HomeMy WebLinkAboutC300 GRADING PLANSTM STM
STMSTMSTMSTMSTMSTMSTMSTMSTMSTMSTMSTMSTMS
T
M
S
T
M
S
T
M
S
T
M
ATM
TUBE
TUBE GGGGGGGGGE(A)E(A)E(A)E(A)E(A)E(A)E(A)E(A)E(A)E(A)E. 116th STREET
WESTFIELD BLVDOHUOHU OHU
OHU
OHU OHU
Entry
Courtyard
71.46'x61.83'
OFFICE / RETAIL SPACE
84.83'x61.83'
OFFICE/RETAIL SPACE DDDDDDDDDDDDDDDDDDDDDD
DDDD D D DDD D D DDDD
D
D
D DDDDDDDDDDDDD DDDDDDDDFFE=819.60
MFPG = 819.03
MLAG=818.83
W W W W WWWWWW
WWEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEWWWWW2
2
1
Zone XZone AEGENERAL GRADING NOTES
1.CONTRACTOR SHALL REFER TO THE STORMWATER POLLUTION PREVENTION PLAN AND DETAILS FOR
CONSTRUCTION SCHEDULING AND EROSION CONTROL MEASURES TO BE INSTALLED PRIOR TO
EARTHMOVING ACTIVITIES.
2.REFER TO THE INDIANA DEPARTMENT OF TRANSPORTATION (INDOT) STANDARD SPECIFICATIONS, LATEST
EDITION, FOR BASIC MATERIALS AND CONSTRUCTION METHODS. THE SECTIONS BELOW FOR VARIOUS
ITEMS ARE TO CLARIFY THE INTENT OF THE REQUIREMENTS FOR THIS PROJECT. PLEASE NOTE THAT
OTHER SECTIONS OF THE INDOT STANDARD SPECIFICATIONS MAY ALSO BE APPLICABLE.
3.TOPSOIL SHALL BE STRIPPED FROM ALL AREAS TO RECEIVE PAVING AND FROM WITHIN THE LIMITS OF
PROPOSED BUILDINGS AND STRUCTURES. TOPSOIL SHALL BE STRIPPED TO THE DEPTH AS NOTED IN THE
GEOTECHNICAL REPORT.
4.AFTER STRIPPING TOPSOIL, PROOFROLL AREAS TO BE FILLED WITH A MEDIUM WEIGHT ROLLER TO
DETERMINE LOCATIONS OF ANY POCKETS OF UNSUITABLE MATERIAL. RECOMMENDATIONS FOR DRYING,
AMENDING AND/OR REMOVAL OF ANY UNSUITABLE MATERIAL WITHIN THE PROPOSED PAVED AND/OR
BUILDING AREAS WILL BE DETERMINED AT THE TIME OF CONSTRUCTION BY THE OWNER'S GEOTECHNICAL
TESTING REPRESENTATIVE.
5.TOPSOIL SHALL BE PLACED IN MOUNDING AREAS, NONSTRUCTURAL FILL AND/OR PLANTING AREAS TO A
MINIMUM DEPTH OF 6". EXCESS TOPSOIL SHALL BE REMOVED FROM THE SITE.
6.WHEN PERFORMING GRADING OPERATIONS DURING PERIODS OF WET WEATHER, PROVIDE ADEQUATE
DEWATERING, DRAINAGE AND GROUND WATER MANAGEMENT TO CONTROL MOISTURE OF SOILS. REFER
TO GEOTECHNICAL REPORT AND/OR CONSULT WITH OWNER'S GEOTECHNICAL TESTING REPRESENTATIVE
FOR RECOMMENDATIONS.
7.FILL MATERIAL SHALL CONSIST OF EARTH OBTAINED FROM CUT AREAS, BORROW PITS OR OTHER
APPROVED SOURCES. EARTH SHALL BE FREE FROM ORGANIC MATTER AND OTHER DELETERIOUS
SUBSTANCES AND LARGE ROCKS. THE FILL MATERIAL SHALL BE PLACED IN LAYERS NOT TO EXCEED SIX
INCHES FOLLOWING COMPACTION, PROPER MOISTURE CONTENT OF FILL MATERIAL WILL BE SUCH TO
ACHIEVE SPECIFIED COMPACTION DENSITY. ALL FILL BENEATH PAVED AREAS, FLOOR SLABS AND FUTURE
BUILDINGS SHALL BE COMPACTED TO AT LEAST 95% OF THE MAXIMUM DRY DENSITY PER ASTM D-1557.
