HomeMy WebLinkAboutC102 Rev 4-28-21INV S=841.38 INV N=841.58 I STM STM I V) TI co O EX BLIND TIE _D3- STM INV. 841.50 FBOP INV S=841.56 INV N=841.72 INV E=846.15 EX. STORM INLET T.C. = 850.21 cn W I I \ Ib \ r� I 11 I V) 1 II I 11 M.E. 8 1 F EX. STORM INLET T.C. = 847.76 INV 15" RCP NW = 843.53 INV 15" RCP NE = 843.81 STM STM STM M s2� s s> INGRESS/EGRESS EASEMENT 1 EX. SToORMIMANHOLEs 1 ASSUMED NORTH NST. #8907337 & 8907338 INLET 108 T.C. =6.19 1 INY, 24" RCP NW = 841'89. 0.415ACf GUT=849.46 1 INV.�24� RCP NE = 841.89 SCALE. 1 "- 30 ' INV S=845.76 1 INV. 24'-RCP S = 841.89 i / • • • :._'dry,' • :Mi:41.7 i i�6] • i�'7� i i - :..i:��� - - - - - - i e [[•��.'.//����R. \ o COD DUMP- Epp I Ln STER f INLET 117 / INLET 116 849. \ 00 INLET 118 TC=849.50 / O TC=849.22 \ 1 I I TC=849.50 I INV E=845.40 INV S=844.48 v' 84 . 4 INV E=845.82 849 90 INV W=845.50 / INV W=844.58 - c"! I I \TRASH 849.96 i 849 �' co . P.AQ_ 849.89 849.95 -12" RCP 126'-12" RCP 851.6 8 9.90 849.98 1 I cj0��/ 852.46 11 \ \ 850 849.59 �� ' 850 FFE - 852.50 0 851.68 850.17 , i 850:00 i 849.57 0 0� ENC. 849. 6 6.9 r r�A ono. \ ado o 00 00 M E I EX. 4" IGH PRESSURE 845. I (60 PSI GAS LINE. LOCATED 9d% o IIN WASI INGTON BLVD; APPROX. \ I N. 1 9' WES OF CENTERLINE AT A DEPTH F APPROX. 3' BELOW GRADE. 849.46 I NOTE: ROM WEIHE ENGINEERS INC. 6 99 I LAND T TILE SURVEY PENNWOOD OFFICE ®� 849.62 F i PARK F 4. DATED 4-25-1990. MFPG = 851.50 - I 1 = \ 1 0 MLAG - 852 00 �` RED -------------------- ------------------------rt----------- s - - - - - 74 1 00 rn f �n 850.13 851.68 I \ .72 851.00 851.6Q 850. BMP ACCE� - - 850.50 850.60 851.00 ° 851.00 00 j i i E. 45. ;o I m 50 I EX. ST RM MANHOLE T.C. = 844.40 I I I I INV 24 RCP N= 841.80 INV 24 RCP SW = 841.80 I I 8 13 �' I I I� EX. MANHOLE 111 II TC=844.40 /-.d- I' INV N=841.8000 I } 1 I NEW INV S=841.70 / I 0000 o I I 00 e � b I 21 I MANHOLE 113 I / TC=851.70 I INV SW=843.48 IN, N=843.58 i I i / -----------------------' -' I 1 851.40 / 850.35 850.89 I / / �` 852 - - - - - - - - -� w 851 BMP 104 850 849 _ _ I rMA1 HOLE 110 I I / / _ - / = / ®� I / 15'-12' RCP TC 84 / / -__ l--848----- - - - - -- 847 IINV SW.50 851.00 5 /INV=844.05 . • / END SECTION 112� 846 e/ [INV SW=841.40 / @ 2.95% _.RM / 1 NW=844.15,�- - - --�- -_-- --------------- INV OUT-843.30 845 � 1 INV N=841.50 n ___ __ _ _ ____ I I � T INV. = 8 �'�-----_----____ --------_ TB _---------=TB- - 8 SY RIP- 8 844 I I I 850.60 / g� 2 0. i ����-- - -- q-------- '-� N --------- - a•'`.a ../�. ..i�'� _a• :4 C14 d� ®®fir--- --ate ---�-----�� ®� '•o 1cp11 I ^��� EX. PIPE END 103 PIPE END 109 841.54 1 I I I I l 1 INLET 106 848.90 INLET 105 848. 