Loading...
HomeMy WebLinkAboutCoram Deo Prints 5.22.23.pdfGeneral Notes Nothing set forth in these Drawings shall release any Contractor from responsibility to provide appropriate quantities, field measurements, dimensional stability, installation, anchorage and coordination with other trades, or waive the Contractor's responsibility to identify and resolve deviations from the requirements of the Contract Documents, or waive the Contractor's responsibility to alert the Architect to errors or omissions contained therein. Each Contractor shall verify in the field all existing applicable conditions and dimensions shown on the Drawings and as pertinent to the intent of these Drawings. Any discrepancy discovered shall be brought to the attention of the Architect prior to the commencement of any Work affected by, or related to, such discrepancy. Each Contractor shall be responsible for all costs associated with, or caused by failure to comply with requirement. Each Contractor shall review in advance all portions of the Work to verify that the Work will not prohibit completion of the Project as intended in these Contract Documents. Any questions shall be promptly referred to the Architect for resolution. Vicinity Map Thoroughfare Map Each Contractor shall refer to the Project Manual for cleaning and disposal requirements. Each Contractor shall be responsible for the protection of all surfaces and finishes at interior and exterior of building. Damaged surfaces and finishes resulting from the performance of the Work shall be repaired at no cost to the Owner by the responsible Contractor to match existing to the satisfaction of the Owner. Each Contractor shall coordinate respective cutting and patching Work with the other Prime Contracts. Each Contractor shall become completely familiar with all aspects of the Work, even those areas designated to be provided by others. This familiarization includes full and complete understanding of the Work described on all Sheets of the Drawings and in all Sections of the Project Manual. Failure by the Contractor to become completely familiar and cognizant of all aspects of the Work shall not relieve the Contractor of the responsibility to provide materials, assemblies, or services indicated in the Contract Documents. 2023-067.POR 05.22.2023 Phase One Renovations Coram Deo Academy Coram Deo Academy Phase One Renovations 525 Congressional Blvd, Carmel, IN 46032 2023-067.POR G-001 SHEET INDEX Number Sheet Name 1 - General G-001 COVER SHEET G-100 FIRE AND LIFE SAFETY PLAN 2 - Site CL101 SITE LAYOUT PLAN 4 - Architectural A-001 ARCHITECTURAL GENERAL NOTES AND ABBREVIATIONS AD1A1 DEMOLITION FLOOR PLAN - UNIT A AD1B1 DEMOLITION FLOOR PLAN - UNIT B AF101 OVERALL FIRST FLOOR PLAN AF1A1 FIRST FLOOR PLAN - UNIT A AF1B1 FIRST FLOOR PLAN - UNIT B AC1A1 FIRST FLOOR REFLECTED CEILING PLAN - UNIT A AC1B1 FIRST FLOOR REFLECTED CEILING PLAN - UNIT B A-600 SCHEDULES & DETAILS 5 - Interiors M H M H M M AR AR AR AR T T T T T T DN EGRESS AREA: 671 SF Classroom CLASSROOM B130 Load: 34 # of Exits: 1 EGRESS AREA: 674 SF Classroom CLASSROOM B126 Load: 31 # of Exits: 1 EGRESS AREA: 630 SF Classroom CLASSROOM B121 Load: 22 # of Exits: 1 559 SF CLASSROOM EGRESS AREA: 543 SF Classroom CLASSROOM B127 Load: 27 # of Exits: 1 EGRESS AREA: 525 SF Classroom CLASSROOM B145 Load: 26 # of Exits: 1 449 SF CLASSROOM EGRESS AREA: 538 SF Classroom CLASSROOM B137 Load: 27 Abbreviations A/E ADA ARCHITECT/ENGINEER AMERICANS WITH DISABILITIES ACT ADD ADJ ADDENDUM ADJACENT ADMIN AFF ADMINISTRATION ABOVE FINISHED FLOOR ALUM APPROX ALUMINUM APPROXIMATE APC APT ACOUSTICAL PANEL CEILING APARTMENT ARCH ASSN ARCHITECT ASSOCIATION ASTM A/V AMERICAN SOCIETY FOR TESTING AND MATERIALS AUDIO/VISUAL AVG AWI AVERAGE ARCHITECTURAL WOODWORKING INSTITUTE BD BITUM BOARD BITUMINOUS BLDG BLKHD BUILDING BOT BSMT BOTTOM BASEMENT BULKHEAD CAB CB CABINET CHALK BOARD CD CD CONSTRUCTION DOCUMENTS CONTRACT DOCUMENTS CIP CJ CAST-IN-PLACE CONTROL JOINT CL CLG CENTER LINE 5 6 7 8 4 9 A 2 1 B C D E 10 11 12 H J K L F G A5 E.P E.P 06 02 02 02 04 03 04 01 05 05 05 09 09 08 08 01 05 05 01 05 01 09 05 01 01 01 09 09 09 08 08 01 01 01 01 09 08 01 09 09 DN 5 A 1 2 B C D G A1 A2 A3 A4 A5 E.P 02 02 02 02 02 02 02 02 07 10 10 09 09 09 08 08 08 05 05 05 05 01 05 01 01 01 09 09 09 09 08 08 08 08 01 01 01 01 01 09 08 01 05 01 09 08 09 08 09 08 01 01 22 22 22 22 01 01 01 05 05 08 01 08 08 09 01 01 01 01 09 08 09 09 08 08 22 M H M D D CR H M M AR AR AR AR T T T T T T DN OVERALL PLANS ARE FOR REFERENCE ONLY; REFERENCE UNIT PLANS FOR FULL SCOPE OF WORK SHADED REGION INDICATES AREAS WITH NO SCOPE OF WORK CLASSROOM B115 CHAPEL B111 CAFETERIA B111A COMMONS B141 CLASSROOM B145 STORAGE B146A STORAGE B146 CLASSROOM B127 LIBRARY B135 IDF B129 CLASSROOM B137 PRE-K B132 KITCHENETTE B133 CLASSROOM B130 CORRIDOR B001 CLASSROOM B126 CLASSROOM B121 CLASSROOM A116 CLASSROOM A120 OFFICE A119 5 6 7 8 4 9 A 2 1 B C D E E 10 11 12 H J K L F G A5 E.P S4-C A110.1 F ETR HM1 : HM-001 2=F1 A110.2 F ETR HM1 : HM-001 2=F1 A110.3 G ETR SF-125A Exist : SF-125A=EXIST GYM A110 CLASSROOM B117 CLASSROOM B115 RR A110C CORRIDOR A002 STORAGE A110A CLASSROOM A116 CLASSROOM A120 SCIENCE LAB A121 CLASSROOM A118 OFFICE A119 5D AF1A1 01 04 CAFETERIA B111A 08 DN 5 A 1 2 B C D G A1 A2 A3 A4 A5 E.P PRE-K B132 OFFICE B131 CLASSROOM B130 CLASSROOM B126 CLASSROOM B121 CLASSROOM B127 LIBRARY B135 COMMONS B141 CLASSROOM B145 CLASSROOM B138 CLASSROOM B137 CHAPEL B111 02 03 03 01 01 01 S4iC B130 F ETR HM-112A Exist : HM-112D (9'-2")=F2 B126 F ETR HM-112A Exist : HM-112D (9'-2")=F2 CAFETERIA B111A 07 CHAPEL B111 CLASSROOM B120 CLASSROOM B110 STORAGE B112 PRACTICE ROOM B113 OFFICE V H H V TV H V V V S D S D S D A. All ceilings are at 10'-0" AFF, unless noted otherwise. B. All bulkheads are at 9'-10" AFF, unless noted otherwise. C. All grids are centered in rooms, unless noted otherwise. D. All exposed ductwork, piping etc. shall be painted. Color selected by Architect. E. Locate sprinkler heads in center of ceiling panel - where applicable. F. Bulkheads to receive paint, P-1, in its entirety unless otherwise noted. General Refl. Ceiling Plan Notes 6 6 7 7 8 8 5 5 4 4 9 9 A A 2 2 1 1 B B C C D D E E 10 10 11 11 12 12 H H J J K K L V V V S F H M S F H V V V V H H V V V H M V O1 O1 O1 O1 V A. All ceilings are at 10'-0" AFF, unless noted otherwise. B. All bulkheads are at 9'-10" AFF, unless noted otherwise. C. All grids are centered in rooms, unless noted otherwise. D. All exposed ductwork, piping etc. shall be painted. Color selected by Architect. E. Locate sprinkler heads in center of ceiling panel - where applicable. F. Bulkheads to receive paint, P-1, in its entirety unless otherwise noted. General Refl. Ceiling Plan Notes REFLECTED CEILING PLAN LEGEND APC-1 2' X 2' Acoustical Panel Ceiling (09 51 13) GWB 5/8" GWB on Grid Suspension System (09 22 16) Walls to Deck Light Fixture (Reference E-Series Dwgs) Return Air (Reference M-Series Dwgs) Supply Air (Reference M-Series Dwgs) Exit Light (Reference E-Series Dwgs) Recessed Light Fixture Suspended Fixture in Areas with Exposed Ceilings (Reference E-Series Dwgs) S SOUND SYSTEM SPEAKER (REFERENCE E-SERIES/T- SERIES DWGS) F1 2" 2" SEE SCHED. 2" SEE SCHED. F-3 F-2 9' - 2" V.I.F. 2" TYP. SEE SCHED. SEE SCHED. 7' - 6" V.I.F. 3' - 3" V.I.F. 1" TYP. F-4 7' - 6" V.I.F. 6' - 0" V.I.F. 1" TYP. 4" 4" SEE SCHED. SEE SCHED. G F SEE SCHED. SEE SCHED. 6" 6" 3' - 6" GENERAL NOTES A. This Door Schedule(s) is furnished for whatever assistance it may afford the Contractor. Do not consider it as entirely inclusive. Carefully examine the Drawings (especially the Floor Plans) and the Specifications to determine the extent of door and frame quantities required (including interior borrowed lite or sidelite openings). Should any particular door, frame, or interior borrowed lite or sidelite shown on the Drawings be inadvertently omitted from this Schedule, supply same as required for similar openings. B. The "QTY" column designates the number of leaves in the opening. The "Door Width" column designates the total width of all leaves. In multiple leaf conditions, the leaves shall equally divide the "Door Width" unless noted otherwise; however, the active leaf shall not be less than 3'-0" wide. C. Verify locksets with the Owner during submittals. ABBREVIATIONS AL Aluminum HM Hollow Metal ST Steel WD Wood TG Tempered Glazing IG Insulated Glazing LG Laminated Glazing FG Frosted Glazing SP Spandrel Panel DOOR & FRAME SCHEDULE NOTES See Door Schedule 1. New door in existing frame. Field verify dimensions prior to fabrication. Provide new continuous aluminum hinge confirming to ANSI/BHMA A156.26, Grade 1. provide hinges 1" shorter than nominal height of door with symmetrical hole pattern. Glazing type and finish to match existing adjacent glazing. 2. Salvaged existing door and frame. Field verify size and type. 3. All hardware is Existing to Reamin unless noted otherwise. 09 29 00.B7 - INT GWB, 5/8" TYPE X 09 22 16.C6 - INT STEEL STUD FRAMING, 3-5/8" @ 16" O.C. EXISTING CEILING TO REMAIN. TS A. B. C. D. E. F. G. H. I. J. K. INTERIOR GENERAL NOTES FINISHES PRIOR TO START & FINAL COMPLETION OF WORK • Where existing finishes are to remain outside scope of work, patch & repair any area damaged or effected by renovation, to return to like new condition, matching adjacent finishes. This includes, but is not limited to doors & associated hardware, door frames, wall finishes, wall base, floor finish including floor transitions & thresholds, etc. It is the responsibility of the contractor to verify conditions in field prior to start & completion of work. Interior Painting/Wallcovering • Existing wall conditions that were not specifically noted to be patched and repaired, but are designated to receive new finishes, are to be repaired prior to new finishes being applied. It is the Contractors responsibility to confirm conditions in field prior to start of work. • Vinyl Wall Base over gyp. - Prior to removal of existing vinyl wall base, score wall above top of base to minimize damage to drywall. Reference architectural ceilings plans for ceiling heights and bulkhead color designations. Paint all bulkheads HP-1 or P-1 (neutral to match existing) unless specifically noted otherwise. Bulkheads that are flush with walls provide color to match adjacent wall color. Paint interior hollow metal door frames high performance (HP) paint to match existing. Paint all exposed conduit, piping, and associated assemblies to match adjacent paint finish. Applies to all new & existing to remain in areas of renovation or new construction. Paint general walls HP-1 or P-1 (Neutral to match existing) unless specifically noted otherwise, only in areas that have been affected by demolition. Wall Base 1. Install vinyl wall base on top of rigid wall protection. Provide caulk joint at floor level, typ. 2. Provide vinyl wall base around all casework unless specicially noted otherwise 3. Provide new vinyl wall base to match existing on new wall construction. Where floor finish transitions between rooms, align transition centered with threshold of door unless noted otherwise. 1. LVT to carpet does not require transition strip, products will abutt at same height. Science classroom: epoxy top student tables, stools, mobile teacher demo station, and chemical storage units are included in this contract. Appliances and vending equipment are not provided in this contract. Visual display boards (marker and tack boards) to be mounted at 3' - 0" A.F.F. I-201 2E 2C I-201 2A 2D GYM A110 WALL:ETR FLOOR:ETR BASE:ETR/VWB-1 CLASSROOM B117 CLASSROOM B115 RR TS TS TS TS DN PRE-K B132 WALL:ETR FLOOR:ETR BASE:ETR OFFICE B131 CLASSROOM B130 WALL:ETR FLOOR:ETR BASE:ETR CLASSROOM B126 WALL:ETR FLOOR:ETR BASE:ETR CORRIDOR B001 CLASSROOM B121 WALL:ETR FLOOR:ETR BASE:ETR CLASSROOM B127 WALL:ETR FLOOR:ETR BASE:ETR LIBRARY B135 WALL:ETR/P-1 FLOOR:CPT-1 BASE:VWB-1 COMMONS B141 WALL:P-1 FLOOR:CPT-1 BASE:VWB-1 CLASSROOM B145 WALL:ETR FLOOR:ETR BASE:ETR CLASSROOM B138 CLASSROOM B137 CHAPEL B111 02 03 03 01 01 01 2' - 6" SINK 2' - 6" 3' - 0" SINK 2' - 6" 3' - 0" SINK 3' - 0" 3' - 0" 1' - 6" 3' - 6" 8' - 0" 12" D. 2 DR GLASS DR WALL CABINET, TYP. RECESSED EYEWASH STATION TO BE PROVIDED IN CONTRACT. SEE "P" SERIES DRWGS FOR DETAILS. MODEL SHOWN AS PLACEHOLDER ONLY. FUME HOOD TO BE PROVIDED IN CONTRACT. SEE "M" SERIES DRWGS FOR DETAILS. 31" D. EPOXY COUNTER- TOP. 6" CHASE DEPTH BEHIND CABINETS IS TO BE MAINTAINED. 24" D. 2 DR. BASE CABINET, TYP. 24" D. 2 DR SINK BASE, TYP. FILL 2' - 6" 2' - 6" 3' - 0" 2' - 6" 3' - 0" 2' - 6" 3' - 0" 2' - 6" 3' - 7" 30" BY 36" EPOXY PEG DRYING RACK. 14" D. +/- CORNER CABINET W/ADJ. SHELVES. 24" D. 4 DWR BASE CABINET. WALL TO RECEIVE RIGID WALL PROTECTION. BASIS- OF-DESIGN: ACROVYN 4' x 8' SHEETS DIRECT-GLUED TO WALL. COLOR: DRIFTWOOD #262 CLEAR 4' - 0" 15" MIN. FILL FILL REF. SPECIFICATION AND CONFIGURATION SHEET FOR FUME HOOD DETAILS AND STORAGE CABINETS BELOW. FILL 2' - 7" 1' - 9" BASIS-OF-DESIGN: JUSTRITE, 22 GAL, SURE-GRIP, UNDER COUNTER, MODEL# 892322 *ALL CASEWORK BASIS-OF-DESIGN: DIVERSIFIED WOODCRAFTS PLASTIC LAMINATE LABORATORY CASEWORK. WALL TO RECEIVE VINYL WALL BASE, VWB-1, TYP. SINK 3' - 0" 2' - 6" SINK 3' - 0" 2' - 6" 12" D. 2 DR GLASS DR WALL CABINET, TYP. 31" D. EPOXY ABBREVIATIONS EDR EQUIVALENT DIRECT RADIATION SA GALV GALVANIZED STP HWCF HEATING HOT WATER CHEMICAL FEED HHWR HWP HEATING HOT WATER RETURN HEATING HOT WATER PUMP STS STRUCT HPWS HPWP HSPF HRP HR HE HD HORIZ HP HPWR HEAT RECOVERY PUMP HEAT PUMP WATER SUPPLY HEAT PUMP WATER PUMP HOUR HEATING SEASONAL PERFORMANCE FACTOR HEAT PUMP WATER RETURN HEAT EXCHANGER HORSEPOWER/HEAT PUMP HORIZONTAL HEAD (FT.) GR GRV GS H GIV GC GPM GPH GLYCOL RETURN GLYCOL SUPPLY HUMIDITY/HUMIDIFIER GRAVITY RELIEF VENTILATOR GENERAL CONTRACTOR GALLONS PER MINUTE GALLONS PER HOUR GRAVITY INTAKE VENTILATOR STD ST SS SPEC SRV SHT SD SG SHR SECT SF SCC T 5 6 7 8 9 C D E 10 11 12 H J K L F G E.P 3 SD24-12 SD24-12 SD24-12 SD24-12 EC24/12 EC24/24 EC24/12 SD24-8 SD24-8 SD24-8 EC24/12 1 1 1 1 1 1 1 1 EC24/12 1 1 1 1 18"x12" SA 12"x8" SA 1 A. B. C. DARK DASHED LINES INDICATE EXISTING MECHANICAL EQUIPMENT, DUCTWORK, PIPING, AND/OR MECHANICAL ACCESSORIES DEMOLISHED COMPLETE. CONTRACTOR TO FIELD VERIFY ACTUAL EXISTING CONDITIONS PRIOR TO BIDDING AND DEMOLITION. CONTRACTOR TO INCLUDE ALL COST TO REMOVE ITEMS MADE OBSOLETE DUE TO NEW HVAC WORK. CONTRACTOR GIVES OWNER FIRST RIGHTS OF REFUSAL ON ANY EXISTING EQUIPMENT THE OWNER MAY WANT TO KEEP. IF OWNER DECIDES SAID ITEM IS TO BE REMOVED, THEN CONTRACTOR IS TO REMOVE FROM PROJECT SITE AS REQUIRED. LIGHT SOLID LINES INDICATE EXISTING MECHANICAL EQUIPMENT, DUCTWORK, PIPING, AND/OR MECHANICAL ACCESSORIES TO REMAIN AS-IS. CONTRACTOR TO FIELD VERIFY ACTUAL EXISTING CONDITIONS PRIOR TO DEMOLITION AND BIDDING. GENERAL DEMOLITION NOTES N 6 5 4 3 2 1 A T T T T T 5 A 1 2 B C D G A1 A2 A3 A4 A5 E.P 3 5 6 1 6 3 2 2 2 SD24-10 SD24-10 SD24-10 SD24-10 SD24-10 SD24-10 SD24-10 SD24-10 SD24-10 SD24-10 SD24-10 SD24-10 SD24-10 2 2 2 2 2 2 2 2 2 2 2 2 EC24/24 2 SD24-12 SD24-12 EC24/24 5 EC24/12 2 SD24-12 SD24-12 3 2 2 SD24-10 SD24-10 A. B. C. DARK DASHED LINES INDICATE EXISTING MECHANICAL EQUIPMENT, DUCTWORK, PIPING, AND/OR MECHANICAL ACCESSORIES DEMOLISHED COMPLETE. CONTRACTOR TO FIELD VERIFY ACTUAL EXISTING CONDITIONS PRIOR TO BIDDING AND DEMOLITION. CONTRACTOR TO INCLUDE ALL COST TO REMOVE ITEMS MADE OBSOLETE DUE TO NEW HVAC WORK. CONTRACTOR GIVES OWNER FIRST RIGHTS OF REFUSAL ON ANY EXISTING EQUIPMENT THE OWNER MAY WANT TO KEEP. IF OWNER DECIDES SAID ITEM IS TO BE REMOVED, THEN CONTRACTOR IS TO REMOVE FROM PROJECT SITE AS REQUIRED. LIGHT SOLID LINES INDICATE EXISTING MECHANICAL EQUIPMENT, DUCTWORK, PIPING, AND/OR MECHANICAL ACCESSORIES TO REMAIN AS-IS. CONTRACTOR TO FIELD VERIFY ACTUAL EXISTING CONDITIONS PRIOR TO DEMOLITION AND BIDDING. GENERAL DEMOLITION NOTES N T 5 6 7 8 9 C D E 10 11 12 H J K L F G E.P OFFICE A115 OFFICE A114 CLASSROOM A116 CLASSROOM A113 STORAGE A111 CLASSROOM A120 OFFICE A102 WOMENS RR A108 UNOCCUPIED A124 MENS RR A109 OFFICE B106 OFFICE B105 WOMENS RR B104 STORAGE B115C RISER RM A108A STORAGE A103A JANITOR A107 OFFICE A105 OFFICE A103 PARENT ROOM B100 SCIENCE LAB A121 UNOCCUPIED A122 T T T T T 5 A 1 2 B C D G A1 A2 A3 A4 A5 E.P STORAGE B129B IDF B129 STORAGE B129A KITCHEN B128 CLASSROOM LIBRARY B127 B135 STORAGE B112 CLASSROOM B121 CLASSROOM B120 STORAGE B142 STORAGE B143 STORAGE B144 STORAGE B140 STORAGE B139 RR B134 WOMENS RR B148 VESTIBULE B111B OFFICE B147 OFFICE B108 COPIER B109 PARENT ROOM B100 MENS RR B149 PLUMBING B123 OFFICE KITCHENETTE B124 B133 5 6 7 8 9 C D E 10 11 12 H J K L F G E.P EF-A1 5 A 1 2 B C D G A1 A2 A3 A4 A5 E.P A. B. C. DARK LINES INDICATE NEW WORK. LIGHT SOLID LINES INDICATE EXISTING MECHANICAL EQUIPMENT, DUCTWORK, PIPING, AND/OR MECHANICAL ACCESSORIES TO REMAIN AS-IS. CONTRACTOR TO FIELD VERIFY ACTUAL EXISTING CONDITIONS PRIOR TO BIDDING. ALL ROOF WORK SHALL BE IN ACCORDANCE WITH OWNER ’S EXISTING ROOF WARRANTY. WARRANTY SHALL BE MAINTAINED. GENERAL ROOF NOTES N 6 5 4 3 2 1 A B C D E 6 5 4 3 2 1 A B C D E Project No. Project Date Produced These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect. KEY PLAN B A 5/22/2023 12:48:49 PM C:\_RevitLocal\2023-067.POR_Bldg001_M_2023\2023-067.POR_Bldg001_M_2023_tkennedy.rvt ELEC HTG RETURN GRILLE AND TRANSFER DUCTWORK. REFER TO HVAC FLOOR PLANS AND SCHEDULES FOR DUCT AND GRILLE SIZES. 1" INTERNALLY LINED 22 GAUGE SHEET METAL DUCT. DUCT LINING TO BE BLACK. 8" CLEAR (MIN.) UNLESS OTHERWISE NOTED ON DRAWINGS. 8" MIN. CEILING 3" 4'-0" MIN. LENGTH NOTE: MAINTAIN ALL DIMENSIONS WHERE POSSIBLE EXCEPT WHEN LIMITED BY STRUCTURE, FIR PROTECTION PIPING, ELECTRICAL CONDUIT, ETC. EXHAUST DUCT. REFER TO HVAC FLOOR PLANS FOR EXACT SIZE AND ROUTING ROOF STRUCTURE, REFER TO STRUCTURAL DRAWINGS FOR TYPE ROOF CONSTRUCTION, SEE ARCHITECTURAL DRAWINGS FOR TYPE PRE-FABRICATED INSULATED ROOF CURB SECURE FAN TO ROOF CURB AS REQUIRED WITH A MINIMUM OF TWO (2) FASTENERS PER SIDE MOTOR ALUMINUM HOUSING FAN 1. NOTE: ALL POWER ROOF VENTILATORS SHALL BE MOUNTED LEVEL. PROVIDE SLOPED CURBS AND SHIMS AS REQUIRED FOR SLOPED ROOFS. REFER TO ARCHITECTURAL DRAWINGS FOR PITCH OF ROOF. ROCK WOOL ROCK WOOL EGGCRATE TYPE CEILING RETURN GRILLE 1" BLACK RIGID INSULATION BOARD WASHER WITH BLACK NEOPRENE PAD ON UNDERSIDE WIRE SUPPORT ATTACHED TO STRUCTURE 8" MIN. SIDES 12" ALL FOUR AIR FLOW LOW PRESSURE SUPPLY BRANCH DUCT 45°/90° ENTRY FITTING WITH MANUAL VOLUME DAMPER LIKE FLEXMASTER MODEL STO AT AV AW AIR CW GAS GW HW ABANDONED ACID-RESISTANT VENT ABANDONED ACID-RESISTANT WASTE ABANDONED AIR ABANDONED COLD WATER ABANDONED GAS ABANDONED GREASE WASTE ABANDONED HOT WATER ABANDONED PIPING SYSTEMS HWR ABANDONED HOT WATER RETURN FP ABANDONED FIRE PROTECTION N2 ABANDONED NITROGEN ST ABANDONED STORM VAC ABANDONED VACUUM V ABANDONED VENT W ABANDONED WASTE GALV GALVANIZED STP HWR HOT WATER RETURN STS, STR STRUCT HWCP HR HO HD HORIZ HOUR HORIZONTAL HEAD (FT.) HUB OUTLET HB GC GPM GT GPH HOSE BIB GENERAL CONTRACTOR GALLONS PER MINUTE GALLONS PER HOUR GREASE TRAP STD ST SSK SSD SS SPEC SPG SHT SK SH SECT SF SB SCW CR CR T 1. EXISTING PIPE ROUTING, AS SHOWN ON DRAWINGS, IS BASED UPON RECORD DOCUMENTS AND FIELD SURVEYS. ACTUAL ROUTE OF CONCEALED PIPING MAY VARY. CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY PIPE ROUTING PRIOR TO SAW CUTTING OF FLOOR SLABS. 2. CONTRACTOR SHALL JET AND THOROUGHLY FLUSH EXISTING SANITARY SEWERS WHERE DOCUMENTS CALL FOR NEW WASTE PIPE CONNECTIONS. 3. ALL UNDERGROUND SANITARY OR STORM PIPING SHOWN TO BE ABANDONED IN PLACE SHALL BE CAPPED AND FILLED WITH FLOWABLE FILL. 4. WHERE PLUMBING FIXTURE ROUGH-IN PIPING IS SHOWN TO BE ABANDONED IN WALLS OR BELOW FLOOR SLAB, ROUGH-INS SHALL BE REMOVED TO A POINT BEYOND THE FINISHED SURFACE AND CAPPED. PATCH SURFACE TO MATCH EXISTING FINISH. 5. IN AREAS WHERE A FULL REMODEL IS INDICATED ON THE DRAWINGS, CONTRACTOR SHALL REMOVE ALL OVERHEAD PIPING AND HANGERS COMPLETE UNLESS OTHERWISE INDICATED. 6. WHERE SANITARY OR ACID VENT THROUGH ROOF IS SHOWN TO BE ABANDONED IN PLACE, CONTRACTOR SHALL PERMANENTLY CAP PIPE ABOVE AND BELOW ROOF FOR A WATER TIGHT SEAL. PLUMBING RENOVATION NOTES 6 6 7 7 8 8 5 5 9 C D E E 10 10 11 11 12 12 H H J K L L F G G E.P E.P 1 OFFICE A115 OFFICE A114 CLASSROOM A116 CLASSROOM A113 STORAGE T T T T T T 1. EXISTING PIPE ROUTING, AS SHOWN ON DRAWINGS, IS BASED UPON RECORD DOCUMENTS AND FIELD SURVEYS. ACTUAL ROUTE OF CONCEALED PIPING MAY VARY. CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY PIPE ROUTING PRIOR TO SAW CUTTING OF FLOOR SLABS. 2. CONTRACTOR SHALL JET AND THOROUGHLY FLUSH EXISTING SANITARY SEWERS WHERE DOCUMENTS CALL FOR NEW WASTE PIPE CONNECTIONS. 3. ALL UNDERGROUND SANITARY OR STORM PIPING SHOWN TO BE ABANDONED IN PLACE SHALL BE CAPPED AND FILLED WITH FLOWABLE FILL. 4. WHERE PLUMBING FIXTURE ROUGH-IN PIPING IS SHOWN TO BE ABANDONED IN WALLS OR BELOW FLOOR SLAB, ROUGH-INS SHALL BE REMOVED TO A POINT BEYOND THE FINISHED SURFACE AND CAPPED. PATCH SURFACE TO MATCH EXISTING FINISH. 5. IN AREAS WHERE A FULL REMODEL IS INDICATED ON THE DRAWINGS, CONTRACTOR SHALL REMOVE ALL OVERHEAD PIPING AND HANGERS COMPLETE UNLESS OTHERWISE INDICATED. 6. WHERE SANITARY OR ACID VENT THROUGH ROOF IS SHOWN TO BE ABANDONED IN PLACE, CONTRACTOR SHALL PERMANENTLY CAP PIPE ABOVE AND BELOW ROOF FOR A WATER TIGHT SEAL. PLUMBING RENOVATION NOTES 1. SPRINKLER SCHEDULE: ROOMS WITHOUT CEILINGS: UPRIGHT SPRINKLERS ROOMS WITH CEILINGS: SEMI-RECESSED SPRINKLER HEADS WALL MOUNTING: SIDEWALL SPRINKLER HEADS SUBJECT TO FREEZING: DRY PENDANT SPRINKLER HEADS 2. ALL SPRINKLER COVERAGE SHALL COMPLY WITH MINIMUM STANDARDS AS ESTABLISHED BY NFPA 13, INCLUDING OFFICE SPACES. 3. WHERE APPLICABLE, INCOMING FIRE PROTECTION WATER SERVICE AND FIRE DEPARTMENT CONNECTION MAIN FROM 5'-0" OUTSIDE OF BUILDING TO FLANGED CONNECTION 12" ABOVE FLOOR OR FROM WALL SHALL BE PROVIDED BY DIVISION 22. 4. WHERE MAIN ELECTRIC ROOMS HAVE A 2-HOUR RATING, DO NOT INSTALL SPRINKLER COVERAGE. 5. DO NOT ROUTE SPRINKLER PIPING OVER ANY TELEDATA, IDF, MDF OR SIMILAR ROOM. PROVIDE SIDEWALL SPRINKLER COVERAGE FOR THE SPACE WITH HEAD LOCATED ABOVE DOOR WHEREVER POSSIBLE. 6. DO NOT ROUTE SPRINKLER PIPING OVER ANY ELECTRICAL ROOM. PROVIDE SIDEWALL SPRINKLER COVERAGE FOR THE SPACE WITH HEAD LOCATED ABOVE DOOR WHEREVER POSSIBLE. FIRE PROTECTION GENERAL NOTES 6 6 7 7 8 8 5 5 4 9 A A 2 2 1 1. EXISTING PIPE ROUTING, AS SHOWN ON DRAWINGS, IS BASED UPON RECORD DOCUMENTS AND FIELD SURVEYS. ACTUAL ROUTE OF CONCEALED PIPING MAY VARY. CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY PIPE ROUTING PRIOR TO SAW CUTTING OF FLOOR SLABS. 2. CONTRACTOR SHALL JET AND THOROUGHLY FLUSH EXISTING SANITARY SEWERS WHERE DOCUMENTS CALL FOR NEW WASTE PIPE CONNECTIONS. 3. ALL UNDERGROUND SANITARY OR STORM PIPING SHOWN TO BE ABANDONED IN PLACE SHALL BE CAPPED AND FILLED WITH FLOWABLE FILL. 4. WHERE PLUMBING FIXTURE ROUGH-IN PIPING IS SHOWN TO BE ABANDONED IN WALLS OR BELOW FLOOR SLAB, ROUGH-INS SHALL BE REMOVED TO A POINT BEYOND THE FINISHED SURFACE AND CAPPED. PATCH SURFACE TO MATCH EXISTING FINISH. 5. IN AREAS WHERE A FULL REMODEL IS INDICATED ON THE DRAWINGS, CONTRACTOR SHALL REMOVE ALL OVERHEAD PIPING AND HANGERS COMPLETE UNLESS OTHERWISE INDICATED. 6. WHERE SANITARY OR ACID VENT THROUGH ROOF IS SHOWN TO BE ABANDONED IN PLACE, CONTRACTOR SHALL PERMANENTLY CAP PIPE ABOVE AND BELOW ROOF FOR A WATER TIGHT SEAL. PLUMBING RENOVATION NOTES 6 6 7 7 8 8 5 5 9 C D E E 10 10 11 11 12 12 H H J J K L L F G E.P E.P OFFICE A104 CORRIDOR A001 OFFICE A105 CORRIDOR A002 BREAK ROOM A106 STORAGE A106A T 6 6 7 7 8 8 5 5 9 C D D E E 10 10 11 11 12 12 H H J J K L F F G E.P E.P EX. 1/2" CW 1 2 CLASSROOM B115 CORRIDOR B001 PARENT ROOM B100 OFFICE B107 OFFICE B106 OFFICE B105 RR A110C STORAGE B115C STORAGE B115B COPIER B109 LOBBY A100 CORRIDOR B001 MENS RR B103 WOMENS RR T 1. EXISTING PIPE ROUTING, AS SHOWN ON DRAWINGS, IS BASED UPON RECORD DOCUMENTS AND FIELD SURVEYS. ACTUAL ROUTE OF CONCEALED PIPING MAY VARY. CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY PIPE ROUTING PRIOR TO SAW CUTTING OF FLOOR SLABS. 2. CONTRACTOR SHALL JET AND THOROUGHLY FLUSH EXISTING SANITARY SEWERS WHERE DOCUMENTS CALL FOR NEW WASTE PIPE CONNECTIONS. 3. ALL UNDERGROUND SANITARY OR STORM PIPING SHOWN TO BE ABANDONED IN PLACE SHALL BE CAPPED AND FILLED WITH FLOWABLE FILL. 4. WHERE PLUMBING FIXTURE ROUGH-IN PIPING IS SHOWN TO BE ABANDONED IN WALLS OR BELOW FLOOR SLAB, ROUGH-INS SHALL BE REMOVED TO A POINT BEYOND THE FINISHED SURFACE AND CAPPED. PATCH SURFACE TO MATCH EXISTING FINISH. 5. IN AREAS WHERE A FULL REMODEL IS INDICATED ON THE DRAWINGS, CONTRACTOR SHALL REMOVE ALL OVERHEAD PIPING AND HANGERS COMPLETE UNLESS OTHERWISE INDICATED. 6. WHERE SANITARY OR ACID VENT THROUGH ROOF IS SHOWN TO BE ABANDONED IN PLACE, CONTRACTOR SHALL PERMANENTLY CAP PIPE ABOVE AND BELOW ROOF FOR A WATER TIGHT SEAL. PLUMBING RENOVATION NOTES 6 6 7 7 8 8 5 5 9 C D E E 10 10 11 11 12 12 H H J K L F G E.P E.P 3 FCO 1 1/2" TW 1 1/2" TW 1 1/2" TW 1 1/2" TW TMV-1 1 1/4" CW 1 1/4" HW 1/2" G (6 in-wc) 1/2" G (6 in-wc) 1/2" CW 1/2" HW 1. EXISTING PIPE ROUTING, AS SHOWN ON DRAWINGS, IS BASED UPON RECORD DOCUMENTS AND FIELD SURVEYS. ACTUAL ROUTE OF CONCEALED PIPING MAY VARY. CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY PIPE ROUTING PRIOR TO SAW CUTTING OF FLOOR SLABS. 2. CONTRACTOR SHALL JET AND THOROUGHLY FLUSH EXISTING SANITARY SEWERS WHERE DOCUMENTS CALL FOR NEW WASTE PIPE CONNECTIONS. 3. ALL UNDERGROUND SANITARY OR STORM PIPING SHOWN TO BE ABANDONED IN PLACE SHALL BE CAPPED AND FILLED WITH FLOWABLE FILL. 4. WHERE PLUMBING FIXTURE ROUGH-IN PIPING IS SHOWN TO BE ABANDONED IN WALLS OR BELOW FLOOR SLAB, ROUGH-INS SHALL BE REMOVED TO A POINT BEYOND THE FINISHED SURFACE AND CAPPED. PATCH SURFACE TO MATCH EXISTING FINISH. 5. IN AREAS WHERE A FULL REMODEL IS INDICATED ON THE DRAWINGS, CONTRACTOR SHALL REMOVE ALL OVERHEAD PIPING AND HANGERS COMPLETE UNLESS OTHERWISE INDICATED. 6. WHERE SANITARY OR ACID VENT THROUGH ROOF IS SHOWN TO BE ABANDONED IN PLACE, CONTRACTOR SHALL PERMANENTLY CAP PIPE ABOVE AND BELOW ROOF FOR A WATER TIGHT SEAL. PLUMBING RENOVATION NOTES 6 6 7 7 8 8 5 5 3" VTR N 6 5 4 3 2 1 A B C D E 6 5 4 3 2 1 A B C D E Project No. Project Date Produced These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect. KEY PLAN B A 5/22/2023 6:04:42 PM C:\_RevitLocal\2023-067.POR_Bldg001_P_2023\2023-067.POR_Bldg001_P_2023_jbaughman.rvt 2023-067.POR 05.22.2023 ROOF LEVEL PLUMBING PLAN - ALTERNATE PR101 Designer JJB 1. EXISTING PIPE ROUTING, AS SHOWN ON DRAWINGS, IS BASED UPON RECORD DOCUMENTS AND FIELD SURVEYS. ACTUAL ROUTE OF CONCEALED PIPING MAY VARY. CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY PIPE ROUTING PRIOR TO SAW CUTTING OF FLOOR SLABS. 