FIELD COMPACTING TEST SHALL BE RUN ON EACH LIFT, IN FILL SECTIONS, AND THE REQUIRED
COMPACTION ON EACH LIFT SHALL BE IN ACCORDANCE WITH INDOT SECTION 211.
8.MAXIMUM LAWN SLOPE IS 3:1.
9.THE PLANS SHOW THE LOCATION OF ALL KNOWN UTILITIES LOCATED WITHIN THE LIMITS OF CONSTRUCTION
ACCORDING TO INFORMATION PROVIDED BY THE VARIOUS UTILITY COMPANIES, PREVIOUS CONSTRUCTION
PLANS AND AS EVIDENCED BY OBSERVATION OF ABOVE GROUND CONDITIONS BY THE SURVEYOR. THE
ACCURACY OF THIS INFORMATION IS NOT GUARANTEED.
10.THE CONTRACTOR SHALL CONTACT ALL UTILITY COMPANIES TO LOCATE MAINS, CONDUITS, SERVICE LINES,
ETC. WITHIN THE CONSTRUCTION LIMITS. THE LOCATION AND PROTECTION OF UTILITY STRUCTURES,
THEIR SUPPORT AND MAINTENANCE DURING CONSTRUCTION (IN COOPERATION WITH APPLICABLE UTILITY
COMPANY) IS THE EXPRESSED RESPONSIBILITY OF THE CONTRACTOR.
11.ALL SPOT ELEVATIONS ARE TO FINISHED GRADE.
12.COMPACTED "B" BORROW BACK FILL REQ'D. OVER ALL UTILITIES IN PAVED AREAS.
13.ALL GRADES AT BOUNDARY SHALL MEET EXISTING. CONTRACTOR SHALL ADJUST AND/OR CUT EXISTING
PAVEMENT AS NECESSARY TO ASSURE A SMOOTH FIT AND CONTINUOUS GRADE. BUTT JOINTS SHALL BE
PROVIDED AT TRANSITIONAL AREAS BETWEEN PROPOSED AND EXISTING PAVEMENT.
14.ANY PART OF SANITARY OR STORM SEWER TRENCHES RUNNING UNDER OR WITHIN 5' OF PAVEMENT TO BE
BACKFILLED WITH GRANULAR MATERIAL.
15.ALL CONSTRUCTION ON THIS SITE TO BE PERFORMED IN COMPLIANCE WITH O.S.H.A. STANDARDS FOR
WORKER SAFETY.
16.THE CONTRACTOR SHALL CONFIRM ALL EARTHWORK QUANTITIES PRIOR TO THE START OF CONSTRUCTION.
IF AN EXCESS OR SHORTAGE OF EARTH IS ENCOUNTERED, THE CONTRACTOR SHALL CONFIRM WITH THE
OWNER AND ENGINEER THE REQUIREMENTS FOR STOCKPILING, REMOVAL OR IMPORTING OF EARTH.
17.PROVIDE POSITIVE DRAINAGE WITHOUT PONDING IN ALL AREAS AFTER INSTALLATION. CONTRACTOR TO
TEST FOR AND CORRECT ANY PONDING CONDITIONS. ANY AREAS THAT HOLD WATER MORE THAN 1/8"
DEEP SHALL BE CUT OUT AND CORRECTED TO POSITIVE DRAINAGE AT NO COST TO THE OWNER/
DEVELOPER OR ENGINEER.
18.ADA ACCESSIBLE PARKING SPACES, RAMPS, AND ROUTES SHALL BE IN ACCORDANCE WITH THE LATEST
ADA STANDARDS FOR ACCESSIBLE DESIGN.
19.VERTICAL CURVES, WITH A MINIMUM LENGTH OF 50', SHALL BE USED WHERE POSSIBLE BETWEEN VERTICAL
CHANGES IN DIRECTION (SLOPE) TO ALLOW FOR POSITIVE DRAINAGE AND SMOOTH TRANSITIONS.
20.CONTRACTOR TO INSTALL CONCRETE CRADLES WHEN THE VERTICAL SEPARATION (AS MEASURED FROM
THE EXTERIOR OF THE PIPES) BETWEEN SANITARY SEWER FACILITIES, WATER MAIN, AND STORM SEWERS
IS 18" OR LESS.
21.ALL DISTURBED AREA SHALL BE STABILIZED IN ACCORDANCE TO THE STORM WATER POLLUTION
PREVENTION PLAN AND LANDSCAPE PLAN.
