Loading...
HomeMy WebLinkAboutC6.2_Bulletin 1131ST STREET TOWNE ROADCONTRACTOR TO INSTALL NEW OUTLET CONTROL STRUCTURE WITH 8.0" ORIFICE OVER EXISTING 18" OUTLET . SEE DETAIL THIS SHEET 904 903 902 901 900 899 905904903902901900899899 900 901 902 903 904 8999009019029039049059059059 0 5 905905 905 TOP OF BANK = 904.40 TOP OF BANK = 904.40 EXISTING HARLESTON POND 5 TOWNE ROADSTR. 100 RIM=906.52 INV(S)=900.59 (24" RCP) INV(N)=901.49 (12" RCP) INV(E)=900.49 (24" RCP) STR. 100A RIM=905.52 INV(S)=901.65 (12" RCP)TOWNE ROADMSANITARY CLEANOUT FDC PIV TRANSFORMER PAD COORDINATE W/ UTILITY EXISTING STORM STRUCTURE TO BE CORE DRILLED, CONNECTION TO BE SEALED WITH NON SHRINK GROUT AND ENTIRELY ENCASED IN CONCRETE ON EXTERIOR OF EXISTING STRUCTURE. WATER METER 2" TYPE K COPPER DOMESTIC SERVICE LINE 36' - 24" RCP @ 0.20% STR. BMP RIM=905.60 INV(W)=900.47 (24" RCP) INV(E)=900.37 (24" RCP)49' - 12" RCP @ 0.32%10' - 24" RCP @ 0.20% HORIZONTAL SCALE: 1"=20' VERTICAL SCALE:1"=5' 890 895 900 905 910 915 920 890 895 900 905 910 915 920 0+00905.3906.52INV.=900.59 S (24" RCP)INV.=901.49 N (12" RCP)INV.=900.49 E (24" RCP)STR. #100 - 60" MANHOLERIM.=906.5249' - 12" RCP @ 0.32%INV.=901.65 S (12" RCP)STR. #100A - 2' X 3' INLETRIM.=905.523850 Priority Way South Drive, Suite 110Indianapolis, IN 46240Phone: (317) 779-2194NO.DATEREMARKSFILENAME: DATE: JOB NO. SHEET 02/14/2023 12357 ACE HARDWAREVillage of WestClay2425 HARLESTON STREET, CARMEL, IN 46032FILENAME: 12357_C6.0 UT SCALE 1" = 20' 200 40 N R CERTIFIED BY106/06/2023REVISIONS PER TAC REVIEW207/07/2023ADDENDUM 2307/07/2023ISSUED FOR CONSTRUCTION408/11/2023BULLETIN 1STORM PROFILES AND OFF-SITE IMPROVEMENTSC6.2 OFF-SITE DRAINAGE IMPROVEMENTS SCALE: 1" = 30' GRANULAR BACKFILL PER CARMEL DRAWING 10-31 EXISTING GRADE PROPOSED GRADE HYDRAULIC GRADE LINE PROFILE LEGEND: NOTE: THE STORM SEWER SYSTEM SHALL BE CONSTRUCTED PER DESIGN SPECIFIED AND AS APPROVED BY THE CITY OF CARMEL ON THE FINAL APPROVED CONSTRUCTION PLANS. DEVIATIONS FROM THE APPROVED DESIGN SHALL ONLY BE PERMITTED DUE TO SPECIAL CIRCUMSTANCES OR DIFFICULTY DURING CONSTRUCTION AND WILL REQUIRE PRIOR FIELD APPROVAL FROM A DESIGNATED REPRESENTATIVE OF THE CITY OF CARMEL IN ADDITION TO SUPPLEMENTAL APPROVAL BY THE DESIGN ENGINEER. AN EXPLANATION OF ANY SUCH DEVIATION SHALL BE INCLUDED AS A REQUIREMENT ON AS-BUILT/RECORD DRAWINGS SUBMITTED FOR RELEASE OF PERFORMANCE GUARANTEES. APPROVED DESIGN SLOPES IDENTIFIED AS GENERATING VELOCITIES OF 2.5 FPS OR LEE OR 10 FPS OR GREATER (AT FULL FLOW CAPACITY) SHALL REQUIRE AS-BUILT CERTIFICATION AT THE TIME OF CONSTRUCTION, PRIOR TO BACKFILLING THE PIPE. THE CONTRACTOR IS INSTRUCTED TO AS-BUILT EACH SECTION OF STORM PIPE AS IT IS BEING INSTALLED TO ENSURE COMPLIANCE WITH THE DESIGN PLANS AND AS APPROVED BY THE CITY OF CARMEL PROVIDE AND INSTALL 52" GALVANIZED STEEL GRATE. GRATE WILL BE A 19-W-4 LIGHT DUTY WELDED STEEL GRATING WITH A 1" BY 3 18" THICKNESS AND ANCHORED TO STRUCTURE TOC = 903.20 8" DIA. ORIFICE IN BOX @ 897.98 NORMAL POOL = 897.98 EXISTING 18" RCP @ 897.98 TOC = 903.20 INV = 897.98 EXISTING 18" RCP SECTION A-A SECTION B-B 48" OUTLET CONTROL STRUCTURE NTS 48" 4 4