2. CONTRACTOR SHALL JET AND THOROUGHLY FLUSH EXISTING SANITARY SEWERS WHERE DOCUMENTS CALL FOR NEW WASTE PIPE CONNECTIONS. 3. ALL UNDERGROUND SANITARY OR STORM PIPING SHOWN TO BE ABANDONED IN PLACE SHALL BE CAPPED AND FILLED WITH FLOWABLE FILL. 4. WHERE PLUMBING FIXTURE ROUGH-IN PIPING IS SHOWN TO BE ABANDONED IN WALLS OR BELOW FLOOR SLAB, ROUGH-INS SHALL BE REMOVED TO A POINT BEYOND THE FINISHED SURFACE AND CAPPED. PATCH SURFACE TO MATCH EXISTING FINISH. 5. IN AREAS WHERE A FULL REMODEL IS INDICATED ON THE DRAWINGS, CONTRACTOR SHALL REMOVE ALL OVERHEAD PIPING AND HANGERS COMPLETE UNLESS OTHERWISE INDICATED. 6. WHERE SANITARY OR ACID VENT THROUGH ROOF IS SHOWN TO BE ABANDONED IN PLACE, CONTRACTOR SHALL PERMANENTLY CAP PIPE ABOVE AND BELOW ROOF FOR A WATER TIGHT SEAL. PLUMBING RENOVATION NOTES 6" LONG HARDWOOD BLOCK SHAPED TO PIPE AND HANGER INSULATION PIPE PIPE INSULATION HEAVY DUTY CLEVIS HANGER SUPPORT NUT LOCKING NUT HANGER ROD 14 GUAGE ZINC COATED SHEET STEEL SADDLE, AT LEAST 6" LONG N 6 5 4 3 2 1 A B C D E 6 5 4 3 2 1 A B C D E Project No. Project Date Produced These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect. KEY PLAN B A 5/22/2023 6:04:51 PM C:\_RevitLocal\2023-067.POR_Bldg001_P_2023\2023-067.POR_Bldg001_P_2023_jbaughman.rvt 1. EXISTING PIPE ROUTING, AS SHOWN ON DRAWINGS, IS BASED UPON RECORD DOCUMENTS AND FIELD SURVEYS. ACTUAL ROUTE OF CONCEALED PIPING MAY VARY. CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY PIPE ROUTING PRIOR TO SAW CUTTING OF FLOOR SLABS. 2. CONTRACTOR SHALL JET AND THOROUGHLY FLUSH EXISTING SANITARY SEWERS WHERE DOCUMENTS CALL FOR NEW WASTE PIPE CONNECTIONS. 3. ALL UNDERGROUND SANITARY OR STORM PIPING SHOWN TO BE ABANDONED IN PLACE SHALL BE CAPPED AND FILLED WITH FLOWABLE FILL. 4. WHERE PLUMBING FIXTURE ROUGH-IN PIPING IS SHOWN TO BE ABANDONED IN WALLS OR BELOW FLOOR SLAB, ROUGH-INS SHALL BE REMOVED TO A POINT BEYOND THE FINISHED SURFACE AND CAPPED. PATCH SURFACE TO MATCH EXISTING FINISH. 5. IN AREAS WHERE A FULL REMODEL IS INDICATED ON THE DRAWINGS, CONTRACTOR SHALL REMOVE ALL OVERHEAD PIPING AND HANGERS COMPLETE UNLESS OTHERWISE INDICATED. 6. WHERE SANITARY OR ACID VENT THROUGH ROOF IS SHOWN TO BE ABANDONED IN PLACE, CONTRACTOR SHALL PERMANENTLY CAP PIPE ABOVE AND BELOW ROOF FOR A WATER TIGHT SEAL. PLUMBING RENOVATION NOTES SK-1 SI-1 EX. 2" W 2" W 1/2" HW EX. 1/2" CW 1 1/2" V 1/2" HW 1 1/2" V EX. 1/2" CW SK-3 EWES-1 SK-2 SK-2 SK-2 SK-2 3/4" HW 1" CW 1/2" CW 1/2" HW 1" CW 3/4" HW 1" CW 3/4" HW 1" CW 3/4" HW 3/4" CW 1/2" HW 1/2" CW 3/4" CW 3/4" HW 3/4" CW 3/4" HW 3/4" CW 1/2" HW 1/2" CW 1/2" HW 1/2" CW 1/2" HW 1/2" CW 1/2" HW 1/2" HW 1/2" CW ELECTRICAL LEGEND & SYMBOLS • EXIT SIGN • DIRECTIONAL ARROWS AS INDICATED • SHADING INDICATES ILLUMINATED FACE • CONNECT TO UNSWITCHED BRANCH CIRCUIT INDICATED • END / WALL / CEILING • LIGHTING FIXTURE • TYPE AS INDICATED • POLE MOUNTED LIGHT FIXTURE • TYPE AS INDICATED • EMERGENCY BATTERY WALL PACK • TYPE AS INDICATED • SHADING INDICATES EMERGENCY FIXTURE CONNECTED TO BATTERY INVERTER OR GENERATOR • CONNECT BATTERY INVERTER TO UNSWITCHED SOURCE IN ADDITION TO SWITCHING INDICATED • TRACK AND TRACK LIGHT FIXTURE • LIGHT FIXTURE • TYPE AS INDICATED • WALL MOUNTED FIXTURE • TYPE AS INDICATED LIGHTING SUBSCRIPTS FOR LIGHTING FIXTURES INDICATE THE FOLLOWING, U.O.N. NL - NIGHT LIGHT, PANEL SWITCHED, U.O.N. POWER DISTRIBUTION • POWER DISTRIBUTION PANELBOARD • 208Y / 120V; 3Ø, 4W • FLOOR / SURFACE • BRANCH CIRCUIT PANELBOARD • 208Y/120V OR 480Y/277V; 3Ø, 4W • FLUSH / SURFACE • TERMINAL CABINET, TYPE AS NOTED ON DRAWINGS • FLUSH / SURFACE • DRY- TYPE TRANSFORMER, RATING AS INDICATED • HOUSEKEEPING PAD • SWITCHBOARD W/MAIN CIRCUIT BREAKER SECTION • HOUSEKEEPING PAD • AUTOMATIC TRANSFER SWITCH • WORKING CLEARANCE ABOUT ELECTRICAL EQUIPMENT • ELECTRIC MANHOLE • GROUND ROD • MOTOR - "M" INDICATES HORSEPOWER • HEAVY-DUTY, NON-FUSED DISCONNECT SWITCH (DS-#) • HEAVY-DUTY, FUSED DISCONNECT SWITCH (DS-#) • COMBINATION MOTOR STARTER AND DISCONNECT SWITCH (MS-#) • VARIABLE FREQUENCY DRIVE (MS-#) • FRACTIONAL HOURSEPOWER MANUAL CONTROLLER WITH THERMAL OVERLOADS (MS-#) CONDUCTOR SIZE SINGLE PHASE MAXIMUM BRANCH CIRCUIT CONDUCTOR LENGTHS (FEET) #12 #8 #6 #4 #3 #2 #1 BRANCH CIRCUIT BREAKER SIZE #10 120 VOLT 55 20A-1P 30A-1P 95 145 230 355 440 540 660 N/A 65 95 150 235 290 360 440 208 VOLT 100 20A-2P 30A-2P 165 255 400 620 760 935 1145 N/A 110 170 265 415 505 625 765 277 VOLT 135 20A-1P 30A-1P 220 340 535 825 1015 1250 1525 N/A T T T T T T H M H H M H GFCI GFCI V S J H H GFCI GFCI GFCI V V H M V M V PT V AR V J AR AR AR J J 5 6 7 8 4 9 A 2 1 B C D E 10 11 12 H J K L F G A5 A4 A3 A2 A1 5 E.P 6 7 8 H V H M H D V TV M H S J H V H J CR CR 5 6 7 8 4 9 A 2 1 B C D E 10 11 12 H J K L F G A5 5 E.P 6 7 8 4 9 A 2 1 B C D E 10 11 12 H J K L F G A5 E.P G1 G2 D V V V S F H M S F H D D GFCI GFCI V V V H H J V PR PT PR 5 A 1 2 B C D G A1 A2 A3 A4 A5 E.P 5 A 1 2 B C D G A1 A2 A3 A4 A5 E.P FAP PNL-1 MS 1 3 5 5 4 4 3 6 2 3 5 5 5 5 5 2 5 8 5 5 5 5 5 5 6 7 8 4 9 A 2 1 B C D E 10 11 12 H J K L F G A5 5 E.P 6 7 8 4 9 A 2 1 B C D E 10 11 12 H J K L F G A5 E.P G1 G2 P L1 1 2 3 2 4 5 6 6 3 3 3 3 3 3 3 D D O1 O1 O1 O1 5 A 1 2 B C D G A1 A2 A3 A4 A5 E.P 5 A 1 2 B C D G A1 A2 A3 A4 A5 E.P PNL-1 3 3 3 3 3 3 9 9 3 3 2 2 1 6 2 3 1 7 7 7 7 10 6 11 11 KITCHEN B128 COPIER B109 PRE-K B132 OFFICE B131 CLASSROOM B130 CLASSROOM B126 CLASSROOM B121 CLASSROOM B120 CLASSROOM B110 CAFETERIA T T V H M H V TV S J H V H CR GFCI GFCI GFCI V M V AR S D S D S D J AR ARAR J J J J J 5 6 7 8 4 9 A 2 1 B C D E 10 11 12 H J K L F G A5 5 E.P 6 7 8 4 9 A 2 1 B T T T T T V V V S F H M S F H GFCI GFCI V V V H H V V V H M V PT V V 5 A 1 2 B C D G A1 A2 A3 A4 A5 E.P 5 A 1 2 B C D G A1 A2 A3 A4 A5 E.P PNL-1 KITCHEN B128 COPIER B109 PRE-K B132 OFFICE B131 CLASSROOM B130 CLASSROOM B126 CLASSROOM B121 4" SQ. COMBO BOX SINGLE GANG PLASTER RING WITH GROUND SCREW AND PIGTAIL TO MATCH DRYWALL THICKNESS 9/32" DIA. STEEL ROD SUSPENSION FROM BLDG. STRUCTURE WITHIN 3' OF OUTLET BOX 8' MAX. SPACING BETWEEN HANGERS STEEL OUTLET BOX - SIZED PER N.E.C. AND SUPPORTED RIGIDLY FROM STRUCTURE CONDUIT 6' MAX. LENGTH - 3/8" FLEX CONDUIT W/ 3-#12 CONDUCTORS FACTORY WIRE INTO FIXTURE TYPICAL LAY-IN RECESSED LIGHT FIXTURE SECURE FIXTURES TO GRID WITH CLIPS PER N.E.C. T-BAR LAY-IN CEILING SUSPENSION SYSTEM UTILIZE CHAIN FOR SUPPORT 3' MAX. FROM BOX TO HANGER CONDUIT CLAMP NOTE: DO NOT SUPPORT CONDUIT OR BOX FROM CEILING GRID HANGERS P N G P N G G P N CONDUIT WIRE NUT GROUND SCREW #10X32X3/8" SLOTTED HEX HEAD WASHER FACE TAPPED HOLE IN BOX T AND B EYE TERMINAL (INSULATED) DEVICE YOKE OUTLET BOX GROUND CONNECTIONS SHALL BE CONTINUOUS SO THAT REMOVAL OF DEVICE WILL NOT INTERFERE WITH CONDUCTOR CONTINUITY 6.35mm (1/4") SCREW GENERAL NOTE: 1. INSTALL IN ACCORDANCE WITH MANUFACTURER'S MOUNTING INSTRUCTIONS AND USING THE RECOMMENDED MOUNTING HARDWARE. ARCHITECTURAL CEILING GRID N 6 5 4 3 2 1 A B C D E 6 5 4 3 2 1 A B C D E Project No. Project Date Produced These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect. KEY PLAN B A 5/22/2023 10:17:48 AM C:\_RevitLocal\2023-067.POR_Bldg001_E_2023\2023-067.POR_Bldg001_E_2023_smathis.rvt 2023-067.POR 05.22.2023 LIGHTING AND EQUIPMENT SCHEDULES E-601 SACM JNS Coram Deo Academy Phase One Renovations 2023-067.POR_Coram Deo Academy_Phase One Renovations_ 525 Congressional Blvd, Carmel, IN 46032 E-601_ LIGHTING AND EQUIPMENT SCHEDULES GENERAL LIGHT FIXTURE SCHEDULE NOTES # NOTES A PROVIDE ALL FIXTURES AND FIXTURE INSTALLATIONS IN ACCORDANCE WITH NEC, NFPA, AND LOCAL CODES. PROVIDE UL LISTED FIXTURES AND INSTALL IN ACCORDANCE WITH THE LISTING. B COORDINATE ALL FIXTURE DEVICES, COMPONENTS, FITTINGS, SUPPORTS, ETC. REQUIRED FOR A COMPLETE UL LISTED INSTALLATION. C PROVIDE ALL DRIVERS, LED MODULES, LENSES, ETC. AS REQUIRED FOR A COMPLETE AND OPERATIONAL LIGHTING UNIT. D BID ONLY THE LIGHTING MANUFACTURERS/SERIES SPECIFIED IN THE LIGHT FIXTURE SCHEDULE. A DOCUMENTED PRE-BID SUBMITTAL MUST BE APPROVED BY THE ENGINEER OF THE PROJECT FOR ANY ADDITION/SUBSTITUTION OF THE MANUFACTURERS LISTED DURING BIDDING. APPROVED MANUFACTURERS WILL BE ADDED/MODIFIED ONLY BY ADDENDUM. E COORDINATE LIGHTING SYSTEM REQUIREMENTS, INCLUDING BUT NOT LIMITED TO, THE LIGHT FIXTURE SCHEDULE, PLANS, PLAN NOTES, DETAILS, SCHEMATICS, SPECIFICATIONS, ETC. F REFER TO LIGHT FIXTURE SCHEDULE, LIGHTING PLANS, AND ARCHITECTURAL REFLECTED CEILING PLANS FOR ALL CEILING TYPES, FINAL LOCATIONS, Transmittal Page 1 of 1 PROJECT: Phase One Renovations 2023-067.POR DATE: 5/22/2023 SUBJECT: Coram Deo Phase 01 Bid Set TRANSMITTAL ID: 00001 PURPOSE: For your use VIA: Info Exchange FROM NAME ADDRESS EMAIL & PHONE Meghan Miller Schmidt Associates 415 Massachusetts Avenue Indianapolis, IN 46204-1501 mmiller@schmidt-arch.com (317) 263-6226 TO NAME ADDRESS EMAIL & PHONE Isaac Dzula Charles C. Brandt Construction Co. 1505 North Sherman Drive Indianapolis, IN 46201 idzula@ccbrandt.com (317) 375-1111 REMARKS: DESCRIPTION OF CONTENTS QTY DATED TITLE NOTES 1 5/22/2023 2023-067.POR_FINAL MANUAL.pdf 1 5/22/2023 5.1 - General.pdf 1 5/19/2023 5.2 - Site.pdf 1 5/22/2023 5.4 - Architecture.pdf 1 5/22/2023 5.5 - Interiors.pdf 1 5/22/2023 5.7 - Mechanical.pdf 1 5/22/2023 5.8 - Plumbing.pdf 1 5/22/2023 5.9 - Electrical.pdf COPIES: Jen Carroll (Schmidt Associates) Dustin Corbett (Charles C. Brandt Construction Co.) ELEVATIONS, AND FIXTURE LENGTHS REQUIRED. G LUMEN VALUES LISTED IN THE LIGHT FIXTURE SCHEDULES ARE THE MINIMUM DELIVERED LUMENS ALLOWED. PROVIDE LIGHT FIXTURES EQUAL TO OR EXCEEDING THE LISTED VALUES. H COORDINATE AND PROVIDE LIGHTING/DIMMING CONTROLS COMPATIBLE WITH ALL FIXTURES, DRIVERS, LED MODULES, ETC. I PROVIDE SELF-DIAGNOSTICS AND SELF-TESTING FOR ALL EMERGENCY FIXTURES (EXIT SIGNS, WALL PACKS, INVERTERS, ETC.). J PROVIDE A MINIMUM OUTPUT OF 900 LUMENS FOR POINT SOURCE FIXTURES AND 1,200 LUMENS FOR LINEAR FIXTURES ON ALL FIXTURES DESIGNED AS EMERGENCY (CONTAINING INTERNAL BATTERY INVERTERS). PROVIDE ILLUMINATION LASTING A MINIMUM OF 90 MINUTES. K VERIFY THE VOLTAGE OF ALL FIXTURES. REFER TO PLANS FOR SPECIFIC VOLTAGE REQUIREMENTS. L PROVIDE FACTORY INSTALLED DISCONNECTING MEANS FOR EACH FIXTURE WITH SERVICEABLE COMPONENTS. M THE ENGINEER RESERVES THE RIGHT TO SELECT FROM ALL AVAILABLE STANDARD COLORS FOR FIXTURES, POLES, MOUNTING ACCESSORIES, ETC. DURING SUBMITTAL REVIEW. N PROVIDE FIXTURES WITH CUSTOM COLORS/FINISH AS SELECTED BY THE ENGINEER WHERE INDICATED. O PAINT AFTER FABRICATION WITH NO SHARP EDGES FOR ALL LIGHT FIXTURES. P PROVIDE APPROPRIATE SLOPE ADAPTERS, FLANGE KITS, TRIMS, AND ALL OTHER MOUNTING ACCESSORIES AS REQUIRED FOR THE CEILING TYPE. Q PROVIDE SPRING-LOADED CAM LATCHES FOR ALL LINEAR FIXTURES UTILIZING A HINGED DOOR. R PROVIDE VIBRATION DAMPERS FOR ALL ALUMINUM & STEEL POLES 20’-0” AND ABOVE. S PROVIDE UL 1449, 20KV SURGE PROTECTION DEVICES FOR ALL EXTERIOR FIXTURES. PROVIDE IN-LINE FUSES WITH 600 VOLT LAMP HOLDERS FOR ALL POLE-MOUNTED FIXTURES. 265119/265619/26213.1 - INTERIOR/EXTERIOR/EMERGENCY & EXIT LIGHT FIXTURES SCHEDULE LABEL DESCRIPTION VOLTAGE SOURCE TYPE LUMENS WATTS CCT MOUNTING LENS/REFLECTOR CERTIFICATIONS ACCEPTABLE MANUFACTURERS LABEL L1 2X2 LED FLAT PANEL. 0-10V DIMMING. SELECTABLE COLOR TEMPERATURE AND LUMEN OUTPUT. SET TO 3500K AND 2,500 LM. 120/277 V LED 2,500/3,200/4,0 00 LM SELECTABLE 40 W 3500K/4000K/5 000K SELECTABLE RECESSED IN GRID SATIN WHITE DLC METALUX CGTS COLUMBIA CBT LITHONIA CPX L1 L2 2X4 LED FLAT PANEL. 0-10V DIMMING. SELECTABLE COLOR TEMPERATURE AND LUMEN OUTPUT. SET TO 3500K AND 6,000 LM. 120/277 V LED 4,000/5,000/6,0 00 LM SELECTABLE 50 W 3500K/4000K/5 000K SELECTABLE RECESSED IN GRID SATIN WHITE DLC METALUX CGTS COLUMBIA CBT LITHONIA CPX L2 X1C1 LED EXIT LIGHT, WHITE FINISH, SINGLE FACE. STENCIL FACE, RED LETTERS. SELF-POWERED. NICKEL-CADMIUM BATTERY. SELF-DIAGNOSTIC/SELF-TESTING MODULE. 120/277 V LED N/A 5 W N/A UNIVERSAL N/A N/A SURE-LITES CX DUAL-LITE SE LITHONIA LE X1C1 262816.1 - ENCLOSED SWITCHES & CIRCUIT BREAKERS SCHEDULE LABEL LOCATION EQUIPMENT SERVED EQUIPMENT RATINGS ACCESSORIES NUMBER NAME VOLTAGE POLES AMPERAGE FUSED FUSE SIZE NEMA ENCL REMARKS AUX. CONTACTS SOLID NEUTRAL 262913/262923.1 - ENCLOSED & VARIABLE-FREQUENCY MOTOR CONTROLLERS SCHEDULE LABEL LOCATION EQUIPMENT SERVED EQUIPMENT RATINGS STARTER DISCONNECT SWITCH REMOTE NUMBER NAME VOLTAGE PHASE HP FLA NEMA ENCL TYPE NEMA SIZE TYPE FUSE SIZE CAPACITOR REMARKS MS-A1 A121 SCIENCE LAB EF-A1 120 V 1 1/4 5.8 A - 1 - - - - FRACTIONAL HORSEPOWER RATED TOGGLE SWITCH WITH THERMAL OVERLOADS # Revision Date LOCKING SQUARE WASHER & NUT ACOUSTICAL JUNCTION BOX CEILING TILE (TYP) ARCHITECTURAL CEILING GRID WIRE TIE THROUGH MOUNTING CHANNEL & CROSS BEAM (TYP) ARCHITECTURAL CEILING GRID CEILING HANGER WIRE FIXTURE WHIP FROM JUNCTION BOX (1829mm (6') LONG MAX) HANGER WIRE AND MOUNTING CHANNEL ATTACHED TO STRUCTURE REFER TO SPECIFICATION SECTION 26 51 00 INTEGRAL GALVANIZED LIPPED STEEL MOUNTING CHANNEL CADDY COMBINATION CONDUIT HANGER CLAMP OR EQUAL SUPPORT STRUCTURE CADDY STRUT CLIP OR EQUAL ROD SIZE AS REQUIRED CADDY ROD HANGER CLAMP OR EQUAL CADDY CONDUIT CLAMP OR EQUAL. SIZE AS REQUIRED UNISTRUT CHANNEL OR EQUAL 1ST FLOOR EXISTING REMOTE ANNUNCIATOR PANEL NOTES: 1. REFER TO FLOOR PLANS FOR DEVICE QUANTITIES 2. ALL VISUAL DEVICES AND HORN/STROBES TO BE SYNCHRONIZED FLASH EXISTING FIRE ALARM CONTROL PANEL F R F S M EXISTING FIRE ALARM NAC PANEL 120V CIRCUIT V H NOTES: SUPPORTING CABLE IS ACCEPTIBLE BELOW SUPPORT STEEL OR ABOVE STEEL. COORDINATE MOUNTING LOCATIONS WITH OTHER TRADES AND FIELD CONDITIONS. PROVIDE SUPPORT CLIPS AND THREADED RODES AS REQUIRED FOR A COMPLETE SUPPORT SYSTEM AS INDICATED. SUPPORT CABLES FROM EITHER PARALLEL OR PERPENDICULAR SUPPORT STEEL. BUNDLE A UP TO A MAXIMUM OF (6) SIX CABLES. 1. 2. 3. TYPICAL BEAM OR STRUCTURAL SUPPORT TYPICAL BEAM CLAMP BOLTED, THREADED TYPE 1/4" THREADED ROD PROVIDE CHECKNUT TYPICAL MC OR AC CABLE SUPPORT MAX. 5'-0" O.C. FLEXIBLE CABLE SUPPORT CLIPS, CADDY FASTENER NO. PCS1 OR APPROVED EQUAL (TYPICAL). N 6 5 4 3 2 1 A B C D E 6 5 4 3 2 1 A B C D E Project No. Project Date Produced These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect. KEY PLAN B A 5/22/2023 10:17:36 AM C:\_RevitLocal\2023-067.POR_Bldg001_E_2023\2023-067.POR_Bldg001_E_2023_smathis.rvt 2023-067.POR 05.22.2023 GENERAL DETAILS E-501 SACM JNS Coram Deo Academy Phase One Renovations 2023-067.POR_Coram Deo Academy_Phase One Renovations_ 525 Congressional Blvd, Carmel, IN 46032 E-501_ GENERAL DETAILS 1A NOT TO SCALE RECEPTACLE SUPPORT DETAIL 2A NOT TO SCALE RECESSED LIGHTING INSTALLATION # Revision Date 1B NOT TO SCALE DEVICE GROUNDING DETAIL 4A NOT TO SCALE EXIT SIGN MOUNTING - LAY-IN CEILING DETAIL 2B NOT TO SCALE CONDUIT 2" AND SMALLER SUPPORT DETAIL 4B NOT TO SCALE CONDUIT 2-1/2" AND LARGER SUPPORT DETAIL 1D NOT TO SCALE FIRE ALARM SCHEMATIC 5D NOT TO SCALE METAL CLAD (MC) CABLE STRUCTURAL SUPPORT DETAIL CLASSROOM B120 CLASSROOM B110 CAFETERIA B111A KITCHENETTE B122 PLUMBING B123 OFFICE B124 CLASSROOM B119 MENS RR B149 OFFICE B147 OFFICE B119A CLASSROOM B118 STORAGE B146A CLASSROOM B145 STORAGE B144 STORAGE B143 STORAGE B142 COMMONS B141 STORAGE B140 STORAGE B139 CORRIDOR B001 Unoccupied Unoccupied CLASSROOM B138 CLASSROOM B127 WOMENS RR B148 STORAGE B129A LIBRARY B135 CLASSROOM B136 IDF B129 CAFETERIA B111A STORAGE B146 STORAGE B129B CLASSROOM B121 KITCHENETTE B122 CORRIDOR B001 CLASSROOM B121 KITCHENETTE B122 CORRIDOR B001 2 2 2 2 2 1 1 CIRCUIT 3 1 CIRCUIT 3 CIRCUIT 3 CIRCUIT 4 CIRCUIT 4 1 1 ECUH-2 ECUH-1 7 F20 7 F20 A B A1 A B A1 2 N 6 5 4 3 2 1 A B C D E 6 5 4 3 2 1 A B C D E Project No. Project Date Produced These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect. KEY PLAN B A 5/22/2023 1:03:01 PM C:\_RevitLocal\2023-067.POR_Bldg001_E_2023\2023-067.POR_Bldg001_E_2023_jboosey.rvt 2023-067.POR 05.22.2023 FIRST FLOOR POWER PLAN - UNIT B EP1B1 SACM JNS Coram Deo Academy Phase One Renovations 2023-067.POR_Coram Deo Academy_Phase One Renovations_ 525 Congressional Blvd, Carmel, IN 46032 EP1B1_ FIRST FLOOR POWER PLAN - UNIT B POWER PLAN NOTES # NOTES 1 CONNECT TO NEAREST SPARE 120V-1P, 20A CIRCUIT. TEXT NEXT TO PLAN NOTE INDICATED CIRCUIT GROUPING. 2 RECEPTACLE FOR PROJECTOR LOCATED FLUSH WITH CEILING TILE/IN PROJECTOR PAN. COORDINATE LOCATION OF RECEPTACLE WITH OWNER PRIOR TO INSTALLATION. CONNECT TO NEAREST 120V, 20A-1P SPARE CIRCUIT BREAKER. 3 CIRCUIT CONNECTION FOR EMERGENCY GAS SHUTOFF VALVE. PROVIDE ALL CONDUIT AND WIRING BETWEEN CONTROL PANEL AND SOLENOID VALVES/EMERGENCY SHUTOFF BUTTONS AS INDICATED ON P-SERIES DRAWINGS. PROVIDE FIRE ALARM ADDRESSABLE RELAY IN SERIES WITH SHUTOFF BUTTON WIRNG SUCH THAT GAS VALVES WILL CLOSE ON AN ALARM IN FIRE ALARM SYSTEM. CONNECT TO NEAREST SPARE DEDICATED 20A-1P, 120V CIRCUIT BREAKER. 4 CONNECT TO NEAREST DEDICATED SPARE 120V-1P, 20A CIRCUIT. 5 PROVIDE MOTOR STARTER IN FUME HOOD. COORDINATE INSTALLATION WITH MANUFACTURER. CONNECT TO EXHAUST FAN ON ROOM. DISCONNECT IN EXHAUST FAN BY EXHAUST FAN MANUFACTURER. 6 TIE MOTOR STARTER FOR FUME HOOD TO MANUFACTURER PROVIDED DISCONNECT IN EXHAUST FAN. PROVIDE NEW GRCI/WEATHER PROOF DUPLEX RECEPACLE AT EXHAUST FAN. TIE INTO NEAREST DEDICATED 20A-1P, 120V CIRCUIT BREAKER. 7 CONNECT MECHANICAL EQUIPMENT TO NEAREST SPARE DEDICATED 20A-1P, 277V CIRCUIT BREAKER. CONNECT TO MANUFACTURER PROVIDED DISCONNECT IN UNIT. 8 PROVIDE DEDICATED SINGLE 120V, 1P-20A CIRCUIT TO ALL SMOKE OR FIRE/SMOKE DAMPER MOTORS INDICATED. CONNECT CIRCUIT THROUGH FIRE ALARM ADDRESSABLE RELAY. DAMPER WILL CLOSE WHEN DUCT DETECTORS DETECT SMOKE. PROVIDE WIRING TO CONNECT TO REMOTE DAMPER TEST SWITCH BY DIVISION 23 CONTRACTOR. REFER TO SCHEMATICS AND M-SERIES SHEETS FOR MORE INFORMATION AND TEST SWITCH LOCATION. 9 PROVIDE DUCT DETECTOR FOR FIRE/SMOKE DAMPERS. 10 PROVIDE OWNER PROVIDED CARD READER ROUGH IN 46" A.F.F. GENERAL POWER NOTES # NOTES A REFER TO SHEETS E-001 AND E-002 FOR ADDITIONAL INFORMATION. B ALL PRODUTS TO BE HANDLED, STORED, AND INSTALLED PER MANUFACTURER REQUIREMENTS. C COMPLY WITH ALL APPLICABLE CODES AND REGULATIONS PERTAINING TO THIS SCOPE OF WORK. D FOR BIDDING PURPOSES, ASSUME A PANELBOARD WITH SPARE BREAKERS IS WITHIN 100' OF EDGE OF ROOM TO ROOM WITH PANELBOARD. 2A 1/8" = 1'-0" FIRST FLOOR POWER PLAN - UNIT B 5D 1/8" = 1'-0" ALTERNATE - POWER # Revision Date C D E 10 11 12 H J K L F G A5 E.P G1 G2 P L1 1 1 1 1 1 PARENT ROOM B100 COPIER B109 STORAGE B112 CLASSROOM B120 CLASSROOM B110 CAFETERIA B111A PARENT ROOM B100 STORAGE B112 LOBBY A100 CLINIC A101 OFFICE A102 OFFICE A104 STORAGE A106A SCIENCE LAB A121 OFFICE A119 CLASSROOM A120 CLASSROOM A118 BREAK ROOM A106 OFFICE A105 OFFICE A103 CORRIDOR A001 UNOCCUPIED A122 UNOCCUPIED A123 UNOCCUPIED A124 UNOCCUPIED A125 UNOCCUPIED A126 UNOCCUPIED A127 UNOCCUPIED A128 UNOCCUPIED A129 UNOCCUPIED A130 CLASSROOM A113 CLASSROOM A116 OFFICE A114 OFFICE A115 CORRIDOR A003 STORAGE A112 STORAGE A111 STORAGE A117 GYM A110 ELECTRICAL A112A CLASSROOM B117 PRACTICE ROOM B117A CLASSROOM B115 PRACTICE ROOM B116 PRACTICE ROOM B114 PRACTICE ROOM B113 OFFICE B115A STORAGE B115B STORAGE B115C OFFICE B107 OFFICE B108 OFFICE B106 OFFICE B105 VESTIBULE A003B VESTIBULE A100A CORRIDOR A002 VESTIBULE A110B RR A110C EP1A1 2E RPB-2 MGP-1 2 2 CIRCUIT 1 CIRCUIT 2 CIRCUIT 1 CIRCUIT 2 CIRCUIT 1 MS-A1 4 5 F20 3 F20 2 9 9 GFCI GFCI 9 8 10 10 11 K L G 10 11 K L G EF-A1 6 GFCI/WP N 6 5 4 3 2 1 A B C D E 6 5 4 3 2 1 A B C D E Project No. Project Date Produced These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect. KEY PLAN B A 5/22/2023 1:02:50 PM C:\_RevitLocal\2023-067.POR_Bldg001_E_2023\2023-067.POR_Bldg001_E_2023_jboosey.rvt 2023-067.POR 05.22.2023 FIRST FLOOR POWER PLAN - UNIT A EP1A1 SACM JNS Coram Deo Academy Phase One Renovations 2023-067.POR_Coram Deo Academy_Phase One Renovations_ 525 Congressional Blvd, Carmel, IN 46032 EP1A1_ FIRST FLOOR POWER PLAN - UNIT A POWER PLAN NOTES # NOTES 1 CONNECT TO NEAREST SPARE 120V-1P, 20A CIRCUIT. TEXT NEXT TO PLAN NOTE INDICATED CIRCUIT GROUPING. 2 RECEPTACLE FOR PROJECTOR LOCATED FLUSH WITH CEILING TILE/IN PROJECTOR PAN. COORDINATE LOCATION OF RECEPTACLE WITH OWNER PRIOR TO INSTALLATION. CONNECT TO NEAREST 120V, 20A-1P SPARE CIRCUIT BREAKER. 3 CIRCUIT CONNECTION FOR EMERGENCY GAS SHUTOFF VALVE. PROVIDE ALL CONDUIT AND WIRING BETWEEN CONTROL PANEL AND SOLENOID VALVES/EMERGENCY SHUTOFF BUTTONS AS INDICATED ON P-SERIES DRAWINGS. PROVIDE FIRE ALARM ADDRESSABLE RELAY IN SERIES WITH SHUTOFF BUTTON WIRNG SUCH THAT GAS VALVES WILL CLOSE ON AN ALARM IN FIRE ALARM SYSTEM. CONNECT TO NEAREST SPARE DEDICATED 20A-1P, 120V CIRCUIT BREAKER. 4 CONNECT TO NEAREST DEDICATED SPARE 120V-1P, 20A CIRCUIT. 5 PROVIDE MOTOR STARTER IN FUME HOOD. COORDINATE INSTALLATION WITH MANUFACTURER. CONNECT TO EXHAUST FAN ON ROOM. DISCONNECT IN EXHAUST FAN BY EXHAUST FAN MANUFACTURER. 6 TIE MOTOR STARTER FOR FUME HOOD TO MANUFACTURER PROVIDED DISCONNECT IN EXHAUST FAN. PROVIDE NEW GRCI/WEATHER PROOF DUPLEX RECEPACLE AT EXHAUST FAN. TIE INTO NEAREST DEDICATED 20A-1P, 120V CIRCUIT BREAKER. 7 CONNECT MECHANICAL EQUIPMENT TO NEAREST SPARE DEDICATED 20A-1P, 277V CIRCUIT BREAKER. CONNECT TO MANUFACTURER PROVIDED DISCONNECT IN UNIT. 8 PROVIDE DEDICATED SINGLE 120V, 1P-20A CIRCUIT TO ALL SMOKE OR FIRE/SMOKE DAMPER MOTORS INDICATED. CONNECT CIRCUIT THROUGH FIRE ALARM ADDRESSABLE RELAY. DAMPER WILL CLOSE WHEN DUCT DETECTORS DETECT SMOKE. PROVIDE WIRING TO CONNECT TO REMOTE DAMPER TEST SWITCH BY DIVISION 23 CONTRACTOR. REFER TO SCHEMATICS AND M-SERIES SHEETS FOR MORE INFORMATION AND TEST SWITCH LOCATION. 9 PROVIDE DUCT DETECTOR FOR FIRE/SMOKE DAMPERS. 10 PROVIDE OWNER PROVIDED CARD READER ROUGH IN 46" A.F.F. GENERAL POWER NOTES # NOTES A REFER TO SHEETS E-001 AND E-002 FOR ADDITIONAL INFORMATION. B ALL PRODUTS TO BE HANDLED, STORED, AND INSTALLED PER MANUFACTURER REQUIREMENTS. C COMPLY WITH ALL APPLICABLE CODES AND REGULATIONS PERTAINING TO THIS SCOPE OF WORK. D FOR BIDDING PURPOSES, ASSUME A PANELBOARD WITH SPARE BREAKERS IS WITHIN 100' OF EDGE OF ROOM TO ROOM WITH PANELBOARD. 1/8" = 1'-0" 1A FIRST FLOOR POWER PLAN - UNIT A 1/8" = 1'-0" 2E ROOF PLAN - A121 # Revision Date B111A KITCHENETTE B122 PLUMBING B123 OFFICE B124 CLASSROOM B119 MENS RR B149 OFFICE B147 OFFICE B119A CLASSROOM B118 STORAGE B146A CLASSROOM B145 STORAGE B144 STORAGE B143 STORAGE B142 COMMONS B141 STORAGE B140 STORAGE B139 CORRIDOR B001 CLASSROOM B138 CLASSROOM B127 WOMENS RR B148 STORAGE B129A LIBRARY B135 CLASSROOM B136 IDF B129 CAFETERIA B111A STORAGE B146 STORAGE B129B L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 5 9 8 8 12 8 5 9 9 9 9 9 13 5 X1C1 X1C1 L1 13 L2 L2 L2 L2 L2 L2 L2 L2 14 15 14 5 11 16 A B A1 A B A1 3 2 1 3 2 N 6 5 4 3 2 1 A B C D E 6 5 4 3 2 1 A B C D E Project No. Project Date Produced These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect. KEY PLAN B A 5/22/2023 10:18:47 AM C:\_RevitLocal\2023-067.POR_Bldg001_E_2023\2023-067.POR_Bldg001_E_2023_smathis.rvt 2023-067.POR 05.22.2023 FIRST FLOOR LIGHTING PLAN - UNIT B EL1B1 SACM JNS Coram Deo Academy Phase One Renovations 2023-067.POR_Coram Deo Academy_Phase One Renovations_ 525 Congressional Blvd, Carmel, IN 46032 EL1B1_ FIRST FLOOR LIGHTING PLAN - UNIT B LIGHTING PLAN NOTES # NOTES 1 EXISTING LIGHTS TO REMAIN. MODIFY CIRCUIT AS REQUIRED FOR NEW LIGHTING CONTROLS. 2 RECESS TOGGLE SWITCH IN EXISTING WALL. 3 PROVIDE NEW LIGHT SWITCH IN EXISTING LOCATION. 4 REINSTALL EXISTING LIGHTS FROM DEMOLITION. MODIFY EXISTING LIGHTING CIRCUIT AS REQUIRED FOR NEW LIGHTING CONTROL. 5 RELOCATE EXISTING EXIT SIGN. 6 REINSTALL EXISTING LIGHTING(S) FROM DEMOLITION. CONNECT TO EXISTING LIGHTING CIRCUIT AND NEW CONTROLS IN ROOM AS INDICATED. 7 RECONNECT EXISTING EMERGENCY WALLPACK TO CIRCUIT FROM DEMOLITION. 8 RELOCATE EXISTING LIGHT SWITCH FROM DEMOLITION. 9 RELOCATE EXISTING EMERGENCY WALLPACK LIGHT(S). 10 REINSTALL EXISTING LIGHTS FROM DEMOLITION. MODIFY EXISTING LIGHTING CIRCUIT AS REQUIRED FOR TO TIE INTO ADJACENT ROOMS LIGHTING CONTROL. 11 REINSTALL EXISTING LIGHTING(S) FROM DEMOLITION. CONNECT TO EXISTING LIGHTING CIRCUIT AND CONTROLS IN CORRIDOR. 12 PROVIDE NEW LIGHT SWITCH. 13 PROVIDE NEW EXIT SIGN AND TIE INTO NEAREST CIRCUIT SERVING EXIT SIGNS. 14 PROVIDE NEW LIGHTS AND CONNECT TO NEW SWITCHING AS SHOWN. CONNECT TO EXISTING LIGHTING CIRCUIT FROM DEMOLITION. 15 PROVIDE NEW LIGHT AND CONNECT TO EXISTING CIRCUIT/SWITCHING IN CORRIDOR. 16 RELOCATE EXISTING LIGHTS. GENERAL LIGHTING NOTES # NOTES A REFER TO SHEETS E-001 AND E-002 FOR ADDITIONAL INFORMATION. B PROVIDE CHAIN SUPPORTS TO STRUCTURE FOR EXISTING LIGHT FIXTURES TO REMAIN IN CEILINGS BEING REMOVED AND REINSTALLED. C ALL PRODUTS TO BE HANDLED, STORED, AND INSTALLED PER MANUFACTURER REQUIREMENTS. D COMPLY WITH ALL APPLICABLE CODES AND REGULATIONS PERTAINING TO THIS SCOPE OF WORK. 1/8" = 1'-0" 2A FIRST FLOOR LIGHTING PLAN - UNIT B 1/8" = 1'-0" 5D ALTERNATE - LIGHTING # Revision Date 3 7 7 7 7 2 2 1 6 PARENT ROOM B100 COPIER B109 STORAGE B112 CLASSROOM B121 CLASSROOM B120 CLASSROOM B110 CAFETERIA B111A PARENT ROOM B100 STORAGE B112 5 3 3 N 6 5 4 3 2 1 A B C D E 6 5 4 3 2 1 A B C D E Project No. Project Date Produced These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect. KEY PLAN B A 5/22/2023 10:18:33 AM C:\_RevitLocal\2023-067.POR_Bldg001_E_2023\2023-067.POR_Bldg001_E_2023_smathis.rvt 2023-067.POR 05.22.2023 FIRST FLOOR LIGHTING PLAN - UNIT A EL1A1 SACM JNS Coram Deo Academy Phase One Renovations 2023-067.POR_Coram Deo Academy_Phase One Renovations_ 525 Congressional Blvd, Carmel, IN 46032 EL1A1_ FIRST FLOOR LIGHTING PLAN - UNIT A LIGHTING PLAN NOTES # NOTES 1 EXISTING LIGHTS TO REMAIN. MODIFY CIRCUIT AS REQUIRED FOR NEW LIGHTING CONTROLS. 2 RECESS TOGGLE SWITCH IN EXISTING WALL. 3 PROVIDE NEW LIGHT SWITCH IN EXISTING LOCATION. 4 REINSTALL EXISTING LIGHTS FROM DEMOLITION. MODIFY EXISTING LIGHTING CIRCUIT AS REQUIRED FOR NEW LIGHTING CONTROL. 5 RELOCATE EXISTING EXIT SIGN. 6 REINSTALL EXISTING LIGHTING(S) FROM DEMOLITION. CONNECT TO EXISTING LIGHTING CIRCUIT AND NEW CONTROLS IN ROOM AS INDICATED. 7 RECONNECT EXISTING EMERGENCY WALLPACK TO CIRCUIT FROM DEMOLITION. 8 RELOCATE EXISTING LIGHT SWITCH FROM DEMOLITION. 9 RELOCATE EXISTING EMERGENCY WALLPACK LIGHT(S). 10 REINSTALL EXISTING LIGHTS FROM DEMOLITION. MODIFY EXISTING LIGHTING CIRCUIT AS REQUIRED FOR TO TIE INTO ADJACENT ROOMS LIGHTING CONTROL. 11 REINSTALL EXISTING LIGHTING(S) FROM DEMOLITION. CONNECT TO EXISTING LIGHTING CIRCUIT AND CONTROLS IN CORRIDOR. 12 PROVIDE NEW LIGHT SWITCH. 13 PROVIDE NEW EXIT SIGN AND TIE INTO NEAREST CIRCUIT SERVING EXIT SIGNS. 14 PROVIDE NEW LIGHTS AND CONNECT TO NEW SWITCHING AS SHOWN. CONNECT TO EXISTING LIGHTING CIRCUIT FROM DEMOLITION. 15 PROVIDE NEW LIGHT AND CONNECT TO EXISTING CIRCUIT/SWITCHING IN CORRIDOR. 