HomeMy WebLinkAboutCoram Deo Prints 5.22.23General NotesNothing set forth in these Drawings shall release any Contractor from responsibility to provide appropriate quantities, field measurements, dimensional stability, installation, anchorage and coordination with other trades, or waive the Contractor's responsibility to identify and resolve deviations from the requirements of the Contract Documents, or waive the Contractor's responsibility to alert the Architect to errors or omissions contained therein.Each Contractor shall verify in the field all existing applicable conditions and dimensions shown on the Drawings and as pertinent to the intent of these Drawings. Any discrepancy discovered shall be brought to the attention of the Architect prior to the commencement of any Work affected by, or related to, such discrepancy.Each Contractor shall be responsible for all costs associated with, or caused by failure to comply with requirement.Each Contractor shall review in advance all portions of the Work to verify that the Work will not prohibit completion of the Project as intended in these Contract Documents. Any questions shall be promptly referred to the Architect for resolution.Vicinity MapThoroughfare MapEach Contractor shall refer to the Project Manual for cleaning and disposal requirements.Each Contractor shall be responsible for the protection of all surfaces and finishes at interior and exterior of building. Damaged surfaces and finishes resulting from the performance of the Work shall be repaired at no cost to the Owner by the responsible Contractor to match existing to the satisfaction of the Owner.Each Contractor shall coordinate respective cutting and patching Work with the other Prime Contracts.Each Contractor shall become completely familiar with all aspects of the Work, even those areas designated to be provided by others. This familiarization includes full and complete understanding of the Work described on all Sheets of the Drawings and in all Sections of the Project Manual. Failure by the Contractor to become completely familiar and cognizant of all aspects of the Work shall not relieve the Contractor of the responsibility to provide materials, assemblies, or services indicated in the Contract Documents.2023-067.POR05.22.2023Phase One RenovationsCoram Deo AcademyCoram Deo AcademyPhase One Renovations525 Congressional Blvd,Carmel, IN 460322023-067.PORG-001SHEET INDEXNumberSheet Name1 - GeneralG-001COVER SHEETG-100FIRE AND LIFE SAFETY PLAN2 - SiteCL101SITE LAYOUT PLAN4 - ArchitecturalA-001ARCHITECTURAL GENERAL NOTES AND ABBREVIATIONSAD1A1DEMOLITION FLOOR PLAN - UNIT AAD1B1DEMOLITION FLOOR PLAN - UNIT BAF101OVERALL FIRST FLOOR PLANAF1A1FIRST FLOOR PLAN - UNIT AAF1B1FIRST FLOOR PLAN - UNIT BAC1A1FIRST FLOOR REFLECTED CEILING PLAN - UNIT AAC1B1FIRST FLOOR REFLECTED CEILING PLAN - UNIT BA-600SCHEDULES & DETAILS5 - InteriorsIN1A1FIRST FLOOR INTERIOR FINISH PLANIN1B1FIRST FLOOR INTERIOR FINISH PLANI-201INTERIOR ELEVATIONS7 - MechanicalM-001MECHANICAL SYMBOLS AND ABBREVIATIONSMD1A1FIRST FLOOR DEMOLITION PLAN - UNIT AMD1B1FIRST FLOOR DEMOLITION PLAN - UNIT BMH1A1FIRST FLOOR HVAC PLAN - UNIT AMH1B1FIRST FLOOR HVAC PLAN - UNIT BMR101MECHANICAL ROOF PLANM-501MECHANICAL DETAILS8 - PlumbingP-001PLUMBING SYMBOLS AND ABBREVIATIONSPD1A1LEVEL 1 DEMOLITION PLUMBING PLAN - UNIT AFP101LEVEL 1 FIRE PROTECTION PLUMBING PLANPF1A1FOUNDATION PLUMBING PLANS - UNIT A - ALTERNATEPP1A1LEVEL 1 PLUMBING PLANS - UNIT APP1A2LEVEL 1 PLUMBING PLANS - UNIT A - ALTERNATEPR101ROOF LEVEL PLUMBING PLAN - ALTERNATEP-501PLUMBING DETAILSP-901PLUMBING ISOMETRIC9 - ElectricalE-001SYMBOLS & ABBREVIATIONSE-002GENERAL INFORMATIONE-101OVERAL BUILDING PLANED1A1FIRST FLOOR DEMOLITION PLAN - UNIT AED1B1FIRST FLOOR DEMOLITION PLAN - UNIT BEL1A1FIRST FLOOR LIGHTING PLAN - UNIT AEL1B1FIRST FLOOR LIGHTING PLAN - UNIT BEP1A1FIRST FLOOR POWER PLAN - UNIT AEP1B1FIRST FLOOR POWER PLAN - UNIT BE-501GENERAL DETAILSE-601LIGHTING AND EQUIPMENT SCHEDULESALTERNATES:• ROOM B137 ALTERNATE• SCIENCE LAB ALTERNATE• MUSIC DOOR ALTERNATE• GYMNASIUM WALL ALTERNATEThe cost or credit for each alternate is the net addition to or deduction from the Contract Sum to incorporate alternate into the Work.No other adjustments are made to the Contract Sum. Include as part of each alternate, miscellaneous devices, accessory objects, and similar items incidental to or required for a complete installation whether or not indicated as part of alternate.Work that is provided under the alternates shall comply with all applicable provisions of the Contract Documents MHMHMMARARARARTTTTTTDNEGRESSAREA: 671 SFClassroomCLASSROOMB130Load: 34# of Exits: 1EGRESSAREA: 674 SFClassroomCLASSROOMB126Load: 31# of Exits: 1EGRESSAREA: 630 SFClassroomCLASSROOMB121Load: 22# of Exits: 1559 SFCLASSROOMEGRESSAREA: 543 SFClassroomCLASSROOMB127Load: 27# of Exits: 1EGRESSAREA: 525 SFClassroomCLASSROOMB145Load: 26# of Exits: 1449 SFCLASSROOMEGRESSAREA: 538 SFClassroomCLASSROOMB137Load: 27# of Exits: 1EGRESSAREA: 3284 SFUnconcentratedCHAPELB111Load: 361# of Exits: 3EGRESSAREA: 1778 SFClassroomCLASSROOMB115Load: 89# of Exits: 2EGRESSAREA: 2170 SFExercise roomGYMA110Load: 44# of Exits: 1937 SFCLASSROOMEGRESSAREA: 772 SFClassroomCLASSROOMA116Load: 39# of Exits: 1EGRESSAREA: 965 SFClassroomSCIENCE LABA121Load: 48# of Exits: 1EGRESSAREA: 406 SFClassroomPRE-KB132Load: 24# of Exits: 1544 SFCLASSROOMEGRESSAREA: 582 SFReading roomLIBRARYB135Load: 12# of Exits: 11167 SFCLASSROOM525 SFCLASSROOM606 SFCLASSROOM581 SFCLASSROOM477 SFCLASSROOM715 SFBREAK ROOMEGRESSAREA: 449 SFClassroomCLASSROOMA120Load: 22# of Exits: 11306 SFSTORAGE246 SFSTORAGE280 SFELECTRICAL167 SFUNOCCUPIED175 SFUNOCCUPIED168 SFUNOCCUPIED168 SFUNOCCUPIED175 SFUNOCCUPIED168 SFUNOCCUPIED134 SFUNOCCUPIED200 SFUNOCCUPIED200 SFUNOCCUPIED198 SFOFFICE146 SFSTORAGE144 SFOFFICE173 SFOFFICE219 SFOFFICE108 SFOFFICE227 SFWOMENS RR297 SFMENS RR248 SFMENS RR251 SFWOMENS RR125 SFOFFICE111 SFOFFICE116 SFOFFICE90 SFOFFICE199 SFSTORAGE101 SFPRACTICEROOM107 SFPRACTICEROOM164 SFPRACTICEROOM165 SFOFFICE118 SFSTORAGE118 SFSTORAGE195 SFRR115 SFVESTIBULE41 SFRISER RM27 SFJANITOR137 SFSTORAGE206 SFCLINIC81 SFSTORAGE90 SFCOPIER115 SFOFFICE129 SFOFFICE172 SFWOMENS RR300 SFSTORAGE170 SFMENS RR175 SFOFFICE108 SFPLUMBING107 SFKITCHENETTEEGRESSAREA: 1490 SFClassroomCOMMONSB141Load: 74# of Exits: 2152 SFSTORAGE169 SFSTORAGE177 SFSTORAGE241 SFSTORAGE165 SFSTORAGE205 SFSTORAGE73 SFRR161 SFOFFICE78 SFKITCHENETTE535 SFPARENTROOM508 SFLOBBYEGRESSAREA: 2196 SFUnconcentratedCAFETERIAB111ALoad: 361# of Exits: 3116 SFOFFICE127 SFOFFICE30 SFSTORAGEB12631' -6"B12626' -6"B12623' -6"B12625' -0"A11618' -6"A11615' -5"A11637' -0"A11617' -0"A11632' -2"A11620' -5"B111A.121' -6"B111A.117' -0"B111A.118' -2"B111A.140' -6"B111A.17' -0"B111A.133' -0"B111A.116' -0"B11129' -2"B11155' -3"B1113' -6"B111A.232' -4"B111A.240' -1"B111A.214' -0"B111A.241' -6"B111A.250' -0"B111A.229' -0"B111A.215' -11"NRIUEGRESSRoom name101AREA: 150 SFLoad: ### of Exits: #Occupancy1-HOUR FB RATED WALL2-HOUR FB RATED WALL4-HOUR FB RATED WALLLOCK BOXANNUNCIATOR PANELLIFE SAFETY PLAN LEGENDEGRESS INFORMATION TAGFIRE EXTINGUISHER (NOT REQUIRED)NON-RATED INCIDENTAL-USE WALL [508.2.2.1]1-HOUR FIRE PARTITION [419, 1017.1]FIRE HOSE CABINETN123456ABCDE123456ABCDEProject No.Project DateProducedThese Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect.KEY PLANBA5/22/2023 3:09:35 PMC:\_RevitLocal\2023-067.POR_Bldg001_A_2023\2023-067.POR_Bldg001_A_2023_mmiller.rvt2023-067.POR05.22.2023FIRE AND LIFE SAFETYPLANG-100MWCoram DeoAcademyPhase OneRenovations2023-067.POR_Coram Deo Academy_Phase One Renovations_525 Congressional Blvd,Carmel, IN 46032G-100_ FIRE AND LIFE SAFETY PLAN1/16" = 1'-0"2AFIRE AND LIFE SAFETY FLOOR PLANINTERIOR FINISHES:MEANS OF EGRESS:Emergency lighting is required in all corridors, rooms, spaces that require more thanone means of egress or exit. [1006.3]EMERGENCY ANDEGRESS LIGHTING:Exit signs required to indicate the direction of egress travel for rooms and areas thatrequire more than one exit access. [1011.1]PANIC HARDWARE:Panic hardware is required on latching doors serving rooms or spaces with anoccupant load of 50 or more in an A or E occupancy. [1008.1.10]DOOR SWING:Exit doors must swing in the direction of egress when serving 50 or more occupants.Exit doors are required to be side - hinged swinging type, except for office or storageareas with an occupant load of less than 10. [1008.1.2]CORRIDORS:Egress corridors are permitted to be nonrated based upon automatic sprinklerprotection throughout [1018.1]Unconcentrated assembly use: 15 sq. ft./occ. [Table 1004.1.2]Library Reading Rooms: 50 sq. ft/occ.Exercise Rooms: 50 sq. ft/occ.Offices: 100 sq. ft./occ.OCCUPANT LOADFACTORS:Classrooms: 20 sq. ft./occ.FIRE DAMPERS:Not RequiredFire and/or smoke dampers are not required in duct penetrations of these separationsBoiler and furnace rooms with equipment sized as indicated in Table 509 [Table 509,Sec. 509.4.2]INCIDENTAL USESEPARATION:Walls for these areas are required to terminate at the deck or a 1-hour ceiling, withself-closing doorsB Occupancy office areas are not required to be separated based upon compliance asaccessory occupancy [508.2]OCCUPANCYSEPARATIONS:Occupancy separations not required, based upon classification of assembly usesaccessory to an educational occupancy as E Occupancy areas [303.1.3]ALLOWABLE AREA:Unlimited Area based on E Occupancy clasification protected throughout with anautomatic sprinkler system and surrounded by at least 60 feet of open space. [507.3]ALLOWABLE HEIGHT:2 stories permitted, 1 story actual [507.4]CONSTRUCTION TYPE:Type IIB Existing ConstructionOffice - accessory occupancy less than 10% of the building area - B Occupancy [304.1, 508.2]Assembly uses accessory to Group E are not considered separate occupancies[303.1.3]- E Occupancy [305.1, 303.1.3]OCCUPANCYSEPARATIONS:Educational use and assembly areas associated with the E OccupancyCODE STRATEGY:Existing egress pathways and fire supression will be maintained through thisrenovation. The existing building will remain as an unlimited area building. Building willremain in operation throughout construction; egress pathways will be maintainedthroughout construction.SCOPE OF WORK:Phase 1 project scope includes selective interior renovations of the existing building,including a new science lab and classroom spaces.*Code referenced unless noted otherwiseICC/ANSI A-117.1 Standard, 2009 Edition2014 Indiana Fire Code2010 Indiana Energy Conservation Code2009 Indiana Electrical Code2012 Indiana Plumbing Code2014 Indiana Mechanical CodeAPPLICABLE CODE:2014 Indiana Building CodeCODE SUMMARYBuilding AreasNameAreaExisting27383 SFRenovation19866 SFTotal Building Area47249 SFEgress Travel Distance SchedulePath IDTravel DistanceA116144'B11188'B111A.1153'B111A.2223'B126107'SHADED REGIONS ARE NO SCOPE ROOMS; ALL EXISTING TO REMAIN.#RevisionDate AbbreviationsA/EADAARCHITECT/ENGINEERAMERICANS WITH DISABILITIES ACTADDADJADDENDUMADJACENTADMINAFFADMINISTRATIONABOVE FINISHED FLOORALUMAPPROXALUMINUMAPPROXIMATEAPCAPTACOUSTICAL PANEL CEILINGAPARTMENTARCHASSNARCHITECTASSOCIATIONASTMA/VAMERICAN SOCIETY FOR TESTING AND MATERIALSAUDIO/VISUALAVGAWIAVERAGEARCHITECTURAL WOODWORKING INSTITUTEBDBITUMBOARDBITUMINOUSBLDGBLKHDBUILDINGBOTBSMTBOTTOMBASEMENTBULKHEADCABCBCABINETCHALK BOARDCDCDCONSTRUCTION DOCUMENTSCONTRACT DOCUMENTSCIPCJCAST-IN-PLACECONTROL JOINTCLCLGCENTER LINECEILINGCLOCLRCLOSETCLEARCMUCOLCONCRETE MASONRY UNITCOLUMNCONCCONFCONCRETECONFERENCECONSTCOORDCONSTRUCTIONCOORDINATECORRCPTCORRIDORCARPETCSICTRCONSTRUCTION SPECIFICATIONS INSTITUTECENTERCU FTCU INCUBIC FEETCUBIC INCHCUSTCWCUSTODIANCURTAINWALLDBLDEFSDOUBLEDIRECT-APPLIED FINISH SYSTEMDEGDEMODEGREEDEMOLITIONDEPTDETDEPARTMENTDETAILDFDHDRINKING FOUNTAINDOUBLE HUNG (DOOR, WINDOW)DIADIAGDIAMETERDIAGONALDIMDISPDIMENSIONDISPENSERDIVDNDIVISIONDOWNDSDWGDOWN SPOUTDRAWINGEAEACHECEIFSELECTRICAL CONTRACTOREXTERIOR INSULATION AND FINISH SYSTEMEJEL/ELEVEXPANSION JOINTELEVATIONELECELEVELECTRICELEVATOREOSEPDMEDGE OF SLABETHYLENE PROPYLENE DIENE MONOMEREQEQUIPEQUALEQUIPMENTESTETCESTIMATEET CETERAEXISTEXISTINGFDFEFLOOR DRAINFIRE EXTINGUISHERFECFINFIRE EXTINGUISHER CABINETFINISHFIN FLRFIN GRFINISH FLOORFINISH GRADEFIXTFLASHFIXTUREFLASHINGFLRFRFLOORFIRE RESISTANTFRCFRGFIBER REINFORCED CONCRETEFIBER REINFORCED GYPSUMFRPFRZFIBERGLASS REINFORCED PLASTICFREEZERFTFTGFEET, FOOTFOOTINGFURGFURRINGFURNFWCFURNITUREFABRIC WALL COVERINGGAGALGAUGEGALLONGALVGCGALVANIZEDGENERAL CONTRACTORGFRCGFRGGLASS-FIBER-REINFORCED CONCRETEGLASS-FIBER-REINFORCED GYPSUMGFRPGLASS-FIBER-REINFORCED PLASTERGL BLKGLU LAMGLASS BLOCKGLUE LAMINATED WOODGOVTGWBGOVERNMENTGYPSUM WALLBOARDHAZHAZ MATHAZARDHAZARDOUS MATERIALSHDBDHDWHEAVY DUTY HARDBOARDHARDWAREHMHOLLOW METALHORIZHRHORIZONTALHOURHTHVACHEIGHTHEATING, VENTILATION, AND AIR CONDITIONINGIBCINTERNATIONAL BUILDING CODEIDINSIDE DIAMETERININSTRINCH/ INCHESINSTRUMENTINSULINTINSULATION, E, (ED)INTERIORJANJANITORKDKNOCK DOWNKITKOKITCHENKNOCKOUTLAMLGLAMINATELAMINATED GLASSLAVLEDLAVATORYLIGHT EMITTING DIODELFLINEAR FEET (FOOT)LKR RMLRGLOCKER ROOMLARGELTLT GALIGHTLIGHT GAUGEMAINTMANMAINTENANCEMANUALMATLMAXMATERIALMAXIMUMMBMCMARKER BOARDMECHANICAL CONTRACTORMDOMECHMEDIUM DENSITY OVERLAYMECHANICALMEDMEMBMEDIUMMEMBRANEMEPMEZZMECHANICAL, ELECTRICAL, PLUMBINGMEZZANINEMFDMFGMANUFACTUREDMANUFACTURINGMFRMGTMANUFACTURERMANAGEMENTMINMISCMINIMUMMISCELLANEOUSMLMOMETAL LATHMASONRY OPENINGMTMTDMOUNTMOUNTEDMTGMTLMOUNTINGMETALMULLMULLIONNANICNOT APPLICABLENOT IN CONTRACTNONOMNUMBERNOMINALNTSNOT TO SCALEO/OOCOUT TO OUTON CENTERODOPGOUTSIDE DIAMETEROPENINGOPPORIGOPPOSITEORIGINALOSHAOCCUPATIONAL SAFETY AND HEALTH ADMINISTRATIONPARTPBDPARTIALPARTICLEBOARDPERFPKGPERFORATEDPACKAGEPLAS LAMPLYWDPLASTIC LAMINATEPLYWOODPNLPORCPANELPORCELAINPRPREFABPAIRPREFABRICATEDPREFINPREPPREFINISHPREPARATIONPROJPTPROJECTPAINTRRCPRADIUSREFLECTED CEILING PLANRDREBARROOF DRAINREINFORCING STEEL BARSRECPTREFRECEPTACLEREFERENCEREFREINFREFRIGERATORREINFORCEDREQDRESTREQUIREDRESTROOMRMROROOMROUGH OPENINGRTGRTURATINGROOF TOP UNITSCHEDSCHEMSCHEDULESCHEMATICSCWDSECTSOLID CORE WOOD DOORSECTIONSFSHRSQUARE FOOT (FEET)SHOWERSHTSIMSHEETSIMILARSMSPECSMALLSPECIFICATIONSPKLRSQSPRINKLERSQUARESQ YDSSSQUARE YARDSTAINLESS STEELSTSTDSTREETSTANDARDSTLSTORSTEELSTORAGESTRUCTSURRSTRUCTURALSURROUNDSUSPSUSPENDSUSP CLGSUSPENDED CEILINGSVSVCSHEET VINYLSERVICESYSSYSTEMT&GT/OTONGUE AND GROOVETOP OFTBTDTACK BOARDTOWEL DISPENSERTECHTEMPTECHNICALTEMPORARYTFFTGTOP OF FINISHED FLOORTEMPERED GLASSTHKTHICKNESSTHRUTHROUGHTITOSTAPERED INSULATIONTOP OF STEELTOMTOP OF MASONRYTRANSTRANSOMTYPTYPICALULUNDERWRITERS LABORATORIESUNOUNLESS NOTED OTHERWISEUPSUNINTERRUPTIBLE POWER SUPPLYUTILUTILITYVARVBVARIESVINYL BASEVCTVEHVINYL COMPOSITION TILEVEHICLEVERTVERTICALVESTVESTIBULEVIFVOLVERIFY IN FIELDVOLUMEVRVAPOR RETARDERVWCVINYL WALL COVERINGVWFVINYL WALL FABRICW/WITHW/OWCWITHOUTWALL COVERINGWDWOODWPWORKING POINTWTWEIGHTSINKLAVATORYTOILETSUPPLY AIRRETURN AIREXIT LIGHTLIGHT FIXTURE INCEILING GRIDROOF/OVERFLOW DRAINFLOOR DRAINURINALComponent SymbolsDOUBLESINGLEUTILITYCOUNTERTOPWALL HUNGWALL HUNGFLOOR MOUNT3 GANG2 GANGCONCRETE MASONRY UNITFACE BRICKEARTHCONCRETEPLYWOODMETAL/STEELFINISHED WOOD TRIMWOOD BLOCKINGWOOD SHIMINSULATION (LOOSE OR BATT.)INSULATION (RIGID)GYPSUM BOARD / PLASTERMaterial SymbolsTITLE MARKSECTION MARKELEVATION MARKCUT LINEDETAIL MARKPLAN NOTE DESIGNATIONWHEELCHAIR CLEARANCE RADIUSWALL DESIGNATIONWINDOW NUMBERFURNITURECOLUMN DESIGNATIONNORTH ARROWROOM TAGUNIT MATCHLINEDEMOLITION NOTEDATUM POINT1View Name1/8" = 1'-0"ADA1t1tFMNRoom name101Reference SymbolsFBFBREVISION TAGUNIT AUNIT B#1A101SIMA1011Ref1Ref1Ref1RefSHEET REFERENCEDETAIL REFERENCEA1011SIM#DOOR NUMBERDoor LabelDoor NumberHardware SetPanel Type10145 minFG 168HM23A=HM#KEYNOTE LABEL00 00 00.B9SpecificationReferenceUnique Identifier(Not A Reference)REFLECTED CEILING PLAN LEGENDAPC-12' X 2' AcousticalPanel Ceiling (09 51 13)GWB5/8" GWB on Grid Suspension System(09 22 16)Walls to DeckLight Fixture (Reference E-Series Dwgs)Return Air(Reference M-Series Dwgs)Supply Air(Reference M-Series Dwgs)Exit Light(Reference E-Series Dwgs)Recessed Light Fixture Suspended Fixture in Areas with Exposed Ceilings (Reference E-Series Dwgs)SSOUND SYSTEM SPEAKER (REFERENCE E-SERIES/T-SERIES DWGS)A. Comply with all applicable codes and regulations pertaiting to this scope of work.B. All products to be handled, stored, and installed per manufacturer requirements.C. All dimensions shown are to face of stud or masonry, unless noted otherwise. Dimensions designated as "CLR or "clear" indicate a clear dimension from face of finish to face of finish. Dimensions of exterior walls are to outside edge of foundation.D. All openings for Mechanical, Plumbing, Fire Protection and Electrical shall be fire stopped at each floor penetration.E. Dimensional Lumber shall be Construction or No 2 Grade. Any concealed lumber in contact with concrete or masonry shall be preservative treated according to AWPA C2. F. Provide bracing and blocking as required in walls supporting casework, tackboards, markerboards, and restroom accessories. Blocking shall be solid wood minimum 3/4" x 6" wide.G. All door frames are located 4" from adjacent wall, unless noted otherwise.H. All exposed outside corners of CMU shall be bullnosed.I. Seal all joints between dissimilar materials with nonstaining sealant apropriate for both materials and application. J. All gypsum wallboard is 5/8" Type "X", unless noted otherwise.K. Where new floors meet existing floors, a smooth, straight, and flush transition shall be constructed. Verify in field existing floor elevations and conditions where a new floor shall be constructed adjacent. Trim and patch existing floor as required to achieve desired transition.L. All interior walls are Type "S4-C", unless noted otherwise.M. Refer to C Series drawings for base elevation height (0'-0") relative to USGS (United States Geological Survey data).N. Hatching within walls shown in plans and sections indicates new construction.M. Loose furniture is not provided in this contract. General Plan NotesA. Contractor shall field-verify all existing conditions, dimensions, and arrangements.B. Contractor is responsible for protection of all existing surfaces, materials, and components to remain or be relocated. Damage to these resulting from performance of Work shall be repaired by Contractor to satisfaction of Owner and Architect at no additional expense to Owner.C. Contractor shall provide temporary dust protection as required to prevent construction debris and dust from migrating out of Project Area. Owner/Architect shall confirm all dust prevention measures/locations and shall determine changes to these measures.D. All existing equipment and fixtures shall remain property of Owner. All reusable items salvaged during demolition operations shall be retained for Owner's inspection. Only items so inspected and rejected by Owner shall be disposed. All other such items shall be turned over to Owner for disposition.E. All existing surfaces located adjacent to, or exposed by demolition work and scheduled to receive new construction shall be patched and repaired as required to cleanly receive new work.F. All existing surfaces located adjacent to, or exposed by demolition work and scheduled to remain exposed after completion of new const. shall be repaired and patched as required to receive new finishes.G. Owner will be responsible for removal/rearrangement of all existing loose furnishings during construction, unless noted otherwise.H. Refer to Mech./Elec. Drawings for additional patching and preparation work related to M.E.P. demolition items.I. Existing sleeves, holes, and other penetrations or new damage of existing building structure above grade exposed by demolition and removal of piping, appurtenances, equipment shall be patched and repaired as part of the Work. Maintain fire ratings of all and adjacent construction affected.J. Cap all piping to remain or abandoned in accordance with requirements of authority having jurisdiction and in accordance with all local and state plumbing and health codes. Utilize only pre-manufactured and approved fittings to cap existing piping.K. Each Contractor is responsible for all demolition work required or noted for installation of new Work. Demolition may include associated distribution systems, appurtenances, equipment supporting controls, and miscellaneous supports, unless noted otherwise.L. Coordinate all demolition with Project sequencing as directed by General Contractor or Construction Manager.General Demolition NotesA. All ceilings are at 10'-0" AFF, unless noted otherwise.B. All bulkheads are at 9'-10" AFF, unless noted otherwise.C. All grids are centered in rooms, unless noted otherwise.D. All exposed ductwork, piping etc. shall be painted. Color selected by Architect.E. Locate sprinkler heads in center of ceiling panel -where applicable.F. Bulkheads to receive paint, P-1, in its entirety unless otherwise noted. General Refl. Ceiling Plan NotesN123456ABCDE123456ABCDEProject No.Project DateProducedThese Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect.KEY PLANBA5/22/2023 2:31:33 PMC:\_RevitLocal\2023-067.POR_Bldg001_A_2023\2023-067.POR_Bldg001_A_2023_mmiller.rvt2023-067.POR05.22.2023ARCHITECTURALGENERAL NOTES ANDABBREVIATIONSA-001MWCoram DeoAcademyPhase OneRenovations2023-067.POR_Coram Deo Academy_Phase One Renovations_525 Congressional Blvd,Carmel, IN 46032A-001_ ARCHITECTURAL GENERAL NOTES AND ABBREVIATIONS#RevisionDate 678549A21BCDE101112HJKLFGA5E.PE.P060202020403040105050509090808010505010105090501010109090908080101010109080109090808090801010909090901010108080808080808080808030303030303030303030202020202152405MUSIC DOOR ALT.SCIENCE LAB ALT.0404040404042504040404040404040404A. Contractor shall field-verify all existing conditions, dimensions, and arrangements.B. Contractor is responsible for protection of all existing surfaces, materials, and components to remain or be relocated. Damage to these resulting from performance of Work shall be repaired by Contractor to satisfaction of Owner and Architect at no additional expense to Owner.C. Contractor shall provide temporary dust protection as required to prevent construction debris and dust from migrating out of Project Area. Owner/Architect shall confirm all dust prevention measures/locations and shall determine changes to these measures.D. All existing equipment and fixtures shall remain property of Owner. All reusable items salvaged during demolition operations shall be retained for Owner's inspection. Only items so inspected and rejected by Owner shall be disposed. All other such items shall be turned over to Owner for disposition.E. All existing surfaces located adjacent to, or exposed by demolition work and scheduled to receive new construction shall be patched and repaired as required to cleanly receive new work.F. All existing surfaces located adjacent to, or exposed by demolition work and scheduled to remain exposed after completion of new const. shall be repaired and patched as required to receive new finishes.G. Owner will be responsible for removal/rearrangement of all existing loose furnishings during construction, unless noted otherwise.H. Refer to Mech./Elec. Drawings for additional patching and preparation work related to M.E.P. demolition items.I. Existing sleeves, holes, and other penetrations or new damage of existing building structure above grade exposed by demolition and removal of piping, appurtenances, equipment shall be patched and repaired as part of the Work. Maintain fire ratings of all and adjacent construction affected.J. Cap all piping to remain or abandoned in accordance with requirements of authority having jurisdiction and in accordance with all local and state plumbing and health codes. Utilize only pre-manufactured and approved fittings to cap existing piping.K. Each Contractor is responsible for all demolition work required or noted for installation of new Work. Demolition may include associated distribution systems, appurtenances, equipment supporting controls, and miscellaneous supports, unless noted otherwise.L. Coordinate all demolition with Project sequencing as directed by General Contractor or Construction Manager.General Demolition NotesN123456ABCDE123456ABCDEProject No.Project DateProducedThese Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect.KEY PLANBA5/22/2023 2:31:53 PMC:\_RevitLocal\2023-067.POR_Bldg001_A_2023\2023-067.POR_Bldg001_A_2023_mmiller.rvt2023-067.POR05.22.2023DEMOLITION FLOORPLAN -UNIT AAD1A1MWCoram DeoAcademyPhase OneRenovations2023-067.POR_Coram Deo Academy_Phase One Renovations_525 Congressional Blvd,Carmel, IN 46032AD1A1_ DEMOLITION FLOOR PLAN -UNIT A1/8" = 1'-0"1ADEMOLITION FLOOR PLAN -UNIT ADEMOLITION FLOOR PLAN NOTES#NOTE01REMOVE EXISTING INTERIOR WALL CONSTRUCTION IN ITS ENTIRETY TO LIMITSINDICATED INCLUDING, BUT NOT LIMITED TO DOORS, FRAMES, WINDOWS AND ALLMISCELLANEOUS FRAMING. FIELD VERIFY ALL EXISTING WALL CONSTRUCTIONPRIOR TO DEMOLITION. REFER TO ARCHITECTURAL AND INTERIOR FLOOR PLANSFOR FINISH CONDITIONS AND DIMENSIONS. PATCH AND REPAIR EXISTINGADJACENT SURFACES TO REMAIN AND PREP FOR NEW CONSTRUCITON.02BASE BID: EXISTING CARPET TILE TO REMAIN. SCIENCE LAB ALTERNATE: REMOVEEXISTING CARPET FLOOR FINISH IN ITS ENTIRETY TO LIMITS INDICATED INCLUDING,BUT NOT LIMITED TO THE CARPET, ADHESIVES/TACK STRIPS, TRANSITION STRIPSAND ALL ASSOCIATED WALL BASE. SALVAGE CARPET TILES FOR PATCHINGFLOORING IN OTHER LOCATIONS. PATCH AND REPAIR EXISTING