8 20453ATM
TUBE
TUBE GGGGGGGGGE(A)E(A)E(A)E(A)E(A)E(A)E(A)E(A)E(A)E(A)E. 116th STREET
WESTFIELD BLVDOHUOHU OHU
OHU
OHU OHU
Entry
Courtyard
71.46'x61.83'
OFFICE / RETAIL SPACE
84.83'x61.83'
OFFICE/RETAIL SPACE DDDDDDDDDDDDDDDDDDDDDD
DDDD D D DDD D D DDDD
D
D
D DDDDD DDDDDDDD DDDDDDDD6
FFE=819.60
MFPG = 819.03
MLAG=818.83
W W W W WWWWWW
WWEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEWWWWWG1
G2
E1
E2
W1
W2
W6
W3
EXISTING 12" WATER
(NOT LOCATED)
EXISTING 6" WATER
NOTE: UTILITY CONNECTIONS ARE
APPROXIMATE. MEP PLANS NOT
AVAILABLE AT TIME OF SUBMITTAL.
E1
E1
E1
E3
W5
W8
W7
W4
SS3
SS3
SS1
SS2
C2
W9
W10
W12
W11
W11
STM STM STM STMDDDDD
DDDDDDDDW W W
WWWWWWWWWWWWW1
W2
W6
W3
W5
W8
W7
W4
SS3
W9
W10
W12
W11
W11
UTILITY PLAN NOTES
SANITARY SEWER NOTES
CONNECT PROPOSED 6" SANITARY SEWER LATERAL TO EXISTING
SANITARY SEWER. COORDINATE CONNECTION WITH MEP AND
SERVICE PROVIDER. PROVIDE CLEANOUTS AS REQUIRED/SHOWN.
VERIFY INVERTS ON EXISTING LINE AND COORDINATE CONDITIONS
WITH MEP. ADJUST AS REQUIRED.
EXISTING 8" SANITARY SEWER.
PROPOSED SANITARY LATERAL CLEANOUT TYPE 1 WITHIN 3' OF
BUILDING. REFER TO DETAIL ON SHEET C801.
PROPOSED SANITARY LATERAL CLEANOUT TYPE 2 OUTSIDE OF 3' OF
BUILDING. REFER TO DETAIL ON SHEET C801.
GREASE INTERCEPTOR, REFER TO PLUMBING PLANS FOR DETAILS.
PROVIDE 18" MINIMUM VERTICAL CLEARANCE BETWEEN
SANITARY/WATER/STORM SEWER PIPES AND ALL OTHER PIPES.
INSTALL CONCRETE CRADLE IF CLEARANCE IS LESS THAN 18"
WATER SERVICE NOTES:
COORDINATE AND CONNECT 6" FIRE SERVICE LINE TO EXISTING 6"
SERVICE LINE.
COORDINATE CONNECTION OF DOMESTIC SERVICE LINE AND FIRE
SERVICE LINE WITH PLUMBING DRAWINGS.
INSIDE METER(S) AND BACKFLOW PREVENTION REQUIRED.
COORDINATE WITH MEP PLANS.
PROPOSED FIRE HYDRANT LOCATION. COORDINATE WITH
CARMEL UTILITIES.
COORDINATE AND CONNECT 2" DOMESTIC SERVICE LINE.
2" ISOLATION VALVE.
6" DRY LINE FOR FIRE DEPARTMENT CONNECTION.
FIRE DEPARTMENT CONNECTION (FDC).
NEW 6" X 6" TEE FITTING.
NEW 6" X 2" TEE FITTING.
NEW 6" FIRE SERVICE LINE.
INSTALL PIV ON BUILDING FIRE SERVICE LINE.
ELECTRIC NOTES:
COORDINATE AND CONNECT BUILDING ELECTRICAL LINE FROM
SERVICE DROP LOCATION TO TRANSFORMER. COORDINATE
CONNECTION WITH POWER COMPANY AND ELECTRICAL DRAWINGS.
ADJUST AS REQUIRED. 2-4" EC CONDUITS TO BE INSTALLED WITH
PULL STRINGS, 36" DEPTH. 120/208V, 3 PHASE, 1200 AMP ELECTRIC
REQUIRED.
EXISTING TRANSFORMER PAD LOCATION.
PROPOSED TRANSFORMER PAD (TO BE SIZED). COORDINATE WITH
UTILITY PROVIDER IF A NEW TRANSFORMER IS REQUIRED.
COMMUNICATION NOTES:
CONNECT BUILDING COMMUNICATION SERVICE LINE(S) TO
CONNECTION POINT AS SHOWN. ADJUST AS REQUIRED. 4" PVC
CONDUIT TO BE INSTALLED WITH PULL STRINGS. COORDINATE WITH
PROVIDER AND BUILDING MEP PLANS.
COORDINATE WITH SERVICE PROVIDER FOR RELOCATION OF
PEDESTAL.
GAS SERVICE NOTES:
CONNECT PROPOSED GAS SERVICE TO EXISTING GAS LINE. REFER
TO PLUMBING DRAWINGS AND COORDINATE WITH SERVICE
PROVIDER.
