIGHT 2023, BY FAJ
DraftingSolutions L.L.C
ROHRERREMODELING1340 ROHRER RD,CARMEL,INDIANAIssue Date/ProjectStatusPROJECT
NUMBER
F-400
PROPOSED
PLUMBING /HVAC
PLAN
DRAWN BY
CHECKED BY
07222023
F.R
CHECKER
8/1/2023 9:01:41 AMG:/Other computers/My Computer (1)/PROJECT/OPEN PROJECTS/1340 ROHRER RD - G: -- GENERIC_TEMPLATE_627_HANNIBAL_STALTHOUGH EVERY EFFORT HAS BEEN MADE IN PREPARING THESE PLANS AND CHECKING THEM FOR ACCURACY, THE CONTRACTOR MUST CHECK ALL DETAILS AND DIMENSIONS AND BE RESPONSIBLE FOR THE SAME FOR ALL GOVERNING CODES AND BUILDING PRACTICES. THESE DRAWINGS CONFORM TOGENERALLY ACCEPTED BUILDING PRACTICES; HOWEVER, STATE AND LOCAL CODES VARY WIDELY. THE DRAFTSMAN, FRANCISCO J RUBI, SHALL NOT BE HELD LIABLE FOR ANY ERRORS. ALL CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE STATE AND LOCAL CODES. DO NOT SCALE DRAWINGS, USE ONLY THEPRINTED DIMENSIONS. VERIFY WITH THE WINDOW MANUFACTURER ALL WINDOWS SIZES AND APPLICABLE EGRESS REQUIREMENTS. ALL DIMENSIONS ARE TAKEN FROM/TO ROUGH STUDS OF A DIMENSION OF EITHER 5 ½” (2X6 STUDS), 3 ½” (2X4 STUDS), OR TO THE OUTSIDE OF MASONRY. THE CONTRACTOR SHALLVERIFY ALL MECHANICAL AND ELECTRICAL REQUIREMENTS AND CLEARANCE. CONTRACTOR SHALL VERIFY ALL FLOOR AND ROOF BEARING LOCATIONS. CONTRACTOR SHALL VERIFY ALL BEAM AND HEADER SIZES FOR CODE COMPLIANCE. CITY STAMP
FOR CITY USED
PLUMBING GENERAL NOTESPLUMBING GENERAL NOTES
1 ALL PLUMBING WORK SHOULD BE DONE IN ACCORDANCE WITH THE INDIANA PLUMBING
CODE AND ANY APPLICABLE LOCAL CODES AND REGULATIONS.
2 ALL PLUMBING FIXTURES AND APPLIANCES SHOULD BE INSTALLED IN ACCORDANCE WITH
THE MANUFACTURER'S INSTRUCTIONS AND THE CODE REQUIREMENTS.
3 ALL PLUMBING SYSTEMS SHOULD BE DESIGNED TO PREVENT BACKFLOW AND
CONTAMINATION OF THE POTABLE WATER SUPPLY. THIS MAY INCLUDE THE INSTALLATION OF
BACKFLOW PREVENTION DEVICES AND AIR GAPS.
4 ALL PIPES SHOULD BE PROPERLY SUPPORTED AND SECURED TO PREVENT DAMAGE AND
ENSURE PROPER ALIGNMENT.
5 ALL PIPING MATERIALS SHOULD BE APPROPRIATE FOR THE INTENDED USE AND IN
ACCORDANCE WITH THE CODE REQUIREMENTS. THIS MAY INCLUDE COPPER, PVC, PEX, OR
OTHER MATERIALS.
6 ALL FITTINGS, VALVES, AND CONNECTORS SHOULD BE INSTALLED IN ACCORDANCE WITH
THE MANUFACTURER'S INSTRUCTIONS AND THE CODE REQUIREMENTS. THIS MAY INCLUDE
THE USE OF APPROVED MATERIALS, SIZES, AND T YPES OF FITTINGS.
7 ALL DRAINAGE AND VENTING SYSTEMS SHOULD BE DESIGNED AND INSTALLED TO
PREVENT THE ESCAPE OF NOXIOUS GASES AND ODORS. THIS MAY INCLUDE THE
INSTALLATION OF TRAPS, VENTS, AND CLEANOUTS.
