Loading...
HomeMy WebLinkAbout2nd Floor Plan1 Metal drip edge cone. trim board 44'_0" Stucco 2 x 6 Stud ws 16" o.c. 7/16" OSB sheeting — - R-13 batt insulation - 6 Mill poly vapor barrier 1/2" 10" Steel sill plate nchor @ 72" o.c. Grade IP 12" Poured concrete wall 30" V\/aterproof roofing with felt sub layer 7 TGI Ceiling joist @ 16' o.c. _ Dbl. 2 x 6 top plate 10'-0" TGI Floorjoist @ 16' o.c. 1/2" Sheetrock board walls and ceiling 10'-0" 2 x 6 cont. sill plate 4" Fiber -reinforced concrete floor L:8" x M' Conc. footing 5 96NI��12. S"fh1�-5 C Minimum R-38 blown in insulation First floor Black visqueen vapor barrier Minimum 4" pea gravel fill Note: Note: Slope grade from Verify soil conditions house a minimum of prior to constructing a 6" drop. foundation. 2 x 10 Cont. header - both sides — 10'-0" 30" Note: Column trim boards 4" Deck slab Rebar thickness and locations, as well as the basement wall sizes and the complete design of the foundation system is the responsibility of the foundation Contractor. These conceptual drawings, details, dimensions and notes are provided for reference only and need to be verified prior to construction whether for new or existing dwellings. All Contractors are required that their Copyright 2022, All rights reserved. materials, sizes, construction methods and No part of this publication may be reproduced labor forces meet all state, county and local or transmitted in any form or by any means, codes. These design requirements are to electronic or mechanical, including photocopying, take precedence over the project specifi- recording or by any information retrieval system cations and drawings - written or implied. without the permission of the copyright owner. Verify all dimensions rior p r to construction. Any unauthorized users will be prosecuted to the Contractors are responsible for the accuracies fullest extent of the law including any legal and correctness of these conceptual drawings fees incurred by the copyright owner. whether for new and/or existing construction. Wood column m 12" Concrete cont. footing � � a �xce PYT.� (D -tI `- t7 �S Cat' Q 2W r) F L OVfZ p . CC31 GNU Gill.., t lam\ cat 1i� 1(,,,,L•t = hC Ito-TE 5 MoI-C- t - - 4,'23 All design data, details and layoufs included and implied within the contents re the submitted drawings are are The Singh Residence p' Date:Dec. 12, '22 subject to vefi6fca the Builder/Owner. The drartsman will not be held liable based upon inaccurate and/orunk- G J nown vided ithinnorsonddions concept within these conceptual drawings. Eaton +Stipp Custom Horner Drawn b.: 1sso�eN AllRights88677 Bash Street Indianapolis, IN 46256 Scale: As noted