PROPOSED GAS METER LOCATION. REFER TO PLUMBING DRAWINGS
AND COORDINATE WITH SERVICE PROVIDER.
W4
W2
W3
SS3
SS2
W1
SS4
E1
E2
C1
G1
SS1
SS6
SS7
ELECTRICAL RISER
GUY ANCHOR
ELECTRIC JUNCTION BOX
ORNAMENTAL LIGHT
GENERATOR
STREET LIGHT
ELECTRIC MANHOLE
ELECTRIC OUTLET
UTILITY POLE
UTILITY POLE W/ TRANSFORMER
TRANSFORMER
COMMUNICATIONS JUNCTION BOX
COMMUNICATIONS MANHOLE
COMMUNICATIONS PEDESTAL
RIGHT OF WAY LINE
FENCE
GUARD RAIL
BOUNDARY LINE
CISTERN
DRINKING FOUNTAIN
FIRE DEPT HOOKUP
FIRE HYDRANT
POST INDICATOR VALVE
CHILLED WATER MANHOLE
WATER MANHOLE
SPRINKLER CONTROL BOX
SPRINKLER CONTROL VALVE
SPRINKLER
SPIGOT
WELL HEAD
WATER METER
WATER VALVE
GAS METER
GAS VALVE
ELECTRIC METER
LIQUID PROPANE GAS TANK
MONITORING WELL
TRAFFIC SIGNAL POLE
TRAFFIC SIGNAL
BOLLARD
FLAG POLE
PARKING METER
POST
SIGN
PARKING WHEEL STOP
DOWN SPOUT
ACCESSIBLE SPACE
GATE POST
COMMUNICATIONS RISER
STORM CLEANOUT
BEEHIVE INLET
CURB INLET
FLOOR DRAIN
ROUND INLET
SQUARE INLET
STORM MANHOLE
SANITARY SEWER CLEANOUT
LIFT STATION
SANITARY SEWER MANHOLE
SANITARY STUB MARKER
SEPTIC TANK
PARKING LOT LIGHT (1 HEAD)
PARKING LOT LIGHT (3 HEAD)
PARKING LOT LIGHT (4 HEAD)
PARKING LOT LIGHT (2 HEAD)
HEAVY DUTY ASPHALT
CONCRETE PAVEMENT
RIGHT OF WAY PAVEMENT
DISTRIBUTION BOX
ROW RIGHT OF WAY
ESMT EASEMENT
D.&U.E.DRAINAGE AND UTILITY EASEMENT
FFE FINISH FLOOR ELEVATION
CMP CORRUGATED METAL PIPE
RCP REINFORCED CONCRETE PIPE
PVC POLYVINYL CHLORIDE PIPE
VCP VITRIFIED CLAY PIPE
HDPE HIGH DENSITY POLYETHYLENE PIPE
DIP DUCTILE IRON PIPE
SSD SUB SURFACE DRAIN PIPE
STM STORM
SAN SANITARY
STR STRUCTURE
CO CLEANOUT
STANDARD DUTY ASPHALT
STONE
PAVEMENT
UTILITY PLAN LEGEND
UTILITIES
ABBREVIATIONS
OTHER
LINE TYPES
FLOW LINE
SANITARY SEWER MAIN
STORM SEWER MAIN
UNDERGROUND GAS
UNDERGROUND WATER
AERIAL ELECTRIC
UNDERGROUND ELECTRIC
UNDERGROUND COMMUNICATIONS
AERIAL COMMUNICATIONS
OVERHEAD UTILITY
FORCE MAIN
G G
W W
E(A)E(A)
E E
C C
C(A)C(A)
OHU OHU
FM FM
AERIAL FIBER OPTIC CABLEFO(A)FO(A)
UNDERGROUND FIBER OPTICFOFO
SANITARY SEWER LATERALSANSAN
ROOF DRAINSTMSTM
SUB SURFACE DRAIN
C2
G2
C800W220335-C800 Utility PlanUTILITY PLANREVISIONS AND ISSUESPart of the NW/4 of Section 06, Township 17 North, Range 4 East, Delaware Township, Hamilton County, IndianaW220335PREPARED FOR:1701 E. 116TH STREET PROJECT NO.
SHEET NO.CHECKED BY:DRAWN BY:TASDESIGNED BY:DWG NAME:PROJECT NO.:W220335DATEBY09.14.2022SSRDATE:TASKnow what's below.
before you dig.Call
R APPROVAL PENDINGNOT FOR CONSTRUCTIONCARMEL OFFICE BUILDINGRevised site based on Carmel comments and building changes2023-02-24SR/MSREVISIONS PER ADLS REVIEW 2023-06-05SSRSTEVEN SCOTT RUCKER P.E. 11300279ENGINEERS317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546 faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild with confidence.SM06/05/2023
W
S
N
E
E3
W5
W6
W7
W8
WATER CONNECTION DETAIL
SCALE: 1"=10'
W9
W10
W11
W12