8 ALL PLUMBING SYSTEMS SHOULD BE TESTED FOR LEAKS AND PROPER FUNCTION BEFORE
THEY ARE PUT INTO SERVICE.
9 ALL PLUMBING WORK SHOULD BE INSPECTED BY THE LOCAL BUILDING DEPARTMENT TO
ENSURE COMPLIANCE WITH THE CODE REQUIREMENTS AND ANY APPLICABLE LOCAL CODES
AND REGULATIONS.
1 ALL HVAC WORK SHOULD BE DONE IN ACCORDANCE WITH THE INDIANA MECHANICAL
CODE AND ANY APPLICABLE LOCAL CODES AND REGULATIONS.
2 ALL HVAC SYSTEMS SHOULD BE DESIGNED AND INSTALLED TO PROVIDE ADEQUATE
HEATING, COOLING, AND VENTILATION FOR THE INTENDED SPACE OR BUILDING.
3 ALL HVAC EQUIPMENT SHOULD BE SELECTED BASED ON THE DESIGN REQUIREMENTS AND
IN ACCORDANCE WITH THE CODE REQUIREMENTS.
4 ALL HVAC EQUIPMENT SHOULD BE INSTALLED IN ACCORDANCE WITH THE
MANUFACTURER'S INSTRUCTIONS AND THE CODE REQUIREMENTS. THIS MAY INCLUDE THE
USE OF APPROVED MATERIALS, SIZES, AND T YPES OF DUCTWORK, PIPING, AND ELECTRICAL
CONNECTIONS.
5 ALL HVAC SYSTEMS SHOULD BE DESIGNED AND INSTALLED TO PROVIDE FOR PROPER AIR
FLOW, INCLUDING THE SUPPLY AND RETURN AIR, AND TO MINIMIZE NOISE AND VIBRATION.
6 ALL HVAC EQUIPMENT SHOULD BE LOCATED AND INSTALLED TO PROVIDE FOR EASY
ACCESS AND MAINTENANCE, AND TO PREVENT DAMAGE TO THE EQUIPMENT AND
SURROUNDING AREAS.
7 ALL HVAC DUCT WORK SHOULD BE PROPERLY INSULATED AND SEALED TO PREVENT
ENERGY LOSS AND AIR LEAKS.
8 ALL HVAC SYSTEMS SHOULD BE TESTED AND BALANCED TO ENSURE PROPER FUNCTION
AND AIR FLOW.
9 ALL HVAC WORK SHOULD BE INSPECTED BY THE LOCAL BUILDING DEPARTMENT TO
ENSURE COMPLIANCE WITH THE CODE REQUIREMENTS AND ANY APPLICABLE LOCAL CODES
AND REGULATIONS.
HVAC GENERAL NOTESHVAC GENERAL NOTES
1ST FLOOR HVAC/PLUMBING PLAN
SCALE: 1/4" = 1'
2ND FLOOR HVAC/PLUMBING PLAN
SCALE: 1/4" = 1'
DOUBLE TOP PLATE
1/2" X 54" WALLBOARD
2x 4 SILL BOTTOM PLATE
TYVEK HOUSE WRAP
SHEATHING
VINYL SIDING
2 X 4 EXTERIOR WALL
2X FLOOR JOISTS
R-13 INSULATION
3/4" T&G SUBFLOOR
1/2" X 54" WALLBOARD
2X4 EXTERIOR WALL DETAILS
(print at 1"=1')
DRAINAGE SYSTEM
TREATED SILL PLATE
TERMITE FLASHING
(optional)
CMU BLOCKS
CONCRETE
FOOTING
REINFORCING STEEL AS REQUIRED
VAPOR BARRIER
SHEATHING/SIDING
INTERIOR
FINISHFINISH FLOOR & TRIM
2x FLOOR JOISTS
BATT INSULATION
(crawlspace only)
2x RIM JOIST
CAST-IN-PLACE ANCHOR BOLT
SILL SEALER
WOOD SUBFLOOR
Typical CMU Crawl Space
(print at 1"=1')
30” Min
below grade
14"
min
12"
min
8"
min
8”X12” WITH (3)
#5 REBARS.
