Loading...
HomeMy WebLinkAbout06100090 Correspondence Page 1 of2 Nada Lawburg From: Nada Lawburg Sent: Monday, October 23, 2006 11 :40 AM To: 'JOchs@carmel.in.gov' Subject: RE: 06100090, 172 Parkview Ct, Carmel Attachments: Bubash Exhibit A.BMP; Bubash Exhibit B.BMP; Bubash Exhibit C.BMP; Bubash Exhibit D.BMP Jim, I have attached the plans that were submitted with the permit application. I will need to send more than one e-mail because of the size. r would like to make sure you received all the plans. I'm not sure what else you would need. r have also included a picture of the existing home (Exhibit K). Wall section to show; size and spacing of studs; shown on exhibit D, E, F (4x4's4'3" o.c. on 17' wall & 4' o.c. on 16' wall) size of headers; shown on exhibit C (2x8's) footer detail; shown on exhibit B (36" deep with 6" of concrete) floor construction detail;p shown on exhibit A (using existing slab) floor plan; shown on exhibit A ( ? ) method of attachement to house at top plate; shown on exhibit C (sistered to existing roof/wall ) spacing of roof rafters shown on exhibit C (16" on center) Please give me a call if! need to do anything furthur or if I need to bring additional copies to the office. JIIada~ Office Manager/Project Coordinator Mt. Carmel Construction 13295 Meridian Corners Blvd. #110 Carmel, Indiana 46032 317-844-7976 office 317-848-3469 fax RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes. DEPT OF COMMUNITY SERVICES CITY OF CARMEL / CLAY TOWNSHIP INDIANA From: Ochs, James A [mailto:JOchs@carmel.in.gov] Sent: Friday, October 20, 20064: 13 PM To: Nada Lawburg Subject: 06100090, 172 Parkview Ct, Carmel PERMIT PLAN REVIEW STOPS PAGE 1 10/30/2006 PERMIT NUMBER: PARCEL ID PARCEL ADDRS APPLY DATE CONTRACTOR PHONE NUNBER Page 2 of2' 06100090 - DAVE BUBASH 1709230406027000 172 PARKVIEW CT CARMEL, 10/12/06 ISSUE DATE MT CARMEL CONSTRUCTION (317) 844-7976 TYPE: RES PORCH IN 46032 C/O DATE FAX NUMBER (317) 848-3469 ------------------------------------------------------------------------------- REVIEW STOP: BLDG REV NO: 1 STATUS: REVIEW SENT BY: jochs REV RECEIVD BY: jochs REVIEW NOTES: - BUILDING INSPECTOR REVIEW D DATE: 10/20/06 DATE: 10/20/06 TIME: 16:08 DATE: 10/12/06 TIME: 16:08 CONT ID: TIME SPENT: SENT TO: 0.00 2006-10-20 16:11:41 Provide the following: Wall section to show; size and spacing of studs; size of headers; footer detail; floor construction detail;p floor plan; method of attachement to house at top plate; spacing of roof rafters James Ochs, C,B.C, Building Inspector/Plan Review 10/30/2006 ...-:-- ...)o..~, --;!: ho.J. .e-~~\~ ~ ~\\oV-'~O \,,~ ~-\- ~ 'b '--'~ -X '-'0. ~ AO+- ~rcIi a..1\A.I'\-\"}e}' ~-e..tl. ~ -\= c-""--'~o- ~ ,-^->'. ~ Cl.""-{ ~ ~S-'.., "'-'- ~ . ~o.."'V\L'10'--' I ?l~ /--e::r