16 RELOCATE EXISTING LIGHTS. GENERAL LIGHTING NOTES # NOTES A REFER TO SHEETS E-001 AND E-002 FOR ADDITIONAL INFORMATION. B PROVIDE CHAIN SUPPORTS TO STRUCTURE FOR EXISTING LIGHT FIXTURES TO REMAIN IN CEILINGS BEING REMOVED AND REINSTALLED. C ALL PRODUTS TO BE HANDLED, STORED, AND INSTALLED PER MANUFACTURER REQUIREMENTS. D COMPLY WITH ALL APPLICABLE CODES AND REGULATIONS PERTAINING TO THIS SCOPE OF WORK. 1/8" = 1'-0" 1A FIRST FLOOR LIGHTING PLAN - UNIT A # Revision Date 5 5 5 5 A B A1 A B A1 N 6 5 4 3 2 1 A B C D E 6 5 4 3 2 1 A B C D E Project No. Project Date Produced These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect. KEY PLAN B A 5/22/2023 10:18:17 AM C:\_RevitLocal\2023-067.POR_Bldg001_E_2023\2023-067.POR_Bldg001_E_2023_smathis.rvt 2023-067.POR 05.22.2023 FIRST FLOOR DEMOLITION PLAN - UNIT B ED1B1 SACM JNS Coram Deo Academy Phase One Renovations 2023-067.POR_Coram Deo Academy_Phase One Renovations_ 525 Congressional Blvd, Carmel, IN 46032 ED1B1_ FIRST FLOOR DEMOLITION PLAN - UNIT B DEMOLITION PLAN NOTES # NOTES 1 DISCONNECT AND REMOVE EXISTING LIGHTING FIXTURE(S). CLEAN AND RELAMP LIGTHS FOR REINSTALLION INTO NEW GRID. LIGHTINGS CIRCUIT TO REMAIN FOR RECONNECTING TO LIGHTS. 2 RELOCATE EXISTING EXIT SIGN. 3 EXISTING LIGHT SWITCH TO BE RELOCATED. 4 DISCONNECT AND REMOVE POWER POLES SERVING FURNITURE SYSTEMS. 5 RELOCATE EXISTING EMERGENCY WALLPACK LIGHT(S). 5 RELOCATE EXISTING LIGHTS. 6 RELOCATE EXISTING PANEL SERVING FIRE ALARM PANEL TO IDF ROOM COMPLETE. COORDINATE LOCATION WITH OWNER. 7 RELOCATE EXISTING GFCI/COUNTERTOP RECEPTACLE. 8 RELOCATE EXISTING GFCI/COUNTERTOP RECEPTACLE DOWN WALL AS REQUIRED FOR NEW WALL OPENING. GENERAL DEMOLITION NOTES # NOTES A REFER TO SHEETS E-001 AND E-002 FOR ADDITIONAL INFORMATION. B THIS DRAWING REPRESENTS INFORMATION OBTAINED FROM ORIGINAL CONTRACT DRAWINGS AND FIELD SURVEY. VERIFY BY ON-SITE OBSERVATION THE EXTENT OF WORK PRIOR TO SUBMISSION OF BID. C CONTRACT DOCUMENTS CONSIST OF BOTH PROJECT MANUAL AND DRAWINGS AND ARE MEANT TO BE COMPLEMENTARY. ANYTHING APPEARING ON EITHER MUST BE EXECUTED THE SAME AS IF SHOWN ON BOTH. D THOROUGHLY EXAMINE THE WORK OF OTHER CONTRACTORS AND PROPERLY INSTALL ALL WORK REQUIRED FOR THE PROJECT. E THE OWNER HOLDS RIGHT OF FIRST REFUSAL FOR ALL DEMOLISHED ELECTRICAL EQUIPMENT. F ALL ELECTRICAL ITEMS SHOWN WITH LIGHT LINEWORK ARE EXISTING TO REMAIN. G REMOVE ALL ELECTRICAL ITEMS SHOWN WITH BOLD/DASHED LINEWORK COMPLETE. H COORDINATE AND DISCONNECT ALL CIVIL, ARCHITECTURAL, MECHANICAL, PLUMBING, AND TELECOMMUNICATION EQUIPMENT AS NOTED FOR REMOVAL BY OTHERS. REMOVE ALL ASSOCIATED ELECTRICAL EQUIPMENT, RACEWAYS, CONDUCTORS, ETC. SERVING THE EQUIPMENT. I PROVIDE ALL CUTTING AND PATCHING AS REQUIRED FOR THE REMOVAL OF EXISTING ELECTRICAL EQUIPMENT. REFER TO SPECIFICATIONS. J PROVIDE A BLANK COVERPLATE FOR ALL EXISTING WALL OPENINGS WHERE ELECTRICAL EQUIPMENT HAS BEEN REMOVED AND NOT REPLACED. IN AREAS RECEIVING NEW WALL TREATMENTS, PATCH THE EXISTING OPENING. K REFER TO A, M, P, AND T-SERIES DRAWINGS FOR AREAS WITH ABOVE CEILING WORK AND/OR CEILING REMOVAL. TEMPORARILY SUPPORT ALL ELECTRICAL DEVICES, FIXTURES, ETC. AS REQUIRED. RE-INSTALL ELECTRICAL ITEMS FOLLOWING THE COMPLETION OF WORK IN THE NEW OR EXISTING CEILINGS. L REMOVE SYSTEMS AND EQUIPMENT MADE OBSOLETE BY THIS PROJECT. THIS INCLUDES, BUT IS NOT LIMITED TO, CONDUIT, RACEWAYS, WIREWAYS, CONDUCTORS, JUNCTION BOXES, WIRING DEVICES, LIGHT FIXTURES, PULL BOXES, DISCONNECTS, MOTOR STARTERS, CONTACTORS, ETC. M REMOVE ALL DEBRIS FROM SITE AND LEGALLY DISPOSE OF SAME. N REMOVE ALL EXISTING EQUIPMENT PADS MADE OBSOLETE. CUT OFF BELOW FLOOR SLAB AND FILL WITH CONCRETE ALL CONDUITS WHICH ARE ABANDONED IN OR BELOW THE FLOOR SLAB. PATCH FLOOR TO MATCH EXISTING CONDITIONS. O ALL PRODUTS TO BE HANDLED, STORED, AND INSTALLED PER MANUFACTURER REQUIREMENTS. P COMPLY WITH ALL APPLICABLE CODES AND REGULATIONS PERTAINING TO THIS SCOPE OF WORK. 1/8" = 1'-0" 2B FIRST FLOOR DEMOLITION PLAN - UNIT B 1/8" = 1'-0" 5D ALTERNATE - DEMOLITION # Revision Date P L1 FAAP FACP-1 1 1 1 2 1 2 5 5 5 5 5 N 6 5 4 3 2 1 A B C D E 6 5 4 3 2 1 A B C D E Project No. Project Date Produced These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect. KEY PLAN B A 5/22/2023 10:18:02 AM C:\_RevitLocal\2023-067.POR_Bldg001_E_2023\2023-067.POR_Bldg001_E_2023_smathis.rvt 2023-067.POR 05.22.2023 FIRST FLOOR DEMOLITION PLAN - UNIT A ED1A1 SACM JNS Coram Deo Academy Phase One Renovations 2023-067.POR_Coram Deo Academy_Phase One Renovations_ 525 Congressional Blvd, Carmel, IN 46032 ED1A1_ FIRST FLOOR DEMOLITION PLAN - UNIT A DEMOLITION PLAN NOTES # NOTES 1 DISCONNECT AND REMOVE EXISTING LIGHTING FIXTURE(S). CLEAN AND RELAMP LIGTHS FOR REINSTALLION INTO NEW GRID. LIGHTINGS CIRCUIT TO REMAIN FOR RECONNECTING TO LIGHTS. 2 RELOCATE EXISTING EXIT SIGN. 3 EXISTING LIGHT SWITCH TO BE RELOCATED. 4 DISCONNECT AND REMOVE POWER POLES SERVING FURNITURE SYSTEMS. 5 RELOCATE EXISTING EMERGENCY WALLPACK LIGHT(S). 5 RELOCATE EXISTING LIGHTS. 6 RELOCATE EXISTING PANEL SERVING FIRE ALARM PANEL TO IDF ROOM COMPLETE. COORDINATE LOCATION WITH OWNER. 7 RELOCATE EXISTING GFCI/COUNTERTOP RECEPTACLE. 8 RELOCATE EXISTING GFCI/COUNTERTOP RECEPTACLE DOWN WALL AS REQUIRED FOR NEW WALL OPENING. GENERAL DEMOLITION NOTES # NOTES A REFER TO SHEETS E-001 AND E-002 FOR ADDITIONAL INFORMATION. B THIS DRAWING REPRESENTS INFORMATION OBTAINED FROM ORIGINAL CONTRACT DRAWINGS AND FIELD SURVEY. VERIFY BY ON-SITE OBSERVATION THE EXTENT OF WORK PRIOR TO SUBMISSION OF BID. C CONTRACT DOCUMENTS CONSIST OF BOTH PROJECT MANUAL AND DRAWINGS AND ARE MEANT TO BE COMPLEMENTARY. ANYTHING APPEARING ON EITHER MUST BE EXECUTED THE SAME AS IF SHOWN ON BOTH. D THOROUGHLY EXAMINE THE WORK OF OTHER CONTRACTORS AND PROPERLY INSTALL ALL WORK REQUIRED FOR THE PROJECT. E THE OWNER HOLDS RIGHT OF FIRST REFUSAL FOR ALL DEMOLISHED ELECTRICAL EQUIPMENT. F ALL ELECTRICAL ITEMS SHOWN WITH LIGHT LINEWORK ARE EXISTING TO REMAIN. G REMOVE ALL ELECTRICAL ITEMS SHOWN WITH BOLD/DASHED LINEWORK COMPLETE. H COORDINATE AND DISCONNECT ALL CIVIL, ARCHITECTURAL, MECHANICAL, PLUMBING, AND TELECOMMUNICATION EQUIPMENT AS NOTED FOR REMOVAL BY OTHERS. REMOVE ALL ASSOCIATED ELECTRICAL EQUIPMENT, RACEWAYS, CONDUCTORS, ETC. SERVING THE EQUIPMENT. I PROVIDE ALL CUTTING AND PATCHING AS REQUIRED FOR THE REMOVAL OF EXISTING ELECTRICAL EQUIPMENT. REFER TO SPECIFICATIONS. J PROVIDE A BLANK COVERPLATE FOR ALL EXISTING WALL OPENINGS WHERE ELECTRICAL EQUIPMENT HAS BEEN REMOVED AND NOT REPLACED. IN AREAS RECEIVING NEW WALL TREATMENTS, PATCH THE EXISTING OPENING. K REFER TO A, M, P, AND T-SERIES DRAWINGS FOR AREAS WITH ABOVE CEILING WORK AND/OR CEILING REMOVAL. TEMPORARILY SUPPORT ALL ELECTRICAL DEVICES, FIXTURES, ETC. AS REQUIRED. RE-INSTALL ELECTRICAL ITEMS FOLLOWING THE COMPLETION OF WORK IN THE NEW OR EXISTING CEILINGS. L REMOVE SYSTEMS AND EQUIPMENT MADE OBSOLETE BY THIS PROJECT. THIS INCLUDES, BUT IS NOT LIMITED TO, CONDUIT, RACEWAYS, WIREWAYS, CONDUCTORS, JUNCTION BOXES, WIRING DEVICES, LIGHT FIXTURES, PULL BOXES, DISCONNECTS, MOTOR STARTERS, CONTACTORS, ETC. M REMOVE ALL DEBRIS FROM SITE AND LEGALLY DISPOSE OF SAME. N REMOVE ALL EXISTING EQUIPMENT PADS MADE OBSOLETE. CUT OFF BELOW FLOOR SLAB AND FILL WITH CONCRETE ALL CONDUITS WHICH ARE ABANDONED IN OR BELOW THE FLOOR SLAB. PATCH FLOOR TO MATCH EXISTING CONDITIONS. O ALL PRODUTS TO BE HANDLED, STORED, AND INSTALLED PER MANUFACTURER REQUIREMENTS. P COMPLY WITH ALL APPLICABLE CODES AND REGULATIONS PERTAINING TO THIS SCOPE OF WORK. 1/8" = 1'-0" 1A FIRST FLOOR DEMOLITION PLAN - UNIT A # Revision Date 4 9 A 2 1 B C D E 10 11 12 H J K L F G A5 A4 A3 A2 A1 E.P L1 P G1 G2 PNL-1 N 6 5 4 3 2 1 A B C D E 6 5 4 3 2 1 A B C D E Project No. Project Date Produced These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect. KEY PLAN B A 5/22/2023 10:17:23 AM C:\_RevitLocal\2023-067.POR_Bldg001_E_2023\2023-067.POR_Bldg001_E_2023_smathis.rvt 2023-067.POR 05.22.2023 OVERAL BUILDING PLAN E-101 SACM JNS Coram Deo Academy Phase One Renovations 2023-067.POR_Coram Deo Academy_Phase One Renovations_ 525 Congressional Blvd, Carmel, IN 46032 E-101_ OVERAL BUILDING PLAN GENERAL OVERALL BUILDING NOTES # NOTES A REFER TO SHEETS E-001 AND E-002 FOR ADDITIONAL INFORMATION. B ALL PRODUTS TO BE HANDLED, STORED, AND INSTALLED PER MANUFACTURER REQUIREMENTS. C COMPLY WITH ALL APPLICABLE CODES AND REGULATIONS PERTAINING TO THIS SCOPE OF WORK. OVERALL BUILDING PLAN NOTES # NOTES 1/16" = 1'-0" 2A OVERALL FIRST FLOOR PLAN # Revision Date 145 225 355 550 675 830 1020 480 VOLT 230 20A-2P 30A-2P 385 590 925 1435 1755 2165 2650 N/A 255 390 615 955 1170 1440 1765 CONDUCTOR SIZE THREE PHASE #12 #8 #6 #4 #3 #2 #1 BRANCH CIRCUIT BREAKER SIZE #10 208 VOLT 115 20A-3P 30A-3P 190 295 460 715 880 1080 1325 N/A 125 195 305 475 585 720 880 480 VOLT 270 20A-3P 30A-3P 445 680 1070 1655 2030 2500 3060 N/A 295 455 710 1105 1350 1665 2040 NOTES: 1. MAINTAIN A MAXIMUM VOLTAGE DROP OF 3%. ADJUST CONDUCTOR SIZE PER MAXIMUM BRANCH CIRCUIT LENGTH. 2. BRANCH CIRCUIT LENGTHS ARE BASED ON CONDUCTOR DISTANCE FROM PANELBOARD TO LOAD. 3. PROVIDE JUNCTION BOX TO MAKE WIRE TRANSITION FOR FINAL TERMINATION ON DEVICE, FIXTURE, EQUIPMENT, ETC. 4. CALCULATIONS BASED ON COPPER CONDUCTORS, 80% LOADING OF BRANCH CIRCUIT BREAKER, AND 0.95 POWER FACTOR. F20 12 12 3/4" 1P,1N,1G 2P,1G 2P,1N,1G 3P,1G 3P,1N,1G 3P,1N EQUIP/SERV GROUND FEEDER/BRANCH CIRCUIT LABEL CONDUCTOR SIZE PER CONDUIT CONDUIT SIZE & QUANTITY FEEDER & BRANCH CIRCUIT SCHEDULE (COPPER) 3P,2N,1G 3P,3N,1G 3P,1N,2G PHASE & NEUTRAL 3/4" 3/4" 3/4" 3/4" 3/4" F30 10 10 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" F40 8 10 3/4" 3/4" 1" 1" 1" 1" F50 6 10 1" 1" 1" 1-1/4" 1-1/4" 1" F60 4 10 1" 1" 1-1/4" 1-1/4" 1-1/4" 1-1/4" F70 4 8 1" 1-1/4" 1-1/4" 1-1/4" 1-1/2" 1-1/4" F80 3 8 1" 1-1/4" 1-1/4" 1-1/2" 1-1/2" 1-1/4" F90 2 8 1" 1-1/4" 1-1/2" 1-1/2 " 2" 1-1/2" F100 1 8 1-1/4" 1-1/2" 1-1/2" 2" 2" 2" F110 1 6 1-1/4" 1-1/2" 2" 2" 2-1/2" 2" F125 1/0 6 1-1/4" 1-1/2" 2" 2" 2-1/2" 2" F150 1/0 6 1-1/4" 1-1/2" 2" 2" 2-1/2" 2" F175 2/0 6 1-1/2" 2" 2" 2-1/2" 2-1/2" 2" F200 3/0 6 1-1/2" 2" 2" 2-1/2" 3" 2-1/2" F225 4/0 4 2" 2" 2-1/2" 3" 2-1/2" F250 250 4 2" 2-1/2" 3" 3" 3" F300 350 4 2" 2-1/2" 3" 3-1/2" 3" F350 500 3 2-1/2" 3" 3-1/2" 4" 3-1/2" F400 3/0 3 (2) 1-1/2" (2) 2" (2) 2-1/2" (2) 2-1/2" (2) 2-1/2" F450 4/0 2 (2) 2" (2) 2" (2) 2-1/2" (2) 3" (2) 2-1/2" F500 250 2 (2) 2" (2) 2-1/2" (2) 3" (2) 3" (2) 3" F600 350 1 (2) 2-1/2" (2) 3" (2) 3" (2) 3-1/2" (2) 3" F700 500 1/0 (2) 2-1/2" (2) 3" (2) 3-1/2" (2) 4" (2) 3-1/2" F800 350 2/0 (3) 2-1/2" (3) 3" (3) 3" (3) 3-1/2" (3) 3" F900 350 2/0 (3) 2-1/2" (3) 3" (3) 3" (3) 3-1/2" F1000 500 2/0 (3) 2-1/2" (3) 3" (3) 3-1/2" (3) 4" F1200 350 3/0 (4) 2-1/2" (4) 3" (4) 3" (4) 3-1/2" F1600 500 4/0 (5) 3" (5) 3" (5) 3-1/2" (5) 4" F2000 500 250 (6) 3" (6) 3" (6) 3-1/2" (6) 4" F2500 500 350 (7) 4" (7) 3-1/2" (7) 3-1/2" (7) 4" F3000 500 500 (8) 4" (8) 4" (8) 4" N 6 5 4 3 2 1 A B C D E 6 5 4 3 2 1 A B C D E Project No. Project Date Produced These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect. KEY PLAN B A 5/22/2023 10:17:07 AM C:\_RevitLocal\2023-067.POR_Bldg001_E_2023\2023-067.POR_Bldg001_E_2023_smathis.rvt 2023-067.POR 05.22.2023 GENERAL INFORMATION E-002 SACM JNS Coram Deo Academy Phase One Renovations 2023-067.POR_Coram Deo Academy_Phase One Renovations_ 525 Congressional Blvd, Carmel, IN 46032 E-002_ GENERAL INFORMATION GENERAL FEEDER & BRANCH CIRCUIT SCHEDULE NOTES (COPPER & ALUMINUM) # NOTES A PROVIDE BOTH NEW CONDUCTORS AND NEW CONDUIT FOR ALL FEEDERS AND BRANCH CIRCUITS INDICATED WITH A 'FEEDER/BRANCH CIRCUIT LABEL'. DO NOT REUSE ANY EXISTING CONDUCTORS AND/OR CONDUIT UNLESS SPECIFICALLY NOTED ON DRAWINGS, ONE-LINE DIAGRAM, ETC. B REFER TO SPECIFICATIONS FOR MINIMUM CONDUCTOR AND CONDUIT SIZES. C REFER TO SPECIFICATIONS FOR TYPE OF RACEWAY. D FOR ALL NEW AND EXISTING CONDUIT INSTALLATIONS, REFER TO THE NEC FOR CONDUIT AND TUBING FILL TABLES. IN LOCATIONS WHERE EXISTING CONDUIT IS PERMITTED TO BE REUSED, IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE EXISTING CONDUIT SIZE MEETS THE NEC CONDUIT AND FILL TABLES PRIOR TO BID. IF THE CONDUIT DOES NOT MEET THE NEC FILL TABLES, REPLACE THE CONDUIT FOR THE FEEDER AND/OR BRANCH CIRCUIT IN IT'S ENTIRETY TO SATISFY THE NEC CONDUIT AND TUBING FILL TABLES. E ANY CONDUIT AND/OR CONDUCTOR SIZE DEVIATIONS FROM THIS SCHEDULE, OR INDICATED ON DRAWINGS, MUST BE APPROVED BY THE ENGINEER IN WRITING. GENERAL REQUIREMENTS NOTES (ALL DRAWINGS) # NOTES A APPLICABLE CODES: - 2009 INDIANA ELECTRICAL CODE (2008 NEC WITH AMMENDMENTS) - NFPA 72 - 2010 B CONNECT ALL LIGHTING FIXTURES WITHIN ROOM TO INDICATED SWITCH AND BRANCH CIRCUIT, U.O.N. C WHERE MULTIPLE SWITCHES, RECEPTACLES, AND OTHER OUTLETS (EXCEPT PHONES) ARE INDICATED, PROVIDE MULTI-GANGEBACK OUTLET BOXES WITH GANG BARRIERS AND A COMMON FACEPLATE FOR SIMILIAR DEVICES. D WHERE EXIT SIGNS ARE INDICATED ABOVE DOOR, MOUNT AS FOLLOWS: IF THE DISTANCE BETWEEN THE TOP OF THE DOOR FRAME AND THE CEILING IS 24 INCHES OR LESS, CENTER THE EXIT SIGN BETWEEN TOP OF DOOR FRAME AND CEILING. OTHERWISE, MOUNT BOTTOM OF EXIT SIGN 6 INCHES ABOVE TOP OF DOOR FRAME. MOUNT OTHER WALL MOUNTED EXIT SIGNS LOCATED WITHIN THE SAME AREA AT THE SAME HEIGHT. E WHERE DIFFERENT RECESSED ELECTRICAL DEVICES WITH THE SAME MOUNTING HEIGHTS ARE INDICATED SIDE-BY-SIDE, MOUNT THE DEVICES SO THAT THERE IS FOUR INCHES BETWEEN ADJACENT VERTICAL EDGES. F WHERE ELECTRICAL DEVICES WITH DIFFERENT MOUNTING HEIGHTS ARE LOCATED IN THE SAME AREA ALIGN DEVICES VERTICALLY THROUGH THEIR CENTERLINES. G INSTALL SEPARATE INDEPENDENT NEUTRAL CONDUCTORS FOR ALL 120V AND 277V CIRCUITS. DO NOT SHARE NEUTRALS. H ALL EXIT FIXTURES AND FIXTURES INDICATED WITH "NL" SHALL BE UNSWITCHED. I INSTALL NO MORE THAN THREE PHASE CONDUCTORS (PLUS NEUTRALS AND GROUND) PER CONDUIT UNLESS T310-15 NEC IS FOLLOWED. J NUMBER OF WIRES INDICATED ON DRAWINGS, IN PANEL SCHEDULES AND CIRCUIT SIZING SCHEDULES APPLIES TO CURRENT CARRYING CONDUCTORS INCLUDING NEUTRALS. IN ADDITION TO THE NUMBER OF WIRES INDICATED, PROVIDE AN EQUIPMENT GROUNDING CONDUCTOR SIZED AS SCHEDULED OR SIZED BY NEC 250. K UNLESS OTHERWISE NOTED, PROVIDE FEEDERS AND BRANCH CIRCUITS WHICH HAVE AN AMPACITY EQUAL TO OR GREATER THAN THE CIRCUIT OVERCURRENT PROTECTIVE DEVICE RATING SERVING THE CIRCUIT. REFER TO CIRCUIT SIZING SCHEDULE FOR SIZES OF FEEDERS AND BRANCH CIRCUITS. L COORDINATE LOCATION OF CEILING MOUNTED FIRE ALARM DEVICES WITH OTHER EQUIPMENT TO AVOID INTERFERENCE. LOCATE FIRE ALARM DEVICES AS NEAR TO LOCATION INDICATED WHILE AVOIDING INTERFERENCES. M MAKE FINAL CONNECTION BETWEEN DISCONNECT AND EQUIPMENT BEING SERVED BY FEEDER OR BRANCH CURRENT. N DIVISION 26 CONTRACTOR SHALL REFER TO LIFE SAFETY PLAN FOR FIRE-RATING REQUIREMENTS. DIVISION 26 CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING FIRE-RATED DEVICES/SEALS AS SHOWN ON ELECTRICAL DRAWINGS AND AS REQUIRED BASED ON LIFE SAFETY PLAN INFORMATION. O PER NEC ARTICLE 110.26(A) AND 110.26(F) THE DEDICATED ELECTRICAL SPACE INCLUDES THE SPACE DEFINED BY EXTENDING THE FOOTPRINT OF THE ELECTRICAL EQUIPMENT (INCLUDING BUT NOT LIMITED TO SWITCHBOARDS, PANELBOARDS, TRANSFORMERS, MOTOR CONTROLLERS) FROM THE FLOOR TO A HEIGHT OF 6’-0” ABOVE THE HEIGHT OF THE EQUIPMENT OR TO THE STRUCTURAL CEILING, WHICH EVER IS LOWER. THE DEDICATED ELECTRICAL SPACE MUST BE CLEAR OF ANY PIPING, DUCTS, LEAK PROTECTION APPARATUS, OR EQUIPMENT FOREIGN TO THE ELECTRICAL INSTALLATION. PLUMBING, HEATING, VENTILATION, AND AIR-CONDITIONING PIPING, DUCTS, AND EQUIPMENT MUST BE INSTALLED OUTSIDE THE WIDTH AND DEPTH ZONE. CONTRACTOR SHALL MAKE SURE NO PIPING OR DUCT WORK IS INSTALLED ABOVE THE ELECTRICAL EQUIPMENT. COORDINATE THESE REQUIREMENTS WITH ALL OTHER TRADES PRIOR TO INSTALLATION. P CONTRACT DOCUMENTS CONSISTS OF BOTH A PROJECT MANUAL AND DRAWINGS. BOTH ARE MEANT TO BE COMPLEMENTARY - ANYTHING APPEARING ON EITHER MUST BE EXECUTED THE SAME AS IF SHOWN ON BOTH. # Revision Date • EMERGENCY POWER OFF BUTTON • SIMPLEX RECEPTACLE • NEMA 5-20R, 125V, 20A WIRING DEVICES SUBSCRIPTS FOR RECEPTACLES, JUNCTION BOXES AND OTHER DEVICES INDICATE THE FOLLOWING, U.O.N: F - FLUSH IN FLOOR GFCI - GROUND FAULT CIRCUIT INTERRUPTER H - HORIZONTALLY MOUNTED IG - ISOLATED GROUND L - LOCKING TYPE TR - TAMPER RESISTANT S - SURFACE MOUNTED WP - WEATHERPROOF IN-USE X - MOUNTED IN EXISTING OUTLET BOX • DUPLEX RECEPTACLE • NEMA 5-20R,125V, 20A • DOUBLE DUPLEX (QUADRAPLEX) RECEPTACLE • NEMA 5-20R,125V, 20A • DUPLEX RECEPTACLE • EMERGENCY CIRCUIT • NEMA 5-20R, 125V, 20A • DOUBLE DUPLEX (QUADRAPLEX) RECEPTACLE • EMERGENCY CIRCUIT • NEMA 5-20R, 125V, 20A • SPECIAL RECEPTACLE • NEMA CONFIGURATION AS INDICATED ON DRAWING • JUNCTION BOX • DIRECT CONNECTION TO EQUIPMENT • PULLBOX • PROVIDE PULLBOXES INDICATED AS A MINIMUM • PROVIDE ADDITIONAL PULLBOXES, SIZED PER NEC, AS REQUIRED • FLUSH JUNCTION BOX WITH FURNITURE FEED ADAPTING CONNECTOR MOUNTED AT 6" A.F.F. • SURFACE-MOUNTED RACEWAY • RECEPTACLES IN LOCATIONS INDICATED • WIREWAY • WALL MOUNTED U.O.N. • FLOOR BOX • SINGLE POLE SWITCH • THREE-WAY SWITCH • THREE-WAY SWITCH WITH PILOT LIGHT • FOUR-WAY SWITCH • SINGLE POLE SWITCH W/ PILOT LIGHT • KEY OPERATED SINGLE POLE SWITCH • KEY OPERATED THREE-WAY SWITCH M EMH ATS J J FB M J MS-# • PUSH BUTTON CONTROL STATION PB 3 P 4 3P K 3K MCB D PANELBOARD NAMING 1 2 A 1 BRANCH PANELBOARDS SEQUENTIAL PANEL NUMBER FLOOR PLAN UNIT A - UNIT A B - UNIT B VOLTAGE 2 - 208Y/120V 4 - 480Y/277V FLOOR NUMBER B - BASEMENT 1 - 1ST FLOOR 2 - 2ND FLOOR 1 2 A DP 1 POWER DISTRIBUTION PANELBOARDS SEQUENTIAL PANEL NUMBER "DISTRIBUTION PANELBOARD" FLOOR PLAN UNIT A - UNIT A B - UNIT B VOLTAGE 2 - 208Y/120V 4 - 480Y/277V FLOOR NUMBER B - BASEMENT 1 - 1ST FLOOR 2 - 2ND FLOOR LIGHTING CONTROL DEVICES OS1 O1 • MANUAL CONTROLS & AUTO-ON / AUTO-OFF • 1000 SQFT COVERAGE • TWO RELAYS IN POWER PACK SYMBOL MOUNTING WALL DIMMING TYPE 0-10V OCCUPANCY SENSOR TYPE SWITCH/ BUTTONS CONTROL DESCRIPTION • (1) MANUAL SWITCH ON (TO SELECTED LIGHT LEVEL)/OFF • (1) MANUAL LIGHT LEVEL WITH SLIDER N/A (1) D DS WALL 0-10V • (1) MANUAL SWITCH ON (TO SELECTED LIGHT LEVEL)/OFF • (1) MANUAL LIGHT LEVEL WITH SLIDER • MANUAL ON / AUTO OFF DUAL TECH. (1) D DL WALL LINE VOLT. • (1) MANUAL SWITCH ON (TO SELECTED LIGHT LEVEL)/OFF • (1) MANUAL LIGHT LEVEL WITH SLIDER N/A (1) WALL N/A DUAL TECH. (1) OS2 WALL N/A DUAL TECH. (1) • (1) MANUAL SWITCH ON/OFF • MANUAL ON / AUTO OFF OS3 WALL N/A DUAL TECH. (2) • (2) MANUAL SWITCH ON/OFF • MANUAL ON / AUTO OFF CEILING N/A DUAL TECH. N/A O1 • AUTO-ON / AUTO-OFF ONLY • 1000 SQFT COVERAGE • TWO RELAYS IN POWER PACK CEILING N/A DUAL TECH. N/A O1 • MANUAL CONTROLS & AUTO-ON / AUTO-OFF • 1000 SQFT COVERAGE • TWO RELAYS IN POWER PACK • PLUG-LOAD CONTROL OF RECEPTACLES INDICATED IN ROOM, U.O.N. CEILING N/A DUAL TECH. N/A D DMX WALL DMX N/A MULTI. • DMX COLOR CHANGING CONTROLLER • NICOLAUDIE STICK-CU4 O1 • MANUAL CONTROLS & AUTO-ON / AUTO-OFF • TWO RELAYS IN POWER PACK • HIGHBAY COVERAGE CEILING N/A PIR N/A • (1) MANUAL SWITCH ON/OFF • AUTO ON / AUTO OFF O1 CEILING N/A N/A N/A • DAY-LIGHT HARVESTING CONTROLLER W/AUTO DIMMING A AMPERE ALTERNATING CURRENT; ARMORED CABLE AMP SIZE OF CIRCUIT BREAKER FRAME/FUSED SWITCH ABOVE FINISHED COUNTERTOP ARC FAULT CIRCUIT INTERRUPTER ABOVE FINISHED FLOOR ABOVE FINISHED GRADE AIR HANDLING UNIT AMPERE INTERRUPTING CAPACITY ALUMINUM AMERICAN NATIONAL STANDARDS INSTITUTE ASYMMETRICAL AMP TRIP SIZE CIRCUIT BREAKER/FUSED SWITCH AUTOMATIC TRANSFER SWITCH AUXILIARY AVERAGE AMERICAN WIRE GAUGE BATTERY BRANCH CIRCUIT PANELBOARD BREAKER BOLTED PRESSURE SWITCH CONDUIT; CELSIUS CABINET CIRCUIT BREAKER CENTER TO CENTER CANDELA CUBIC FEET CENTERLINE CEILING CONCRETE MASONRY UNIT COLUMN COMBINATION CONCRETE CONDUCTOR CONNECTION CONTINUOUS; CONTINUED CONSTRUCTION CONTROL PANEL CONTROL POWER TRANSFORMER CURRENT TRANSFORMER COPPER; CONDENSING UNIT CABINET UNIT HEATER CYLINDER DEEP; DEPTH DIRECT BURIED DIRECT CURRENT DEDICATED DEVICE ON INDIVIDUAL BRANCH CIRCUIT DEMOLISH; DEMOLITION DIAMETER DIAGONAL DISCONNECT DISTRIBUTION DOWN DOUBLE-POLE, DOUBLE-THROW DOUBLE-POLE, SINGLE-THROW DISHWASHER DRAWING EACH ELECTRICAL CONTRACTOR; DIVISIONS 26-28 EXHAUST FAN ELECTRICAL GROUND BAR ELECTRICAL GROUNDING CONDUCTOR ELECTRIC HAND DRYER ELECTRICAL ELEVATOR; ELEVATION EMERGENCY ELECTRICAL METALLIC TUBING ENCLOSURE ENGINE ELECTRICALLY OPERATED EMERGENCY POWER OFF EQUAL EQUIPMENT ENERGY REDUCTION MAINTENANCE SWITCH ESTIMATED EXISTING TO REMAIN ELECTRIC WATER COOLER ELECTRIC WATER HEATER EXPOSED EXISTING EXTERIOR FUSED; FAHRENHEIT FIRE ALARM FIRE ALARM ANNUNCIATOR FIRE ALARM CONTROL UNIT FLOOR BOX FOOT-CANDLE FAN COIL UNIT FUSED DISCONNECT FOUNDATION FEEDER FINISHED FIXTURE FULL LOAD AMPS FLEXIBLE FLOOR FACTORY MUTUAL FLEXIBLE METAL CONDUIT FAN POWERED BOX FEED THROUGH LUGS FEET; FOOT FEED THROUGH LUGS FURNISHED FULL VOLTAGE NON-REVERSING GROUND GAUGE GALVANIZED GENERAL CONTRACTOR GARBAGE DISPOSAL GENERATOR GROUND FAULT EQUIPMENT PROTECTION GROUND FAULT CIRCUIT INTERRUPTER HIGH HEAVY DUTY HIGH-DENSITY POLYETHYLENE CONDUIT HAND-OFF-AUTO HORIZONTAL HORSEPOWER HR HT HEAT PUMP HEATER HERTZ INSIDE DIAMETER INSTIT. OF ELECTRICAL AND ELECTRONICS ENGINEERS ISOLATED GROUND INTERMEDIATE METAL CONDUIT IMPEDANCE AC AF AFC AFCI AFF AFG AHU AIC AL ANSI ASYM AT ATS AUX AVG AWG BATT BCP BKR BPS C CAB CB C/C CD CF CL CLG CMU COL COMB CONC COND CONN CONT CONST CP CPT CT CU CUH CYL D DB DC DED DEMO DIA DIAG DISC DISTR DN DPDT DPST DW DWG EA EC EF EGB EGC EHD ELEC ELEV EM EMT ENCL ENG EO EPO EQ EQUIP ERM EST ETR EWC EWH EXP EX EXT F FA FAA FACU FB FC FCU FD FDN FDR FIN FIXT FLA FLEX FLR FM FMC FPB FTL FT FTL FURN FVNR G/GND GA GALV GC GD GEN GFEP GFCI H HD HDPE HOA HORIZ HP HR HT HTP HTR HZ ID IEEE IG IMC IMP ABBREVIATIONS IN INCH INSULATED; INSULATION INTERIOR; INTERNAL INVERTED ELEVATION JOULE JUNCTION BOX THOUSAND THOUSAND CIRCULAR MILS KIRK KEY KNOCKOUT KEYPAD KILOVOLTS KILOVOLT-AMPERES KILOVOLT-AMPERES REACTIVE KILOWATTS LINEAR FEET LENGTH; LONG LIGHTNING ARRESTOR LIGHT EMITTING DIODE LIQUIDTIGHT FLEXIBLE METAL CONDUIT LUMEN LOCK-OUT TAG-OUT LOCKED ROTOR AMPS LONG-SHORT-INSTANTANEOUS LONG-SHORT-INSTANTANEOUS-GROUND FAULT LIGHT; LIQUIDTIGHT LIGHTING LOW VOLTAGE MANUAL MATERIAL MAXIMUM MECH. CONTRACTOR (DIV. 23); METAL CLAD CABLE MINIMUM CIRCUIT AMPACITY MAIN CIRCUIT BREAKER MOTOR CONTROL CENTER MOLDED CASE CIRCUIT BREAKER MAIN DISTRIBUTION PANELBOARD MECHANICAL MANUFACTURING MANUFACTURER MANHOLE; MOUNTING HEIGHT MINIMUM MISCELLANEOUS MAIN LUGS ONLY MAXIMUM OVERCURRENT PROTECTION MAIN SWITCHBOARD MOUNTED MOUNTING MANUAL TRANSFER SWITCH MEDIUM VOLTAGE MEGAVOLT AMPERES MEGAVOLT AMPERES REACTIVE NEUTRAL NOT APPLICABLE NORMALLY CLOSED NEGATIVE (-) NATIONAL ELECTRICAL MANUFACTURERS ASSOC. NON-FUSED DISCONNECT SWITCH NIGHT LIGHT NON-METALLIC SHEATHED CABLE NORMALLY OPEN; NUMBER NOT TO SCALE INSUL INT INV EL J JB K KCMIL KK KO KP KV KVA KVAR KW LF L LA LED LFMC LM LOTO LRA LSI LSIG LT LTG LV MAN MAT MAX MC MCA MCB MCC MCCB MDP MECH MFG MFR MH MIN MISC MLO MOCP MSB MTD MTG MTS MV MVA MVAR N N/A NC NEG NEMA NF NIC NL NM NO NTS KWHR KILOWATT-HOURS LB POUND LCP LIGHTING CONTROL RELAY PANEL MED MEDIUM MW MEGAWATTS; MICROWAVE OVEN MEGB MAIN ELECTRICAL GROUND BAR NOT IN CONTRACT OC OD OH OL P PB PC PED PF PH/Ø PL POS PRI PSF PSI PT PUH PVC PWR QTY R REF REFR REQ'D RLA RMC RM RT RTU RVAT SCCR SCHED SCR SEC SF SFB SFL SN SP SPDT SPEC SPST SQ SQ FT SQ IN SS S/S ST STD STP SURF SW SWBD PIV RECEPT SPD SQ YD SYM T TB TCC TCP TR TS TYP UC UG UL UNFIN UNO VERT UTP UV VAR VFD VG VIF VM VP VR VUV W W/ W/O WG WP WT XFER XFMR Y UTIL V VA TC TD OVERCURRENT OUTSIDE DIAMETER OVERHEAD OVERLOAD POLE PULL BOX; PUSH BUTTON PHOTOCELL; PLUMBING CONTRACTOR (DIVISION 22) PEDESTAL POWER FACTOR PHASE PILOT LIGHT POSITIVE (+) PRIMARY POUNDS PER SQUARE FOOT POUNDS PER SQUARE INCH POTENTIAL TRANSFORMER PROPELLER UNIT HEATER POLYVINYL CHLORIDE CONDUIT POWER QUANTITY RESISTANCE REFERENCE REFRIGERATOR REQUIRED RUNNING LOAD AMPS RIGID METAL CONDUIT ROOM RAINTIGHT ROOF TOP UNIT REDUCED VOLTAGE AUTOTRANSFORMER SHORT-CIRCUIT CURRENT RATING SCHEDULE SHORT CIRCUIT RATING SECONDARY SUPPLY FAN SUB-FEED CIRCUIT BREAKER SUB-FEED LUGS SOLID NEUTRAL SINGLE-POLE SINGLE-POLE, DOUBLE-THROW SPECIFICATION SINGLE-POLE, SINGLE-THROW SQUARE SQUARE FEET SQUARE INCH STAINLESS STEEL START-STOP SHUNT TRIP STANDARD SHIELDED TWISTED PAIR SURFACE SWITCH SWITCHBOARD POST INDICATOR VALVE RECEPTACLE SURGE PROTECTION DEVICE SQUARE YARD SYMMETRICAL TEMPERATURE; TRANSFORMER TERMINAL BLOCK TEMPERATURE CONTROL CONTRACTOR TEMPERATURE CONTROL PANEL TAMPER-RESISTANT TAMPER SWITCH TYPICAL UNDERCOUNTER; UNDERCABINET UNDERGROUND UNDERWRITERS LABORATORY UNFINISHED UNLESS NOTED OTHERWISE VERTICAL UNSHIELDED TWISTED PAIR UNIT VENTILATOR VOLT AMPERES REACTIVE VARIABLE FREQUENCY DRIVE VANDAL GUARD VERIFY IN FIELD VENDING MACHINE VANDAL PROOF VANDAL RESISTANT VERTICAL UNIT VENTILATOR WIDE; WIRE; WATT WITH WITHOUT WIRE GUARD WEATHERPROOF WATERTIGHT; WEIGHT TRANSFER TRANSFORMER WYE UTILITY VOLT VOLT AMPERES TIME CLOCK TIME DELAY • DUPLEX RECEPTACLE • SPLIT-WIRE • NEMA 5-20R, 125V, 20A • DUPLEX RECEPTACLE • PLUG-LOAD CONTROLLED • NEMA 5-20R, 125V, 20A • DOUBLE DUPLEX (QUADRAPLEX) RECEPTACLE • PLUG-LOAD CONTROLLED • NEMA 5-20R, 125V, 20A HALF CONTROLLED FULLY CONTROLLED CONDUIT & FEEDER • OVERHEAD ELECTRICAL SERVICE • UNDERGROUND ELECTRICAL SERVICE • CONDUIT - TURNED UP • CONDUIT - TURNED DOWN • HOMERUN TO PANEL WITH CIRCUIT NUMBER(S) AS INDICATED • GROUND CONDUCTOR • PHASE CONDUCTOR • NEUTRAL CONDUCTOR • ONE-LINE DIAGRAM • EXISTING FEEDER & CONDUIT • ONE-LINE DIAGRAM • DEMOLISHED FEEDER & CONDUIT • ONE-LINE DIAGRAM • NEW (NORMAL) FEEDER & CONDUIT • ONE-LINE DIAGRAM • NEW (EMERGENCY) FEEDER & CONDUIT • ONE-LINE DIAGRAM & FLOOR PLANS • NEW FEEDER & CONDUIT SIZE • REFER TO 'FEEDER & BRANCH CIRCUIT SCHEDULE (COPPER)' OR 'FEEDER SCHEDULE (ALUMINUM)' BASED ON SPECIFICATIONS AND PROVIDE BOTH FEEDER AND CONDUIT SIZE INDICATED F### • FIRE ALARM CONTROL UNIT • FLUSH / SURFACE FIRE ALARM SYSTEM SUBSCRIPTS FOR FIRE ALARM SYSTEM DEVICES INDICATE THE FOLLOWING, U.O.N: S - SURFACE MOUNTED WP - WEATHERPROOF X - MOUNTED IN EXISTING OUTLET BOX • REMOTE FIRE ALARM CONTROL UNIT • FLUSH / SURFACE • FIRE ALARM ANNUNCIATOR UNIT • FLUSH / SURFACE • MANUAL PULL STATION • SPEAKER • WALL / CEILING • VISUAL STROBE • WALL / CEILING • BELL WITH VISUAL INDICATOR • WALL • DUCT DETECTOR - SUPPLY DUCT • DUCT DETECTOR - RETURN DUCT • DOOR HOLD RELEASE DEVICE • SUPPLIED BY DIVISION 8 • SPRINKLER SYSTEM TAMPER SWITCH • SPRINKLER SYSTEM FLOW SWITCH • POST INDICATOR VALVE • SPEAKER/STROBE • WALL / CEILING • HORN • WALL / CEILING M S S H H V B R TS FS P S F R F S D R D FACU FACU RACU RACU FAA FAA AR • ADDRESSABLE RELAY MODULE FOR CONTROL / MONITORING • SPRINKLER SYSTEM PRESSURE SWITCH PS • HORN/STROBE • WALL / CEILING • SMOKE DETECTOR • CEILING • HEAT DETECTOR • CEILING SR F • COMBINATION SMOKE / HEAT DETECTOR • CEILING V V V V V • POWER DISTRIBUTION PANELBOARD • 480Y / 277V; 3Ø, 4W • FLOOR / SURFACE HALF CONTROLLED FULLY CONTROLLED SYMBOL MOUNTING HEIGHT ABOVE FINISHED FLOOR (U.O.N.) • +18" TO CENTER OF RECEPTACLE • +6" ABOVE TOP OF COUNTERTOP TO BOTTOM OF RECEPTACLE SO1, SO2, SO3, • +46" TO CENTER OF LIGHT SWITCH / CONTROLS 3, 4, P, 3P, K, 3K D D1, D2, D3, DMX • +46" TO CENTER OF DIMMER / CONTROLS • COORDINATE MOUNTING HEIGHT WITH EQUIPMENT IF NOT INDICATED ON DRAWING MSSWITCH • +46" TO CENTER OF MOTOR STARTER TOGGLE • +46" TO CENTER OF EMERGENCY SHUT-OFF B H H S S V • +80" TO BOTTOM OF WALL MOUNTED FIRE ALARM DEVICE M • +46" TO CENTER OF MANUAL PULL STATION • REFER TO SPECIFICATIONS AND 'GENERAL SYMBOLS & ABBREVIATIONS NOTES (ALL DRAWINGS)' • +90" TO TOP OF POWER DISTRIBUTION PANELBOARD'S TRIM • +72" TO TOP OF PANELBOARD'S TRIM • +72" TO TOP OF EQUIPMENT • +72" TO TOP OF EQUIPMENT • +18" TO CENTER OF RECEPTACLE • +6" ABOVE TOP OF COUNTERTOP TO BOTTOM OF RECEPTACLE • FLUSH TO CEILING MOUNTING HEIGHTS ANNOTATION SYMBOLS • CIRCUIT TAG PANEL-CKT • ROOM CIRCUIT TAG PANEL-CKT FSSWITCH FLOW MFSSWITCH MAIN FUSED N 6 5 4 3 2 1 A B C D E 6 5 4 3 2 1 A B C D E Project No. Project Date Produced These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect. KEY PLAN B A 5/22/2023 10:16:41 AM C:\_RevitLocal\2023-067.POR_Bldg001_E_2023\2023-067.POR_Bldg001_E_2023_smathis.rvt 2023-067.POR 05.22.2023 SYMBOLS & ABBREVIATIONS E-001 SACM JNS Coram Deo Academy Phase One Renovations 2023-067.POR_Coram Deo Academy_Phase One Renovations_ 525 Congressional Blvd, Carmel, IN 46032 E-001_ SYMBOLS & ABBREVIATIONS GENERAL ROUGH-IN MOUNTING HEIGHT NOTES # NOTES A COMPLETE COMPLIANCE WITH ALL ASPECTS OF ADA STANDARDS FOR ACCESSIBLE DESIGN AND ICC/ANSI A117.1 IS REQUIRED OF ALL PROJECTS AND ACTIVITIES. B MOUNTING HEIGHTS INDICATED ARE FOR TYPICAL DEVICES, UNLESS NOTED OR SPECIFIED OTHERWISE. C COORDINATE MOUNTING HEIGHTS OF ANY DEVICES WHICH ARE NOT INDICATED BY ARCHITECT OR AND/OR ENGINEER. D REFERENCE DIVISIONS 8, 10, 14, 22, 23, AND 27 FOR ADDITIONAL MOUNTING HEIGHTS. # Revision Date 1/2" CW 1 1/2" TW 1 1/2" TW 1 1/2" TW 1 1/2" TW 1 1/2" TW 1 1/2" TW TMV-1 1 1/2" TW 1 1/4" CW 1 1/4" HW 1 1/2" TW 1/2" CW 1/2" HW 1/2" HW 1/2" CW 1 1/2" TW SK-3 AN-1 SK-2 AN-1 SK-2 AN-1 SK-2 AN-1 SK-2 AN-1 AN-1 EWES-1 FD-1 FCO 2" W 3" W 3" W 3" W 3" W 3" W 2" W 3" W 3" W 2" W 2" W 1 1/2" V 1 1/2" W 1 1/2" AW 1 1/2" AW 1 1/2" V 2" W 1 1/2" V 1 1/2" V 2" V 1 1/2" AW 1 1/2" AW 1 1/2" V 2" V 2" V 2" V 3" V 1 1/2" V 3" VTR 3" V 1 1/2" AW 1 1/2" AW 2" W 2" W 2" W 3" W FCO 2" W 2" W 3" W 3" W 2" W 3" W 1 1/2" V 3" W 3" W 2" W 2" W 2" W 2" W 2" W 2" W 3" W 2" W 3" W 2" W 2" W GPR-1 GSV-1 RPB-1 MGP-1 1/2" G (6 in-wc) 1/2" G (6 in-wc) GT-2 GT-1 1/2" G (6 in-wc) 1/2" G (6 in-wc) 1/2" G (6 in-wc) 1/2" G (6 in-wc) 3/4" G (6 in-wc) 3/4" G (6 in-wc) 1/2" G (6 in-wc) 3/4" G (6 in-wc) PIPE UNION 3/4" G (6 in-wc) 1/2" G (6 in-wc) 1/2" G (6 in-wc) GT-1 GT-1 1/2" G (6 in-wc) GT-1 1/2" G (6 in-wc) 1/2" G (6 in-wc) 1/2" G (6 in-wc) 1/2" G (6 in-wc) 1/2" G (6 in-wc) 1/2" G (6 in-wc) 1/2" G (6 in-wc) 1/2" G (6 in-wc) 1. DISTANCE BETWEEN GENERATOR AND PRESSURE REGULATOR TO BE MIN. 10 PIPE DIAMETERS OR AS DIRECTED BY INSTALLATION MANUAL. NATURAL GAS GENERAL NOTE N 6 5 4 3 2 1 A B C D E 6 5 4 3 2 1 A B C D E Project No. Project Date Produced These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect. KEY PLAN B A 5/22/2023 6:05:10 PM C:\_RevitLocal\2023-067.POR_Bldg001_P_2023\2023-067.POR_Bldg001_P_2023_jbaughman.rvt 2023-067.POR 05.22.2023 PLUMBING ISOMETRIC P-901 Designer JJB Coram Deo Academy Phase One Renovations 2023-067.POR_Coram Deo Academy_Phase One Renovations_ 525 Congressional Blvd, Carmel, IN 46032 P-901_ PLUMBING ISOMETRIC PLUMBING ISOMETRIC PLAN NOTES # NOTE 1 CONNECT TO FUME HOOD PER MANUFACTURERS INSTRUCTIONS. 