SURFACES TOREMAIN AND PREP FOR NEW CONSTRUCTION/FINISH.02REMOVE EXISTING CARPET FLOOR FINISH IN ITS ENTIRETY TO LIMITS INDICATEDINCLUDING, BUT NOT LIMITED TO THE CARPET, ADHESIVES/TACK STRIPS,TRANSITION STRIPS AND ALL ASSOCIATED WALL BASE. SALVAGE CARPET TILESFOR PATCHING FLOORING IN OTHER LOCATIONS. PATCH AND REPAIR EXISTINGSURFACES TO REMAIN AND PREP FOR NEW CONSTRUCTION/FINISH.03EXISTING SUSPENDED ACOUSTICAL CEILING SYSTEM TO REMAIN. PROTECTCEILING SYSTEM AND MODIFY CEILING SYSTEM AS REQUIRED FOR NEWCONSTRUCTION.04REMOVE EXISTING SUSPENDED LAY-IN PANEL CEILING SYSTEM IN ITS ENTIRETYINCLUDING, BUT NOT LIMITED TO THE CEILING PADS, GRID, SUSPENSION WIRES,AND ALL RELATED ANCHORS. PATCH AND REPAIR EXISTING SURFACES TO REMAINAND PREP FOR NEW CONSTRUCTION/FINISH.05REMOVE EXISTING DOOR SYSTEM IN ITS ENTIRETY INCLUDING, BUT NOT LIMITEDTO THE DOOR, FRAME, SIDELIGHTS, GLAZING, HARDWARE AND ALL RELATEDANCHORS. SALVAGE FOR RELOCATION; REF A-SERIES DWGS FOR NEW LOCATION.PREP EXISTING OPENING FOR NEW CONSTRUCTION. PATCH AND REPAIR ALLADJACENT SURFACES TO REMAIN FOR NEW CONSTRUCTION/FINISH.06REMOVE EXISTING DOOR AND ALL RELATED HARDWARE. PROTECT EXISTINGDOOR FRAME TO REMAIN. PREP EXISTING DOOR FRAME FOR NEW CONSTRUCTION.07REMOVE EXISTING WINDOW SYSTEM IN ITS ENTIRETY INCLUDING, BUT NOT LIMITEDTO THE GLAZING, SPANDREL PANELS, WINDOW FRAME, SEALANTS, AND ALLRELATED ANCHORS. PATCH AND REPAIR ADJACENT SURFACES TO REMAIN ANDPREP FOR NEW CONSTRUCTION/FINISH.DEMOLITION FLOOR PLAN NOTES#NOTE08REMOVE EXISTING CASEWORK IN ITS ENTIRETY INCLUDING, BUT NOT LIMITED TOWALL CABINETS, BASE CABINETS, AND ASSOCIATED COUNTERTOP. SALVAGE ANDPLACE IN OWNER DESIGNATED STORAGE AREA. PATCH AND REPAIR EXISTINGADJACENT SURFACES TO REMAIN AND PREP FOR NEW CONSTRUCTION.09REMOVE EXISTING CASEWORK IN ITS ENTIRETY INCLUDING, BUT NOT LIMITED TOBASE CABINETS, COUNTERTOPS, FILL PANELS, AND ALL RELATED ANCHORS.PATCH AND REPAIR EXISTING ADJACENT SURFACES TO REMAIN AND PREP FORNEW CONSTRUCTION.10EXISTING LAMINATE FLOORING TO REMAIN, PROTECT DURING CONSTRUCTION11REMOVE EXISTING INTERIOR WALL CONSTRUCTION IN ITS ENTIRETY BELOWWINDOW FRAME. FIELD VERIFY ALL EXISTING WALL CONSTRUCTION PRIOR TODEMOLITION.12REMOVE EXISTING LIBRARY SHELVING IN ITS ENTIRELY AND SALVAGE FOR REUSEAND RELOCATION.13REMOVE EXISTING CARPET FLOOR FINISH IN ITS ENTIRETY TO LIMITS INDICATEDINCLUDING, BUT NOT LIMITED TO THE CARPET, ADHESIVES/TACK STRIPS,TRANSITION STRIPS AND ALL ASSOCIATED WALL BASE. CARPET ONLY ON GROUNDLEVEL IS TO BE DEMOLISHED. EXISTING CARPET ON RISERS SHALL BE EXISTING TOREMAIN.15REMOVE INTERIOR WALL AS REQUIRED FOR PLUMBING WORK. PATCH AND REPAIREXISTING SURFACES TO REMAIN. CREATE A SMOOTH AND SEAMLESS TRANSITION.MATCH EXISTING FINISH TYPE AND COLOR, V.I.F.16BASE BID: APPLY DEMOLITION NOTES 01, 03, 08, 09 SIMILAR TO ADJACENT OFFICES.ROOM B137 ALTERNATE: EXISTING CONSTRUCTION TO REMAIN.17BASE BID: EXISTING WALLS AND FRAMES TO REMAIN. ROOM B137 ALTERNATE:APPLY DEMOLITION NOTES AS SHOWN.18REMOVE EXISTING FIRE PANEL INCLUDING BUT NOT LIMITED TO ALL RELATEDANCHORS, COVERS, AND CONDUIT. SALVAGE FOR RELOCATION. REF FLOOR PLANSFOR NEW PANEL LOCATION.19REMOVE EXISTING WALLCOVERING IN ITS ENTIRETY INCLUDING ADHESIVES.PATCH AND REPAIR ALL EXISTING SURFACES TO REMAIN. PREP EXISTINGSURFACES FOR NEW CONSTRUCTION/FINISH.20REMOVE EXISTING PROJECTOR BOX INCLUDING BUT NOT LIMITED TO ALLHANGERS, ATTACHMENTS, AND ACCESSORIES. PREP REMAINING SURFACES FORNEW CONSTRUCTION.21EXISTING CEILING GRID TO REMAIN. REPLACE TILES WITH ACP-122REMOVE EXISTING INTERIOR WALL CONSTRUCTION IN ITS ENTIRETY TO LIMITSINDICATED INCLUDING, BUT NOT LIMITED TO DOORS, FRAMES, WINDOWS AND ALLMISCELLANEOUS FRAMING. FIELD VERIFY ALL EXISTING WALL CONSTRUCTIONPRIOR TO DEMOLITION. REFER TO ARCHITECTURAL AND INTERIOR FLOOR PLANSFOR FINISH CONDITIONS AND DIMENSIONS. PATCH AND REPAIR EXISTINGADJACENT SURFACES TO REMAIN AND PREP FOR NEW CONSTRUCITON. SALVAGEOAK WALL CAPS AND PLACE IN OWNER DESIGNATED STORAGE AREA.24REMOVE DAMAGED GWB FROM WALL INCLUDING BUT NOT LIMITED TO ANYRELATED FASTENERS, ADHESIVES, ETC. PREP REMAINING SURFACES FOR NEWCONSTRUCTION. VERIFY EXTENT AND LOCATIONS IN FIELD25REMOVE EXISTING TOILETS, SINKS, URINALS AND ALL RELATED ACCESSORIES INTHEIR ENTIRETY INCLUDING, BUT NOT LIMITED TO TOILET PAPER DISPENSERS,GRAB BARS, MIRRORS AND SOAP DISPENSERS. PATCH AND REPAIR ALL EXISTINGSURFACES TO REMAIN. PREP FOR NEW CONSTRUCTION/FINISH. SEE P-SERIESDRAWINGS FOR PLUMBING SCOPE.#RevisionDate DN5A21BCDGA5A4A3A2A1E.P02020202020202020710100909090808080505050505010101010909090908080808010101010109080105010908090809080101222222220101010505080108080901010101090809090808222222222222222222222222070808080808080808080808080808080808070101050401090808090909090909090909090909090909091112130101090303030321030316030303030303030303170501ALT.0501ALT.0501ALT.170304ALT.04ALT.04040418190120222222020908080803ROOM B137 ALTERNATE04ALT.04ALT.040404040404040404040404A. Contractor shall field-verify all existing conditions, dimensions, and arrangements.B. Contractor is responsible for protection of all existing surfaces, materials, and components to remain or be relocated. Damage to these resulting from performance of Work shall be repaired by Contractor to satisfaction of Owner and Architect at no additional expense to Owner.C. Contractor shall provide temporary dust protection as required to prevent construction debris and dust from migrating out of Project Area. Owner/Architect shall confirm all dust prevention measures/locations and shall determine changes to these measures.D. All existing equipment and fixtures shall remain property of Owner. All reusable items salvaged during demolition operations shall be retained for Owner's inspection. Only items so inspected and rejected by Owner shall be disposed. All other such items shall be turned over to Owner for disposition.E. All existing surfaces located adjacent to, or exposed by demolition work and scheduled to receive new construction shall be patched and repaired as required to cleanly receive new work.F. All existing surfaces located adjacent to, or exposed by demolition work and scheduled to remain exposed after completion of new const. shall be repaired and patched as required to receive new finishes.G. Owner will be responsible for removal/rearrangement of all existing loose furnishings during construction, unless noted otherwise.H. Refer to Mech./Elec. Drawings for additional patching and preparation work related to M.E.P. demolition items.I. Existing sleeves, holes, and other penetrations or new damage of existing building structure above grade exposed by demolition and removal of piping, appurtenances, equipment shall be patched and repaired as part of the Work. Maintain fire ratings of all and adjacent construction affected.J. Cap all piping to remain or abandoned in accordance with requirements of authority having jurisdiction and in accordance with all local and state plumbing and health codes. Utilize only pre-manufactured and approved fittings to cap existing piping.K. Each Contractor is responsible for all demolition work required or noted for installation of new Work. Demolition may include associated distribution systems, appurtenances, equipment supporting controls, and miscellaneous supports, unless noted otherwise.L. Coordinate all demolition with Project sequencing as directed by General Contractor or Construction Manager.General Demolition NotesN123456ABCDE123456ABCDEProject No.Project DateProducedThese Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect.KEY PLANBA5/22/2023 2:32:08 PMC:\_RevitLocal\2023-067.POR_Bldg001_A_2023\2023-067.POR_Bldg001_A_2023_mmiller.rvt2023-067.POR05.22.2023DEMOLITION FLOORPLAN -UNIT BAD1B1MWCoram DeoAcademyPhase OneRenovations2023-067.POR_Coram Deo Academy_Phase One Renovations_525 Congressional Blvd,Carmel, IN 46032AD1B1_ DEMOLITION FLOOR PLAN -UNIT B1/8" = 1'-0"1ADEMOLITION FLOOR PLAN -UNIT BDEMOLITION FLOOR PLAN NOTES#NOTE01REMOVE EXISTING INTERIOR WALL CONSTRUCTION IN ITS ENTIRETY TO LIMITSINDICATED INCLUDING, BUT NOT LIMITED TO DOORS, FRAMES, WINDOWS AND ALLMISCELLANEOUS FRAMING. FIELD VERIFY ALL EXISTING WALL CONSTRUCTIONPRIOR TO DEMOLITION. REFER TO ARCHITECTURAL AND INTERIOR FLOOR PLANSFOR FINISH CONDITIONS AND DIMENSIONS. PATCH AND REPAIR EXISTINGADJACENT SURFACES TO REMAIN AND PREP FOR NEW CONSTRUCITON.02BASE BID: EXISTING CARPET TILE TO REMAIN. SCIENCE LAB ALTERNATE: REMOVEEXISTING CARPET FLOOR FINISH IN ITS ENTIRETY TO LIMITS INDICATED INCLUDING,BUT NOT LIMITED TO THE CARPET, ADHESIVES/TACK STRIPS, TRANSITION STRIPSAND ALL ASSOCIATED WALL BASE. SALVAGE CARPET TILES FOR PATCHINGFLOORING IN OTHER LOCATIONS. PATCH AND REPAIR EXISTING SURFACES TOREMAIN AND PREP FOR NEW CONSTRUCTION/FINISH.02REMOVE EXISTING CARPET FLOOR FINISH IN ITS ENTIRETY TO LIMITS INDICATEDINCLUDING, BUT NOT LIMITED TO THE CARPET, ADHESIVES/TACK STRIPS,TRANSITION STRIPS AND ALL ASSOCIATED WALL BASE. SALVAGE CARPET TILESFOR PATCHING FLOORING IN OTHER LOCATIONS. PATCH AND REPAIR EXISTINGSURFACES TO REMAIN AND PREP FOR NEW CONSTRUCTION/FINISH.03EXISTING SUSPENDED ACOUSTICAL CEILING SYSTEM TO REMAIN. PROTECTCEILING SYSTEM AND MODIFY CEILING SYSTEM AS REQUIRED FOR NEWCONSTRUCTION.04REMOVE EXISTING SUSPENDED LAY-IN PANEL CEILING SYSTEM IN ITS ENTIRETYINCLUDING, BUT NOT LIMITED TO THE CEILING PADS, GRID, SUSPENSION WIRES,AND ALL RELATED ANCHORS. PATCH AND REPAIR EXISTING SURFACES TO REMAINAND PREP FOR NEW CONSTRUCTION/FINISH.05REMOVE EXISTING DOOR SYSTEM IN ITS ENTIRETY INCLUDING, BUT NOT LIMITEDTO THE DOOR, FRAME, SIDELIGHTS, GLAZING, HARDWARE AND ALL RELATEDANCHORS. SALVAGE FOR RELOCATION; REF A-SERIES DWGS FOR NEW LOCATION.PREP EXISTING OPENING FOR NEW CONSTRUCTION. PATCH AND REPAIR ALLADJACENT SURFACES TO REMAIN FOR NEW CONSTRUCTION/FINISH.06REMOVE EXISTING DOOR AND ALL RELATED HARDWARE. PROTECT EXISTINGDOOR FRAME TO REMAIN. PREP EXISTING DOOR FRAME FOR NEW CONSTRUCTION.07REMOVE EXISTING WINDOW SYSTEM IN ITS ENTIRETY INCLUDING, BUT NOT LIMITEDTO THE GLAZING, SPANDREL PANELS, WINDOW FRAME, SEALANTS, AND ALLRELATED ANCHORS. PATCH AND REPAIR ADJACENT SURFACES TO REMAIN ANDPREP FOR NEW CONSTRUCTION/FINISH.DEMOLITION FLOOR PLAN NOTES#NOTE08REMOVE EXISTING CASEWORK IN ITS ENTIRETY INCLUDING, BUT NOT LIMITED TOWALL CABINETS, BASE CABINETS, AND ASSOCIATED COUNTERTOP. SALVAGE ANDPLACE IN OWNER DESIGNATED STORAGE AREA. PATCH AND REPAIR EXISTINGADJACENT SURFACES TO REMAIN AND PREP FOR NEW CONSTRUCTION.09REMOVE EXISTING CASEWORK IN ITS ENTIRETY INCLUDING, BUT NOT LIMITED TOBASE CABINETS, COUNTERTOPS, FILL PANELS, AND ALL RELATED ANCHORS.PATCH AND REPAIR EXISTING ADJACENT SURFACES TO REMAIN AND PREP FORNEW CONSTRUCTION.10EXISTING LAMINATE FLOORING TO REMAIN, PROTECT DURING CONSTRUCTION11REMOVE EXISTING INTERIOR WALL CONSTRUCTION IN ITS ENTIRETY BELOWWINDOW FRAME. FIELD VERIFY ALL EXISTING WALL CONSTRUCTION PRIOR TODEMOLITION.12REMOVE EXISTING LIBRARY SHELVING IN ITS ENTIRELY AND SALVAGE FOR REUSEAND RELOCATION.13REMOVE EXISTING CARPET FLOOR FINISH IN ITS ENTIRETY TO LIMITS INDICATEDINCLUDING, BUT NOT LIMITED TO THE CARPET, ADHESIVES/TACK STRIPS,TRANSITION STRIPS AND ALL ASSOCIATED WALL BASE. CARPET ONLY ON GROUNDLEVEL IS TO BE DEMOLISHED. EXISTING CARPET ON RISERS SHALL BE EXISTING TOREMAIN.15REMOVE INTERIOR WALL AS REQUIRED FOR PLUMBING WORK. PATCH AND REPAIREXISTING SURFACES TO REMAIN. CREATE A SMOOTH AND SEAMLESS TRANSITION.MATCH EXISTING FINISH TYPE AND COLOR, V.I.F.16BASE BID: APPLY DEMOLITION NOTES 01, 03, 08, 09 SIMILAR TO ADJACENT OFFICES.ROOM B137 ALTERNATE: EXISTING CONSTRUCTION TO REMAIN.17BASE BID: EXISTING WALLS AND FRAMES TO REMAIN. ROOM B137 ALTERNATE:APPLY DEMOLITION NOTES AS SHOWN.18REMOVE EXISTING FIRE PANEL INCLUDING BUT NOT LIMITED TO ALL RELATEDANCHORS, COVERS, AND CONDUIT. SALVAGE FOR RELOCATION. REF FLOOR PLANSFOR NEW PANEL LOCATION.19REMOVE EXISTING WALLCOVERING IN ITS ENTIRETY INCLUDING ADHESIVES.PATCH AND REPAIR ALL EXISTING SURFACES TO REMAIN. PREP EXISTINGSURFACES FOR NEW CONSTRUCTION/FINISH.20REMOVE EXISTING PROJECTOR BOX INCLUDING BUT NOT LIMITED TO ALLHANGERS, ATTACHMENTS, AND ACCESSORIES. PREP REMAINING SURFACES FORNEW CONSTRUCTION.21EXISTING CEILING GRID TO REMAIN. REPLACE TILES WITH ACP-122REMOVE EXISTING INTERIOR WALL CONSTRUCTION IN ITS ENTIRETY TO LIMITSINDICATED INCLUDING, BUT NOT LIMITED TO DOORS, FRAMES, WINDOWS AND ALLMISCELLANEOUS FRAMING. FIELD VERIFY ALL EXISTING WALL CONSTRUCTIONPRIOR TO DEMOLITION. REFER TO ARCHITECTURAL AND INTERIOR FLOOR PLANSFOR FINISH CONDITIONS AND DIMENSIONS. PATCH AND REPAIR EXISTINGADJACENT SURFACES TO REMAIN AND PREP FOR NEW CONSTRUCITON. SALVAGEOAK WALL CAPS AND PLACE IN OWNER DESIGNATED STORAGE AREA.24REMOVE DAMAGED GWB FROM WALL INCLUDING BUT NOT LIMITED TO ANYRELATED FASTENERS, ADHESIVES, ETC. PREP REMAINING SURFACES FOR NEWCONSTRUCTION. VERIFY EXTENT AND LOCATIONS IN FIELD25REMOVE EXISTING TOILETS, SINKS, URINALS AND ALL RELATED ACCESSORIES INTHEIR ENTIRETY INCLUDING, BUT NOT LIMITED TO TOILET PAPER DISPENSERS,GRAB BARS, MIRRORS AND SOAP DISPENSERS. PATCH AND REPAIR ALL EXISTINGSURFACES TO REMAIN. PREP FOR NEW CONSTRUCTION/FINISH. SEE P-SERIESDRAWINGS FOR PLUMBING SCOPE.#RevisionDate MHMDDCRHMMARARARARTTTTTTDNOVERALL PLANS ARE FOR REFERENCE ONLY; REFERENCE UNIT PLANS FOR FULL SCOPE OF WORKSHADED REGION INDICATES AREAS WITH NO SCOPE OF WORKCLASSROOMB115CHAPELB111CAFETERIAB111ACOMMONSB141CLASSROOMB145STORAGEB146ASTORAGEB146CLASSROOMB127LIBRARYB135IDFB129CLASSROOMB137PRE-KB132KITCHENETTEB133CLASSROOMB130CORRIDORB001CLASSROOMB126CLASSROOMB121CLASSROOMA116CLASSROOMA120OFFICEA119SCIENCE LABA121BREAK ROOMA106GYMA110STORAGEA110ARRA110CROOM B137 ALTERNATESCIENCE LAB ALTERNATEGYMNASIUM WALL ALTERNATEMUSIC DOOR ALTERNATEN123456ABCDE123456ABCDEProject No.Project DateProducedThese Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect.KEY PLANBA5/22/2023 2:32:32 PMC:\_RevitLocal\2023-067.POR_Bldg001_A_2023\2023-067.POR_Bldg001_A_2023_mmiller.rvt2023-067.POR05.22.2023OVERALL FIRST FLOORPLANAF101MWCoram DeoAcademyPhase OneRenovations2023-067.POR_Coram Deo Academy_Phase One Renovations_525 Congressional Blvd,Carmel, IN 46032AF101_ OVERALL FIRST FLOOR PLAN1/16" = 1'-0"1BOVERALL FLOOR PLAN#RevisionDate 678549A21BCDEE101112HJKLFGA5E.PS4-CA110.1F ETRHM1 : HM-001 2=F1A110.2F ETRHM1 : HM-001 2=F1A110.3G ETRSF-125A Exist : SF-125A=EXISTGYMA110CLASSROOMB117CLASSROOMB115RRA110CCORRIDORA002STORAGEA110ACLASSROOMA116CLASSROOMA120SCIENCE LABA121CLASSROOMA118OFFICEA1195DAF1A10104CAFETERIAB111A08CLASSROOMB120CLASSROOMB110CLASSROOMA113STORAGEB112STORAGEA112STORAGEA111STORAGEA117BREAK ROOMA106PRACTICE ROOMB117APRACTICE ROOMB116PRACTICE ROOMB114PRACTICE ROOMB113WOMENS RRB104WOMENS RRA108MENS RRA109MENS RRB103ELECTRICALA112AUNOCCUPIEDA130UNOCCUPIEDA129UNOCCUPIEDA128UNOCCUPIEDA127UNOCCUPIEDA126UNOCCUPIEDA125UNOCCUPIEDA124UNOCCUPIEDA123UNOCCUPIEDA122STORAGEA106ASTORAGEB102STORAGEA103AJANITORA107RISER RMA108AOFFICEA102OFFICEA103OFFICEA104OFFICEB105OFFICEB106OFFICEB107OFFICEB108OFFICEB115ASTORAGEB115BSTORAGEB115COFFICEA105VESTIBULEA110BVESTIBULEA100ACORRIDORA003CORRIDORA001VESTIBULEA003ACLINICA101PARENT ROOMB100COPIERB109LOBBYA100VESTIBULEA003BSTORAGEB101OFFICEA115OFFICEA114PRACTICE ROOMB114LOBBYA100091111121314141511EQ.EQ.06A110.4F ETRHM1 : HM-001 2=F11712" MIN CLR.MB10I-2012E2CI-2012A2D2B231AA-600NRIU2416SCIENCE LAB ALT.051313ALT.262728245C5BI-2015AA. Comply with all applicable codes and regulations pertaiting to this scope of work.B. All products to be handled, stored, and installed per manufacturer requirements.C. All dimensions shown are to face of stud or masonry, unless noted otherwise. Dimensions designated as "CLR or "clear" indicate a clear dimension from face of finish to face of finish. Dimensions of exterior walls are to outside edge of foundation.D. All openings for Mechanical, Plumbing, Fire Protection and Electrical shall be fire stopped at each floor penetration.E. Dimensional Lumber shall be Construction or No 2 Grade. Any concealed lumber in contact with concrete or masonry shall be preservative treated according to AWPA C2. F. Provide bracing and blocking as required in walls supporting casework, tackboards, markerboards, and restroom accessories. Blocking shall be solid wood minimum 3/4" x 6" wide.G. All door frames are located 4" from adjacent wall, unless noted otherwise.H. All exposed outside corners of CMU shall be bullnosed.I. Seal all joints between dissimilar materials with nonstaining sealant apropriate for both materials and application. J. All gypsum wallboard is 5/8" Type "X", unless noted otherwise.K. Where new floors meet existing floors, a smooth, straight, and flush transition shall be constructed. Verify in field existing floor elevations and conditions where a new floor shall be constructed adjacent. Trim and patch existing floor as required to achieve desired transition.L. All interior walls are Type "S4-C", unless noted otherwise.M. Refer to C Series drawings for base elevation height (0'-0") relative to USGS (United States Geological Survey data).N. Hatching within walls shown in plans and sections indicates new construction.M. Loose furniture is not provided in this contract. General Plan NotesLevel 10' -0"Level 10' -0"Level 10' -0"Level 10' -0"EAF1A14D4' - 0"05 40 00 -EXT. STEEL STUDFRAMING, 16 GA, @ 16" O.C.REINFORCED WITH MIDWALL600MW-48 EVERY OTHER STUD5/8 PLYWOOD SHEATHINGEXISTING ALUMINUM STOREFRONT SYSTEM. PROTECT DURING CONSTRUCTION2IN THICK GYMNASIUM WALL PADS SECURED TO WALL WITH Z CLIP ATTACHMENT SYSTEM. BASIS OF DESIGN "ECOVISION WALL PAD" BY DRAPER INC. 06 10 53.B2 -WOOD BLOCKING, 2XCONTINUOUS1/2" PLYWOOD ATTACHED TO METALSTUDS. PAINT BLACK, COLORSELECTED BY ARCHITECT.CLR.2" MIN.05 40 00.C23 -EXT. STEEL STUDFRAMING, 16-GAGE, 6" @ 16" O.C.WRAP TOP EDGE WITH GYMNASIUM WALL PADDINGN123456ABCDE123456ABCDEProject No.Project DateProducedThese Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect.KEY PLANBA5/22/2023 2:33:04 PMC:\_RevitLocal\2023-067.POR_Bldg001_A_2023\2023-067.POR_Bldg001_A_2023_mmiller.rvt2023-067.POR05.22.2023FIRST FLOOR PLAN -UNITAAF1A1MWCoram DeoAcademyPhase OneRenovations2023-067.POR_Coram Deo Academy_Phase One Renovations_525 Congressional Blvd,Carmel, IN 46032AF1A1_ FIRST FLOOR PLAN -UNIT A1/8" = 1'-0"1AFLOOR PLAN -UNIT AFLOOR PLAN NOTES#Note01ALIGN FACE OF NEW WALL/INFILL WITH ADJACENT WALL FACE.02INFILL OPENING WITH WALL TO MATCH SURROUNDING/ADJACENT WALLCONSTRUCTION. VERIFY EXISTING WALL CONDITIONS/CONSTRUCTION ANDDIMENSIONS IN THE FIELD. ALIGN THE FACE OF THE NEW INFILL WALL WITHTHE ADJACENT EXISTING WALL FACE.03INTERIOR WOODFRAMED WINDOW WITH GLAZING. REF A-600 FOR SIZE ANDDETAILS04RELOCATED EXISTING DOOR AND FRAME, REF A-600 SERIES FOR SIZE ANDTYPE.05BASE BID: EXISTING FLOORING TO REMAIN; PATCH AREAS AFFECTED BYDEMOLITION WITH SALVAGED OR NEW TO MATCH EXISTING CARPET TILE.SCIENCE LAB ALTERNATE: SCIENCE LAB EQUIPMENT, CASEWORK ANDRESILIENT SHEET FLOORING AS SHOWN.06NEW DOOR IN EXISTING FRAME WITH NEW CONTINUOUS ALUMINUM HINGE. REFDOOR SCHEDULE FOR SIZE. VERIFY IN FIELD.07REATTACH EXISTING RAILING TO EXISTING CONCRETE STAIR; REF DETAILS08GYMNASIUM WALL PADS, 2' L X 4' H. WRAP ALL OUTSIDE CORNERS AND EDGESTO CREATE A CONTINUOUS RUN.09RUBBER TILE USED FOR INFILL POST DEMOLITION ARE TO MATCH EXISTING.10FOLLOWING DEMOLITION, FLOORING ON GROUND IS TO BE VINYLCOMPOSITION TILE, VCT. VCT IS TO ABUTT TO EXISTING VCT AND IS TO MATCHEXISTING.11AREAS AFFECTED BY DEMOLITION ARE TO RECEIVE CARPET TILE. CARPETTILES ARE TO MATCH EXISTING12EYEWASH STATION; REF P-SERIES DWGS.3/4" = 1'-0"5DALTERNATE -WALL SECTION @ GYM WINDOWS1 1/2" = 1'-0"4DSECTION DETAIL -WALL CAPFLOOR PLAN NOTES#Note13BASE BID: GYMNASIUM WALL PADS BELOW SILL. GYMNASIUM WALL ALTERNATE:NEW WALL CONSTRUCTION IN FRONT OF EXISTING WINDOWS; REF SECTIONDETAILS.14WRAP CORNER WITH GYMNASIUM WALL PADS; TERMINATE AT FACE OFEXISTING STOREFRONT.15NEW UTILITY SINK- REF P-DWGS16BASE BID: EXISTING DOOR AND FRAME TO REMAIN. MUSIC DOOR ALTERNATE:RELOCATED DOOR AND NEW WALL CONSTRUCTION AS SHOWN. REF DOORSCHEDULE FOR SIZE AND TYPE17BASE BID: EXISTING DOOR TO REMAIN. SCIENCE LAB ALTERNATE: REMOVEEXISTING DOOR AND APPLY PLAN NOTE 2.18FOLLOWING DEMOLITION, FLOORING ON GROUND IS TO BE CARPET TILE, CPT-1(MATCH EXISTING). EXISTING VCT IS TO BE DEMOLISHED OR COVERED WITHCPT-1.19EXISTING FLOORING FINISH ON RISERS AND FABRIC-WRAPPED WALL PANELSARE TO BE EXISTING TO REMAIN.20WALL TO RECEIVE PAINT, P-2, INSIDE CORNER TO INSIDE CORNER.21BASE BID: 4 OFFICES COMBINED INTO 1 SPACE, REF DEMOLITION PLANS. ROOMB137 ALTERNATE: NEW WALL CONSTRUCTION AS SHOWN.22RELOCATED FIRE PANEL. COORDINATE FINAL LOCATION WITH OWNER IN FIELD.23SCIENCE LAB ALTERNATE: NEW DRYWALL ON EXISTING STUD TO DECK, BOTHSIDES OF THE WALL. REF WALL SECTIONS AND DETAILS.24PATCH AND REPAIR EXISTING GWB TO CREATE A SEAMLESS, SMOOTHTRANSITION. PREP FOR FINISH25NEW FLOORING (LVT) TO ALIGN WITH NEW BULKHEADS.26MECHANICAL HOOD. BASIS OF DESIGN ELIMINATOR 500 SERIES ADA DESIGN.PART # EH-511-72.INCLUDE (1) CORROSIVE AND (1) FLAMMABLE BASE CABINETBELOW. REF M-SERIES DWGS27NEW DOOR CLOSER ON EXISTING DOOR. BASIS OF DESIGN LCN 1250 SERIES.28NEW STAINLESS STEEL KICK PLATE MOUNED TO FACE OF ALUMINUM EXTERIORDOOR. EXTEND MIN 1" BEYOND EDGE OF GLASS IN DOOR AND TO BOTTOM OFEXIT DEVICE. ATTACH WITH COMPATIBLE METAL SCREWS INSTALLED IN FOAMGASKET; COUNTERINK ALL HOLES IN EXISTING DOOR. SEPARATE DISSIMILARMETALS WITH NON CORROSIVE MATERIALS. FIELD VERIFY.#RevisionDateSHADED REGIONS ARE NO SCOPE ROOMS; ALL EXISTING TO REMAIN. DN5A21BCDGA5A4A3A2A1E.PPRE-KB132OFFICEB131CLASSROOMB130CLASSROOMB126CLASSROOMB121CLASSROOMB127LIBRARYB135COMMONSB141CLASSROOMB145CLASSROOMB138CLASSROOMB137CHAPELB111020303010101S4iCB130F ETRHM-112A Exist : HM-112D (9'-2")=F2B126F ETRHM-112A Exist : HM-112D (9'-2")=F2CAFETERIAB111A07CHAPELB111CLASSROOMB120CLASSROOMB110STORAGEB112PRACTICE ROOMB113OFFICEB107OFFICEB108OFFICEB115AKITCHENETTEB122VESTIBULEB111BCORRIDORB001PARENT ROOMB100COPIERB109CLASSROOMB136CLASSROOMB118CLASSROOMB119STORAGEB146AWOMENS RRB148MENS RRB149RRB134PLUMBINGB123IDFB129STORAGEB139STORAGEB140STORAGEB142STORAGEB143STORAGEB144STORAGEB129ASTORAGEB129BOFFICEB147OFFICEB119AOFFICEB124KITCHENB128KITCHENETTEB133STORAGEB14603F-4F-3F-301S4-CS4iCS4iCS4iC1011111111116' - 0"3' - 0"6' - 0"1' - 4"F-410' - 6" CLR.S4iC5' - 4"5' - 4"12" MIN. CLR.OFFICEB137A0101S4iCS4iCB137F ETRHM-112A Exist : HM-112D (9'-2")=F221222' - 0"2' - 0"ROOM B137 ALTERNATEA. Comply with all applicable codes and regulations pertaiting to this scope of work.B. All products to be handled, stored, and installed per manufacturer requirements.C. All dimensions shown are to face of stud or masonry, unless noted otherwise. Dimensions designated as "CLR or "clear" indicate a clear dimension from face of finish to face of finish. Dimensions of exterior walls are to outside edge of foundation.D. All openings for Mechanical, Plumbing, Fire Protection and Electrical shall be fire stopped at each floor penetration.E. Dimensional Lumber shall be Construction or No 2 Grade. Any concealed lumber in contact with concrete or masonry shall be preservative treated according to AWPA C2. F. Provide bracing and blocking as required in walls supporting casework, tackboards, markerboards, and restroom accessories. Blocking shall be solid wood minimum 3/4" x 6" wide.G. All door frames are located 4" from adjacent wall, unless noted otherwise.H. All exposed outside corners of CMU shall be bullnosed.I. Seal all joints between dissimilar materials with nonstaining sealant apropriate for both materials and application. J. All gypsum wallboard is 5/8" Type "X", unless noted otherwise.K. Where new floors meet existing floors, a smooth, straight, and flush transition shall be constructed. Verify in field existing floor elevations and conditions where a new floor shall be constructed adjacent. Trim and patch existing floor as required to achieve desired transition.L. All interior walls are Type "S4-C", unless noted otherwise.M. Refer to C Series drawings for base elevation height (0'-0") relative to USGS (United States Geological Survey data).N. Hatching within walls shown in plans and sections indicates new construction.M. Loose furniture is not provided in this contract. General Plan NotesN123456ABCDE123456ABCDEProject No.Project DateProducedThese Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect.KEY PLANBA5/22/2023 2:33:21 PMC:\_RevitLocal\2023-067.POR_Bldg001_A_2023\2023-067.POR_Bldg001_A_2023_mmiller.rvt2023-067.POR05.22.2023FIRST FLOOR PLAN -UNITBAF1B1MWCoram DeoAcademyPhase OneRenovations2023-067.POR_Coram Deo Academy_Phase One Renovations_525 Congressional Blvd,Carmel, IN 46032AF1B1_ FIRST FLOOR PLAN -UNIT B1/8" = 1'-0"1AFLOOR PLAN -UNIT BFLOOR PLAN NOTES#Note01ALIGN FACE OF NEW WALL/INFILL WITH ADJACENT WALL FACE.02INFILL OPENING WITH WALL TO MATCH SURROUNDING/ADJACENT WALLCONSTRUCTION. VERIFY EXISTING WALL CONDITIONS/CONSTRUCTION ANDDIMENSIONS IN THE FIELD. ALIGN THE FACE OF THE NEW INFILL WALL WITHTHE ADJACENT EXISTING WALL FACE.03INTERIOR WOODFRAMED WINDOW WITH GLAZING. REF A-600 FOR SIZE ANDDETAILS04RELOCATED EXISTING DOOR AND FRAME, REF A-600 SERIES FOR SIZE ANDTYPE.05BASE BID: EXISTING FLOORING TO REMAIN; PATCH AREAS AFFECTED BYDEMOLITION WITH SALVAGED OR NEW TO MATCH EXISTING CARPET TILE.SCIENCE LAB ALTERNATE: SCIENCE LAB EQUIPMENT, CASEWORK ANDRESILIENT SHEET FLOORING AS SHOWN.06NEW DOOR IN EXISTING FRAME WITH NEW CONTINUOUS ALUMINUM HINGE. REFDOOR SCHEDULE FOR SIZE. VERIFY IN FIELD.07REATTACH EXISTING RAILING TO EXISTING CONCRETE STAIR; REF DETAILS08GYMNASIUM WALL PADS, 2' L X 4' H. WRAP ALL OUTSIDE CORNERS AND EDGESTO CREATE A CONTINUOUS RUN.09RUBBER TILE USED FOR INFILL POST DEMOLITION ARE TO MATCH EXISTING.10FOLLOWING DEMOLITION, FLOORING ON GROUND IS TO BE VINYLCOMPOSITION TILE, VCT. VCT IS TO ABUTT TO EXISTING VCT AND IS TO MATCHEXISTING.11AREAS AFFECTED BY DEMOLITION ARE TO RECEIVE CARPET TILE. CARPETTILES ARE TO MATCH EXISTING12EYEWASH STATION; REF P-SERIES DWGS.13BASE BID: GYMNASIUM WALL PADS BELOW SILL. GYMNASIUM WALL ALTERNATE:NEW WALL CONSTRUCTION IN FRONT OF EXISTING WINDOWS; REF SECTIONDETAILS.14WRAP CORNER WITH GYMNASIUM WALL PADS; TERMINATE AT FACE OFEXISTING STOREFRONT.15NEW UTILITY SINK- REF P-DWGS16BASE BID: EXISTING DOOR AND FRAME TO REMAIN. MUSIC DOOR ALTERNATE:RELOCATED DOOR AND NEW WALL CONSTRUCTION AS SHOWN. REF DOORSCHEDULE FOR SIZE AND TYPE17BASE BID: EXISTING DOOR TO REMAIN. SCIENCE LAB ALTERNATE: REMOVEEXISTING DOOR AND APPLY PLAN NOTE 2.18FOLLOWING DEMOLITION, FLOORING ON GROUND IS TO BE CARPET TILE, CPT-1(MATCH EXISTING). EXISTING VCT IS TO BE DEMOLISHED OR COVERED WITHCPT-1.19EXISTING FLOORING FINISH ON RISERS AND FABRIC-WRAPPED WALL PANELSARE TO BE EXISTING TO REMAIN.20WALL TO RECEIVE PAINT, P-2, INSIDE CORNER TO INSIDE CORNER.21BASE BID: 4 OFFICES COMBINED INTO 1 SPACE, REF DEMOLITION PLANS. ROOMB137 ALTERNATE: NEW WALL CONSTRUCTION AS SHOWN.22RELOCATED FIRE PANEL. COORDINATE FINAL LOCATION WITH OWNER IN FIELD.23SCIENCE LAB ALTERNATE: NEW DRYWALL ON EXISTING STUD TO DECK, BOTHSIDES OF THE WALL. REF WALL SECTIONS AND DETAILS.24PATCH AND REPAIR EXISTING GWB TO CREATE A SEAMLESS, SMOOTHTRANSITION. PREP FOR FINISH25NEW FLOORING (LVT) TO ALIGN WITH NEW BULKHEADS.26MECHANICAL HOOD. BASIS OF DESIGN ELIMINATOR 500 SERIES ADA DESIGN.PART # EH-511-72.INCLUDE (1) CORROSIVE AND (1) FLAMMABLE BASE CABINETBELOW. REF M-SERIES DWGS27NEW DOOR CLOSER ON EXISTING DOOR. BASIS OF DESIGN LCN 1250 SERIES.28NEW STAINLESS STEEL KICK PLATE MOUNED TO FACE OF ALUMINUM EXTERIORDOOR. EXTEND MIN 1" BEYOND EDGE OF GLASS IN DOOR AND TO BOTTOM OFEXIT DEVICE. ATTACH WITH COMPATIBLE METAL SCREWS INSTALLED IN FOAMGASKET; COUNTERINK ALL HOLES IN EXISTING DOOR. SEPARATE DISSIMILARMETALS WITH NON CORROSIVE MATERIALS. FIELD VERIFY.