ROOF FINISH DETAIL
(print at 1"=1')
SHINGLES
WATER BARRIER MEMBRANE
1/2" PLYWOOD SHEETING
2X10 WOOD CORDS
PRE-FINISH METAL
DRIP EDGE
PRE-FINISHED ALUMINUM
GUTTER. REFERENCE
ELEVATIONS FOR
DOWNSPOUT LOCATIONS
PROVIDE BRAKE METAL ALONG
UNDERSIDE OF SOFFIT
PROVIDE SOFFIT VENT
01
D-500
01
D-500
02
D-500
02
D-500
03
D-500
03
D-500
FAJdraftingsolutions
5234 RINEHART AVE
INDIANAPOLIS, INDIANA, 46241
(317) 737-0202
(317) 401-9071
Ow ner
FOR
CONSTRUCTION
THESE DRAWINGS AND ALL COPIES ARE AND SHALL REMAIN THE PROPERTY AND
COPYRIGHT OF THE ARCHITECT AND SHALL NOT BE REPRODUCED IN WHOLE OR IN PART
BY ANY MEANS, MECHANICAL OR ELECTRONIC, WITHOUT EXPRESS WRITTEN
PERMISSION OF THE ARCHITECT. THEY SHALL BE USED ONLY WITH RESPECT TO THIS
PROJECT AND ARE NOT TO BE USED ON ANY OTHER PROJECT OR WORK WITHOUT
PRIOR WRITTEN PERMISSION FROM THE ARCHITECT. COPYRIGHT 2023, BY FAJ
DraftingSolutions L.L.C
ROHRERREMODELING1340 ROHRER RD,CARMEL,INDIANAIssue Date/ProjectStatusPROJECT
NUMBER
D-500
HOUSE OVERVIEW
DETAILS
DRAWN BY
CHECKED BY
07222023
F.R
CHECKER
8/1/2023 9:01:51 AMG:/Other computers/My Computer (1)/PROJECT/OPEN PROJECTS/1340 ROHRER RD - G: -- GENERIC_TEMPLATE_627_HANNIBAL_STALTHOUGH EVERY EFFORT HAS BEEN MADE IN PREPARING THESE PLANS AND CHECKING THEM FOR ACCURACY, THE CONTRACTOR MUST CHECK ALL DETAILS AND DIMENSIONS AND BE RESPONSIBLE FOR THE SAME FOR ALL GOVERNING CODES AND BUILDING PRACTICES. THESE DRAWINGS CONFORM TOGENERALLY ACCEPTED BUILDING PRACTICES; HOWEVER, STATE AND LOCAL CODES VARY WIDELY. THE DRAFTSMAN, FRANCISCO J RUBI, SHALL NOT BE HELD LIABLE FOR ANY ERRORS. ALL CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE STATE AND LOCAL CODES. DO NOT SCALE DRAWINGS, USE ONLY THEPRINTED DIMENSIONS. VERIFY WITH THE WINDOW MANUFACTURER ALL WINDOWS SIZES AND APPLICABLE EGRESS REQUIREMENTS. ALL DIMENSIONS ARE TAKEN FROM/TO ROUGH STUDS OF A DIMENSION OF EITHER 5 ½” (2X6 STUDS), 3 ½” (2X4 STUDS), OR TO THE OUTSIDE OF MASONRY. THE CONTRACTOR SHALLVERIFY ALL MECHANICAL AND ELECTRICAL REQUIREMENTS AND CLEARANCE. CONTRACTOR SHALL VERIFY ALL FLOOR AND ROOF BEARING LOCATIONS. CONTRACTOR SHALL VERIFY ALL BEAM AND HEADER SIZES FOR CODE COMPLIANCE. CITY STAMP
FOR CITY USED
03
D-500
03
D-500
02
D-500
02
D-500
01
D-500
01
D-500
HOUSE OVERVIEW DETAILS
SCALE: 1/4" = 1'
FAJdraftingsolutions
5234 RINEHART AVE
INDIANAPOLIS, INDIANA, 46241
(317) 737-0202
(317) 401-9071
Ow ner
FOR
CONSTRUCTION
