P1.1 First Floor Plumbing Plan
ATMSD VAULT(8)StacksP1.1REVISIONBMO Bankand Commercial Building1st Floor Plumbing PlanTMI Mechanical, LLCResidential / CommercialPlumbing * Heating * Air Conditioning * RefrigerationMechanical Contractor1701 E 116th St, Carmel, IndianaPLUMBING NOTES “” ” ” MCCREARY CONCRETE PRODUCTS, INC. RUSHVILLE & TIPTON, INDIANA 1000 GALLON COMMERCIAL GREASE/OIL/SEDIMENT INTERCEPTOR H20 LOAD BEARING 2-COMPARTMENT 765-932-3058 TRAFFIC RATED, 7" MINIMUM, 5' 0" MAXIMUM COVER CARMEL, INDIANA SPECIFICATION COMPLIANT 7" HT. 8172 TYPE FRAMES & GREASE TRAP LIDS / HEAVY DUTY 6" CAST-A-SEAL GASKETED INLET 8" SIDE VIEW 7" LIQUID LEVEL 36" 6" CAST-A-SEAL GASKET OUTLET 8" min- *based on flows 74" 53" 6" SDR35 DROP LEG MONOLITHIC CONTAINMENT BAFFLE 30"SEDIMENT HOLDING COMPARTMENT 72" 114" STRUCTURE IS PRODUCED USING PENETRON ADMIXTURE. A CORROSION INHIBITOR AND CRYSTALINE SEALER. BASE SECTION------------------------9,375 LBS. RISER SECTION-----------------------7,650 LBS TOP SLAB------------------------------5,700 LBS. STRUCTURE WEIGHT TOTAL----22,725 LBS. 6"36" 6"pipe sleeve 50" 40" 6" SDR35 DROP LEG *Stainless pipe support provided but installed by others, 6" diam. 6" MIN- *BASED ON FLOWS 6" BASE SLAB GT-1 DETAIL 19"TOP VIEW STRUCTURE TO BE SEALED IN THE FIELD WITH A SINGLE ROW OF 1.2" HT. X 1.5" W. CONSEAL RUBBER BUTYL STRIP SEALANT 72"24"24" 19" 36" 114"