#RevisionDateSHADED REGIONS ARE NO SCOPE ROOMS; ALL EXISTING TO REMAIN. VHHVTVHVVVSDSDSDA. All ceilings are at 10'-0" AFF, unless noted otherwise.B. All bulkheads are at 9'-10" AFF, unless noted otherwise.C. All grids are centered in rooms, unless noted otherwise.D. All exposed ductwork, piping etc. shall be painted. Color selected by Architect.E. Locate sprinkler heads in center of ceiling panel -where applicable.F. Bulkheads to receive paint, P-1, in its entirety unless otherwise noted. General Refl. Ceiling Plan Notes667788554499AA2211BBCCDDEE101011111212HHJJKKLLFFGGA5A5E.PE.P678549A21BCDE101112HJKLFGA5E.P11211211112A.F.F.APC-110' -0"551' - 0"A.F.F.APC-110' -0"A.F.F.GWB9' -10"A.F.F.GWB9' -10"1' - 0"8"135.00°7"7771AA-60088REFLECTED CEILING PLAN LEGENDAPC-12' X 2' AcousticalPanel Ceiling (09 51 13)GWB5/8" GWB on Grid Suspension System(09 22 16)Walls to DeckLight Fixture (Reference E-Series Dwgs)Return Air(Reference M-Series Dwgs)Supply Air(Reference M-Series Dwgs)Exit Light(Reference E-Series Dwgs)Recessed Light Fixture Suspended Fixture in Areas with Exposed Ceilings (Reference E-Series Dwgs)SSOUND SYSTEM SPEAKER (REFERENCE E-SERIES/T-SERIES DWGS)0' - 8" MIN.REF. PLANS0' - 8" MIN.09 29 00.B7 -INT GWB, 5/8" TYPE X09 22 16.C6 -INT STEEL STUDFRAMING, 3-5/8" @ 16" O.C.09 51 13.A2 -CEILING FINISH, REFARCHITECTURAL CEILING PLANSREF. PLANSN123456ABCDE123456ABCDEProject No.Project DateProducedThese Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect.KEY PLANBA5/22/2023 2:33:36 PMC:\_RevitLocal\2023-067.POR_Bldg001_A_2023\2023-067.POR_Bldg001_A_2023_mmiller.rvt2023-067.POR05.22.2023FIRST FLOORREFLECTED CEILINGPLAN -UNIT AAC1A1MWCoram DeoAcademyPhase OneRenovations2023-067.POR_Coram Deo Academy_Phase One Renovations_525 Congressional Blvd,Carmel, IN 46032AC1A1_ FIRST FLOOR REFLECTED CEILING PLAN -UNIT AREFLECTED CEILING PLAN NOTES#NOTE1EXISTING CEILING TO REMAIN. MODIFY AS REQUIRED TO ACCOMMODATE NEWCONSTRUCTION2NEW GWB BULKHEAD 4" BELOW EXISTING CEILING. REF TYPICAL DETAILS.3NEW ACOUSTIC CEILING TILES TO MATCH APC-1 IN EXISTING GRID. REPAINT GRIDWHITE, COLOR SELECTED BY ARCHITECT.4NOT USED5NEW CEILING GRID TO MATCH EXISTING ADJACENT CEILING. MATCH EXISTINGCEILING HEIGHT AND TYPE. INTEGRATE NEW CEILING GRID INTO EXISTING GRIDPATTERN. V.I.F.6BASE BID: EXISTING CEILINGS TO REMAIN; NEW GWB BULKHEAD 4" BELOWEXISTING ADJACENT CEILINGS. REF TYPICAL DETAILS. ROOM B137 ALTERNATE:NEW LAY-IN CEILING TO MATCH EXISTING ADJACENT CEILING HEIGHT ANDCONFIGURATION. V.I.F.7ALIGN FACE OF BULKHEAD WITH FACE OF ADJACENT WALL8BULKHEAD TO RECEIVE PAINT, P-2, IN ITS ENTIRETY.1/8" = 1'-0"1AREFLECTED CEILING PLAN -UNIT A1 1/2" = 1'-0"3ETYPICAL BULKHEAD DETAIL#RevisionDate VVVSF HMSFHVVVVHHVVVHMVO1O1O1O1VA. All ceilings are at 10'-0" AFF, unless noted otherwise.B. All bulkheads are at 9'-10" AFF, unless noted otherwise.C. All grids are centered in rooms, unless noted otherwise.D. All exposed ductwork, piping etc. shall be painted. Color selected by Architect.E. Locate sprinkler heads in center of ceiling panel -where applicable.F. Bulkheads to receive paint, P-1, in its entirety unless otherwise noted. General Refl. Ceiling Plan NotesREFLECTED CEILING PLAN LEGENDAPC-12' X 2' AcousticalPanel Ceiling (09 51 13)GWB5/8" GWB on Grid Suspension System(09 22 16)Walls to DeckLight Fixture (Reference E-Series Dwgs)Return Air(Reference M-Series Dwgs)Supply Air(Reference M-Series Dwgs)Exit Light(Reference E-Series Dwgs)Recessed Light Fixture Suspended Fixture in Areas with Exposed Ceilings (Reference E-Series Dwgs)SSOUND SYSTEM SPEAKER (REFERENCE E-SERIES/T-SERIES DWGS)55AA2211BBCCDDGGA5A5A4A4A3A3A2A2A1A1E.PE.P5A21BCDGA5A4A3A2A1E.P311221111232211121112211111115651' - 0"A.F.F.APC-110' -0"A.F.F.GWB9' -10"A.F.F.GWB9' -10"A.F.F.GWB9' -10"A.F.F.GWB9' -10"1' - 0"8"135.00°7"77777788882N123456ABCDE123456ABCDEProject No.Project DateProducedThese Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect.KEY PLANBA5/22/2023 2:33:49 PMC:\_RevitLocal\2023-067.POR_Bldg001_A_2023\2023-067.POR_Bldg001_A_2023_mmiller.rvt2023-067.POR05.22.2023FIRST FLOORREFLECTED CEILINGPLAN -UNIT BAC1B1MWCoram DeoAcademyPhase OneRenovations2023-067.POR_Coram Deo Academy_Phase One Renovations_525 Congressional Blvd,Carmel, IN 46032AC1B1_ FIRST FLOOR REFLECTED CEILING PLAN -UNIT BREFLECTED CEILING PLAN NOTES#NOTE1EXISTING CEILING TO REMAIN. MODIFY AS REQUIRED TO ACCOMMODATE NEWCONSTRUCTION2NEW GWB BULKHEAD 4" BELOW EXISTING CEILING. REF TYPICAL DETAILS.3NEW ACOUSTIC CEILING TILES TO MATCH APC-1 IN EXISTING GRID. REPAINT GRIDWHITE, COLOR SELECTED BY ARCHITECT.4NOT USED5NEW CEILING GRID TO MATCH EXISTING ADJACENT CEILING. MATCH EXISTINGCEILING HEIGHT AND TYPE. INTEGRATE NEW CEILING GRID INTO EXISTING GRIDPATTERN. V.I.F.6BASE BID: EXISTING CEILINGS TO REMAIN; NEW GWB BULKHEAD 4" BELOWEXISTING ADJACENT CEILINGS. REF TYPICAL DETAILS. ROOM B137 ALTERNATE:NEW LAY-IN CEILING TO MATCH EXISTING ADJACENT CEILING HEIGHT ANDCONFIGURATION. V.I.F.7ALIGN FACE OF BULKHEAD WITH FACE OF ADJACENT WALL8BULKHEAD TO RECEIVE PAINT, P-2, IN ITS ENTIRETY.1/8" = 1'-0"2AREFLECTED CEILING PLAN -UNIT B#RevisionDate F12"2"2"SEE SCHED.SEE SCHED.F-2F-39' - 2" V.I.F.2" TYP.SEE SCHED.SEE SCHED.7' - 6" V.I.F.3' - 3" V.I.F.1" TYP.F-47' - 6" V.I.F.6' - 0" V.I.F.1" TYP.4"4"SEE SCHED.SEE SCHED.FGSEE SCHED.SEE SCHED.6"6"3' - 6"GENERAL NOTESA. This Door Schedule(s) is furnished for whatever assistance it may afford the Contractor. Do not consider it as entirely inclusive. Carefully examine the Drawings (especially the Floor Plans) and the Specifications to determine the extent of door and frame quantities required (including interior borrowed lite or sidelite openings). Should any particular door, frame, or interior borrowed lite or sidelite shown on the Drawings be inadvertently omitted from this Schedule, supply same as required for similar openings. B. The "QTY" column designates the number of leaves in the opening. The "Door Width" column designates the total width of all leaves. In multiple leaf conditions, the leaves shall equally divide the "Door Width" unless noted otherwise; however, the active leaf shall not be less than 3'-0" wide.C. Verify locksets with the Owner during submittals.ABBREVIATIONSAL AluminumHM Hollow MetalST SteelWD WoodTG Tempered GlazingIG Insulated GlazingLG Laminated GlazingFG Frosted GlazingSP Spandrel PanelDOOR & FRAME SCHEDULE NOTESSee Door Schedule1. New door in existing frame. Field verify dimensions prior to fabrication. Provide new continuous aluminum hinge confirming to ANSI/BHMA A156.26, Grade 1. provide hinges 1" shorter than nominal height of door with symmetrical hole pattern. Glazing type and finish to match existing adjacent glazing.2. Salvaged existing door and frame. Field verify size and type. 3. All hardware is Existing to Reamin unless noted otherwise. 09 29 00.B7 -INT GWB, 5/8" TYPE X09 22 16.C6 -INT STEEL STUDFRAMING, 3-5/8" @ 16" O.C.EXISTING CEILING TO REMAIN. CUT CEILING PANELS AS REQUIRED FOR NEW WALL CONSTRUCTION.EXTEND GWB TO BOTTOM OF GRID09 29 00.G1 -SOUND ATTENUATIONBLANKET09 29 00.B7 -INT GWB, 5/8" TYPE X09 22 16.C6 -INT STEEL STUDFRAMING, 3-5/8" @ 16" O.C.EXISTING CEILING TO REMAIN. CUT CEILING PANELS AS REQUIRED FOR NEW WALL CONSTRUCTION.EXTEND GWB TO BOTTOM OF GRIDPLANSSEE09 29 00.B7 -INT GWB, 5/8" TYPE X09 22 16.C10 -METAL STUD BOXBEAM07 92 00.B3 -JOINT SEALANT (BOTHSIDES)08 11 13.A1 -DOOR & FRAME, REFDOOR SCHEDULE1/2"1/2"PLANSSEE09 29 00.B7 -INT GWB, 5/8" TYPE X09 22 16.C11 -DOUBLE STUDS07 92 00.B3 -JOINT SEALANT (BOTHSIDES)08 11 13.A1 -DOOR & FRAME, REFDOOR SCHEDULE1/2"1/2"34" MIN. TO 38" MAX.34" MIN. TO 38" MAX.34" MIN. TO 38" MAX.EXISTING PIPE HANDRAIL TO BE REMOVED, REPAIRED, AND REATTACHED TO EXISTING EXTERIOR STAIR. FIELD VERIFY ALL CONDITIONS. REMOVE DAMAGED PORTION OF RAIL BEFORE REINSTALLATION. WELD TO NEW FLANGE ATTACHMENT AND BOLT TO EXISTING STAIR. RAILINGS SHALL WITHSTAND THE EFFECTS OF GRAVITY LOADS AND THE FOLLOWING LOADS AND STRESSES WITHIN LIMITS NAD UNDER CONDITIONS INDICATED:HANDRAILS AND TOP RAILS OF GUARDS: UNIFORM LOAD OF 50 LBF/FT APPLIED IN ANY DIRECTION AND CONCENTRATED LOAD OF 200 LBF APPLIED IN ANY DIRECTION. INFILL OF GUARDS: CONCENTRATED LOAD OF 50 LBF APPLIED HORIZONTALLY ON AN AREA OF 1 SQ. FT.UNIFORM, CONCENTRATED, AND INFILL LOADS NEED NOT BE ASSUMED TO ACT CONCURRENTLYREMOVE EXISTING METAL FINISH AND PREP FOR NEW HIGH PERFORMANCE COATING SYSTEM. PROVIDE SHOP AND FIELD PRIMERS, AND FINISH-COAT MATERIALS THAT ARE COMPATIBLE WITH EACH OTHER AND WITH EXISTING SUBSTRATE UNDER CONDITIONS OF SERVICE AND APPLICATION, AS DEMONSTRATED BY MANUFACTURER BASED ON TESTING AND FIELD EXPERIENCEEXISTING CONCRETE STAIR, V.I.F.PLANSSEE09 22 16.C10 -METAL STUD BOXBEAM07 92 00.B3 -JOINT SEALANT (BOTHSIDES)08 11 13.A1 -DOOR & FRAME, REFDOOR SCHEDULE1/2"1/2"MATCH EXISTING ADJACENT WALL CONSTRUCTION AND FINISH. PATCH TO CREATE SEAMLESS TRANSITION FROM EXISTING TO NEW MATERIAL.PLANSSEE09 22 16.C11 -DOUBLE STUDS07 92 00.B3 -JOINT SEALANT (BOTHSIDES)08 11 13.A1 -DOOR & FRAME, REFDOOR SCHEDULE1/2"1/2"MATCH EXISTING ADJACENT WALL CONSTRUCTION AND FINISH. PATCH TO CREATE SEAMLESS TRANSITION FROM EXISTING TO NEW MATERIAL.PLANSSEE09 29 00.B7 -INT GWB, 5/8" TYPE X09 22 16.C10 -METAL STUD BOXBEAM07 92 00.B3 -JOINT SEALANT (BOTHSIDES)EQEQSALVAGED INTERIOR GLASS PANE. ALL GLASS WITHIN 18" A.F.F. SHALL BE SAFETY GLAZING06 40 23 -1X FINISHED WOOD TRIM.EXTEND LESS THAN 1/2" BEYONDFACE OF ADJACENT WALL06 10 53.B2 -WOOD BLOCKING, 2XCONTINUOUS09 29 00 -GWB REVEAL, 3/4" BASISOF DESIGN FRY REGLETDRMZ-625-75PLANSSEE09 29 00.B7 -INT GWB, 5/8" TYPE X07 92 00.B3 -JOINT SEALANT (BOTHSIDES)EQEQSALVAGED INTERIOR GLASS PANE. ALL GLASS WITHIN 18" A.F.F. SHALL BE SAFETY GLAZING06 40 23 -1X FINISHED WOOD TRIM.EXTEND LESS THAN 1/2" BEYONDFACE OF ADJACENT WALL06 10 53.B2 -WOOD BLOCKING, 2XCONTINUOUS09 29 00 -GWB REVEAL, 3/4" BASISOF DESIGN FRY REGLETDRMZ-625-7509 22 16.C11 -DOUBLE STUDS07 92 00.B3 -JOINT SEALANT (BOTHSIDES)SALVAGED INTERIOR GLASS PANE. ALL GLASS WITHIN 18" A.F.F. SHALL BE SAFETY GLAZING06 40 23 -1X FINISHED WOOD TRIM.EXTEND LESS THAN 1/2" BEYONDFACE OF ADJACENT WALL06 40 23.K1 -1X FINISHED WOODTRIMCONSTRUCTION OR NO 2 GRADE 2X4DIMENSIONAL LUMBER, ANYSPECIES.4 1/4"EXISTING FLOOR CONSTRUCTION AND FINISH, V.I.F.RUBBER GASKET09 29 00.B9 -INT GWB, 5/8" TYPE XEACH SIDE09 22 16.C6 -INT STEEL STUDFRAMING, 3-5/8" @ 16" O.C.09 22 16.C13 -DEFLECTION TRACKSECURE FRAMING TO DECK/STRUCTURE ABOVELevel 10' -0"Level 10' -0"Level 10' -0"Level 10' -0"SCIENCE LABA121BREAK ROOMA106S4-DEXISTING WALL CONSTRUCTION, V.I.F.REMOVE EXISTING ACOUSTICAL CEILING AS REQUIRED FOR CONSTRUCTION. PATCH AND REPAIR CEILING TO CREATE A SEAMLES TRANSITION FROM EXISTING TO NEW CEILING. V.I.F.10' - 8" V.I.F.09 51 13.A2 -CEILING FINISH, REFARCHITECTURAL CEILING PLANSNRIUDOOR & FRAME SCHEDULEMARKDOOR PANELFRAMELABELHDWRSETNOTESMARKTYPEQTYMATLGLAZSIZEMARKMATLGLAZHWTHA110.1F1WD--7' - 0"3' - 0"0' - 1 3/4"F1HM--ETR2A110.1A110.2F1WD--7' - 0"3' - 0"0' - 1 3/4"F1HM--ETR2A110.2A110.3G1ALIG7' - 0"3' - 0"0' - 1 3/4"EXISTEXISTEXISTETR1A110.3A110.4F1WD--7' - 0"3' - 0"0' - 1 3/4"F1WD--ETR2A110.4B126F1WD--7' - 0"3' - 0"0' - 1 3/4"F2HMTGETR2B126B130F1WD--7' - 0"3' - 0"0' - 1 3/4"F2HMTGETR2B130B137F1WD--7' - 0"3' - 0"0' - 1 3/4"F2HMTGETR2B1371/4" = 1'-0"5.4.603 -FRAME ELEVATIONS1/4" = 1'-0"5.4.602 -DOOR PANEL ELEVATIONSN123456ABCDE123456ABCDEProject No.Project DateProducedThese Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect.KEY PLANBA5/22/2023 2:34:01 PMC:\_RevitLocal\2023-067.POR_Bldg001_A_2023\2023-067.POR_Bldg001_A_2023_mmiller.rvt2023-067.POR05.22.2023SCHEDULES & DETAILSA-600MWCoram DeoAcademyPhase OneRenovations2023-067.POR_Coram Deo Academy_Phase One Renovations_525 Congressional Blvd,Carmel, IN 46032A-600_ SCHEDULES & DETAILS1 1/2" = 1'-0"6ES4-C WALL TYPE1 1/2" = 1'-0"5ES4iC WALL TYPE1 1/2" = 1'-0"6DHEAD1 1/2" = 1'-0"6CJAMB1 1/2" = 1'-0"3AEXISTING RAIL ELEVATION1 1/2" = 1'-0"5DHEAD1 1/2" = 1'-0"5CJAMB1 1/2" = 1'-0"4EHEAD1 1/2" = 1'-0"4DJAMB1 1/2" = 1'-0"4CSILL3/4" = 1'-0"1AWALL SECTION @ SCIENCE LAB1 1/2" = 1'-0"6BS4-D WALL TYPE#RevisionDate TS A. B. C. D. E. F. G. H. I. J. K. INTERIOR GENERAL NOTES FINISHES PRIOR TO START & FINAL COMPLETION OF WORK • Where existing finishes are to remain outside scope of work, patch & repair any area damaged or effected by renovation, to return to like new condition, matching adjacent finishes. This includes, but is not limited to doors & associated hardware, door frames, wall finishes, wall base, floor finish including floor transitions & thresholds, etc. It is the responsibility of the contractor to verify conditions in field prior to start & completion of work. Interior Painting/Wallcovering • Existing wall conditions that were not specifically noted to be patched and repaired, but are designated to receive new finishes, are to be repaired prior to new finishes being applied. It is the Contractors responsibility to confirm conditions in field prior to start of work. • Vinyl Wall Base over gyp. - Prior to removal of existing vinyl wall base, score wall above top of base to minimize damage to drywall. Reference architectural ceilings plans for ceiling heights and bulkhead color designations. Paint all bulkheads HP-1 or P-1 (neutral to match existing) unless specifically noted otherwise. Bulkheads that are flush with walls provide color to match adjacent wall color. Paint interior hollow metal door frames high performance (HP) paint to match existing. Paint all exposed conduit, piping, and associated assemblies to match adjacent paint finish. Applies to all new & existing to remain in areas of renovation or new construction. Paint general walls HP-1 or P-1 (Neutral to match existing) unless specifically noted otherwise, only in areas that have been affected by demolition. Wall Base 1. Install vinyl wall base on top of rigid wall protection. Provide caulk joint at floor level, typ. 2. Provide vinyl wall base around all casework unless specicially noted otherwise 3. Provide new vinyl wall base to match existing on new wall construction. Where floor finish transitions between rooms, align transition centered with threshold of door unless noted otherwise. 1. LVT to carpet does not require transition strip, products will abutt at same height. Science classroom: epoxy top student tables, stools, mobile teacher demo station, and chemical storage units are included in this contract. Appliances and vending equipment are not provided in this contract. Visual display boards (marker and tack boards) to be mounted at 3' - 0" A.F.F. I-201 2E2C I-201 2A 2D GYM A110 WALL:ETR FLOOR:ETR BASE:ETR/VWB-1 CLASSROOM B117 CLASSROOM B115 RR A110C CORRIDOR A002 STORAGE A110A CLASSROOM A116 WALL:ETR FLOOR:ETR BASE:ETR CLASSROOM A120 WALL:ETR FLOOR:ETR BASE:ETR SCIENCE LAB A121 WALL:P-1,2 FLOOR:RF-1,2 BASE:RFB-1,2 CLASSROOM A118 OFFICE A119 01 04 CAFETERIA B111A 08 CLASSROOM B120 CLASSROOM B110 CLASSROOM A113 STORAGE B112 STORAGE A112 STORAGE A111 STORAGE A117 BREAK ROOM A106 PRACTICE ROOM B117A PRACTICE ROOM B116 PRACTICE ROOM B114 PRACTICE ROOM B113 WOMENS RR B104 WOMENS RR A108 MENS RR A109 MENS RR B103 ELECTRICAL A112A UNOCCUPIED A130 UNOCCUPIED A129 UNOCCUPIED A128 UNOCCUPIED A127 UNOCCUPIED A126 UNOCCUPIED A125 UNOCCUPIED A124 UNOCCUPIED A123 UNOCCUPIED A122 STORAGE A106A STORAGE B102 STORAGE A103A JANITOR A107 RISER RM A108A OFFICE A102 OFFICE A103 OFFICE A104 OFFICE B105 OFFICE B106 OFFICE B107 OFFICE B108 OFFICE B115A STORAGE B115B STORAGE B115C OFFICE A105 VESTIBULE A110B VESTIBULE A100A VESTIBULE B111B CORRIDOR A003 CORRIDOR A001 VESTIBULE A003A CLINIC A101 PARENT ROOM B100 COPIER B109 LOBBY A100 VESTIBULE A003B STORAGE B101 OFFICE A115 OFFICE A114 PRACTICE ROOM B114 LOBBY A100 09 11 11 12 13 14 14 1511 EQ.EQ.05 06 17 12" MIN CLR. MB10 20 2B 5C 5B I-201 5A 4 3/4"Interior Floor Pattern Legend RF-1 Resilient Sheet Flooring LVT-1 (12" X 24") Luxury Vinyl Tile RF-2 LVT-2 (12" X 24") N 123456 A B C D E 123456 A B C D E Project No. Project Date Produced These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect. KEY PLAN B A 5/22/2023 3:25:17 PMC:\_RevitLocal\2023-067.POR_Bldg001_A_2023\2023-067.POR_Bldg001_A_2023_kroche.rvt2023-067.POR 05.22.2023 FIRST FLOOR INTERIOR FINISH PLAN IN1A1 KER Coram Deo Academy Phase One Renovations 2023-067.POR_Coram Deo Academy_Phase One Renovations_525 Congressional Blvd, Carmel, IN 46032 IN1A1_ FIRST FLOOR INTERIOR FINISH PLAN5.5.100 - INTERIOR FINISH LEGEND MARK DESCRIPTION MANUFACTURE R COLLECTION/PA TTERN COLOR COMMENTS FLOORING LVT-1 LUXURY VINYL TILE MOHAWK GROUP LIVING LOCAL/TERRAZZO VESUVIUS 723 SIZE: 12 BY 24 INCHES; INSTALL: BRICK ASHLAR; INSTALLED IN CAFETERIA AS ALT. LVT-2 LUXURY VINYL TILE MOHAWK GROUP LIVING LOCAL/CHROMASCOPE FIRETRUCK RED 550 SIZE: 12 BY 24 INCHES; INSTALL: BRICK ASHLAR; INSTALLED IN CAFETERIA AS ALT. RF-1 RUBBER SHEET FLOORING MANNINGTON COLORFIELDS SONIC 896 SIZE: 4 BY 50 FEET; INSTALL: HEAT WELDED SEAMS WITH 4 INCH INTEGRAL COVE BASE. RF-2 RUBBER SHEET FLOORING MANNINGTON COLORFIELDS CUMULUS 884 SIZE: 4 BY 50 FEET; INSTALL: HEAT WELDED SEAMS WITH 4 INCH INTEGRAL COVE BASE. VWB-1 VINYL WALL BASE FLEXCO --SIZE: 4" COVE BASE IN COIL FORM. VCT-1 VINYL COMPOSITION TILE ARMSTRONG FLOORING PREMIUM EXCELON/CROWN TEXTURE 5C908 PEWTER SIZE: 12 BY 12 INCHES; INSTALL: MONOLITHIC; INSTALLED IN CAFETERIA AS BASE BID ONLY. FURNISHINGS RWS-1 ROLLER WINDOW SHADES DRAPER 3% OPENNESS MATCH EXISTING LOCATION(S): ALL EXTERIOR CLASSROOM WINDOWS THAT DO NOT ALREADY HAVE SHADES INSTALLED. PL-1 PLASTIC LAMINATE PIONITE TEXTURED/SUEDE OLD FRIEND AG415-SD LOCATION(S): SCIENCE PERIMETER CASEWORK WALLS P-1 PAINT (FIELD) SHERWIN WILLIAMS -- MATCH EXISTING (GENERAL NEUTRAL) LOCATION(S): WHERE INDICATED P-2 PAINT (ACCENT) SHERWIN WILLIAMS -- BOLERO SW7600 LOCATION(S): WHERE INDICATED HP-1 HIGH PERFORMANCE PAINT SHERWIN WILLIAMS -- MATCH EXISTING DOOR FRAMES AND RAILINGS FLOOR PLAN NOTES # Note 01 ALIGN FACE OF NEW WALL/INFILL WITH ADJACENT WALL FACE. 02 INFILL OPENING WITH WALL TO MATCH SURROUNDING/ADJACENT WALL CONSTRUCTION. VERIFY EXISTING WALL CONDITIONS/CONSTRUCTION AND DIMENSIONS IN THE FIELD. ALIGN THE FACE OF THE NEW INFILL WALL WITH THE ADJACENT EXISTING WALL FACE. 03 INTERIOR WOODFRAMED WINDOW WITH GLAZING. REF A-600 FOR SIZE AND DETAILS 04 RELOCATED EXISTING DOOR AND FRAME, REF A-600 SERIES FOR SIZE AND TYPE. 05 BASE BID: EXISTING FLOORING TO REMAIN; PATCH AREAS AFFECTED BY DEMOLITION WITH SALVAGED OR NEW TO MATCH EXISTING CARPET TILE. SCIENCE LAB ALTERNATE: SCIENCE LAB EQUIPMENT, CASEWORK AND RESILIENT SHEET FLOORING AS SHOWN. 06 NEW DOOR IN EXISTING FRAME WITH NEW CONTINUOUS ALUMINUM HINGE. REF DOOR SCHEDULE FOR SIZE. VERIFY IN FIELD. 07 REATTACH EXISTING RAILING TO EXISTING CONCRETE STAIR; REF DETAILS 08 GYMNASIUM WALL PADS, 2' L X 4' H. WRAP ALL OUTSIDE CORNERS AND EDGES TO CREATE A CONTINUOUS RUN. 09 RUBBER TILE USED FOR INFILL POST DEMOLITION ARE TO MATCH EXISTING. 10 FOLLOWING DEMOLITION, FLOORING ON GROUND IS TO BE VINYL COMPOSITION TILE, VCT. VCT IS TO ABUTT TO EXISTING VCT AND IS TO MATCH EXISTING. 11 AREAS AFFECTED BY DEMOLITION ARE TO RECEIVE CARPET TILE. CARPET TILES ARE TO MATCH EXISTING 12 EYEWASH STATION; REF P-SERIES DWGS. 13 BASE BID: GYMNASIUM WALL PADS BELOW SILL. GYMNASIUM WALL ALTERNATE: NEW WALL CONSTRUCTION IN FRONT OF EXISTING WINDOWS; REF SECTION DETAILS. 14 WRAP CORNER WITH GYMNASIUM WALL PADS; TERMINATE AT FACE OF EXISTING STOREFRONT. 15 NEW UTILITY SINK- REF P-DWGS 16 BASE BID: EXISTING DOOR AND FRAME TO REMAIN. MUSIC DOOR ALTERNATE: RELOCATED DOOR AND NEW WALL CONSTRUCTION AS SHOWN. REF DOOR SCHEDULE FOR SIZE AND TYPE 17 BASE BID: EXISTING DOOR TO REMAIN. SCIENCE LAB ALTERNATE: REMOVE EXISTING DOOR AND APPLY PLAN NOTE 2. 18 FOLLOWING DEMOLITION, FLOORING ON GROUND IS TO BE CARPET TILE, CPT-1 (MATCH EXISTING). EXISTING VCT IS TO BE DEMOLISHED OR COVERED WITH CPT-1. 19 EXISTING FLOORING FINISH ON RISERS AND FABRIC-WRAPPED WALL PANELS ARE TO BE EXISTING TO REMAIN. 20 WALL TO RECEIVE PAINT, P-2, INSIDE CORNER TO INSIDE CORNER. 21 BASE BID: 4 OFFICES COMBINED INTO 1 SPACE, REF DEMOLITION PLANS. ROOM B137 ALTERNATE: NEW WALL CONSTRUCTION AS SHOWN. 22 RELOCATED FIRE PANEL. COORDINATE FINAL LOCATION WITH OWNER IN FIELD. 23 SCIENCE LAB ALTERNATE: NEW DRYWALL ON EXISTING STUD TO DECK, BOTH SIDES OF THE WALL. REF WALL SECTIONS AND DETAILS. 24 PATCH AND REPAIR EXISTING GWB TO CREATE A SEAMLESS, SMOOTH TRANSITION. PREP FOR FINISH 25 NEW FLOORING (LVT) TO ALIGN WITH NEW BULKHEADS. 26 MECHANICAL HOOD. BASIS OF DESIGN ELIMINATOR 500 SERIES ADA DESIGN. PART # EH-511-72.INCLUDE (1) CORROSIVE AND (1) FLAMMABLE BASE CABINET BELOW. REF M-SERIES DWGS 27 NEW DOOR CLOSER ON EXISTING DOOR. BASIS OF DESIGN LCN 1250 SERIES. 28 NEW STAINLESS STEEL KICK PLATE MOUNED TO FACE OF ALUMINUM EXTERIOR DOOR. EXTEND MIN 1" BEYOND EDGE OF GLASS IN DOOR AND TO BOTTOM OF EXIT DEVICE. ATTACH WITH COMPATIBLE METAL SCREWS INSTALLED IN FOAM GASKET; COUNTERINK ALL HOLES IN EXISTING DOOR. SEPARATE DISSIMILAR METALS WITH NON CORROSIVE MATERIALS. FIELD VERIFY. 1/8" = 1'-0"1A FIRST FLOOR INTERIOR FLOOR PLAN - UNIT A # Revision Date TS TSTSTS DN PRE-K B132 WALL:ETR FLOOR:ETR BASE:ETR OFFICE B131 CLASSROOM B130 WALL:ETR FLOOR:ETR BASE:ETR CLASSROOM B126 WALL:ETR FLOOR:ETR BASE:ETR CORRIDOR B001 CLASSROOM B121 WALL:ETR FLOOR:ETR BASE:ETR CLASSROOM B127 WALL:ETR FLOOR:ETR BASE:ETR LIBRARY B135 WALL:ETR/P-1 FLOOR:CPT-1 BASE:VWB-1 COMMONS B141 WALL:P-1 FLOOR:CPT-1 BASE:VWB-1 CLASSROOM B145 WALL:ETR FLOOR:ETR BASE:ETR CLASSROOM B138 CLASSROOM B137 CHAPEL B111 02 03 03 01 01 01 01 CAFETERIA B111A WALL:ETR FLOOR:LVT-1 BASE:VWB-1 07 CHAPEL B111 WALL:ETR FLOOR:ETR BASE:ETR CLASSROOM B120 CLASSROOM B110 STORAGE B112 OFFICE B108 KITCHENETTE B122 VESTIBULE B111B CORRIDOR B001 PARENT ROOM B100 COPIER B109 CLASSROOM B136 CLASSROOM B118 CLASSROOM B119 STORAGE B146A WOMENS RR B148 MENS RR B149 RR B134 PLUMBING B123 IDF B129 STORAGE B139 STORAGE B140 STORAGE B142 STORAGE B143 STORAGE B144 STORAGE B129A STORAGE B129B OFFICE B147 OFFICE B119A OFFICE B124 KITCHEN B128 KITCHENETTE B133 WALL:ETR/P-1 FLOOR:ETR BASE:ETR STORAGE B146 03 01 18 11 11 11 11 11 19 25 25 ALIGN ALIGN TYP.4' - 0"TYP.4' - 0".A. B. C. D. E. F. G. H. I. J. K. INTERIOR GENERAL NOTES FINISHES PRIOR TO START & FINAL COMPLETION OF WORK • Where existing finishes are to remain outside scope of work, patch & repair any area damaged or effected by renovation, to return to like new condition, matching adjacent finishes. This includes, but is not limited to doors & associated hardware, door frames, wall finishes, wall base, floor finish including floor transitions & thresholds, etc. It is the responsibility of the contractor to verify conditions in field prior to start & completion of work. Interior Painting/Wallcovering • Existing wall conditions that were not specifically noted to be patched and repaired, but are designated to receive new finishes, are to be repaired prior to new finishes being applied. It is the Contractors responsibility to confirm conditions in field prior to start of work. • Vinyl Wall Base over gyp. - Prior to removal of existing vinyl wall base, score wall above top of base to minimize damage to drywall. Reference architectural ceilings plans for ceiling heights and bulkhead color designations. Paint all bulkheads HP-1 or P-1 (neutral to match existing) unless specifically noted otherwise. Bulkheads that are flush with walls provide color to match adjacent wall color. Paint interior hollow metal door frames high performance (HP) paint to match existing. Paint all exposed conduit, piping, and associated assemblies to match adjacent paint finish. Applies to all new & existing to remain in areas of renovation or new construction. Paint general walls HP-1 or P-1 (Neutral to match existing) unless specifically noted otherwise, only in areas that have been affected by demolition. Wall Base 1. Install vinyl wall base on top of rigid wall protection. Provide caulk joint at floor level, typ. 2. Provide vinyl wall base around all casework unless specicially noted otherwise 3. Provide new vinyl wall base to match existing on new wall construction. Where floor finish transitions between rooms, align transition centered with threshold of door unless noted otherwise. 