Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A301
A. B. C. D. E. F. G. H. I. J. ALL EXPOSED STEM WALLS SHALL BE OF MASONRY TYPE INDICATED FOR WALL ABOVE FLOOR LINE. SIDEWALKS AT BUILDING AND STRUCTURES SHALL MATCH FINISH FLOOR AT DOORS AND SLOPE AWAY. SEE STRUCTURAL DRAWINGS FOR ADDITIONAL INFORMATION. SUSPENDED MATERIALS SHALL BE ATTACHED TO STRUCTURE BY "SHEAR" CONNECTIONS; "PULL- OUT" CONNECTIONS ARE NOT ALLOWED. BATT. INSULATION SHALL BE CONTINUOUS UNDER ENTIRE ROOF PLANE AND SHALL LAP WALL INSULATION. WALL INSULATION SHALL BE CONTINUOUS. ROUTE ALL PLUMBING, FIRE SPRINKLER, MECHANICAL, ELECTRICAL, FIRE ALARM, PIPING, AND CONDUIT IN CONCEALED OR FURRED AREA ONLY. EXPOSED PIPING AND CONDUIT SHALL NOT BE ALLOWED IN ANY AREA EXCEPT AT ELECTRICAL AND FIRE RISER ROOMS. PAINT ALL EXPOSED METAL THAT IS NOT SPECIFIED OR INDICATED TO RECEIVE FACTORY FINISH. PROVIDE MASONRY LINTEL BLOCKS AT HEADS OF ALL MASONRY OPENINGS. SEE PLANS AND SCHEDULE FOR DOOR AND WINDOW TYPES AND SIZES. ALL EXPOSED FLASHING SHALL BE FACTORY FINISHED BY MANUFACTURER/SUPPLIER OF MATERIAL WHICH IS BEING FLASHED. GENERAL BUILDING SECTION NOTES: FIN FLOOR +0' - 0" TRUSS BEARING +13' - 9" T.O. PARAPET (LOW) +23' - 0" T.O.PARAPET (MID) +24' - 6" A-302 2ACBA-302 2 REV. 8 6 12 11 1 3 14 6 8 1615 17 1 3 17 1513 1918 FIN FLOOR +0' - 0" TRUSS BEARING +13' - 9" T.O. PARAPET (LOW) +23' - 0" T.O.PARAPET (MID) +24' - 6" A-302 4 1' - 6"9' - 3"13' - 9"ACB A-302 4 REV. 9912 11 1717 33 19 18 FIN FLOOR +0' - 0" TRUSS BEARING +13' - 9" T.O. PARAPET (LOW) +23' - 0" 162345 127111098A-303 2 A-303 2 REV. 4 7 11 211 1 3 6 8 17 6.5 12 1918 12 19181919 FIN FLOOR +0' - 0" TRUSS BEARING +13' - 9" T.O. PARAPET (LOW) +23' - 0" T.O.PARAPET (MID) +24' - 6" T.O.PARAPET (HIGH) +26' - 0" A-302 1 ACB A-302 1 REV. 2 12 11 17 2 17 19 18 FIN FLOOR +0' - 0" TRUSS BEARING +13' - 9" T.O. PARAPET (LOW) +23' - 0" T.O.PARAPET (MID) +24' - 6" T.O.PARAPET (HIGH) +26' - 0" A-302 3 1' - 6"1' - 6"9' - 3"13' - 9"ACBA-302 3 REV. 1012 11 1 13 6 5 10 1 13 6 5 661918 1. ALUMINUM STOREFRONT SYSTEM, COLOR: DARK BRONZE 2. EXTERIOR INSULATION FINISHING SYSTEM, TEXTURE: SMOOTH, PAINT COLOR: CREAM WITH REVEALS, PAINT COLOR: DARK BRONZE 3. EXTERIOR INSULATION FINISHING SYSTEM WAINSCOTT, TEXTURE: SMOOTH, COLOR: STONE 4. CAST STONE MASONRY WAINSCOTT, 8" H X 24" W X 4" D (NOMINAL), COLOR: NATURAL 5. INSULATION FINISHING SYSTEM CHEVRON RADIUSED CANOPY, TEXTURE: SMOOTH, COLOR: ART DECO RED 6. INSULATION FINISHING SYSTEM COPING, TEXTURE: SMOOTH, COLOR: DARK BRONZE 7. INSULATION FINISHING SYSTEM RECESSED HALF ROUND HORIZONTAL BAND COPING, TEXTURE: SMOOTH, COLOR: STONE 8. INSULATION FINISHING SYSTEM RECESSED PANELS, TEXTURE: SMOOTH, COLOR: DARK BRONZE 9. FLUTED EXTERIOR INSULATION FINISHING SYSTEM PILASTERS, TEXTURE: SMOOTH, COLOR: STONE 10. FLUTED EXTERIOR INSULATION FINISHING SYSTEM RECESSED PANEL, TEXTURE: SMOOTH, COLOR: ART DECO RED 11. WOOD TRUSS 12. CLASS 'A' ROOF MEMBRANE SYSTEM 13. AUTOMATIC SLIDING DOOR 14. ROOF ACCESS HATCH 15. HOLLOW METAL DOOR, COLOR: DARK BRONZE 16. COILING SECTIONAL DOOR, COLOR: DARK BRONZE 17. DAINOLITE DAYANA 1 GLOBE LIGHT OR EQUAL, COLOR: DARK BRONZE 18. ROOFTOP MECHANICAL UNIT - SHOWN FOR REFERENCE ONLY 19. LINE OF PARAPET BEYOND. BUILDING SECTION KEYNOTES: FIN FLOOR +0' - 0" TRUSS BEARING +13' - 9" T.O. PARAPET (LOW) +23' - 0" 162345 127111098A-303 1 A-303 4 4 7 11 2 15 7 2 12 11 6.5 1918 12 19181919 ARCHITECT 5253 W 16th Street Speedway, IN 46224 info@ovalis.com 317.215.5151 SEAL ISSUE DATE SHEET CONTENTS PROJECT PHASE DRAWN BY PROJECT NUMBER SHEET NUMBER REVISIONS © 2021Autodesk Docs://2021055_Village of WestClay - Ace Hardware/2021055_2023_VILLAGE OF WESTCLAY - ACE HARDWARE.rvtVILLAGE OF WEST CLAY - ACE HARDWARE2425 HARLESTON STREETCARMEL, IN 46032A-301 2021055 BUILDING SECTIONS PERMIT/BIDDING 04/20/2023KENNMARSCALE: 3/32" = 1'-0"1TRANSVERSE BUILDING SECTION 1 SCALE: 3/32" = 1'-0"2TRANSVERSE BUILDING SECTION 2 SCALE: 3/32" = 1'-0"6LONGITUDINAL BUILDING SECTION 1 SCALE: 3/32" = 1'-0"4TRANSVERSE BUILDING SECTION 4 SCALE: 3/32" = 1'-0"3TRANSVERSE BUILDING SECTION 3 11 TAC REVIEWTAC REVIEW COMMENTSCOMMENTS 04/28/202304/28/2023 SCALE: 3/32" = 1'-0"5LONGITUDINAL BUILDING SECTION 2 11 1 1 11 1 1 11 1111 111 1 1 1