2 CONNECT TO SHOWER HEAD PER MANUFACTURERS INSTRUCTIONS. 3 CONTRACTOR SHALL COORDINATE WITH FUME HOOD MANUFACTURER TO CONNECT AN-1 TO CUP SINK WASTE PIPING. 1A DOMESTIC WATER PLUMBING ISOMETRIC - ART ROOM 3A DOMESTIC WATER PLUMBING ISOMETRIC - SCIENCE LAB - ALTERNATE 2D SANITARY WASTE AND VENT PLUMBING ISOMETRIC - SCIENCE LAB - ALTERNATE 5D GAS AND AIR PLUMBING ISOMETRIC - SCIENCE LAB - ALTERNATE 1 2 2 1 1 3 PLUMBING FIXTURE ROUGH-IN LEGEND MARK FIXTURE CONNECTION CW HW W V EWES-1 FD-1 3" SK-1 SK-2 1/2" 1/2" 1 1/2" 1 1/2" SK-3 1/2" 1/2" 1 1/2" 1 1/2" PLUMBING FIXTURE ROUGH-IN LEGEND MARK FIXTURE CONNECTION CW HW W V EWES-1 FD-1 3" SK-1 SK-2 1/2" 1/2" 1 1/2" 1 1/2" SK-3 1/2" 1/2" 1 1/2" 1 1/2" # Revision Date 2023-067.POR 05.22.2023 PLUMBING DETAILS AND SCHEDULES P-501 Designer JJB Coram Deo Academy Phase One Renovations 2023-067.POR_Coram Deo Academy_Phase One Renovations_ 525 Congressional Blvd, Carmel, IN 46032 P-501_ PLUMBING DETAILS AND SCHEDULES EMERGENCY PLUMBING FIXTURE SCHEDULE (224500) IDENTITY DATA FIXTURE CONNECTION MARK MANUFACTURER MODEL DESCRIPTION T W V MOUNTING NOTES EWES-1 Guardian Equipment #GBF2360 RECESSED SAFETY STATION WITH DRAIN PAN, SHOWER HEAD, FIRE RATED CONSTRUCTION COMMERCIAL SINK SCHEDULE (224216.16) IDENTITY DATA FAUCET FIXTURE CONNECTION MOUNTING ADA MARK MANUFACTURER MODEL DESCRIPTION MANUFACTURER MODEL CW HW W V COMPLIANT NOTES SK-1 MUSTEE #18F FLOOR MOUNTED UTILITY TUB CHICAGO FAUCETS #786-HR8AE3V317XKAB SK-2 N/A N/A INTEGRAL EPOXY SINK BY INTERIORS CHICAGO FAUCETS #LWM1-A11-F 1/2" 1/2" 1 1/2" 1 1/2" COUNTER MOUNTED No SK-3 N/A N/A INTEGRAL EPOXY SINK BY INTERIORS CHICAGO FAUCETS #LWM1-A13-F 1/2" 1/2" 1 1/2" 1 1/2" COUNTER MOUNTED Yes SANITARY WASTE PIPING SPECIALTIES SCHEDULE (221319) IDENTITY DATA W MARK MANUFACTURER MODEL DESCRIPTION CONNECTION NOTES FD-1 J.R. SMITH #2005YA-U-PB DUCO CAST IRON BODY WITH FLASHING COLLAR, ADJUSTABLE ROUND STRAINER HEAD, POLISHED BRONZE STRAINER 3" TRAPGUARD BY PROSET. NO SUBSTITUTIONS. GAS ACCESSORIES MARK MANUFACTU RER MODEL DESCRIPTION NOTES GSV-1 ISIMET #S-302-VA-111-U GAS SOLENOID VALVE - 24V COIL WIRE TO MASTER GAS CONTROL PANEL MGP-1 ISIMET #LAV2-LV-K-S-G MASTER GAS CONTROL PANEL RPB-1 ISIMET #IP-0 REMOTE PANIC BUTTON WIRE TO MASTER GAS SOLENOID ASSEMBLY GAS PRESSURE REGULATORS MARK DESCRIPTION INLET PRESSURE OUTLET PRESSURE TOTAL CONNECTED LOAD (BTU/H) EQUIPMENT SERVED GPR-1 GAS PRESSURE REGULATOR 2 PSI 6" W.C. 30000 SCIENCE LAB GAS TURRETS MIXING, METERING, AND PRESSURE REDUCING VALVES (221119) IDENTITY DATA MARK MANUFACTURER MODEL DESCRIPTION FLOW RATE PRESSURE DROP NOTES 33 GUARDIAN NRS-13 THERMOSTATIC MIXING VALVE, 50 GALLON CAPACITY GAS TURRETS IDENTITY DATA GAS MARK MANUFACTURER MODEL DESCRIPTION CONNECTION GT-1 CHICAGO FAUCET #LGN1-A11C-10 (1) OUTLET, REMOVABLE SERRATED NOZZLE, INTEGRAL CHECK VALVE, GAS INDICATOR BUTTON, VANDAL RESISTANT VALVE, CHROME PLATED WITH ANTI-ROTATION PIN 1/2" GT-2 CHICAGO FAUCET #LGB1-11C-10 (1) OUTLET, REMOVABLE SERRATED NOZZLE, INTEGRAL CHECK VALVE, GAS INDICATOR BUTTON, VANDAL RESISTANT VALVE, CHROME PLATED WITH ANTI-ROTATION PIN 1/2" 1C 1/8" = 1'-0" PIPE HANGER (6" & SMALLER) DETAIL # Revision Date Coram Deo Academy Phase One Renovations 2023-067.POR_Coram Deo Academy_Phase One Renovations_ 525 Congressional Blvd, Carmel, IN 46032 PR101_ ROOF LEVEL PLUMBING PLAN - ALTERNATE ROOF PLUMBING PLAN NOTES # NOTE 1 2 3 1/8" = 1'-0" 2A ROOF PLUMBING PLANS PLUMBING FIXTURE ROUGH-IN LEGEND MARK FIXTURE CONNECTION CW HW W V EWES-1 FD-1 3" SK-1 SK-2 1/2" 1/2" 1 1/2" 1 1/2" SK-3 1/2" 1/2" 1 1/2" 1 1/2" # Revision Date 3/4" G (6 in-wc) 1" CW 3/4" HW 4 GSV-1 GPR-1 5 1/2" CW 1/2" HW 1 1/2" V 6 3" V 3" V GT-1 SK-2 GT-2 SK-3 2" V GT-1 SK-2 GT-1 SK-2 GT-1 SK-2 FCO EWES-1 MGP-1 RPB-1 1. DISTANCE BETWEEN GENERATOR AND PRESSURE REGULATOR TO BE MIN. 10 PIPE DIAMETERS OR AS DIRECTED BY INSTALLATION MANUAL. NATURAL GAS GENERAL NOTE N 6 5 4 3 2 1 A B C D E 6 5 4 3 2 1 A B C D E Project No. Project Date Produced These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect. KEY PLAN B A 5/22/2023 6:04:32 PM C:\_RevitLocal\2023-067.POR_Bldg001_P_2023\2023-067.POR_Bldg001_P_2023_jbaughman.rvt 2023-067.POR 05.22.2023 LEVEL 1 PLUMBING PLANS - UNIT A - ALTERNATE PP1A2 Designer JJB Coram Deo Academy Phase One Renovations 2023-067.POR_Coram Deo Academy_Phase One Renovations_ 525 Congressional Blvd, Carmel, IN 46032 PP1A2_ LEVEL 1 PLUMBING PLANS - UNIT A - ALTERNATE PLUMBING PLAN NOTES # NOTE 1 EXISTING ROUTING IS PRESUMED. CONTRACTOR TO VERIFY IN FIELD AND CONNECT NEW DOMESTIC HW, CW, AND SANITARY VENT PIPING TO EXISTING OF EQUAL OR LARGER SIZES.PIPE 2 PATCH WALL AND MATCH EXISTING FINISH. 3 EXISTING ROUTING IS PRESUMED. CONTRACTOR TO VERIFY IN FIELD AND CONNECT NEW DOMESTIC HW, CW, HWR, AND GAS PIPING TO EXISTING OF EQUAL OR LARGER SIZES PIPE. 1/8" = 1'-0" 2A LEVEL 1 PLUMBING PLANS - SCIENCE LAB PLUMBING FIXTURE ROUGH-IN LEGEND MARK FIXTURE CONNECTION CW HW W V EWES-1 FD-1 3" SK-1 SK-2 1/2" 1/2" 1 1/2" 1 1/2" SK-3 1/2" 1/2" 1 1/2" 1 1/2" # Revision Date B104 MENS RR A109 WOMENS RR A108 STORAGE A103A RISER RM A108A STORAGE B102 OFFICE A103 CLINIC A101 CORRIDOR A001 OFFICE A102 GYM A110 VESTIBULE A110B CLASSROOM B117 PRACTICE ROOM B117A SK-1 1 1/2" V 1/2" HW 1. EXISTING PIPE ROUTING, AS SHOWN ON DRAWINGS, IS BASED UPON RECORD DOCUMENTS AND FIELD SURVEYS. ACTUAL ROUTE OF CONCEALED PIPING MAY VARY. CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY PIPE ROUTING PRIOR TO SAW CUTTING OF FLOOR SLABS. 2. CONTRACTOR SHALL JET AND THOROUGHLY FLUSH EXISTING SANITARY SEWERS WHERE DOCUMENTS CALL FOR NEW WASTE PIPE CONNECTIONS. 3. ALL UNDERGROUND SANITARY OR STORM PIPING SHOWN TO BE ABANDONED IN PLACE SHALL BE CAPPED AND FILLED WITH FLOWABLE FILL. 4. WHERE PLUMBING FIXTURE ROUGH-IN PIPING IS SHOWN TO BE ABANDONED IN WALLS OR BELOW FLOOR SLAB, ROUGH-INS SHALL BE REMOVED TO A POINT BEYOND THE FINISHED SURFACE AND CAPPED. PATCH SURFACE TO MATCH EXISTING FINISH. 5. IN AREAS WHERE A FULL REMODEL IS INDICATED ON THE DRAWINGS, CONTRACTOR SHALL REMOVE ALL OVERHEAD PIPING AND HANGERS COMPLETE UNLESS OTHERWISE INDICATED. 6. WHERE SANITARY OR ACID VENT THROUGH ROOF IS SHOWN TO BE ABANDONED IN PLACE, CONTRACTOR SHALL PERMANENTLY CAP PIPE ABOVE AND BELOW ROOF FOR A WATER TIGHT SEAL. PLUMBING RENOVATION NOTES N 6 5 4 3 2 1 A B C D E 6 5 4 3 2 1 A B C D E Project No. Project Date Produced These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect. KEY PLAN B A 5/22/2023 6:05:52 PM C:\_RevitLocal\2023-067.POR_Bldg001_P_2023\2023-067.POR_Bldg001_P_2023_jbaughman.rvt 2023-067.POR 05.22.2023 LEVEL 1 PLUMBING PLANS - UNIT A PP1A1 Designer JJB Coram Deo Academy Phase One Renovations 2023-067.POR_Coram Deo Academy_Phase One Renovations_ 525 Congressional Blvd, Carmel, IN 46032 PP1A1_ LEVEL 1 PLUMBING PLANS - UNIT A 1/8" = 1'-0" 2A LEVEL 1 PLUMBING PLANS - ART ROOM PLUMBING PLAN NOTES # NOTE 1 EXISTING ROUTING IS PRESUMED. CONTRACTOR TO VERIFY IN FIELD AND CONNECT NEW DOMESTIC HW, CW, AND SANITARY VENT PIPING TO EXISTING OF EQUAL OR LARGER SIZES.PIPE 2 PATCH WALL AND MATCH EXISTING FINISH. 3 EXISTING ROUTING IS PRESUMED. CONTRACTOR TO VERIFY IN FIELD AND CONNECT NEW DOMESTIC HW, CW, HWR, AND GAS PIPING TO EXISTING OF EQUAL OR LARGER SIZES PIPE. PLUMBING FIXTURE ROUGH-IN LEGEND MARK FIXTURE CONNECTION CW HW W V EWES-1 FD-1 3" SK-1 SK-2 1/2" 1/2" 1 1/2" 1 1/2" SK-3 1/2" 1/2" 1 1/2" 1 1/2" # Revision Date SCIENCE LAB A121 CLASSROOM A120 CORRIDOR A003 OFFICE A115 OFFICE A114 VESTIBULE A003B CLASSROOM A113 CLASSROOM A116 CORRIDOR A003 CORRIDOR A003 STORAGE A112 STORAGE A111 CLASSROOM A118 OFFICE A119 STORAGE A117 GYM A110 STORAGE A110A MENS RR A109 WOMENS RR A108 EX. 4" W EX. 4" W 3" W FD-1 FCO 3" W 3" W 3" W 2" W 2" W 2" W 3" W 3" W 2" W 2" W 3" W 2" W 2" W 3" W 2" W 2" W 3" W 3" W 3" W 3" W FCO 3" W 2" W 2" W 1 2" W 1 1 1 N 6 5 4 3 2 1 A B C D E 6 5 4 3 2 1 A B C D E Project No. Project Date Produced These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect. KEY PLAN B A 5/22/2023 6:04:19 PM C:\_RevitLocal\2023-067.POR_Bldg001_P_2023\2023-067.POR_Bldg001_P_2023_jbaughman.rvt 2023-067.POR 05.22.2023 FOUNDATION PLUMBING PLANS - UNIT A - ALTERNATE PF1A1 Designer JJB Coram Deo Academy Phase One Renovations 2023-067.POR_Coram Deo Academy_Phase One Renovations_ 525 Congressional Blvd, Carmel, IN 46032 PF1A1_ FOUNDATION PLUMBING PLANS - UNIT A - ALTERNATE FOUNDATION PLUMBING PLAN NOTES # NOTE 1 ROUTE PIPING UP INTO UTILITY CHASE BEHINDE CABINETS. 4 INSTALL PIPE SLEEVE AT EACH WALL PENETRATION 2 SIZES LARGER THAN PIPE PASSING THROUGH THE WALL. 5 CONTRACTOR TO ROUTE TO GAS METER AND CONNECT. COORDINATE WITH UTILITY COMPANY TO ENSURE THAT METER IS SIZED APPROPRIATELY AND UPSIZE IF NEEDED TO ACCOMODATE 30,000 BTUH FOR SCIENCE LAB GAS TURRETS. 6 DROP IN WALL AND ROUTE TO SINKS AND TURRETS WITHIN UTILITY CHASE BEHIND THE CABINET BASES. 1/8" = 1'-0" 2A FOUNDATION PLUMBING PLANS PLUMBING FIXTURE ROUGH-IN LEGEND MARK FIXTURE CONNECTION CW HW W V EWES-1 FD-1 3" SK-1 SK-2 1/2" 1/2" 1 1/2" 1 1/2" SK-3 1/2" 1/2" 1 1/2" 1 1/2" # Revision Date 1 B C D E E 10 10 11 11 12 12 H H J K L F F G G A5 A5 A4 A4 A3 A3 A2 A2 A1 A1 E.P E.P N 6 5 4 3 2 1 A B C D E 6 5 4 3 2 1 A B C D E Project No. Project Date Produced These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect. KEY PLAN B A 5/22/2023 6:04:07 PM C:\_RevitLocal\2023-067.POR_Bldg001_P_2023\2023-067.POR_Bldg001_P_2023_jbaughman.rvt 2023-067.POR 05.22.2023 LEVEL 1 FIRE PROTECTION PLUMBING PLAN FP101 Designer JJB Coram Deo Academy Phase One Renovations 2023-067.POR_Coram Deo Academy_Phase One Renovations_ 525 Congressional Blvd, Carmel, IN 46032 FP101_ LEVEL 1 FIRE PROTECTION PLUMBING PLAN 1/16" = 1'-0" 2A LEVEL 1 FIRE PROTECTION PLUMBING PLAN # Revision Date A111 Unoccupied Unoccupied OFFICE A102 WOMENS RR A108 UNOCCUPIED A124 MENS RR A109 OFFICE B107 OFFICE B106 OFFICE B105 WOMENS RR B104 COPIER B109 STORAGE B115C STORAGE B115B RISER RM A108A STORAGE A103A JANITOR A107 OFFICE A105 OFFICE A103 PARENT ROOM B100 SCIENCE LAB A121 UNOCCUPIED A122 UNOCCUPIED A123 BREAK ROOM A106 STORAGE A106A OFFICE A104 CORRIDOR A001 PRACTICE ROOM B117A STORAGE B101 STORAGE B102 CLINIC A101 LOBBY A100 VESTIBULE A003A STORAGE A117 UNOCCUPIED A126 UNOCCUPIED A125 UNOCCUPIED A127 OFFICE A119 CLASSROOM A118 UNOCCUPIED A130 UNOCCUPIED A129 UNOCCUPIED A128 VESTIBULE A003B STORAGE A112 CORRIDOR A003 VESTIBULE A100A MENS RR B103 CORRIDOR A002 STORAGE A110A CLASSROOM B115 CLASSROOM B117 VESTIBULE A110B GYM A110 CLASSROOM A120 RR A110C N 6 5 4 3 2 1 A B C D E 6 5 4 3 2 1 A B C D E Project No. Project Date Produced These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect. KEY PLAN B A 5/22/2023 6:03:51 PM C:\_RevitLocal\2023-067.POR_Bldg001_P_2023\2023-067.POR_Bldg001_P_2023_jbaughman.rvt 2023-067.POR 05.22.2023 LEVEL 1 DEMOLITION PLUMBING PLAN - UNIT A PD1A1 Designer JJB Coram Deo Academy Phase One Renovations 2023-067.POR_Coram Deo Academy_Phase One Renovations_ 525 Congressional Blvd, Carmel, IN 46032 PD1A1_ LEVEL 1 DEMOLITION PLUMBING PLAN - UNIT A DEMOLITION PLAN NOTES # NOTE 1 REMOVE WATER CLOSET AND ROUGH-IN PIPING FOR DOMESTIC WATER AND SANITARY WASTE BACK TO WITHIN CHASE. PROVIDE TEMPORARY CAPS AND PREPARE FOR RECONNECTION. 2A 1/8" = 1'-0" LEVEL 1 DEMOLITION PLUMBING PLANS - ART ROOM # Revision Date FLOOR DRAIN FIRE PROTECTION CONTRACTOR FIRE DEPARTMENT CONNECTION G GAL GA FPC FOV FP FT FPM FTG GALLON GAUGE NATURAL GAS FIRE PROTECTION FUEL OIL VENT FEET PER MINUTE FOOTING FOOT/FEET FE FHC FH FOS FOR FLR FCO FDC FD FIRE EXTINGUISHER FUEL OIL RETURN FUEL OIL SUPPLY FIRE HOSE CABINET FLOOR FIRE HOSE FLOOR CLEANOUT RO RPM RM RECIR RH RD RCP R PVC EXIST EXP °F ET EWC EW DEGREES FAHRENHEIT EXPANSION EXISTING EXPANSION TANK EMERGENCY EYEWASH ELECTRIC WATER COOLER EMER ENCL ES EQUIP EFF ELEV ELEC EMERGENCY EMERGENCY SHOWER EQUIPMENT ENCLOSURE ELEVATION ELECTRIC EFFICIENCY PSIG PRESS PRV PSI PREFAB PPM POC PIV PLT PER PI PH PD PC STORAGE TANK PUMP STORAGE TANK SUPPLY AND RETURN STRUCTURE(E), (AL) SUB SURFACE (FOOTING) DRAIN STORAGE TANK STAINLESS STEEL SERVICE SINK STANDARD SPECIFICATIONS SPECIAL GAS SHEET SINK SOFT COLD WATER (DOMESTIC) SQUARE FOOT SHOWER SECTION SITZ BATH RODDING HOLE REVERSE OSMOSIS WATER REVOLUTIONS PER MINUTE ROOM RECIRCULAT(E), (OR), (ING) REINFORCED CONCRETE PIPE ROOF DRAIN THERMAL RESISTANCE POLYVINYL CHLORIDE POST INDICATOR VALVE POINT OF CONNECTION (NEW TO EXISTING) POUNDS PER SQUARE INCH PRESSURE REDUCING VALVE POUNDS PER SQUARE INCH GAUGE PRESSURE PARTS PER MILLION PREFABRICATED PLASTER TRAP PRESSURE DROP (IN OR WG AS NOTED) PERCENT PRESSURE INDICATOR PHASE PLUMBING CONTRACTOR MISC ECO EC DN DS DF DWG DWH EXTERIOR CLEANOUT ELECTRICAL CONTRACTOR DRINKING FOUNTAIN DOMESTIC WATER HEATER DRAWING DOWNSPOUT DOWN CW D COLD WATER (DOMESTIC) DRAIN P OSD OFOI OFCI OFD OE OA O NA NO NTS NIC NC N MTD CONTRACTOR FURNISHED/OWNER INSTALLED BRITISH THERMAL UNIT PER HOUR CO CI CONN CO2 CFOI CARBON DIOXIDE CONNECTION CAST IRON CLEANOUT BT CD BTUH BOP BLDG BATHTUB CONDENSATE DRAIN BOTTOM OF PIPING BUILDING MIN MH MECH MC MBH MS MB MAX LPC MA LV LFC LP LEC AREA DRAIN AMPERE (AMP, AMPS) A AW BFC AMP ARCH AV APD APPROX COMPRESSED AIR BELOW FINISHED CEILING ACID WASTE AIR PRESSURE DROP (IN WG) ARCHITECT (URAL) APPROXIMAT(E), (LY) ACID VENT ADJ AE AFF ALTER AD ADA ADJUSTABLE ABOVE FINISHED FLOOR ANESTHESIA EVACUATION ALTERNATE AMERICAN DISABILITIES ACT LBS LAB LA L KW INV KEC IN INDIC INSUL INT INCL ID HZ VACUUM PUMP DISCHARGE W/O WITHOUT MISCELLANEOUS OWNER FURNISHED/CONTRACTOR INSTALLED OWNER FURNISHED/OWNER INSTALLED OPEN SITE DRAIN PUMP ORAL EVACUATION OVERFLOW DRAIN OUTSIDE AIR OXYGEN NOT APPLICABLE NORMALLY CLOSED NORMALLY OPEN NOT TO SCALE NOT IN CONTRACT NITROGEN MOUNTED ZN WTR YD WPD WP ZONE WATER PRESSURE DROP YARD DRAIN WEATHERPROOF WATER THOUSANDS OF BTU PER HOUR MECHANICAL MINIMUM MANHOLE MECHANICAL CONTRACTOR MOP SINK MOP BASIN MAXIMUM LABORATORY FURNISHINGS CONTRACTOR LABORATORY PLUMBING CONTRACTOR LABORATORY EQUIPMENT CONTRACTOR LABORATORY VACUUM MEDICAL AIR LIQUID PETROLEUM WH WG W.C. WCO WC W/ VV VPD VT VTR WATER CLOSET WATER COLUMN WALL CLEANOUT WATER GAUGE WALL HYDRANT VITRIFIED TILE VENT THROUGH ROOF VACUUM VENT WITH VB VERT VIF VC VAC VAR VA VACUUM BREAKER VERIFY IN FIELD VACUUM CLEANING VERTICAL VOLT AMPERE VACUUM VARIABLE TEMPERATURE AND PRESSURE THERMOSTATIC MIXING VALVE UNLESS NOTED OTHERWISE INVERT KITCHEN EQUIPMENT CONTRACTOR LABORATORY AIR LABORATORY POUND KILOWATT LAVATORY INCH/INCHES INSULAT(E), (ED), (ION) INCLUD(E), (ED) INDICATOR INTERIOR FREQUENCY (MEGAHERTZ) INSIDE DIAMETER UNO UR TYP. TS TP URINAL TRAP PRIMER TAMPER SWITCH TYPICAL TEMP TMV T&P SU TEMPERATURE SHOWER UNIT ABBREVIATIONS HW HOT WATER (DOMESTIC) T TEMPERED WATER DWS DOMESTIC WATER SOFTNER HOT WATER RECIRCULATING PUMP ABBREVIATIONS 2 M-301 3 M-501 SECTION REFERENCE DETAIL REFERENCE PLAN NOTE DRAWING NOTATIONS NOTE: ALL SYMBOLS AND ABBREVIATIONS MAY NOT BE USED FOR THIS PROJECT DEMO NEW NEW TO EXISTING DEMO TO THIS POINT XXX-1 EQUIPMENT TAG - (SEE SCHEDULE SHEETS) XXX-1 FIXTURE TAG - (SEE SCHEDULE SHEETS) FIRE PROTECTION SYMBOLS A TS F F ALARM VALVE ZONE VALVE (OS&Y) SIDEWALL SPRINKLER HEAD CONCEALED PENDANT SPRINKLER HEAD UPRIGHT SPRINKLER HEAD PENDANT SPRINKLER HEAD DRY PENDANT SPRINKLER HEAD FIRE DEPT. CONNECTION POST INDICATOR VALVE FLOW SWITCH TAMPER SWITCH FIRE WATER MAIN 140° HW 140° HWR 160° HW 160° HWR AV AW AIR CW HW HWR FPD FP FPPA FPW G (11 in-wc) G (2 psig) GW LCW LHR LA LHW LVAC LVE N2 PWR PWS RO ROR SCW SHW ST TW VAC V W 140° DOMESTIC HOT WATER 140° DOMESTIC HOT WATER RETURN 160° DOMESTIC HOT WATER 160° DOMESTIC HOT WATER RETURN ACID RESISTANT VENT ACID RESISTANT WASTE AIR DOMESTIC COLD WATER DOMESTIC HOT WATER DOMESTIC HOT WATER RETURN FIRE PROTECTION DRY FIRE PROTECTION OTHER FIRE PROTECTION PRE-ACTION FIRE PROTECTION WET GAS (11" w.c.) GAS (2 psig) GREASE WASTE LAB AIR LAB COLD WATER LAB HOT WATER LAB HOT WATER RETURN LAB VACUUM LAB VACUUM EXHAUST NITROGEN PURE WATER RETURN PURE WATER SUPPLY REVERSE OSMOSIS WATER REVERSE OSMOSIS WATER RETURN SOFT COLD WATER SOFT HOT WATER STORM TEMPERED WATER VACUUM VENT WASTE PIPING SYSTEMS CA COMBUSTION AIR EA EXHAUST AIR G (6 in-wc) GAS (6" w.c.) G (5 psig) GAS (5 psig) RCW RAW COLD WATER GENERAL DUTY VALVES & FITTINGS A CONCENTRIC REDUCER DOMESTIC COLD WATER VALVE BOX ECCENTRIC REDUCER PRESSURE REDUCING VALVE (P) = PRESSURE VACUUM BREAKER GAS COCK PETE'S PLUG PIPE EXPANSION JOINT FLEXIBLE PIPING CONNECTOR Y-STRAINER W/BLOWDOWN VALVE & CAP PIPE ANCHORS PIPE GUIDES THERMOMETER WELL AUTOMATIC AIR VENT GAUGE CONNECTION(S) & WELL THERMOMETER & WELL MANUAL AIR VENT AUTOMATIC BALANCING VALVE TWO-WAY CONTROL VALVE THREE-WAY CONTROL VALVE UNION MANUAL BALANCING VALVE ANGLE VALVE PLUG VALVE PRESSURE REGULATING VALVE BUTTERFLY VALVE VALVE - SEE SPECIFICATIONS FOR VALVE TYPE PIPE CONTINUED ON ANOTHER DRAWING CHECK VALVE CAPPED PIPE RISE IN PIPING DROP IN PIPING N 6 5 4 3 2 1 A B C D E 6 5 4 3 2 1 A B C D E Project No. Project Date Produced These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect. KEY PLAN B A 5/22/2023 6:05:33 PM C:\_RevitLocal\2023-067.POR_Bldg001_P_2023\2023-067.POR_Bldg001_P_2023_jbaughman.rvt 2023-067.POR 05.22.2023 PLUMBING SYMBOLS AND ABBREVIATIONS P-001 Designer JJB Coram Deo Academy Phase One Renovations 2023-067.POR_Coram Deo Academy_Phase One Renovations_ 525 Congressional Blvd, Carmel, IN 46032 P-001_ PLUMBING SYMBOLS AND ABBREVIATIONS # Revision Date ALL SUPPLY AIR BRANCH DUCTWORK TAKE- OFFS, AND/OR RECTUANGULAR TO ROUND WHERE REQUIRED. SUPPLY DIFFUSER CEILING SECURE FLEXIBLE DUCT TO SUPPLY DIFFUSER NECK WITH STAINLESS STEEL DRAWBAND TO INNER PART OF FLEX DUCT. PROVIDE FOIL TAPE TO SECURE INSULATION OVER DRAW BAND. SQUARE-TO-ROUND FITTING FOR SQUARE NECK SUPPLY DIFFUSERS INSULATED FLEXIBLE DUCTWORK MAXIMUM 5'-0" IN LENGTH AND NO MORE THAN ONE (1) 90° TURN FLEX BOOT LIKE MODEL "FLEXRIGHT" BY BUILDRIGHT PRODUCTS WHERE DIFFUSER IS LOCATED IN CEILING SPACE NOT USED AS A RETURN PLENUM, PROVIDE MANUFACTURER'S INSULATED BACK PAN ON DIFFUSER, AND FOIL TAPE EDGES. 1" BAND CLAMP WITH WIRE (OPTIONAL) MINIMUM 1" WIDE CLAMP WIRE SUPPORT STRAP BRACING SHALL BE PROVIDED AT A MAXIMUM OF 3'-0" ON CENTERS MAXIMUM SAG SHALL BE 1/2" PER FOOT OF SUPPORT SPACING DETAIL 1 DETAIL 2 DETAIL 3 NOTES: 1. METALLIC FLEXIBLE DUCTWORK SHALL BE ATTACHED USING A MINIMUM OF THREE (3) #8 SHEET METAL SCREWS EQUALLY SPACED AROUND THE DUCTWORK CIRCUMFERENCE. DUCTWORK LARGER THAN 12" SHALL HAVE A MINIMUM OF FIVE (5) #8 SHEET METAL SCREWS. SCREWS SHALL BE LOCATED AT LEAST 1/2" FROM THE DUCTWORK END. 2. NON-METALLIC FLEXIBLE DUCTWORK SHALL BE SECURED TO THE SLEEVE OR COLLAR USING A DRAW BAND. IF THE DUCTWORK COLLAR EXCEEDS 12" THE DRAW BAND MUST BE POSITIONED BEHIND A BEAD ON THE METAL COLLAR. 3. INSULATION AND VAPOR BARRIERS PRESENT ON FACTORY-FABRICATED DUCTWORK SHALL BE FITTED OVER THE CORE CONNECTION AND SHALL BE SUPPLEMENTALLY SECURED WITH A DRAW BAND. 4. FLEXIBLE DUCTWORK SEALING SHALL BE A CLASS "B" SEAL FOR LOW PRESSURE DUCTWORK. 5. SUPPORT SYSTEM SHALL NOT DAMAGE OR CAUSE OUT-OF-ROUND SHAPE. EXHAUST FAN SCHEDULE - 23 34 23 IDENTITY DATA WEIGHT (LBS) FAN DATA SOUND CRITERIA ELECTRICAL DATA MARK MANUFACTURER MODEL SERVICES FAN TYPE UNIT CONTROL NOTES DRIVE TYPE AIRFLOW (CFM) ESP (IN-WG) RPM HP BHP SONES DBA VOLTS (V) PH FREQ (HZ) EF-1 GREENHECK CUE-099-VG SCIENCE 40 UPBLAST CENTRIFUGAL DIRECT 990 0.75 1535.00 0.25 0.24 11.6 63 120 1 60 TIME CLOCK 1-4 EXHAUST FAN SCHEDULE NOTES: 1. DISCONNECT BY MANUFACTURER. 2. SEE M-700 SERIES SHEETS FOR TEMPERATURE CONTROL INFORMATION. 3. FAN SPEED CONTROLLER FOR BALANCING. 4. 24-HOUR TIMECLOCK TO ENERGIZE FAN ON SAME SCHEDULE AS ROOFTOP OCCUPANCY SCHEDULE. ELECTRIC CABINET UNIT HEATER SCHEDULE - 23 82 39 IDENTITY DATA WEIGHT (LBS) HEATING DATA FAN DATA ELECTRICAL DATA MARK MANUFACTURER MODEL NOTES CAPACITY (KW) STAGES AIRFLOW (CFM) ESP (IN-WG) FAN TYPE DRIVE VOLTS (V) PH FREQ (HZ) FLA (A) MOCP (A) ECUH-1 Q-MARK EFF4007 23 4.0 1 150 0.25 FC CENTRIFUGAL DIRECT 277 1 60 14.4 14.4 1 ECUH-2 Q-MARK EFF4007 23 4.0 1 150 0.25 FC CENTRIFUGAL DIRECT 277 1 60 14.4 14.4 1 ELECTRIC CABINET UNIT HEATER SCHEDULE NOTES: 1. DISCONNECT SWITCH BY MANUFACTURER. DISCONNECT SWITCH AND ALL INTERLOCK RELAYS TO BE INSTALLED WITHIN HEATER ENCLOSURE. EXHAUST FAN CONTROL: THE MOTORIZED BACKDRAFT DAMPER (MB-DPR) SHALL BE DRIVEN OPEN AND PROVEN VIA END-SWITCH CONTACTS TO PREVENT OPERATION OF THE EXHAUST FAN MOTOR WHEN CLOSED. DAMPER ACTUATOR WITH INTEGRAL END-SWITCH FURNISHED AND INSTALLED BY TCC. THE EXHAUST FAN SHALL BE STARTED ACCORDING TO THE OWNER-DEFINED SCHEDULE. IF THE EXHAUST FAN STATUS (EF-S) DOES NOT MATCH THE COMMANDED VALUE AFTER STROKE TIME PLUS 15 SECONDS (ADJ), AN ALARM SHALL BE GENERATED. SEE ELECTRICAL DRAWINGS FOR MOTOR STARTER LOCATION INFORMATION. BI EF-S BO HW MB-DPR NC ROOM AIR EXHAUST AIR ZN-T HEATER SEQUENCE OF OPERATION ZONE TEMPERATURE CONTROL : INTEGRAL THERMOSTAT (ZN-T) WILL ENERGIZE THE ELECTRIC HEATING TO MAINTAIN THE ZONE TEMPERATURE AT 70F (ADJ). MANUFACTURER PROVIDED AND WIRED SAFETIES SHALL ENSURE SAFE OPERATION. AREA SERVED HINGED ACCESS DOOR FOR FIRE DAMPER ACCESS FIRE RATED CHASE WALL, VERIFY EXACT FIRE RATING AND CONSTRUCTION ON ARCHITECTURAL DRAWINGS SOLID CEILING CONSTRUCTION ACCESS DOOR/PANEL SOLID CEILING CONSTRUCTION, VERIFY TYPE AND CONSTRUCTION ON ARCHITECTURAL DRAWINGS DUCTWORK TYPE "B" FIRE DAMPER FIRE DAMPER INSTALLATION SHALL BE IN STRICT ACCORDANCE WITH THE MANUFACTURER'S WRITTEN INSTRUCTIONS AND ALL UNDERWRITER'S LABORATORY (UL), FEDERAL, STATE AND LOCAL CODE REQUIREMENTS. FIRE DAMPER RATING SHALL MATCH FIRE RATING OF CHASE CONSTRUCTION. REFER TO ARCHITECTURAL DRAWINGS FOR RATING. DIVISION 23 CONTRACTOR SHALL FURNISH AND INSTALL A HINGED ACCESS DOOR IN THE DUCTWORK SIZED IN ACCORDANCE WITH THE SCHEDULE AND LOCATED TO PERMIT REPLACEMENT OF FUSIBLE LINK. LABEL FIRE DAMPER ACCESS DOOR WITH "FIRE DAMPER ACCESS." DIVISION 23 CONTRACTOR SHALL FURNISH ACCESS DOOR/PANEL FOR SOLID CEILING CONSTRUCTION IN ACCORDANCE WITH DIVISION 8 SPECIFICATION SECTION "ACCESS DOORS AND PANELS". ACCESS DOOR/PANEL LOCATED IN SOLID CEILING CONSTRUCTION SHALL BE NO SMALLER IN SIZE THAN THE ACCESS DOOR LOCATED IN THE DUCTWORK. NOTES: 1. 2. 3. 