GENERAL NOTES
1.12.THE SITE DOES LIE IN A SPECIAL FLOOD HAZARD AREA
AS ESTABLISHED BY THE FEDERAL EMERGENCY
MANAGEMENT AGENCY - NATIONAL FLOOD INSURANCE
PROGRAM, WHEN PLOTTED BY SCALE ON FLOOD
INSURANCE RATE MAP #18057C0209G, DATED NOVEMBER
19, 2014.
GRADING PLAN NOTES
ADJUST EXISTING STORM STRUCTURE CASING TO
PROPOSED GRADE
UNDERGROUND DETENTION SYSTEM. REFER TO
DETAILS ON SHEETS C603-C605.
EXISTING AREAS
PERVIOUS = 1.13 AC.
IMPERVIOUS = 0.55 AC.
PROPOSED AREAS
PERVIOUS = 0.77 AC.
IMPERVIOUS = 0.91 AC.
C300W220335-C300 grad1
2
ELECTRICAL RISER
GUY ANCHOR
ELECTRIC JUNCTION BOX
ORNAMENTAL LIGHT
GENERATOR
STREET LIGHT
ELECTRIC MANHOLE
ELECTRIC OUTLET
UTILITY POLE
UTILITY POLE W/ TRANSFORMER
TRANSFORMER
COMMUNICATIONS JUNCTION BOX
COMMUNICATIONS MANHOLE
COMMUNICATIONS PEDESTAL
RIGHT OF WAY LINE
FENCE
GUARD RAIL
BOUNDARY LINE
CISTERN
DRINKING FOUNTAIN
FIRE DEPT HOOKUP
FIRE HYDRANT
POST INDICATOR VALVE
CHILLED WATER MANHOLE
WATER MANHOLE
SPRINKLER CONTROL BOX
SPRINKLER CONTROL VALVE
SPRINKLER
SPIGOT
WELL HEAD
WATER METER
WATER VALVE
GAS METER
GAS VALVE
ELECTRIC METER
LIQUID PROPANE GAS TANK
MONITORING WELL
TRAFFIC SIGNAL POLE
TRAFFIC SIGNAL
BOLLARD
FLAG POLE
PARKING METER
POST
SIGN
PARKING WHEEL STOP
DOWN SPOUT
ACCESSIBLE SPACE
GATE POST
COMMUNICATIONS RISER
STORM CLEANOUT
BEEHIVE INLET
CURB INLET
FLOOR DRAIN
ROUND INLET
SQUARE INLET
STORM MANHOLE
SANITARY SEWER CLEANOUT
LIFT STATION
SANITARY SEWER MANHOLE
SANITARY STUB MARKER
SEPTIC TANK
PARKING LOT LIGHT (1 HEAD)
PARKING LOT LIGHT (3 HEAD)
PARKING LOT LIGHT (4 HEAD)
PARKING LOT LIGHT (2 HEAD)
HEAVY DUTY ASPHALT
CONCRETE PAVEMENT
DISTRIBUTION BOX
ROW RIGHT OF WAY
ESMT EASEMENT
D.&U.E.DRAINAGE AND UTILITY EASEMENT
FFE FINISH FLOOR ELEVATION
TC TOP OF CURB
GUT GUTTER
CMP CORRUGATED METAL PIPE
RCP REINFORCED CONCRETE PIPE
PVC POLYVINYL CHLORIDE PIPE
VCP VITRIFIED CLAY PIPE
HDPE HIGH DENSITY POLYETHYLENE PIPE
DIP DUCTILE IRON PIPE
SSD SUB SURFACE DRAIN PIPE
STM STORM
SAN SANITARY
STR STRUCTURE
CO CLEANOUT
STANDARD DUTY ASPHALT
STONE
PAVEMENT
GRADING PLAN LEGEND
UTILITIES
ABBREVIATIONS
OTHER
LINE TYPES
EXISTING SPOT ELEVATION
CURB & GUTTER ELEVATION
PAVEMENT SPOT ELEVATION
GROUND SPOT ELEVATION
FLOW LINE
INDEX CONTOUR
INTERMEDIATE CONTOUR
SANITARY SEWER MAIN
STORM SEWER MAIN
UNDERGROUND GAS
UNDERGROUND WATER
AERIAL ELECTRIC
UNDERGROUND ELECTRIC
UNDERGROUND COMMUNICATIONS
AERIAL COMMUNICATIONS
OVERHEAD UTILITY
FORCE MAIN
G G G
W W
E(A)E(A)
E E E
C C C
C(A)C(A)
OHU OHU
FM FM
AERIAL FIBER OPTIC CABLEFO(A)FO(A)
UNDERGROUND FIBER OPTICFOFO
EMERGENCY FLOOD ROUTE
SANITARY SEWER LATERALSANSAN
ROOF DRAINSTMSTM
SUB SURFACE DRAIN
CARMEL REQUIREMENTS
1.NO EARTH DISTURBING ACTIVITY MAY TAKE PLACE
WITHOUT AN APPROVED STORM WATER
MANAGEMENT PERMIT.