5 I' ,, EX. INV = 841.40 W/ 24" FLAP GATE J1 1\ TC=849.20 I (REPLACE STRUCTURE) ♦ I III I /\ EDGE OF WATER INV OUT=841.30 SS \ INV E=845.49 RAISEINV SE=844.59 8 4 r' I �I I I j I `INV. 841.40 8 SY RIP -RAP \ 1 1 ® \ I 1 SS // \� INV N=844.86 II 1 - INV W=845.09 I I 1 O \��� SS � 84 .28 a a. � `INV. 841.10 • j 1 11 11 aI , - C , III r• 10-YR POND ELEVATION = 843.31 i1 11� w ( INST. #8907337 EASEME38 NTIIII / s (,�A I I IIIII r 100-YR POND ELEVATION = 845.50 ;i 'i / m INST. #8907337 & 89073381 / 1 Q \ III 11I I OUTLET 102 LU J 10.415ACf i LHX. - IJ 11�1 I TC=845.50 RETENTION POND EASEMENT m SANITARY MAN OL 1¢ d �I O�� �8"ORIFICEINV=841.30 INST. #8907337 & 8907338 = -LQ'1416J 12" INV OUT=841.30 CO O2fi-1'as I / - - - - - -I v Pvc s 838.50 cn I I 1 N65 POND OVERFLOW THROUGH OUTLETlip- II \ / / I M.E. I I I II I �I 111• I ID I I I 1I III INV. 841.18 PIPE END 119 / �I ► I i / I I � -_-- / 848.12 III I 1 l� --___-�---__--= INV. 841.99 I/ I IP 1 1 / - W/ 12" FLAP GATE �!\� III EDGE OF WATER INV OUT=842.78 I I N - \\\�;'�� = --_�iti - 5 SY RIP -RAP I // 11 I ap �- 46 - - - «���: - 24' of 12" i /-----------------------------_ - _ RC" -3= a46 a45 �f 111 ICI ---------849--- y I END SECTION 120 I I INV IN=843.50 5 SY RIP -RAP 00o STORM SEWER TABLE (PRIVATE SYSTEM) GRADING AND DRAINAGE NOTES M.E. I M.E. STM - EX. STORM INLET T.C. = 851.44 CV 0 o IN EX. SANITARY MANHOLE I I DOGHOUSE MH 101 TC=851.27 +/- 21" RCP INV=841.27 +/- (FIELD VERIFY) INV E=841.30 - - - - I-- - - SEE R/W TRENCHING DETAIL I& PAVEMENT REPAIR DETAIL ON SHEET C802. I I sJ - N 00 852.46 \r 852.46 1� D I / 12" PIP s C.O. INV.CD o _ I 848.50 6 N .. REMOVE EX. `s>� L 00 RI POND OUTLET a UNDER BUILDING g5 46 , N a c'cl, - N Q�7Ar GS INDICgTE 850.85-- I d- \ --- I -- ��1--MINT -------------------- - - - - ----------- 851 � II 851.68I I _ I I _00700-� ro 851.35 I 4;_1 851.58 / N�__ 851.58 851.30 851.58 851.58 851.58 __851.2851.58I 51 IF 6' PVC a .... ,. 1.96% o 2.0 852. 852.0 852.1 .4'.. 852.16 852.1 � 852.16 852.3 85 .16 i i 852.16 <` 852.3 I 51.00 851.68 ANHOLE 107 a.. /' 2.46 852.46 52.25 ' 52.46 852.46 852.46 852.3 852.46 MANHOLE 115 TC=851.00 �� TC=851.70 S=845.34 °crN° INV S=843.97 0851NV '68 11V N=845.44 .a INV N=844.07 I�V W=847.40 o <I/ // /� // /, INV W=845.17 852 - _ 852.4 10'-18" RCP @BMP514 851.42 I 850.90f' FFE 852 50 FIFE= 852.50 I 52.34 '.. ! / - / TC=851.70 MFPG = 851.50 / MFPG = 851.50� INV S-843.82 ` 851.42 22 i/ //MLAG = 852.00 // o --�tA�-_8J�.00 INV N=843.92/ 1.70 851.76 / / 00 CO ffvv I 850.68 s �DK al: u ^ ^ / 852.0 237 LF 6" PVC ROOF DRAIN @ 1.41% 846.k4 1. ALL GRADES AT BOUNDARY SHALL MEET EXISTING GRADES. 