THESE DRAWINGS AND ALL COPIES ARE AND SHALL REMAIN THE PROPERTY AND
COPYRIGHT OF THE ARCHITECT AND SHALL NOT BE REPRODUCED IN WHOLE OR IN PART
BY ANY MEANS, MECHANICAL OR ELECTRONIC, WITHOUT EXPRESS WRITTEN
PERMISSION OF THE ARCHITECT. THEY SHALL BE USED ONLY WITH RESPECT TO THIS
PROJECT AND ARE NOT TO BE USED ON ANY OTHER PROJECT OR WORK WITHOUT
PRIOR WRITTEN PERMISSION FROM THE ARCHITECT. COPYRIGHT 2023, BY FAJ
DraftingSolutions L.L.C
ROHRERREMODELING1340 ROHRER RD,CARMEL,INDIANAIssue Date/ProjectStatusPROJECT
NUMBER
D-501
RENDERING
DRAWN BY
CHECKED BY
07222023
F.R
CHECKER
8/1/2023 9:01:51 AMG:/Other computers/My Computer (1)/PROJECT/OPEN PROJECTS/1340 ROHRER RD - G: -- GENERIC_TEMPLATE_627_HANNIBAL_STALTHOUGH EVERY EFFORT HAS BEEN MADE IN PREPARING THESE PLANS AND CHECKING THEM FOR ACCURACY, THE CONTRACTOR MUST CHECK ALL DETAILS AND DIMENSIONS AND BE RESPONSIBLE FOR THE SAME FOR ALL GOVERNING CODES AND BUILDING PRACTICES. THESE DRAWINGS CONFORM TOGENERALLY ACCEPTED BUILDING PRACTICES; HOWEVER, STATE AND LOCAL CODES VARY WIDELY. THE DRAFTSMAN, FRANCISCO J RUBI, SHALL NOT BE HELD LIABLE FOR ANY ERRORS. ALL CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE STATE AND LOCAL CODES. DO NOT SCALE DRAWINGS, USE ONLY THEPRINTED DIMENSIONS. VERIFY WITH THE WINDOW MANUFACTURER ALL WINDOWS SIZES AND APPLICABLE EGRESS REQUIREMENTS. ALL DIMENSIONS ARE TAKEN FROM/TO ROUGH STUDS OF A DIMENSION OF EITHER 5 ½” (2X6 STUDS), 3 ½” (2X4 STUDS), OR TO THE OUTSIDE OF MASONRY. THE CONTRACTOR SHALLVERIFY ALL MECHANICAL AND ELECTRICAL REQUIREMENTS AND CLEARANCE. CONTRACTOR SHALL VERIFY ALL FLOOR AND ROOF BEARING LOCATIONS. CONTRACTOR SHALL VERIFY ALL BEAM AND HEADER SIZES FOR CODE COMPLIANCE. CITY STAMP
FOR CITY USED
R E N DER IN G FO R I L LUST RAT I O N O N LYRENDERING FO R IL LUST RAT IO N O N LY
RE N D E RIN G FO R IL LUST RATI O N ON LYRENDERING FO R I L LUST R AT I ON O N LY
1ST F LOO R1ST FLOO R
FAJdraftingsolutions
5234 RINEHART AVE
INDIANAPOLIS, INDIANA, 46241
(317) 737-0202
(317) 401-9071
Ow ner
FOR
CONSTRUCTION
THESE DRAWINGS AND ALL COPIES ARE AND SHALL REMAIN THE PROPERTY AND
COPYRIGHT OF THE ARCHITECT AND SHALL NOT BE REPRODUCED IN WHOLE OR IN PART
BY ANY MEANS, MECHANICAL OR ELECTRONIC, WITHOUT EXPRESS WRITTEN
PERMISSION OF THE ARCHITECT. THEY SHALL BE USED ONLY WITH RESPECT TO THIS
PROJECT AND ARE NOT TO BE USED ON ANY OTHER PROJECT OR WORK WITHOUT
PRIOR WRITTEN PERMISSION FROM THE ARCHITECT. COPYRIGHT 2023, BY FAJ
