Loading...
HomeMy WebLinkAboutROOF PLAN-Plot℄℄42'-4"121110987654322.32.8HCDEFGG.1G.9G.5F.4F.8D.8E.7HB141411.12.52.93.33.84.44.313AA.1A.9B.9B.5B11.92.1GENERAL NOTES1.FLASH ALL PENETRATIONS AND ROOF EDGES (SKYLIGHTS, CURBS, ROOF DRAIN, VENT PIPES, ETC.) @ SINGLE PLY ROOFING INACCORDING W/MFR AND NRCA INSTRUCTIONS. PROVIDE STEEL ANGLE FRAME AROUND ALL DECK OPENINGS GREATERTHEN 1'-0".2.G.C. TO COORDINATE ALL EQUIPMENT FRAMING & ROOF PENETRATIONS WITH ALL DISCIPLINES.3.SEE PLUMBING AND CIVIL DRAWINGS FOR ADDITIONAL INFORMATION @ ROOF DRAIN CONNECTION (TYP).4.O.D. SHALL BE MINIMUM 8" ABOVE R.D. (TYP).5.ANY INTAKE GRILL SHOULD NOT FACE TO REFRIG./EXAUST FANS (TYP).6.DESIGN INTENT IS FOR EXTERIOR DOWNSPOUTS AND ASSOCIATED SCUPPERS (KEYNOTE 7) TO BE HORIZONTALLY CENTEREDWITHIN THE WIDTH OF A PRECAST PANEL. COORDINATE WITH PRECAST CONTRACTOR TO ESTABLISH FINAL DIMENSIONS.7.DESIGN INTENT IS FOR OVERFLOW SCUPPERS (KEYNOTE 13) TO BE HORIZONTALLY CENTERED WITHIN THE WIDTH OF APRECAST PANEL. COORDINATE WITH PRECAST CONTRACTOR TO ESTABLISH FINAL DIMENSIONS. COORDINATE FINALDIMENSIONS WITH PLUMBING CONTRACTOR TO ALLOW FOR ALIGNMENT OF ASSOCIATED ROOF DRAIN LEADERS.KEYED NOTESNODESCRIPTIONNODESCRIPTION1MEMBRANE ROOFING SYSTEM MECHANICALLY FASTENED OVER RIGID INSULATION(TYP). PROVIDE INSULATION TO MEET OR EXCEED THE R-VALUE INDICATED IN THEENVELOPE COMPLIANCE CERTIFICATE.13WHERE THE MAIN ROOF CRICKET SLOPES INTERACT WITH ROOFTOP EQUIPMENT,CURBS, SKYLIGHTS, ETC. G.C. TO PROVIDE DEFLECTORS SO AS TO ENSURE POSITIVEDRAINAGE THROUGHOUT THE ENTIRE ROOF (TYP).2ROOF HATCH. PROVIDE TAPERED INSULATION CRICKET AS REQUIRED. REFER TODETAIL 12/A800. SEE SPECIFICATIONS FOR TYPE.14BRONZE COW TONGUE (GROUND LEVEL). INSTALL A MINIMUM OF 1'-0" ABOVESURFACE OF SIDEWALK (TYP).3SKYLIGHT (TYP). PROVIDE TAPERED INSULATION CRICKET AS REQUIRED. REFER TODETAIL9/A800. COORDINATE W/ COMCHECK ENVELOPE COMPLIANCE CERTIFICATETO DETERMINE TYPE. SEE SPECS FOR TYPES.15REFRIGERATION CONDENSER LINE CURB. REFER TO ENLARGED DETAIL 2/A800 &MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION (TYP. @ EACH CONDENSERRACK).4INSTALL TAPERED INSULATION CRICKET, AS REQUIRED, FOR POSITIVE DRAINING.MINIMUM 1/2" PER FOOT (TYP).16MECHANICAL ROOM AIR INTAKE. SEE MECHANICAL DRAWINGS FOR ADDITIONALINFORMATION.5ROOF DRAIN (TYP). REFER TO PLUMBING AND CIVIL DRAWINGS.17EXHAUST VENT (TYP). REFER TO MECHANICAL DRAWINGS.6OVERFLOW ROOF DRAIN. REFER TO PLUMBING & CIVIL