1. LVT to carpet does not require transition strip, products will abutt at same height. Science classroom: epoxy top student tables, stools, mobile teacher demo station, and chemical storage units are included in this contract. Appliances and vending equipment are not provided in this contract. Visual display boards (marker and tack boards) to be mounted at 3' - 0" A.F.F. Interior Floor Pattern Legend RF-1 Resilient Sheet Flooring LVT-1 (12" X 24") Luxury Vinyl Tile RF-2 LVT-2 (12" X 24") N 123456 A B C D E 123456 A B C D E Project No. Project Date Produced These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect. KEY PLAN B A 5/22/2023 3:25:18 PMC:\_RevitLocal\2023-067.POR_Bldg001_A_2023\2023-067.POR_Bldg001_A_2023_kroche.rvt2023-067.POR 05.22.2023 FIRST FLOOR INTERIOR FINISH PLAN IN1B1 KER Coram Deo Academy Phase One Renovations 2023-067.POR_Coram Deo Academy_Phase One Renovations_525 Congressional Blvd, Carmel, IN 46032 IN1B1_ FIRST FLOOR INTERIOR FINISH PLAN1/8" = 1'-0"1A FIRST FLOOR INTERIOR FLOOR PLAN - UNIT B 5.5.100 - INTERIOR FINISH LEGEND MARK DESCRIPTION MANUFACTURE R COLLECTION/PA TTERN COLOR COMMENTS FLOORING LVT-1 LUXURY VINYL TILE MOHAWK GROUP LIVING LOCAL/TERRAZZO VESUVIUS 723 SIZE: 12 BY 24 INCHES; INSTALL: BRICK ASHLAR; INSTALLED IN CAFETERIA AS ALT. LVT-2 LUXURY VINYL TILE MOHAWK GROUP LIVING LOCAL/CHROMASCOPE FIRETRUCK RED 550 SIZE: 12 BY 24 INCHES; INSTALL: BRICK ASHLAR; INSTALLED IN CAFETERIA AS ALT. RF-1 RUBBER SHEET FLOORING MANNINGTON COLORFIELDS SONIC 896 SIZE: 4 BY 50 FEET; INSTALL: HEAT WELDED SEAMS WITH 4 INCH INTEGRAL COVE BASE. RF-2 RUBBER SHEET FLOORING MANNINGTON COLORFIELDS CUMULUS 884 SIZE: 4 BY 50 FEET; INSTALL: HEAT WELDED SEAMS WITH 4 INCH INTEGRAL COVE BASE. VWB-1 VINYL WALL BASE FLEXCO --SIZE: 4" COVE BASE IN COIL FORM. VCT-1 VINYL COMPOSITION TILE ARMSTRONG FLOORING PREMIUM EXCELON/CROWN TEXTURE 5C908 PEWTER SIZE: 12 BY 12 INCHES; INSTALL: MONOLITHIC; INSTALLED IN CAFETERIA AS BASE BID ONLY. FURNISHINGS RWS-1 ROLLER WINDOW SHADES DRAPER 3% OPENNESS MATCH EXISTING LOCATION(S): ALL EXTERIOR CLASSROOM WINDOWS THAT DO NOT ALREADY HAVE SHADES INSTALLED. PL-1 PLASTIC LAMINATE PIONITE TEXTURED/SUEDE OLD FRIEND AG415-SD LOCATION(S): SCIENCE PERIMETER CASEWORK WALLS P-1 PAINT (FIELD) SHERWIN WILLIAMS -- MATCH EXISTING (GENERAL NEUTRAL) LOCATION(S): WHERE INDICATED P-2 PAINT (ACCENT) SHERWIN WILLIAMS -- BOLERO SW7600 LOCATION(S): WHERE INDICATED HP-1 HIGH PERFORMANCE PAINT SHERWIN WILLIAMS -- MATCH EXISTING DOOR FRAMES AND RAILINGS FLOOR PLAN NOTES # Note 01 ALIGN FACE OF NEW WALL/INFILL WITH ADJACENT WALL FACE. 02 INFILL OPENING WITH WALL TO MATCH SURROUNDING/ADJACENT WALL CONSTRUCTION. VERIFY EXISTING WALL CONDITIONS/CONSTRUCTION AND DIMENSIONS IN THE FIELD. ALIGN THE FACE OF THE NEW INFILL WALL WITH THE ADJACENT EXISTING WALL FACE. 03 INTERIOR WOODFRAMED WINDOW WITH GLAZING. REF A-600 FOR SIZE AND DETAILS 04 RELOCATED EXISTING DOOR AND FRAME, REF A-600 SERIES FOR SIZE AND TYPE. 05 BASE BID: EXISTING FLOORING TO REMAIN; PATCH AREAS AFFECTED BY DEMOLITION WITH SALVAGED OR NEW TO MATCH EXISTING CARPET TILE. SCIENCE LAB ALTERNATE: SCIENCE LAB EQUIPMENT, CASEWORK AND RESILIENT SHEET FLOORING AS SHOWN. 06 NEW DOOR IN EXISTING FRAME WITH NEW CONTINUOUS ALUMINUM HINGE. REF DOOR SCHEDULE FOR SIZE. VERIFY IN FIELD. 07 REATTACH EXISTING RAILING TO EXISTING CONCRETE STAIR; REF DETAILS 08 GYMNASIUM WALL PADS, 2' L X 4' H. WRAP ALL OUTSIDE CORNERS AND EDGES TO CREATE A CONTINUOUS RUN. 09 RUBBER TILE USED FOR INFILL POST DEMOLITION ARE TO MATCH EXISTING. 10 FOLLOWING DEMOLITION, FLOORING ON GROUND IS TO BE VINYL COMPOSITION TILE, VCT. VCT IS TO ABUTT TO EXISTING VCT AND IS TO MATCH EXISTING. 11 AREAS AFFECTED BY DEMOLITION ARE TO RECEIVE CARPET TILE. CARPET TILES ARE TO MATCH EXISTING 12 EYEWASH STATION; REF P-SERIES DWGS. 13 BASE BID: GYMNASIUM WALL PADS BELOW SILL. GYMNASIUM WALL ALTERNATE: NEW WALL CONSTRUCTION IN FRONT OF EXISTING WINDOWS; REF SECTION DETAILS. 14 WRAP CORNER WITH GYMNASIUM WALL PADS; TERMINATE AT FACE OF EXISTING STOREFRONT. 15 NEW UTILITY SINK- REF P-DWGS 16 BASE BID: EXISTING DOOR AND FRAME TO REMAIN. MUSIC DOOR ALTERNATE: RELOCATED DOOR AND NEW WALL CONSTRUCTION AS SHOWN. REF DOOR SCHEDULE FOR SIZE AND TYPE 17 BASE BID: EXISTING DOOR TO REMAIN. SCIENCE LAB ALTERNATE: REMOVE EXISTING DOOR AND APPLY PLAN NOTE 2. 18 FOLLOWING DEMOLITION, FLOORING ON GROUND IS TO BE CARPET TILE, CPT-1 (MATCH EXISTING). EXISTING VCT IS TO BE DEMOLISHED OR COVERED WITH CPT-1. 19 EXISTING FLOORING FINISH ON RISERS AND FABRIC-WRAPPED WALL PANELS ARE TO BE EXISTING TO REMAIN. 20 WALL TO RECEIVE PAINT, P-2, INSIDE CORNER TO INSIDE CORNER. 21 BASE BID: 4 OFFICES COMBINED INTO 1 SPACE, REF DEMOLITION PLANS. ROOM B137 ALTERNATE: NEW WALL CONSTRUCTION AS SHOWN. 22 RELOCATED FIRE PANEL. COORDINATE FINAL LOCATION WITH OWNER IN FIELD. 23 SCIENCE LAB ALTERNATE: NEW DRYWALL ON EXISTING STUD TO DECK, BOTH SIDES OF THE WALL. REF WALL SECTIONS AND DETAILS. 24 PATCH AND REPAIR EXISTING GWB TO CREATE A SEAMLESS, SMOOTH TRANSITION. PREP FOR FINISH 25 NEW FLOORING (LVT) TO ALIGN WITH NEW BULKHEADS. 26 MECHANICAL HOOD. BASIS OF DESIGN ELIMINATOR 500 SERIES ADA DESIGN. PART # EH-511-72.INCLUDE (1) CORROSIVE AND (1) FLAMMABLE BASE CABINET BELOW. REF M-SERIES DWGS 27 NEW DOOR CLOSER ON EXISTING DOOR. BASIS OF DESIGN LCN 1250 SERIES. 28 NEW STAINLESS STEEL KICK PLATE MOUNED TO FACE OF ALUMINUM EXTERIOR DOOR. EXTEND MIN 1" BEYOND EDGE OF GLASS IN DOOR AND TO BOTTOM OF EXIT DEVICE. ATTACH WITH COMPATIBLE METAL SCREWS INSTALLED IN FOAM GASKET; COUNTERINK ALL HOLES IN EXISTING DOOR. SEPARATE DISSIMILAR METALS WITH NON CORROSIVE MATERIALS. FIELD VERIFY. # Revision Date 2' - 6" SINK 3' - 0"2' - 6" SINK 3' - 0"2' - 6" SINK 3' - 0"3' - 0"1' - 6"3' - 6"8' - 0"12" D. 2 DR GLASS DR WALL CABINET, TYP. RECESSED EYEWASH STATION TO BE PROVIDED IN CONTRACT. SEE "P" SERIES DRWGS FOR DETAILS. MODEL SHOWN AS PLACEHOLDER ONLY. FUME HOOD TO BE PROVIDED IN CONTRACT. SEE "M" SERIES DRWGS FOR DETAILS. 31" D. EPOXY COUNTER- TOP. 6" CHASE DEPTH BEHIND CABINETS IS TO BE MAINTAINED. 24" D. 2 DR. BASE CABINET, TYP. 24" D. 2 DR SINK BASE, TYP. 2' - 6"3' - 0"2' - 6"3' - 0"2' - 6"2' - 6"FILL 2' - 6"3' - 0"3' - 7"30" BY 36" EPOXY PEG DRYING RACK. 14" D. +/- CORNER CABINET W/ADJ. SHELVES. 24" D. 4 DWR BASE CABINET. WALL TO RECEIVE RIGID WALL PROTECTION. BASIS- OF-DESIGN: ACROVYN 4' x 8' SHEETS DIRECT-GLUED TO WALL. COLOR: DRIFTWOOD #262 CLEAR 15" MIN.4' - 0" FILL FILL REF. SPECIFICATION AND CONFIGURATION SHEET FOR FUME HOOD DETAILS AND STORAGE CABINETS BELOW. 1' - 9"2' - 7"FILL BASIS-OF-DESIGN: JUSTRITE, 22 GAL, SURE-GRIP, UNDER COUNTER, MODEL# 892322 *ALL CASEWORK BASIS-OF-DESIGN: DIVERSIFIED WOODCRAFTS PLASTIC LAMINATE LABORATORY CASEWORK. WALL TO RECEIVE VINYL WALL BASE, VWB-1, TYP. SINK 3' - 0"2' - 6" SINK 3' - 0"2' - 6" 12" D. 2 DR GLASS DR WALL CABINET, TYP. 31" D. EPOXY COUNTERTOP. 6" CHASE DEPTH BEHIND CABINETS IS TO BE MAINTAINED. 24" D. 2 DR. BASE CABINET, TYP. 24" D. 2 DR SINK BASE, TYP. 8' - 0"2' - 10"1' - 8"3' - 0"2' - 6"3' - 0"3' - 6"CORNER 14" D. +/- CORNER CABINET W/ADJ. SHELVES.3' - 6"3' - 0"4' - 0"REFERENCE ARCHITECTURAL PLAN NOTES #13 AND #14 FOR DETAILS REGARDING WALL PADS.3' - 8"4"WALL TO RECEIVE VINYL WALL BASE, VWB-1, TO MATCH EXISTING. TYP. 2' - 0" MB10 EXISTING VISUAL DISPLAYS TO REMAIN AS-IS. MARKERBOARD TO BE RELOCATED FROM OTHER ROOM IN THE BUILDING. MOBILE TEACHER DEMO STATION, TO BE INCLUDED IN CONTRACT. BASIS-OF-DESIGN: DIVERSIFIED WOODCRAFTS KINETIC MOBILE DEMO TABLE WITH SINK AND STORAGE, #4332K TYP.4' - 0"TYP. 8' - 0" WALL TO RECEIVE RIGID WALL PROTECTION. BASIS- OF-DESIGN: ACROVYN 4' x 8' SHEETS DIRECT-GLUED TO WALL. COLOR: DRIFTWOOD #262 BREAK INDICATES SEAM; TO BE BUTT-JOINTED. REF. "E" SERIES DRWGS FOR COORDINATION OF SWITCHES/CONTROLS. WHERE THERE IS A CONFLICT, WALL PROTECTION IS TO BE CUT-OUT TO ALLOW FORSWITCH/CONTROL. 4"3' - 8"WALL TO RECEIVE VINYL WALL BASE, VWB-1, TYP. WALL TO RECEIVE RIGID WALL PROTECTION. BASIS- OF-DESIGN: ACROVYN 4' x 8' SHEETS DIRECT-GLUED TO WALL. COLOR: DRIFTWOOD #262 BREAK INDICATES SEAM; TO BE BUTT-JOINTED. TYP. 8' - 0"TYP.4' - 0"REF. "E" SERIES DRWGS FOR COORDINATION OF SWITCHES/CONTROLS. WHERE THERE IS A CONFLICT, WALL PROTECTION IS TO BE CUT-OUT TO ALLOW FORSWITCH/CONTROL. WALL TO RECEIVE RIGID WALL PROTECTION. BASIS- OF-DESIGN: ACROVYN 4' x 8' SHEETS DIRECT-GLUED TO WALL. COLOR: DRIFTWOOD #262 BREAK INDICATES SEAM; TO BE BUTT-JOINTED. TYP. 8' - 0"TYP.4' - 0"REF. "E" SERIES DRWGS FOR COORDINATION OF SWITCHES/CONTROLS. WHERE THERE IS A CONFLICT, WALL PROTECTION IS TO BE CUT-OUT TO ALLOW FORSWITCH/CONTROL. WALL TO RECEIVE RIGID WALL PROTECTION. BASIS- OF-DESIGN: ACROVYN 4' x 8' SHEETS DIRECT-GLUED TO WALL. COLOR: DRIFTWOOD #262 BREAK INDICATES SEAM; TO BE BUTT-JOINTED. TYP. 8' - 0"TYP.4' - 0"REF. "E" SERIES DRWGS FOR COORDINATION OF SWITCHES/CONTROLS. WHERE THERE IS A CONFLICT, WALL PROTECTION IS TO BE CUT-OUT TO ALLOW FORSWITCH/CONTROL. 2' - 6"1' - 6".3' - 0".1' - 0" 2' - 1" 1". 3". 2' - 0"2' - 7 3/4"3/4" WHITE MELAMINE ADJUSTABLE SHELF. COUNTERTOP W/ 4" BACKSPLASH. ALL EXPOSED SURFACES TO BE EPOXY. NOTES: 1. PLASTIC LAMINATE MILLWORK, TYPICAL. PROVIDE PLASTIC LAMINATE ON ALL EXPOSED SURFACES. INTERIORS TO BE WHITE MELAMINE. 2. PROVIDE WOOD BLOCKING AS REQUIRED. 3. PROVIDE SELF EDGE ALONG EXPOSED EDGES (FRONT AND SIDES) OF COUNTERTOP. 4. HARDWARE AS SELECTED. REFER TO CABINETRY ELEVATIONS. 5. SECTION SHOWN FOR REFERENCE ONLY. PROVIDE PLASTIC LAMINATE TOEKICK TO MATCH ALL ADJACENT CABINET FINISHES BASE CABINETRY. ALL EXPOSED SURFACES TO BE PLASTIC LAMINATE. FINISH FACE OF WALL 3/4" WHITE MELAMINE ADJUSTABLE SHELF. UPPER CABINETRY. ALL EXPOSED SURFACES TO BE PLASTIC LAMINATE. 6 INCH UTILITY CHASE.7' - 0"DOORS TO HAVE GLASS OR PLEXI-GLASS FRONTS. 2' - 1" 1". FULL-EXTENSION DRAWER GLIDES, TYP.3' - 0'.2' - 0" 3".0' - 4"COUNTERTOP W/ 4" BACKSPLASH. ALL EXPOSED SURFACES TO EPOXY. NOTES: 1. PLASTIC LAMINATE MILLWORK, TYPICAL. PROVIDE PLASTIC LAMINATE ON ALL EXPOSED SURFACES. INTERIORS TO BE WHITE MELAMINE. 2. PROVIDE WOOD BLOCKING AS REQUIRED. 3. PROVIDE SELF EDGE ALONG EXPOSED EDGES (FRONT AND SIDES) OF COUNTERTOP. 4. HARDWARE AS SELECTED. REFER TO CABINETRY ELEVATIONS. 5. SECTION SHOWN FOR REFERENCE ONLY. PROVIDE PLASTIC LAMINATE TOEKICK TO MATCH ALL ADJACENT CABINET FINISHES BASE CABINETRY. ALL EXPOSED SURFACES TO BE PLASTIC LAMINATE. FINISH FACE OF WALL 6 INCH UTILITY CHASE. N 123456 A B C D E 123456 A B C D E Project No. Project Date Produced These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect. KEY PLAN B A 5/22/2023 3:25:21 PMC:\_RevitLocal\2023-067.POR_Bldg001_A_2023\2023-067.POR_Bldg001_A_2023_kroche.rvt2023-067.POR 05.22.2023 INTERIOR ELEVATIONS & DETAILS I-201 KER Coram Deo Academy Phase One Renovations 2023-067.POR_Coram Deo Academy_Phase One Renovations_525 Congressional Blvd, Carmel, IN 46032 I-201_ INTERIOR ELEVATIONS & DETAILS1/4" = 1'-0"2C SCIENCE A121 - ELEVATION 1 1/4" = 1'-0"2E SCIENCE A121 - ELEVATION 2 1/4" = 1'-0"2A GYM A110 - SOUTH WALL ELEVATION CASEWORK: PL-1 COUNTERTOP: EPOXY 1/4" = 1'-0"2D SCIENCE A121 - VISUAL DISPLAY CASEWORK: PL-1 COUNTERTOP: EPOXY 1/4" = 1'-0"2B GYM A110 - TYP. WALL PROTECTION (WEST WALL) # Revision Date 1/4" = 1'-0"5C GYM A110 - NORTH WALL ELEVATION 1/4" = 1'-0"5B GYM A110 - EAST WALL ELEVATION 1/4" = 1'-0"5A GYM A110 - ANGLED WALL ELEVATION DIVERSIFIED WOODCRAFTS MODEL #4332K SHOWN FOR REFERENCE. 3/4" = 1'-0"4D TYPICAL CASEWORK - BASE 2 DR AND WALL CABINET 3/4" = 1'-0"5D TYPICAL CASEWORK - 4 DRAWER ABBREVIATIONS EDREQUIVALENT DIRECT RADIATION SA GALVGALVANIZED STP HWCFHEATING HOT WATER CHEMICAL FEED HHWR HWP HEATING HOT WATER RETURN HEATING HOT WATER PUMP STS STRUCT HPWS HPWP HSPF HRP HR HE HD HORIZ HP HPWR HEAT RECOVERY PUMP HEAT PUMP WATER SUPPLY HEAT PUMP WATER PUMP HOUR HEATING SEASONAL PERFORMANCE FACTOR HEAT PUMP WATER RETURN HEAT EXCHANGER HORSEPOWER/HEAT PUMP HORIZONTAL HEAD (FT.) GR GRV GS H GIV GC GPM GPH GLYCOL RETURN GLYCOL SUPPLY HUMIDITY/HUMIDIFIER GRAVITY RELIEF VENTILATOR GENERAL CONTRACTOR GALLONS PER MINUTE GALLONS PER HOUR GRAVITY INTAKE VENTILATOR STD ST SS SPEC SRV SHT SD SG SHR SECT SF SCC SF SAT PTS F&TFLOAT & THERMOSTATIC STEAM TRAP FIRE DAMPER FTR GAL GA FT FPM FTG FINNED TUBE RADIATION GALLON GAUGE FEET PER MINUTE FOOTING FOOT/FEET FLR FCP FD FCU FLOOR FLUID COOLER PUMP FAN COIL UNIT RV RS RP RPM RM RHG RL RG RHC RH RAT RECIR RES RF R RA R(#) ENTERING WATER TEMPERATURE (°F) EVAPORAT(E), (ING), (ED), (OR) EXTERNAL STATIC PRESSURE (IN WG) EX EXP F&B °F EUH EVAP ET EWT DEGREES FAHRENHEIT FACE AND BY-PASS EXPANSION EXISTING EXPANSION TANK ELECTRIC UNIT HEATER EMER ENCL EOM ESP EQUIP EF EFF ELEV ELEC EG EMERGENCY END OF MAIN DRIP EQUIPMENT ENCLOSURE EXHAUST GRILLE ELEVATION ELECTRIC EFFICIENCY EXHAUST FAN PSIG PT PRESS PSI PREFAB PPM PNEU PER (%) PHWR PHWS PI PHC PH PCHS PD PE PCHR SUPPLY AIR STORAGE TANK PUMP STORAGE TANK SUPPLY STRUCTURE(E), (AL) STORAGE TANK STAINLESS STEEL STANDARD SAFETY RELIEF VALVE SPECIFICATIONS SHEET STEAM CONDENSATE COOLER SUPPLY AIR TEMPERATURE (°F) SUPPLY DIFFUSER SENSIBLE HEAT RATIO SUPPLY GRILLE SQUARE FOOT SECTION SUPPLY FAN PNEUMATIC TUBE STATION RELATIVE HUMIDITY RADIANT PANEL (CEILING-MOUNTED) REVOLUTIONS PER MINUTE REFRIGERANT SUCTION REFRIGERANT VENT RELATIVE HUMIDITY REFRIGERANT HOT GAS REFRIGERANT LIQUID REHEAT COIL RETURN GRILLE ROOM RECIRCULAT(E), (OR), (ING) RETURN AIR TEMPERATURE (°F) RETURN FAN THERMAL RESISTANCE REFRIGERANT (NUMBER) RETURN AIR POUNDS PER SQUARE INCH POUNDS PER SQUARE INCH GAUGE PNEUMATIC TUBE PRESSURE PARTS PER MILLION PREFABRICATED PNEUMATIC PANEL CHILLED WATER SUPPLY PERIMETER HEATING HOT WATER RETURN PERIMETER HEATING HOT WATER SUPPLY PRESSURE DROP (IN OR WG AS NOTED) PANEL CHILLED WATER RETURN PERCENT PRESSURE INDICATOR PREHEAT COIL PHASE PNEUMATIC-ELECTRIC BFWBOILER FEED WATER MISC CONVCONVECTOR ENTERING AIR TEMPERATURE (°F) CONDENSER WATER CHEMICAL FEED CLASSROOM UNIT VENTILATOR EA EAT EC DN DWG ELECTRICAL CONTRACTOR EXHAUST AIR DRAWING DOWN CWP CWCF D DB CP CT CV CUV CUH CONDENSER WATER PUMP DRAIN BOX DRAIN CONTROL VALVE COOLING TOWER CABINET UNIT HEATER CONDENSATE PUMP P PBD OFOI OFCI OBD OA OAT NA NO NTS NIC NC MV MTD CONTRACTOR FURNISHED/OWNER INSTALLED CHILLED WATER RETURN CHILLED WATER CHEMICAL FEED BRITISH THERMAL UNIT PER HOUR CO CI CONN CHWR CF CFM CFOI CH CHCF CHP CONNECTION CAST IRON CLEANOUT CHILLED WATER PUMP CUBIC FEET PER MINUTE CHILLER CUBIC FEET CD BTUH CAB CAV BHP BFWP BOD BOP BLDG CONSTANT AIR VOLUME CONDENSATE DRAIN CABINET BOTTOM OF PIPING BOTTOM OF DUCT BRAKE HORSEPOWER BOILER FEED WATER PUMP BUILDING MIN MECH MD MCC MC MBH MAT LWT LPS LFC LFD LP LEC LD ACCESS DOOR ("M" DWGS). AREA DRAIN ("P" DWGS) AIR COOLED CONDENSING UNIT AMPERE (AMP, AMPS) BBD BFC BDD AMP ARCH AS AV APD APPROX BOILER BLOW DOWN BACKDRAFT DAMPER BELOW FINISHED CEILING AIR PRESSURE DROP (IN WG) ARCHITECT (URAL) APPROXIMAT(E), (LY) AIR SEPARATOR AUTOMATIC VENT ADJ AFF AHU ALTER AFM ACCU ACU AD ADA AAF ADJUSTABLE AIR FLOW MONITORING ABOVE FINISHED FLOOR AIR HANDLING UNIT ALTERNATE AIR CONDITIONING UNIT AUTOMATIC AIR VENT AMERICAN DISABILITIES ACTLBS LAT LAF LAD LAB KW KEC IN INDIC INSUL INT INCIN INCL IB ID HHWS HZ UVUNIT VENTILATOR VARIABLE FREQUENCY DRIVE W/OWITHOUT MISCELLANEOUS OWNER FURNISHED/CONTRACTOR INSTALLED OWNER FURNISHED/OWNER INSTALLED OUTSIDE AIR TEMPERATURE (°F) PARALLEL BLADE DAMPER PUMP OPPOSED BLADE DAMPER OUTSIDE AIR NOT APPLICABLE NORMALLY CLOSED NORMALLY OPEN NOT TO SCALE NOT IN CONTRACT MANUAL VENT MOUNTED ZN WTR WPD ZONE WATER PRESSURE DROP WATER MIXED AIR TEMPERATURE (°F) THOUSANDS OF BTU PER HOUR MOTOR CONTROL CENTER MOTORIZED DAMPER MECHANICAL MINIMUM MECHANICAL CONTRACTOR MAXIMUM LABORATORY FURNISHINGS CONTRACTOR LOW PRESSURE STEAM LEAVING WATER TEMPERATURE (°F) LABORATORY EQUIPMENT CONTRACTOR LAMINAR FLOW DIFFUSER LIQUID PETROLEUM LINEAR DIFFUSER WG W/ WATER GAUGE WITH VB VERT VFD VIF VC VD VAC VAR VAV VA VACUUM BREAKER VOLUME DAMPER VERIFY IN FIELD VACUUM CLEANING VERTICAL VOLT AMPERE VARIABLE AIR VOLUME VACUUM VARIABLE TEMPERATURE CONTROL CONTRACTOR TEMPERATURE DIFFERENCE TOTAL STATIC PRESSURE (IN WG) UNLESS NOTED OTHERWISE HEAT TRANSFER COEFFICIENT LEAVING AIR TEMPERATURE (°F) KITCHEN EQUIPMENT CONTRACTOR LAMINAR AIR FLOW LAMINAR AIR DIFFUSER LABORATORY POUND KILOWATT HEATING HOT WATER SUPPLY INVERTED BUCKET STEAM TRAP INCH/INCHES INSULAT(E), (ED), (ION) INCLUD(E), (ED) INCINERATOR INDICATOR INTERIOR FREQUENCY (MEGAHERTZ) INSIDE DIAMETER UNO UC UH U TYP. TSTAT TSP UNIT HEATER UNDER CUT THERMOSTAT TYPICAL TC TEMP TONS TCC TD SV TB SUCT TEMPERATURE CONTROL TONS OF REFRIGERATION TEMPERATURE STEAM VENT TERMINAL BOX SUCTION CWRCONDENSER WATER RETURN CWSCONDENSER WATER SUPPLY COPCOEFFICIENT OF PERFORMANCE CHILLED WATER SUPPLYCHWS EERENERGY EFFICIENCY RATIO SEERSEASONAL ENERGY EFFICIENCY RATIO HTRHEATER MAX STRSTORAGE TANK RETURN VRVVARIABLE REFRIGERANT VOLUME BRANCH SELECTOR BOXBSB ABBREVIATIONS CCOMMON LPCLOW PRESSURE CONDENSATE MPCMEDIUM PRESSURE CONDENSATE MPSMEDIUM PRESSURE STEAM HPSHIGH PRESSURE STEAM HPCHIGH PRESSURE CONDENSATE GFSGLYCOL FILL STATION 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. 32. 33. 34. 35. 36. 37. 38. 39. 40. 41. 42. 43. 44. 45. 46. 47. THESE GENERAL NOTES APPLY TO M-SERIES DRAWINGS. ADDITIONAL GENERAL NOTES SPECIFIC TO A PARTICULAR DRAWING ARE NOTED ON THOSE SHEETS. IT IS THE INTENT OF THESE DOCUMENTS TO PROVIDE MECHANICAL SYSTEMS THAT ARE FULLY FUNCTIONAL. PROVIDE ALL ITEMS SPECIFIED AND REQUIRED FOR COMPLETE OPERATIONAL SYSTEMS. ON MECHANICAL "M" SERIES DRAWINGS, DARK LINE ITEMS INDICATE NEW WORK. LIGHT LINE ITEMS ARE ITEMS THAT SHALL REMAIN. THESE DRAWINGS INDICATE REQUIRED SIZE AND POINTS OF TERMINATION FOR PIPING, DUCTWORK, CONDUIT, ETC. THE EQUIPMENT SHOWN ILLUSTRATES SUGGESTED ROUTING, BUT ALL NECESSARY OFFSETS MAY NOT BE SHOWN. DIVISION 23 SHALL INSTALL HIS WORK IN A MANNER THAT WILL CONFORM WITH THE STRUCTURE. DIVISION 23 SHALL AVOID OBSTRUCTIONS, PRESERVE HEADROOM AND MAINTAIN MAXIMUM CLEARANCE WITHOUT FURTHER INSTRUCTION FROM THE ARCHITECT/ENGINEER OR ADDITIONAL COST TO THE OWNER. ALL DUCTWORK, PIPING, AND VALVES SHALL BE CONCEALED ABOVE CEILING AND WITHIN WALLS IN FINISHED AREAS UNLESS OTHERWISE INDICATED. ALL VALVES, ETC. SHALL BE INSTALLED ALLOWING EASY ACCESS BETWEEN LIGHT FIXTURES AND NO HIGHER THAN 12" TO 24" ABOVE THE CEILING. PROVIDE FITTINGS IN DUCTWORK AND PIPING AS REQUIRED SO THAT NO PIPING REMAINS TIGHT TO ROOF STRUCTURE. PROVIDE ACCESS PANELS AS REQUIRED. AREA ADJACENT TO THE ACCESS PANELS SHALL BE CLEAR OF ANY OBSTRUCTIONS. PROVIDE EXTENDED VALVE HANDLES FOR INSULATED PIPING. DIVISION 23 SHALL BE GUIDED BY THE ARCHITECT/ENGINEER'S REFLECTED CEILING PLAN FOR LOCATION OF DIFFUSERS, REGISTERS, GRILLES SHOWN OR COVERED BY THESE PLANS. RETURN GRILLES SHALL NOT ALIGN WITH SUPPLY AIR THROW. CONTRACTOR SHALL COORDINATE EXACT LOCATION OF ALL GRILLES, REGISTERS AND DIFFUSERS IN CEILINGS WITH THE CEILING SYSTEM AND LIGHT FIXTURES. PROVIDE FLEXIBLE DUCT UPSTREAM OF EACH DIFFUSER WHERE SHOWN. ARROWS ON THE HOT WATER COLD WATER MAINS INDICATE THE DIRECTION OF FLOW. PITCH MAINS UPWARD A MINIMUM OF 1" PER 60' IN THE DIRECTION OF FLOW. ARROWS ON STEAM AND CONDENSATE PIPING AND DRAIN LINE INDICATE THE DOWNWARD PITCH OF THE PIPING. INSTALL AIR VENTS AT ALL HIGH POINTS AND DRAINS AT ALL LOW POINTS OF WATER PIPING SYSTEMS. DRAINS TO HAVE HOSE END THREADS WITH CLEARANCE TO ATTACH HOSE. PIPING BRANCHES TO EQUIPMENT SHALL HAVE SAME SIZE VALVES AND FITTINGS AS THAT OF THE LINE SIZE WITH THE EXCEPTION OF THE TEMPERATURE CONTROL VALVES. PIPE "SWING" CONNECTIONS WITH UNIONS OR FLANGES SHALL BE MADE EXTERNAL TO COILS OR A TUBE BUNDLE TO FACILITATE REMOVAL OF THAT ITEM WITHOUT DISTURBING THE BRANCH VALVES AND/OR PIPING. DUCT AND PIPING PENETRATING FLOOR SLABS AND/OR WALLS SHALL BE SEALED WITH ACOUSTIC SEALANT. IF THE FLOOR OR WALL IS FIRE RATED PROVIDE THE FIRE STOPPING OR FIRE DAMPER TO MAINTAIN THE FIRE RATING. ALL RECTANGULAR SHEET METAL DUCT SIZES ARE INSIDE DIMENSIONS. ALL ROUND DUCT SIZES SHOWN ARE INSIDE DIAMETERS. ALLOWANCE FOR ACOUSTICAL LINER WHERE INDICATED ON DRAWINGS MUST BE ADDED TO OBTAIN OUTSIDE SHEET METAL DIMENSION. ALL WALL THERMOSTATS, TEMPERATURE SENSORS, AND/OR HUMIDISTATS SHALL BE APPROXIMATELY 46" ABOVE FINISHED FLOOR TO CENTER AND LINED UP HORIZONTALLY WITH LIGHT SWITCHES UNLESS OTHERWISE NOTED OR DIRECTED BY THE ARCHITECT/ENGINEER. DIVISION 23 CONTRACTOR SHALL BE RESPONSIBLE FOR HIS RESPECTIVE WORK FOR REPAIRING AND PATCHING TO MATCH EXISTING SURFACES, SIDEWALKS, STREETS, FLOORS, WALLS, ROOFS, CEILING AND PAVEMENT. CONTRACTOR SHALL INCLUDE IN BID PROPOSAL ALL COSTS FOR CUTTING AND PATCHING REQUIRED TO INSTALL NEW OR REMOVE EXISTING WORK, EQUIPMENT, OR SYSTEMS. DIVISION 23 CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ALL OF HIS WORK TO BE INSTALLED WITH ANY AND ALL OTHER CONTRACTORS TO BE AFFECTED BY SUCH WORK, PRIOR TO ORDERING ANY OF THE EQUIPMENT. THIS SHALL INCLUDE BUT NOT LIMITED TO ELECTRICAL CHARACTERISTICS, CONNECTIONS REQUIRED, PHYSICAL SIZE, COLOR AND FIT. ALSO REFER TO SPECIFICATIONS. ALL EQUIPMENT SHALL BE OF, AND CONSIST OF, AT LEAST MINIMUM SIZES SELECTED, AND SHALL PERFORM TO OR SURPASS THE MINIMUM REQUIREMENTS, SCHEDULES, NOTED AND SPECIFIED. COORDINATE INSTALLATION OF NEW WORK WITH ALL OTHER TRADES AND EXISTING CONDITIONS AS REQUIRED FOR A COMPLETE AND OPERABLE HVAC SYSTEM. CLEARANCES ABOVE CEILINGS ARE EXTREMELY TIGHT IN CERTAIN AREAS. RELOCATE PIPING, ELECTRIC CONDUIT, STRUCTURAL BRACING, ETC., AS REQUIRED FOR A COMPLETE INSTALLATION OF HVAC WORK. COORDINATE ROUTING OF NEW DUCTWORK ABOVE CEILINGS WITH EXISTING ELECTRIC CABLE TRAY. M.C. TO COORDINATE ALL DUCTWORK ROUTING AND DUCTWORK ELEVATIONS WITH STRUCTURAL STEEL SUPPORTS FOR FOLDING WALLS. REFERENCE STRUCTURAL DRAWINGS FOR SIZE AND LOCATIONS OF STEEL. FIELD VERIFY ALL EXISTING CONDITIONS. CONTRACTOR SHALL COORDINATE EXACT LOCATION OF ALL VAV REHEAT BOXES AND DUCTWORK WITH THE CEILING SYSTEM AND LIGHT FIXTURES. FIELD VERIFY EXISTING CEILING SYSTEMS AND LOCATION OF EXISTING LIGHT FIXTURES. ALLOW REQUIRED CLEARANCES FOR SERVICE TO BOX AND CONTROLS. CONTRACTOR SHALL RELOCATE EXISTING LIGHT FIXTURE AND CEILING GRID SUPPORT HANGERS AS REQUIRED FOR INSTALLATION OF NEW VAV REHEAT BOXES, DUCTWORK AND PIPING. PROVIDE VOLUME DAMPERS IN ALL SUPPLY AIR BRANCH DUCTWORK AS REQUIRED TO BALANCE EACH SYSTEM. ALL VOLUME DAMPERS LOCATED ABOVE DRYWALL CEILINGS SHALL BE CABLE OPERATED WITH REMOTE REGULATOR LIKE YOUNG REGULATOR. FIELD VERIFY EXISTING CEILINGS FOR DRYWALL CEILINGS. COORDINATE LOCATION OF ALL DAMPERS WITH AIR BALANCE CONTRACTOR. IN HARD CEILINGS PROVIDE VOLUME DAMPER BEHIND THE GRILLE, REGISTER, OR DIFFUSER. PROVIDE 45°/90° FITTING WITH VOLUME DAMPER LIKE FLEXMASTER MODEL STO AT ALL SUPPLY AIR AND PRIMARY AIR BRANCH DUCTWORK TAKEOFFS. CONTRACTOR SHALL REVIEW RETURN AIR PATH BACK TO ALL HVAC EQUIPMENT. PROVIDE RETURN AIR OPENINGS AND/OR JUMPER DUCTS IN WALLS ABOVE THE CEILING WHERE REQUIRED. COORDINATE WITH GENERAL TRADES. VELOCITY THRU R.A. OPENINGS SHALL NOT EXCEED 500 FPM. FIELD VERIFY LOCATION OF EXISTING WALLS EXTENDING TO DECK. ALL TRANSFER AIR DUCTS TO BE INTERNALLY INSULATED TO DETER NOISE TRANSFER. SIZE SHOWN ON PLANS INDICATES ACTUAL FREE AREA. ALL NEW PIPING AND DUCTWORK CROSSING THRU EXISTING CORRIDOR AND/OR CLASSROOM WALLS TO DECK; CUT WALLS AS REQUIRED. COORDINATE ALL OPENINGS THROUGH EXISTING WALL CONSTRUCTION WITH GENERAL TRADES. SEAL AROUND DUCTWORK AND PIPING TO HELP REDUCE THE TRANSFER OF NOISE BETWEEN CLASSROOMS. FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING OF BID. ROUND DUCT SIZE TO BE THE SAME SIZE AS THE DIFFUSER NECK; UNLESS OTHERWISE NOTED. MAXIMUM LENGTH OF FLEXIBLE DUCTWORK CONNECTED TO A DIFFUSER SHALL BE 5'-0". ALL DUCTWORK CONSTRUCTION SHALL BE FABRICATED SHEET METAL & BUILT IN ACCORDANCE WITH "SMACNA" STANDARDS. ALL SUPPLY, RETURN, RELIEF/EXHAUST, AND OUTDOOR AIR DUCTWORK SHALL BE EXTERNALLY INSULATED. SEE SPECIFICATION FOR ADDITIONAL INSULATION REQUIREMENTS. ALL ROUND DUCT TO BE EXTERNALLY INSULATED UNLESS NOTED OTHERWISE. SIZE SHOWN INDICATES ACTUAL DUCT FREE AREA. SEE SPECIFICATION FOR ADDITIONAL INSULATION REQUIREMENTS. ALL NEW ROOF WORK TO BE IN ACCORDANCE WITH OWNER'S EXISTING ROOF WARRANTY. ALL ROOF PENETRATIONS TO BE SEALED WATER TIGHT. PACK VOID BETWEEN DUCT PENETRATING ROOF AND STRUCTURE WITH FIBERGLASS INSULATION AND CAULK WATER TIGHT. FOR HIGH TEMPERATURE OR GREASE DUCTS UTILIZE MINERAL WOOL. TEMPERATURE CONTROL CONTRACTOR SHALL PROVIDE ALL CONTROL WIRING COMPLETE FOR THIS PROJECT. ALL WIRING (AND INTERLOCK WIRING) TO THERMOSTATS, SPACE