DraftingSolutions L.L.C
ROHRERREMODELING1340 ROHRER RD,CARMEL,INDIANAIssue Date/ProjectStatusPROJECT
NUMBER
D-502
RENDERING
DRAWN BY
CHECKED BY
07222023
F.R
CHECKER
8/1/2023 9:01:51 AMG:/Other computers/My Computer (1)/PROJECT/OPEN PROJECTS/1340 ROHRER RD - G: -- GENERIC_TEMPLATE_627_HANNIBAL_STALTHOUGH EVERY EFFORT HAS BEEN MADE IN PREPARING THESE PLANS AND CHECKING THEM FOR ACCURACY, THE CONTRACTOR MUST CHECK ALL DETAILS AND DIMENSIONS AND BE RESPONSIBLE FOR THE SAME FOR ALL GOVERNING CODES AND BUILDING PRACTICES. THESE DRAWINGS CONFORM TOGENERALLY ACCEPTED BUILDING PRACTICES; HOWEVER, STATE AND LOCAL CODES VARY WIDELY. THE DRAFTSMAN, FRANCISCO J RUBI, SHALL NOT BE HELD LIABLE FOR ANY ERRORS. ALL CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE STATE AND LOCAL CODES. DO NOT SCALE DRAWINGS, USE ONLY THEPRINTED DIMENSIONS. VERIFY WITH THE WINDOW MANUFACTURER ALL WINDOWS SIZES AND APPLICABLE EGRESS REQUIREMENTS. ALL DIMENSIONS ARE TAKEN FROM/TO ROUGH STUDS OF A DIMENSION OF EITHER 5 ½” (2X6 STUDS), 3 ½” (2X4 STUDS), OR TO THE OUTSIDE OF MASONRY. THE CONTRACTOR SHALLVERIFY ALL MECHANICAL AND ELECTRICAL REQUIREMENTS AND CLEARANCE. CONTRACTOR SHALL VERIFY ALL FLOOR AND ROOF BEARING LOCATIONS. CONTRACTOR SHALL VERIFY ALL BEAM AND HEADER SIZES FOR CODE COMPLIANCE. CITY STAMP
FOR CITY USED
R E N DER IN G FO R I L LUST RAT I O N O N LYRENDERING FO R IL LUST RAT IO N O N LY
RE N D E RIN G FO R IL LUST RATI O N ON LYRENDERING FO R I L LUST R AT I ON O N LY
2N D FLOO R2ND F LO OR
FAJdraftingsolutions
5234 RINEHART AVE
INDIANAPOLIS, INDIANA, 46241
(317) 737-0202
(317) 401-9071
Ow ner
FOR
CONSTRUCTION
THESE DRAWINGS AND ALL COPIES ARE AND SHALL REMAIN THE PROPERTY AND
COPYRIGHT OF THE ARCHITECT AND SHALL NOT BE REPRODUCED IN WHOLE OR IN PART
BY ANY MEANS, MECHANICAL OR ELECTRONIC, WITHOUT EXPRESS WRITTEN
PERMISSION OF THE ARCHITECT. THEY SHALL BE USED ONLY WITH RESPECT TO THIS
PROJECT AND ARE NOT TO BE USED ON ANY OTHER PROJECT OR WORK WITHOUT
PRIOR WRITTEN PERMISSION FROM THE ARCHITECT. COPYRIGHT 2023, BY FAJ
DraftingSolutions L.L.C
ROHRERREMODELING1340 ROHRER RD,CARMEL,INDIANAIssue Date/ProjectStatusPROJECT
NUMBER
D-503
RENDERING
DRAWN BY
CHECKED BY
07222023
F.R
CHECKER
