Loading...
HomeMy WebLinkAbout06100137 State Release " Would you like to reduce your turnaround time? ELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INDIANA AT efile24-7@dhs.state.in.us. Or VISIT OUR WEe SITE AT www.in.gov/dhs/osbc Project number E-Filed, No hard r" Release date I RUCTION DESIGN RELEASE 321372 copy will be mailed I 09/28/06 I 41191 (R9/5-98) I Construction type I Occupa~cy classification i ted on: September 28, 2006 V-B I ! M Scope of release I INDIANA 02 ARCH ELEC MECH d Security ~oo~,Qgoo_ PLUM I REVIEW 245 Type of release Standard Available At YOtJr Local Licence Branch Project name SUPPORT HOOSIER SAFETY The Mystery Company Street address 233 2nd Ave SW City I County I keelerwebb.com CARMEL HAMILTON CONST State Form Report Prin Indiana Department of Hometan DIVISION OF FIRE SAFETY / PLAN 402 W. Washington St., Room E Indianapolis, IN 46204 To: Owner I Architect I Engineer Keeler Webb Associates James P McCann 860332 486 Gradle Dr Carmie IN 46032 I I fax & e-mail: 3175741269. ghare@ "- The pians, specifications and application submitted for the above referenced project have been reviewed for compliance with the applicable rules of the Fire Prevention and Building Safety Commission. The project is released for construction subject to, but not necessarily limited to, the conditions listed below. THIS IS-NOT'A>BUILDING PERMIT-All required local permits and licenses must be obtained-prior to'beginningconstruction work. All construction work must be in full compliance with all applicable State rules. Any changes in the released plans and/or specifications must be filed with and released by this Office before any work is altered. This release may be suspended or revoked if it is determined to be issued in error, in violation of any rules of the Commission or if it is based on incorrect or insufficient information. This release shall expire by limitation, and become null and void, if the work authorized is not commenced within one (1) year from the above date. CONDITIONS: New Fees Schedule will be effective from September 30,2006 CLICK TO VIEW NEW RATES Note :(A 1A & A 1 B): In accordance with the affidavit sworn under penalties of pe~ury in the application for construction design release the plans and specifications filed in conjunction with this project shall comply with all of the applicable rules and laws of Fire Prevention and Building Safety Commission. Providing false;information constitutes an act of perjury, which is a Class D felony punishable by a prison term and a fine up to $10,000. In accordance with Section 19 of the General Administrative Rules (675 lAC 12-6-19) a complete set of plans and specifications that conform exactly to the design that was released by the office of the state building commissioner shall be maintained on the construction jobsite as well as a copy of the design release. 4G0412AF 3B0302B 3B 1 004G 3B1004E 3B100401 3B1004F 3B111.2 4G0411AA 3C0501A No addition, alteration, or repair shall reduce existing exit capacities to less than that required under the provisions of the rules of the Indiana Fire and Building Safety Commission for new construction in accordance with 675 lAC 12-4-12(d). The required fire barrier shall have a minimum fire-resistive construction as specified in Section 302.3.3 and Table 302.3.3, IBC (675 lAC 13-2.4). Fire-reslstance-rated corridors shall be continuous from the point of entry and shall not be interrupted by intervening rooms in accordance with Section 1004.3.2.5, IBC (675 lAC 13-2.4). Where more than one exit or exit access doorway is required, the exit access shall be arranged such that there are no dead ends in corridors more than 20 feet in length in accordance with Section 1004.3.2.3, IBC (675 lAC 13-2.4). Exit corridors shall be fire-resistance rated In accordance with Section 1004.3.2.1 and Table 1004.3.2.1, IBC (675 lAC 13-2.4). Corridors shall not serve as suppiy, return, exhaust, relief, or ventilation air ducts or plenums in accordance with Section 1004.3.2.4, IBC (675 lAC 13-2.4). Buildings shall be accessible to persons with disabilities in accordance with Section 1.2 (1 through 5) and (2), Part 1, Chapter 11, IBC (675 lAC 13-2.4). No change in the character or use of any building or structure shall be permitted which shall cause the building or structure to be c1assiifed within a different occupancy group or within a different division of the same occupancy group, unless such building or structure complies with or is made to comply with the current rules of the Indiana Fire Prevention and Building Safety Commission for new construction for the proposed revised use of the building in accordance with 675 lAC 12-4-11 (c). Buildings that are heated or mechanically cooled shall be constructed so as to provide the required thermal performance of the various componenis in accordance with Section 501.1, IECC (675 lAC Page 1/2 Would you like to reduce your turnaround time? ELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INDIANA AT efile24-7@dhs.state.in.us, Or VISIT OUR WEB SITE AT www.in.gov/dhs/osbc 19-3-1). 3B0602 Exterior walls shall have fire-resistance ratings in accordance with Table 602, IBC (675 lAC 13-2.4). 9P0412A Except in dwelling units, a fioor drain shall be installed in a toilet room containing two or more water closets or a combination of one water closet and one urinal in accordance with Section 412, IPC (675 lAC 16-1.3). 3B0715C Duct penetrations of fire barrier walls shall be protected by fire dampers in accordance with Section 715.5, IBC (675 lAC 13-2.4). Please be advised that if an administrative review of this action is desired, a written petition for review must be filed at the above address with the Fire Prevention and Building Safety Commission identifying the matter for which a review is sought no later than eighteen (18) days from the above- stated date, unless the eighteenth day falls on a Saturday, a Sunday, a legal holiday under State statute, or a day in which the Department of Fire and Building Services is closed during normal business hours. In the latter case, the filing deadline will be the first working day thereafter. If you choose to petition, and the before-mentioned procedures are followed, your petition for review will be granted, and an administrative proceeding will be conducted by an administrative law judge of the Fire Prevention and Building Safety Commission. If a petition for review is not filed, this Order will be final, and you must comply with its requirements. Filed By Code review official Code Enforcement & Plan Review Branch Director ERIK KASSIG v~d/S~ Address (~~!TI~~ti~le ~f 10c,:,1 offici~.I,street,city,state and ZIP code DEPT OF COMMUNITY SERVICE State Fire Marshal Vl~O~ JIM BLANCHARD 'ONE CIVIC SQUARE .CARMEL. IN 46032 Fax & e~mail: 3175712499,jblanchard@carmel.in.gov Page 2/2