4. ACCESS DOOR / PANEL SCHEDULE DUCTWORK WIDTH ACCESS DOOR 6" 8" - 12" 13" - 18" 19" - 36" 37" - UP 6" x 6" 8" x 8" 12" x 12" 18" x 18" 24" x 24" N 6 5 4 3 2 1 A B C D E 6 5 4 3 2 1 A B C D E Project No. Project Date Produced These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect. KEY PLAN B A 5/22/2023 12:48:51 PM C:\_RevitLocal\2023-067.POR_Bldg001_M_2023\2023-067.POR_Bldg001_M_2023_tkennedy.rvt 2023-067.POR 05.22.2023 MECHANICAL DETAILS M-501 Designer Author Coram Deo Academy Phase One Renovations 2023-067.POR_Coram Deo Academy_Phase One Renovations_ 525 Congressional Blvd, Carmel, IN 46032 M-501_ MECHANICAL DETAILS 1A NOT RETURN TO SCALE GRILLE SOUND TRAP DETAIL 2A NOT TO SCALE POWER ROOF VENTILATOR INSTALLATION DETAIL 1B NOT OPEN TO SCALE PLENUM RETURN GRILLE DETAIL 1C NOT TO SCALE SUPPLY DIFFUSER FLEXIBLE DUCT CONNECTION DETAIL 2B NOT INSULATED TO SCALE FLEXIBLE DUCTWORK DETAIL 5B NOT TO SCALE ELECTRIC UNIT HEATER SEQUENCE OF OPERATIONS 5A NOT EXHAUST TO SCALE FAN SEQUENCE OF OPERATIONS 4C NOT FIRE TO SCALE DAMPER (WALL) DETAIL 233713 DIFFUSERS, REGISTERS, AND GRILLES IDENTITY DATA NECK SIZE (IN) MODULE SIZE MARK DESCRIPTION MANUFACTURER MODEL Ø W L MATERIAL NOTES TBDI 24-06 T-BAR SUPPLY DIFFUSER NAILOR 5810I 0" 0" 0" EC12/12 EGG CRATE FACE RETURN PRICE 80 12" 12" EC24/24 EGG CRATE FACE RETURN PRICE 80 24" 24" SD24-8 SQUARE CONE DIFFUSER PRICE ASCDA 8" 24" 24" SD24-10 SQUARE CONE DIFFUSER PRICE ASCDA 10" 24" 24" SD24-12 SQUARE CONE DIFFUSER PRICE ASCDA 12" 24" 24" # Revision Date 2023-067.POR 05.22.2023 MECHANICAL ROOF PLAN MR101 Designer Author Coram Deo Academy Phase One Renovations 2023-067.POR_Coram Deo Academy_Phase One Renovations_ 525 Congressional Blvd, Carmel, IN 46032 MR101_ MECHANICAL ROOF PLAN 1 MECHANICAL 3/32" = 1'-0" HVAC ROOF PLAN - AREA A 2 MECHANICAL 3/32" = 1'-0" HVAC ROOF PLAN - AREA B # Revision Date CLASSROOM B138 COMMONS B141 CLASSROOM B145 CLASSROOM B118 KITCHENETTE B122 OFFICE B119A CLASSROOM B110 CLASSROOM B126 STORAGE B146A STORAGE B146 CLASSROOM B130 CORRIDOR B001 OFFICE PRE-K B131 B132 CLASSROOM B119 CHAPEL B111 CAFETERIA B111A CLASSROOM B136 3 4 3 1 1 ECUH-1 4 ECUH-2 100 CFM 100 CFM 150 CFM 150 CFM 150 CFM 150 CFM 250 CFM 350 CFM 300 CFM 300 CFM 350 CFM EX. EC24/12 EX. EC24/12 SD24-8 250 SD24-8 250 250 CFM 250 CFM 24"x14" RA 400 CFM 400 CFM EX. EC24/12 EX. EC24/24 EX. EC24/24 EC24/24 EC24/24 10"Ø SA 10"Ø SA EX. EC24/12 18"x10" TA SD24-10 300 SD24-10 300 SD24-10 300 SD24-10 300 SD24-8 150 SD24-8 150 SD24-8 150 SD24-8 150 SD24-8 150 SD24-8 200 SD24-8 200 SD24-8 200 SD24-8 200 SD24-10 300 SD24-10 300 SD24-10 150 SD24-10 250 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3 SD24-12 TBDI 24-06 TBDI 24-06 TBDI 24-06 TBDI 24-06 TBDI 24-06 EC24/24 1 1 1 1 1 1 EC24/24 SD24-8 CAP EXISTING DUCTWORK 250 1 200 CFM B137 CLASSROOM B137A OFFICE A. B. DARK LINES INDICATE NEW WORK. LIGHT SOLID LINES INDICATE EXISTING MECHANICAL EQUIPMENT, DUCTWORK, PIPING, AND/OR MECHANICAL ACCESSORIES TO REMAIN AS-IS. CONTRACTOR TO FIELD VERIFY ACTUAL EXISTING CONDITIONS PRIOR TO BIDDING. GENERAL HVAC NOTES N 6 5 4 3 2 1 A B C D E 6 5 4 3 2 1 A B C D E Project No. Project Date Produced These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect. KEY PLAN B A 5/22/2023 12:48:38 PM C:\_RevitLocal\2023-067.POR_Bldg001_M_2023\2023-067.POR_Bldg001_M_2023_tkennedy.rvt 2023-067.POR 05.22.2023 FIRST FLOOR HVAC PLAN - UNIT B MH1B1 Designer Author Coram Deo Academy Phase One Renovations 2023-067.POR_Coram Deo Academy_Phase One Renovations_ 525 Congressional Blvd, Carmel, IN 46032 MH1B1_ FIRST FLOOR HVAC PLAN - UNIT B 1A Level 1/8" = 1'-0" 1 - HVAC PLAN - UNIT B MECHANICAL HVAC PLAN NOTES # NOTE 1 REINSTALL AIR TERMINAL IN NEW CEILING. EXTEND EXISTING SHEETMETAL DUCTWORK TO INLET OF AIR TERMINAL. 2 ALTERNATE: ROUTE 12" ROUND EXHAUST AIR DUCT THROUGH ROOF TO EF-A1. EXHAUST FAN TO BE CONTROLLED BY TIME CLOCK PER DETAIL ON M-501. TIME CLOCK TO MATCH EXISTING ROOFTOP NIGHT-SETBACK SCHEDULE. 3 PROVIDE NEW THERMOSTAT ON WALL. MOUNT THEMOSTAT WTIH TOP AT 48" ABOVE FINISHED FLOOR. PROVIDE LOCKABLE PLASTIC CAGE LIKE BAPI GUARD. 4 INSTALL NEW ECUH IN CEILING PER MANUFACTURER'S RECOMMENDATIONS. # Revision Date UNOCCUPIED A123 BREAK ROOM A106 STORAGE A106A OFFICE A104 CORRIDOR A001 PRACTICE ROOM B117A STORAGE B101 STORAGE B102 CLINIC A101 LOBBY A100 VESTIBULE A003A STORAGE A117 UNOCCUPIED A126 UNOCCUPIED A125 UNOCCUPIED A127 OFFICE A119 CLASSROOM A118 UNOCCUPIED A130 UNOCCUPIED A129 UNOCCUPIED A128 VESTIBULE A003B STORAGE A112 CORRIDOR A003 VESTIBULE A100A MENS RR B103 CORRIDOR A002 STORAGE A110A CLASSROOM B117 VESTIBULE A110B RR A110C GYM A110 1 2 3 10"Ø EA EC12/12 300 SD24-12 350 SD24-12 350 SD24-8 225 SD24-8 225 SD24-12 350 SD24-12 350 EC24/24 SD 18"x12" TA CAP EXISTING DUCTWORK 12"Ø EA EC24/24 SD SD 12"x8" SA 18"x12" SA 1 1 1 1 1 1 SD24-8 A. B. DARK LINES INDICATE NEW WORK. LIGHT SOLID LINES INDICATE EXISTING MECHANICAL EQUIPMENT, DUCTWORK, PIPING, AND/OR MECHANICAL ACCESSORIES TO REMAIN AS-IS. CONTRACTOR TO FIELD VERIFY ACTUAL EXISTING CONDITIONS PRIOR TO BIDDING. GENERAL HVAC NOTES N 6 5 4 3 2 1 A B C D E 6 5 4 3 2 1 A B C D E Project No. Project Date Produced These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect. KEY PLAN B A 5/22/2023 12:48:35 PM C:\_RevitLocal\2023-067.POR_Bldg001_M_2023\2023-067.POR_Bldg001_M_2023_tkennedy.rvt 2023-067.POR 05.22.2023 FIRST FLOOR HVAC PLAN - UNIT A MH1A1 Designer Author Coram Deo Academy Phase One Renovations 2023-067.POR_Coram Deo Academy_Phase One Renovations_ 525 Congressional Blvd, Carmel, IN 46032 MH1A1_ FIRST FLOOR HVAC PLAN - UNIT A 1A Level 1/8" = 1'-0" 1 - HVAC PLAN - UNIT A MECHANICAL HVAC PLAN NOTES # NOTE 1 REINSTALL AIR TERMINAL IN NEW CEILING. EXTEND EXISTING SHEETMETAL DUCTWORK TO INLET OF AIR TERMINAL. 2 ALTERNATE: ROUTE 12" ROUND EXHAUST AIR DUCT THROUGH ROOF TO EF-A1. EXHAUST FAN TO BE CONTROLLED BY TIME CLOCK PER DETAIL ON M-501. TIME CLOCK TO MATCH EXISTING ROOFTOP NIGHT-SETBACK SCHEDULE. 3 PROVIDE NEW THERMOSTAT ON WALL. MOUNT THEMOSTAT WTIH TOP AT 48" ABOVE FINISHED FLOOR. PROVIDE LOCKABLE PLASTIC CAGE LIKE BAPI GUARD. 4 INSTALL NEW ECUH IN CEILING PER MANUFACTURER'S RECOMMENDATIONS. # Revision Date 6 5 4 3 2 1 A B C D E 6 5 4 3 2 1 A B C D E Project No. Project Date Produced These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect. KEY PLAN B A 5/22/2023 12:48:32 PM C:\_RevitLocal\2023-067.POR_Bldg001_M_2023\2023-067.POR_Bldg001_M_2023_tkennedy.rvt 2023-067.POR 05.22.2023 FIRST FLOOR DEMOLITION PLAN - UNIT B MD1B1 Designer Author Coram Deo Academy Phase One Renovations 2023-067.POR_Coram Deo Academy_Phase One Renovations_ 525 Congressional Blvd, Carmel, IN 46032 MD1B1_ FIRST FLOOR DEMOLITION PLAN - UNIT B 1A Level 1/8" = 1'-0" 1 - MECHANICAL DEMOLITION PLAN - UNIT B DEMOLITION HVAC PLAN # NOTE 1 BASE AND ALTERNATE BID: REMOVE AIR TERMINAL AND ASSOCIATED FLEXIBLE DUCTWORK, INSPECT, PAINT, AND REPAIR AIR TERMINAL AS NECESSARY. RETAIN AIR TERMINAL FOR REINSTALLATION. 1 BASE BID: INSPECTAND REPAIR DIFFUSERS AS NECESSARY. PROTECT DIFFUSERS THOUGHOUT CONSTRUCTION. 2 REMOVE AIR TERMINAL AND ASSOCIATED FLEXIBLE DUCTWORK TO CONNECTION AT SHEETMETAL DUCT. RETAIN AIR TERMINAL FOR REINSTALLATION. PAINT AND REPAIR AS NECESSARY, REPLACE AS REQUIRED. 3 REMOVE THERMOSTAT FROM WALL. COORDINATE WITH ARCHITECTURE AND INTERIORS PLANS TO DETERMINE IF PATCH AND REPAIR IS NECESSARY. 4 MECHANICAL CONTRACTOR TO CONDUCT AIRFLOW TEST FOR EXISTING AIRFLOW RATE PRIOR TO DEMOLITION. 5 REMOVE AIR TERMINAL COMPLETE, REMOVE AND CAP EXISTING DUCTWORK AT NORTH WALL. 6 PROTECT THERMOSTAT DURING CONSTRUCTION. # Revision Date B C D E 6 5 4 3 2 1 A B C D E Project No. Project Date Produced These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect. KEY PLAN B A 5/22/2023 12:48:30 PM C:\_RevitLocal\2023-067.POR_Bldg001_M_2023\2023-067.POR_Bldg001_M_2023_tkennedy.rvt 2023-067.POR 05.22.2023 FIRST FLOOR DEMOLITION PLAN - UNIT A MD1A1 Designer Author Coram Deo Academy Phase One Renovations 2023-067.POR_Coram Deo Academy_Phase One Renovations_ 525 Congressional Blvd, Carmel, IN 46032 MD1A1_ FIRST FLOOR DEMOLITION PLAN - UNIT A 1A Level 1/8" = 1'-0" 1 - MECHANICAL DEMOLITION PLAN - UNIT A DEMOLITION HVAC PLAN # NOTE 1 BASE AND ALTERNATE BID: REMOVE AIR TERMINAL AND ASSOCIATED FLEXIBLE DUCTWORK, INSPECT, PAINT, AND REPAIR AIR TERMINAL AS NECESSARY. RETAIN AIR TERMINAL FOR REINSTALLATION. 1 BASE BID: INSPECTAND REPAIR DIFFUSERS AS NECESSARY. PROTECT DIFFUSERS THOUGHOUT CONSTRUCTION. 2 REMOVE AIR TERMINAL AND ASSOCIATED FLEXIBLE DUCTWORK TO CONNECTION AT SHEETMETAL DUCT. RETAIN AIR TERMINAL FOR REINSTALLATION. PAINT AND REPAIR AS NECESSARY, REPLACE AS REQUIRED. 3 REMOVE THERMOSTAT FROM WALL. COORDINATE WITH ARCHITECTURE AND INTERIORS PLANS TO DETERMINE IF PATCH AND REPAIR IS NECESSARY. 4 MECHANICAL CONTRACTOR TO CONDUCT AIRFLOW TEST FOR EXISTING AIRFLOW RATE PRIOR TO DEMOLITION. 5 REMOVE AIR TERMINAL COMPLETE, REMOVE AND CAP EXISTING DUCTWORK AT NORTH WALL. 6 PROTECT THERMOSTAT DURING CONSTRUCTION. # Revision Date SF SAT PTS F&T FLOAT & THERMOSTATIC STEAM TRAP FIRE DAMPER FTR GAL GA FT FPM FTG FINNED TUBE RADIATION GALLON GAUGE FEET PER MINUTE FOOTING FOOT/FEET FLR FCP FD FCU FLOOR FLUID COOLER PUMP FAN COIL UNIT RV RS RP RPM RM RHG RL RG RHC RH RAT RECIR RES RF R RA R(#) ENTERING WATER TEMPERATURE (°F) EVAPORAT(E), (ING), (ED), (OR) EXTERNAL STATIC PRESSURE (IN WG) EX EXP F&B °F EUH EVAP ET EWT DEGREES FAHRENHEIT FACE AND BY-PASS EXPANSION EXISTING EXPANSION TANK ELECTRIC UNIT HEATER EMER ENCL EOM ESP EQUIP EF EFF ELEV ELEC EG EMERGENCY END OF MAIN DRIP EQUIPMENT ENCLOSURE EXHAUST GRILLE ELEVATION ELECTRIC EFFICIENCY EXHAUST FAN PSIG PT PRESS PSI PREFAB PPM PNEU PER (%) PHWR PHWS PI PHC PH PCHS PD PE PCHR SUPPLY AIR STORAGE TANK PUMP STORAGE TANK SUPPLY STRUCTURE(E), (AL) STORAGE TANK STAINLESS STEEL STANDARD SAFETY RELIEF VALVE SPECIFICATIONS SHEET STEAM CONDENSATE COOLER SUPPLY AIR TEMPERATURE (°F) SUPPLY DIFFUSER SENSIBLE HEAT RATIO SUPPLY GRILLE SQUARE FOOT SECTION SUPPLY FAN PNEUMATIC TUBE STATION RELATIVE HUMIDITY RADIANT PANEL (CEILING-MOUNTED) REVOLUTIONS PER MINUTE REFRIGERANT SUCTION REFRIGERANT VENT RELATIVE HUMIDITY REFRIGERANT HOT GAS REFRIGERANT LIQUID REHEAT COIL RETURN GRILLE ROOM RECIRCULAT(E), (OR), (ING) RETURN AIR TEMPERATURE (°F) RETURN FAN THERMAL RESISTANCE REFRIGERANT (NUMBER) RETURN AIR POUNDS PER SQUARE INCH POUNDS PER SQUARE INCH GAUGE PNEUMATIC TUBE PRESSURE PARTS PER MILLION PREFABRICATED PNEUMATIC PANEL CHILLED WATER SUPPLY PERIMETER HEATING HOT WATER RETURN PERIMETER HEATING HOT WATER SUPPLY PRESSURE DROP (IN OR WG AS NOTED) PANEL CHILLED WATER RETURN PERCENT PRESSURE INDICATOR PREHEAT COIL PHASE PNEUMATIC-ELECTRIC BFW BOILER FEED WATER MISC CONV CONVECTOR ENTERING AIR TEMPERATURE (°F) CONDENSER WATER CHEMICAL FEED CLASSROOM UNIT VENTILATOR EA EAT EC DN DWG ELECTRICAL CONTRACTOR EXHAUST AIR DRAWING DOWN CWP CWCF D DB CP CT CV CUV CUH CONDENSER WATER PUMP DRAIN BOX DRAIN CONTROL VALVE COOLING TOWER CABINET UNIT HEATER CONDENSATE PUMP P PBD OFOI OFCI OBD OA OAT NA NO NTS NIC NC MV MTD CONTRACTOR FURNISHED/OWNER INSTALLED CHILLED WATER RETURN CHILLED WATER CHEMICAL FEED BRITISH THERMAL UNIT PER HOUR CO CI CONN CHWR CF CFM CFOI CH CHCF CHP CONNECTION CAST IRON CLEANOUT CHILLED WATER PUMP CUBIC FEET PER MINUTE CHILLER CUBIC FEET CD BTUH CAB CAV BHP BFWP BOD BOP BLDG CONSTANT AIR VOLUME CONDENSATE DRAIN CABINET BOTTOM OF PIPING BOTTOM OF DUCT BRAKE HORSEPOWER BOILER FEED WATER PUMP BUILDING MIN MECH MD MCC MC MBH MAT LWT LPS LFC LFD LP LEC LD ACCESS DOOR ("M" DWGS). AREA DRAIN ("P" DWGS) AIR COOLED CONDENSING UNIT AMPERE (AMP, AMPS) BBD BFC BDD AMP ARCH AS AV APD APPROX BOILER BLOW DOWN BACKDRAFT DAMPER BELOW FINISHED CEILING AIR PRESSURE DROP (IN WG) ARCHITECT (URAL) APPROXIMAT(E), (LY) AIR SEPARATOR AUTOMATIC VENT ADJ AFF AHU ALTER AFM ACCU ACU AD ADA AAF ADJUSTABLE AIR FLOW MONITORING ABOVE FINISHED FLOOR AIR HANDLING UNIT ALTERNATE AIR CONDITIONING UNIT AUTOMATIC AIR VENT AMERICAN DISABILITIES ACT LBS LAT LAF LAD LAB KW KEC IN INDIC INSUL INT INCIN INCL IB ID HHWS HZ UV UNIT VENTILATOR VARIABLE FREQUENCY DRIVE W/O WITHOUT MISCELLANEOUS OWNER FURNISHED/CONTRACTOR INSTALLED OWNER FURNISHED/OWNER INSTALLED OUTSIDE AIR TEMPERATURE (°F) PARALLEL BLADE DAMPER PUMP OPPOSED BLADE DAMPER OUTSIDE AIR NOT APPLICABLE NORMALLY CLOSED NORMALLY OPEN NOT TO SCALE NOT IN CONTRACT MANUAL VENT MOUNTED ZN WTR WPD ZONE WATER PRESSURE DROP WATER MIXED AIR TEMPERATURE (°F) THOUSANDS OF BTU PER HOUR MOTOR CONTROL CENTER MOTORIZED DAMPER MECHANICAL MINIMUM MECHANICAL CONTRACTOR MAXIMUM LABORATORY FURNISHINGS CONTRACTOR LOW PRESSURE STEAM LEAVING WATER TEMPERATURE (°F) LABORATORY EQUIPMENT CONTRACTOR LAMINAR FLOW DIFFUSER LIQUID PETROLEUM LINEAR DIFFUSER WG W/ WATER GAUGE WITH VB VERT VFD VIF VC VD VAC VAR VAV VA VACUUM BREAKER VOLUME DAMPER VERIFY IN FIELD VACUUM CLEANING VERTICAL VOLT AMPERE VARIABLE AIR VOLUME VACUUM VARIABLE TEMPERATURE CONTROL CONTRACTOR TEMPERATURE DIFFERENCE TOTAL STATIC PRESSURE (IN WG) UNLESS NOTED OTHERWISE HEAT TRANSFER COEFFICIENT LEAVING AIR TEMPERATURE (°F) KITCHEN EQUIPMENT CONTRACTOR LAMINAR AIR FLOW LAMINAR AIR DIFFUSER LABORATORY POUND KILOWATT HEATING HOT WATER SUPPLY INVERTED BUCKET STEAM TRAP INCH/INCHES INSULAT(E), (ED), (ION) INCLUD(E), (ED) INCINERATOR INDICATOR INTERIOR FREQUENCY (MEGAHERTZ) INSIDE DIAMETER UNO UC UH U TYP. TSTAT TSP UNIT HEATER UNDER CUT THERMOSTAT TYPICAL TC TEMP TONS TCC TD SV TB SUCT TEMPERATURE CONTROL TONS OF REFRIGERATION TEMPERATURE STEAM VENT TERMINAL BOX SUCTION CWR CONDENSER WATER RETURN CWS CONDENSER WATER SUPPLY COP COEFFICIENT OF PERFORMANCE CHWS CHILLED WATER SUPPLY EER ENERGY EFFICIENCY RATIO SEER SEASONAL ENERGY EFFICIENCY RATIO HTR HEATER MAX STR STORAGE TANK RETURN VRV VARIABLE REFRIGERANT VOLUME BSB BRANCH SELECTOR BOX ABBREVIATIONS C COMMON LPC LOW PRESSURE CONDENSATE MPC MEDIUM PRESSURE CONDENSATE MPS MEDIUM PRESSURE STEAM HPS HIGH PRESSURE STEAM HPC HIGH PRESSURE CONDENSATE GFS GLYCOL FILL STATION 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. 32. 33. 34. 35. 36. 37. 38. 39. 40. 41. 42. 43. 44. 45. 46. 47. THESE GENERAL NOTES APPLY TO M-SERIES DRAWINGS. ADDITIONAL GENERAL NOTES SPECIFIC TO A PARTICULAR DRAWING ARE NOTED ON THOSE SHEETS. IT IS THE INTENT OF THESE DOCUMENTS TO PROVIDE MECHANICAL SYSTEMS THAT ARE FULLY FUNCTIONAL. PROVIDE ALL ITEMS SPECIFIED AND REQUIRED FOR COMPLETE OPERATIONAL SYSTEMS. ON MECHANICAL "M" SERIES DRAWINGS, DARK LINE ITEMS INDICATE NEW WORK. LIGHT LINE ITEMS ARE ITEMS THAT SHALL REMAIN. THESE DRAWINGS INDICATE REQUIRED SIZE AND POINTS OF TERMINATION FOR PIPING, DUCTWORK, CONDUIT, ETC. THE EQUIPMENT SHOWN ILLUSTRATES SUGGESTED ROUTING, BUT ALL NECESSARY OFFSETS MAY NOT BE SHOWN. DIVISION 23 SHALL INSTALL HIS WORK IN A MANNER THAT WILL CONFORM WITH THE STRUCTURE. DIVISION 23 SHALL AVOID OBSTRUCTIONS, PRESERVE HEADROOM AND MAINTAIN MAXIMUM CLEARANCE WITHOUT FURTHER INSTRUCTION FROM THE ARCHITECT/ENGINEER OR ADDITIONAL COST TO THE OWNER. ALL DUCTWORK, PIPING, AND VALVES SHALL BE CONCEALED ABOVE CEILING AND WITHIN WALLS IN FINISHED AREAS UNLESS OTHERWISE INDICATED. ALL VALVES, ETC. SHALL BE INSTALLED ALLOWING EASY ACCESS BETWEEN LIGHT FIXTURES AND NO HIGHER THAN 12" TO 24" ABOVE THE CEILING. PROVIDE FITTINGS IN DUCTWORK AND PIPING AS REQUIRED SO THAT NO PIPING REMAINS TIGHT TO ROOF STRUCTURE. PROVIDE ACCESS PANELS AS REQUIRED. AREA ADJACENT TO THE ACCESS PANELS SHALL BE CLEAR OF ANY OBSTRUCTIONS. PROVIDE EXTENDED VALVE HANDLES FOR INSULATED PIPING. DIVISION 23 SHALL BE GUIDED BY THE ARCHITECT/ENGINEER'S REFLECTED CEILING PLAN FOR LOCATION OF DIFFUSERS, REGISTERS, GRILLES SHOWN OR COVERED BY THESE PLANS. RETURN GRILLES SHALL NOT ALIGN WITH SUPPLY AIR THROW. CONTRACTOR SHALL COORDINATE EXACT LOCATION OF ALL GRILLES, REGISTERS AND DIFFUSERS IN CEILINGS WITH THE CEILING SYSTEM AND LIGHT FIXTURES. PROVIDE FLEXIBLE DUCT UPSTREAM OF EACH DIFFUSER WHERE SHOWN. ARROWS ON THE HOT WATER COLD WATER MAINS INDICATE THE DIRECTION OF FLOW. PITCH MAINS UPWARD A MINIMUM OF 1" PER 60' IN THE DIRECTION OF FLOW. ARROWS ON STEAM AND CONDENSATE PIPING AND DRAIN LINE INDICATE THE DOWNWARD PITCH OF THE PIPING. INSTALL AIR VENTS AT ALL HIGH POINTS AND DRAINS AT ALL LOW POINTS OF WATER PIPING SYSTEMS. DRAINS TO HAVE HOSE END THREADS WITH CLEARANCE TO ATTACH HOSE. PIPING BRANCHES TO EQUIPMENT SHALL HAVE SAME SIZE VALVES AND FITTINGS AS THAT OF THE LINE SIZE WITH THE EXCEPTION OF THE TEMPERATURE CONTROL VALVES. PIPE "SWING" CONNECTIONS WITH UNIONS OR FLANGES SHALL BE MADE EXTERNAL TO COILS OR A TUBE BUNDLE TO FACILITATE REMOVAL OF THAT ITEM WITHOUT DISTURBING THE BRANCH VALVES AND/OR PIPING. DUCT AND PIPING PENETRATING FLOOR SLABS AND/OR WALLS SHALL BE SEALED WITH ACOUSTIC SEALANT. IF THE FLOOR OR WALL IS FIRE RATED PROVIDE THE FIRE STOPPING OR FIRE DAMPER TO MAINTAIN THE FIRE RATING. ALL RECTANGULAR SHEET METAL DUCT SIZES ARE INSIDE DIMENSIONS. ALL ROUND DUCT SIZES SHOWN ARE INSIDE DIAMETERS. ALLOWANCE FOR ACOUSTICAL LINER WHERE INDICATED ON DRAWINGS MUST BE ADDED TO OBTAIN OUTSIDE SHEET METAL DIMENSION. ALL WALL THERMOSTATS, TEMPERATURE SENSORS, AND/OR HUMIDISTATS SHALL BE APPROXIMATELY 46" ABOVE FINISHED FLOOR TO CENTER AND LINED UP HORIZONTALLY WITH LIGHT SWITCHES UNLESS OTHERWISE NOTED OR DIRECTED BY THE ARCHITECT/ENGINEER. DIVISION 23 CONTRACTOR SHALL BE RESPONSIBLE FOR HIS RESPECTIVE WORK FOR REPAIRING AND PATCHING TO MATCH EXISTING SURFACES, SIDEWALKS, STREETS, FLOORS, WALLS, ROOFS, CEILING AND PAVEMENT. CONTRACTOR SHALL INCLUDE IN BID PROPOSAL ALL COSTS FOR CUTTING AND PATCHING REQUIRED TO INSTALL NEW OR REMOVE EXISTING WORK, EQUIPMENT, OR SYSTEMS. DIVISION 23 CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ALL OF HIS WORK TO BE INSTALLED WITH ANY AND ALL OTHER CONTRACTORS TO BE AFFECTED BY SUCH WORK, PRIOR TO ORDERING ANY OF THE EQUIPMENT. THIS SHALL INCLUDE BUT NOT LIMITED TO ELECTRICAL CHARACTERISTICS, CONNECTIONS REQUIRED, PHYSICAL SIZE, COLOR AND FIT. ALSO REFER TO SPECIFICATIONS. ALL EQUIPMENT SHALL BE OF, AND CONSIST OF, AT LEAST MINIMUM SIZES SELECTED, AND SHALL PERFORM TO OR SURPASS THE MINIMUM REQUIREMENTS, SCHEDULES, NOTED AND SPECIFIED. COORDINATE INSTALLATION OF NEW WORK WITH ALL OTHER TRADES AND EXISTING CONDITIONS AS REQUIRED FOR A COMPLETE AND OPERABLE HVAC SYSTEM. CLEARANCES ABOVE CEILINGS ARE EXTREMELY TIGHT IN CERTAIN AREAS. RELOCATE PIPING, ELECTRIC CONDUIT, STRUCTURAL BRACING, ETC., AS REQUIRED FOR A COMPLETE INSTALLATION OF HVAC WORK. COORDINATE ROUTING OF NEW DUCTWORK ABOVE CEILINGS WITH EXISTING ELECTRIC CABLE TRAY. M.C. TO COORDINATE ALL DUCTWORK ROUTING AND DUCTWORK ELEVATIONS WITH STRUCTURAL STEEL SUPPORTS FOR FOLDING WALLS. REFERENCE STRUCTURAL DRAWINGS FOR SIZE AND LOCATIONS OF STEEL. FIELD VERIFY ALL EXISTING CONDITIONS. CONTRACTOR SHALL COORDINATE EXACT LOCATION OF ALL VAV REHEAT BOXES AND DUCTWORK WITH THE CEILING SYSTEM AND LIGHT FIXTURES. FIELD VERIFY EXISTING CEILING SYSTEMS AND LOCATION OF EXISTING LIGHT FIXTURES. ALLOW REQUIRED CLEARANCES FOR SERVICE TO BOX AND CONTROLS. CONTRACTOR SHALL RELOCATE EXISTING LIGHT FIXTURE AND CEILING GRID SUPPORT HANGERS AS REQUIRED FOR INSTALLATION OF NEW VAV REHEAT BOXES, DUCTWORK AND PIPING. PROVIDE VOLUME DAMPERS IN ALL SUPPLY AIR BRANCH DUCTWORK AS REQUIRED TO BALANCE EACH SYSTEM. ALL VOLUME DAMPERS LOCATED ABOVE DRYWALL CEILINGS SHALL BE CABLE OPERATED WITH REMOTE REGULATOR LIKE YOUNG REGULATOR. FIELD VERIFY EXISTING CEILINGS FOR DRYWALL CEILINGS. COORDINATE LOCATION OF ALL DAMPERS WITH AIR BALANCE CONTRACTOR. IN HARD CEILINGS PROVIDE VOLUME DAMPER BEHIND THE GRILLE, REGISTER, OR DIFFUSER. PROVIDE 45°/90° FITTING WITH VOLUME DAMPER LIKE FLEXMASTER MODEL STO AT ALL SUPPLY AIR AND PRIMARY AIR BRANCH DUCTWORK TAKEOFFS. CONTRACTOR SHALL REVIEW RETURN AIR PATH BACK TO ALL HVAC EQUIPMENT. PROVIDE RETURN AIR OPENINGS AND/OR JUMPER DUCTS IN WALLS ABOVE THE CEILING WHERE REQUIRED. COORDINATE WITH GENERAL TRADES. VELOCITY THRU R.A. OPENINGS SHALL NOT EXCEED 500 FPM. FIELD VERIFY LOCATION OF EXISTING WALLS EXTENDING TO DECK. ALL TRANSFER AIR DUCTS TO BE INTERNALLY INSULATED TO DETER NOISE TRANSFER. SIZE SHOWN ON PLANS INDICATES ACTUAL FREE AREA. ALL NEW PIPING AND DUCTWORK CROSSING THRU EXISTING CORRIDOR AND/OR CLASSROOM WALLS TO DECK; CUT WALLS AS REQUIRED. COORDINATE ALL OPENINGS THROUGH EXISTING WALL CONSTRUCTION WITH GENERAL TRADES. SEAL AROUND DUCTWORK AND PIPING TO HELP REDUCE THE TRANSFER OF NOISE BETWEEN CLASSROOMS. FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING OF BID. ROUND DUCT SIZE TO BE THE SAME SIZE AS THE DIFFUSER NECK; UNLESS OTHERWISE NOTED. MAXIMUM LENGTH OF FLEXIBLE DUCTWORK CONNECTED TO A DIFFUSER SHALL BE 5'-0". ALL DUCTWORK CONSTRUCTION SHALL BE FABRICATED SHEET METAL & BUILT IN ACCORDANCE WITH "SMACNA" STANDARDS. ALL SUPPLY, RETURN, RELIEF/EXHAUST, AND OUTDOOR AIR DUCTWORK SHALL BE EXTERNALLY INSULATED. SEE SPECIFICATION FOR ADDITIONAL INSULATION REQUIREMENTS. ALL ROUND DUCT TO BE EXTERNALLY INSULATED UNLESS NOTED OTHERWISE. SIZE SHOWN INDICATES ACTUAL DUCT FREE AREA. SEE SPECIFICATION FOR ADDITIONAL INSULATION REQUIREMENTS. ALL NEW ROOF WORK TO BE IN ACCORDANCE WITH OWNER'S EXISTING ROOF WARRANTY. ALL ROOF PENETRATIONS TO BE SEALED WATER TIGHT. PACK VOID BETWEEN DUCT PENETRATING ROOF AND STRUCTURE WITH FIBERGLASS INSULATION AND CAULK WATER TIGHT. FOR HIGH TEMPERATURE OR GREASE DUCTS UTILIZE MINERAL WOOL. TEMPERATURE CONTROL CONTRACTOR SHALL PROVIDE ALL CONTROL WIRING COMPLETE FOR THIS PROJECT. ALL WIRING (AND INTERLOCK WIRING) TO THERMOSTATS, SPACE SENSORS, HUMIDISTATS, CARBON DIOXIDE MONITORS, ETC. ARE TO BE CONCEALED WITHIN THE WALL. ALL HARD 90° ELBOWS IN SUPPLY DUCTWORK ARE TO HAVE TURNING VANES PER SPECIFICATION AIR DUCT ACCESSORIES. REMOVE ALL WORK MADE OBSOLETE BY NEW CONSTRUCTION. DEMOLITION OF EXISTING MECHANICAL EQUIPMENT TO INCLUDE ASSOCIATED PIPING AND DUCTWORK NECESSARY FOR NEW EQUIPMENT INSTALLATION. ALL EXISTING TO REMAIN AND NEW PVC PLUMBING VENT LINES LOCATED ABOVE CEILING IN RETURN PLENUM ARE TO BE EXTERNALLY WRAPPED WITH FLAME AND SMOKE SPREAD RATED INSULATION MATERIAL AS REQUIRED. REFERENCE SECTION DIVISION 01 "SUMMARY" [MULTIPLE CONTRACT SUMMARY] FOR CONSTRUCTION PHASING. CONTRACTOR SHALL THOROUGHLY EXAMINE THE CONTRACT DOCUMENTS, INCLUDING THE WORK OF OTHER CONTRACTORS PRIOR TO SUBMITTING A BID PROPOSAL. ALL EXHAUST FANS, RELIEF VENTS, FLUES, AND PLUMBING VENTS TO BE INSTALLED A MINIMUM OF 10 FT. FROM OUTDOOR AIR INTAKES. CONTRACTOR SHALL CLEAN ALL OF HIS WORK INSIDE AND OUT. AIR DISTRIBUTION SYSTEMS SHALL HAVE ALL DIRT AND FOREIGN MATERIAL REMOVED FROM INSIDE AND OUTSIDE OF DUCTS, PLENUMS, HOUSINGS, DEVICES, TERMINALS, ETC. AS INSTALLATION PROGRESSES, PROTECT OPEN ENDS OF DUCTWORK AND INLETS AND OUTLETS OF EQUIPMENT AND DEVICES DURING CONSTRUCTION. CLEAN ALL ACCESSIBLE PARTS OF DUCTWORK AND AIR PASSAGES IN EQUIPMENT BEFORE FILTERS ARE INSTALLED OR REPLACED FOR SYSTEM BALANCING. FURNISH AND INSTALL ACCEPTABLE CONCRETE INSERTS, ANCHORS, CLAMPS, BRACKETS, HANGERS, STRUCTURAL MEMBERS (ANGLES, CHANNELS, ETC.) AND FRAMES, ETC., REQUIRED FOR SUPPORTING ALL RESPECTIVE WORK. SUPPORTING DEVICES, ASSEMBLIES AND ATTATCHMENTS SHALL BE DESIGNED AND ARRANGED TO CARRY THE WEIGHT OF THE SUPPORTED ITEMS INCLUDING HANGER AND CONTENTS WITHOUT TRANSMITTING VIBRATION OR NOISE TO THE BUILDING CONSTRUCTION; DESIGNED, APPROPRIATE AND APPROVED FOR THE PURPOSE USED; HAVE A NEAT AND FINISHED APPEARANCE AND COMPLEMENT THE INSTALLATION; HAVE CORROSION PROTECTION SUITABLE FOR THE ATMOSPHERE WHERE INSTALLED; ADEQUATELY AND SAFELY ATTACHED TO THE BUILDING STRUCTURE OR STRUCTURAL MEMBERS. EXPOSED SUPPORTS SHALL BE PAINTED UNLESS OF NON-FERROUS MATERIAL OR PROVIDED WITH PLATED (RUSTPROOF) FINISH. PROVIDE NEC CLEARANCES AND SERVICE CLEARANCES FOR EQUIPMENT. COORDINATE EQUIPMENT SERVICE ACCESS. CLEARANCES INDICATED ARE BASED UPON BEST AVAILABLE INFORMATION. CONTRACTOR SHALL VERIFY PIPING, DUCTWORK, ETC., ROUTING PRIOR TO SUBMITTING A BID PROPOSAL AND INCLUDE ANY SUCH COSTS AS REQUIRED TO INSTALL WORK AS SHOWN AND INTENDED. EXISTING VALVES MADE INACCESSIBLE BY NEW DUCT AND/OR PIPING SHALL BE RELOCATED AS REQUIRED FOR ACCESS. DURING REMOVAL OF ITEMS, CAUTION SHALL BE USED TO PREVENT DAMAGE TO ANY EQUIPMENT HAVING SALVAGE VALUE. ALL REUSABLE SALVAGED MATERIAL SHALL REMAIN THE PROPERTY OF THE OWNER AND BE RETAINED FOR HIS INSPECTION. ONLY ITEMS SO INSPECTED AND REJECTED BY THE OWNER SHALL BE DISPOSED OF BY THE CONTRACTOR. ALL OTHER ITEMS SHALL BE TURNED OVER AND DEPOSITED AS DIRECTED BY THE OWNER. CONTRACT DOCUMENTS CONSIST OF BOTH PROJECT MANUAL AND DRAWINGS AND BOTH ARE MEANT TO BE COMPLEMENTARY - ANYTHING APPEARING ON EITHER MUST BE EXECUTED THE SAME AS IF SHOWN ON BOTH. VERIFY EXACT SIZE AND LOCATION OF ALL EXISTING PIPING AND DUCTWORK PRIOR TO CONSTRUCTION OR BIDDING. GENERAL NOTES CO2 EQUIPMENT SYMBOLS SUPPLY DIFFUSER W/TYPE AND CFM (ONE-WAY SIDE TYPE) LINEAR DIFFUSER W/TYPE AND CFM (TWO-WAY SIDE TYPE) SUPPLY DIFFUSER W/TYPE AND CFM (THREE-WAY TYPE) SIDEWALL GRILLE W/TYPE AND CFM RETURN GRILLE W/ TYPE AND CFM SUPPLY DIFFUSER W/TYPE AND CFM (FOUR-WAY TYPE) SUPPLY DIFFUSER W/TYPE AND CFM (TWO-WAY SIDE TYPE) ROOF-MOUNTED EXHAUST FAN CEILING-MOUNTED EXHAUST FAN CARBON DIOXIDE SENSOR AT ROOF AT CEILING EXHAUST GRILLE W/ TYPE AND CFM H HUMIDITY SENSOR T THERMOSTAT F&T GENERAL DUTY VALVES & FITTINGS EXPANSION LOOP (SIZE INDICATED ON DRAWINGS) CONCENTRIC REDUCER ECCENTRIC REDUCER PRESSURE REDUCING VALVE STEAM TRAP W/DESIGNATION GAS COCK PETE'S PLUG PIPE EXPANSION JOINT FLEXIBLE PIPING CONNECTOR Y-STRAINER W/BLOWDOWN VALVE & CAP PIPE ANCHORS PIPE GUIDES THERMOMETER WELL AUTOMATIC AIR VENT GAUGE CONNECTION(S) & WELL THERMOMETER & WELL MANUAL AIR VENT AUTOMATIC BALANCING VALVE TWO-WAY CONTROL VALVE THREE-WAY CONTROL VALVE UNION MANUAL BALANCING VALVE VALVE IN RISER ANGLE VALVE PLUG VALVE TRIPLE DUTY VALVE PRESSURE REGULATING VALVE BUTTERFLY VALVE RELIEF VALVE VALVE - SEE SPECIFICATIONS FOR VALVE TYPE PIPE CONTINUED ON ANOTHER DRAWING CHECK VALVE CAPPED PIPE RISE IN PIPING DROP IN PIPING GATE VALVE BALL VALVE DUCTWORK SYSTEMS EXHAUST AIR EXHAUST/RELIEF AIR KITCHEN EXHAUST AIR OUTSIDE AIR RELIEF AIR RETURN AIR SUPPLY AIR TRANSFER AIR EA EA/RL KEA OA RLA RA SA TA CHILLED WATER RETURN CHILLED WATER SUPPLY CONDENSATE DRAIN CONDENSER WATER RETURN CONDENSER WATER SUPPLY HEAT PUMP RETURN HEAT PUMP SUPPLY HEATING HOT WATER RETURN HEATING HOT WATER SUPPLY HIGH PRESSURE STEAM RETURN HIGH PRESSURE STEAM SUPPLY LOW PRESSURE STEAM RETURN LOW PRESSURE STEAM SUPPLY MEDIUM PRESSURE STEAM RETURN MEDIUM PRESSURE STEAM SUPPLY REFRIGERANT RETURN REFRIGERANT SUPPLY REFRIGERANT SUCTION GAS RETURN STEAM CONDENSATE PUMP DISCHARGE STEAM VENT CHWR CHWS CD CWR CWS HPR HPS HHWR HHWS HPSR HPSS LPSR LPSS MPSR MPSS RR RS RSGR CPD SV PIPING SYSTEMS DUCTWORK SYMBOLS MANUAL VOLUME DAMPER SHOETAP (OR 45° ENTRY) FITTING BELLMOUTH FITTING 45° LATERAL FITTING 90° TEE FITTING SHOETAP WITH SQUARE TO ROUND TRANSITION DUCT TRANSITION CONICAL FITTING 90° ELBOW WITH TURNING VANES STANDARD RADIUS ELBOW, CENTER RADIUS INSULATED FLEXIBLE DUCTWORK OFFSET IN DUCTWORK (R = RISE D = DROP) RECTANGULAR DUCTWORK ROUND SPIRAL DUCTWORK OVAL DUCTWORK DROP IN DUCTWORK (EXHAUST, RETURN, ETC.) RISE IN DUCTWORK (EXHAUST, RETURN, ETC.) RISE IN DUCTWORK (SUPPLY ONLY) DROP IN DUCTWORK (SUPPLY ONLY) 1-1/2 TIMES WIDTH OF DUCT 12"x8"ϴ 12"Ø 12"x8" R D BLADE DAMPER PBD = PARALLEL BLADE DAMPER DUCT-MOUNTED REHEAT COIL (HYDRONIC) NEW TO EXISTING INTERNALLY INSULATED DUCTWORK FLEXIBLE CONNECTION ACCESS DOOR MOTORIZED CONTROL DAMPER BDD = BACKDRAFT DAMPER OBD = OPPOSED AIR FLOW 20° 30° M AD BDD BDD COUNTERBALANCED BACKDRAFT DAMPER AD MBDD MOTORIZED BACKDRAFT DAMPER FD-(A/B) AD FSD AD SD AD FD-(A/B) = FIRE DAMPER (TYPE A OR TYPE B) FSD = FIRE/SMOKE DAMPER SD = SMOKE DAMPER 2 M-301 3 M-501 SECTION REFERENCE DETAIL REFERENCE PLAN NOTE DRAWING NOTATIONS NOTE: ALL SYMBOLS AND ABBREVIATIONS MAY NOT BE USED FOR THIS PROJECT 1 DEMO 1 NEW NEW TO EXISTING DEMO TO THIS POINT EQUIPMENT TAG - (SEE SCHEDULE SHEETS) DIFFUSER, REGISTER, GRILLE TAG - (SEE SCHEDULE SHEETS) SD24-12 300 XXX-1 CFM MARK N 6 5 4 3 2 1 A B C D E 6 5 4 3 2 1 A B C D E Project No. Project Date Produced These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect. KEY PLAN B A 5/22/2023 12:48:28 PM C:\_RevitLocal\2023-067.POR_Bldg001_M_2023\2023-067.POR_Bldg001_M_2023_tkennedy.rvt 2023-067.POR 05.22.2023 MECHANICAL SYMBOLS AND ABBREVIATIONS M-001 Designer Author Coram Deo Academy Phase One Renovations 2023-067.POR_Coram Deo Academy_Phase One Renovations_ 525 Congressional Blvd, Carmel, IN 46032 M-001_ MECHANICAL SYMBOLS AND ABBREVIATIONS # Revision Date COUNTERTOP. 