8/1/2023 9:01:51 AMG:/Other computers/My Computer (1)/PROJECT/OPEN PROJECTS/1340 ROHRER RD - G: -- GENERIC_TEMPLATE_627_HANNIBAL_STALTHOUGH EVERY EFFORT HAS BEEN MADE IN PREPARING THESE PLANS AND CHECKING THEM FOR ACCURACY, THE CONTRACTOR MUST CHECK ALL DETAILS AND DIMENSIONS AND BE RESPONSIBLE FOR THE SAME FOR ALL GOVERNING CODES AND BUILDING PRACTICES. THESE DRAWINGS CONFORM TOGENERALLY ACCEPTED BUILDING PRACTICES; HOWEVER, STATE AND LOCAL CODES VARY WIDELY. THE DRAFTSMAN, FRANCISCO J RUBI, SHALL NOT BE HELD LIABLE FOR ANY ERRORS. ALL CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE STATE AND LOCAL CODES. DO NOT SCALE DRAWINGS, USE ONLY THEPRINTED DIMENSIONS. VERIFY WITH THE WINDOW MANUFACTURER ALL WINDOWS SIZES AND APPLICABLE EGRESS REQUIREMENTS. ALL DIMENSIONS ARE TAKEN FROM/TO ROUGH STUDS OF A DIMENSION OF EITHER 5 ½” (2X6 STUDS), 3 ½” (2X4 STUDS), OR TO THE OUTSIDE OF MASONRY. THE CONTRACTOR SHALLVERIFY ALL MECHANICAL AND ELECTRICAL REQUIREMENTS AND CLEARANCE. CONTRACTOR SHALL VERIFY ALL FLOOR AND ROOF BEARING LOCATIONS. CONTRACTOR SHALL VERIFY ALL BEAM AND HEADER SIZES FOR CODE COMPLIANCE. CITY STAMP
FOR CITY USED
R E N DER IN G FO R I L LUST RAT I O N O N LYRENDERING FO R IL LUST RAT IO N O N LY
FAJdraftingsolutions
5234 RINEHART AVE
INDIANAPOLIS, INDIANA, 46241
(317) 737-0202
(317) 401-9071
Ow ner
FOR
CONSTRUCTION
THESE DRAWINGS AND ALL COPIES ARE AND SHALL REMAIN THE PROPERTY AND
COPYRIGHT OF THE ARCHITECT AND SHALL NOT BE REPRODUCED IN WHOLE OR IN PART
BY ANY MEANS, MECHANICAL OR ELECTRONIC, WITHOUT EXPRESS WRITTEN
PERMISSION OF THE ARCHITECT. THEY SHALL BE USED ONLY WITH RESPECT TO THIS
PROJECT AND ARE NOT TO BE USED ON ANY OTHER PROJECT OR WORK WITHOUT
PRIOR WRITTEN PERMISSION FROM THE ARCHITECT. COPYRIGHT 2023, BY FAJ
DraftingSolutions L.L.C
ROHRERREMODELING1340 ROHRER RD,CARMEL,INDIANAIssue Date/ProjectStatusPROJECT
NUMBER
D-504
RENDERING
DRAWN BY
CHECKED BY
07222023
F.R
CHECKER
8/1/2023 9:01:51 AMG:/Other computers/My Computer (1)/PROJECT/OPEN PROJECTS/1340 ROHRER RD - G: -- GENERIC_TEMPLATE_627_HANNIBAL_STALTHOUGH EVERY EFFORT HAS BEEN MADE IN PREPARING THESE PLANS AND CHECKING THEM FOR ACCURACY, THE CONTRACTOR MUST CHECK ALL DETAILS AND DIMENSIONS AND BE RESPONSIBLE FOR THE SAME FOR ALL GOVERNING CODES AND BUILDING PRACTICES. THESE DRAWINGS CONFORM TOGENERALLY ACCEPTED BUILDING PRACTICES; HOWEVER, STATE AND LOCAL CODES VARY WIDELY. THE DRAFTSMAN, FRANCISCO J RUBI, SHALL NOT BE HELD LIABLE FOR ANY ERRORS. ALL CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE STATE AND LOCAL CODES. DO NOT SCALE DRAWINGS, USE ONLY THEPRINTED DIMENSIONS. VERIFY WITH THE WINDOW MANUFACTURER