SENSORS, HUMIDISTATS, CARBON DIOXIDE MONITORS, ETC. ARE TO BE CONCEALED WITHIN THE WALL. ALL HARD 90° ELBOWS IN SUPPLY DUCTWORK ARE TO HAVE TURNING VANES PER SPECIFICATION AIR DUCT ACCESSORIES. REMOVE ALL WORK MADE OBSOLETE BY NEW CONSTRUCTION. DEMOLITION OF EXISTING MECHANICAL EQUIPMENT TO INCLUDE ASSOCIATED PIPING AND DUCTWORK NECESSARY FOR NEW EQUIPMENT INSTALLATION. ALL EXISTING TO REMAIN AND NEW PVC PLUMBING VENT LINES LOCATED ABOVE CEILING IN RETURN PLENUM ARE TO BE EXTERNALLY WRAPPED WITH FLAME AND SMOKE SPREAD RATED INSULATION MATERIAL AS REQUIRED. REFERENCE SECTION DIVISION 01 "SUMMARY" [MULTIPLE CONTRACT SUMMARY] FOR CONSTRUCTION PHASING. CONTRACTOR SHALL THOROUGHLY EXAMINE THE CONTRACT DOCUMENTS, INCLUDING THE WORK OF OTHER CONTRACTORS PRIOR TO SUBMITTING A BID PROPOSAL. ALL EXHAUST FANS, RELIEF VENTS, FLUES, AND PLUMBING VENTS TO BE INSTALLED A MINIMUM OF 10 FT. FROM OUTDOOR AIR INTAKES. CONTRACTOR SHALL CLEAN ALL OF HIS WORK INSIDE AND OUT. AIR DISTRIBUTION SYSTEMS SHALL HAVE ALL DIRT AND FOREIGN MATERIAL REMOVED FROM INSIDE AND OUTSIDE OF DUCTS, PLENUMS, HOUSINGS, DEVICES, TERMINALS, ETC. AS INSTALLATION PROGRESSES, PROTECT OPEN ENDS OF DUCTWORK AND INLETS AND OUTLETS OF EQUIPMENT AND DEVICES DURING CONSTRUCTION. CLEAN ALL ACCESSIBLE PARTS OF DUCTWORK AND AIR PASSAGES IN EQUIPMENT BEFORE FILTERS ARE INSTALLED OR REPLACED FOR SYSTEM BALANCING. FURNISH AND INSTALL ACCEPTABLE CONCRETE INSERTS, ANCHORS, CLAMPS, BRACKETS, HANGERS, STRUCTURAL MEMBERS (ANGLES, CHANNELS, ETC.) AND FRAMES, ETC., REQUIRED FOR SUPPORTING ALL RESPECTIVE WORK. SUPPORTING DEVICES, ASSEMBLIES AND ATTATCHMENTS SHALL BE DESIGNED AND ARRANGED TO CARRY THE WEIGHT OF THE SUPPORTED ITEMS INCLUDING HANGER AND CONTENTS WITHOUT TRANSMITTING VIBRATION OR NOISE TO THE BUILDING CONSTRUCTION; DESIGNED, APPROPRIATE AND APPROVED FOR THE PURPOSE USED; HAVE A NEAT AND FINISHED APPEARANCE AND COMPLEMENT THE INSTALLATION; HAVE CORROSION PROTECTION SUITABLE FOR THE ATMOSPHERE WHERE INSTALLED; ADEQUATELY AND SAFELY ATTACHED TO THE BUILDING STRUCTURE OR STRUCTURAL MEMBERS. EXPOSED SUPPORTS SHALL BE PAINTED UNLESS OF NON-FERROUS MATERIAL OR PROVIDED WITH PLATED (RUSTPROOF) FINISH. PROVIDE NEC CLEARANCES AND SERVICE CLEARANCES FOR EQUIPMENT. COORDINATE EQUIPMENT SERVICE ACCESS. CLEARANCES INDICATED ARE BASED UPON BEST AVAILABLE INFORMATION. CONTRACTOR SHALL VERIFY PIPING, DUCTWORK, ETC., ROUTING PRIOR TO SUBMITTING A BID PROPOSAL AND INCLUDE ANY SUCH COSTS AS REQUIRED TO INSTALL WORK AS SHOWN AND INTENDED. EXISTING VALVES MADE INACCESSIBLE BY NEW DUCT AND/OR PIPING SHALL BE RELOCATED AS REQUIRED FOR ACCESS. DURING REMOVAL OF ITEMS, CAUTION SHALL BE USED TO PREVENT DAMAGE TO ANY EQUIPMENT HAVING SALVAGE VALUE. ALL REUSABLE SALVAGED MATERIAL SHALL REMAIN THE PROPERTY OF THE OWNER AND BE RETAINED FOR HIS INSPECTION. ONLY ITEMS SO INSPECTED AND REJECTED BY THE OWNER SHALL BE DISPOSED OF BY THE CONTRACTOR. ALL OTHER ITEMS SHALL BE TURNED OVER AND DEPOSITED AS DIRECTED BY THE OWNER. CONTRACT DOCUMENTS CONSIST OF BOTH PROJECT MANUAL AND DRAWINGS AND BOTH ARE MEANT TO BE COMPLEMENTARY - ANYTHING APPEARING ON EITHER MUST BE EXECUTED THE SAME AS IF SHOWN ON BOTH. VERIFY EXACT SIZE AND LOCATION OF ALL EXISTING PIPING AND DUCTWORK PRIOR TO CONSTRUCTION OR BIDDING. GENERAL NOTES CO2 EQUIPMENT SYMBOLS SUPPLY DIFFUSER W/TYPE AND CFM(ONE-WAY SIDE TYPE) LINEAR DIFFUSER W/TYPE AND CFM(TWO-WAY SIDE TYPE) SUPPLY DIFFUSER W/TYPE AND CFM(THREE-WAY TYPE) SIDEWALL GRILLE W/TYPE AND CFM RETURN GRILLE W/ TYPE AND CFM SUPPLY DIFFUSER W/TYPE AND CFM (FOUR-WAY TYPE) SUPPLY DIFFUSER W/TYPE AND CFM(TWO-WAY SIDE TYPE) ROOF-MOUNTED EXHAUST FAN CEILING-MOUNTED EXHAUST FAN CARBON DIOXIDE SENSOR AT ROOF AT CEILING EXHAUST GRILLE W/ TYPE AND CFM H HUMIDITY SENSOR T THERMOSTAT F&T GENERAL DUTY VALVES & FITTINGS EXPANSION LOOP (SIZE INDICATEDON DRAWINGS) CONCENTRIC REDUCER ECCENTRIC REDUCER PRESSURE REDUCING VALVE STEAM TRAP W/DESIGNATION GAS COCK PETE'S PLUG PIPE EXPANSION JOINT FLEXIBLE PIPING CONNECTOR Y-STRAINER W/BLOWDOWNVALVE & CAP PIPE ANCHORS PIPE GUIDES THERMOMETER WELL AUTOMATIC AIR VENT GAUGE CONNECTION(S) & WELL THERMOMETER & WELL MANUAL AIR VENT AUTOMATIC BALANCING VALVE TWO-WAY CONTROL VALVE THREE-WAY CONTROL VALVE UNION MANUAL BALANCING VALVE VALVE IN RISER ANGLE VALVE PLUG VALVE TRIPLE DUTY VALVE PRESSURE REGULATING VALVE BUTTERFLY VALVE RELIEF VALVE VALVE - SEE SPECIFICATIONSFOR VALVE TYPE PIPE CONTINUED ON ANOTHERDRAWING CHECK VALVE CAPPED PIPE RISE IN PIPING DROP IN PIPING GATE VALVE BALL VALVE DUCTWORK SYSTEMS EXHAUST AIR EXHAUST/RELIEF AIR KITCHEN EXHAUST AIR OUTSIDE AIR RELIEF AIR RETURN AIR SUPPLY AIR TRANSFER AIR EA EA/RL KEA OA RLA RA SA TA CHILLED WATER RETURN CHILLED WATER SUPPLY CONDENSATE DRAIN CONDENSER WATER RETURN CONDENSER WATER SUPPLY HEAT PUMP RETURN HEAT PUMP SUPPLY HEATING HOT WATER RETURN HEATING HOT WATER SUPPLY HIGH PRESSURE STEAM RETURN HIGH PRESSURE STEAM SUPPLY LOW PRESSURE STEAM RETURN LOW PRESSURE STEAM SUPPLY MEDIUM PRESSURE STEAM RETURN MEDIUM PRESSURE STEAM SUPPLY REFRIGERANT RETURN REFRIGERANT SUPPLY REFRIGERANT SUCTION GAS RETURN STEAM CONDENSATE PUMP DISCHARGE STEAM VENT CHWR CHWS CD CWR CWS HPR HPS HHWR HHWS HPSR HPSS LPSR LPSS MPSR MPSS RR RS RSGR CPD SV PIPING SYSTEMS DUCTWORK SYMBOLS MANUAL VOLUME DAMPER SHOETAP (OR 45° ENTRY) FITTING BELLMOUTH FITTING 45° LATERAL FITTING 90° TEE FITTING SHOETAP WITH SQUARE TO ROUND TRANSITION DUCT TRANSITION CONICAL FITTING 90° ELBOW WITH TURNING VANES STANDARD RADIUS ELBOW, CENTER RADIUS INSULATED FLEXIBLE DUCTWORK OFFSET IN DUCTWORK (R = RISE D = DROP) RECTANGULAR DUCTWORK ROUND SPIRAL DUCTWORK OVAL DUCTWORK DROP IN DUCTWORK (EXHAUST, RETURN, ETC.) RISE IN DUCTWORK (EXHAUST, RETURN, ETC.) RISE IN DUCTWORK (SUPPLY ONLY) DROP IN DUCTWORK (SUPPLY ONLY) 1-1/2 TIMES WIDTH OF DUCT 12"x8"ϴ 12"Ø 12"x8" R D BLADE DAMPER PBD = PARALLEL BLADE DAMPER DUCT-MOUNTED REHEAT COIL (HYDRONIC) NEW TO EXISTING INTERNALLY INSULATED DUCTWORK FLEXIBLE CONNECTION ACCESS DOOR MOTORIZED CONTROL DAMPER BDD = BACKDRAFT DAMPER OBD = OPPOSED AIR FLOW 20°30° M AD BDD COUNTERBALANCED BACKDRAFT DAMPERBDD AD MOTORIZED BACKDRAFT DAMPERMBDD FD-(A/B) AD FSD AD SD AD FD-(A/B) = FIRE DAMPER (TYPE A OR TYPE B) FSD = FIRE/SMOKE DAMPER SD = SMOKE DAMPER 2M-301 3 M-501 SECTION REFERENCE DETAIL REFERENCE PLAN NOTE DRAWING NOTATIONS NOTE: ALL SYMBOLS AND ABBREVIATIONS MAY NOT BE USED FOR THIS PROJECT 11DEMO NEW NEW TO EXISTING DEMO TO THIS POINT EQUIPMENT TAG - (SEE SCHEDULE SHEETS) DIFFUSER, REGISTER, GRILLE TAG - (SEE SCHEDULE SHEETS)SD24-12300 XXX-1 CFMMARK N 123456 A B C D E 123456 A B C D E Project No. Project Date Produced These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect. KEY PLAN B A 5/22/2023 12:48:28 PMC:\_RevitLocal\2023-067.POR_Bldg001_M_2023\2023-067.POR_Bldg001_M_2023_tkennedy.rvt2023-067.POR 05.22.2023 MECHANICAL SYMBOLSAND ABBREVIATIONS M-001 Designer Author Coram Deo Academy Phase One Renovations 2023-067.POR_Coram Deo Academy_Phase One Renovations_525 Congressional Blvd,Carmel, IN 46032 M-001_ MECHANICAL SYMBOLS AND ABBREVIATIONS#Revision Date T6785 9 C D E 10 11 12 H J K L F G E.P 3 SD24-12 SD24-12 SD24-12 SD24-12 EC24/12 EC24/24 EC24/12 SD24-8 SD24-8 SD24-8 EC24/121 1 1 1 1 1 1 1 1EC24/12 1 1 1 18"x12" SA 12"x8" SA 1 A. B. C. DARK DASHED LINES INDICATE EXISTING MECHANICAL EQUIPMENT, DUCTWORK, PIPING, AND/OR MECHANICAL ACCESSORIES DEMOLISHED COMPLETE. CONTRACTOR TO FIELD VERIFY ACTUAL EXISTING CONDITIONS PRIOR TO BIDDING AND DEMOLITION. CONTRACTOR TO INCLUDE ALL COST TO REMOVE ITEMS MADE OBSOLETE DUE TO NEW HVAC WORK. CONTRACTOR GIVES OWNER FIRST RIGHTS OF REFUSAL ON ANY EXISTING EQUIPMENT THE OWNER MAY WANT TO KEEP. IF OWNER DECIDES SAID ITEM IS TO BE REMOVED, THEN CONTRACTOR IS TO REMOVE FROM PROJECT SITE AS REQUIRED. LIGHT SOLID LINES INDICATE EXISTING MECHANICAL EQUIPMENT, DUCTWORK, PIPING, AND/OR MECHANICAL ACCESSORIES TO REMAIN AS-IS. CONTRACTOR TO FIELD VERIFY ACTUAL EXISTING CONDITIONS PRIOR TO DEMOLITION AND BIDDING. GENERAL DEMOLITION NOTES N 123456 A B C D E 123456 A B C D E Project No. Project Date Produced These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect. KEY PLAN B A 5/22/2023 12:48:30 PMC:\_RevitLocal\2023-067.POR_Bldg001_M_2023\2023-067.POR_Bldg001_M_2023_tkennedy.rvt2023-067.POR 05.22.2023 FIRST FLOORDEMOLITION PLAN - UNITA MD1A1 Designer Author Coram Deo Academy Phase One Renovations 2023-067.POR_Coram Deo Academy_Phase One Renovations_525 Congressional Blvd,Carmel, IN 46032 MD1A1_ FIRST FLOOR DEMOLITION PLAN - UNIT A 1/8" = 1'-0"1ALevel 1 - MECHANICAL DEMOLITION PLAN - UNIT A DEMOLITION HVAC PLAN #NOTE 1 BASE AND ALTERNATE BID: REMOVE AIR TERMINAL AND ASSOCIATED FLEXIBLE DUCTWORK,INSPECT, PAINT, AND REPAIR AIR TERMINAL AS NECESSARY. RETAIN AIR TERMINAL FORREINSTALLATION. 1 BASE BID: INSPECTAND REPAIR DIFFUSERS AS NECESSARY. PROTECT DIFFUSERS THOUGHOUTCONSTRUCTION. 2 REMOVE AIR TERMINAL AND ASSOCIATED FLEXIBLE DUCTWORK TO CONNECTION AT SHEETMETALDUCT. RETAIN AIR TERMINAL FOR REINSTALLATION. PAINT AND REPAIR AS NECESSARY, REPLACE ASREQUIRED. 3 REMOVE THERMOSTAT FROM WALL. COORDINATE WITH ARCHITECTURE AND INTERIORS PLANS TODETERMINE IF PATCH AND REPAIR IS NECESSARY. 4 MECHANICAL CONTRACTOR TO CONDUCT AIRFLOW TEST FOR EXISTING AIRFLOW RATE PRIOR TODEMOLITION. 5 REMOVE AIR TERMINAL COMPLETE, REMOVE AND CAP EXISTING DUCTWORK AT NORTH WALL. 6 PROTECT THERMOSTAT DURING CONSTRUCTION. #Revision Date TTTTT 5 A 21 B C D G A5A4A3A2A1 E.P 3 5 6 1 6 3 2 2 2 SD24-10 SD24-10 SD24-10 SD24-10 SD24-10 SD24-10 SD24-10SD24-10 SD24-10 SD24-10 SD24-10 SD24-10 SD24-10 2 22 2 2 2 2 2 2222 EC24/24 2 SD24-12 SD24-12 EC24/24 5 EC24/122 SD24-12 SD24-12 3 2 2 SD24-10 SD24-10 A. B. C. DARK DASHED LINES INDICATE EXISTING MECHANICAL EQUIPMENT, DUCTWORK, PIPING, AND/OR MECHANICAL ACCESSORIES DEMOLISHED COMPLETE. CONTRACTOR TO FIELD VERIFY ACTUAL EXISTING CONDITIONS PRIOR TO BIDDING AND DEMOLITION. CONTRACTOR TO INCLUDE ALL COST TO REMOVE ITEMS MADE OBSOLETE DUE TO NEW HVAC WORK. CONTRACTOR GIVES OWNER FIRST RIGHTS OF REFUSAL ON ANY EXISTING EQUIPMENT THE OWNER MAY WANT TO KEEP. IF OWNER DECIDES SAID ITEM IS TO BE REMOVED, THEN CONTRACTOR IS TO REMOVE FROM PROJECT SITE AS REQUIRED. LIGHT SOLID LINES INDICATE EXISTING MECHANICAL EQUIPMENT, DUCTWORK, PIPING, AND/OR MECHANICAL ACCESSORIES TO REMAIN AS-IS. CONTRACTOR TO FIELD VERIFY ACTUAL EXISTING CONDITIONS PRIOR TO DEMOLITION AND BIDDING. GENERAL DEMOLITION NOTES N 123456 A B C D E 123456 A B C D E Project No. Project Date Produced These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect. KEY PLAN B A 5/22/2023 12:48:32 PMC:\_RevitLocal\2023-067.POR_Bldg001_M_2023\2023-067.POR_Bldg001_M_2023_tkennedy.rvt2023-067.POR 05.22.2023 FIRST FLOORDEMOLITION PLAN - UNITB MD1B1 Designer Author Coram Deo Academy Phase One Renovations 2023-067.POR_Coram Deo Academy_Phase One Renovations_525 Congressional Blvd,Carmel, IN 46032 MD1B1_ FIRST FLOOR DEMOLITION PLAN - UNIT B 1/8" = 1'-0"1ALevel 1 - MECHANICAL DEMOLITION PLAN - UNIT B DEMOLITION HVAC PLAN #NOTE 1 BASE AND ALTERNATE BID: REMOVE AIR TERMINAL AND ASSOCIATED FLEXIBLE DUCTWORK,INSPECT, PAINT, AND REPAIR AIR TERMINAL AS NECESSARY. RETAIN AIR TERMINAL FORREINSTALLATION. 1 BASE BID: INSPECTAND REPAIR DIFFUSERS AS NECESSARY. PROTECT DIFFUSERS THOUGHOUTCONSTRUCTION. 2 REMOVE AIR TERMINAL AND ASSOCIATED FLEXIBLE DUCTWORK TO CONNECTION AT SHEETMETALDUCT. RETAIN AIR TERMINAL FOR REINSTALLATION. PAINT AND REPAIR AS NECESSARY, REPLACE ASREQUIRED. 3 REMOVE THERMOSTAT FROM WALL. COORDINATE WITH ARCHITECTURE AND INTERIORS PLANS TODETERMINE IF PATCH AND REPAIR IS NECESSARY. 4 MECHANICAL CONTRACTOR TO CONDUCT AIRFLOW TEST FOR EXISTING AIRFLOW RATE PRIOR TODEMOLITION. 5 REMOVE AIR TERMINAL COMPLETE, REMOVE AND CAP EXISTING DUCTWORK AT NORTH WALL. 6 PROTECT THERMOSTAT DURING CONSTRUCTION. #Revision Date T 6785 9 C D E 10 11 12 H J K L F G E.P OFFICEA115 OFFICEA114 CLASSROOMA116 CLASSROOM A113 STORAGEA111 CLASSROOM A120 OFFICE A102 WOMENS RRA108 UNOCCUPIED A124 MENS RRA109 OFFICEB106OFFICEB105 WOMENS RRB104 STORAGE B115C RISER RM A108A STORAGE A103A JANITOR A107 OFFICE A105 OFFICE A103 PARENT ROOM B100 SCIENCE LAB A121 UNOCCUPIED A122 UNOCCUPIED A123 BREAK ROOM A106 STORAGE A106A OFFICE A104 CORRIDOR A001 PRACTICE ROOM B117A STORAGE B101 STORAGEB102 CLINIC A101 LOBBY A100 VESTIBULE A003A STORAGEA117 UNOCCUPIEDA126 UNOCCUPIED A125 UNOCCUPIEDA127 OFFICEA119 CLASSROOMA118 UNOCCUPIED A130 UNOCCUPIEDA129 UNOCCUPIEDA128 VESTIBULE A003B STORAGEA112 CORRIDORA003 VESTIBULE A100A MENS RRB103CORRIDORA002 STORAGE A110A CLASSROOM B117 VESTIBULE A110B RRA110C GYMA110 1 2 3 10"Ø EAEC12/12300 SD24-12350 SD24-12350 SD24-8225 SD24-8225 SD24-12350 SD24-12350 EC24/24 SD 18"x12" TA CAP EXISTING DUCTWORK 12"Ø EA EC24/24 SD SD 12"x8" SA 18"x12" SA 1 1 1 1 1 1 SD24-8 A. B. DARK LINES INDICATE NEW WORK. LIGHT SOLID LINES INDICATE EXISTING MECHANICAL EQUIPMENT, DUCTWORK, PIPING, AND/OR MECHANICAL ACCESSORIES TO REMAIN AS-IS. CONTRACTOR TO FIELD VERIFY ACTUAL EXISTING CONDITIONS PRIOR TO BIDDING. GENERAL HVAC NOTES N 123456 A B C D E 123456 A B C D E Project No. Project Date Produced These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect. KEY PLAN B A 5/22/2023 12:48:35 PMC:\_RevitLocal\2023-067.POR_Bldg001_M_2023\2023-067.POR_Bldg001_M_2023_tkennedy.rvt2023-067.POR 05.22.2023 FIRST FLOOR HVAC PLAN- UNIT A MH1A1 Designer Author Coram Deo Academy Phase One Renovations 2023-067.POR_Coram Deo Academy_Phase One Renovations_525 Congressional Blvd,Carmel, IN 46032 MH1A1_ FIRST FLOOR HVAC PLAN - UNIT A 1/8" = 1'-0"1ALevel 1 - HVAC PLAN - UNIT A MECHANICAL HVAC PLAN NOTES #NOTE 1 REINSTALL AIR TERMINAL IN NEW CEILING. EXTEND EXISTING SHEETMETAL DUCTWORK TO INLET OFAIR TERMINAL. 2 ALTERNATE: ROUTE 12" ROUND EXHAUST AIR DUCT THROUGH ROOF TO EF-A1. EXHAUST FAN TO BECONTROLLED BY TIME CLOCK PER DETAIL ON M-501. TIME CLOCK TO MATCH EXISTING ROOFTOPNIGHT-SETBACK SCHEDULE. 3 PROVIDE NEW THERMOSTAT ON WALL. MOUNT THEMOSTAT WTIH TOP AT 48" ABOVE FINISHEDFLOOR. PROVIDE LOCKABLE PLASTIC CAGE LIKE BAPI GUARD. 4 INSTALL NEW ECUH IN CEILING PER MANUFACTURER'S RECOMMENDATIONS. #Revision Date TTTT T5 A 21 B C D G A5A4A3A2A1 E.P STORAGEB129B IDFB129 STORAGE B129A KITCHEN B128 CLASSROOM B127LIBRARYB135 STORAGEB112 CLASSROOMB121 CLASSROOMB120 STORAGEB142STORAGEB143STORAGEB144STORAGEB140STORAGEB139 RRB134 WOMENS RR B148 VESTIBULEB111B OFFICE B147 OFFICE B108 COPIERB109 PARENT ROOMB100 MENS RR B149 PLUMBING B123OFFICE B124KITCHENETTEB133 CLASSROOMB138 COMMONSB141 CLASSROOMB145 CLASSROOM B118 KITCHENETTE B122 OFFICE B119A CLASSROOMB110 CLASSROOM B126 STORAGEB146A STORAGEB146 CLASSROOM B130 CORRIDOR B001 OFFICE B131PRE-K B132 CLASSROOMB119 CHAPELB111 CAFETERIAB111A CLASSROOM B136 3 4 3 11 ECUH-1 4 ECUH-2 100 CFM 100 CFM 150 CFM 150 CFM 150 CFM150 CFM 250 CFM 350 CFM 300 CFM 300 CFM 350 CFM EX. EC24/12EX. EC24/12 SD24-8250 SD24-8250 250 CFM 250 CFM 24"x14" RA 400 CFM 400 CFM EX. EC24/12 EX. EC24/24EX. EC24/24 EC24/24 EC24/2410"Ø SA 10"Ø SA EX. EC24/12 18"x10" TA SD24-10300 SD24-10300 SD24-10300 SD24-10300 SD24-8150SD24-8150SD24-8150SD24-8150SD24-8150 SD24-8200 SD24-8200 SD24-8200 SD24-8200 SD24-10300 SD24-10300 SD24-10150 SD24-10250 1 1 1 1 11111 1 1 1 1 11 3 SD24-12 TBDI 24-06 TBDI 24-06 TBDI 24-06 TBDI 24-06 TBDI 24-06 EC24/241 1 1 1 1 1 EC24/24 CAP EXISTING DUCTWORKSD24-8250 1 200 CFM B137 CLASSROOM B137AOFFICE A. B. DARK LINES INDICATE NEW WORK. LIGHT SOLID LINES INDICATE EXISTING MECHANICAL EQUIPMENT, DUCTWORK, PIPING, AND/OR MECHANICAL ACCESSORIES TO REMAIN AS-IS. CONTRACTOR TO FIELD VERIFY ACTUAL EXISTING CONDITIONS PRIOR TO BIDDING. GENERAL HVAC NOTES N 123456 A B C D E 123456 A B C D E Project No. Project Date Produced These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect. KEY PLAN B A 5/22/2023 12:48:38 PMC:\_RevitLocal\2023-067.POR_Bldg001_M_2023\2023-067.POR_Bldg001_M_2023_tkennedy.rvt2023-067.POR 05.22.2023 FIRST FLOOR HVAC PLAN- UNIT B MH1B1 Designer Author Coram Deo Academy Phase One Renovations 2023-067.POR_Coram Deo Academy_Phase One Renovations_525 Congressional Blvd,Carmel, IN 46032 MH1B1_ FIRST FLOOR HVAC PLAN - UNIT B 1/8" = 1'-0"1ALevel 1 - HVAC PLAN - UNIT B MECHANICAL HVAC PLAN NOTES #NOTE 1 REINSTALL AIR TERMINAL IN NEW CEILING. EXTEND EXISTING SHEETMETAL DUCTWORK TO INLET OFAIR TERMINAL. 2 ALTERNATE: ROUTE 12" ROUND EXHAUST AIR DUCT THROUGH ROOF TO EF-A1. EXHAUST FAN TO BECONTROLLED BY TIME CLOCK PER DETAIL ON M-501. TIME CLOCK TO MATCH EXISTING ROOFTOPNIGHT-SETBACK SCHEDULE. 3 PROVIDE NEW THERMOSTAT ON WALL. MOUNT THEMOSTAT WTIH TOP AT 48" ABOVE FINISHEDFLOOR. PROVIDE LOCKABLE PLASTIC CAGE LIKE BAPI GUARD. 4 INSTALL NEW ECUH IN CEILING PER MANUFACTURER'S RECOMMENDATIONS. #Revision Date 6785 9 C D E 10 11 12 H J K L F G E.P EF-A1 5 A 21 B C D G A5A4A3A2A1 E.P A. B. C. DARK LINES INDICATE NEW WORK. LIGHT SOLID LINES INDICATE EXISTING MECHANICAL EQUIPMENT, DUCTWORK, PIPING, AND/OR MECHANICAL ACCESSORIES TO REMAIN AS-IS. CONTRACTOR TO FIELD VERIFY ACTUAL EXISTING CONDITIONS PRIOR TO BIDDING. ALL ROOF WORK SHALL BE IN ACCORDANCE WITH OWNER ’S EXISTING ROOF WARRANTY. WARRANTY SHALL BE MAINTAINED. GENERAL ROOF NOTES N 123456 A B C D E 123456 A B C D E Project No. Project Date Produced These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect. KEY PLAN B A 5/22/2023 12:48:49 PMC:\_RevitLocal\2023-067.POR_Bldg001_M_2023\2023-067.POR_Bldg001_M_2023_tkennedy.rvt2023-067.POR 05.22.2023 MECHANICAL ROOF PLAN MR101 Designer Author Coram Deo Academy Phase One Renovations 2023-067.POR_Coram Deo Academy_Phase One Renovations_525 Congressional Blvd,Carmel, IN 46032 MR101_ MECHANICAL ROOF PLAN 3/32" = 1'-0"1MECHANICAL HVAC ROOF PLAN - AREA A 3/32" = 1'-0"2MECHANICAL HVAC ROOF PLAN - AREA B #Revision Date ELEC HTG RETURN GRILLE AND TRANSFER DUCTWORK. REFER TO HVAC FLOOR PLANS AND SCHEDULES FOR DUCT AND GRILLE SIZES. 1" INTERNALLY LINED 22 GAUGE SHEET METAL DUCT.DUCT LINING TO BE BLACK. 8" CLEAR (MIN.) UNLESS OTHERWISENOTED ON DRAWINGS.8" MIN.CEILING 3"4'-0" MIN. LENGTH NOTE:MAINTAIN ALL DIMENSIONS WHERE POSSIBLE EXCEPT WHEN LIMITED BY STRUCTURE, FIR PROTECTION PIPING, ELECTRICAL CONDUIT, ETC. EXHAUST DUCT. REFER TO HVAC FLOOR PLANS FOR EXACT SIZE AND ROUTING ROOF STRUCTURE, REFER TO STRUCTURAL DRAWINGS FOR TYPE ROOF CONSTRUCTION, SEE ARCHITECTURAL DRAWINGS FOR TYPE PRE-FABRICATED INSULATED ROOF CURB SECURE FAN TO ROOF CURB AS REQUIRED WITH A MINIMUM OF TWO (2) FASTENERS PER SIDE MOTOR ALUMINUM HOUSING FAN 1.NOTE:ALL POWER ROOF VENTILATORS SHALL BE MOUNTED LEVEL. PROVIDE SLOPED CURBS AND SHIMS AS REQUIRED FOR SLOPED ROOFS. REFER TO ARCHITECTURAL DRAWINGS FOR PITCH OF ROOF. ROCK WOOL ROCK WOOL CEILINGEGGCRATE TYPERETURN GRILLE 1" BLACK RIGIDINSULATION BOARD WASHER WITH BLACK NEOPRENE PAD ON UNDERSIDE WIRE SUPPORT ATTACHED TO STRUCTURE 8" MIN.SIDES 12" ALL FOUR AIR FLOW LOW PRESSURE SUPPLY BRANCH DUCT 45°/90° ENTRY FITTING WITH MANUAL VOLUME DAMPER LIKE FLEXMASTER MODEL STO AT ALL SUPPLY AIR BRANCH DUCTWORK TAKE-OFFS, AND/OR RECTUANGULAR TO ROUND WHERE REQUIRED. SUPPLY DIFFUSER CEILING SECURE FLEXIBLE DUCT TO SUPPLY DIFFUSER NECK WITH STAINLESS STEEL DRAWBAND TO INNER PART OF FLEX DUCT. PROVIDE FOIL TAPE TO SECURE INSULATION OVER DRAW BAND. SQUARE-TO-ROUND FITTING FOR SQUARE NECK SUPPLY DIFFUSERS INSULATED FLEXIBLE DUCTWORK MAXIMUM 5'-0" IN LENGTH AND NO MORE THAN ONE (1) 90° TURN FLEX BOOT LIKE MODEL "FLEXRIGHT" BY BUILDRIGHT PRODUCTS WHERE DIFFUSER IS LOCATED IN CEILING SPACE NOT USED AS A RETURN PLENUM, PROVIDE MANUFACTURER'S INSULATED BACK PAN ON DIFFUSER, AND FOIL TAPE EDGES. 1" BAND CLAMP WITH WIRE (OPTIONAL) MINIMUM 1" WIDE CLAMP WIRE SUPPORT STRAP BRACING SHALL BEPROVIDED AT A MAXIMUMOF 3'-0" ON CENTERS MAXIMUM SAG SHALL BE 1/2"PER FOOT OF SUPPORT SPACING DETAIL 1 DETAIL 2 DETAIL 3 NOTES: 1.METALLIC FLEXIBLE DUCTWORK SHALL BE ATTACHED USING A MINIMUM OF THREE (3) #8 SHEET METAL SCREWS EQUALLY SPACED AROUND THE DUCTWORK CIRCUMFERENCE. DUCTWORK LARGER THAN 12" SHALL HAVE A MINIMUM OF FIVE (5) #8 SHEET METAL SCREWS. SCREWS SHALL BE LOCATED AT LEAST 1/2" FROM THE DUCTWORK END. 2.NON-METALLIC FLEXIBLE DUCTWORK SHALL BE SECURED TO THE SLEEVE OR COLLAR USING A DRAW BAND. IF THE DUCTWORK COLLAR EXCEEDS 12" THE DRAW BAND MUST BE POSITIONED BEHIND A BEAD ON THE METAL COLLAR. 3.INSULATION AND VAPOR BARRIERS PRESENT ON FACTORY-FABRICATED DUCTWORK SHALL BE FITTED OVER THE CORE CONNECTION AND SHALL BE SUPPLEMENTALLY SECURED WITH A DRAW BAND. 4.FLEXIBLE DUCTWORK SEALING SHALL BE A CLASS "B" SEAL FOR LOW PRESSURE DUCTWORK. 5.SUPPORT SYSTEM SHALL NOT DAMAGE OR CAUSE OUT-OF-ROUND SHAPE. EXHAUST FAN SCHEDULE - 23 34 23 IDENTITY DATA WEIGHT (LBS) FAN DATA SOUND CRITERIA ELECTRICAL DATA UNIT CONTROL NOTESMARKMANUFACTURERMODELSERVICESFAN TYPE DRIVE TYPE AIRFLOW (CFM) ESP (IN-WG)RPM HP BHP SONES DBA VOLTS (V)PH FREQ (HZ) EF-1GREENHECKCUE-099-VGSCIENCE40UPBLAST CENTRIFUGALDIRECT990 0.75 1535.00 0.25 0.24 11.6 63 120 1 60 TIME CLOCK 1-4 EXHAUST FAN SCHEDULE NOTES: 1. DISCONNECT BY MANUFACTURER. 2. SEE M-700 SERIES SHEETS FOR TEMPERATURE CONTROL INFORMATION. 3. FAN SPEED CONTROLLER FOR BALANCING. 4.24-HOUR TIMECLOCK TO ENERGIZE FAN ON SAME SCHEDULE AS ROOFTOP OCCUPANCY SCHEDULE. ELECTRIC CABINET UNIT HEATER SCHEDULE - 23 82 39 IDENTITY DATA WEIGHT (LBS) HEATING DATA FAN DATA ELECTRICAL DATA NOTESMARKMANUFACTURERMODEL CAPACITY (KW)STAGES AIRFLOW (CFM) ESP (IN-WG)FAN TYPE DRIVE VOLTS (V)PH FREQ (HZ) FLA (A) MOCP (A) ECUH-1Q-MARKEFF4007 23 4.0 1 150 0.25 FC CENTRIFUGAL DIRECT 277 1 60 14.4 14.4 1 ECUH-2Q-MARKEFF4007 23 4.0 1 150 0.25 FC CENTRIFUGAL DIRECT 277 1 60 14.4 14.4 1 ELECTRIC CABINET UNIT HEATER SCHEDULE NOTES: 1. DISCONNECT SWITCH BY MANUFACTURER. DISCONNECT SWITCH AND ALL INTERLOCK RELAYS TO BE INSTALLED WITHIN HEATER ENCLOSURE. EXHAUST FAN CONTROL: THE MOTORIZED BACKDRAFT DAMPER (MB-DPR) SHALL BE DRIVEN OPEN AND PROVEN VIA END-SWITCH CONTACTS TO PREVENT OPERATION OF THE EXHAUST FAN MOTOR WHEN CLOSED. DAMPER ACTUATOR WITH INTEGRAL END-SWITCH FURNISHED AND INSTALLED BY TCC. THE EXHAUST FAN SHALL BE STARTED ACCORDING TO THE OWNER-DEFINED SCHEDULE. IF THE EXHAUST FAN STATUS (EF-S) DOES NOT MATCH THE COMMANDED VALUE AFTER STROKE TIME PLUS 15 SECONDS (ADJ), AN ALARM SHALL BE GENERATED. SEE ELECTRICAL DRAWINGS FOR MOTOR STARTER LOCATION INFORMATION.BIEF-S HWBO MB-DPR NC EXHAUST AIRROOM AIR ZN-T HEATER SEQUENCE OF OPERATION ZONE TEMPERATURE CONTROL: INTEGRAL THERMOSTAT (ZN-T) WILL ENERGIZE THE ELECTRIC HEATING TO MAINTAIN THE ZONE TEMPERATURE AT 70F (ADJ). MANUFACTURER PROVIDED AND WIRED SAFETIES SHALL ENSURE SAFE OPERATION. AREASERVED HINGED ACCESS DOOR FOR FIRE DAMPER ACCESS FIRE RATED CHASE WALL, VERIFY EXACT FIRE RATING AND CONSTRUCTION ON ARCHITECTURAL DRAWINGS SOLID CEILING CONSTRUCTION ACCESS DOOR/PANEL SOLID CEILING CONSTRUCTION, VERIFY TYPE AND CONSTRUCTION ON ARCHITECTURAL DRAWINGS DUCTWORK TYPE "B" FIRE DAMPER FIRE DAMPER INSTALLATION SHALL BE IN STRICT ACCORDANCE WITH THE MANUFACTURER'S WRITTEN INSTRUCTIONS AND ALL UNDERWRITER'S LABORATORY (UL), FEDERAL, STATE AND LOCAL CODE REQUIREMENTS. FIRE DAMPER RATING SHALL MATCH FIRE RATING OF CHASE CONSTRUCTION. REFER TO ARCHITECTURAL DRAWINGS FOR RATING. DIVISION 23 CONTRACTOR SHALL FURNISH AND INSTALL A HINGED ACCESS DOOR IN THE DUCTWORK SIZED IN ACCORDANCE WITH THE SCHEDULE AND LOCATED TO PERMIT REPLACEMENT OF FUSIBLE LINK. LABEL FIRE DAMPER ACCESS DOOR WITH "FIRE DAMPER ACCESS." DIVISION 23 CONTRACTOR SHALL FURNISH ACCESS DOOR/PANEL FOR SOLID CEILING CONSTRUCTION IN ACCORDANCE WITH DIVISION 8 SPECIFICATION SECTION "ACCESS DOORS AND PANELS". ACCESS DOOR/PANEL LOCATED IN SOLID CEILING CONSTRUCTION SHALL BE NO SMALLER IN SIZE THAN THE ACCESS DOOR LOCATED IN THE DUCTWORK. NOTES: 1. 2. 3. 