6" CHASE DEPTH BEHIND CABINETS IS TO BE MAINTAINED. 24" D. 2 DR. BASE CABINET, TYP. 24" D. 2 DR SINK BASE, TYP. 8' - 0" 2' - 10" 1' - 8" 3' - 0" 2' - 6" 3' - 0" 3' - 6" CORNER 14" D. +/- CORNER CABINET W/ADJ. SHELVES. 3' - 6" 3' - 0" 4' - 0" REFERENCE ARCHITECTURAL PLAN NOTES #13 AND #14 FOR DETAILS REGARDING WALL PADS. 4" 3' - 8" WALL TO RECEIVE VINYL WALL BASE, VWB-1, TO MATCH EXISTING. TYP. 2' - 0" MB10 EXISTING VISUAL DISPLAYS TO REMAIN AS-IS. MARKERBOARD TO BE RELOCATED FROM OTHER ROOM IN THE BUILDING. MOBILE TEACHER DEMO STATION, TO BE INCLUDED IN CONTRACT. BASIS-OF-DESIGN: DIVERSIFIED WOODCRAFTS KINETIC MOBILE DEMO TABLE WITH SINK AND STORAGE, #4332K TYP. 4' - 0" TYP. 8' - 0" WALL TO RECEIVE RIGID WALL PROTECTION. BASIS- OF-DESIGN: ACROVYN 4' x 8' SHEETS DIRECT-GLUED TO WALL. COLOR: DRIFTWOOD #262 BREAK INDICATES SEAM; TO BE BUTT-JOINTED. REF. "E" SERIES DRWGS FOR COORDINATION OF SWITCHES/CONTROLS. WHERE THERE IS A CONFLICT, WALL PROTECTION IS TO BE CUT-OUT TO ALLOW FORSWITCH/CONTROL. 4" 3' - 8" WALL TO RECEIVE VINYL WALL BASE, VWB-1, TYP. WALL TO RECEIVE RIGID WALL PROTECTION. BASIS- OF-DESIGN: ACROVYN 4' x 8' SHEETS DIRECT-GLUED TO WALL. COLOR: DRIFTWOOD #262 BREAK INDICATES SEAM; TO BE BUTT-JOINTED. TYP. 8' - 0" TYP. 4' - 0" REF. "E" SERIES DRWGS FOR COORDINATION OF SWITCHES/CONTROLS. WHERE THERE IS A CONFLICT, WALL PROTECTION IS TO BE CUT-OUT TO ALLOW FORSWITCH/CONTROL. WALL TO RECEIVE RIGID WALL PROTECTION. BASIS- OF-DESIGN: ACROVYN 4' x 8' SHEETS DIRECT-GLUED TO WALL. COLOR: DRIFTWOOD #262 BREAK INDICATES SEAM; TO BE BUTT-JOINTED. TYP. 8' - 0" TYP. 4' - 0" REF. "E" SERIES DRWGS FOR COORDINATION OF SWITCHES/CONTROLS. WHERE THERE IS A CONFLICT, WALL PROTECTION IS TO BE CUT-OUT TO ALLOW FORSWITCH/CONTROL. WALL TO RECEIVE RIGID WALL PROTECTION. BASIS- OF-DESIGN: ACROVYN 4' x 8' SHEETS DIRECT-GLUED TO WALL. COLOR: DRIFTWOOD #262 BREAK INDICATES SEAM; TO BE BUTT-JOINTED. TYP. 8' - 0" TYP. 4' - 0" REF. "E" SERIES DRWGS FOR COORDINATION OF SWITCHES/CONTROLS. WHERE THERE IS A CONFLICT, WALL PROTECTION IS TO BE CUT-OUT TO ALLOW FORSWITCH/CONTROL. 3' - 0". 1' - 6". 2' - 6" 1' - 0" 2' - 1" 1". 3". 2' - 0" 2' - 7 3/4" 3/4" WHITE MELAMINE ADJUSTABLE SHELF. COUNTERTOP W/ 4" BACKSPLASH. ALL EXPOSED SURFACES TO BE EPOXY. NOTES: 1. PLASTIC LAMINATE MILLWORK, TYPICAL. PROVIDE PLASTIC LAMINATE ON ALL EXPOSED SURFACES. INTERIORS TO BE WHITE MELAMINE. 2. PROVIDE WOOD BLOCKING AS REQUIRED. 3. PROVIDE SELF EDGE ALONG EXPOSED EDGES (FRONT AND SIDES) OF COUNTERTOP. 4. HARDWARE AS SELECTED. REFER TO CABINETRY ELEVATIONS. 5. SECTION SHOWN FOR REFERENCE ONLY. PROVIDE PLASTIC LAMINATE TOEKICK TO MATCH ALL ADJACENT CABINET FINISHES BASE CABINETRY. ALL EXPOSED SURFACES TO BE PLASTIC LAMINATE. FINISH FACE OF WALL 3/4" WHITE MELAMINE ADJUSTABLE SHELF. UPPER CABINETRY. ALL EXPOSED SURFACES TO BE PLASTIC LAMINATE. 6 INCH UTILITY CHASE. 7' - 0" DOORS TO HAVE GLASS OR PLEXI-GLASS FRONTS. 2' - 1" 1". FULL-EXTENSION DRAWER GLIDES, TYP. 3' - 0'. 2' - 0" 3". 0' - 4" COUNTERTOP W/ 4" BACKSPLASH. ALL EXPOSED SURFACES TO EPOXY. NOTES: 1. PLASTIC LAMINATE MILLWORK, TYPICAL. PROVIDE PLASTIC LAMINATE ON ALL EXPOSED SURFACES. INTERIORS TO BE WHITE MELAMINE. 2. PROVIDE WOOD BLOCKING AS REQUIRED. 3. PROVIDE SELF EDGE ALONG EXPOSED EDGES (FRONT AND SIDES) OF COUNTERTOP. 4. HARDWARE AS SELECTED. REFER TO CABINETRY ELEVATIONS. 5. SECTION SHOWN FOR REFERENCE ONLY. PROVIDE PLASTIC LAMINATE TOEKICK TO MATCH ALL ADJACENT CABINET FINISHES BASE CABINETRY. ALL EXPOSED SURFACES TO BE PLASTIC LAMINATE. FINISH FACE OF WALL 6 INCH UTILITY CHASE. N 6 5 4 3 2 1 A B C D E 6 5 4 3 2 1 A B C D E Project No. Project Date Produced These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect. KEY PLAN B A 5/22/2023 3:25:21 PM C:\_RevitLocal\2023-067.POR_Bldg001_A_2023\2023-067.POR_Bldg001_A_2023_kroche.rvt 2023-067.POR 05.22.2023 INTERIOR ELEVATIONS & DETAILS I-201 KER Coram Deo Academy Phase One Renovations 2023-067.POR_Coram Deo Academy_Phase One Renovations_ 525 Congressional Blvd, Carmel, IN 46032 I-201_ INTERIOR ELEVATIONS & DETAILS 2C 1/4" = 1'-0" SCIENCE A121 - ELEVATION 1 2E 1/4" = 1'-0" SCIENCE A121 - ELEVATION 2 2A 1/4" = 1'-0" GYM A110 - SOUTH WALL ELEVATION CASEWORK: PL-1 COUNTERTOP: EPOXY 2D 1/4" = 1'-0" SCIENCE A121 - VISUAL DISPLAY CASEWORK: PL-1 COUNTERTOP: EPOXY 2B 1/4" = 1'-0" GYM A110 - TYP. WALL PROTECTION (WEST WALL) # Revision Date 5C 1/4" = 1'-0" GYM A110 - NORTH WALL ELEVATION 5B 1/4" = 1'-0" GYM A110 - EAST WALL ELEVATION 5A 1/4" = 1'-0" GYM A110 - ANGLED WALL ELEVATION DIVERSIFIED WOODCRAFTS MODEL #4332K SHOWN FOR REFERENCE. 4D 3/4" = 1'-0" TYPICAL CASEWORK - BASE 2 DR AND WALL CABINET 5D 3/4" = 1'-0" TYPICAL CASEWORK - 4 DRAWER 01 CAFETERIA B111A WALL:ETR FLOOR:LVT-1 BASE:VWB-1 07 CHAPEL B111 WALL:ETR FLOOR:ETR BASE:ETR CLASSROOM B120 CLASSROOM B110 STORAGE B112 OFFICE B108 KITCHENETTE B122 VESTIBULE B111B CORRIDOR B001 PARENT ROOM B100 COPIER B109 CLASSROOM B136 CLASSROOM B118 CLASSROOM B119 STORAGE B146A WOMENS RR B148 MENS RR B149 RR B134 PLUMBING B123 IDF B129 STORAGE B139 STORAGE B140 STORAGE B142 STORAGE B143 STORAGE B144 STORAGE B129A STORAGE B129B OFFICE B147 OFFICE B119A OFFICE B124 KITCHEN B128 KITCHENETTE B133 WALL:ETR/P-1 FLOOR:ETR BASE:ETR STORAGE B146 03 01 18 11 11 11 11 11 19 25 25 ALIGN ALIGN TYP. 4' - 0" TYP. 4' - 0". A. B. C. D. E. F. G. H. I. J. K. INTERIOR GENERAL NOTES FINISHES PRIOR TO START & FINAL COMPLETION OF WORK • Where existing finishes are to remain outside scope of work, patch & repair any area damaged or effected by renovation, to return to like new condition, matching adjacent finishes. This includes, but is not limited to doors & associated hardware, door frames, wall finishes, wall base, floor finish including floor transitions & thresholds, etc. It is the responsibility of the contractor to verify conditions in field prior to start & completion of work. Interior Painting/Wallcovering • Existing wall conditions that were not specifically noted to be patched and repaired, but are designated to receive new finishes, are to be repaired prior to new finishes being applied. It is the Contractors responsibility to confirm conditions in field prior to start of work. • Vinyl Wall Base over gyp. - Prior to removal of existing vinyl wall base, score wall above top of base to minimize damage to drywall. Reference architectural ceilings plans for ceiling heights and bulkhead color designations. Paint all bulkheads HP-1 or P-1 (neutral to match existing) unless specifically noted otherwise. Bulkheads that are flush with walls provide color to match adjacent wall color. Paint interior hollow metal door frames high performance (HP) paint to match existing. Paint all exposed conduit, piping, and associated assemblies to match adjacent paint finish. Applies to all new & existing to remain in areas of renovation or new construction. Paint general walls HP-1 or P-1 (Neutral to match existing) unless specifically noted otherwise, only in areas that have been affected by demolition. Wall Base 1. Install vinyl wall base on top of rigid wall protection. Provide caulk joint at floor level, typ. 2. Provide vinyl wall base around all casework unless specicially noted otherwise 3. Provide new vinyl wall base to match existing on new wall construction. Where floor finish transitions between rooms, align transition centered with threshold of door unless noted otherwise. 1. LVT to carpet does not require transition strip, products will abutt at same height. Science classroom: epoxy top student tables, stools, mobile teacher demo station, and chemical storage units are included in this contract. Appliances and vending equipment are not provided in this contract. Visual display boards (marker and tack boards) to be mounted at 3' - 0" A.F.F. Interior Floor Pattern Legend RF-1 Resilient Sheet Flooring LVT-1 (12" X 24") Luxury Vinyl Tile RF-2 LVT-2 (12" X 24") N 6 5 4 3 2 1 A B C D E 6 5 4 3 2 1 A B C D E Project No. Project Date Produced These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect. KEY PLAN B A 5/22/2023 3:25:18 PM C:\_RevitLocal\2023-067.POR_Bldg001_A_2023\2023-067.POR_Bldg001_A_2023_kroche.rvt 2023-067.POR 05.22.2023 FIRST FLOOR INTERIOR FINISH PLAN IN1B1 KER Coram Deo Academy Phase One Renovations 2023-067.POR_Coram Deo Academy_Phase One Renovations_ 525 Congressional Blvd, Carmel, IN 46032 IN1B1_ FIRST FLOOR INTERIOR FINISH PLAN 1A 1/8" = 1'-0" FIRST FLOOR INTERIOR FLOOR PLAN - UNIT B 5.5.100 - INTERIOR FINISH LEGEND MARK DESCRIPTION MANUFACTURE R COLLECTION/PA TTERN COLOR COMMENTS FLOORING LVT-1 LUXURY VINYL TILE MOHAWK GROUP LIVING LOCAL/TERRAZZO VESUVIUS 723 SIZE: 12 BY 24 INCHES; INSTALL: BRICK ASHLAR; INSTALLED IN CAFETERIA AS ALT. LVT-2 LUXURY VINYL TILE MOHAWK GROUP LIVING LOCAL/CHROMASCOPE FIRETRUCK RED 550 SIZE: 12 BY 24 INCHES; INSTALL: BRICK ASHLAR; INSTALLED IN CAFETERIA AS ALT. RF-1 RUBBER SHEET FLOORING MANNINGTON COLORFIELDS SONIC 896 SIZE: 4 BY 50 FEET; INSTALL: HEAT WELDED SEAMS WITH 4 INCH INTEGRAL COVE BASE. RF-2 RUBBER SHEET FLOORING MANNINGTON COLORFIELDS CUMULUS 884 SIZE: 4 BY 50 FEET; INSTALL: HEAT WELDED SEAMS WITH 4 INCH INTEGRAL COVE BASE. VWB-1 VINYL WALL BASE FLEXCO -- SIZE: 4" COVE BASE IN COIL FORM. VCT-1 VINYL COMPOSITION TILE ARMSTRONG FLOORING PREMIUM EXCELON/CROWN TEXTURE 5C908 PEWTER SIZE: 12 BY 12 INCHES; INSTALL: MONOLITHIC; INSTALLED IN CAFETERIA AS BASE BID ONLY. FURNISHINGS RWS-1 ROLLER WINDOW SHADES DRAPER 3% OPENNESS MATCH EXISTING LOCATION(S): ALL EXTERIOR CLASSROOM WINDOWS THAT DO NOT ALREADY HAVE SHADES INSTALLED. PL-1 PLASTIC LAMINATE PIONITE TEXTURED/SUEDE OLD FRIEND AG415-SD LOCATION(S): SCIENCE PERIMETER CASEWORK WALLS P-1 PAINT (FIELD) SHERWIN WILLIAMS -- MATCH EXISTING (GENERAL NEUTRAL) LOCATION(S): WHERE INDICATED P-2 PAINT (ACCENT) SHERWIN WILLIAMS -- BOLERO SW7600 LOCATION(S): WHERE INDICATED HP-1 HIGH PERFORMANCE PAINT SHERWIN WILLIAMS -- MATCH EXISTING DOOR FRAMES AND RAILINGS FLOOR PLAN NOTES # Note 01 ALIGN FACE OF NEW WALL/INFILL WITH ADJACENT WALL FACE. 02 INFILL OPENING WITH WALL TO MATCH SURROUNDING/ADJACENT WALL CONSTRUCTION. VERIFY EXISTING WALL CONDITIONS/CONSTRUCTION AND DIMENSIONS IN THE FIELD. ALIGN THE FACE OF THE NEW INFILL WALL WITH THE ADJACENT EXISTING WALL FACE. 03 INTERIOR WOODFRAMED WINDOW WITH GLAZING. REF A-600 FOR SIZE AND DETAILS 04 RELOCATED EXISTING DOOR AND FRAME, REF A-600 SERIES FOR SIZE AND TYPE. 05 BASE BID: EXISTING FLOORING TO REMAIN; PATCH AREAS AFFECTED BY DEMOLITION WITH SALVAGED OR NEW TO MATCH EXISTING CARPET TILE. SCIENCE LAB ALTERNATE: SCIENCE LAB EQUIPMENT, CASEWORK AND RESILIENT SHEET FLOORING AS SHOWN. 06 NEW DOOR IN EXISTING FRAME WITH NEW CONTINUOUS ALUMINUM HINGE. REF DOOR SCHEDULE FOR SIZE. VERIFY IN FIELD. 07 REATTACH EXISTING RAILING TO EXISTING CONCRETE STAIR; REF DETAILS 08 GYMNASIUM WALL PADS, 2' L X 4' H. WRAP ALL OUTSIDE CORNERS AND EDGES TO CREATE A CONTINUOUS RUN. 09 RUBBER TILE USED FOR INFILL POST DEMOLITION ARE TO MATCH EXISTING. 10 FOLLOWING DEMOLITION, FLOORING ON GROUND IS TO BE VINYL COMPOSITION TILE, VCT. VCT IS TO ABUTT TO EXISTING VCT AND IS TO MATCH EXISTING. 11 AREAS AFFECTED BY DEMOLITION ARE TO RECEIVE CARPET TILE. CARPET TILES ARE TO MATCH EXISTING 12 EYEWASH STATION; REF P-SERIES DWGS. 13 BASE BID: GYMNASIUM WALL PADS BELOW SILL. GYMNASIUM WALL ALTERNATE: NEW WALL CONSTRUCTION IN FRONT OF EXISTING WINDOWS; REF SECTION DETAILS. 14 WRAP CORNER WITH GYMNASIUM WALL PADS; TERMINATE AT FACE OF EXISTING STOREFRONT. 15 NEW UTILITY SINK- REF P-DWGS 16 BASE BID: EXISTING DOOR AND FRAME TO REMAIN. MUSIC DOOR ALTERNATE: RELOCATED DOOR AND NEW WALL CONSTRUCTION AS SHOWN. REF DOOR SCHEDULE FOR SIZE AND TYPE 17 BASE BID: EXISTING DOOR TO REMAIN. SCIENCE LAB ALTERNATE: REMOVE EXISTING DOOR AND APPLY PLAN NOTE 2. 18 FOLLOWING DEMOLITION, FLOORING ON GROUND IS TO BE CARPET TILE, CPT-1 (MATCH EXISTING). EXISTING VCT IS TO BE DEMOLISHED OR COVERED WITH CPT-1. 19 EXISTING FLOORING FINISH ON RISERS AND FABRIC-WRAPPED WALL PANELS ARE TO BE EXISTING TO REMAIN. 20 WALL TO RECEIVE PAINT, P-2, INSIDE CORNER TO INSIDE CORNER. 21 BASE BID: 4 OFFICES COMBINED INTO 1 SPACE, REF DEMOLITION PLANS. ROOM B137 ALTERNATE: NEW WALL CONSTRUCTION AS SHOWN. 22 RELOCATED FIRE PANEL. COORDINATE FINAL LOCATION WITH OWNER IN FIELD. 23 SCIENCE LAB ALTERNATE: NEW DRYWALL ON EXISTING STUD TO DECK, BOTH SIDES OF THE WALL. REF WALL SECTIONS AND DETAILS. 24 PATCH AND REPAIR EXISTING GWB TO CREATE A SEAMLESS, SMOOTH TRANSITION. PREP FOR FINISH 25 NEW FLOORING (LVT) TO ALIGN WITH NEW BULKHEADS. 26 MECHANICAL HOOD. BASIS OF DESIGN ELIMINATOR 500 SERIES ADA DESIGN. PART # EH-511-72.INCLUDE (1) CORROSIVE AND (1) FLAMMABLE BASE CABINET BELOW. REF M-SERIES DWGS 27 NEW DOOR CLOSER ON EXISTING DOOR. BASIS OF DESIGN LCN 1250 SERIES. 28 NEW STAINLESS STEEL KICK PLATE MOUNED TO FACE OF ALUMINUM EXTERIOR DOOR. EXTEND MIN 1" BEYOND EDGE OF GLASS IN DOOR AND TO BOTTOM OF EXIT DEVICE. ATTACH WITH COMPATIBLE METAL SCREWS INSTALLED IN FOAM GASKET; COUNTERINK ALL HOLES IN EXISTING DOOR. SEPARATE DISSIMILAR METALS WITH NON CORROSIVE MATERIALS. FIELD VERIFY. # Revision Date A110C CORRIDOR A002 STORAGE A110A CLASSROOM A116 WALL:ETR FLOOR:ETR BASE:ETR CLASSROOM A120 WALL:ETR FLOOR:ETR BASE:ETR SCIENCE LAB A121 WALL:P-1,2 FLOOR:RF-1,2 BASE:RFB-1,2 CLASSROOM A118 OFFICE A119 01 04 CAFETERIA B111A 08 CLASSROOM B120 CLASSROOM B110 CLASSROOM A113 STORAGE B112 STORAGE A112 STORAGE A111 STORAGE A117 BREAK ROOM A106 PRACTICE ROOM B117A PRACTICE ROOM B116 PRACTICE ROOM B114 PRACTICE ROOM B113 WOMENS RR B104 WOMENS RR A108 MENS RR A109 MENS RR B103 ELECTRICAL A112A UNOCCUPIED A130 UNOCCUPIED A129 UNOCCUPIED A128 UNOCCUPIED A127 UNOCCUPIED A126 UNOCCUPIED A125 UNOCCUPIED A124 UNOCCUPIED A123 UNOCCUPIED A122 STORAGE A106A STORAGE B102 STORAGE A103A JANITOR A107 RISER RM A108A OFFICE A102 OFFICE A103 OFFICE A104 OFFICE B105 OFFICE B106 OFFICE B107 OFFICE B108 OFFICE B115A STORAGE B115B STORAGE B115C OFFICE A105 VESTIBULE A110B VESTIBULE A100A VESTIBULE B111B CORRIDOR A003 CORRIDOR A001 VESTIBULE A003A CLINIC A101 PARENT ROOM B100 COPIER B109 LOBBY A100 VESTIBULE A003B STORAGE B101 OFFICE A115 OFFICE A114 PRACTICE ROOM B114 LOBBY A100 09 11 11 12 13 14 14 15 11 EQ. EQ. 05 06 17 12" MIN CLR. MB10 20 2B 5C 5B I-201 5A 4 3/4" Interior Floor Pattern Legend RF-1 Resilient Sheet Flooring LVT-1 (12" X 24") Luxury Vinyl Tile RF-2 LVT-2 (12" X 24") N 6 5 4 3 2 1 A B C D E 6 5 4 3 2 1 A B C D E Project No. Project Date Produced These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect. KEY PLAN B A 5/22/2023 3:25:17 PM C:\_RevitLocal\2023-067.POR_Bldg001_A_2023\2023-067.POR_Bldg001_A_2023_kroche.rvt 2023-067.POR 05.22.2023 FIRST FLOOR INTERIOR FINISH PLAN IN1A1 KER Coram Deo Academy Phase One Renovations 2023-067.POR_Coram Deo Academy_Phase One Renovations_ 525 Congressional Blvd, Carmel, IN 46032 IN1A1_ FIRST FLOOR INTERIOR FINISH PLAN 5.5.100 - INTERIOR FINISH LEGEND MARK DESCRIPTION MANUFACTURE R COLLECTION/PA TTERN COLOR COMMENTS FLOORING LVT-1 LUXURY VINYL TILE MOHAWK GROUP LIVING LOCAL/TERRAZZO VESUVIUS 723 SIZE: 12 BY 24 INCHES; INSTALL: BRICK ASHLAR; INSTALLED IN CAFETERIA AS ALT. LVT-2 LUXURY VINYL TILE MOHAWK GROUP LIVING LOCAL/CHROMASCOPE FIRETRUCK RED 550 SIZE: 12 BY 24 INCHES; INSTALL: BRICK ASHLAR; INSTALLED IN CAFETERIA AS ALT. RF-1 RUBBER SHEET FLOORING MANNINGTON COLORFIELDS SONIC 896 SIZE: 4 BY 50 FEET; INSTALL: HEAT WELDED SEAMS WITH 4 INCH INTEGRAL COVE BASE. RF-2 RUBBER SHEET FLOORING MANNINGTON COLORFIELDS CUMULUS 884 SIZE: 4 BY 50 FEET; INSTALL: HEAT WELDED SEAMS WITH 4 INCH INTEGRAL COVE BASE. VWB-1 VINYL WALL BASE FLEXCO -- SIZE: 4" COVE BASE IN COIL FORM. VCT-1 VINYL COMPOSITION TILE ARMSTRONG FLOORING PREMIUM EXCELON/CROWN TEXTURE 5C908 PEWTER SIZE: 12 BY 12 INCHES; INSTALL: MONOLITHIC; INSTALLED IN CAFETERIA AS BASE BID ONLY. FURNISHINGS RWS-1 ROLLER WINDOW SHADES DRAPER 3% OPENNESS MATCH EXISTING LOCATION(S): ALL EXTERIOR CLASSROOM WINDOWS THAT DO NOT ALREADY HAVE SHADES INSTALLED. PL-1 PLASTIC LAMINATE PIONITE TEXTURED/SUEDE OLD FRIEND AG415-SD LOCATION(S): SCIENCE PERIMETER CASEWORK WALLS P-1 PAINT (FIELD) SHERWIN WILLIAMS -- MATCH EXISTING (GENERAL NEUTRAL) LOCATION(S): WHERE INDICATED P-2 PAINT (ACCENT) SHERWIN WILLIAMS -- BOLERO SW7600 LOCATION(S): WHERE INDICATED HP-1 HIGH PERFORMANCE PAINT SHERWIN WILLIAMS -- MATCH EXISTING DOOR FRAMES AND RAILINGS FLOOR PLAN NOTES # Note 01 ALIGN FACE OF NEW WALL/INFILL WITH ADJACENT WALL FACE. 02 INFILL OPENING WITH WALL TO MATCH SURROUNDING/ADJACENT WALL CONSTRUCTION. VERIFY EXISTING WALL CONDITIONS/CONSTRUCTION AND DIMENSIONS IN THE FIELD. ALIGN THE FACE OF THE NEW INFILL WALL WITH THE ADJACENT EXISTING WALL FACE. 03 INTERIOR WOODFRAMED WINDOW WITH GLAZING. REF A-600 FOR SIZE AND DETAILS 04 RELOCATED EXISTING DOOR AND FRAME, REF A-600 SERIES FOR SIZE AND TYPE. 05 BASE BID: EXISTING FLOORING TO REMAIN; PATCH AREAS AFFECTED BY DEMOLITION WITH SALVAGED OR NEW TO MATCH EXISTING CARPET TILE. SCIENCE LAB ALTERNATE: SCIENCE LAB EQUIPMENT, CASEWORK AND RESILIENT SHEET FLOORING AS SHOWN. 06 NEW DOOR IN EXISTING FRAME WITH NEW CONTINUOUS ALUMINUM HINGE. REF DOOR SCHEDULE FOR SIZE. VERIFY IN FIELD. 07 REATTACH EXISTING RAILING TO EXISTING CONCRETE STAIR; REF DETAILS 08 GYMNASIUM WALL PADS, 2' L X 4' H. WRAP ALL OUTSIDE CORNERS AND EDGES TO CREATE A CONTINUOUS RUN. 09 RUBBER TILE USED FOR INFILL POST DEMOLITION ARE TO MATCH EXISTING. 10 FOLLOWING DEMOLITION, FLOORING ON GROUND IS TO BE VINYL COMPOSITION TILE, VCT. VCT IS TO ABUTT TO EXISTING VCT AND IS TO MATCH EXISTING. 11 AREAS AFFECTED BY DEMOLITION ARE TO RECEIVE CARPET TILE. CARPET TILES ARE TO MATCH EXISTING 12 EYEWASH STATION; REF P-SERIES DWGS. 13 BASE BID: GYMNASIUM WALL PADS BELOW SILL. GYMNASIUM WALL ALTERNATE: NEW WALL CONSTRUCTION IN FRONT OF EXISTING WINDOWS; REF SECTION DETAILS. 14 WRAP CORNER WITH GYMNASIUM WALL PADS; TERMINATE AT FACE OF EXISTING STOREFRONT. 15 NEW UTILITY SINK- REF P-DWGS 16 BASE BID: EXISTING DOOR AND FRAME TO REMAIN. MUSIC DOOR ALTERNATE: RELOCATED DOOR AND NEW WALL CONSTRUCTION AS SHOWN. REF DOOR SCHEDULE FOR SIZE AND TYPE 17 BASE BID: EXISTING DOOR TO REMAIN. SCIENCE LAB ALTERNATE: REMOVE EXISTING DOOR AND APPLY PLAN NOTE 2. 18 FOLLOWING DEMOLITION, FLOORING ON GROUND IS TO BE CARPET TILE, CPT-1 (MATCH EXISTING). EXISTING VCT IS TO BE DEMOLISHED OR COVERED WITH CPT-1. 19 EXISTING FLOORING FINISH ON RISERS AND FABRIC-WRAPPED WALL PANELS ARE TO BE EXISTING TO REMAIN. 20 WALL TO RECEIVE PAINT, P-2, INSIDE CORNER TO INSIDE CORNER. 21 BASE BID: 4 OFFICES COMBINED INTO 1 SPACE, REF DEMOLITION PLANS. ROOM B137 ALTERNATE: NEW WALL CONSTRUCTION AS SHOWN. 22 RELOCATED FIRE PANEL. COORDINATE FINAL LOCATION WITH OWNER IN FIELD. 23 SCIENCE LAB ALTERNATE: NEW DRYWALL ON EXISTING STUD TO DECK, BOTH SIDES OF THE WALL. REF WALL SECTIONS AND DETAILS. 24 PATCH AND REPAIR EXISTING GWB TO CREATE A SEAMLESS, SMOOTH TRANSITION. PREP FOR FINISH 25 NEW FLOORING (LVT) TO ALIGN WITH NEW BULKHEADS. 26 MECHANICAL HOOD. BASIS OF DESIGN ELIMINATOR 500 SERIES ADA DESIGN. PART # EH-511-72.INCLUDE (1) CORROSIVE AND (1) FLAMMABLE BASE CABINET BELOW. REF M-SERIES DWGS 27 NEW DOOR CLOSER ON EXISTING DOOR. BASIS OF DESIGN LCN 1250 SERIES. 28 NEW STAINLESS STEEL KICK PLATE MOUNED TO FACE OF ALUMINUM EXTERIOR DOOR. EXTEND MIN 1" BEYOND EDGE OF GLASS IN DOOR AND TO BOTTOM OF EXIT DEVICE. ATTACH WITH COMPATIBLE METAL SCREWS INSTALLED IN FOAM GASKET; COUNTERINK ALL HOLES IN EXISTING DOOR. SEPARATE DISSIMILAR METALS WITH NON CORROSIVE MATERIALS. FIELD VERIFY. 1A 1/8" = 1'-0" FIRST FLOOR INTERIOR FLOOR PLAN - UNIT A # Revision Date CUT CEILING PANELS AS REQUIRED FOR NEW WALL CONSTRUCTION. EXTEND GWB TO BOTTOM OF GRID 09 29 00.G1 - SOUND ATTENUATION BLANKET 09 29 00.B7 - INT GWB, 5/8" TYPE X 09 22 16.C6 - INT STEEL STUD FRAMING, 3-5/8" @ 16" O.C. EXISTING CEILING TO REMAIN. CUT CEILING PANELS AS REQUIRED FOR NEW WALL CONSTRUCTION. EXTEND GWB TO BOTTOM OF GRID PLANS SEE 09 29 00.B7 - INT GWB, 5/8" TYPE X 09 22 16.C10 - METAL STUD BOX BEAM 07 92 00.B3 - JOINT SEALANT (BOTH SIDES) 08 11 13.A1 - DOOR & FRAME, REF DOOR SCHEDULE 1/2" 1/2" PLANS SEE 09 29 00.B7 - INT GWB, 5/8" TYPE X 09 22 16.C11 - DOUBLE STUDS 07 92 00.B3 - JOINT SEALANT (BOTH SIDES) 08 11 13.A1 - DOOR & FRAME, REF DOOR SCHEDULE 1/2" 1/2" 34" MIN. TO 38" MAX. 34" MIN. TO 38" MAX. 34" MIN. TO 38" MAX. EXISTING PIPE HANDRAIL TO BE REMOVED, REPAIRED, AND REATTACHED TO EXISTING EXTERIOR STAIR. FIELD VERIFY ALL CONDITIONS. REMOVE DAMAGED PORTION OF RAIL BEFORE REINSTALLATION. WELD TO NEW FLANGE ATTACHMENT AND BOLT TO EXISTING STAIR. RAILINGS SHALL WITHSTAND THE EFFECTS OF GRAVITY LOADS AND THE FOLLOWING LOADS AND STRESSES WITHIN LIMITS NAD UNDER CONDITIONS INDICATED: HANDRAILS AND TOP RAILS OF GUARDS: UNIFORM LOAD OF 50 LBF/FT APPLIED IN ANY DIRECTION AND CONCENTRATED LOAD OF 200 LBF APPLIED IN ANY DIRECTION. INFILL OF GUARDS: CONCENTRATED LOAD OF 50 LBF APPLIED HORIZONTALLY ON AN AREA OF 1 SQ. FT. UNIFORM, CONCENTRATED, AND INFILL LOADS NEED NOT BE ASSUMED TO ACT CONCURRENTLY REMOVE EXISTING METAL FINISH AND PREP FOR NEW HIGH PERFORMANCE COATING SYSTEM. PROVIDE SHOP AND FIELD PRIMERS, AND FINISH- COAT MATERIALS THAT ARE COMPATIBLE WITH EACH OTHER AND WITH EXISTING SUBSTRATE UNDER CONDITIONS OF SERVICE AND APPLICATION, AS DEMONSTRATED BY MANUFACTURER BASED ON TESTING AND FIELD EXPERIENCE EXISTING CONCRETE STAIR, V.I.F. PLANS SEE 09 22 16.C10 - METAL STUD BOX BEAM 07 92 00.B3 - JOINT SEALANT (BOTH SIDES) 08 11 13.A1 - DOOR & FRAME, REF DOOR SCHEDULE 1/2" 1/2" MATCH EXISTING ADJACENT WALL CONSTRUCTION AND FINISH. PATCH TO CREATE SEAMLESS TRANSITION FROM EXISTING TO NEW MATERIAL. PLANS SEE 09 22 16.C11 - DOUBLE STUDS 07 92 00.B3 - JOINT SEALANT (BOTH SIDES) 08 11 13.A1 - DOOR & FRAME, REF DOOR SCHEDULE 1/2" 1/2" MATCH EXISTING ADJACENT WALL CONSTRUCTION AND FINISH. PATCH TO CREATE SEAMLESS TRANSITION FROM EXISTING TO NEW MATERIAL. PLANS SEE 09 29 00.B7 - INT GWB, 5/8" TYPE X 09 22 16.C10 - METAL STUD BOX BEAM 07 92 00.B3 - JOINT SEALANT (BOTH SIDES) EQ EQ SALVAGED INTERIOR GLASS PANE. ALL GLASS WITHIN 18" A.F.F. SHALL BE SAFETY GLAZING 06 40 23 - 1X FINISHED WOOD TRIM. EXTEND LESS THAN 1/2" BEYOND FACE OF ADJACENT WALL 06 10 53.B2 - WOOD BLOCKING, 2X CONTINUOUS 09 29 00 - GWB REVEAL, 3/4" BASIS OF DESIGN FRY REGLET DRMZ-625-75 PLANS SEE 09 29 00.B7 - INT GWB, 5/8" TYPE X 07 92 00.B3 - JOINT SEALANT (BOTH SIDES) EQ EQ SALVAGED INTERIOR GLASS PANE. ALL GLASS WITHIN 18" A.F.F. SHALL BE SAFETY GLAZING 06 40 23 - 1X FINISHED WOOD TRIM. EXTEND LESS THAN 1/2" BEYOND FACE OF ADJACENT WALL 06 10 53.B2 - WOOD BLOCKING, 2X CONTINUOUS 09 29 00 - GWB REVEAL, 3/4" BASIS OF DESIGN FRY REGLET DRMZ-625-75 09 22 16.C11 - DOUBLE STUDS 07 92 00.B3 - JOINT SEALANT (BOTH SIDES) SALVAGED INTERIOR GLASS PANE. ALL GLASS WITHIN 18" A.F.F. SHALL BE SAFETY GLAZING 06 40 23 - 1X FINISHED WOOD TRIM. EXTEND LESS THAN 1/2" BEYOND FACE OF ADJACENT WALL 06 40 23.K1 - 1X FINISHED WOOD TRIM CONSTRUCTION OR NO 2 GRADE 2X4 DIMENSIONAL LUMBER, ANY SPECIES. 4 1/4" EXISTING FLOOR CONSTRUCTION AND FINISH, V.I.F. RUBBER GASKET 09 29 00.B9 - INT GWB, 5/8" TYPE X EACH SIDE 09 22 16.C6 - INT STEEL STUD FRAMING, 3-5/8" @ 16" O.C. 09 22 16.C13 - DEFLECTION TRACK SECURE FRAMING TO DECK/STRUCTURE ABOVE Level 1 0' - 0" Level 1 0' - 0" Level 1 0' - 0" Level 1 0' - 0" SCIENCE LAB A121 BREAK ROOM A106 S4-D EXISTING WALL CONSTRUCTION, V.I.F. REMOVE EXISTING ACOUSTICAL CEILING AS REQUIRED FOR CONSTRUCTION. PATCH AND REPAIR CEILING TO CREATE A SEAMLES TRANSITION FROM EXISTING TO NEW CEILING. V.I.F. 10' - 8" V.I.F. 09 51 13.A2 - CEILING FINISH, REF ARCHITECTURAL CEILING PLANS NRIU DOOR & FRAME SCHEDULE MARK DOOR PANEL FRAME LABEL HDWR TYPE QTY MATL GLAZ SET NOTES MARK SIZE H W TH MARK MATL GLAZ A110.1 F 1 WD -- 7' - 0" 3' - 0" 0' - 1 3/4" F1 HM -- ETR 2 A110.1 A110.2 F 1 WD -- 7' - 0" 3' - 0" 0' - 1 3/4" F1 HM -- ETR 2 A110.2 A110.3 G 1 AL IG 7' - 0" 3' - 0" 0' - 1 3/4" EXIST EXIST EXIST ETR 1 A110.3 A110.4 F 1 WD -- 7' - 0" 3' - 0" 0' - 1 3/4" F1 WD -- ETR 2 A110.4 B126 F 1 WD -- 7' - 0" 3' - 0" 0' - 1 3/4" F2 HM TG ETR 2 B126 B130 F 1 WD -- 7' - 0" 3' - 0" 0' - 1 3/4" F2 HM TG ETR 2 B130 B137 F 1 WD -- 7' - 0" 3' - 0" 0' - 1 3/4" F2 HM TG ETR 2 B137 1/4" = 1'-0" 5.4.603 - FRAME ELEVATIONS 1/4" = 1'-0" 5.4.602 - DOOR PANEL ELEVATIONS N 6 5 4 3 2 1 A B C D E 6 5 4 3 2 1 A B C D E Project No. Project Date Produced These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect. KEY PLAN B A 5/22/2023 2:34:01 PM C:\_RevitLocal\2023-067.POR_Bldg001_A_2023\2023-067.POR_Bldg001_A_2023_mmiller.rvt 2023-067.POR 05.22.2023 SCHEDULES & DETAILS A-600 MW Coram Deo Academy Phase One Renovations 2023-067.POR_Coram Deo Academy_Phase One Renovations_ 525 Congressional Blvd, Carmel, IN 46032 A-600_ SCHEDULES & DETAILS 6E 1 1/2" = 1'-0" S4-C WALL TYPE 5E 1 1/2" = 1'-0" S4iC WALL TYPE 6D 1 1/2" = 1'-0" HEAD 6C 1 1/2" = 1'-0" JAMB 3A 1 1/2" = 1'-0" EXISTING RAIL ELEVATION 5D 1 1/2" = 1'-0" HEAD 5C 1 1/2" = 1'-0" JAMB 4E 1 1/2" = 1'-0" HEAD 4D 1 1/2" = 1'-0" JAMB 4C 1 1/2" = 1'-0" SILL 1A 3/4" = 1'-0" WALL SECTION @ SCIENCE LAB 6B 1 1/2" = 1'-0" S4-D WALL TYPE # Revision Date 5 5 A A 2 2 1 1 B B C C D D G G A5 A5 A4 A4 A3 A3 A2 A2 A1 A1 E.P E.P 5 A 1 2 B C D G A1 A2 A3 A4 A5 E.P 3 1 1 2 2 1 1 1 1 2 3 2 1 2 1 1 2 1 1 1 2 2 1 1 1 1 1 1 1 5 6 5 1' - 0" A.F.F. APC-1 10' - 0" A.F.F. GWB 9' - 10" A.F.F. GWB 9' - 10" A.F.F. GWB 9' - 10" A.F.F. GWB 9' - 10" 1' - 0" 8" 135.00° 7" 7 7 7 7 7 7 8 8 8 8 2 N 6 5 4 3 2 1 A B C D E 6 5 4 3 2 1 A B C D E Project No. Project Date Produced These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect. KEY PLAN B A 5/22/2023 2:33:49 PM C:\_RevitLocal\2023-067.POR_Bldg001_A_2023\2023-067.POR_Bldg001_A_2023_mmiller.rvt 2023-067.POR 05.22.2023 FIRST FLOOR REFLECTED CEILING PLAN - UNIT B AC1B1 MW Coram Deo Academy Phase One Renovations 2023-067.POR_Coram Deo Academy_Phase One Renovations_ 525 Congressional Blvd, Carmel, IN 46032 AC1B1_ FIRST FLOOR REFLECTED CEILING PLAN - UNIT B REFLECTED CEILING PLAN NOTES # NOTE 1 EXISTING CEILING TO REMAIN. MODIFY AS REQUIRED TO ACCOMMODATE NEW CONSTRUCTION 2 NEW GWB BULKHEAD 4" BELOW EXISTING CEILING. REF TYPICAL DETAILS. 