2.DECORATIVE SIGNS, SPRINKLER SYSTEMS, TREES,
LANDSCAPING MOUNDS, FENCES, LIGHT POLES OR
OTHER SUCH AMENITIES ARE NOT PERMITTED WITHIN
THE RIGHT-0F-WAY.
3.M.F.P.G. = MINIMUM FLOOD PROTECTION GRADE
M.F.P.G. OF ALL STRUCTURES FRONTING A POND OR
OPEN DITCH SHALL BE NO LESS THAN 2 FEET ABOVE
ANY ADJACENT 100-YEAR LOCAL OR REGIONAL
FLOOD ELEVATIONS, WHICHEVER IS GREATER, FOR
ALL WINDOWS, DOORS, PIPE ENTRANCES, WINDOW
WELLS, AND ANY OTHER STRUCTURE MEMBER
WHERE FLOOD WATERS CAN ENTER A BUILDING.
4.M.L.A.G. = LOWEST ADJACENT GRADE IS THE
ELEVATION OF THE LOWEST GRADE ADJACENT TO A
STRUCTURE WHEN THE SOIL MEETS THE
FOUNDATION AROUND THE OUTSIDE OF THE
STRUCTURE. (INCLUDING STRUCTURAL MEMBERS
SUCH AS BASEMENT WALKOUT, PATIOS, DECKS,
PORCHES, SUPPORT POST, OR PIERS, AND RIM OF
THE WINDOW WELL.
GRADE BREAK LINEFLOW DIRECTION AND SLOPE
GRADING PLANREVISIONS AND ISSUESPart of the NW/4 of Section 06, Township 17 North, Range 4 East, Delaware Township, Hamilton County, IndianaW220335PREPARED FOR:1701 E. 116TH STREET PROJECT NO.
SHEET NO.CHECKED BY:DRAWN BY:TASDESIGNED BY:DWG NAME:PROJECT NO.:W220335DATEBY09.14.2022SSRDATE:TASKnow what's below.
before you dig.Call
R APPROVAL PENDINGNOT F
OR C
O
NSTR
UCTI
O
N
CARMEL OFFICE BUILDINGRevised site based on Carmel comments and building changes2023-02-24SR/MSREVISIONS PER ADLS REVIEW 2023-06-05SSRSTEVEN SCOTT RUCKER P.E. 11300279ENGINEERS317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546 faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild with confidence.SM06/05/2023
W
S
N
E
CLOGGED INLET PONDING AREA
STORM SEWER DATA
REFER TO C601 - UTILITY PLAN FOR DETAILED STORM
STRUCTURE AND PIPE INFORMATION.
ALL PROPOSED STORM SEWERS ARE A PRIVATE STORM
SEWER SYSTEM.
UNDERGROUND DETENTION SYSTEM
TOP OF STONE - 809.55
TOP OF CHAMBER - 816.55
BOTTOM OF CHAMBER - 809.55
BOTTOM OF STONE BASE - 808.55
DETENTION VOLUME = 19,622.49 CUFT
DRAINAGE ANALYSIS
DESIGN AREA
CAPTURED = 0.90 Ac
ALLOWABLE RELEASE RATES
Q10post = 0.09 cfs
Q100post = 0.27 cfs
PROPOSED RELEASE RATES
10-YEAR = 0.09 cfs
100-YEAR = 0.27 cfs
REQUIRED DETENTION VOLUME
CAPTURED AREA = 11.833 cf
PROVIDED = 11,958 cf
DESIGNED STORAGE ELEVATIONS:
10-YR: 813.74
100-YR: 816.54
INSTALLED SYSTEM STORAGE ELEVATIONS:
10-YR: 812.63
100-YR: 815.04
FLOOD PROTECTION
100-YEAR STAGE ELEVATION = 814.70
EMERGENCY OVERFLOW WEIR = 815.40
MINIMUM LOWEST ADJACENT GRADE
MLAG = 818.83
NEAREST FLOODWAY = CARMEL CREEK
APPROXIMATELY 237' OFF-SITE
NEAREST BASE FLOOD ELEVATION = 815
MINIMUM FLOOD PROTECTION GRADE
MFPG = 819.03
EMERGENCY OVERFLOW
FLOOD ZONE LIMITS PER RECORD
(SHOWN FOR REFERENCE ONLY)