ALL WINDOWS SIZES AND APPLICABLE EGRESS REQUIREMENTS. ALL DIMENSIONS ARE TAKEN FROM/TO ROUGH STUDS OF A DIMENSION OF EITHER 5 ½” (2X6 STUDS), 3 ½” (2X4 STUDS), OR TO THE OUTSIDE OF MASONRY. THE CONTRACTOR SHALLVERIFY ALL MECHANICAL AND ELECTRICAL REQUIREMENTS AND CLEARANCE. CONTRACTOR SHALL VERIFY ALL FLOOR AND ROOF BEARING LOCATIONS. CONTRACTOR SHALL VERIFY ALL BEAM AND HEADER SIZES FOR CODE COMPLIANCE. CITY STAMP
FOR CITY USEDRE
NDERING FOR ILLUSTRATION ONLYRENDERING FOR ILLUSTRATION ONLY
FAJdraftingsolutions
5234 RINEHART AVE
INDIANAPOLIS, INDIANA, 46241
(317) 737-0202
(317) 401-9071
Ow ner
FOR
CONSTRUCTION
THESE DRAWINGS AND ALL COPIES ARE AND SHALL REMAIN THE PROPERTY AND
COPYRIGHT OF THE ARCHITECT AND SHALL NOT BE REPRODUCED IN WHOLE OR IN PART
BY ANY MEANS, MECHANICAL OR ELECTRONIC, WITHOUT EXPRESS WRITTEN
PERMISSION OF THE ARCHITECT. THEY SHALL BE USED ONLY WITH RESPECT TO THIS
PROJECT AND ARE NOT TO BE USED ON ANY OTHER PROJECT OR WORK WITHOUT
PRIOR WRITTEN PERMISSION FROM THE ARCHITECT. COPYRIGHT 2023, BY FAJ
DraftingSolutions L.L.C
ROHRERREMODELING1340 ROHRER RD,CARMEL,INDIANAIssue Date/ProjectStatusPROJECT
NUMBER
D-505
RENDERING
DRAWN BY
CHECKED BY
07222023
F.R
CHECKER
8/1/2023 9:01:52 AMG:/Other computers/My Computer (1)/PROJECT/OPEN PROJECTS/1340 ROHRER RD - G: -- GENERIC_TEMPLATE_627_HANNIBAL_STALTHOUGH EVERY EFFORT HAS BEEN MADE IN PREPARING THESE PLANS AND CHECKING THEM FOR ACCURACY, THE CONTRACTOR MUST CHECK ALL DETAILS AND DIMENSIONS AND BE RESPONSIBLE FOR THE SAME FOR ALL GOVERNING CODES AND BUILDING PRACTICES. THESE DRAWINGS CONFORM TOGENERALLY ACCEPTED BUILDING PRACTICES; HOWEVER, STATE AND LOCAL CODES VARY WIDELY. THE DRAFTSMAN, FRANCISCO J RUBI, SHALL NOT BE HELD LIABLE FOR ANY ERRORS. ALL CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE STATE AND LOCAL CODES. DO NOT SCALE DRAWINGS, USE ONLY THEPRINTED DIMENSIONS. VERIFY WITH THE WINDOW MANUFACTURER ALL WINDOWS SIZES AND APPLICABLE EGRESS REQUIREMENTS. ALL DIMENSIONS ARE TAKEN FROM/TO ROUGH STUDS OF A DIMENSION OF EITHER 5 ½” (2X6 STUDS), 3 ½” (2X4 STUDS), OR TO THE OUTSIDE OF MASONRY. THE CONTRACTOR SHALLVERIFY ALL MECHANICAL AND ELECTRICAL REQUIREMENTS AND CLEARANCE. CONTRACTOR SHALL VERIFY ALL FLOOR AND ROOF BEARING LOCATIONS. CONTRACTOR SHALL VERIFY ALL BEAM AND HEADER SIZES FOR CODE COMPLIANCE. CITY STAMP
FOR CITY USED
R E N DERIN G FO R I L LUST RAT I O N O N LYRENDERING FO R IL LUST RAT IO N O N LY