3 NEW ACOUSTIC CEILING TILES TO MATCH APC-1 IN EXISTING GRID. REPAINT GRID WHITE, COLOR SELECTED BY ARCHITECT. 4 NOT USED 5 NEW CEILING GRID TO MATCH EXISTING ADJACENT CEILING. MATCH EXISTING CEILING HEIGHT AND TYPE. INTEGRATE NEW CEILING GRID INTO EXISTING GRID PATTERN. V.I.F. 6 BASE BID: EXISTING CEILINGS TO REMAIN; NEW GWB BULKHEAD 4" BELOW EXISTING ADJACENT CEILINGS. REF TYPICAL DETAILS. ROOM B137 ALTERNATE: NEW LAY-IN CEILING TO MATCH EXISTING ADJACENT CEILING HEIGHT AND CONFIGURATION. V.I.F. 7 ALIGN FACE OF BULKHEAD WITH FACE OF ADJACENT WALL 8 BULKHEAD TO RECEIVE PAINT, P-2, IN ITS ENTIRETY. 2A 1/8" = 1'-0" REFLECTED CEILING PLAN - UNIT B # Revision Date L F F G G A5 A5 E.P 5 E.P 6 7 8 4 9 A 2 1 B C D E 10 11 12 H J K L F G A5 E.P 1 1 2 1 1 2 1 1 1 1 2 A.F.F. APC-1 10' - 0" 5 5 1' - 0" A.F.F. APC-1 10' - 0" A.F.F. GWB 9' - 10" A.F.F. GWB 9' - 10" 1' - 0" 8" 135.00° 7" 7 7 7 1A A-600 8 8 REFLECTED CEILING PLAN LEGEND APC-1 2' X 2' Acoustical Panel Ceiling (09 51 13) GWB 5/8" GWB on Grid Suspension System (09 22 16) Walls to Deck Light Fixture (Reference E-Series Dwgs) Return Air (Reference M-Series Dwgs) Supply Air (Reference M-Series Dwgs) Exit Light (Reference E-Series Dwgs) Recessed Light Fixture Suspended Fixture in Areas with Exposed Ceilings (Reference E-Series Dwgs) S SOUND SYSTEM SPEAKER (REFERENCE E-SERIES/T- SERIES DWGS) 0' - 8" MIN. REF. PLANS 0' - 8" MIN. 09 29 00.B7 - INT GWB, 5/8" TYPE X 09 22 16.C6 - INT STEEL STUD FRAMING, 3-5/8" @ 16" O.C. 09 51 13.A2 - CEILING FINISH, REF ARCHITECTURAL CEILING PLANS REF. PLANS N 6 5 4 3 2 1 A B C D E 6 5 4 3 2 1 A B C D E Project No. Project Date Produced These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect. KEY PLAN B A 5/22/2023 2:33:36 PM C:\_RevitLocal\2023-067.POR_Bldg001_A_2023\2023-067.POR_Bldg001_A_2023_mmiller.rvt 2023-067.POR 05.22.2023 FIRST FLOOR REFLECTED CEILING PLAN - UNIT A AC1A1 MW Coram Deo Academy Phase One Renovations 2023-067.POR_Coram Deo Academy_Phase One Renovations_ 525 Congressional Blvd, Carmel, IN 46032 AC1A1_ FIRST FLOOR REFLECTED CEILING PLAN - UNIT A REFLECTED CEILING PLAN NOTES # NOTE 1 EXISTING CEILING TO REMAIN. MODIFY AS REQUIRED TO ACCOMMODATE NEW CONSTRUCTION 2 NEW GWB BULKHEAD 4" BELOW EXISTING CEILING. REF TYPICAL DETAILS. 3 NEW ACOUSTIC CEILING TILES TO MATCH APC-1 IN EXISTING GRID. REPAINT GRID WHITE, COLOR SELECTED BY ARCHITECT. 4 NOT USED 5 NEW CEILING GRID TO MATCH EXISTING ADJACENT CEILING. MATCH EXISTING CEILING HEIGHT AND TYPE. INTEGRATE NEW CEILING GRID INTO EXISTING GRID PATTERN. V.I.F. 6 BASE BID: EXISTING CEILINGS TO REMAIN; NEW GWB BULKHEAD 4" BELOW EXISTING ADJACENT CEILINGS. REF TYPICAL DETAILS. ROOM B137 ALTERNATE: NEW LAY-IN CEILING TO MATCH EXISTING ADJACENT CEILING HEIGHT AND CONFIGURATION. V.I.F. 7 ALIGN FACE OF BULKHEAD WITH FACE OF ADJACENT WALL 8 BULKHEAD TO RECEIVE PAINT, P-2, IN ITS ENTIRETY. 1A 1/8" = 1'-0" REFLECTED CEILING PLAN - UNIT A 3E 1 1/2" = 1'-0" TYPICAL BULKHEAD DETAIL # Revision Date B107 OFFICE B108 OFFICE B115A KITCHENETTE B122 VESTIBULE B111B CORRIDOR B001 PARENT ROOM B100 COPIER B109 CLASSROOM B136 CLASSROOM B118 CLASSROOM B119 STORAGE B146A WOMENS RR B148 MENS RR B149 RR B134 PLUMBING B123 IDF B129 STORAGE B139 STORAGE B140 STORAGE B142 STORAGE B143 STORAGE B144 STORAGE B129A STORAGE B129B OFFICE B147 OFFICE B119A OFFICE B124 KITCHEN B128 KITCHENETTE B133 STORAGE B146 F-4 03 F-3 F-3 01 S4-C S4iC S4iC S4iC 10 11 11 11 11 11 1' - 4" 6' - 0" 3' - 0" 6' - 0" F-4 10' - 6" CLR. S4iC 5' - 4" 5' - 4" 12" MIN. CLR. OFFICE B137A 01 01 S4iC S4iC B137 F ETR HM-112A Exist : HM-112D (9'-2")=F2 21 22 2' - 0" 2' - 0" ROOM B137 ALTERNATE A. Comply with all applicable codes and regulations pertaiting to this scope of work. B. All products to be handled, stored, and installed per manufacturer requirements. C. All dimensions shown are to face of stud or masonry, unless noted otherwise. Dimensions designated as "CLR or "clear" indicate a clear dimension from face of finish to face of finish. Dimensions of exterior walls are to outside edge of foundation. D. All openings for Mechanical, Plumbing, Fire Protection and Electrical shall be fire stopped at each floor penetration. E. Dimensional Lumber shall be Construction or No 2 Grade. Any concealed lumber in contact with concrete or masonry shall be preservative treated according to AWPA C2. F. Provide bracing and blocking as required in walls supporting casework, tackboards, markerboards, and restroom accessories. Blocking shall be solid wood minimum 3/4" x 6" wide. G. All door frames are located 4" from adjacent wall, unless noted otherwise. H. All exposed outside corners of CMU shall be bullnosed. I. Seal all joints between dissimilar materials with nonstaining sealant apropriate for both materials and application. J. All gypsum wallboard is 5/8" Type "X", unless noted otherwise. K. Where new floors meet existing floors, a smooth, straight, and flush transition shall be constructed. Verify in field existing floor elevations and conditions where a new floor shall be constructed adjacent. Trim and patch existing floor as required to achieve desired transition. L. All interior walls are Type "S4-C", unless noted otherwise. M. Refer to C Series drawings for base elevation height (0'-0") relative to USGS (United States Geological Survey data). N. Hatching within walls shown in plans and sections indicates new construction. M. Loose furniture is not provided in this contract. General Plan Notes N 6 5 4 3 2 1 A B C D E 6 5 4 3 2 1 A B C D E Project No. Project Date Produced These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect. KEY PLAN B A 5/22/2023 2:33:21 PM C:\_RevitLocal\2023-067.POR_Bldg001_A_2023\2023-067.POR_Bldg001_A_2023_mmiller.rvt 2023-067.POR 05.22.2023 FIRST FLOOR PLAN - UNIT B AF1B1 MW Coram Deo Academy Phase One Renovations 2023-067.POR_Coram Deo Academy_Phase One Renovations_ 525 Congressional Blvd, Carmel, IN 46032 AF1B1_ FIRST FLOOR PLAN - UNIT B 1A 1/8" = 1'-0" FLOOR PLAN - UNIT B FLOOR PLAN NOTES # Note 01 ALIGN FACE OF NEW WALL/INFILL WITH ADJACENT WALL FACE. 02 INFILL OPENING WITH WALL TO MATCH SURROUNDING/ADJACENT WALL CONSTRUCTION. VERIFY EXISTING WALL CONDITIONS/CONSTRUCTION AND DIMENSIONS IN THE FIELD. ALIGN THE FACE OF THE NEW INFILL WALL WITH THE ADJACENT EXISTING WALL FACE. 03 INTERIOR WOODFRAMED WINDOW WITH GLAZING. REF A-600 FOR SIZE AND DETAILS 04 RELOCATED EXISTING DOOR AND FRAME, REF A-600 SERIES FOR SIZE AND TYPE. 05 BASE BID: EXISTING FLOORING TO REMAIN; PATCH AREAS AFFECTED BY DEMOLITION WITH SALVAGED OR NEW TO MATCH EXISTING CARPET TILE. SCIENCE LAB ALTERNATE: SCIENCE LAB EQUIPMENT, CASEWORK AND RESILIENT SHEET FLOORING AS SHOWN. 06 NEW DOOR IN EXISTING FRAME WITH NEW CONTINUOUS ALUMINUM HINGE. REF DOOR SCHEDULE FOR SIZE. VERIFY IN FIELD. 07 REATTACH EXISTING RAILING TO EXISTING CONCRETE STAIR; REF DETAILS 08 GYMNASIUM WALL PADS, 2' L X 4' H. WRAP ALL OUTSIDE CORNERS AND EDGES TO CREATE A CONTINUOUS RUN. 09 RUBBER TILE USED FOR INFILL POST DEMOLITION ARE TO MATCH EXISTING. 10 FOLLOWING DEMOLITION, FLOORING ON GROUND IS TO BE VINYL COMPOSITION TILE, VCT. VCT IS TO ABUTT TO EXISTING VCT AND IS TO MATCH EXISTING. 11 AREAS AFFECTED BY DEMOLITION ARE TO RECEIVE CARPET TILE. CARPET TILES ARE TO MATCH EXISTING 12 EYEWASH STATION; REF P-SERIES DWGS. 13 BASE BID: GYMNASIUM WALL PADS BELOW SILL. GYMNASIUM WALL ALTERNATE: NEW WALL CONSTRUCTION IN FRONT OF EXISTING WINDOWS; REF SECTION DETAILS. 14 WRAP CORNER WITH GYMNASIUM WALL PADS; TERMINATE AT FACE OF EXISTING STOREFRONT. 15 NEW UTILITY SINK- REF P-DWGS 16 BASE BID: EXISTING DOOR AND FRAME TO REMAIN. MUSIC DOOR ALTERNATE: RELOCATED DOOR AND NEW WALL CONSTRUCTION AS SHOWN. REF DOOR SCHEDULE FOR SIZE AND TYPE 17 BASE BID: EXISTING DOOR TO REMAIN. SCIENCE LAB ALTERNATE: REMOVE EXISTING DOOR AND APPLY PLAN NOTE 2. 18 FOLLOWING DEMOLITION, FLOORING ON GROUND IS TO BE CARPET TILE, CPT-1 (MATCH EXISTING). EXISTING VCT IS TO BE DEMOLISHED OR COVERED WITH CPT-1. 19 EXISTING FLOORING FINISH ON RISERS AND FABRIC-WRAPPED WALL PANELS ARE TO BE EXISTING TO REMAIN. 20 WALL TO RECEIVE PAINT, P-2, INSIDE CORNER TO INSIDE CORNER. 21 BASE BID: 4 OFFICES COMBINED INTO 1 SPACE, REF DEMOLITION PLANS. ROOM B137 ALTERNATE: NEW WALL CONSTRUCTION AS SHOWN. 22 RELOCATED FIRE PANEL. COORDINATE FINAL LOCATION WITH OWNER IN FIELD. 23 SCIENCE LAB ALTERNATE: NEW DRYWALL ON EXISTING STUD TO DECK, BOTH SIDES OF THE WALL. REF WALL SECTIONS AND DETAILS. 24 PATCH AND REPAIR EXISTING GWB TO CREATE A SEAMLESS, SMOOTH TRANSITION. PREP FOR FINISH 25 NEW FLOORING (LVT) TO ALIGN WITH NEW BULKHEADS. 26 MECHANICAL HOOD. BASIS OF DESIGN ELIMINATOR 500 SERIES ADA DESIGN. PART # EH-511-72.INCLUDE (1) CORROSIVE AND (1) FLAMMABLE BASE CABINET BELOW. REF M-SERIES DWGS 27 NEW DOOR CLOSER ON EXISTING DOOR. BASIS OF DESIGN LCN 1250 SERIES. 28 NEW STAINLESS STEEL KICK PLATE MOUNED TO FACE OF ALUMINUM EXTERIOR DOOR. EXTEND MIN 1" BEYOND EDGE OF GLASS IN DOOR AND TO BOTTOM OF EXIT DEVICE. ATTACH WITH COMPATIBLE METAL SCREWS INSTALLED IN FOAM GASKET; COUNTERINK ALL HOLES IN EXISTING DOOR. SEPARATE DISSIMILAR METALS WITH NON CORROSIVE MATERIALS. FIELD VERIFY. # Revision Date SHADED REGIONS ARE NO SCOPE ROOMS; ALL EXISTING TO REMAIN. CLASSROOM B120 CLASSROOM B110 CLASSROOM A113 STORAGE B112 STORAGE A112 STORAGE A111 STORAGE A117 BREAK ROOM A106 PRACTICE ROOM B117A PRACTICE ROOM B116 PRACTICE ROOM B114 PRACTICE ROOM B113 WOMENS RR B104 WOMENS RR A108 MENS RR A109 MENS RR B103 ELECTRICAL A112A UNOCCUPIED A130 UNOCCUPIED A129 UNOCCUPIED A128 UNOCCUPIED A127 UNOCCUPIED A126 UNOCCUPIED A125 UNOCCUPIED A124 UNOCCUPIED A123 UNOCCUPIED A122 STORAGE A106A STORAGE B102 STORAGE A103A JANITOR A107 RISER RM A108A OFFICE A102 OFFICE A103 OFFICE A104 OFFICE B105 OFFICE B106 OFFICE B107 OFFICE B108 OFFICE B115A STORAGE B115B STORAGE B115C OFFICE A105 VESTIBULE A110B VESTIBULE A100A CORRIDOR A003 CORRIDOR A001 VESTIBULE A003A CLINIC A101 PARENT ROOM B100 COPIER B109 LOBBY A100 VESTIBULE A003B STORAGE B101 OFFICE A115 OFFICE A114 PRACTICE ROOM B114 LOBBY A100 09 11 11 12 13 14 14 15 11 EQ. EQ. 06 A110.4 F ETR HM1 : HM-001 2=F1 17 12" MIN CLR. MB10 I-201 2E 2C I-201 2A 2D 2B 23 1A A-600 NRIU 24 16 SCIENCE LAB ALT. 05 13 13 ALT. 26 27 28 24 5C 5B I-201 5A A. Comply with all applicable codes and regulations pertaiting to this scope of work. B. All products to be handled, stored, and installed per manufacturer requirements. C. All dimensions shown are to face of stud or masonry, unless noted otherwise. Dimensions designated as "CLR or "clear" indicate a clear dimension from face of finish to face of finish. Dimensions of exterior walls are to outside edge of foundation. D. All openings for Mechanical, Plumbing, Fire Protection and Electrical shall be fire stopped at each floor penetration. E. Dimensional Lumber shall be Construction or No 2 Grade. Any concealed lumber in contact with concrete or masonry shall be preservative treated according to AWPA C2. F. Provide bracing and blocking as required in walls supporting casework, tackboards, markerboards, and restroom accessories. Blocking shall be solid wood minimum 3/4" x 6" wide. G. All door frames are located 4" from adjacent wall, unless noted otherwise. H. All exposed outside corners of CMU shall be bullnosed. I. Seal all joints between dissimilar materials with nonstaining sealant apropriate for both materials and application. J. All gypsum wallboard is 5/8" Type "X", unless noted otherwise. K. Where new floors meet existing floors, a smooth, straight, and flush transition shall be constructed. Verify in field existing floor elevations and conditions where a new floor shall be constructed adjacent. Trim and patch existing floor as required to achieve desired transition. L. All interior walls are Type "S4-C", unless noted otherwise. M. Refer to C Series drawings for base elevation height (0'-0") relative to USGS (United States Geological Survey data). N. Hatching within walls shown in plans and sections indicates new construction. M. Loose furniture is not provided in this contract. General Plan Notes Level 1 0' - 0" Level 1 0' - 0" Level 1 0' - 0" Level 1 0' - 0" E AF1A1 4D 4' - 0" 05 40 00 - EXT. STEEL STUD FRAMING, 16 GA, @ 16" O.C. REINFORCED WITH MIDWALL 600MW-48 EVERY OTHER STUD 5/8 PLYWOOD SHEATHING EXISTING ALUMINUM STOREFRONT SYSTEM. PROTECT DURING CONSTRUCTION 2IN THICK GYMNASIUM WALL PADS SECURED TO WALL WITH Z CLIP ATTACHMENT SYSTEM. BASIS OF DESIGN "ECOVISION WALL PAD" BY DRAPER INC. 06 10 53.B2 - WOOD BLOCKING, 2X CONTINUOUS 1/2" PLYWOOD ATTACHED TO METAL STUDS. PAINT BLACK, COLOR SELECTED BY ARCHITECT. CLR. 2" MIN. 05 40 00.C23 - EXT. STEEL STUD FRAMING, 16-GAGE, 6" @ 16" O.C. WRAP TOP EDGE WITH GYMNASIUM WALL PADDING N 6 5 4 3 2 1 A B C D E 6 5 4 3 2 1 A B C D E Project No. Project Date Produced These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect. KEY PLAN B A 5/22/2023 2:33:04 PM C:\_RevitLocal\2023-067.POR_Bldg001_A_2023\2023-067.POR_Bldg001_A_2023_mmiller.rvt 2023-067.POR 05.22.2023 FIRST FLOOR PLAN - UNIT A AF1A1 MW Coram Deo Academy Phase One Renovations 2023-067.POR_Coram Deo Academy_Phase One Renovations_ 525 Congressional Blvd, Carmel, IN 46032 AF1A1_ FIRST FLOOR PLAN - UNIT A 1A 1/8" = 1'-0" FLOOR PLAN - UNIT A FLOOR PLAN NOTES # Note 01 ALIGN FACE OF NEW WALL/INFILL WITH ADJACENT WALL FACE. 02 INFILL OPENING WITH WALL TO MATCH SURROUNDING/ADJACENT WALL CONSTRUCTION. VERIFY EXISTING WALL CONDITIONS/CONSTRUCTION AND DIMENSIONS IN THE FIELD. ALIGN THE FACE OF THE NEW INFILL WALL WITH THE ADJACENT EXISTING WALL FACE. 03 INTERIOR WOODFRAMED WINDOW WITH GLAZING. REF A-600 FOR SIZE AND DETAILS 04 RELOCATED EXISTING DOOR AND FRAME, REF A-600 SERIES FOR SIZE AND TYPE. 05 BASE BID: EXISTING FLOORING TO REMAIN; PATCH AREAS AFFECTED BY DEMOLITION WITH SALVAGED OR NEW TO MATCH EXISTING CARPET TILE. SCIENCE LAB ALTERNATE: SCIENCE LAB EQUIPMENT, CASEWORK AND RESILIENT SHEET FLOORING AS SHOWN. 06 NEW DOOR IN EXISTING FRAME WITH NEW CONTINUOUS ALUMINUM HINGE. REF DOOR SCHEDULE FOR SIZE. VERIFY IN FIELD. 07 REATTACH EXISTING RAILING TO EXISTING CONCRETE STAIR; REF DETAILS 08 GYMNASIUM WALL PADS, 2' L X 4' H. WRAP ALL OUTSIDE CORNERS AND EDGES TO CREATE A CONTINUOUS RUN. 09 RUBBER TILE USED FOR INFILL POST DEMOLITION ARE TO MATCH EXISTING. 10 FOLLOWING DEMOLITION, FLOORING ON GROUND IS TO BE VINYL COMPOSITION TILE, VCT. VCT IS TO ABUTT TO EXISTING VCT AND IS TO MATCH EXISTING. 11 AREAS AFFECTED BY DEMOLITION ARE TO RECEIVE CARPET TILE. CARPET TILES ARE TO MATCH EXISTING 12 EYEWASH STATION; REF P-SERIES DWGS. 5D 3/4" = 1'-0" ALTERNATE - WALL SECTION @ GYM WINDOWS 4D 1 1/2" = 1'-0" SECTION DETAIL - WALL CAP FLOOR PLAN NOTES # Note 13 BASE BID: GYMNASIUM WALL PADS BELOW SILL. GYMNASIUM WALL ALTERNATE: NEW WALL CONSTRUCTION IN FRONT OF EXISTING WINDOWS; REF SECTION DETAILS. 14 WRAP CORNER WITH GYMNASIUM WALL PADS; TERMINATE AT FACE OF EXISTING STOREFRONT. 15 NEW UTILITY SINK- REF P-DWGS 16 BASE BID: EXISTING DOOR AND FRAME TO REMAIN. MUSIC DOOR ALTERNATE: RELOCATED DOOR AND NEW WALL CONSTRUCTION AS SHOWN. REF DOOR SCHEDULE FOR SIZE AND TYPE 17 BASE BID: EXISTING DOOR TO REMAIN. SCIENCE LAB ALTERNATE: REMOVE EXISTING DOOR AND APPLY PLAN NOTE 2. 18 FOLLOWING DEMOLITION, FLOORING ON GROUND IS TO BE CARPET TILE, CPT-1 (MATCH EXISTING). EXISTING VCT IS TO BE DEMOLISHED OR COVERED WITH CPT-1. 19 EXISTING FLOORING FINISH ON RISERS AND FABRIC-WRAPPED WALL PANELS ARE TO BE EXISTING TO REMAIN. 20 WALL TO RECEIVE PAINT, P-2, INSIDE CORNER TO INSIDE CORNER. 21 BASE BID: 4 OFFICES COMBINED INTO 1 SPACE, REF DEMOLITION PLANS. ROOM B137 ALTERNATE: NEW WALL CONSTRUCTION AS SHOWN. 22 RELOCATED FIRE PANEL. COORDINATE FINAL LOCATION WITH OWNER IN FIELD. 23 SCIENCE LAB ALTERNATE: NEW DRYWALL ON EXISTING STUD TO DECK, BOTH SIDES OF THE WALL. REF WALL SECTIONS AND DETAILS. 24 PATCH AND REPAIR EXISTING GWB TO CREATE A SEAMLESS, SMOOTH TRANSITION. PREP FOR FINISH 25 NEW FLOORING (LVT) TO ALIGN WITH NEW BULKHEADS. 26 MECHANICAL HOOD. BASIS OF DESIGN ELIMINATOR 500 SERIES ADA DESIGN. PART # EH-511-72.INCLUDE (1) CORROSIVE AND (1) FLAMMABLE BASE CABINET BELOW. REF M-SERIES DWGS 27 NEW DOOR CLOSER ON EXISTING DOOR. BASIS OF DESIGN LCN 1250 SERIES. 28 NEW STAINLESS STEEL KICK PLATE MOUNED TO FACE OF ALUMINUM EXTERIOR DOOR. EXTEND MIN 1" BEYOND EDGE OF GLASS IN DOOR AND TO BOTTOM OF EXIT DEVICE. ATTACH WITH COMPATIBLE METAL SCREWS INSTALLED IN FOAM GASKET; COUNTERINK ALL HOLES IN EXISTING DOOR. SEPARATE DISSIMILAR METALS WITH NON CORROSIVE MATERIALS. FIELD VERIFY. # Revision Date SHADED REGIONS ARE NO SCOPE ROOMS; ALL EXISTING TO REMAIN. SCIENCE LAB A121 BREAK ROOM A106 GYM A110 STORAGE A110A RR A110C ROOM B137 ALTERNATE SCIENCE LAB ALTERNATE GYMNASIUM WALL ALTERNATE MUSIC DOOR ALTERNATE N 6 5 4 3 2 1 A B C D E 6 5 4 3 2 1 A B C D E Project No. Project Date Produced These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect. KEY PLAN B A 5/22/2023 2:32:32 PM C:\_RevitLocal\2023-067.POR_Bldg001_A_2023\2023-067.POR_Bldg001_A_2023_mmiller.rvt 2023-067.POR 05.22.2023 OVERALL FIRST FLOOR PLAN AF101 MW Coram Deo Academy Phase One Renovations 2023-067.POR_Coram Deo Academy_Phase One Renovations_ 525 Congressional Blvd, Carmel, IN 46032 AF101_ OVERALL FIRST FLOOR PLAN 1B 1/16" = 1'-0" OVERALL FLOOR PLAN # Revision Date 22 22 22 22 22 22 22 22 22 22 22 07 08 08 08 08 08 08 08 08 08 08 08 08 08 08 08 08 08 07 01 01 04 05 01 09 08 08 09 09 09 09 09 09 09 09 09 09 09 09 09 09 09 09 11 12 13 01 01 09 03 03 03 03 21 03 03 16 03 03 03 03 03 03 03 03 03 17 05 01 ALT. 05 01 ALT. 05 01 ALT. 17 03 04 ALT. 04 ALT. 04 04 04 18 19 01 20 22 22 22 02 09 08 08 08 03 ROOM B137 ALTERNATE 04 ALT. 04 ALT. 04 04 04 04 04 04 04 04 04 04 04 04 A. Contractor shall field-verify all existing conditions, dimensions, and arrangements. B. Contractor is responsible for protection of all existing surfaces, materials, and components to remain or be relocated. Damage to these resulting from performance of Work shall be repaired by Contractor to satisfaction of Owner and Architect at no additional expense to Owner. C. Contractor shall provide temporary dust protection as required to prevent construction debris and dust from migrating out of Project Area. Owner/Architect shall confirm all dust prevention measures/locations and shall determine changes to these measures. D. All existing equipment and fixtures shall remain property of Owner. All reusable items salvaged during demolition operations shall be retained for Owner's inspection. Only items so inspected and rejected by Owner shall be disposed. All other such items shall be turned over to Owner for disposition. E. All existing surfaces located adjacent to, or exposed by demolition work and scheduled to receive new construction shall be patched and repaired as required to cleanly receive new work. F. All existing surfaces located adjacent to, or exposed by demolition work and scheduled to remain exposed after completion of new const. shall be repaired and patched as required to receive new finishes. G. Owner will be responsible for removal/rearrangement of all existing loose furnishings during construction, unless noted otherwise. H. Refer to Mech./Elec. Drawings for additional patching and preparation work related to M.E.P. demolition items. I. Existing sleeves, holes, and other penetrations or new damage of existing building structure above grade exposed by demolition and removal of piping, appurtenances, equipment shall be patched and repaired as part of the Work. Maintain fire ratings of all and adjacent construction affected. J. Cap all piping to remain or abandoned in accordance with requirements of authority having jurisdiction and in accordance with all local and state plumbing and health codes. Utilize only pre-manufactured and approved fittings to cap existing piping. K. Each Contractor is responsible for all demolition work required or noted for installation of new Work. Demolition may include associated distribution systems, appurtenances, equipment supporting controls, and miscellaneous supports, unless noted otherwise. L. Coordinate all demolition with Project sequencing as directed by General Contractor or Construction Manager. General Demolition Notes N 6 5 4 3 2 1 A B C D E 6 5 4 3 2 1 A B C D E Project No. Project Date Produced These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect. KEY PLAN B A 5/22/2023 2:32:08 PM C:\_RevitLocal\2023-067.POR_Bldg001_A_2023\2023-067.POR_Bldg001_A_2023_mmiller.rvt 2023-067.POR 05.22.2023 DEMOLITION FLOOR PLAN - UNIT B AD1B1 MW Coram Deo Academy Phase One Renovations 2023-067.POR_Coram Deo Academy_Phase One Renovations_ 525 Congressional Blvd, Carmel, IN 46032 AD1B1_ DEMOLITION FLOOR PLAN - UNIT B 1/8" = 1'-0" 1A DEMOLITION FLOOR PLAN - UNIT B DEMOLITION FLOOR PLAN NOTES # NOTE 01 REMOVE EXISTING INTERIOR WALL CONSTRUCTION IN ITS ENTIRETY TO LIMITS INDICATED INCLUDING, BUT NOT LIMITED TO DOORS, FRAMES, WINDOWS AND ALL MISCELLANEOUS FRAMING. FIELD VERIFY ALL EXISTING WALL CONSTRUCTION PRIOR TO DEMOLITION. REFER TO ARCHITECTURAL AND INTERIOR FLOOR PLANS FOR FINISH CONDITIONS AND DIMENSIONS. PATCH AND REPAIR EXISTING ADJACENT SURFACES TO REMAIN AND PREP FOR NEW CONSTRUCITON. 02 BASE BID: EXISTING CARPET TILE TO REMAIN. SCIENCE LAB ALTERNATE: REMOVE EXISTING CARPET FLOOR FINISH IN ITS ENTIRETY TO LIMITS INDICATED INCLUDING, BUT NOT LIMITED TO THE CARPET, ADHESIVES/TACK STRIPS, TRANSITION STRIPS AND ALL ASSOCIATED WALL BASE. SALVAGE CARPET TILES FOR PATCHING FLOORING IN OTHER LOCATIONS. PATCH AND REPAIR EXISTING SURFACES TO REMAIN AND PREP FOR NEW CONSTRUCTION/FINISH. 02 REMOVE EXISTING CARPET FLOOR FINISH IN ITS ENTIRETY TO LIMITS INDICATED INCLUDING, BUT NOT LIMITED TO THE CARPET, ADHESIVES/TACK STRIPS, TRANSITION STRIPS AND ALL ASSOCIATED WALL BASE. SALVAGE CARPET TILES FOR PATCHING FLOORING IN OTHER LOCATIONS. PATCH AND REPAIR EXISTING SURFACES TO REMAIN AND PREP FOR NEW CONSTRUCTION/FINISH. 03 EXISTING SUSPENDED ACOUSTICAL CEILING SYSTEM TO REMAIN. PROTECT CEILING SYSTEM AND MODIFY CEILING SYSTEM AS REQUIRED FOR NEW CONSTRUCTION. 04 REMOVE EXISTING SUSPENDED LAY-IN PANEL CEILING SYSTEM IN ITS ENTIRETY INCLUDING, BUT NOT LIMITED TO THE CEILING PADS, GRID, SUSPENSION WIRES, AND ALL RELATED ANCHORS. PATCH AND REPAIR EXISTING SURFACES TO REMAIN AND PREP FOR NEW CONSTRUCTION/FINISH. 05 REMOVE EXISTING DOOR SYSTEM IN ITS ENTIRETY INCLUDING, BUT NOT LIMITED TO THE DOOR, FRAME, SIDELIGHTS, GLAZING, HARDWARE AND ALL RELATED ANCHORS. SALVAGE FOR RELOCATION; REF A-SERIES DWGS FOR NEW LOCATION. PREP EXISTING OPENING FOR NEW CONSTRUCTION. PATCH AND REPAIR ALL ADJACENT SURFACES TO REMAIN FOR NEW CONSTRUCTION/FINISH. 06 REMOVE EXISTING DOOR AND ALL RELATED HARDWARE. PROTECT EXISTING DOOR FRAME TO REMAIN. PREP EXISTING DOOR FRAME FOR NEW CONSTRUCTION. 07 REMOVE EXISTING WINDOW SYSTEM IN ITS ENTIRETY INCLUDING, BUT NOT LIMITED TO THE GLAZING, SPANDREL PANELS, WINDOW FRAME, SEALANTS, AND ALL RELATED ANCHORS. PATCH AND REPAIR ADJACENT SURFACES TO REMAIN AND PREP FOR NEW CONSTRUCTION/FINISH. DEMOLITION FLOOR PLAN NOTES # NOTE 08 REMOVE EXISTING CASEWORK IN ITS ENTIRETY INCLUDING, BUT NOT LIMITED TO WALL CABINETS, BASE CABINETS, AND ASSOCIATED COUNTERTOP. SALVAGE AND PLACE IN OWNER DESIGNATED STORAGE AREA. PATCH AND REPAIR EXISTING ADJACENT SURFACES TO REMAIN AND PREP FOR NEW CONSTRUCTION. 09 REMOVE EXISTING CASEWORK IN ITS ENTIRETY INCLUDING, BUT NOT LIMITED TO BASE CABINETS, COUNTERTOPS, FILL PANELS, AND ALL RELATED ANCHORS. PATCH AND REPAIR EXISTING ADJACENT SURFACES TO REMAIN AND PREP FOR NEW CONSTRUCTION. 10 EXISTING LAMINATE FLOORING TO REMAIN, PROTECT DURING CONSTRUCTION 11 REMOVE EXISTING INTERIOR WALL CONSTRUCTION IN ITS ENTIRETY BELOW WINDOW FRAME. FIELD VERIFY ALL EXISTING WALL CONSTRUCTION PRIOR TO DEMOLITION. 12 REMOVE EXISTING LIBRARY SHELVING IN ITS ENTIRELY AND SALVAGE FOR REUSE AND RELOCATION. 13 REMOVE EXISTING CARPET FLOOR FINISH IN ITS ENTIRETY TO LIMITS INDICATED INCLUDING, BUT NOT LIMITED TO THE CARPET, ADHESIVES/TACK STRIPS, TRANSITION STRIPS AND ALL ASSOCIATED WALL BASE. CARPET ONLY ON GROUND LEVEL IS TO BE DEMOLISHED. EXISTING CARPET ON RISERS SHALL BE EXISTING TO REMAIN. 15 REMOVE INTERIOR WALL AS REQUIRED FOR PLUMBING WORK. PATCH AND REPAIR EXISTING SURFACES TO REMAIN. CREATE A SMOOTH AND SEAMLESS TRANSITION. MATCH EXISTING FINISH TYPE AND COLOR, V.I.F. 16 BASE BID: APPLY DEMOLITION NOTES 01, 03, 08, 09 SIMILAR TO ADJACENT OFFICES. ROOM B137 ALTERNATE: EXISTING CONSTRUCTION TO REMAIN. 17 BASE BID: EXISTING WALLS AND FRAMES TO REMAIN. ROOM B137 ALTERNATE: APPLY DEMOLITION NOTES AS SHOWN. 18 REMOVE EXISTING FIRE PANEL INCLUDING BUT NOT LIMITED TO ALL RELATED ANCHORS, COVERS, AND CONDUIT. SALVAGE FOR RELOCATION. REF FLOOR PLANS FOR NEW PANEL LOCATION. 19 REMOVE EXISTING WALLCOVERING IN ITS ENTIRETY INCLUDING ADHESIVES. PATCH AND REPAIR ALL EXISTING SURFACES TO REMAIN. PREP EXISTING SURFACES FOR NEW CONSTRUCTION/FINISH. 20 REMOVE EXISTING PROJECTOR BOX INCLUDING BUT NOT LIMITED TO ALL HANGERS, ATTACHMENTS, AND ACCESSORIES. PREP REMAINING SURFACES FOR NEW CONSTRUCTION. 