4. ACCESS DOOR / PANEL SCHEDULE DUCTWORK WIDTH ACCESS DOOR 6"8" - 12"13" - 18"19" - 36"37" - UP 6" x 6"8" x 8"12" x 12"18" x 18"24" x 24" N 123456 A B C D E 123456 A B C D E Project No. Project Date Produced These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect. KEY PLAN B A 5/22/2023 12:48:51 PMC:\_RevitLocal\2023-067.POR_Bldg001_M_2023\2023-067.POR_Bldg001_M_2023_tkennedy.rvt2023-067.POR 05.22.2023 MECHANICAL DETAILS M-501 Designer Author Coram Deo Academy Phase One Renovations 2023-067.POR_Coram Deo Academy_Phase One Renovations_525 Congressional Blvd,Carmel, IN 46032 M-501_ MECHANICAL DETAILSNOT TO SCALE1ARETURN GRILLE SOUND TRAP DETAIL NOT TO SCALE2A POWER ROOF VENTILATOR INSTALLATION DETAIL NOT TO SCALE1BOPEN PLENUM RETURN GRILLE DETAIL NOT TO SCALE1C SUPPLY DIFFUSER FLEXIBLE DUCT CONNECTION DETAIL NOT TO SCALE2BINSULATED FLEXIBLE DUCTWORK DETAIL NOT TO SCALE5B ELECTRIC UNIT HEATER SEQUENCE OFOPERATIONS NOT TO SCALE5AEXHAUST FAN SEQUENCE OF OPERATIONS NOT TO SCALE4CFIRE DAMPER (WALL) DETAIL 233713 DIFFUSERS, REGISTERS, AND GRILLES IDENTITY DATA NECK SIZE (IN)MODULE SIZE MATERIAL NOTESMARKDESCRIPTIONMANUFACTURERMODELØWL TBDI 24-06T-BAR SUPPLY DIFFUSER NAILOR 5810I 0"0"0" EC12/12EGG CRATE FACE RETURN PRICE 80 12"12" EC24/24EGG CRATE FACE RETURN PRICE 80 24"24" SD24-8 SQUARE CONE DIFFUSER PRICE ASCDA 8"24"24" SD24-10 SQUARE CONE DIFFUSER PRICE ASCDA 10"24"24" SD24-12 SQUARE CONE DIFFUSER PRICE ASCDA 12"24"24" #Revision Date AVAWAIRCWGASGWHWABANDONED ACID-RESISTANT VENTABANDONED ACID-RESISTANT WASTEABANDONED AIRABANDONED COLD WATERABANDONED GASABANDONED GREASE WASTEABANDONED HOT WATERABANDONED PIPING SYSTEMSHWRABANDONED HOT WATER RETURNFPABANDONED FIRE PROTECTIONN2ABANDONED NITROGENSTABANDONED STORMVACABANDONED VACUUMVABANDONED VENTWABANDONED WASTEGALVGALVANIZEDSTPHWRHOT WATER RETURNSTS, STRSTRUCTHWCPHRHOHDHORIZHOURHORIZONTALHEAD (FT.)HUB OUTLETHBGCGPMGTGPHHOSE BIBGENERAL CONTRACTORGALLONS PER MINUTEGALLONS PER HOURGREASE TRAPSTDSTSSKSSDSSSPECSPGSHTSKSHSECTSFSBSCWFLOOR DRAIN FIRE PROTECTION CONTRACTORFIRE DEPARTMENT CONNECTIONGGALGAFPCFOVFPFTFPMFTGGALLONGAUGENATURAL GASFIRE PROTECTIONFUEL OIL VENTFEET PER MINUTEFOOTINGFOOT/FEETFEFHCFHFOSFORFLRFCOFDCFDFIRE EXTINGUISHERFUEL OIL RETURNFUEL OIL SUPPLYFIRE HOSE CABINETFLOORFIRE HOSEFLOOR CLEANOUTRORPMRMRECIRRHRDRCPRPVCEXISTEXP°FETEWCEWDEGREES FAHRENHEITEXPANSIONEXISTINGEXPANSION TANKEMERGENCY EYEWASHELECTRIC WATER COOLEREMERENCLESEQUIPEFFELEVELECEMERGENCYEMERGENCY SHOWEREQUIPMENTENCLOSUREELEVATIONELECTRICEFFICIENCYPSIGPRESSPRVPSIPREFABPPMPOCPIVPLTPERPIPHPDPCSTORAGE TANK PUMPSTORAGE TANK SUPPLY AND RETURNSTRUCTURE(E), (AL)SUB SURFACE (FOOTING) DRAINSTORAGE TANKSTAINLESS STEELSERVICE SINKSTANDARDSPECIFICATIONSSPECIAL GASSHEETSINKSOFT COLD WATER (DOMESTIC)SQUARE FOOTSHOWERSECTIONSITZ BATHRODDING HOLEREVERSE OSMOSIS WATERREVOLUTIONS PER MINUTEROOMRECIRCULAT(E), (OR), (ING)REINFORCED CONCRETE PIPEROOF DRAINTHERMAL RESISTANCEPOLYVINYL CHLORIDEPOST INDICATOR VALVEPOINT OF CONNECTION (NEW TO EXISTING)POUNDS PER SQUARE INCHPRESSURE REDUCING VALVEPOUNDS PER SQUARE INCH GAUGEPRESSUREPARTS PER MILLIONPREFABRICATEDPLASTER TRAPPRESSURE DROP (IN OR WG AS NOTED)PERCENTPRESSURE INDICATORPHASEPLUMBING CONTRACTORMISCECOECDNDSDFDWGDWHEXTERIOR CLEANOUTELECTRICAL CONTRACTORDRINKING FOUNTAINDOMESTIC WATER HEATERDRAWINGDOWNSPOUTDOWNCWDCOLD WATER (DOMESTIC)DRAINPOSDOFOIOFCIOFDOEOAONANONTSNICNCNMTDCONTRACTOR FURNISHED/OWNER INSTALLEDBRITISH THERMAL UNIT PER HOURCOCICONNCO2CFOICARBON DIOXIDECONNECTIONCAST IRONCLEANOUTBTCDBTUHBOPBLDGBATHTUBCONDENSATE DRAINBOTTOM OF PIPINGBUILDINGMINMHMECHMCMBHMSMBMAXLPCMALVLFCLPLECAREA DRAIN AMPERE (AMP, AMPS)AAWBFCAMPARCHAVAPDAPPROXCOMPRESSED AIRBELOW FINISHED CEILINGACID WASTEAIR PRESSURE DROP (IN WG)ARCHITECT (URAL)APPROXIMAT(E), (LY)ACID VENTADJAEAFFALTERADADAADJUSTABLEABOVE FINISHED FLOORANESTHESIA EVACUATIONALTERNATEAMERICAN DISABILITIES ACTLBSLABLALKWINVKECININDICINSULINTINCLIDHZVACUUM PUMP DISCHARGEW/OWITHOUTMISCELLANEOUSOWNER FURNISHED/CONTRACTOR INSTALLEDOWNER FURNISHED/OWNER INSTALLEDOPEN SITE DRAINPUMPORAL EVACUATIONOVERFLOW DRAINOUTSIDE AIROXYGENNOT APPLICABLENORMALLY CLOSEDNORMALLY OPENNOT TO SCALENOT IN CONTRACTNITROGENMOUNTEDZNWTRYDWPDWPZONEWATER PRESSURE DROPYARD DRAINWEATHERPROOFWATERTHOUSANDS OF BTU PER HOURMECHANICALMINIMUMMANHOLEMECHANICAL CONTRACTORMOP SINKMOP BASINMAXIMUMLABORATORY FURNISHINGS CONTRACTORLABORATORY PLUMBING CONTRACTORLABORATORY EQUIPMENT CONTRACTORLABORATORY VACUUMMEDICAL AIRLIQUID PETROLEUMWHWGW.C.WCOWCW/VVVPDVTVTRWATER CLOSETWATER COLUMNWALL CLEANOUTWATER GAUGEWALL HYDRANTVITRIFIED TILEVENT THROUGH ROOFVACUUM VENTWITHVBVERTVIFVCVACVARVAVACUUM BREAKERVERIFY IN FIELDVACUUM CLEANINGVERTICALVOLT AMPEREVACUUMVARIABLETEMPERATURE AND PRESSURETHERMOSTATIC MIXING VALVEUNLESS NOTED OTHERWISEINVERTKITCHEN EQUIPMENT CONTRACTORLABORATORY AIRLABORATORYPOUNDKILOWATTLAVATORYINCH/INCHESINSULAT(E), (ED), (ION)INCLUD(E), (ED)INDICATORINTERIORFREQUENCY (MEGAHERTZ)INSIDE DIAMETERUNOURTYP.TSTPURINALTRAP PRIMERTAMPER SWITCHTYPICALTEMPTMVT&PSUTEMPERATURESHOWER UNITABBREVIATIONSHWHOT WATER (DOMESTIC)TTEMPERED WATERDWSDOMESTIC WATER SOFTNERHOT WATER RECIRCULATING PUMPABBREVIATIONS2M-3013M-501SECTION REFERENCEDETAIL REFERENCEPLAN NOTEDRAWING NOTATIONSNOTE: ALL SYMBOLS AND ABBREVIATIONSMAY NOT BE USED FOR THIS PROJECTDEMONEWNEW TO EXISTINGDEMO TO THIS POINTEQUIPMENT TAG -(SEE SCHEDULE SHEETS)XXX-1XXX-1FIXTURE TAG -(SEE SCHEDULE SHEETS)FIRE PROTECTION SYMBOLSATSFFALARM VALVEZONE VALVE (OS&Y)SIDEWALL SPRINKLER HEADCONCEALED PENDANT SPRINKLER HEADUPRIGHT SPRINKLER HEADPENDANT SPRINKLER HEADDRY PENDANT SPRINKLER HEADFIRE DEPT. CONNECTIONPOST INDICATOR VALVEFLOW SWITCHTAMPER SWITCHFIRE WATER MAIN140° HW140° HWR160° HW160° HWRAVAWAIRCWHWHWRFPDFPFPPAFPWG (11 in-wc)G (2 psig)GWLCWLHRLALHWLVACLVEN2PWRPWSRORORSCWSHWSTTWVACVW140° DOMESTIC HOT WATER140° DOMESTIC HOT WATER RETURN160° DOMESTIC HOT WATER160° DOMESTIC HOT WATER RETURNACID RESISTANT VENTACID RESISTANT WASTEAIRDOMESTIC COLD WATERDOMESTIC HOT WATERDOMESTIC HOT WATER RETURNFIRE PROTECTION DRYFIRE PROTECTION OTHERFIRE PROTECTION PRE-ACTIONFIRE PROTECTION WETGAS (11" w.c.)GAS (2 psig)GREASE WASTELAB AIRLAB COLD WATERLAB HOT WATERLAB HOT WATER RETURNLAB VACUUMLAB VACUUM EXHAUSTNITROGENPURE WATER RETURNPURE WATER SUPPLYREVERSE OSMOSIS WATERREVERSE OSMOSIS WATER RETURNSOFT COLD WATERSOFT HOT WATERSTORMTEMPERED WATERVACUUMVENTWASTEPIPING SYSTEMSCACOMBUSTION AIREAEXHAUST AIRG (6 in-wc)GAS (6" w.c.)G (5 psig)GAS (5 psig)RCWRAW COLD WATERGENERAL DUTY VALVES & FITTINGSACONCENTRIC REDUCERDOMESTIC COLD WATER VALVE BOXECCENTRIC REDUCERPRESSURE REDUCING VALVE(P) = PRESSUREVACUUM BREAKERGAS COCKPETE'S PLUGPIPE EXPANSION JOINTFLEXIBLE PIPING CONNECTORY-STRAINER W/BLOWDOWNVALVE & CAPPIPE ANCHORSPIPE GUIDESTHERMOMETER WELLAUTOMATIC AIR VENTGAUGE CONNECTION(S) & WELLTHERMOMETER & WELLMANUAL AIR VENTAUTOMATIC BALANCING VALVETWO-WAY CONTROL VALVETHREE-WAY CONTROL VALVEUNIONMANUAL BALANCING VALVEANGLE VALVEPLUG VALVEPRESSURE REGULATING VALVEBUTTERFLY VALVEVALVE - SEE SPECIFICATIONSFOR VALVE TYPEPIPE CONTINUED ON ANOTHERDRAWINGCHECK VALVECAPPED PIPERISE IN PIPINGDROP IN PIPINGN123456ABCDE123456ABCDEProject No.Project DateProducedThese Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect.KEY PLANBA5/22/2023 6:05:33 PMC:\_RevitLocal\2023-067.POR_Bldg001_P_2023\2023-067.POR_Bldg001_P_2023_jbaughman.rvt2023-067.POR05.22.2023PLUMBING SYMBOLS ANDABBREVIATIONSP-001Designer JJBCoram DeoAcademyPhase OneRenovations2023-067.POR_Coram Deo Academy_Phase One Renovations_525 Congressional Blvd,Carmel, IN 46032P-001_ PLUMBING SYMBOLS AND ABBREVIATIONS#RevisionDate CRCRT1.EXISTING PIPE ROUTING, AS SHOWN ON DRAWINGS, IS BASED UPON RECORD DOCUMENTS AND FIELD SURVEYS. ACTUAL ROUTE OF CONCEALED PIPING MAY VARY. CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY PIPE ROUTING PRIOR TO SAW CUTTING OF FLOOR SLABS.2.CONTRACTOR SHALL JET AND THOROUGHLY FLUSH EXISTING SANITARY SEWERS WHERE DOCUMENTS CALL FOR NEW WASTE PIPE CONNECTIONS.3.ALL UNDERGROUND SANITARY OR STORM PIPING SHOWN TO BE ABANDONED IN PLACE SHALL BE CAPPED AND FILLED WITH FLOWABLE FILL.4.WHERE PLUMBING FIXTURE ROUGH-IN PIPING IS SHOWN TO BE ABANDONED IN WALLS OR BELOW FLOOR SLAB, ROUGH-INS SHALL BE REMOVED TO A POINT BEYOND THE FINISHED SURFACE AND CAPPED. PATCH SURFACE TO MATCH EXISTING FINISH.5.IN AREAS WHERE A FULL REMODEL IS INDICATED ON THE DRAWINGS, CONTRACTOR SHALL REMOVE ALL OVERHEAD PIPING AND HANGERS COMPLETE UNLESS OTHERWISE INDICATED.6.WHERE SANITARY OR ACID VENT THROUGH ROOF IS SHOWN TO BE ABANDONED IN PLACE, CONTRACTOR SHALL PERMANENTLY CAP PIPE ABOVE AND BELOW ROOF FOR A WATER TIGHT SEAL.PLUMBING RENOVATION NOTES667788559CDEE101011111212HHJKLLFGGE.PE.P1OFFICEA115OFFICEA114CLASSROOMA116CLASSROOMA113STORAGEA111UnoccupiedUnoccupiedOFFICEA102WOMENS RRA108UNOCCUPIEDA124MENS RRA109OFFICEB107OFFICEB106OFFICEB105WOMENS RRB104COPIERB109STORAGEB115CSTORAGEB115BRISER RMA108ASTORAGEA103AJANITORA107OFFICEA105OFFICEA103PARENT ROOMB100SCIENCE LABA121UNOCCUPIEDA122UNOCCUPIEDA123BREAK ROOMA106STORAGEA106AOFFICEA104CORRIDORA001PRACTICE ROOMB117ASTORAGEB101STORAGEB102CLINICA101LOBBYA100VESTIBULEA003ASTORAGEA117UNOCCUPIEDA126UNOCCUPIEDA125UNOCCUPIEDA127OFFICEA119CLASSROOMA118UNOCCUPIEDA130UNOCCUPIEDA129UNOCCUPIEDA128VESTIBULEA003BSTORAGEA112CORRIDORA003VESTIBULEA100AMENS RRB103CORRIDORA002STORAGEA110ACLASSROOMB115CLASSROOMB117VESTIBULEA110BGYMA110CLASSROOMA120RRA110CN123456ABCDE123456ABCDEProject No.Project DateProducedThese Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect.KEY PLANBA5/22/2023 6:03:51 PMC:\_RevitLocal\2023-067.POR_Bldg001_P_2023\2023-067.POR_Bldg001_P_2023_jbaughman.rvt2023-067.POR05.22.2023LEVEL 1 DEMOLITIONPLUMBING PLAN -UNIT APD1A1Designer JJBCoram DeoAcademyPhase OneRenovations2023-067.POR_Coram Deo Academy_Phase One Renovations_525 Congressional Blvd,Carmel, IN 46032PD1A1_ LEVEL 1 DEMOLITION PLUMBING PLAN -UNIT ADEMOLITION PLAN NOTES#NOTE1REMOVE WATER CLOSET AND ROUGH-IN PIPING FOR DOMESTIC WATER ANDSANITARY WASTE BACK TO WITHIN CHASE. PROVIDE TEMPORARY CAPS ANDPREPARE FOR RECONNECTION.1/8" = 1'-0"2ALEVEL 1 DEMOLITION PLUMBING PLANS -ART ROOM#RevisionDate TTTTTT1.EXISTING PIPE ROUTING, AS SHOWN ON DRAWINGS, IS BASED UPON RECORD DOCUMENTS AND FIELD SURVEYS. ACTUAL ROUTE OF CONCEALED PIPING MAY VARY. CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY PIPE ROUTING PRIOR TO SAW CUTTING OF FLOOR SLABS.2.CONTRACTOR SHALL JET AND THOROUGHLY FLUSH EXISTING SANITARY SEWERS WHERE DOCUMENTS CALL FOR NEW WASTE PIPE CONNECTIONS.3.ALL UNDERGROUND SANITARY OR STORM PIPING SHOWN TO BE ABANDONED IN PLACE SHALL BE CAPPED AND FILLED WITH FLOWABLE FILL.4.WHERE PLUMBING FIXTURE ROUGH-IN PIPING IS SHOWN TO BE ABANDONED IN WALLS OR BELOW FLOOR SLAB, ROUGH-INS SHALL BE REMOVED TO A POINT BEYOND THE FINISHED SURFACE AND CAPPED. PATCH SURFACE TO MATCH EXISTING FINISH.5.IN AREAS WHERE A FULL REMODEL IS INDICATED ON THE DRAWINGS, CONTRACTOR SHALL REMOVE ALL OVERHEAD PIPING AND HANGERS COMPLETE UNLESS OTHERWISE INDICATED.6.WHERE SANITARY OR ACID VENT THROUGH ROOF IS SHOWN TO BE ABANDONED IN PLACE, CONTRACTOR SHALL PERMANENTLY CAP PIPE ABOVE AND BELOW ROOF FOR A WATER TIGHT SEAL.PLUMBING RENOVATION NOTES1.SPRINKLER SCHEDULE:ROOMS WITHOUT CEILINGS:UPRIGHT SPRINKLERSROOMS WITH CEILINGS:SEMI-RECESSED SPRINKLER HEADSWALL MOUNTING:SIDEWALL SPRINKLER HEADSSUBJECT TO FREEZING:DRY PENDANT SPRINKLER HEADS2.ALL SPRINKLER COVERAGE SHALL COMPLY WITH MINIMUM STANDARDS AS ESTABLISHED BY NFPA 13, INCLUDING OFFICE SPACES.3.WHERE APPLICABLE, INCOMING FIRE PROTECTION WATER SERVICE AND FIRE DEPARTMENT CONNECTION MAIN FROM 5'-0" OUTSIDE OF BUILDING TO FLANGED CONNECTION 12" ABOVE FLOOR OR FROM WALL SHALL BE PROVIDED BYDIVISION 22.4.WHERE MAIN ELECTRIC ROOMS HAVE A 2-HOUR RATING, DO NOT INSTALL SPRINKLER COVERAGE.5.DO NOT ROUTE SPRINKLER PIPING OVER ANY TELEDATA, IDF, MDF OR SIMILAR ROOM. PROVIDE SIDEWALL SPRINKLER COVERAGE FOR THE SPACE WITH HEAD LOCATED ABOVE DOOR WHEREVER POSSIBLE.6.DO NOT ROUTE SPRINKLER PIPING OVER ANY ELECTRICAL ROOM. PROVIDE SIDEWALL SPRINKLER COVERAGE FOR THE SPACE WITH HEAD LOCATED ABOVE DOOR WHEREVER POSSIBLE. FIRE PROTECTION GENERAL NOTES6677885549AA2211BCDEE101011111212HHJKLFFGGA5A5A4A4A3A3A2A2A1A1E.PE.PN123456ABCDE123456ABCDEProject No.Project DateProducedThese Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect.KEY PLANBA5/22/2023 6:04:07 PMC:\_RevitLocal\2023-067.POR_Bldg001_P_2023\2023-067.POR_Bldg001_P_2023_jbaughman.rvt2023-067.POR05.22.2023LEVEL 1 FIREPROTECTION PLUMBINGPLANFP101Designer JJBCoram DeoAcademyPhase OneRenovations2023-067.POR_Coram Deo Academy_Phase One Renovations_525 Congressional Blvd,Carmel, IN 46032FP101_ LEVEL 1 FIRE PROTECTION PLUMBING PLAN1/16" = 1'-0"2ALEVEL 1 FIRE PROTECTION PLUMBINGPLAN#RevisionDate 1.EXISTING PIPE ROUTING, AS SHOWN ON DRAWINGS, IS BASED UPON RECORD DOCUMENTS AND FIELD SURVEYS. ACTUAL ROUTE OF CONCEALED PIPING MAY VARY. CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY PIPE ROUTING PRIOR TO SAW CUTTING OF FLOOR SLABS.2.CONTRACTOR SHALL JET AND THOROUGHLY FLUSH EXISTING SANITARY SEWERS WHERE DOCUMENTS CALL FOR NEW WASTE PIPE CONNECTIONS.3.ALL UNDERGROUND SANITARY OR STORM PIPING SHOWN TO BE ABANDONED IN PLACE SHALL BE CAPPED AND FILLED WITH FLOWABLE FILL.4.WHERE PLUMBING FIXTURE ROUGH-IN PIPING IS SHOWN TO BE ABANDONED IN WALLS OR BELOW FLOOR SLAB, ROUGH-INS SHALL BE REMOVED TO A POINT BEYOND THE FINISHED SURFACE AND CAPPED. PATCH SURFACE TO MATCH EXISTING FINISH.5.IN AREAS WHERE A FULL REMODEL IS INDICATED ON THE DRAWINGS, CONTRACTOR SHALL REMOVE ALL OVERHEAD PIPING AND HANGERS COMPLETE UNLESS OTHERWISE INDICATED.6.WHERE SANITARY OR ACID VENT THROUGH ROOF IS SHOWN TO BE ABANDONED IN PLACE, CONTRACTOR SHALL PERMANENTLY CAP PIPE ABOVE AND BELOW ROOF FOR A WATER TIGHT SEAL.PLUMBING RENOVATION NOTES667788559CDEE101011111212HHJJKLLFGE.PE.POFFICEA104CORRIDORA001OFFICEA105CORRIDORA002BREAK ROOMA106STORAGEA106ASCIENCE LABA121CLASSROOMA120CORRIDORA003OFFICEA115OFFICEA114VESTIBULEA003BCLASSROOMA113CLASSROOMA116CORRIDORA003CORRIDORA003STORAGEA112STORAGEA111CLASSROOMA118OFFICEA119STORAGEA117GYMA110STORAGEA110AMENS RRA109WOMENS RRA108EX. 4" WEX. 4" W3" WFD-1FCO3" W3" W3" W2" W2" W2" W3" W3" W2" W2" W3" W2" W2" W3" W2" W2" W3" W3" W3" W3" WFCO3" W2" W2" W12" W111N123456ABCDE123456ABCDEProject No.Project DateProducedThese Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect.KEY PLANBA5/22/2023 6:04:19 PMC:\_RevitLocal\2023-067.POR_Bldg001_P_2023\2023-067.POR_Bldg001_P_2023_jbaughman.rvt2023-067.POR05.22.2023FOUNDATION PLUMBINGPLANS -UNIT A -ALTERNATEPF1A1Designer JJBCoram DeoAcademyPhase OneRenovations2023-067.POR_Coram Deo Academy_Phase One Renovations_525 Congressional Blvd,Carmel, IN 46032PF1A1_ FOUNDATION PLUMBING PLANS -UNIT A -ALTERNATEFOUNDATION PLUMBING PLAN NOTES#NOTE1ROUTE PIPING UP INTO UTILITY CHASE BEHINDE CABINETS.4INSTALL PIPE SLEEVE AT EACH WALL PENETRATION 2 SIZES LARGER THAN PIPEPASSING THROUGH THE WALL.5CONTRACTOR TO ROUTE TO GAS METER AND CONNECT. COORDINATE WITHUTILITY COMPANY TO ENSURE THAT METER IS SIZED APPROPRIATELY AND UPSIZEIF NEEDED TO ACCOMODATE 30,000 BTUH FOR SCIENCE LAB GAS TURRETS.6DROP IN WALL AND ROUTE TO SINKS AND TURRETS WITHIN UTILITY CHASE BEHINDTHE CABINET BASES.1/8" = 1'-0"2AFOUNDATION PLUMBING PLANSPLUMBING FIXTURE ROUGH-IN LEGENDMARKFIXTURE CONNECTIONCWHWWVEWES-1FD-13"SK-1SK-21/2"1/2"1 1/2"1 1/2"SK-31/2"1/2"1 1/2"1 1/2"#RevisionDate T667788559CDDEE101011111212HHJJKLFFGE.PE.PEX. 1/2" CW12CLASSROOMB115CORRIDORB001PARENT ROOMB100OFFICEB107OFFICEB106OFFICEB105RRA110CSTORAGEB115CSTORAGEB115BCOPIERB109LOBBYA100CORRIDORB001MENS RRB103WOMENS RRB104MENS RRA109WOMENS RRA108STORAGEA103ARISER RMA108ASTORAGEB102OFFICEA103CLINICA101CORRIDORA001OFFICEA102GYMA110VESTIBULEA110BCLASSROOMB117PRACTICE ROOMB117ASK-11 1/2" V1/2" HW1.EXISTING PIPE ROUTING, AS SHOWN ON DRAWINGS, IS BASED UPON RECORD DOCUMENTS AND FIELD SURVEYS. ACTUAL ROUTE OF CONCEALED PIPING MAY VARY. CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY PIPE ROUTING PRIOR TO SAW CUTTING OF FLOOR SLABS.2.CONTRACTOR SHALL JET AND THOROUGHLY FLUSH EXISTING SANITARY SEWERS WHERE DOCUMENTS CALL FOR NEW WASTE PIPE CONNECTIONS.3.ALL UNDERGROUND SANITARY OR STORM PIPING SHOWN TO BE ABANDONED IN PLACE SHALL BE CAPPED AND FILLED WITH FLOWABLE FILL.4.WHERE PLUMBING FIXTURE ROUGH-IN PIPING IS SHOWN TO BE ABANDONED IN WALLS OR BELOW FLOOR SLAB, ROUGH-INS SHALL BE REMOVED TO A POINT BEYOND THE FINISHED SURFACE AND CAPPED. PATCH SURFACE TO MATCH EXISTING FINISH.5.IN AREAS WHERE A FULL REMODEL IS INDICATED ON THE DRAWINGS, CONTRACTOR SHALL REMOVE ALL OVERHEAD PIPING AND HANGERS COMPLETE UNLESS OTHERWISE INDICATED.6.WHERE SANITARY OR ACID VENT THROUGH ROOF IS SHOWN TO BE ABANDONED IN PLACE, CONTRACTOR SHALL PERMANENTLY CAP PIPE ABOVE AND BELOW ROOF FOR A WATER TIGHT SEAL.PLUMBING RENOVATION NOTESN123456ABCDE123456ABCDEProject No.Project DateProducedThese Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect.KEY PLANBA5/22/2023 6:05:52 PMC:\_RevitLocal\2023-067.POR_Bldg001_P_2023\2023-067.POR_Bldg001_P_2023_jbaughman.rvt2023-067.POR05.22.2023LEVEL 1 PLUMBINGPLANS -UNIT APP1A1Designer JJBCoram DeoAcademyPhase OneRenovations2023-067.POR_Coram Deo Academy_Phase One Renovations_525 Congressional Blvd,Carmel, IN 46032PP1A1_ LEVEL 1 PLUMBING PLANS -UNIT A1/8" = 1'-0"2ALEVEL 1 PLUMBING PLANS -ART ROOMPLUMBING PLAN NOTES#NOTE1EXISTING ROUTING IS PRESUMED. CONTRACTOR TO VERIFY IN FIELD ANDCONNECT NEW DOMESTIC HW, CW, AND SANITARY VENT PIPING TO EXISTING OFEQUAL OR LARGER SIZES.PIPE2PATCH WALL AND MATCH EXISTING FINISH.3EXISTING ROUTING IS PRESUMED. CONTRACTOR TO VERIFY IN FIELD ANDCONNECT NEW DOMESTIC HW, CW, HWR, AND GAS PIPING TO EXISTING OF EQUALOR LARGER SIZES PIPE.PLUMBING FIXTURE ROUGH-IN LEGENDMARKFIXTURE CONNECTIONCWHWWVEWES-1FD-13"SK-1SK-21/2"1/2"1 1/2"1 1/2"SK-31/2"1/2"1 1/2"1 1/2"#RevisionDate T1.EXISTING PIPE ROUTING, AS SHOWN ON DRAWINGS, IS BASED UPON RECORD DOCUMENTS AND FIELD SURVEYS. ACTUAL ROUTE OF CONCEALED PIPING MAY VARY. CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY PIPE ROUTING PRIOR TO SAW CUTTING OF FLOOR SLABS.2.CONTRACTOR SHALL JET AND THOROUGHLY FLUSH EXISTING SANITARY SEWERS WHERE DOCUMENTS CALL FOR NEW WASTE PIPE CONNECTIONS.3.ALL UNDERGROUND SANITARY OR STORM PIPING SHOWN TO BE ABANDONED IN PLACE SHALL BE CAPPED AND FILLED WITH FLOWABLE FILL.4.WHERE PLUMBING FIXTURE ROUGH-IN PIPING IS SHOWN TO BE ABANDONED IN WALLS OR BELOW FLOOR SLAB, ROUGH-INS SHALL BE REMOVED TO A POINT BEYOND THE FINISHED SURFACE AND CAPPED. PATCH SURFACE TO MATCH EXISTING FINISH.5.IN AREAS WHERE A FULL REMODEL IS INDICATED ON THE DRAWINGS, CONTRACTOR SHALL REMOVE ALL OVERHEAD PIPING AND HANGERS COMPLETE UNLESS OTHERWISE INDICATED.6.WHERE SANITARY OR ACID VENT THROUGH ROOF IS SHOWN TO BE ABANDONED IN PLACE, CONTRACTOR SHALL PERMANENTLY CAP PIPE ABOVE AND BELOW ROOF FOR A WATER TIGHT SEAL.PLUMBING RENOVATION NOTES667788559CDEE101011111212HHJKLFGE.PE.P3FCO1 1/2" TW1 1/2" TW1 1/2" TW1 1/2" TWTMV-11 1/4" CW1 1/4" HW1/2" G (6 in-wc)1/2" G (6 in-wc)1/2" CW1/2" HW3/4" G (6 in-wc)1" CW3/4" HW4GSV-1GPR-151/2" CW1/2" HW1 1/2" V63" V3" VGT-1SK-2GT-2SK-32" VGT-1SK-2GT-1SK-2GT-1SK-2FCOEWES-1MGP-1RPB-11.DISTANCE BETWEEN GENERATOR AND PRESSURE REGULATOR TO BE MIN. 10 PIPE DIAMETERS OR AS DIRECTED BY INSTALLATION MANUAL.NATURAL GAS GENERAL NOTEN123456ABCDE123456ABCDEProject No.Project DateProducedThese Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect.KEY PLANBA5/22/2023 6:04:32 PMC:\_RevitLocal\2023-067.POR_Bldg001_P_2023\2023-067.POR_Bldg001_P_2023_jbaughman.rvt2023-067.POR05.22.2023LEVEL 1 PLUMBINGPLANS -UNIT A -ALTERNATEPP1A2Designer JJBCoram DeoAcademyPhase OneRenovations2023-067.POR_Coram Deo Academy_Phase One Renovations_525 Congressional Blvd,Carmel, IN 46032PP1A2_ LEVEL 1 PLUMBING PLANS -UNIT A -ALTERNATEPLUMBING PLAN NOTES#NOTE1EXISTING ROUTING IS PRESUMED. CONTRACTOR TO VERIFY IN FIELD ANDCONNECT NEW DOMESTIC HW, CW, AND SANITARY VENT PIPING TO EXISTING OFEQUAL OR LARGER SIZES.PIPE2PATCH WALL AND MATCH EXISTING FINISH.3EXISTING ROUTING IS PRESUMED. CONTRACTOR TO VERIFY IN FIELD ANDCONNECT NEW DOMESTIC HW, CW, HWR, AND GAS PIPING TO EXISTING OF EQUALOR LARGER SIZES PIPE.1/8" = 1'-0"2ALEVEL 1 PLUMBING PLANS -SCIENCE LABPLUMBING FIXTURE ROUGH-IN LEGENDMARKFIXTURE CONNECTIONCWHWWVEWES-1FD-13"SK-1SK-21/2"1/2"1 1/2"1 1/2"SK-31/2"1/2"1 1/2"1 1/2"#RevisionDate 1.EXISTING PIPE ROUTING, AS SHOWN ON DRAWINGS, IS BASED UPON RECORD DOCUMENTS AND FIELD SURVEYS. ACTUAL ROUTE OF CONCEALED PIPING MAY VARY. CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY PIPE ROUTING PRIOR TO SAW CUTTING OF FLOOR SLABS.2.CONTRACTOR SHALL JET AND THOROUGHLY FLUSH EXISTING SANITARY SEWERS WHERE DOCUMENTS CALL FOR NEW WASTE PIPE CONNECTIONS.3.ALL UNDERGROUND SANITARY OR STORM PIPING SHOWN TO BE ABANDONED IN PLACE SHALL BE CAPPED AND FILLED WITH FLOWABLE FILL.4.WHERE PLUMBING FIXTURE ROUGH-IN PIPING IS SHOWN TO BE ABANDONED IN WALLS OR BELOW FLOOR SLAB, ROUGH-INS SHALL BE REMOVED TO A POINT BEYOND THE FINISHED SURFACE AND CAPPED. PATCH SURFACE TO MATCH EXISTING FINISH.5.IN AREAS WHERE A FULL REMODEL IS INDICATED ON THE DRAWINGS, CONTRACTOR SHALL REMOVE ALL OVERHEAD PIPING AND HANGERS COMPLETE UNLESS OTHERWISE INDICATED.6.WHERE SANITARY OR ACID VENT THROUGH ROOF IS SHOWN TO BE ABANDONED IN PLACE, CONTRACTOR SHALL PERMANENTLY CAP PIPE ABOVE AND BELOW ROOF FOR A WATER TIGHT SEAL.PLUMBING RENOVATION NOTES667788553" VTRN123456ABCDE123456ABCDEProject No.Project DateProducedThese Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect.KEY PLANBA5/22/2023 6:04:42 PMC:\_RevitLocal\2023-067.POR_Bldg001_P_2023\2023-067.POR_Bldg001_P_2023_jbaughman.rvt2023-067.POR05.22.2023ROOF LEVEL PLUMBINGPLAN -ALTERNATEPR101Designer JJBCoram DeoAcademyPhase OneRenovations2023-067.POR_Coram Deo Academy_Phase One Renovations_525 Congressional Blvd,Carmel, IN 46032PR101_ ROOF LEVEL PLUMBING PLAN -ALTERNATEROOF PLUMBING PLAN NOTES#NOTE1231/8" = 1'-0"2AROOF PLUMBING PLANSPLUMBING FIXTURE ROUGH-IN LEGENDMARKFIXTURE CONNECTIONCWHWWVEWES-1FD-13"SK-1SK-21/2"1/2"1 1/2"1 1/2"SK-31/2"1/2"1 1/2"1 1/2"#RevisionDate 1.EXISTING PIPE ROUTING, AS SHOWN ON DRAWINGS, IS BASED UPON RECORD DOCUMENTS AND FIELD SURVEYS. ACTUAL ROUTE OF CONCEALED PIPING MAY VARY. CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY PIPE ROUTING PRIOR TO SAW CUTTING OF FLOOR SLABS.2.CONTRACTOR SHALL JET AND THOROUGHLY FLUSH EXISTING SANITARY SEWERS WHERE DOCUMENTS CALL FOR NEW WASTE PIPE CONNECTIONS.3.ALL UNDERGROUND SANITARY OR STORM PIPING SHOWN TO BE ABANDONED IN PLACE SHALL BE CAPPED AND FILLED WITH FLOWABLE FILL.4.WHERE PLUMBING FIXTURE ROUGH-IN PIPING IS SHOWN TO BE ABANDONED IN WALLS OR BELOW FLOOR SLAB, ROUGH-INS SHALL BE REMOVED TO A POINT BEYOND THE FINISHED SURFACE AND CAPPED. PATCH SURFACE TO MATCH EXISTING FINISH.5.IN AREAS WHERE A FULL REMODEL IS INDICATED ON THE DRAWINGS, CONTRACTOR SHALL REMOVE ALL OVERHEAD PIPING AND HANGERS COMPLETE UNLESS OTHERWISE INDICATED.6.WHERE SANITARY OR ACID VENT THROUGH ROOF IS SHOWN TO BE ABANDONED IN PLACE, CONTRACTOR SHALL PERMANENTLY CAP PIPE ABOVE AND BELOW ROOF FOR A WATER TIGHT SEAL.PLUMBING RENOVATION NOTES6" LONG HARDWOOD BLOCK SHAPED TO PIPE AND HANGERINSULATIONPIPEPIPEINSULATIONHEAVY DUTYCLEVIS HANGERSUPPORT NUTLOCKING NUTHANGER ROD14 GUAGE ZINC COATED SHEET STEEL SADDLE, AT LEAST 6" LONGN123456ABCDE123456ABCDEProject No.Project DateProducedThese Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect.KEY PLANBA5/22/2023 6:04:51 PMC:\_RevitLocal\2023-067.POR_Bldg001_P_2023\2023-067.POR_Bldg001_P_2023_jbaughman.rvt2023-067.POR05.22.2023PLUMBING DETAILS ANDSCHEDULESP-501Designer JJBCoram DeoAcademyPhase OneRenovations2023-067.POR_Coram Deo Academy_Phase One Renovations_525 Congressional Blvd,Carmel, IN 46032P-501_ PLUMBING DETAILS AND SCHEDULESEMERGENCY PLUMBING FIXTURE SCHEDULE (224500)IDENTITY DATAFIXTURE CONNECTIONMOUNTINGNOTESMARKMANUFACTURERMODELDESCRIPTIONTWVEWES-1Guardian Equipment#GBF2360RECESSED SAFETY STATION WITH DRAIN PAN, SHOWER HEAD, FIRE RATED CONSTRUCTIONCOMMERCIAL SINK SCHEDULE (224216.16)IDENTITY DATAFAUCETFIXTURE CONNECTIONMOUNTINGADACOMPLIANTNOTESMARKMANUFACTURERMODELDESCRIPTIONMANUFACTURERMODELCWHWWVSK-1MUSTEE#18FFLOOR MOUNTED UTILITY TUBCHICAGO FAUCETS#786-HR8AE3V317XKABSK-2N/AN/AINTEGRAL EPOXY SINK BY INTERIORSCHICAGO FAUCETS#LWM1-A11-F1/2"1/2"1 1/2"1 1/2"COUNTER MOUNTEDNoSK-3N/AN/AINTEGRAL EPOXY SINK BY INTERIORSCHICAGO FAUCETS#LWM1-A13-F1/2"1/2"1 1/2"1 1/2"COUNTER MOUNTEDYesSANITARY WASTE PIPING SPECIALTIES SCHEDULE (221319)IDENTITY DATAWCONNECTIONNOTESMARKMANUFACTURERMODELDESCRIPTIONFD-1J.R. SMITH#2005YA-U-PBDUCO CAST IRON BODY WITH FLASHING COLLAR, ADJUSTABLE ROUND STRAINER HEAD, POLISHED BRONZE STRAINER3"TRAPGUARD BY PROSET. NO SUBSTITUTIONS.GAS ACCESSORIESMARKMANUFACTURERMODELDESCRIPTIONNOTESGSV-1ISIMET#S-302-VA-111-UGAS SOLENOID VALVE - 24V COILWIRE TO MASTER GAS CONTROL PANELMGP-1ISIMET#LAV2-LV-K-S-GMASTER GAS CONTROL PANELRPB-1ISIMET#IP-0REMOTE PANIC BUTTONWIRE TO MASTER GAS SOLENOID ASSEMBLYGAS PRESSURE REGULATORSMARKDESCRIPTIONINLETPRESSUREOUTLETPRESSURETOTALCONNECTED LOAD(BTU/H)EQUIPMENT SERVEDGPR-1GAS PRESSURE REGULATOR2 PSI6" W.C.30000SCIENCE LAB GAS TURRETSMIXING, METERING, AND PRESSURE REDUCING VALVES (221119)IDENTITY DATANOTESMARKMANUFACTURERMODELDESCRIPTIONFLOW RATEPRESSURE DROP33GUARDIANNRS-13THERMOSTATIC MIXING VALVE, 50 GALLON CAPACITYGAS TURRETSIDENTITY DATAGASCONNECTIONMARKMANUFACTURERMODELDESCRIPTIONGT-1CHICAGO FAUCET#LGN1-A11C-10(1) OUTLET, REMOVABLE SERRATED NOZZLE, INTEGRAL CHECK VALVE, GAS INDICATOR BUTTON, VANDAL RESISTANT VALVE, CHROME PLATED WITH ANTI-ROTATION PIN1/2"GT-2CHICAGO FAUCET#LGB1-11C-10(1) OUTLET, REMOVABLE SERRATED NOZZLE, INTEGRAL CHECK VALVE, GAS INDICATOR BUTTON, VANDAL RESISTANT VALVE, CHROME PLATED WITH ANTI-ROTATION PIN1/2"1/8" = 1'-0"1CPIPE HANGER (6" & SMALLER) DETAIL#RevisionDate 1.EXISTING PIPE ROUTING, AS SHOWN ON DRAWINGS, IS BASED UPON RECORD DOCUMENTS AND FIELD SURVEYS. ACTUAL ROUTE OF CONCEALED PIPING MAY VARY. CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY PIPE ROUTING PRIOR TO SAW CUTTING OF FLOOR SLABS.2.CONTRACTOR SHALL JET AND THOROUGHLY FLUSH EXISTING SANITARY SEWERS WHERE DOCUMENTS CALL FOR NEW WASTE PIPE CONNECTIONS.3.ALL UNDERGROUND SANITARY OR STORM PIPING SHOWN TO BE ABANDONED IN PLACE SHALL BE CAPPED AND FILLED WITH FLOWABLE FILL.4.WHERE PLUMBING FIXTURE ROUGH-IN PIPING IS SHOWN TO BE ABANDONED IN WALLS OR BELOW FLOOR SLAB, ROUGH-INS SHALL BE REMOVED TO A POINT BEYOND THE FINISHED SURFACE AND CAPPED. PATCH SURFACE TO MATCH EXISTING FINISH.5.IN AREAS WHERE A FULL REMODEL IS INDICATED ON THE DRAWINGS, CONTRACTOR SHALL REMOVE ALL OVERHEAD PIPING AND HANGERS COMPLETE UNLESS OTHERWISE INDICATED.6.WHERE SANITARY OR ACID VENT THROUGH ROOF IS SHOWN TO BE ABANDONED IN PLACE, CONTRACTOR SHALL PERMANENTLY CAP PIPE ABOVE AND BELOW ROOF FOR A WATER TIGHT SEAL.PLUMBING RENOVATION NOTESSK-1SI-1EX. 2" W2" W1/2" HW1 1/2" VEX. 1/2" CW1/2" HW1 1/2" VEX. 1/2" CWSK-3EWES-1SK-2SK-2SK-2SK-23/4" HW1" CW1/2" CW1/2" HW1" CW3/4" HW1" CW3/4" HW1" CW3/4" HW3/4" CW1/2" HW1/2" CW3/4" CW3/4" HW3/4" CW3/4" HW3/4" CW1/2" HW1/2" CW1/2" HW1/2" CW1/2" HW1/2" CW1/2" HW1/2" CW1/2" HW1/2" CW1 1/2" TW1 1/2" TW1 1/2" TW1 1/2" TW1 1/2" TW1 1/2" TWTMV-11 1/2" TW1 1/4" CW1 1/4" HW1 1/2" TW1/2" CW1/2" HW1/2" HW1/2" CW1 1/2" TWSK-3AN-1SK-2AN-1SK-2AN-1SK-2AN-1SK-2AN-1AN-1EWES-1FD-1FCO2" W3" W3" W3" W3" W3" W2" W3" W3" W2" W2" W1 1/2" V1 1/2" W1 1/2" AW1 1/2" AW1 1/2" V2" W1 1/2" V1 1/2" V2" V1 