DRAWINGS.18ENGINEERED METAL CANOPY. REFER TO DETAIL 1/A701 & STRUCTURAL DRAWINGS.7PRE-FINISHED METAL DOWNSPOUT AND SCUPPER (TYP). REFER TO DETAIL 5/A800.19FOR ROOF MOUNTED GAS LINES REFER TO PLUMBING DRAWINGS.8CONDENSING UNIT REFRIGERATION LINES CURB. REFER TO ENLARGED DETAIL15/A800 & MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION (TYP. OF 6).20OVERFLOW SCUPPER (TYP.) @ REAR OF BUILDING. REFER TO DETAIL 5/A800.9ROOF MOUNTED REFRIGERATION CONDENSERS. REFER TO RE DRAWINGS.21OVERFLOW SCUPPER (TYP.) @ FRONT OF BUILDING. REFER TO DETAIL 11/A800.10WALKWAY PAD PATHWAY (TYP). REFER TO ROOFING SPECIFICATION.22ENGINEERED METAL CANOPY. REFER TO DETAIL 2/A704 & STRUCTURAL DRAWINGS.11ROOF VENT/FLU (TYP). REFER TO DETAILS 7/A800 & 10/A800 RESPECTIVELY ANDPLUMBING/MECHANICAL DRAWINGS.23MECHANICAL EQUIPMENT ROOF SCREENING. REFER TO MECHANICAL DRAWINGS.12SPLIT SYSTEM HVAC (TYP). REFER TO MECHANICAL DRAWINGS.SCALE:1A300ROOF PLAN1/16" = 1'-0"NORTHNOTE LEGENDKEYNOTEBOLLARDDOOR NUMBERROOM NAMEEQUIPMENT ITEMWINDOW NUMBERPARTITION TYPE##XROOMNAME#######11334991016A8009A800SLOPED ROOF. 1/4" PER 1'-0" (TYP.)SLOPED ROOF. 1/4" PER 1'-0" (TYP.)7℄℄℄℄℄℄44'-0"18'-8"℄℄2'-0"14A80012A80015A800TYP.111111518101288131617191515204A70521717A9021A7021A7033A700TYP.1A700TYP.1A700SIM1A700SIM1A700SIM2A704SIM1A70140'-0"44'-8"℄29'-4"℄64'-0"℄52'-0"℄46'-8"℄29'-4"℄39'-5 1/2"℄45'-2 1/2"37'-6"℄37'-6"℄37'-6"℄37'-3"℄19'-7"℄37'-6"℄37'-6"℄37'-6"℄37'-3"℄19'-7"℄37'-6"℄18'-8"℄18'-10"℄18'-8"℄18'-10"℄18'-8"℄18'-10"℄18'-8"℄18'-10"℄18'-8"℄18'-10"℄18'-5"℄18'-8"℄10'-5"℄26'-7"℄37'-6"℄37'-6"℄37'-6"℄37'-6"℄37'-1"℄℄18'-8"℄18'-8"℄18'-10"℄18'-8"℄18'-10"℄18'-8"℄18'-10"℄18'-5"℄18'-8"℄10'-5"℄37'-6"℄37'-6"℄37'-6"℄37'-1"℄℄8'-4"2'-0"27'-10"℄24'-9"℄22'-3"℄22'-10"℄22'-10"℄22'-10"℄23'-10"℄24'-1"℄30'-9"℄8'-4"℄42'-0"41'-6"42'-0"1A70042'-0"48'-1"℄51'-3"℄25'-2"10101010101010191111111111111744121220521521521521521521565617171919191919433℄2'-0"6℄1119101910191019191942'-2"2A700TYP. @ DOOR℄521222222222222221123171414121A704131313Project NumberDrawn By/Checked By:CONSTR. DOC. & REVISIONS No.Description Date BJ'S WHOLESALE CLUB #228 14490 LOWES WAY, CARMEL, IN 46033 210093907/20/23WHOLESALE CLUB12 Sunnen Drive, Suite 100, St. Louis, MO 63143 T: 314.821.1100Owner DatePermitTBDBidTBDMARCIA A. SIEMERLicense NO. AR12300004Expiration Date 12/31/23PROFESSIONAL OF RECORDFOR OWNER REVIEW ONLY.N O T F O R B I D , P E RM I T O RCONSTRUCTION.A300ROOF PLANDRB/KWH--- --- --- --- --- --- --- --- ----