21 EXISTING CEILING GRID TO REMAIN. REPLACE TILES WITH ACP-1 22 REMOVE EXISTING INTERIOR WALL CONSTRUCTION IN ITS ENTIRETY TO LIMITS INDICATED INCLUDING, BUT NOT LIMITED TO DOORS, FRAMES, WINDOWS AND ALL MISCELLANEOUS FRAMING. FIELD VERIFY ALL EXISTING WALL CONSTRUCTION PRIOR TO DEMOLITION. REFER TO ARCHITECTURAL AND INTERIOR FLOOR PLANS FOR FINISH CONDITIONS AND DIMENSIONS. PATCH AND REPAIR EXISTING ADJACENT SURFACES TO REMAIN AND PREP FOR NEW CONSTRUCITON. SALVAGE OAK WALL CAPS AND PLACE IN OWNER DESIGNATED STORAGE AREA. 24 REMOVE DAMAGED GWB FROM WALL INCLUDING BUT NOT LIMITED TO ANY RELATED FASTENERS, ADHESIVES, ETC. PREP REMAINING SURFACES FOR NEW CONSTRUCTION. VERIFY EXTENT AND LOCATIONS IN FIELD 25 REMOVE EXISTING TOILETS, SINKS, URINALS AND ALL RELATED ACCESSORIES IN THEIR ENTIRETY INCLUDING, BUT NOT LIMITED TO TOILET PAPER DISPENSERS, GRAB BARS, MIRRORS AND SOAP DISPENSERS. PATCH AND REPAIR ALL EXISTING SURFACES TO REMAIN. PREP FOR NEW CONSTRUCTION/FINISH. SEE P-SERIES DRAWINGS FOR PLUMBING SCOPE. # Revision Date 08 08 09 08 01 01 09 09 09 09 01 01 01 08 08 08 08 08 08 08 08 08 08 03 03 03 03 03 03 03 03 03 03 02 02 02 02 02 15 24 05 MUSIC DOOR ALT. SCIENCE LAB ALT. 04 04 04 04 04 04 25 04 04 04 04 04 04 04 04 04 04 A. Contractor shall field-verify all existing conditions, dimensions, and arrangements. B. Contractor is responsible for protection of all existing surfaces, materials, and components to remain or be relocated. Damage to these resulting from performance of Work shall be repaired by Contractor to satisfaction of Owner and Architect at no additional expense to Owner. C. Contractor shall provide temporary dust protection as required to prevent construction debris and dust from migrating out of Project Area. Owner/Architect shall confirm all dust prevention measures/locations and shall determine changes to these measures. D. All existing equipment and fixtures shall remain property of Owner. All reusable items salvaged during demolition operations shall be retained for Owner's inspection. Only items so inspected and rejected by Owner shall be disposed. All other such items shall be turned over to Owner for disposition. E. All existing surfaces located adjacent to, or exposed by demolition work and scheduled to receive new construction shall be patched and repaired as required to cleanly receive new work. F. All existing surfaces located adjacent to, or exposed by demolition work and scheduled to remain exposed after completion of new const. shall be repaired and patched as required to receive new finishes. G. Owner will be responsible for removal/rearrangement of all existing loose furnishings during construction, unless noted otherwise. H. Refer to Mech./Elec. Drawings for additional patching and preparation work related to M.E.P. demolition items. I. Existing sleeves, holes, and other penetrations or new damage of existing building structure above grade exposed by demolition and removal of piping, appurtenances, equipment shall be patched and repaired as part of the Work. Maintain fire ratings of all and adjacent construction affected. J. Cap all piping to remain or abandoned in accordance with requirements of authority having jurisdiction and in accordance with all local and state plumbing and health codes. Utilize only pre-manufactured and approved fittings to cap existing piping. K. Each Contractor is responsible for all demolition work required or noted for installation of new Work. Demolition may include associated distribution systems, appurtenances, equipment supporting controls, and miscellaneous supports, unless noted otherwise. L. Coordinate all demolition with Project sequencing as directed by General Contractor or Construction Manager. General Demolition Notes N 6 5 4 3 2 1 A B C D E 6 5 4 3 2 1 A B C D E Project No. Project Date Produced These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect. KEY PLAN B A 5/22/2023 2:31:53 PM C:\_RevitLocal\2023-067.POR_Bldg001_A_2023\2023-067.POR_Bldg001_A_2023_mmiller.rvt 2023-067.POR 05.22.2023 DEMOLITION FLOOR PLAN - UNIT A AD1A1 MW Coram Deo Academy Phase One Renovations 2023-067.POR_Coram Deo Academy_Phase One Renovations_ 525 Congressional Blvd, Carmel, IN 46032 AD1A1_ DEMOLITION FLOOR PLAN - UNIT A 1/8" = 1'-0" 1A DEMOLITION FLOOR PLAN - UNIT A DEMOLITION FLOOR PLAN NOTES # NOTE 01 REMOVE EXISTING INTERIOR WALL CONSTRUCTION IN ITS ENTIRETY TO LIMITS INDICATED INCLUDING, BUT NOT LIMITED TO DOORS, FRAMES, WINDOWS AND ALL MISCELLANEOUS FRAMING. FIELD VERIFY ALL EXISTING WALL CONSTRUCTION PRIOR TO DEMOLITION. REFER TO ARCHITECTURAL AND INTERIOR FLOOR PLANS FOR FINISH CONDITIONS AND DIMENSIONS. PATCH AND REPAIR EXISTING ADJACENT SURFACES TO REMAIN AND PREP FOR NEW CONSTRUCITON. 02 BASE BID: EXISTING CARPET TILE TO REMAIN. SCIENCE LAB ALTERNATE: REMOVE EXISTING CARPET FLOOR FINISH IN ITS ENTIRETY TO LIMITS INDICATED INCLUDING, BUT NOT LIMITED TO THE CARPET, ADHESIVES/TACK STRIPS, TRANSITION STRIPS AND ALL ASSOCIATED WALL BASE. SALVAGE CARPET TILES FOR PATCHING FLOORING IN OTHER LOCATIONS. PATCH AND REPAIR EXISTING SURFACES TO REMAIN AND PREP FOR NEW CONSTRUCTION/FINISH. 02 REMOVE EXISTING CARPET FLOOR FINISH IN ITS ENTIRETY TO LIMITS INDICATED INCLUDING, BUT NOT LIMITED TO THE CARPET, ADHESIVES/TACK STRIPS, TRANSITION STRIPS AND ALL ASSOCIATED WALL BASE. SALVAGE CARPET TILES FOR PATCHING FLOORING IN OTHER LOCATIONS. PATCH AND REPAIR EXISTING SURFACES TO REMAIN AND PREP FOR NEW CONSTRUCTION/FINISH. 03 EXISTING SUSPENDED ACOUSTICAL CEILING SYSTEM TO REMAIN. PROTECT CEILING SYSTEM AND MODIFY CEILING SYSTEM AS REQUIRED FOR NEW CONSTRUCTION. 04 REMOVE EXISTING SUSPENDED LAY-IN PANEL CEILING SYSTEM IN ITS ENTIRETY INCLUDING, BUT NOT LIMITED TO THE CEILING PADS, GRID, SUSPENSION WIRES, AND ALL RELATED ANCHORS. PATCH AND REPAIR EXISTING SURFACES TO REMAIN AND PREP FOR NEW CONSTRUCTION/FINISH. 05 REMOVE EXISTING DOOR SYSTEM IN ITS ENTIRETY INCLUDING, BUT NOT LIMITED TO THE DOOR, FRAME, SIDELIGHTS, GLAZING, HARDWARE AND ALL RELATED ANCHORS. SALVAGE FOR RELOCATION; REF A-SERIES DWGS FOR NEW LOCATION. PREP EXISTING OPENING FOR NEW CONSTRUCTION. PATCH AND REPAIR ALL ADJACENT SURFACES TO REMAIN FOR NEW CONSTRUCTION/FINISH. 06 REMOVE EXISTING DOOR AND ALL RELATED HARDWARE. PROTECT EXISTING DOOR FRAME TO REMAIN. PREP EXISTING DOOR FRAME FOR NEW CONSTRUCTION. 07 REMOVE EXISTING WINDOW SYSTEM IN ITS ENTIRETY INCLUDING, BUT NOT LIMITED TO THE GLAZING, SPANDREL PANELS, WINDOW FRAME, SEALANTS, AND ALL RELATED ANCHORS. PATCH AND REPAIR ADJACENT SURFACES TO REMAIN AND PREP FOR NEW CONSTRUCTION/FINISH. DEMOLITION FLOOR PLAN NOTES # NOTE 08 REMOVE EXISTING CASEWORK IN ITS ENTIRETY INCLUDING, BUT NOT LIMITED TO WALL CABINETS, BASE CABINETS, AND ASSOCIATED COUNTERTOP. SALVAGE AND PLACE IN OWNER DESIGNATED STORAGE AREA. PATCH AND REPAIR EXISTING ADJACENT SURFACES TO REMAIN AND PREP FOR NEW CONSTRUCTION. 09 REMOVE EXISTING CASEWORK IN ITS ENTIRETY INCLUDING, BUT NOT LIMITED TO BASE CABINETS, COUNTERTOPS, FILL PANELS, AND ALL RELATED ANCHORS. PATCH AND REPAIR EXISTING ADJACENT SURFACES TO REMAIN AND PREP FOR NEW CONSTRUCTION. 10 EXISTING LAMINATE FLOORING TO REMAIN, PROTECT DURING CONSTRUCTION 11 REMOVE EXISTING INTERIOR WALL CONSTRUCTION IN ITS ENTIRETY BELOW WINDOW FRAME. FIELD VERIFY ALL EXISTING WALL CONSTRUCTION PRIOR TO DEMOLITION. 12 REMOVE EXISTING LIBRARY SHELVING IN ITS ENTIRELY AND SALVAGE FOR REUSE AND RELOCATION. 13 REMOVE EXISTING CARPET FLOOR FINISH IN ITS ENTIRETY TO LIMITS INDICATED INCLUDING, BUT NOT LIMITED TO THE CARPET, ADHESIVES/TACK STRIPS, TRANSITION STRIPS AND ALL ASSOCIATED WALL BASE. CARPET ONLY ON GROUND LEVEL IS TO BE DEMOLISHED. EXISTING CARPET ON RISERS SHALL BE EXISTING TO REMAIN. 15 REMOVE INTERIOR WALL AS REQUIRED FOR PLUMBING WORK. PATCH AND REPAIR EXISTING SURFACES TO REMAIN. CREATE A SMOOTH AND SEAMLESS TRANSITION. MATCH EXISTING FINISH TYPE AND COLOR, V.I.F. 16 BASE BID: APPLY DEMOLITION NOTES 01, 03, 08, 09 SIMILAR TO ADJACENT OFFICES. ROOM B137 ALTERNATE: EXISTING CONSTRUCTION TO REMAIN. 17 BASE BID: EXISTING WALLS AND FRAMES TO REMAIN. ROOM B137 ALTERNATE: APPLY DEMOLITION NOTES AS SHOWN. 18 REMOVE EXISTING FIRE PANEL INCLUDING BUT NOT LIMITED TO ALL RELATED ANCHORS, COVERS, AND CONDUIT. SALVAGE FOR RELOCATION. REF FLOOR PLANS FOR NEW PANEL LOCATION. 19 REMOVE EXISTING WALLCOVERING IN ITS ENTIRETY INCLUDING ADHESIVES. PATCH AND REPAIR ALL EXISTING SURFACES TO REMAIN. PREP EXISTING SURFACES FOR NEW CONSTRUCTION/FINISH. 20 REMOVE EXISTING PROJECTOR BOX INCLUDING BUT NOT LIMITED TO ALL HANGERS, ATTACHMENTS, AND ACCESSORIES. PREP REMAINING SURFACES FOR NEW CONSTRUCTION. 21 EXISTING CEILING GRID TO REMAIN. REPLACE TILES WITH ACP-1 22 REMOVE EXISTING INTERIOR WALL CONSTRUCTION IN ITS ENTIRETY TO LIMITS INDICATED INCLUDING, BUT NOT LIMITED TO DOORS, FRAMES, WINDOWS AND ALL MISCELLANEOUS FRAMING. FIELD VERIFY ALL EXISTING WALL CONSTRUCTION PRIOR TO DEMOLITION. REFER TO ARCHITECTURAL AND INTERIOR FLOOR PLANS FOR FINISH CONDITIONS AND DIMENSIONS. PATCH AND REPAIR EXISTING ADJACENT SURFACES TO REMAIN AND PREP FOR NEW CONSTRUCITON. SALVAGE OAK WALL CAPS AND PLACE IN OWNER DESIGNATED STORAGE AREA. 24 REMOVE DAMAGED GWB FROM WALL INCLUDING BUT NOT LIMITED TO ANY RELATED FASTENERS, ADHESIVES, ETC. PREP REMAINING SURFACES FOR NEW CONSTRUCTION. VERIFY EXTENT AND LOCATIONS IN FIELD 25 REMOVE EXISTING TOILETS, SINKS, URINALS AND ALL RELATED ACCESSORIES IN THEIR ENTIRETY INCLUDING, BUT NOT LIMITED TO TOILET PAPER DISPENSERS, GRAB BARS, MIRRORS AND SOAP DISPENSERS. PATCH AND REPAIR ALL EXISTING SURFACES TO REMAIN. PREP FOR NEW CONSTRUCTION/FINISH. SEE P-SERIES DRAWINGS FOR PLUMBING SCOPE. # Revision Date CEILING CLO CLR CLOSET CLEAR CMU COL CONCRETE MASONRY UNIT COLUMN CONC CONF CONCRETE CONFERENCE CONST COORD CONSTRUCTION COORDINATE CORR CPT CORRIDOR CARPET CSI CTR CONSTRUCTION SPECIFICATIONS INSTITUTE CENTER CU FT CU IN CUBIC FEET CUBIC INCH CUST CW CUSTODIAN CURTAINWALL DBL DEFS DOUBLE DIRECT-APPLIED FINISH SYSTEM DEG DEMO DEGREE DEMOLITION DEPT DET DEPARTMENT DETAIL DF DH DRINKING FOUNTAIN DOUBLE HUNG (DOOR, WINDOW) DIA DIAG DIAMETER DIAGONAL DIM DISP DIMENSION DISPENSER DIV DN DIVISION DOWN DS DWG DOWN SPOUT DRAWING EA EACH EC EIFS ELECTRICAL CONTRACTOR EXTERIOR INSULATION AND FINISH SYSTEM EJ EL/ELEV EXPANSION JOINT ELEVATION ELEC ELEV ELECTRIC ELEVATOR EOS EPDM EDGE OF SLAB ETHYLENE PROPYLENE DIENE MONOMER EQ EQUIP EQUAL EQUIPMENT EST ETC ESTIMATE ET CETERA EXIST EXISTING FD FE FLOOR DRAIN FIRE EXTINGUISHER FEC FIN FIRE EXTINGUISHER CABINET FINISH FIN FLR FIN GR FINISH FLOOR FINISH GRADE FIXT FLASH FIXTURE FLASHING FLR FR FLOOR FIRE RESISTANT FRC FRG FIBER REINFORCED CONCRETE FIBER REINFORCED GYPSUM FRP FRZ FIBERGLASS REINFORCED PLASTIC FREEZER FT FTG FEET, FOOT FOOTING FURG FURRING FURN FWC FURNITURE FABRIC WALL COVERING GA GAL GAUGE GALLON GALV GC GALVANIZED GENERAL CONTRACTOR GFRC GFRG GLASS-FIBER-REINFORCED CONCRETE GLASS-FIBER-REINFORCED GYPSUM GFRP GLASS-FIBER-REINFORCED PLASTER GL BLK GLU LAM GLASS BLOCK GLUE LAMINATED WOOD GOVT GWB GOVERNMENT GYPSUM WALLBOARD HAZ HAZ MAT HAZARD HAZARDOUS MATERIALS HDBD HDW HEAVY DUTY HARDBOARD HARDWARE HM HOLLOW METAL HORIZ HR HORIZONTAL HOUR HT HVAC HEIGHT HEATING, VENTILATION, AND AIR CONDITIONING IBC INTERNATIONAL BUILDING CODE ID INSIDE DIAMETER IN INSTR INCH/ INCHES INSTRUMENT INSUL INT INSULATION, E, (ED) INTERIOR JAN JANITOR KD KNOCK DOWN KIT KO KITCHEN KNOCKOUT LAM LG LAMINATE LAMINATED GLASS LAV LED LAVATORY LIGHT EMITTING DIODE LF LINEAR FEET (FOOT) LKR RM LRG LOCKER ROOM LARGE LT LT GA LIGHT LIGHT GAUGE MAINT MAN MAINTENANCE MANUAL MATL MAX MATERIAL MAXIMUM MB MC MARKER BOARD MECHANICAL CONTRACTOR MDO MECH MEDIUM DENSITY OVERLAY MECHANICAL MED MEMB MEDIUM MEMBRANE MEP MEZZ MECHANICAL, ELECTRICAL, PLUMBING MEZZANINE MFD MFG MANUFACTURED MANUFACTURING MFR MGT MANUFACTURER MANAGEMENT MIN MISC MINIMUM MISCELLANEOUS ML MO METAL LATH MASONRY OPENING MT MTD MOUNT MOUNTED MTG MTL MOUNTING METAL MULL MULLION NA NIC NOT APPLICABLE NOT IN CONTRACT NO NOM NUMBER NOMINAL NTS NOT TO SCALE O/O OC OUT TO OUT ON CENTER OD OPG OUTSIDE DIAMETER OPENING OPP ORIG OPPOSITE ORIGINAL OSHA OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION PART PBD PARTIAL PARTICLEBOARD PERF PKG PERFORATED PACKAGE PLAS LAM PLYWD PLASTIC LAMINATE PLYWOOD PNL PORC PANEL PORCELAIN PR PREFAB PAIR PREFABRICATED PREFIN PREP PREFINISH PREPARATION PROJ PT PROJECT PAINT R RCP RADIUS REFLECTED CEILING PLAN RD REBAR ROOF DRAIN REINFORCING STEEL BARS RECPT REF RECEPTACLE REFERENCE REF REINF REFRIGERATOR REINFORCED REQD REST REQUIRED RESTROOM RM RO ROOM ROUGH OPENING RTG RTU RATING ROOF TOP UNIT SCHED SCHEM SCHEDULE SCHEMATIC SCWD SECT SOLID CORE WOOD DOOR SECTION SF SHR SQUARE FOOT (FEET) SHOWER SHT SIM SHEET SIMILAR SM SPEC SMALL SPECIFICATION SPKLR SQ SPRINKLER SQUARE SQ YD SS SQUARE YARD STAINLESS STEEL ST STD STREET STANDARD STL STOR STEEL STORAGE STRUCT SURR STRUCTURAL SURROUND SUSP SUSPEND SUSP CLG SUSPENDED CEILING SV SVC SHEET VINYL SERVICE SYS SYSTEM T&G T/O TONGUE AND GROOVE TOP OF TB TD TACK BOARD TOWEL DISPENSER TECH TEMP TECHNICAL TEMPORARY TFF TG TOP OF FINISHED FLOOR TEMPERED GLASS THK THICKNESS THRU THROUGH TI TOS TAPERED INSULATION TOP OF STEEL TOM TOP OF MASONRY TRANS TRANSOM TYP TYPICAL UL UNDERWRITERS LABORATORIES UNO UNLESS NOTED OTHERWISE UPS UNINTERRUPTIBLE POWER SUPPLY UTIL UTILITY VAR VB VARIES VINYL BASE VCT VEH VINYL COMPOSITION TILE VEHICLE VERT VERTICAL VEST VESTIBULE VIF VOL VERIFY IN FIELD VOLUME VR VAPOR RETARDER VWC VINYL WALL COVERING VWF VINYL WALL FABRIC W/ WITH W/O WC WITHOUT WALL COVERING WD WOOD WP WORKING POINT WT WEIGHT SINK LAVATORY TOILET SUPPLY AIR RETURN AIR EXIT LIGHT LIGHT FIXTURE IN CEILING GRID ROOF/OVERFLOW DRAIN FLOOR DRAIN URINAL Component Symbols DOUBLE SINGLE UTILITY COUNTERTOP WALL HUNG WALL HUNG FLOOR MOUNT 2 GANG 3 GANG CONCRETE MASONRY UNIT FACE BRICK EARTH CONCRETE PLYWOOD METAL/STEEL FINISHED WOOD TRIM WOOD BLOCKING WOOD SHIM INSULATION (LOOSE OR BATT.) INSULATION (RIGID) GYPSUM BOARD / PLASTER Material Symbols TITLE MARK SECTION MARK ELEVATION MARK CUT LINE DETAIL MARK PLAN NOTE DESIGNATION WHEELCHAIR CLEARANCE RADIUS WALL DESIGNATION WINDOW NUMBER FURNITURE COLUMN DESIGNATION NORTH ARROW ROOM TAG UNIT MATCHLINE DEMOLITION NOTE DATUM POINT 1 View Name 1/8" = 1'-0" ADA 1t 1t FM N Room name 101 Reference Symbols FB FB REVISION TAG UNIT A UNIT B # 1 A101 SIM A101 R1ef 1 Ref 1 Ref R1ef SHEET REFERENCE DETAIL REFERENCE A101 1 SIM # DOOR NUMBER Door Label Door Number Hardware Set Panel Type 101 45 min FG 168 HM23A=HM# KEYNOTE LABEL 00 00 00.B9 Specification Reference Unique Identifier (Not A Reference) REFLECTED CEILING PLAN LEGEND APC-1 2' X 2' Acoustical Panel Ceiling (09 51 13) GWB 5/8" GWB on Grid Suspension System (09 22 16) Walls to Deck Light Fixture (Reference E-Series Dwgs) Return Air (Reference M-Series Dwgs) Supply Air (Reference M-Series Dwgs) Exit Light (Reference E-Series Dwgs) Recessed Light Fixture Suspended Fixture in Areas with Exposed Ceilings (Reference E-Series Dwgs) S SOUND SYSTEM SPEAKER (REFERENCE E-SERIES/T- SERIES DWGS) A. Comply with all applicable codes and regulations pertaiting to this scope of work. B. All products to be handled, stored, and installed per manufacturer requirements. C. All dimensions shown are to face of stud or masonry, unless noted otherwise. Dimensions designated as "CLR or "clear" indicate a clear dimension from face of finish to face of finish. Dimensions of exterior walls are to outside edge of foundation. D. All openings for Mechanical, Plumbing, Fire Protection and Electrical shall be fire stopped at each floor penetration. E. Dimensional Lumber shall be Construction or No 2 Grade. Any concealed lumber in contact with concrete or masonry shall be preservative treated according to AWPA C2. F. Provide bracing and blocking as required in walls supporting casework, tackboards, markerboards, and restroom accessories. Blocking shall be solid wood minimum 3/4" x 6" wide. G. All door frames are located 4" from adjacent wall, unless noted otherwise. H. All exposed outside corners of CMU shall be bullnosed. I. Seal all joints between dissimilar materials with nonstaining sealant apropriate for both materials and application. J. All gypsum wallboard is 5/8" Type "X", unless noted otherwise. K. Where new floors meet existing floors, a smooth, straight, and flush transition shall be constructed. Verify in field existing floor elevations and conditions where a new floor shall be constructed adjacent. Trim and patch existing floor as required to achieve desired transition. L. All interior walls are Type "S4-C", unless noted otherwise. M. Refer to C Series drawings for base elevation height (0'-0") relative to USGS (United States Geological Survey data). N. Hatching within walls shown in plans and sections indicates new construction. M. Loose furniture is not provided in this contract. General Plan Notes A. Contractor shall field-verify all existing conditions, dimensions, and arrangements. B. Contractor is responsible for protection of all existing surfaces, materials, and components to remain or be relocated. Damage to these resulting from performance of Work shall be repaired by Contractor to satisfaction of Owner and Architect at no additional expense to Owner. C. Contractor shall provide temporary dust protection as required to prevent construction debris and dust from migrating out of Project Area. Owner/Architect shall confirm all dust prevention measures/locations and shall determine changes to these measures. D. All existing equipment and fixtures shall remain property of Owner. All reusable items salvaged during demolition operations shall be retained for Owner's inspection. Only items so inspected and rejected by Owner shall be disposed. All other such items shall be turned over to Owner for disposition. E. All existing surfaces located adjacent to, or exposed by demolition work and scheduled to receive new construction shall be patched and repaired as required to cleanly receive new work. F. All existing surfaces located adjacent to, or exposed by demolition work and scheduled to remain exposed after completion of new const. shall be repaired and patched as required to receive new finishes. G. Owner will be responsible for removal/rearrangement of all existing loose furnishings during construction, unless noted otherwise. H. Refer to Mech./Elec. Drawings for additional patching and preparation work related to M.E.P. demolition items. I. Existing sleeves, holes, and other penetrations or new damage of existing building structure above grade exposed by demolition and removal of piping, appurtenances, equipment shall be patched and repaired as part of the Work. Maintain fire ratings of all and adjacent construction affected. J. Cap all piping to remain or abandoned in accordance with requirements of authority having jurisdiction and in accordance with all local and state plumbing and health codes. Utilize only pre-manufactured and approved fittings to cap existing piping. K. Each Contractor is responsible for all demolition work required or noted for installation of new Work. Demolition may include associated distribution systems, appurtenances, equipment supporting controls, and miscellaneous supports, unless noted otherwise. L. Coordinate all demolition with Project sequencing as directed by General Contractor or Construction Manager. General Demolition Notes A. All ceilings are at 10'-0" AFF, unless noted otherwise. B. All bulkheads are at 9'-10" AFF, unless noted otherwise. C. All grids are centered in rooms, unless noted otherwise. D. All exposed ductwork, piping etc. shall be painted. Color selected by Architect. E. Locate sprinkler heads in center of ceiling panel - where applicable. F. Bulkheads to receive paint, P-1, in its entirety unless otherwise noted. General Refl. Ceiling Plan Notes N 6 5 4 3 2 1 A B C D E 6 5 4 3 2 1 A B C D E Project No. Project Date Produced These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect. KEY PLAN B A 5/22/2023 2:31:33 PM C:\_RevitLocal\2023-067.POR_Bldg001_A_2023\2023-067.POR_Bldg001_A_2023_mmiller.rvt 2023-067.POR 05.22.2023 ARCHITECTURAL GENERAL NOTES AND ABBREVIATIONS A-001 MW Coram Deo Academy Phase One Renovations 2023-067.POR_Coram Deo Academy_Phase One Renovations_ 525 Congressional Blvd, Carmel, IN 46032 A-001_ ARCHITECTURAL GENERAL NOTES AND ABBREVIATIONS # Revision Date # of Exits: 1 EGRESS AREA: 3284 SF Unconcentrated CHAPEL B111 Load: 361 # of Exits: 3 EGRESS AREA: 1778 SF Classroom CLASSROOM B115 Load: 89 # of Exits: 2 EGRESS AREA: 2170 SF Exercise room GYM A110 Load: 44 # of Exits: 1 937 SF CLASSROOM EGRESS AREA: 772 SF Classroom CLASSROOM A116 Load: 39 # of Exits: 1 EGRESS AREA: 965 SF Classroom SCIENCE LAB A121 Load: 48 # of Exits: 1 EGRESS AREA: 406 SF Classroom PRE-K B132 Load: 24 # of Exits: 1 544 SF CLASSROOM EGRESS AREA: 582 SF Reading room LIBRARY B135 Load: 12 # of Exits: 1 1167 SF CLASSROOM 525 SF CLASSROOM 606 SF CLASSROOM 581 SF CLASSROOM 477 SF CLASSROOM 715 SF BREAK ROOM EGRESS AREA: 449 SF Classroom CLASSROOM A120 Load: 22 # of Exits: 1 1306 SF STORAGE 246 SF STORAGE 280 SF ELECTRICAL 167 SF UNOCCUPIED 175 SF UNOCCUPIED 168 SF UNOCCUPIED 168 SF UNOCCUPIED 175 SF UNOCCUPIED 168 SF UNOCCUPIED 134 SF UNOCCUPIED 200 SF UNOCCUPIED 200 SF UNOCCUPIED 198 SF OFFICE 146 SF STORAGE 144 SF OFFICE 173 SF OFFICE 219 SF OFFICE 108 SF OFFICE 227 SF WOMENS RR 297 SF MENS RR 248 SF MENS RR 251 SF WOMENS RR 125 SF OFFICE 111 SF OFFICE 116 SF OFFICE 90 SF OFFICE 199 SF STORAGE 101 SF PRACTICE ROOM 107 SF PRACTICE ROOM 164 SF PRACTICE ROOM 165 SF OFFICE 118 SF STORAGE 118 SF STORAGE 195 SF RR 115 SF VESTIBULE 41 SF RISER RM 27 SF JANITOR 137 SF STORAGE 206 SF CLINIC 81 SF STORAGE 90 SF COPIER 115 SF OFFICE 129 SF OFFICE 172 SF WOMENS RR 300 SF STORAGE 170 SF MENS RR 175 SF OFFICE 108 SF PLUMBING 107 SF KITCHENETTE EGRESS AREA: 1490 SF Classroom COMMONS B141 Load: 74 # of Exits: 2 152 SF STORAGE 169 SF STORAGE 177 SF STORAGE 241 SF STORAGE 165 SF STORAGE 205 SF STORAGE 73 SF RR 161 SF OFFICE 78 SF KITCHENETTE 535 SF PARENT ROOM 508 SF LOBBY EGRESS AREA: 2196 SF Unconcentrated CAFETERIA B111A Load: 361 # of Exits: 3 116 SF OFFICE 127 SF OFFICE 30 SF STORAGE B126 31' - 6" B126 26' - 6" B126 23' - 6" B126 25' - 0" A116 18' - 6" A116 15' - 5" A116 37' - 0" A116 17' - 0" A116 32' - 2" A116 20' - 5" B111A.1 21' - 6" B111A.1 17' - 0" B111A.1 18' - 2" B111A.1 40' - 6" B111A.1 7' - 0" B111A.1 33' - 0" B111A.1 16' - 0" B111 29' - 2" B111 55' - 3" B111 3' - 6" B111A.2 32' - 4" B111A.2 40' - 1" B111A.2 14' - 0" B111A.2 41' - 6" B111A.2 50' - 0" B111A.2 29' - 0" B111A.2 15' - 11" NRIU EGRESS Room name 101 AREA: 150 SF Load: ## # of Exits: # Occupancy 1-HOUR FB RATED WALL 2-HOUR FB RATED WALL 4-HOUR FB RATED WALL LOCK BOX ANNUNCIATOR PANEL LIFE SAFETY PLAN LEGEND EGRESS INFORMATION TAG FIRE EXTINGUISHER (NOT REQUIRED) NON-RATED INCIDENTAL-USE WALL [508.2.2.1] 1-HOUR FIRE PARTITION [419, 1017.1] FIRE HOSE CABINET N 6 5 4 3 2 1 A B C D E 6 5 4 3 2 1 A B C D E Project No. Project Date Produced These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect. KEY PLAN B A 5/22/2023 3:09:35 PM C:\_RevitLocal\2023-067.POR_Bldg001_A_2023\2023-067.POR_Bldg001_A_2023_mmiller.rvt 2023-067.POR 05.22.2023 FIRE AND LIFE SAFETY PLAN G-100 MW Coram Deo Academy Phase One Renovations 2023-067.POR_Coram Deo Academy_Phase One Renovations_ 525 Congressional Blvd, Carmel, IN 46032 G-100_ FIRE AND LIFE SAFETY PLAN 2A 1/16" = 1'-0" FIRE AND LIFE SAFETY FLOOR PLAN INTERIOR FINISHES: MEANS OF EGRESS: Emergency lighting is required in all corridors, rooms, spaces that require more than one means of egress or exit. [1006.3] EMERGENCY AND EGRESS LIGHTING: Exit signs required to indicate the direction of egress travel for rooms and areas that require more than one exit access. [1011.1] PANIC HARDWARE: Panic hardware is required on latching doors serving rooms or spaces with an occupant load of 50 or more in an A or E occupancy. [1008.1.10] DOOR SWING: Exit doors must swing in the direction of egress when serving 50 or more occupants. Exit doors are required to be side - hinged swinging type, except for office or storage areas with an occupant load of less than 10. [1008.1.2] CORRIDORS: Egress corridors are permitted to be nonrated based upon automatic sprinkler protection throughout [1018.1] Unconcentrated assembly use: 15 sq. ft./occ. [Table 1004.1.2] Library Reading Rooms: 50 sq. ft/occ. Exercise Rooms: 50 sq. ft/occ. Offices: 100 sq. ft./occ. OCCUPANT LOAD FACTORS: Classrooms: 20 sq. ft./occ. FIRE DAMPERS: Not Required Fire and/or smoke dampers are not required in duct penetrations of these separations Boiler and furnace rooms with equipment sized as indicated in Table 509 [Table 509, Sec. 509.4.2] INCIDENTAL USE SEPARATION: Walls for these areas are required to terminate at the deck or a 1-hour ceiling, with self-closing doors B Occupancy office areas are not required to be separated based upon compliance as accessory occupancy [508.2] OCCUPANCY SEPARATIONS: Occupancy separations not required, based upon classification of assembly uses accessory to an educational occupancy as E Occupancy areas [303.1.3] ALLOWABLE AREA: Unlimited Area based on E Occupancy clasification protected throughout with an automatic sprinkler system and surrounded by at least 60 feet of open space. [507.3] ALLOWABLE HEIGHT: 2 stories permitted, 1 story actual [507.4] CONSTRUCTION TYPE: Type IIB Existing Construction Office - accessory occupancy less than 10% of the building area - B Occupancy [304.1, 508.2] Assembly uses accessory to Group E are not considered separate occupancies [303.1.3] - E Occupancy [305.1, 303.1.3] OCCUPANCY SEPARATIONS: Educational use and assembly areas associated with the E Occupancy CODE STRATEGY: Existing egress pathways and fire supression will be maintained through this renovation. The existing building will remain as an unlimited area building. Building will remain in operation throughout construction; egress pathways will be maintained throughout construction. SCOPE OF WORK: Phase 1 project scope includes selective interior renovations of the existing building, including a new science lab and classroom spaces. *Code referenced unless noted otherwise ICC/ANSI A-117.1 Standard, 2009 Edition 2014 Indiana Fire Code 2010 Indiana Energy Conservation Code 2009 Indiana Electrical Code 2012 Indiana Plumbing Code 2014 Indiana Mechanical Code APPLICABLE CODE: 2014 Indiana Building Code CODE SUMMARY Building Areas Name Area Existing 27383 SF Renovation 19866 SF Total Building Area 47249 SF Egress Travel Distance Schedule Path ID Travel Distance A116 144' B111 88' B111A.1 153' B111A.2 223' B126 107' SHADED REGIONS ARE NO SCOPE ROOMS; ALL EXISTING TO REMAIN. # Revision Date IN1A1 FIRST FLOOR INTERIOR FINISH PLAN IN1B1 FIRST FLOOR INTERIOR FINISH PLAN I-201 INTERIOR ELEVATIONS 7 - Mechanical M-001 MECHANICAL SYMBOLS AND ABBREVIATIONS MD1A1 FIRST FLOOR DEMOLITION PLAN - UNIT A MD1B1 FIRST FLOOR DEMOLITION PLAN - UNIT B MH1A1 FIRST FLOOR HVAC PLAN - UNIT A MH1B1 FIRST FLOOR HVAC PLAN - UNIT B MR101 MECHANICAL ROOF PLAN M-501 MECHANICAL DETAILS 8 - Plumbing P-001 PLUMBING SYMBOLS AND ABBREVIATIONS PD1A1 LEVEL 1 DEMOLITION PLUMBING PLAN - UNIT A FP101 LEVEL 1 FIRE PROTECTION PLUMBING PLAN PF1A1 FOUNDATION PLUMBING PLANS - UNIT A - ALTERNATE PP1A1 LEVEL 1 PLUMBING PLANS - UNIT A PP1A2 LEVEL 1 PLUMBING PLANS - UNIT A - ALTERNATE PR101 ROOF LEVEL PLUMBING PLAN - ALTERNATE P-501 PLUMBING DETAILS P-901 PLUMBING ISOMETRIC 9 - Electrical E-001 SYMBOLS & ABBREVIATIONS E-002 GENERAL INFORMATION E-101 OVERAL BUILDING PLAN ED1A1 FIRST FLOOR DEMOLITION PLAN - UNIT A ED1B1 FIRST FLOOR DEMOLITION PLAN - UNIT B EL1A1 FIRST FLOOR LIGHTING PLAN - UNIT A EL1B1 FIRST FLOOR LIGHTING PLAN - UNIT B EP1A1 FIRST FLOOR POWER PLAN - UNIT A EP1B1 FIRST FLOOR POWER PLAN - UNIT B E-501 GENERAL DETAILS E-601 LIGHTING AND EQUIPMENT SCHEDULES ALTERNATES: • ROOM B137 ALTERNATE • SCIENCE LAB ALTERNATE • MUSIC DOOR ALTERNATE • GYMNASIUM WALL ALTERNATE The cost or credit for each alternate is the net addition to or deduction from the Contract Sum to incorporate alternate into the Work. No other adjustments are made to the Contract Sum. Include as part of each alternate, miscellaneous devices, accessory objects, and similar items incidental to or required for a complete installation whether or not indicated as part of alternate. Work that is provided under the alternates shall comply with all applicable provisions of the Contract Documents