1/2" AW1 1/2" AW1 1/2" V2" V2" V2" V3" V1 1/2" V3" VTR3" V1 1/2" AW1 1/2" AW2" W2" W2" W3" WFCO2" W2" W3" W3" W2" W3" W1 1/2" V3" W3" W2" W2" W2" W2" W2" W2" W3" W2" W3" W2" W2" WGPR-1GSV-1RPB-1MGP-11/2" G (6 in-wc)1/2" G (6 in-wc)GT-2GT-11/2" G (6 in-wc)1/2" G (6 in-wc)1/2" G (6 in-wc)1/2" G (6 in-wc)3/4" G (6 in-wc)3/4" G (6 in-wc)1/2" G (6 in-wc)3/4" G (6 in-wc)PIPE UNION3/4" G (6 in-wc)1/2" G (6 in-wc)1/2" G (6 in-wc)GT-1GT-11/2" G (6 in-wc)GT-11/2" G (6 in-wc)1/2" G (6 in-wc)1/2" G (6 in-wc)1/2" G (6 in-wc)1/2" G (6 in-wc)1/2" G (6 in-wc)1/2" G (6 in-wc)1/2" G (6 in-wc)1.DISTANCE BETWEEN GENERATOR AND PRESSURE REGULATOR TO BE MIN. 10 PIPE DIAMETERS OR AS DIRECTED BY INSTALLATION MANUAL.NATURAL GAS GENERAL NOTEN123456ABCDE123456ABCDEProject No.Project DateProducedThese Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect.KEY PLANBA5/22/2023 6:05:10 PMC:\_RevitLocal\2023-067.POR_Bldg001_P_2023\2023-067.POR_Bldg001_P_2023_jbaughman.rvt2023-067.POR05.22.2023PLUMBING ISOMETRICP-901Designer JJBCoram DeoAcademyPhase OneRenovations2023-067.POR_Coram Deo Academy_Phase One Renovations_525 Congressional Blvd,Carmel, IN 46032P-901_ PLUMBING ISOMETRICPLUMBING ISOMETRIC PLAN NOTES#NOTE1CONNECT TO FUME HOOD PER MANUFACTURERS INSTRUCTIONS.2CONNECT TO SHOWER HEAD PER MANUFACTURERS INSTRUCTIONS.3CONTRACTOR SHALL COORDINATE WITH FUME HOOD MANUFACTURER TOCONNECT AN-1 TO CUP SINK WASTE PIPING.1ADOMESTIC WATER PLUMBING ISOMETRIC -ART ROOM3ADOMESTIC WATER PLUMBING ISOMETRIC -SCIENCE LAB -ALTERNATE2DSANITARY WASTE AND VENT PLUMBING ISOMETRIC -SCIENCE LAB -ALTERNATE5DGAS AND AIR PLUMBING ISOMETRIC -SCIENCE LAB -ALTERNATE122113PLUMBING FIXTURE ROUGH-IN LEGENDMARKFIXTURE CONNECTIONCWHWWVEWES-1FD-13"SK-1SK-21/2"1/2"1 1/2"1 1/2"SK-31/2"1/2"1 1/2"1 1/2"PLUMBING FIXTURE ROUGH-IN LEGENDMARKFIXTURE CONNECTIONCWHWWVEWES-1FD-13"SK-1SK-21/2"1/2"1 1/2"1 1/2"SK-31/2"1/2"1 1/2"1 1/2"#RevisionDate ELECTRICAL LEGEND & SYMBOLS• EXIT SIGN• DIRECTIONAL ARROWS AS INDICATED• SHADING INDICATES ILLUMINATED FACE• CONNECT TO UNSWITCHED BRANCH CIRCUIT INDICATED• END / WALL / CEILING• LIGHTING FIXTURE• TYPE AS INDICATED• POLE MOUNTED LIGHT FIXTURE• TYPE AS INDICATED• EMERGENCY BATTERY WALL PACK• TYPE AS INDICATED• SHADING INDICATES EMERGENCY FIXTURE CONNECTED TO BATTERY INVERTER OR GENERATOR• CONNECT BATTERY INVERTER TO UNSWITCHED SOURCE IN ADDITION TO SWITCHING INDICATED• TRACK AND TRACK LIGHT FIXTURE• LIGHT FIXTURE• TYPE AS INDICATED• WALL MOUNTED FIXTURE• TYPE AS INDICATEDLIGHTINGSUBSCRIPTS FOR LIGHTING FIXTURES INDICATE THE FOLLOWING, U.O.N.NL -NIGHT LIGHT, PANEL SWITCHED, U.O.N.POWER DISTRIBUTION• POWER DISTRIBUTION PANELBOARD• 208Y / 120V; 3Ø, 4W• FLOOR / SURFACE• BRANCH CIRCUIT PANELBOARD• 208Y/120V OR 480Y/277V; 3Ø, 4W• FLUSH / SURFACE• TERMINAL CABINET, TYPE AS NOTED ON DRAWINGS • FLUSH / SURFACE• DRY-TYPE TRANSFORMER, RATING AS INDICATED• HOUSEKEEPING PAD• SWITCHBOARD W/MAIN CIRCUIT BREAKER SECTION• HOUSEKEEPING PAD• AUTOMATIC TRANSFER SWITCH• WORKING CLEARANCE ABOUT ELECTRICAL EQUIPMENT• ELECTRIC MANHOLE• GROUND ROD• MOTOR -"M" INDICATES HORSEPOWER• HEAVY-DUTY, NON-FUSED DISCONNECT SWITCH (DS-#)• HEAVY-DUTY, FUSED DISCONNECT SWITCH (DS-#)• COMBINATION MOTOR STARTER AND DISCONNECT SWITCH (MS-#)• VARIABLE FREQUENCY DRIVE (MS-#)• FRACTIONAL HOURSEPOWER MANUAL CONTROLLER WITH THERMAL OVERLOADS (MS-#)• EMERGENCY POWER OFF BUTTON • SIMPLEX RECEPTACLE• NEMA 5-20R, 125V, 20AWIRING DEVICESSUBSCRIPTS FOR RECEPTACLES, JUNCTION BOXES AND OTHER DEVICES INDICATE THE FOLLOWING, U.O.N:F -FLUSH IN FLOORGFCI -GROUND FAULT CIRCUIT INTERRUPTERH -HORIZONTALLY MOUNTEDIG -ISOLATED GROUNDL -LOCKING TYPETR -TAMPER RESISTANTS -SURFACE MOUNTEDWP -WEATHERPROOF IN-USEX -MOUNTED IN EXISTING OUTLET BOX• DUPLEX RECEPTACLE• NEMA 5-20R,125V, 20A• DOUBLE DUPLEX (QUADRAPLEX) RECEPTACLE• NEMA 5-20R,125V, 20A• DUPLEX RECEPTACLE• EMERGENCY CIRCUIT• NEMA 5-20R, 125V, 20A• DOUBLE DUPLEX (QUADRAPLEX) RECEPTACLE• EMERGENCY CIRCUIT• NEMA 5-20R, 125V, 20A• SPECIAL RECEPTACLE• NEMA CONFIGURATION AS INDICATED ON DRAWING• JUNCTION BOX• DIRECT CONNECTION TO EQUIPMENT• PULLBOX• PROVIDE PULLBOXES INDICATED AS A MINIMUM• PROVIDE ADDITIONAL PULLBOXES, SIZED PER NEC, AS REQUIRED• FLUSH JUNCTION BOX WITH FURNITURE FEED ADAPTING CONNECTOR MOUNTED AT 6" A.F.F.• SURFACE-MOUNTED RACEWAY• RECEPTACLES IN LOCATIONS INDICATED• WIREWAY• WALL MOUNTED U.O.N.• FLOOR BOX• SINGLE POLE SWITCH• THREE-WAY SWITCH• THREE-WAY SWITCH WITH PILOT LIGHT• FOUR-WAY SWITCH• SINGLE POLE SWITCH W/ PILOT LIGHT• KEY OPERATED SINGLE POLE SWITCH• KEY OPERATED THREE-WAY SWITCHMEMHATSJJFBMJMS-#• PUSH BUTTON CONTROL STATIONPB3P43PK3KMCBDPANELBOARD NAMING1 2 A 1BRANCH PANELBOARDSSEQUENTIAL PANEL NUMBERFLOOR PLAN UNIT A -UNIT AB -UNIT BVOLTAGE 2 -208Y/120V4 -480Y/277VFLOOR NUMBERB -BASEMENT1 -1ST FLOOR2 -2ND FLOOR1 2 A DP 1POWER DISTRIBUTION PANELBOARDSSEQUENTIAL PANEL NUMBER"DISTRIBUTION PANELBOARD"FLOOR PLAN UNIT A -UNIT AB -UNIT BVOLTAGE 2 -208Y/120V4 -480Y/277VFLOOR NUMBERB -BASEMENT1 -1ST FLOOR2 -2ND FLOORLIGHTING CONTROL DEVICESOS1O1• MANUAL CONTROLS & AUTO-ON / AUTO-OFF• 1000 SQFT COVERAGE• TWO RELAYS IN POWER PACKSYMBOLMOUNTINGWALLDIMMING TYPE0-10VOCCUPANCY SENSOR TYPESWITCH/BUTTONSCONTROL DESCRIPTION• (1) MANUAL SWITCH ON (TO SELECTED LIGHT LEVEL)/OFF• (1) MANUAL LIGHT LEVEL WITH SLIDER(1)N/ADDSWALL0-10V• (1) MANUAL SWITCH ON (TO SELECTED LIGHT LEVEL)/OFF • (1) MANUAL LIGHT LEVEL WITH SLIDER• MANUAL ON / AUTO OFF(1)DUAL TECH.DDLWALLLINE VOLT.• (1) MANUAL SWITCH ON (TO SELECTED LIGHT LEVEL)/OFF• (1) MANUAL LIGHT LEVEL WITH SLIDER(1)N/AWALLN/ADUAL TECH.(1)OS2WALLN/ADUAL TECH.(1)• (1) MANUAL SWITCH ON/OFF• MANUAL ON / AUTO OFFOS3WALLN/ADUAL TECH.(2)• (2) MANUAL SWITCH ON/OFF• MANUAL ON / AUTO OFFCEILINGN/ADUAL TECH.N/AO1• AUTO-ON / AUTO-OFF ONLY• 1000 SQFT COVERAGE• TWO RELAYS IN POWER PACKCEILINGN/ADUAL TECH.N/AO1• MANUAL CONTROLS & AUTO-ON / AUTO-OFF• 1000 SQFT COVERAGE• TWO RELAYS IN POWER PACK• PLUG-LOAD CONTROL OF RECEPTACLES INDICATED IN ROOM, U.O.N.CEILINGN/ADUAL TECH.N/ADDMXWALLDMXN/AMULTI.• DMX COLOR CHANGING CONTROLLER• NICOLAUDIE STICK-CU4O1• MANUAL CONTROLS & AUTO-ON / AUTO-OFF• TWO RELAYS IN POWER PACK• HIGHBAY COVERAGECEILINGN/APIRN/A• (1) MANUAL SWITCH ON/OFF• AUTO ON / AUTO OFFO1• DAY-LIGHT HARVESTING CONTROLLER W/AUTO DIMMINGCEILINGN/AN/AN/AAAMPEREALTERNATING CURRENT; ARMORED CABLEAMP SIZE OF CIRCUIT BREAKER FRAME/FUSED SWITCH ABOVE FINISHED COUNTERTOPARC FAULT CIRCUIT INTERRUPTERABOVE FINISHED FLOORABOVE FINISHED GRADEAIR HANDLING UNITAMPERE INTERRUPTING CAPACITYALUMINUMAMERICAN NATIONAL STANDARDS INSTITUTEASYMMETRICALAMP TRIP SIZE CIRCUIT BREAKER/FUSED SWITCH AUTOMATIC TRANSFER SWITCHAUXILIARYAVERAGEAMERICAN WIRE GAUGEBATTERYBRANCH CIRCUIT PANELBOARDBREAKERBOLTED PRESSURE SWITCHCONDUIT; CELSIUSCABINETCIRCUIT BREAKERCENTER TO CENTERCANDELACUBIC FEETCENTERLINECEILINGCONCRETE MASONRY UNITCOLUMNCOMBINATIONCONCRETECONDUCTORCONNECTIONCONTINUOUS; CONTINUEDCONSTRUCTIONCONTROL PANELCONTROL POWER TRANSFORMERCURRENT TRANSFORMERCOPPER; CONDENSING UNITCABINET UNIT HEATERCYLINDERDEEP; DEPTHDIRECT BURIEDDIRECT CURRENTDEDICATED DEVICE ON INDIVIDUAL BRANCH CIRCUITDEMOLISH; DEMOLITIONDIAMETERDIAGONALDISCONNECTDISTRIBUTIONDOWNDOUBLE-POLE, DOUBLE-THROWDOUBLE-POLE, SINGLE-THROWDISHWASHERDRAWINGEACHELECTRICAL CONTRACTOR; DIVISIONS 26-28EXHAUST FANELECTRICAL GROUND BARELECTRICAL GROUNDING CONDUCTORELECTRIC HAND DRYERELECTRICALELEVATOR; ELEVATIONEMERGENCYELECTRICAL METALLIC TUBINGENCLOSUREENGINEELECTRICALLY OPERATEDEMERGENCY POWER OFFEQUALEQUIPMENTENERGY REDUCTION MAINTENANCE SWITCHESTIMATEDEXISTING TO REMAINELECTRIC WATER COOLERELECTRIC WATER HEATEREXPOSEDEXISTINGEXTERIORFUSED; FAHRENHEITFIRE ALARMFIRE ALARM ANNUNCIATORFIRE ALARM CONTROL UNITFLOOR BOXFOOT-CANDLEFAN COIL UNITFUSED DISCONNECTFOUNDATIONFEEDERFINISHEDFIXTUREFULL LOAD AMPSFLEXIBLEFLOORFACTORY MUTUALFLEXIBLE METAL CONDUITFAN POWERED BOXFEED THROUGH LUGSFEET; FOOTFEED THROUGH LUGSFURNISHEDFULL VOLTAGE NON-REVERSINGGROUNDGAUGEGALVANIZEDGENERAL CONTRACTORGARBAGE DISPOSALGENERATORGROUND FAULT EQUIPMENT PROTECTIONGROUND FAULT CIRCUIT INTERRUPTERHIGHHEAVY DUTYHIGH-DENSITY POLYETHYLENE CONDUITHAND-OFF-AUTOHORIZONTALHORSEPOWERHRHTHEAT PUMPHEATERHERTZINSIDE DIAMETERINSTIT. OF ELECTRICAL AND ELECTRONICS ENGINEERSISOLATED GROUNDINTERMEDIATE METAL CONDUITIMPEDANCEACAFAFCAFCIAFFAFGAHUAICALANSIASYMATATSAUXAVGAWGBATTBCPBKRBPSCCABCBC/CCDCFCLCLGCMUCOLCOMBCONCCONDCONNCONTCONSTCPCPTCTCUCUHCYLDDBDCDEDDEMODIADIAGDISCDISTRDNDPDTDPSTDWDWGEAECEFEGBEGCEHDELECELEVEMEMTENCLENGEOEPOEQEQUIPERMESTETREWCEWHEXPEXEXTFFAFAAFACUFBFCFCUFDFDNFDRFINFIXTFLAFLEXFLRFMFMCFPBFTLFTFTLFURNFVNRG/GNDGAGALVGCGDGENGFEPGFCIHHDHDPEHOAHORIZHPHRHTHTPHTRHZIDIEEEIGIMCIMPABBREVIATIONSININCHINSULATED; INSULATIONINTERIOR; INTERNALINVERTED ELEVATIONJOULEJUNCTION BOXTHOUSANDTHOUSAND CIRCULAR MILSKIRK KEYKNOCKOUTKEYPADKILOVOLTSKILOVOLT-AMPERESKILOVOLT-AMPERES REACTIVEKILOWATTSLINEAR FEETLENGTH; LONGLIGHTNING ARRESTORLIGHT EMITTING DIODELIQUIDTIGHT FLEXIBLE METAL CONDUITLUMENLOCK-OUT TAG-OUTLOCKED ROTOR AMPSLONG-SHORT-INSTANTANEOUSLONG-SHORT-INSTANTANEOUS-GROUND FAULTLIGHT; LIQUIDTIGHTLIGHTINGLOW VOLTAGEMANUALMATERIALMAXIMUMMECH. CONTRACTOR (DIV. 23); METAL CLAD CABLEMINIMUM CIRCUIT AMPACITYMAIN CIRCUIT BREAKERMOTOR CONTROL CENTERMOLDED CASE CIRCUIT BREAKERMAIN DISTRIBUTION PANELBOARDMECHANICALMANUFACTURINGMANUFACTURERMANHOLE; MOUNTING HEIGHTMINIMUMMISCELLANEOUSMAIN LUGS ONLYMAXIMUM OVERCURRENT PROTECTIONMAIN SWITCHBOARDMOUNTEDMOUNTINGMANUAL TRANSFER SWITCHMEDIUM VOLTAGEMEGAVOLT AMPERESMEGAVOLT AMPERES REACTIVENEUTRALNOT APPLICABLENORMALLY CLOSEDNEGATIVE (-)NATIONAL ELECTRICAL MANUFACTURERS ASSOC.NON-FUSED DISCONNECT SWITCHNIGHT LIGHTNON-METALLIC SHEATHED CABLENORMALLY OPEN; NUMBERNOT TO SCALEINSULINTINV ELJJBKKCMILKKKOKPKVKVAKVARKWLFLLALEDLFMCLMLOTOLRALSILSIGLTLTGLVMANMATMAXMCMCAMCBMCCMCCBMDPMECHMFGMFRMHMINMISCMLOMOCPMSBMTDMTGMTSMVMVAMVARNN/ANCNEGNEMANFNICNLNMNONTSKILOWATT-HOURSKWHRPOUNDLBLIGHTING CONTROL RELAY PANELLCPMEDIUMMEDMEGAWATTS; MICROWAVE OVENMWMAIN ELECTRICAL GROUND BARMEGBNOT IN CONTRACTOCODOHOLPPBPCPEDPFPH/ØPLPOSPRIPSFPSIPTPUHPVCPWRQTYRREFREFRREQ'DRLARMCRMRTRTURVATSCCRSCHEDSCRSECSFSFBSFLSNSPSPDTSPECSPSTSQSQ FTSQ INSSS/SSTSTDSTPSURFSWSWBDPIVRECEPTSPDSQ YDSYMTTBTCCTCPTRTSTYPUCUGULUNFINUNOVERTUTPUVVARVFDVGVIFVMVPVRVUVWW/W/OWGWPWTXFERXFMRYUTILVVATCTDOVERCURRENTOUTSIDE DIAMETEROVERHEADOVERLOADPOLEPULL BOX; PUSH BUTTONPHOTOCELL; PLUMBING CONTRACTOR (DIVISION 22)PEDESTALPOWER FACTORPHASEPILOT LIGHTPOSITIVE (+)PRIMARYPOUNDS PER SQUARE FOOTPOUNDS PER SQUARE INCHPOTENTIAL TRANSFORMERPROPELLER UNIT HEATERPOLYVINYL CHLORIDE CONDUITPOWERQUANTITYRESISTANCEREFERENCEREFRIGERATORREQUIREDRUNNING LOAD AMPSRIGID METAL CONDUITROOMRAINTIGHTROOF TOP UNITREDUCED VOLTAGE AUTOTRANSFORMERSHORT-CIRCUIT CURRENT RATINGSCHEDULESHORT CIRCUIT RATINGSECONDARYSUPPLY FANSUB-FEED CIRCUIT BREAKERSUB-FEED LUGSSOLID NEUTRALSINGLE-POLESINGLE-POLE, DOUBLE-THROWSPECIFICATIONSINGLE-POLE, SINGLE-THROWSQUARESQUARE FEETSQUARE INCHSTAINLESS STEELSTART-STOPSHUNT TRIPSTANDARDSHIELDED TWISTED PAIRSURFACESWITCHSWITCHBOARDPOST INDICATOR VALVERECEPTACLESURGE PROTECTION DEVICESQUARE YARDSYMMETRICALTEMPERATURE; TRANSFORMERTERMINAL BLOCKTEMPERATURE CONTROL CONTRACTORTEMPERATURE CONTROL PANELTAMPER-RESISTANTTAMPER SWITCHTYPICALUNDERCOUNTER; UNDERCABINETUNDERGROUNDUNDERWRITERS LABORATORYUNFINISHEDUNLESS NOTED OTHERWISEVERTICALUNSHIELDED TWISTED PAIRUNIT VENTILATORVOLT AMPERES REACTIVEVARIABLE FREQUENCY DRIVEVANDAL GUARDVERIFY IN FIELDVENDING MACHINEVANDAL PROOFVANDAL RESISTANTVERTICAL UNIT VENTILATORWIDE; WIRE; WATTWITHWITHOUTWIRE GUARDWEATHERPROOFWATERTIGHT; WEIGHTTRANSFERTRANSFORMERWYEUTILITYVOLTVOLT AMPERESTIME CLOCKTIME DELAY• DUPLEX RECEPTACLE• SPLIT-WIRE• NEMA 5-20R, 125V, 20A• DUPLEX RECEPTACLE• PLUG-LOAD CONTROLLED• NEMA 5-20R, 125V, 20A• DOUBLE DUPLEX (QUADRAPLEX) RECEPTACLE• PLUG-LOAD CONTROLLED• NEMA 5-20R, 125V, 20AHALF CONTROLLEDFULLY CONTROLLEDCONDUIT & FEEDER• OVERHEAD ELECTRICAL SERVICE• UNDERGROUND ELECTRICAL SERVICE• CONDUIT -TURNED UP• CONDUIT -TURNED DOWN• HOMERUN TO PANEL WITH CIRCUIT NUMBER(S) AS INDICATED• GROUND CONDUCTOR• PHASE CONDUCTOR• NEUTRAL CONDUCTOR• ONE-LINE DIAGRAM• EXISTING FEEDER & CONDUIT• ONE-LINE DIAGRAM• DEMOLISHED FEEDER & CONDUIT• ONE-LINE DIAGRAM• NEW (NORMAL) FEEDER & CONDUIT• ONE-LINE DIAGRAM• NEW (EMERGENCY) FEEDER & CONDUIT• ONE-LINE DIAGRAM & FLOOR PLANS• NEW FEEDER & CONDUIT SIZE• REFER TO 'FEEDER & BRANCH CIRCUIT SCHEDULE (COPPER)' OR 'FEEDER SCHEDULE (ALUMINUM)' BASED ON SPECIFICATIONS AND PROVIDE BOTH FEEDER AND CONDUIT SIZE INDICATEDF###• FIRE ALARM CONTROL UNIT• FLUSH / SURFACEFIRE ALARM SYSTEMSUBSCRIPTS FOR FIRE ALARM SYSTEM DEVICES INDICATE THE FOLLOWING, U.O.N:S -SURFACE MOUNTEDWP -WEATHERPROOFX -MOUNTED IN EXISTING OUTLET BOX• REMOTE FIRE ALARM CONTROL UNIT• FLUSH / SURFACE• FIRE ALARM ANNUNCIATOR UNIT• FLUSH / SURFACE• MANUAL PULL STATION• SPEAKER• WALL / CEILING• VISUAL STROBE• WALL / CEILING• BELL WITH VISUAL INDICATOR• WALL• DUCT DETECTOR -SUPPLY DUCT• DUCT DETECTOR -RETURN DUCT• DOOR HOLD RELEASE DEVICE• SUPPLIED BY DIVISION 8• SPRINKLER SYSTEM TAMPER SWITCH• SPRINKLER SYSTEM FLOW SWITCH• POST INDICATOR VALVE• SPEAKER/STROBE• WALL / CEILING• HORN• WALL / CEILINGMSSHHVBRTSFSPSFRFSDRDFACUFACURACURACUFAAFAAAR• ADDRESSABLE RELAY MODULE FOR CONTROL / MONITORING• SPRINKLER SYSTEM PRESSURE SWITCHPS• HORN/STROBE• WALL / CEILING• SMOKE DETECTOR• CEILING• HEAT DETECTOR• CEILINGSRF• COMBINATION SMOKE / HEAT DETECTOR• CEILINGVVVVV• POWER DISTRIBUTION PANELBOARD• 480Y / 277V; 3Ø, 4W• FLOOR / SURFACEHALF CONTROLLEDFULLY CONTROLLEDSYMBOLMOUNTING HEIGHT ABOVE FINISHED FLOOR (U.O.N.)• +18" TO CENTER OF RECEPTACLE• +6" ABOVE TOP OF COUNTERTOP TO BOTTOM OF RECEPTACLE• +46" TO CENTER OF LIGHT SWITCH / CONTROLSSO1, SO2, SO3,3, 4, P, 3P, K, 3KD• +46" TO CENTER OF DIMMER / CONTROLSD1, D2, D3, DMX• COORDINATE MOUNTING HEIGHT WITH EQUIPMENT IF NOT INDICATED ON DRAWING• +46" TO CENTER OF MOTOR STARTER TOGGLE SWITCHMS• +46" TO CENTER OF EMERGENCY SHUT-OFFBHHSSV• +80" TO BOTTOM OF WALL MOUNTED FIRE ALARM DEVICEM• +46" TO CENTER OF MANUAL PULL STATION• REFER TO SPECIFICATIONS AND 'GENERAL SYMBOLS & ABBREVIATIONS NOTES (ALL DRAWINGS)'• +90" TO TOP OF POWER DISTRIBUTION PANELBOARD'S TRIM• +72" TO TOP OF PANELBOARD'S TRIM• +72" TO TOP OF EQUIPMENT• +72" TO TOP OF EQUIPMENT• +18" TO CENTER OF RECEPTACLE• +6" ABOVE TOP OF COUNTERTOP TO BOTTOM OF RECEPTACLE• FLUSH TO CEILINGMOUNTING HEIGHTSANNOTATION SYMBOLS• CIRCUIT TAGPANEL-CKT• ROOM CIRCUIT TAGPANEL-CKTFLOW SWITCHFSMAIN FUSED SWITCHMFSN123456ABCDE123456ABCDEProject No.Project DateProducedThese Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect.KEY PLANBA5/22/2023 10:16:41 AMC:\_RevitLocal\2023-067.POR_Bldg001_E_2023\2023-067.POR_Bldg001_E_2023_smathis.rvt2023-067.POR05.22.2023SYMBOLS &ABBREVIATIONSE-001SACM JNSCoram DeoAcademyPhase OneRenovations2023-067.POR_Coram Deo Academy_Phase One Renovations_525 Congressional Blvd,Carmel, IN 46032E-001_ SYMBOLS & ABBREVIATIONSGENERAL ROUGH-IN MOUNTING HEIGHTNOTES#NOTESACOMPLETE COMPLIANCE WITH ALL ASPECTS OF ADA STANDARDS FORACCESSIBLE DESIGN AND ICC/ANSI A117.1 IS REQUIRED OF ALL PROJECTS ANDACTIVITIES.BMOUNTING HEIGHTS INDICATED ARE FOR TYPICAL DEVICES, UNLESS NOTED ORSPECIFIED OTHERWISE.CCOORDINATE MOUNTING HEIGHTS OF ANY DEVICES WHICH ARE NOT INDICATEDBY ARCHITECT OR AND/OR ENGINEER.DREFERENCE DIVISIONS 8, 10, 14, 22, 23, AND 27 FOR ADDITIONAL MOUNTINGHEIGHTS.#RevisionDate CONDUCTOR SIZESINGLE PHASEMAXIMUM BRANCH CIRCUIT CONDUCTOR LENGTHS (FEET)#12#8#6#4#3#2#1BRANCH CIRCUIT BREAKER SIZE#10120 VOLT5520A-1P30A-1P95145230355440540660N/A6595150235290360440208 VOLT10020A-2P30A-2P1652554006207609351145N/A110170265415505625765277 VOLT13520A-1P30A-1P220340535825101512501525N/A1452253555506758301020480 VOLT23020A-2P30A-2P3855909251435175521652650N/A255390615955117014401765CONDUCTOR SIZETHREE PHASE#12#8#6#4#3#2#1BRANCH CIRCUIT BREAKER SIZE#10208 VOLT11520A-3P30A-3P19029546071588010801325N/A125195305475585720880480 VOLT27020A-3P30A-3P44568010701655203025003060N/A2954557101105135016652040NOTES:1. MAINTAIN A MAXIMUM VOLTAGE DROP OF 3%. ADJUST CONDUCTOR SIZE PER MAXIMUM BRANCH CIRCUIT LENGTH.2. BRANCH CIRCUIT LENGTHS ARE BASED ON CONDUCTOR DISTANCE FROM PANELBOARD TO LOAD.3. PROVIDE JUNCTION BOX TO MAKE WIRE TRANSITION FOR FINAL TERMINATION ON DEVICE, FIXTURE, EQUIPMENT, ETC.4. CALCULATIONS BASED ON COPPER CONDUCTORS, 80% LOADING OF BRANCH CIRCUIT BREAKER, AND 0.95 POWER FACTOR.F2012123/4"1P,1N,1G2P,1G2P,1N,1G3P,1G3P,1N,1G3P,1NEQUIP/SERV GROUNDFEEDER/BRANCH CIRCUIT LABELCONDUCTOR SIZE PER CONDUITCONDUIT SIZE & QUANTITYFEEDER & BRANCH CIRCUIT SCHEDULE (COPPER)3P,2N,1G3P,3N,1G3P,1N,2GPHASE & NEUTRAL3/4"3/4"3/4"3/4"3/4"F3010103/4"3/4"3/4"3/4"3/4"3/4"F408103/4"3/4"1"1"1"1"F506101"1"1"1-1/4"1-1/4"1"F604101"1"1-1/4"1-1/4"1-1/4"1-1/4"F70481"1-1/4"1-1/4"1-1/4"1-1/2"1-1/4"F80381"1-1/4"1-1/4"1-1/2"1-1/2"1-1/4"F90281"1-1/4"1-1/2"1-1/2"2"1-1/2"F100181-1/4"1-1/2"1-1/2"2"2"2"F110161-1/4"1-1/2"2"2"2-1/2"2"F1251/061-1/4"1-1/2"2"2"2-1/2"2"F1501/061-1/4"1-1/2"2"2"2-1/2"2"F1752/061-1/2"2"2"2-1/2"2-1/2"2"F2003/061-1/2"2"2"2-1/2"3"2-1/2"F2254/042"2"2-1/2"3"2-1/2"F25025042"2-1/2"3"3"3"F30035042"2-1/2"3"3-1/2"3"F35050032-1/2"3"3-1/2"4"3-1/2"F4003/03(2) 1-1/2"(2) 2"(2) 2-1/2"(2) 2-1/2"(2) 2-1/2"F4504/02(2) 2"(2) 2"(2) 2-1/2"(2) 3"(2) 2-1/2"F5002502(2) 2"(2) 2-1/2"(2) 3"(2) 3"(2) 3"F6003501(2) 2-1/2"(2) 3"(2) 3"(2) 3-1/2"(2) 3"F7005001/0(2) 2-1/2"(2) 3"(2) 3-1/2"(2) 4"(2) 3-1/2"F8003502/0(3) 2-1/2"(3) 3"(3) 3"(3) 3-1/2"(3) 3"F9003502/0(3) 2-1/2"(3) 3"(3) 3"(3) 3-1/2"F10005002/0(3) 2-1/2"(3) 3"(3) 3-1/2"(3) 4"F12003503/0(4) 2-1/2"(4) 3"(4) 3"(4) 3-1/2"F16005004/0(5) 3"(5) 3"(5) 3-1/2"(5) 4"F2000500250(6) 3"(6) 3"(6) 3-1/2"(6) 4"F2500500350(7) 4"(7) 3-1/2"(7) 3-1/2"(7) 4"F3000500500(8) 4"(8) 4"(8) 4"N123456ABCDE123456ABCDEProject No.Project DateProducedThese Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect.KEY PLANBA5/22/2023 10:17:07 AMC:\_RevitLocal\2023-067.POR_Bldg001_E_2023\2023-067.POR_Bldg001_E_2023_smathis.rvt2023-067.POR05.22.2023GENERAL INFORMATIONE-002SACM JNSCoram DeoAcademyPhase OneRenovations2023-067.POR_Coram Deo Academy_Phase One Renovations_525 Congressional Blvd,Carmel, IN 46032E-002_ GENERAL INFORMATIONGENERAL FEEDER & BRANCH CIRCUITSCHEDULE NOTES (COPPER & ALUMINUM)#NOTESAPROVIDE BOTH NEW CONDUCTORS AND NEW CONDUIT FOR ALL FEEDERS ANDBRANCH CIRCUITS INDICATED WITH A 'FEEDER/BRANCH CIRCUIT LABEL'. DO NOTREUSE ANY EXISTING CONDUCTORS AND/OR CONDUIT UNLESS SPECIFICALLYNOTED ON DRAWINGS, ONE-LINE DIAGRAM, ETC.BREFER TO SPECIFICATIONS FOR MINIMUM CONDUCTOR AND CONDUIT SIZES.CREFER TO SPECIFICATIONS FOR TYPE OF RACEWAY.DFOR ALL NEW AND EXISTING CONDUIT INSTALLATIONS, REFER TO THE NEC FORCONDUIT AND TUBING FILL TABLES. IN LOCATIONS WHERE EXISTING CONDUIT ISPERMITTED TO BE REUSED, IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFYTHE EXISTING CONDUIT SIZE MEETS THE NEC CONDUIT AND FILL TABLES PRIORTO BID. IF THE CONDUIT DOES NOT MEET THE NEC FILL TABLES, REPLACE THECONDUIT FOR THE FEEDER AND/OR BRANCH CIRCUIT IN IT'S ENTIRETY TOSATISFY THE NEC CONDUIT AND TUBING FILL TABLES.EANY CONDUIT AND/OR CONDUCTOR SIZE DEVIATIONS FROM THIS SCHEDULE, ORINDICATED ON DRAWINGS, MUST BE APPROVED BY THE ENGINEER IN WRITING.GENERAL REQUIREMENTS NOTES(ALL DRAWINGS)#NOTESAAPPLICABLE CODES:- 2009 INDIANA ELECTRICAL CODE (2008 NEC WITH AMMENDMENTS)- NFPA 72 - 2010BCONNECT ALL LIGHTING FIXTURES WITHIN ROOM TO INDICATED SWITCH ANDBRANCH CIRCUIT, U.O.N.CWHERE MULTIPLE SWITCHES, RECEPTACLES, AND OTHER OUTLETS (EXCEPTPHONES) ARE INDICATED, PROVIDE MULTI-GANGEBACK OUTLET BOXES WITHGANG BARRIERS AND A COMMON FACEPLATE FOR SIMILIAR DEVICES.DWHERE EXIT SIGNS ARE INDICATED ABOVE DOOR, MOUNT AS FOLLOWS: IF THEDISTANCE BETWEEN THE TOP OF THE DOOR FRAME AND THE CEILING IS 24INCHES OR LESS, CENTER THE EXIT SIGN BETWEEN TOP OF DOOR FRAME ANDCEILING. OTHERWISE, MOUNT BOTTOM OF EXIT SIGN 6 INCHES ABOVE TOP OFDOOR FRAME. MOUNT OTHER WALL MOUNTED EXIT SIGNS LOCATED WITHIN THESAME AREA AT THE SAME HEIGHT.EWHERE DIFFERENT RECESSED ELECTRICAL DEVICES WITH THE SAME MOUNTINGHEIGHTS ARE INDICATED SIDE-BY-SIDE, MOUNT THE DEVICES SO THAT THERE ISFOUR INCHES BETWEEN ADJACENT VERTICAL EDGES.FWHERE ELECTRICAL DEVICES WITH DIFFERENT MOUNTING HEIGHTS ARELOCATED IN THE SAME AREA ALIGN DEVICES VERTICALLY THROUGH THEIRCENTERLINES.GINSTALL SEPARATE INDEPENDENT NEUTRAL CONDUCTORS FOR ALL 120V AND277V CIRCUITS. DO NOT SHARE NEUTRALS.HALL EXIT FIXTURES AND FIXTURES INDICATED WITH "NL" SHALL BE UNSWITCHED.IINSTALL NO MORE THAN THREE PHASE CONDUCTORS (PLUS NEUTRALS ANDGROUND) PER CONDUIT UNLESS T310-15 NEC IS FOLLOWED.JNUMBER OF WIRES INDICATED ON DRAWINGS, IN PANEL SCHEDULES ANDCIRCUIT SIZING SCHEDULES APPLIES TO CURRENT CARRYING CONDUCTORSINCLUDING NEUTRALS. IN ADDITION TO THE NUMBER OF WIRES INDICATED,PROVIDE AN EQUIPMENT GROUNDING CONDUCTOR SIZED AS SCHEDULED ORSIZED BY NEC 250.KUNLESS OTHERWISE NOTED, PROVIDE FEEDERS AND BRANCH CIRCUITS WHICHHAVE AN AMPACITY EQUAL TO OR GREATER THAN THE CIRCUIT OVERCURRENTPROTECTIVE DEVICE RATING SERVING THE CIRCUIT. REFER TO CIRCUIT SIZINGSCHEDULE FOR SIZES OF FEEDERS AND BRANCH CIRCUITS.LCOORDINATE LOCATION OF CEILING MOUNTED FIRE ALARM DEVICES WITHOTHER EQUIPMENT TO AVOID INTERFERENCE. LOCATE FIRE ALARM DEVICES ASNEAR TO LOCATION INDICATED WHILE AVOIDING INTERFERENCES.MMAKE FINAL CONNECTION BETWEEN DISCONNECT AND EQUIPMENT BEINGSERVED BY FEEDER OR BRANCH CURRENT.NDIVISION 26 CONTRACTOR SHALL REFER TO LIFE SAFETY PLAN FOR FIRE-RATINGREQUIREMENTS. DIVISION 26 CONTRACTOR SHALL BE RESPONSIBLE FORPROVIDING FIRE-RATED DEVICES/SEALS AS SHOWN ON ELECTRICAL DRAWINGSAND AS REQUIRED BASED ON LIFE SAFETY PLAN INFORMATION.OPER NEC ARTICLE 110.26(A) AND 110.26(F) THE DEDICATED ELECTRICAL SPACEINCLUDES THE SPACE DEFINED BY EXTENDING THE FOOTPRINT OF THEELECTRICAL EQUIPMENT (INCLUDING BUT NOT LIMITED TO SWITCHBOARDS,PANELBOARDS, TRANSFORMERS, MOTOR CONTROLLERS) FROM THE FLOOR TO AHEIGHT OF 6’-0” ABOVE THE HEIGHT OF THE EQUIPMENT OR TO THE STRUCTURALCEILING, WHICH EVER IS LOWER. THE DEDICATED ELECTRICAL SPACE MUST BECLEAR OF ANY PIPING, DUCTS, LEAK PROTECTION APPARATUS, OR EQUIPMENTFOREIGN TO THE ELECTRICAL INSTALLATION. PLUMBING, HEATING, VENTILATION,AND AIR-CONDITIONING PIPING, DUCTS, AND EQUIPMENT MUST BE INSTALLEDOUTSIDE THE WIDTH AND DEPTH ZONE. CONTRACTOR SHALL MAKE SURE NOPIPING OR DUCT WORK IS INSTALLED ABOVE THE ELECTRICAL EQUIPMENT.COORDINATE THESE REQUIREMENTS WITH ALL OTHER TRADES PRIOR TOINSTALLATION.PCONTRACT DOCUMENTS CONSISTS OF BOTH A PROJECT MANUAL ANDDRAWINGS. BOTH ARE MEANT TO BE COMPLEMENTARY - ANYTHING APPEARINGON EITHER MUST BE EXECUTED THE SAME AS IF SHOWN ON BOTH.