2. SITE GRADING SHALL NOT PROCEED UNTIL EROSION CONTROL MEASURES HAVE BEEN INSTALLED. 3. ALL SWALES SHALL HAVE A MINIMUM SLOPE OF 1.00%. 4. CONTRACTOR SHALL MINIMIZE DAMAGE TO EXISTING TREES. 5. SLOPES SHALL NOT BE GREATER THAN 3:1 UNLESS OTHERWISE SPECIFIED. 6. REMOVE AND BACKFILL ALL AREAS WHERE ANY FIELD TILE CROSSES PROPOSED BUILDING PADS. ALL FIELD TILES INTERCEPTED TO BE PERPETUATED INTO STORM SEWER SYSTEM. THE SUBCONTRACTOR SHALL NOTIFY IN WRITING THE OWNER AND THE ENGINEER IN ANY CIRCUMSTANCES WHERE THIS CANNOT BE ACCOMPLISHED. 7. FILL PLACED ON -SITE SHALL BE COMPACTED TO 95 PERCENT STANDARD PROCTOR DENSITY (ASTM D-698). REFER TO PROJECT GEOTECHNICAL REPORT FOR ADDITIONAL REQUIREMENTS. 8. THE CONTRACTOR SHALL CONFIRM ALL EARTHWORK QUANTITIES PRIOR TO THE START OF CONSTRUCTION. IF AN EXCESS OR SHORTAGE OF EARTH IS ENCOUNTERED, THE CONTRACTOR SHALL CONFIRM WITH THE OWNER AND ENGINEER THE REQUIREMENTS FOR STOCKPILING, REMOVAL OR IMPORTING OF EARTH. 9. ALL STORM SEWER TRENCHES ARE TO BE BACKFILLED WITH GRANULAR MATERIAL. 10. STANDARD SPECIFICATIONS FOR THE LOCAL GOVERNING AUTHORITY SHALL APPLY FOR ALL STORM SEWER CONSTRUCTION. 11. MAXIMUM SLOPE OF 2.00% IN HANDICAPPED PARKING AREAS. 12. ROOF DRAINS AND FOUNDATIONS DRAINS TO BE KEPT SEPARATE. REFER TO ARCHITECTURAL PLANS FOR LOCATION OF FOUNDATION DRAINS AND DOWNSPOUTS. 13. STORM SEWER TO HAVE A 30" (2.5 FT) MINIMUM COVER OVER TOP OF PIPE. SITE NOTE NO EARTH DISTURBING ACTIVITY MAY COMMENCE WITHOUT AN APPROVED STORMWATER MANAGEMENT PERMIT. STORM SEWER NOTE THE ON -SITE STORM SEWER SYSTEM TO REMAIN PRIVATE. THE STORM SEWER SYSTEM SHALL BE CONSTRUCTED PER DESIGN SPECIFIED AND AS APPROVED BY THE CITY OF CARMEL ON THE FINAL APPROVED CONSTRUCTION PLANS. DEVIATIONS FROM THE APPROVED DESIGN SHALL ONLY BE PERMITTED DUE TO SPECIAL CIRCUMSTANCES OR DIFFICULTY DURING CONSTRUCTION AND WILL REQUIRE PRIOR FIELD APPROVAL FROM A DESIGNATED REPRESENTATIVE OF THE CITY OF CARMEL IN ADDITION TO SUPPLEMENTAL APPROVAL BY THE DESIGN ENGINEER. AN EXPLANATION OF ANY SUCH DEVIATION SHALL BE INCLUDED AS A REQUIREMENT ON AS-BUILT/RECORD DRAWINGS SUBMITTED FOR RELEASE OF PERFORMANCE GUARANTEES. APPROVED DESIGN SLOPES IDENTIFIED AS GENERATING VELOCITIES OF 2.5 FPS OR LESS OR 10 FPS OR GREATER (AT FULL FLOW CAPACITY) SHALL REQUIRE AS -BUILT CERTIFICATION AT THE TIME OF CONSTRUCTION, PRIOR TO BACKFILLING THE PIPE. THE CONTRACTOR IS INSTRUCTED TO AS -BUILT EACH SECTION OF STORM PIPE AS IT IS BEING INSTALLED TO ENSURE COMPLIANCE WITH THE DESIGN PLANS AND AS APPROVED BY THE CITY OF CARMEL. STR # TC/GUT* STRUCTURE TYPE CASTING TYPE INVERTS DOWNSTREAM PIPE INFORMATION DOWNSTREAM STRUCTURE DETAIL ON SHEET # 101 851.27+/- DOGOUSE MANHOLE NEENAH R-1772 N/S=841.27, E=841.30 EXISTING 21" RCP N/A N/A 102 845.50 POND OUTLET NEENAH R-4349-D W=841.30, E=841.30 267 LF OF 12" RCP @ 0.00% 101 C803 103 N/A EX. PIPE END N/A INV=841.40 N/A N/A N/A 104 848.90 AQUA -SWIRL AS3 BYP SEE DETAIL SE=844.05, NW=844.15 EX. 42 LF OF 12" RCP @ 6.30% 103 C803 105 848.52* INLET EXISTING SE=844.59, N=844.86, W=845.09 15 LF OF 12" RCP @ 2.95% 104 C803 106 849.15 INLET NEENAH R-3405 SE=845.49 50 LF OF 12" RCP @ 0.80% 105 C803 107 851.00 STANDARD MANHOLE NEENAH R-1772 S=845.34, N=845.44 108 LF OF 12" RCP @ 0.45% 105 C803 108 849.46* INLET NEENAH R-3405 S=845.76 99 LF OF 12" RCP @ 0.32% 107 C803 109 N/A PIPE END 24" FLAP GATE INV=841.40 N/A N/A C803 110 846.50 STANDARD MANHOLE NEENAH R-1772 SW=841.50, N=841.60 40 LF OF 18" RCP @ 0.23% 109 C803 111 844.40 EX. MANHOLE N/A N=841.80, S=841.80 88 LF OF 24" RCP @ 0.23% 110 C803 112 N/A END SECTION N/A INV=843.40 N/A N/A C802 113 851.70 STANDARD MANHOLE NEENAH R-1772 SW=843.48, N=843.58 40 LF OF 18" RCP @ 0.45% 112 C803 114 851.70 AQUA -SWIRL AS4 BYP SEE DETAIL S=843.82, N=843.92 55 LF OF 18" RCP @ 0.45% 113 C803 115 851.70 STANDARD MANHOLE NEENAH R-1772 S=843.97, N=844.07, W=845.17 10 LF OF 18" RCP @ 0.45% 114 C803 116 849.22 INLET NEENAH R-3405 S=844.48, W=844.58 94 LF OF 15" RCP @ 0.44% 115 C803 117 849.50 INLET NEENAH R-3405 E=845.40, W=845.50 126 LF OF 12" RCP @ 0.65% 116 C803 118 849.50 INLET NEENAH R-3405 E=845.82 100 LF OF 12" RCP @ 0.32% 117 C803 119 N/A PIPE END 12" FLAP GATE INV=842.78 N/A N/A C802 120 N/A END SECTION N/A INV=843.50 24 LF OF 12" RCP @ 3.00% 119 C802 1 r/1r\ 111 SAN s� EXISTING SANITARY SEWER & MANHOLE STM�� EXISTING STORM SEWER; INLET & M.H. PROPOSED STORM SEWER; INLET BEE HIVE INLET, M.H. AND END SECTION -710- EXISTING CONTOUR LINE 71o�J PROPOSED CONTOUR LINE PROPOSED TOP OF CURB/ 759.50 GUTTER GRADE 760.0o PROPOSED GRADE o----------- ROOF DRAIN WITH CLEANOUT DRAINAGE SWALE W/ UNDERDRAIN DRAINAGE FLOW ARROW MAIN CONSTRUCTION LIMITS OF LAND DISTURBANCE - - EMERGENCY OVERFLOW LIMITS 50° EMERGENCY INLET PONDING ELEVATION -�- EMERGENCY OVERFLOW DIRECTION FFE FINISH FLOOR ELEVATION MFPG MINIMUM FLOOD PROTECTION GRADE (CALCULATED TO BE 1 FT ABOVE THE ON -SITE EMERGENCY OVEFLOW ELEVATION OF 850.50 FT.) MLAG MINIMUM LOWEST ADJACENT GRADE IMMEDIATE TO THE BUILDING = 851.50 SITE FLOOD INFO THE SITE LIES ENTIRELY WITHIN THE FEDERALLY DESIGNATED FLOOD ZONE X (NOT A FLOOD HAZARD AREA) PER FLOOD INSURANCE RATE MAP (FIRM) #18057C 0209 G, EFFECTIVE NOVEMBER 19, 2014. TOPOGRAPHY NOTE THE EXISTING GROUND ELEVATIONS, IMPROVEMENTS AND LOCATIONS OF EXISTING UNDERGROUND UTILITIES SHOWN ON THIS PLAN ARE BASED UPON AN EXISTING CONDITIONS - DEMO PLAN PREPARED BY DEBOY LAND DEVELOPMENT SERVICES DATED OCTOBER 2, 2018. THE BOUNDARY INFORMATION SHOWN IS BASED UPON A LAND TITLE SURVEY PREPARED BY WEIHE ENGINEERS DATED APRIL 25, 1990. THE EXACT LOCATION OF EXISTING UNDERGROUND UTILITIES SHALL BE VERIFIED BY THE CONTRACTOR PRIOR TO ANY CONSTRUCTION. ROGER WARD ENGINEERING SHALL NOT BE HELD LIABLE FOR ANY ERRORS, INACCURACIES OR OMISSIONS RELATED TO THE ABOVE MENTIONED PLANS AND SURVEYS PREPARED BY OTHERS. BENCHMARK NOTE PROJECT BENCHMARK: HAMILTON COUNTY CGS DISK (STATION NAME: Y 42) SET IN A CONCRETE SLAB ON THE EAST SIDE OF THE MONON TRAIL 218 FT SOUTH OF 111TH STREET. ELEV.=838.62 (NAVD 88) • I � 1 Know what's below. PER INDIANA STATE LAW IS-69-1991. "all before you dig. IT IS AGAINST THE LAW TO EXCAVATE WITHOUT NOTIFYING THE UNDERGROUND LOCATION SERVICE TWO (2) WORKING DAYS BEFORE COMMENCING WORK. DRAINAGE SUMMARY TOTAL DRAINAGE AREA = +/-13.55 AC PROJECT LIMITS (DISTURBED AREA FOR THIS PHASE) = 2.93 AC 100-YR ALLOWABLE DISCHARGE FOR W.R. FERTIG WATERSHED = 0.25 CFS/AC = 3.39 CFS EXISTING CONDITION DETENTION POND RELEASE RATES 10-YR = 1.60 cfs (EX. 12" PIPE) @ ELEVATION = 842.94 100-YR = 3.02 cfs (EX. 12" PIPE) @ ELEVATION = 845.10 PROPOSED CONDITION DETENTION POND RELEASE RATES 10-YR = 2.01 cfs (EX. 12" PIPE) @ ELEVATION = 843.31 100-YR = 3.30 cfs (EX. 12" PIPE) @ ELEVATION = 845.50 VOLUME OF DETENTION REQUIRED IS 3.12 AC -FT VOLUME OF DETENTION PROVIDED IS 3.56 AC -FT z H Z z� J �--� Z O U W W CD ® Pyl � N rn z 1� _ � Q Q N O 0® X " U) zO oz Q a, �.� z U 0 J � w OJT bsl� ' � 0- I -I U) v z N z U') Q LO z W W z 0 z W U Z ^J I..L rw V z_ 0 W z 0 < Lr.Ln V Ui (/7 H H H Z W W UJ O U V U 0 WA N NwW N000 ZQ¢¢ O N N N (n C-4 > M w o 0 0 C-i rri � U-) J � Q W Z w O � � YQz w�zQ z �w�- a U U) w z ��� OOaQ •U Z Z Z LO W Ln No. PE19800489 STATE OF ��FSSN 1)1 /ONAL'\� BY: DATE: /06/20��] EETCl2 OF 19 JOB#: SCB.002