#RevisionDate TTTTTTHMHHMHGFCIGFCIVSJHHGFCIGFCIGFCIVVHMVMVPTVARVJARARARJJ678549A21BCDE101112HJKLFGA5A4A3A2A1E.P678549A21BCDE101112HJKLFGA5A4A3A2A1E.PL1PG1G2PNL-1N123456ABCDE123456ABCDEProject No.Project DateProducedThese Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect.KEY PLANBA5/22/2023 10:17:23 AMC:\_RevitLocal\2023-067.POR_Bldg001_E_2023\2023-067.POR_Bldg001_E_2023_smathis.rvt2023-067.POR05.22.2023OVERAL BUILDING PLANE-101SACM JNSCoram DeoAcademyPhase OneRenovations2023-067.POR_Coram Deo Academy_Phase One Renovations_525 Congressional Blvd,Carmel, IN 46032E-101_ OVERAL BUILDING PLANGENERAL OVERALL BUILDING NOTES#NOTESAREFER TO SHEETS E-001 AND E-002 FOR ADDITIONAL INFORMATION.BALL PRODUTS TO BE HANDLED, STORED, AND INSTALLED PER MANUFACTURERREQUIREMENTS.CCOMPLY WITH ALL APPLICABLE CODES AND REGULATIONS PERTAINING TO THISSCOPE OF WORK.OVERALL BUILDING PLAN NOTES#NOTES1/16" = 1'-0"2AOVERALL FIRST FLOOR PLAN#RevisionDate HVHMHDVTVHMSJHVHJCRCR678549A21BCDE101112HJKLFGA5E.P678549A21BCDE101112HJKLFGA5E.PG1G2PL1FAAPFACP-111121255555N123456ABCDE123456ABCDEProject No.Project DateProducedThese Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect.KEY PLANBA5/22/2023 10:18:02 AMC:\_RevitLocal\2023-067.POR_Bldg001_E_2023\2023-067.POR_Bldg001_E_2023_smathis.rvt2023-067.POR05.22.2023FIRST FLOORDEMOLITION PLAN -UNITAED1A1SACM JNSCoram DeoAcademyPhase OneRenovations2023-067.POR_Coram Deo Academy_Phase One Renovations_525 Congressional Blvd,Carmel, IN 46032ED1A1_ FIRST FLOOR DEMOLITION PLAN -UNIT ADEMOLITION PLAN NOTES#NOTES1DISCONNECT AND REMOVE EXISTING LIGHTING FIXTURE(S). CLEAN AND RELAMPLIGTHS FOR REINSTALLION INTO NEW GRID. LIGHTINGS CIRCUIT TO REMAIN FORRECONNECTING TO LIGHTS.2RELOCATE EXISTING EXIT SIGN.3EXISTING LIGHT SWITCH TO BE RELOCATED.4DISCONNECT AND REMOVE POWER POLES SERVING FURNITURE SYSTEMS.5RELOCATE EXISTING EMERGENCY WALLPACK LIGHT(S).5RELOCATE EXISTING LIGHTS.6RELOCATE EXISTING PANEL SERVING FIRE ALARM PANEL TO IDF ROOMCOMPLETE. COORDINATE LOCATION WITH OWNER.7RELOCATE EXISTING GFCI/COUNTERTOP RECEPTACLE.8RELOCATE EXISTING GFCI/COUNTERTOP RECEPTACLE DOWN WALL AS REQUIREDFOR NEW WALL OPENING.GENERAL DEMOLITION NOTES#NOTESAREFER TO SHEETS E-001 AND E-002 FOR ADDITIONAL INFORMATION.BTHIS DRAWING REPRESENTS INFORMATION OBTAINED FROM ORIGINALCONTRACT DRAWINGS AND FIELD SURVEY. VERIFY BY ON-SITE OBSERVATIONTHE EXTENT OF WORK PRIOR TO SUBMISSION OF BID.CCONTRACT DOCUMENTS CONSIST OF BOTH PROJECT MANUAL AND DRAWINGSAND ARE MEANT TO BE COMPLEMENTARY. ANYTHING APPEARING ON EITHERMUST BE EXECUTED THE SAME AS IF SHOWN ON BOTH.DTHOROUGHLY EXAMINE THE WORK OF OTHER CONTRACTORS AND PROPERLYINSTALL ALL WORK REQUIRED FOR THE PROJECT.ETHE OWNER HOLDS RIGHT OF FIRST REFUSAL FOR ALL DEMOLISHED ELECTRICALEQUIPMENT.FALL ELECTRICAL ITEMS SHOWN WITH LIGHT LINEWORK ARE EXISTING TO REMAIN.GREMOVE ALL ELECTRICAL ITEMS SHOWN WITH BOLD/DASHED LINEWORKCOMPLETE.HCOORDINATE AND DISCONNECT ALL CIVIL, ARCHITECTURAL, MECHANICAL,PLUMBING, AND TELECOMMUNICATION EQUIPMENT AS NOTED FOR REMOVAL BYOTHERS. REMOVE ALL ASSOCIATED ELECTRICAL EQUIPMENT, RACEWAYS,CONDUCTORS, ETC. SERVING THE EQUIPMENT.IPROVIDE ALL CUTTING AND PATCHING AS REQUIRED FOR THE REMOVAL OFEXISTING ELECTRICAL EQUIPMENT. REFER TO SPECIFICATIONS.JPROVIDE A BLANK COVERPLATE FOR ALL EXISTING WALL OPENINGS WHEREELECTRICAL EQUIPMENT HAS BEEN REMOVED AND NOT REPLACED. IN AREASRECEIVING NEW WALL TREATMENTS, PATCH THE EXISTING OPENING.KREFER TO A, M, P, AND T-SERIES DRAWINGS FOR AREAS WITH ABOVE CEILINGWORK AND/OR CEILING REMOVAL. TEMPORARILY SUPPORT ALL ELECTRICALDEVICES, FIXTURES, ETC. AS REQUIRED. RE-INSTALL ELECTRICAL ITEMSFOLLOWING THE COMPLETION OF WORK IN THE NEW OR EXISTING CEILINGS.LREMOVE SYSTEMS AND EQUIPMENT MADE OBSOLETE BY THIS PROJECT. THISINCLUDES, BUT IS NOT LIMITED TO, CONDUIT, RACEWAYS, WIREWAYS,CONDUCTORS, JUNCTION BOXES, WIRING DEVICES, LIGHT FIXTURES, PULLBOXES, DISCONNECTS, MOTOR STARTERS, CONTACTORS, ETC.MREMOVE ALL DEBRIS FROM SITE AND LEGALLY DISPOSE OF SAME.NREMOVE ALL EXISTING EQUIPMENT PADS MADE OBSOLETE. CUT OFF BELOWFLOOR SLAB AND FILL WITH CONCRETE ALL CONDUITS WHICH ARE ABANDONEDIN OR BELOW THE FLOOR SLAB. PATCH FLOOR TO MATCH EXISTING CONDITIONS.OALL PRODUTS TO BE HANDLED, STORED, AND INSTALLED PER MANUFACTURERREQUIREMENTS.PCOMPLY WITH ALL APPLICABLE CODES AND REGULATIONS PERTAINING TO THISSCOPE OF WORK.1/8" = 1'-0"1AFIRST FLOOR DEMOLITION PLAN -UNIT A#RevisionDate DVVVSFHMSFHDDGFCIGFCIVVVHHJVPRPTPR5A21BCDGA5A4A3A2A1E.P5A21BCDGA5A4A3A2A1E.PFAPPNL-1MS135544362355555258555555555ABA1ABA1N123456ABCDE123456ABCDEProject No.Project DateProducedThese Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect.KEY PLANBA5/22/2023 10:18:17 AMC:\_RevitLocal\2023-067.POR_Bldg001_E_2023\2023-067.POR_Bldg001_E_2023_smathis.rvt2023-067.POR05.22.2023FIRST FLOORDEMOLITION PLAN -UNITBED1B1SACM JNSCoram DeoAcademyPhase OneRenovations2023-067.POR_Coram Deo Academy_Phase One Renovations_525 Congressional Blvd,Carmel, IN 46032ED1B1_ FIRST FLOOR DEMOLITION PLAN -UNIT BDEMOLITION PLAN NOTES#NOTES1DISCONNECT AND REMOVE EXISTING LIGHTING FIXTURE(S). CLEAN AND RELAMPLIGTHS FOR REINSTALLION INTO NEW GRID. LIGHTINGS CIRCUIT TO REMAIN FORRECONNECTING TO LIGHTS.2RELOCATE EXISTING EXIT SIGN.3EXISTING LIGHT SWITCH TO BE RELOCATED.4DISCONNECT AND REMOVE POWER POLES SERVING FURNITURE SYSTEMS.5RELOCATE EXISTING EMERGENCY WALLPACK LIGHT(S).5RELOCATE EXISTING LIGHTS.6RELOCATE EXISTING PANEL SERVING FIRE ALARM PANEL TO IDF ROOMCOMPLETE. COORDINATE LOCATION WITH OWNER.7RELOCATE EXISTING GFCI/COUNTERTOP RECEPTACLE.8RELOCATE EXISTING GFCI/COUNTERTOP RECEPTACLE DOWN WALL AS REQUIREDFOR NEW WALL OPENING.GENERAL DEMOLITION NOTES#NOTESAREFER TO SHEETS E-001 AND E-002 FOR ADDITIONAL INFORMATION.BTHIS DRAWING REPRESENTS INFORMATION OBTAINED FROM ORIGINALCONTRACT DRAWINGS AND FIELD SURVEY. VERIFY BY ON-SITE OBSERVATIONTHE EXTENT OF WORK PRIOR TO SUBMISSION OF BID.CCONTRACT DOCUMENTS CONSIST OF BOTH PROJECT MANUAL AND DRAWINGSAND ARE MEANT TO BE COMPLEMENTARY. ANYTHING APPEARING ON EITHERMUST BE EXECUTED THE SAME AS IF SHOWN ON BOTH.DTHOROUGHLY EXAMINE THE WORK OF OTHER CONTRACTORS AND PROPERLYINSTALL ALL WORK REQUIRED FOR THE PROJECT.ETHE OWNER HOLDS RIGHT OF FIRST REFUSAL FOR ALL DEMOLISHED ELECTRICALEQUIPMENT.FALL ELECTRICAL ITEMS SHOWN WITH LIGHT LINEWORK ARE EXISTING TO REMAIN.GREMOVE ALL ELECTRICAL ITEMS SHOWN WITH BOLD/DASHED LINEWORKCOMPLETE.HCOORDINATE AND DISCONNECT ALL CIVIL, ARCHITECTURAL, MECHANICAL,PLUMBING, AND TELECOMMUNICATION EQUIPMENT AS NOTED FOR REMOVAL BYOTHERS. REMOVE ALL ASSOCIATED ELECTRICAL EQUIPMENT, RACEWAYS,CONDUCTORS, ETC. SERVING THE EQUIPMENT.IPROVIDE ALL CUTTING AND PATCHING AS REQUIRED FOR THE REMOVAL OFEXISTING ELECTRICAL EQUIPMENT. REFER TO SPECIFICATIONS.JPROVIDE A BLANK COVERPLATE FOR ALL EXISTING WALL OPENINGS WHEREELECTRICAL EQUIPMENT HAS BEEN REMOVED AND NOT REPLACED. IN AREASRECEIVING NEW WALL TREATMENTS, PATCH THE EXISTING OPENING.KREFER TO A, M, P, AND T-SERIES DRAWINGS FOR AREAS WITH ABOVE CEILINGWORK AND/OR CEILING REMOVAL. TEMPORARILY SUPPORT ALL ELECTRICALDEVICES, FIXTURES, ETC. AS REQUIRED. RE-INSTALL ELECTRICAL ITEMSFOLLOWING THE COMPLETION OF WORK IN THE NEW OR EXISTING CEILINGS.LREMOVE SYSTEMS AND EQUIPMENT MADE OBSOLETE BY THIS PROJECT. THISINCLUDES, BUT IS NOT LIMITED TO, CONDUIT, RACEWAYS, WIREWAYS,CONDUCTORS, JUNCTION BOXES, WIRING DEVICES, LIGHT FIXTURES, PULLBOXES, DISCONNECTS, MOTOR STARTERS, CONTACTORS, ETC.MREMOVE ALL DEBRIS FROM SITE AND LEGALLY DISPOSE OF SAME.NREMOVE ALL EXISTING EQUIPMENT PADS MADE OBSOLETE. CUT OFF BELOWFLOOR SLAB AND FILL WITH CONCRETE ALL CONDUITS WHICH ARE ABANDONEDIN OR BELOW THE FLOOR SLAB. PATCH FLOOR TO MATCH EXISTING CONDITIONS.OALL PRODUTS TO BE HANDLED, STORED, AND INSTALLED PER MANUFACTURERREQUIREMENTS.PCOMPLY WITH ALL APPLICABLE CODES AND REGULATIONS PERTAINING TO THISSCOPE OF WORK.1/8" = 1'-0"2BFIRST FLOOR DEMOLITION PLAN -UNIT B1/8" = 1'-0"5DALTERNATE -DEMOLITION#RevisionDate 678549A21BCDE101112HJKLFGA5E.P678549A21BCDE101112HJKLFGA5E.PG1G2PL1123245663333333377772216PARENT ROOMB100COPIERB109STORAGEB112CLASSROOMB121CLASSROOMB120CLASSROOMB110CAFETERIAB111APARENT ROOMB100STORAGEB112533N123456ABCDE123456ABCDEProject No.Project DateProducedThese Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect.KEY PLANBA5/22/2023 10:18:33 AMC:\_RevitLocal\2023-067.POR_Bldg001_E_2023\2023-067.POR_Bldg001_E_2023_smathis.rvt2023-067.POR05.22.2023FIRST FLOOR LIGHTINGPLAN -UNIT AEL1A1SACM JNSCoram DeoAcademyPhase OneRenovations2023-067.POR_Coram Deo Academy_Phase One Renovations_525 Congressional Blvd,Carmel, IN 46032EL1A1_ FIRST FLOOR LIGHTING PLAN -UNIT ALIGHTING PLAN NOTES#NOTES1EXISTING LIGHTS TO REMAIN. MODIFY CIRCUIT AS REQUIRED FOR NEW LIGHTINGCONTROLS.2RECESS TOGGLE SWITCH IN EXISTING WALL.3PROVIDE NEW LIGHT SWITCH IN EXISTING LOCATION.4REINSTALL EXISTING LIGHTS FROM DEMOLITION. MODIFY EXISTING LIGHTINGCIRCUIT AS REQUIRED FOR NEW LIGHTING CONTROL.5RELOCATE EXISTING EXIT SIGN.6REINSTALL EXISTING LIGHTING(S) FROM DEMOLITION. CONNECT TO EXISTINGLIGHTING CIRCUIT AND NEW CONTROLS IN ROOM AS INDICATED.7RECONNECT EXISTING EMERGENCY WALLPACK TO CIRCUIT FROM DEMOLITION.8RELOCATE EXISTING LIGHT SWITCH FROM DEMOLITION.9RELOCATE EXISTING EMERGENCY WALLPACK LIGHT(S).10REINSTALL EXISTING LIGHTS FROM DEMOLITION. MODIFY EXISTING LIGHTINGCIRCUIT AS REQUIRED FOR TO TIE INTO ADJACENT ROOMS LIGHTING CONTROL.11REINSTALL EXISTING LIGHTING(S) FROM DEMOLITION. CONNECT TO EXISTINGLIGHTING CIRCUIT AND CONTROLS IN CORRIDOR.12PROVIDE NEW LIGHT SWITCH.13PROVIDE NEW EXIT SIGN AND TIE INTO NEAREST CIRCUIT SERVING EXIT SIGNS.14PROVIDE NEW LIGHTS AND CONNECT TO NEW SWITCHING AS SHOWN. CONNECTTO EXISTING LIGHTING CIRCUIT FROM DEMOLITION.15PROVIDE NEW LIGHT AND CONNECT TO EXISTING CIRCUIT/SWITCHING INCORRIDOR.16RELOCATE EXISTING LIGHTS.GENERAL LIGHTING NOTES#NOTESAREFER TO SHEETS E-001 AND E-002 FOR ADDITIONAL INFORMATION.BPROVIDE CHAIN SUPPORTS TO STRUCTURE FOR EXISTING LIGHT FIXTURES TOREMAIN IN CEILINGS BEING REMOVED AND REINSTALLED.CALL PRODUTS TO BE HANDLED, STORED, AND INSTALLED PER MANUFACTURERREQUIREMENTS.DCOMPLY WITH ALL APPLICABLE CODES AND REGULATIONS PERTAINING TO THISSCOPE OF WORK.1/8" = 1'-0"1AFIRST FLOOR LIGHTING PLAN -UNIT A#RevisionDate DDO1O1O1O15A21BCDGA5A4A3A2A1E.P5A21BCDGA5A4A3A2A1E.PPNL-13333339933221623177771061111KITCHENB128COPIERB109PRE-KB132OFFICEB131CLASSROOMB130CLASSROOMB126CLASSROOMB121CLASSROOMB120CLASSROOMB110CAFETERIAB111AKITCHENETTEB122PLUMBINGB123OFFICEB124CLASSROOMB119MENS RRB149OFFICEB147OFFICEB119ACLASSROOMB118STORAGEB146ACLASSROOMB145STORAGEB144STORAGEB143STORAGEB142COMMONSB141STORAGEB140STORAGEB139CORRIDORB001CLASSROOMB138CLASSROOMB127WOMENS RRB148STORAGEB129ALIBRARYB135CLASSROOMB136IDFB129CAFETERIAB111ASTORAGEB146STORAGEB129BL1L1L1L1L1L1L1L1L1L1L1L1L1L15988128599999513X1C1X1C1L113L2L2L2L2L2L2L2L214151451116ABA1ABA132132N123456ABCDE123456ABCDEProject No.Project DateProducedThese Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect.KEY PLANBA5/22/2023 10:18:47 AMC:\_RevitLocal\2023-067.POR_Bldg001_E_2023\2023-067.POR_Bldg001_E_2023_smathis.rvt2023-067.POR05.22.2023FIRST FLOOR LIGHTINGPLAN -UNIT BEL1B1SACM JNSCoram DeoAcademyPhase OneRenovations2023-067.POR_Coram Deo Academy_Phase One Renovations_525 Congressional Blvd,Carmel, IN 46032EL1B1_ FIRST FLOOR LIGHTING PLAN -UNIT BLIGHTING PLAN NOTES#NOTES1EXISTING LIGHTS TO REMAIN. MODIFY CIRCUIT AS REQUIRED FOR NEW LIGHTINGCONTROLS.2RECESS TOGGLE SWITCH IN EXISTING WALL.3PROVIDE NEW LIGHT SWITCH IN EXISTING LOCATION.4REINSTALL EXISTING LIGHTS FROM DEMOLITION. MODIFY EXISTING LIGHTINGCIRCUIT AS REQUIRED FOR NEW LIGHTING CONTROL.5RELOCATE EXISTING EXIT SIGN.6REINSTALL EXISTING LIGHTING(S) FROM DEMOLITION. CONNECT TO EXISTINGLIGHTING CIRCUIT AND NEW CONTROLS IN ROOM AS INDICATED.7RECONNECT EXISTING EMERGENCY WALLPACK TO CIRCUIT FROM DEMOLITION.8RELOCATE EXISTING LIGHT SWITCH FROM DEMOLITION.9RELOCATE EXISTING EMERGENCY WALLPACK LIGHT(S).10REINSTALL EXISTING LIGHTS FROM DEMOLITION. MODIFY EXISTING LIGHTINGCIRCUIT AS REQUIRED FOR TO TIE INTO ADJACENT ROOMS LIGHTING CONTROL.11REINSTALL EXISTING LIGHTING(S) FROM DEMOLITION. CONNECT TO EXISTINGLIGHTING CIRCUIT AND CONTROLS IN CORRIDOR.12PROVIDE NEW LIGHT SWITCH.13PROVIDE NEW EXIT SIGN AND TIE INTO NEAREST CIRCUIT SERVING EXIT SIGNS.14PROVIDE NEW LIGHTS AND CONNECT TO NEW SWITCHING AS SHOWN. CONNECTTO EXISTING LIGHTING CIRCUIT FROM DEMOLITION.15PROVIDE NEW LIGHT AND CONNECT TO EXISTING CIRCUIT/SWITCHING INCORRIDOR.16RELOCATE EXISTING LIGHTS.GENERAL LIGHTING NOTES#NOTESAREFER TO SHEETS E-001 AND E-002 FOR ADDITIONAL INFORMATION.BPROVIDE CHAIN SUPPORTS TO STRUCTURE FOR EXISTING LIGHT FIXTURES TOREMAIN IN CEILINGS BEING REMOVED AND REINSTALLED.CALL PRODUTS TO BE HANDLED, STORED, AND INSTALLED PER MANUFACTURERREQUIREMENTS.DCOMPLY WITH ALL APPLICABLE CODES AND REGULATIONS PERTAINING TO THISSCOPE OF WORK.1/8" = 1'-0"2AFIRST FLOOR LIGHTING PLAN -UNIT B1/8" = 1'-0"5DALTERNATE -LIGHTING#RevisionDate TTVHMHVTVSJHVHCRGFCIGFCIGFCIVMVARSDSDSDJARARARJJJJJ678549A21BCDE101112HJKLFGA5E.P678549A21BCDE101112HJKLFGA5E.PG1G2PL111111PARENT ROOMB100COPIERB109STORAGEB112CLASSROOMB120CLASSROOMB110CAFETERIAB111APARENT ROOMB100STORAGEB112LOBBYA100CLINICA101OFFICEA102OFFICEA104STORAGEA106ASCIENCE LABA121OFFICEA119CLASSROOMA120CLASSROOMA118BREAK ROOMA106OFFICEA105OFFICEA103CORRIDORA001UNOCCUPIEDA122UNOCCUPIEDA123UNOCCUPIEDA124UNOCCUPIEDA125UNOCCUPIEDA126UNOCCUPIEDA127UNOCCUPIEDA128UNOCCUPIEDA129UNOCCUPIEDA130CLASSROOMA113CLASSROOMA116OFFICEA114OFFICEA115CORRIDORA003STORAGEA112STORAGEA111STORAGEA117GYMA110ELECTRICALA112ACLASSROOMB117PRACTICE ROOMB117ACLASSROOMB115PRACTICE ROOMB116PRACTICE ROOMB114PRACTICE ROOMB113OFFICEB115ASTORAGEB115BSTORAGEB115COFFICEB107OFFICEB108OFFICEB106OFFICEB105VESTIBULEA003BVESTIBULEA100ACORRIDORA002VESTIBULEA110BRRA110CEP1A12ERPB-2MGP-122CIRCUIT 1CIRCUIT 2CIRCUIT 1CIRCUIT 2CIRCUIT 1MS-A145F203F20299GFCIGFCI98101011KLG1011KLGEF-A16GFCI/WPN123456ABCDE123456ABCDEProject No.Project DateProducedThese Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect.KEY PLANBA5/22/2023 1:02:50 PMC:\_RevitLocal\2023-067.POR_Bldg001_E_2023\2023-067.POR_Bldg001_E_2023_jboosey.rvt2023-067.POR05.22.2023FIRST FLOOR POWERPLAN -UNIT AEP1A1SACM JNSCoram DeoAcademyPhase OneRenovations2023-067.POR_Coram Deo Academy_Phase One Renovations_525 Congressional Blvd,Carmel, IN 46032EP1A1_ FIRST FLOOR POWER PLAN -UNIT APOWER PLAN NOTES#NOTES1CONNECT TO NEAREST SPARE 120V-1P, 20A CIRCUIT. TEXT NEXT TO PLAN NOTEINDICATED CIRCUIT GROUPING.2RECEPTACLE FOR PROJECTOR LOCATED FLUSH WITH CEILING TILE/INPROJECTOR PAN. COORDINATE LOCATION OF RECEPTACLE WITH OWNER PRIORTO INSTALLATION. CONNECT TO NEAREST 120V, 20A-1P SPARE CIRCUITBREAKER.3CIRCUIT CONNECTION FOR EMERGENCY GAS SHUTOFF VALVE. PROVIDE ALLCONDUIT AND WIRING BETWEEN CONTROL PANEL AND SOLENOIDVALVES/EMERGENCY SHUTOFF BUTTONS AS INDICATED ON P-SERIES DRAWINGS.PROVIDE FIRE ALARM ADDRESSABLE RELAY IN SERIES WITH SHUTOFF BUTTONWIRNG SUCH THAT GAS VALVES WILL CLOSE ON AN ALARM IN FIRE ALARMSYSTEM. CONNECT TO NEAREST SPARE DEDICATED 20A-1P, 120V CIRCUITBREAKER.4CONNECT TO NEAREST DEDICATED SPARE 120V-1P, 20A CIRCUIT.5PROVIDE MOTOR STARTER IN FUME HOOD. COORDINATE INSTALLATION WITHMANUFACTURER. CONNECT TO EXHAUST FAN ON ROOM. DISCONNECT INEXHAUST FAN BY EXHAUST FAN MANUFACTURER.6TIE MOTOR STARTER FOR FUME HOOD TO MANUFACTURER PROVIDEDDISCONNECT IN EXHAUST FAN. PROVIDE NEW GRCI/WEATHER PROOF DUPLEXRECEPACLE AT EXHAUST FAN. TIE INTO NEAREST DEDICATED 20A-1P, 120VCIRCUIT BREAKER.7CONNECT MECHANICAL EQUIPMENT TO NEAREST SPARE DEDICATED 20A-1P,277V CIRCUIT BREAKER. CONNECT TO MANUFACTURER PROVIDED DISCONNECTIN UNIT.8PROVIDE DEDICATED SINGLE 120V, 1P-20A CIRCUIT TO ALL SMOKE ORFIRE/SMOKE DAMPER MOTORS INDICATED. CONNECT CIRCUIT THROUGH FIREALARM ADDRESSABLE RELAY. DAMPER WILL CLOSE WHEN DUCT DETECTORSDETECT SMOKE. PROVIDE WIRING TO CONNECT TO REMOTE DAMPER TESTSWITCH BY DIVISION 23 CONTRACTOR. REFER TO SCHEMATICS AND M-SERIESSHEETS FOR MORE INFORMATION AND TEST SWITCH LOCATION.9PROVIDE DUCT DETECTOR FOR FIRE/SMOKE DAMPERS.10PROVIDE OWNER PROVIDED CARD READER ROUGH IN 46" A.F.F.GENERAL POWER NOTES#NOTESAREFER TO SHEETS E-001 AND E-002 FOR ADDITIONAL INFORMATION.BALL PRODUTS TO BE HANDLED, STORED, AND INSTALLED PER MANUFACTURERREQUIREMENTS.CCOMPLY WITH ALL APPLICABLE CODES AND REGULATIONS PERTAINING TO THISSCOPE OF WORK.DFOR BIDDING PURPOSES, ASSUME A PANELBOARD WITH SPARE BREAKERS ISWITHIN 100' OF EDGE OF ROOM TO ROOM WITH PANELBOARD.1/8" = 1'-0"1AFIRST FLOOR POWER PLAN -UNIT A1/8" = 1'-0"2EROOF PLAN -A121#RevisionDate TTTTTVVVSFHMSFHGFCIGFCIVVVHHVVVHMVPTVV5A21BCDGA5A4A3A2A1E.P5A21BCDGA5A4A3A2A1E.PPNL-1KITCHENB128COPIERB109PRE-KB132OFFICEB131CLASSROOMB130CLASSROOMB126CLASSROOMB121CLASSROOMB120CLASSROOMB110CAFETERIAB111AKITCHENETTEB122PLUMBINGB123OFFICEB124CLASSROOMB119MENS RRB149OFFICEB147OFFICEB119ACLASSROOMB118STORAGEB146ACLASSROOMB145STORAGEB144STORAGEB143STORAGEB142COMMONSB141STORAGEB140STORAGEB139CORRIDORB001UnoccupiedUnoccupiedCLASSROOMB138CLASSROOMB127WOMENS RRB148STORAGEB129ALIBRARYB135CLASSROOMB136IDFB129CAFETERIAB111ASTORAGEB146STORAGEB129BCLASSROOMB121KITCHENETTEB122CORRIDORB001CLASSROOMB121KITCHENETTEB122CORRIDORB00122222111CIRCUIT 3CIRCUIT 3CIRCUIT 3CIRCUIT 4CIRCUIT 411ECUH-2ECUH-17F207F20ABA1ABA12N123456ABCDE123456ABCDEProject No.Project DateProducedThese Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect.KEY PLANBA5/22/2023 1:03:01 PMC:\_RevitLocal\2023-067.POR_Bldg001_E_2023\2023-067.POR_Bldg001_E_2023_jboosey.rvt2023-067.POR05.22.2023FIRST FLOOR POWERPLAN -UNIT BEP1B1SACM JNSCoram DeoAcademyPhase OneRenovations2023-067.POR_Coram Deo Academy_Phase One Renovations_525 Congressional Blvd,Carmel, IN 46032EP1B1_ FIRST FLOOR POWER PLAN -UNIT BPOWER PLAN NOTES#NOTES1CONNECT TO NEAREST SPARE 120V-1P, 20A CIRCUIT. TEXT NEXT TO PLAN NOTEINDICATED CIRCUIT GROUPING.2RECEPTACLE FOR PROJECTOR LOCATED FLUSH WITH CEILING TILE/INPROJECTOR PAN. COORDINATE LOCATION OF RECEPTACLE WITH OWNER PRIORTO INSTALLATION. CONNECT TO NEAREST 120V, 20A-1P SPARE CIRCUITBREAKER.3CIRCUIT CONNECTION FOR EMERGENCY GAS SHUTOFF VALVE. PROVIDE ALLCONDUIT AND WIRING BETWEEN CONTROL PANEL AND SOLENOIDVALVES/EMERGENCY SHUTOFF BUTTONS AS INDICATED ON P-SERIES DRAWINGS.PROVIDE FIRE ALARM ADDRESSABLE RELAY IN SERIES WITH SHUTOFF BUTTONWIRNG SUCH THAT GAS VALVES WILL CLOSE ON AN ALARM IN FIRE ALARMSYSTEM. CONNECT TO NEAREST SPARE DEDICATED 20A-1P, 120V CIRCUITBREAKER.4CONNECT TO NEAREST DEDICATED SPARE 120V-1P, 20A CIRCUIT.5PROVIDE MOTOR STARTER IN FUME HOOD. COORDINATE INSTALLATION WITHMANUFACTURER. CONNECT TO EXHAUST FAN ON ROOM. DISCONNECT INEXHAUST FAN BY EXHAUST FAN MANUFACTURER.6TIE MOTOR STARTER FOR FUME HOOD TO MANUFACTURER PROVIDEDDISCONNECT IN EXHAUST FAN. PROVIDE NEW GRCI/WEATHER PROOF DUPLEXRECEPACLE AT EXHAUST FAN. TIE INTO NEAREST DEDICATED 20A-1P, 120VCIRCUIT BREAKER.7CONNECT MECHANICAL EQUIPMENT TO NEAREST SPARE DEDICATED 20A-1P,277V CIRCUIT BREAKER. CONNECT TO MANUFACTURER PROVIDED DISCONNECTIN UNIT.8PROVIDE DEDICATED SINGLE 120V, 1P-20A CIRCUIT TO ALL SMOKE ORFIRE/SMOKE DAMPER MOTORS INDICATED. CONNECT CIRCUIT THROUGH FIREALARM ADDRESSABLE RELAY. DAMPER WILL CLOSE WHEN DUCT DETECTORSDETECT SMOKE. PROVIDE WIRING TO CONNECT TO REMOTE DAMPER TESTSWITCH BY DIVISION 23 CONTRACTOR. REFER TO SCHEMATICS AND M-SERIESSHEETS FOR MORE INFORMATION AND TEST SWITCH LOCATION.9PROVIDE DUCT DETECTOR FOR FIRE/SMOKE DAMPERS.10PROVIDE OWNER PROVIDED CARD READER ROUGH IN 46" A.F.F.GENERAL POWER NOTES#NOTESAREFER TO SHEETS E-001 AND E-002 FOR ADDITIONAL INFORMATION.BALL PRODUTS TO BE HANDLED, STORED, AND INSTALLED PER MANUFACTURERREQUIREMENTS.CCOMPLY WITH ALL APPLICABLE CODES AND REGULATIONS PERTAINING TO THISSCOPE OF WORK.DFOR BIDDING PURPOSES, ASSUME A PANELBOARD WITH SPARE BREAKERS ISWITHIN 100' OF EDGE OF ROOM TO ROOM WITH PANELBOARD.1/8" = 1'-0"2AFIRST FLOOR POWER PLAN -UNIT B1/8" = 1'-0"5DALTERNATE -POWER#RevisionDate 4" SQ. COMBO BOXSINGLE GANG PLASTER RING WITH GROUND SCREW AND PIGTAIL TO MATCH DRYWALL THICKNESS9/32" DIA. STEEL RODSUSPENSION FROMBLDG. STRUCTUREWITHIN 3' OF OUTLETBOX8' MAX. SPACINGBETWEEN HANGERSSTEEL OUTLET BOX -SIZED PER N.E.C. ANDSUPPORTED RIGIDLYFROM STRUCTURECONDUIT6' MAX. LENGTH -3/8" FLEXCONDUIT W/ 3-#12 CONDUCTORSFACTORY WIRE INTO FIXTURETYPICAL LAY-INRECESSEDLIGHT FIXTURESECURE FIXTURES TO GRID WITH CLIPS PERN.E.C.T-BAR LAY-IN CEILINGSUSPENSION SYSTEMUTILIZE CHAIN FOR SUPPORT3' MAX. FROM BOX TO HANGERCONDUIT CLAMPNOTE:DO NOT SUPPORTCONDUIT OR BOXFROM CEILINGGRID HANGERSGNPGNPGPNCONDUITWIRE NUTGROUND SCREW#10X32X3/8" SLOTTED HEX HEAD WASHER FACETAPPED HOLE IN BOXT AND B EYE TERMINAL (INSULATED)OUTLET BOXDEVICE YOKEGROUND CONNECTIONS SHALL BE CONTINUOUS SO THAT REMOVAL OF DEVICE WILL NOT INTERFERE WITH CONDUCTOR CONTINUITY6.35mm (1/4") SCREWGENERAL NOTE:1. INSTALL IN ACCORDANCE WITH MANUFACTURER'S MOUNTING INSTRUCTIONS AND USING THE RECOMMENDED MOUNTING HARDWARE.ARCHITECTURALCEILING GRIDLOCKING SQUAREWASHER & NUTJUNCTION BOXACOUSTICALCEILING TILE (TYP)ARCHITECTURALCEILING GRIDWIRE TIE THROUGHMOUNTING CHANNEL& CROSS BEAM (TYP)ARCHITECTURALCEILING GRIDCEILING HANGER WIREFIXTURE WHIP FROM JUNCTION BOX(1829mm (6') LONG MAX)HANGER WIRE AND MOUNTINGCHANNEL ATTACHED TO STRUCTUREREFER TO SPECIFICATION SECTION26 51 00INTEGRAL GALVANIZED LIPPEDSTEEL MOUNTING CHANNELCADDY COMBINATION CONDUIT HANGER CLAMP OR EQUALSUPPORT STRUCTURECADDY STRUT CLIP OR EQUALROD SIZE AS REQUIREDCADDY ROD HANGER CLAMP OR EQUALCADDY CONDUIT CLAMP OR EQUAL. SIZE AS REQUIREDUNISTRUT CHANNEL OR EQUAL1ST FLOOREXISTING REMOTEANNUNCIATORPANELNOTES:1.REFER TO FLOOR PLANS FOR DEVICE QUANTITIES2.ALL VISUAL DEVICES AND HORN/STROBES TOBE SYNCHRONIZED FLASHEXISTING FIREALARMCONTROLPANELFRFSMEXISTING FIRE ALARMNACPANEL120V CIRCUITVHNOTES:SUPPORTING CABLE IS ACCEPTIBLE BELOW SUPPORT STEEL OR ABOVE STEEL.COORDINATE MOUNTING LOCATIONS WITH OTHER TRADES AND FIELD CONDITIONS.PROVIDE SUPPORT CLIPS AND THREADED RODES AS REQUIRED FOR A COMPLETESUPPORT SYSTEM AS INDICATED.SUPPORT CABLES FROM EITHER PARALLEL OR PERPENDICULAR SUPPORT STEEL.BUNDLE A UP TO A MAXIMUM OF (6) SIX CABLES.1.2.3.TYPICAL BEAM ORSTRUCTURAL SUPPORTTYPICAL BEAM CLAMPBOLTED, THREADED TYPE1/4" THREADED RODPROVIDE CHECKNUTTYPICAL MC OR AC CABLESUPPORT MAX. 5'-0" O.C.FLEXIBLE CABLE SUPPORT CLIPS,CADDY FASTENER NO. PCS1 ORAPPROVED EQUAL (TYPICAL).N123456ABCDE123456ABCDEProject No.Project DateProducedThese Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect.KEY PLANBA5/22/2023 10:17:36 AMC:\_RevitLocal\2023-067.POR_Bldg001_E_2023\2023-067.POR_Bldg001_E_2023_smathis.rvt2023-067.POR05.22.2023GENERAL DETAILSE-501SACM JNSCoram DeoAcademyPhase OneRenovations2023-067.POR_Coram Deo Academy_Phase One Renovations_525 Congressional Blvd,Carmel, IN 46032E-501_ GENERAL DETAILSNOT TO SCALE1ARECEPTACLE SUPPORT DETAILNOT TO SCALE2ARECESSED LIGHTING INSTALLATION#RevisionDateNOT TO SCALE1BDEVICE GROUNDING DETAILNOT TO SCALE4AEXIT SIGN MOUNTING -LAY-IN CEILINGDETAILNOT TO SCALE2BCONDUIT 2" AND SMALLER SUPPORTDETAILNOT TO SCALE4BCONDUIT 2-1/2" AND LARGER SUPPORTDETAILNOT TO SCALE1DFIRE ALARM SCHEMATICNOT TO SCALE5DMETAL CLAD (MC) CABLE STRUCTURALSUPPORT DETAIL N123456ABCDE123456ABCDEProject No.Project DateProducedThese Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect.KEY PLANBA5/22/2023 10:17:48 AMC:\_RevitLocal\2023-067.POR_Bldg001_E_2023\2023-067.POR_Bldg001_E_2023_smathis.rvt2023-067.POR05.22.2023LIGHTING ANDEQUIPMENT SCHEDULESE-601SACM JNSCoram DeoAcademyPhase OneRenovations2023-067.POR_Coram Deo Academy_Phase One Renovations_525 Congressional Blvd,Carmel, IN 46032E-601_ LIGHTING AND EQUIPMENT SCHEDULESGENERAL LIGHT FIXTURE SCHEDULENOTES#NOTESAPROVIDE ALL FIXTURES AND FIXTURE INSTALLATIONS IN ACCORDANCE WITHNEC, NFPA, AND LOCAL CODES. PROVIDE UL LISTED FIXTURES AND INSTALL INACCORDANCE WITH THE LISTING.BCOORDINATE ALL FIXTURE DEVICES, COMPONENTS, FITTINGS, SUPPORTS, ETC.REQUIRED FOR A COMPLETE UL LISTED INSTALLATION.CPROVIDE ALL DRIVERS, LED MODULES, LENSES, ETC. AS REQUIRED FOR ACOMPLETE AND OPERATIONAL LIGHTING UNIT.DBID ONLY THE LIGHTING MANUFACTURERS/SERIES SPECIFIED IN THE LIGHTFIXTURE SCHEDULE. A DOCUMENTED PRE-BID SUBMITTAL MUST BE APPROVEDBY THE ENGINEER OF THE PROJECT FOR ANY ADDITION/SUBSTITUTION OF THEMANUFACTURERS LISTED DURING BIDDING. APPROVED MANUFACTURERS WILLBE ADDED/MODIFIED ONLY BY ADDENDUM.ECOORDINATE LIGHTING SYSTEM REQUIREMENTS, INCLUDING BUT NOT LIMITEDTO, THE LIGHT FIXTURE SCHEDULE, PLANS, PLAN NOTES, DETAILS, SCHEMATICS,SPECIFICATIONS, ETC.FREFER TO LIGHT FIXTURE SCHEDULE, LIGHTING PLANS, AND ARCHITECTURALREFLECTED CEILING PLANS FOR ALL CEILING TYPES, FINAL LOCATIONS,ELEVATIONS, AND FIXTURE LENGTHS REQUIRED.GLUMEN VALUES LISTED IN THE LIGHT FIXTURE SCHEDULES ARE THE MINIMUMDELIVERED LUMENS ALLOWED. PROVIDE LIGHT FIXTURES EQUAL TO OREXCEEDING THE LISTED VALUES.HCOORDINATE AND PROVIDE LIGHTING/DIMMING CONTROLS COMPATIBLE WITHALL FIXTURES, DRIVERS, LED MODULES, ETC.IPROVIDE SELF-DIAGNOSTICS AND SELF-TESTING FOR ALL EMERGENCY FIXTURES(EXIT SIGNS, WALL PACKS, INVERTERS, ETC.).JPROVIDE A MINIMUM OUTPUT OF 900 LUMENS FOR POINT SOURCE FIXTURES AND1,200 LUMENS FOR LINEAR FIXTURES ON ALL FIXTURES DESIGNED ASEMERGENCY (CONTAINING INTERNAL BATTERY INVERTERS). PROVIDEILLUMINATION LASTING A MINIMUM OF 90 MINUTES.KVERIFY THE VOLTAGE OF ALL FIXTURES. REFER TO PLANS FOR SPECIFICVOLTAGE REQUIREMENTS.LPROVIDE FACTORY INSTALLED DISCONNECTING MEANS FOR EACH FIXTURE WITHSERVICEABLE COMPONENTS.MTHE ENGINEER RESERVES THE RIGHT TO SELECT FROM ALL AVAILABLESTANDARD COLORS FOR FIXTURES, POLES, MOUNTING ACCESSORIES, ETC.DURING SUBMITTAL REVIEW.NPROVIDE FIXTURES WITH CUSTOM COLORS/FINISH AS SELECTED BY THEENGINEER WHERE INDICATED.OPAINT AFTER FABRICATION WITH NO SHARP EDGES FOR ALL LIGHT FIXTURES.PPROVIDE APPROPRIATE SLOPE ADAPTERS, FLANGE KITS, TRIMS, AND ALL OTHERMOUNTING ACCESSORIES AS REQUIRED FOR THE CEILING TYPE.QPROVIDE SPRING-LOADED CAM LATCHES FOR ALL LINEAR FIXTURES UTILIZING AHINGED DOOR.RPROVIDE VIBRATION DAMPERS FOR ALL ALUMINUM & STEEL POLES 20’-0” ANDABOVE.SPROVIDE UL 1449, 20KV SURGE PROTECTION DEVICES FOR ALL EXTERIORFIXTURES. PROVIDE IN-LINE FUSES WITH 600 VOLT LAMP HOLDERS FOR ALLPOLE-MOUNTED FIXTURES.265119/265619/26213.1 - INTERIOR/EXTERIOR/EMERGENCY & EXIT LIGHT FIXTURES SCHEDULELABELDESCRIPTIONVOLTAGESOURCEMOUNTINGLENS/REFLECTORCERTIFICATIONSACCEPTABLE MANUFACTURERSLABELTYPELUMENSWATTSCCTL12X2 LED FLAT PANEL. 0-10V DIMMING. SELECTABLE COLOR TEMPERATURE AND LUMEN OUTPUT. SET TO 3500K AND 2,500LM.120/277 VLED2,500/3,200/4,000 LMSELECTABLE40 W3500K/4000K/5000KSELECTABLERECESSED IN GRIDSATIN WHITEDLCMETALUX CGTSCOLUMBIA CBTLITHONIA CPXL1L22X4 LED FLAT PANEL. 0-10V DIMMING. SELECTABLE COLOR TEMPERATURE AND LUMEN OUTPUT. SET TO 3500K AND 6,000LM.120/277 VLED4,000/5,000/6,000 LMSELECTABLE50 W3500K/4000K/5000KSELECTABLERECESSED IN GRIDSATIN WHITEDLCMETALUX CGTSCOLUMBIA CBTLITHONIA CPXL2X1C1LED EXIT LIGHT, WHITE FINISH, SINGLE FACE. STENCIL FACE, RED LETTERS. SELF-POWERED. NICKEL-CADMIUM BATTERY.SELF-DIAGNOSTIC/SELF-TESTING MODULE.120/277 VLEDN/A5 WN/AUNIVERSALN/AN/ASURE-LITES CXDUAL-LITE SELITHONIA LEX1C1262816.1 - ENCLOSED SWITCHES & CIRCUIT BREAKERS SCHEDULELABELLOCATIONEQUIPMENTSERVEDEQUIPMENT RATINGSACCESSORIESREMARKSNUMBERNAMEVOLTAGEPOLESAMPERAGEFUSEDFUSE SIZENEMA ENCLAUX.CONTACTSSOLIDNEUTRAL262913/262923.1 - ENCLOSED & VARIABLE-FREQUENCY MOTOR CONTROLLERS SCHEDULELABELLOCATIONEQUIPMENTSERVEDEQUIPMENT RATINGSSTARTERDISCONNECT SWITCHREMOTECAPACITORREMARKSNUMBERNAMEVOLTAGEPHASEHPFLANEMA ENCLTYPENEMA SIZETYPEFUSE SIZEMS-A1A121SCIENCE LABEF-A1120 V11/45.8 A-1----FRACTIONAL HORSEPOWER RATED TOGGLE SWITCH WITH THERMAL OVERLOADS#RevisionDate Transmittal Page 1 of 1 PROJECT:Phase One Renovations 2023-067.POR DATE:5/22/2023 SUBJECT:Coram Deo Phase 01 Bid Set TRANSMITTAL ID:00001 PURPOSE:For your use VIA:Info Exchange FROM NAME ADDRESS EMAIL & PHONE Meghan Miller Schmidt Associates 415 Massachusetts Avenue Indianapolis, IN 46204-1501 mmiller@schmidt-arch.com (317) 263-6226 TO NAME ADDRESS EMAIL & PHONE Isaac Dzula Charles C. Brandt Construction Co. 1505 North Sherman Drive Indianapolis, IN 46201 idzula@ccbrandt.com (317) 375-1111 REMARKS: DESCRIPTION OF CONTENTS QTY DATED TITLE NOTES 1 5/22/2023 2023-067.POR_FINAL MANUAL.pdf 1 5/22/2023 5.1 - General.pdf 1 5/19/2023 5.2 - Site.pdf 1 5/22/2023 5.4 - Architecture.pdf 1 5/22/2023 5.5 - Interiors.pdf 1 5/22/2023 5.7 - Mechanical.pdf 1 5/22/2023 5.8 - Plumbing.pdf 1 5/22/2023 5.9 - Electrical.pdf COPIES: Jen Carroll (Schmidt Associates) Dustin Corbett (Charles C. Brandt Construction Co.)