HomeMy WebLinkAbout06100209 Site Plan
'-~
Schn8ider
the &:lm.eLde.r CorponUon
8i01 otIJ A......
IIIItorloF",_
""'M....p"'K~. Indiana 46218-1037
317-828-7100
317-828-7200 FAX
~
I!umllq
LuidJcape Arc:!Iltecturo
G!3.lllI
GeaIDc'
This Plot Plan Prepared For: Arbor Homes
Lot # 38 ,containing 12,599 S.F.:!:, in
The Trails at Hayden Run Sec. 1
INSTR. # 200500069468
Clay Twp, Hamilton County
Sec 20, T29N, R3E
3222 FERRELL DRIVE
Westfield, IN 46074
Prepared Date: 10/26/06: By: KAG
(50'R/W)
Community Restrictions:
Sid. Yard -3' min.
Rear Yard = H/A
Aggre<Jat. = 6 (B.H.)
ARBOR HO~ES
Pad Grade = 920.2 per plan
Pad Grad. + 1.0' = Garage m: (921.2)
Garag. m: + 0.5' . Residential m: (921.7 )
Resldenti~ m: - 9.0 ' = Basement m: (912.7 )
Driveway Slap. = 4.B:;
Nat. : Th. garage f"lstI.d floor eie'lOllan
Is 1.9' aba", the curb at the drl"" per
plan.
GROUND COVER CALCULATIONS:
Dri", = 930 SH
Public Walk = 370 SF t
Privote Walk = 76 SFt
Seeding = 6,521SFt
Sad = 2,910 Sft ,
even with the rear of house.
".H.1802
TC=919.4.\
PER REC. D\\\;.
flOOD HAZARD STATEMENT
CERllFlCA 1l0N
,\\\1\\1\1\\11111/1/1/",//,
#\'\ c. L. cJ~
~ ~'\~ .......... '7"h)%,
~~~""G"\5 Te4';;:.,,, A~
~ ...... N ""^' ",...,.~
~ oC:::::) "Q:o"V 0 V ", ;<>~
, (' S0303.....) \
s ~ ! ~
% ", STATE OF ..' fff
~ /.... .... ~
~ (A ....Ilvol At.\!:'.... ~~
~ 741; .............. C\ '> ~
~" SUR~ '-~\#
r;////fl/IIIIIII\I\\I\I\\\\~
~lfti
Plat Plan Legend
~ Proposed Grades
000.0 Existing Grades
-000.0-- Contour Grade
* Appra~ Lateral Locotlan
- . - Sanitary Sewer Unes
-IT- Storm Sewer Unes
- I,f - Water ServIce Lines
- - - - - - - Sub-Surface Drain Unes
. ~anh~s (Sanitary ar Storm)
. B.eIll" Inl,t (Storm)
IlIII Curb Inlet (Slanm)
D End Sectlan (Storm)
..... Fire Hydrant
- 000 - 000 -Flaw Une of swale
Hote: Sanitary Sew"
Tap of Casting Informatlan
Upstream Manhole. TC= 919.45
Downstream ~anhole. TC=919.38
per record drawing.
Note:
The contractor Is to maintain a
minimum dl.lance 01 len feel (10')
between the sanltry sewer and water
lineloterals.
36.93'
'"
0;
0;
---
---
.2'
--
--
,
,
I
,
I
,
I
,
I
,
67.T
--,
a
a
c:i
...
-
Nate:
This drawing is based on construction plans or record drawings,
and Is nol based upan a fl~d survey. The Schneider Corporatlan
does not warrant the accuracy or sufficiency of this lnformatlon.
Contractors should verify existing conditions prior to any
construcUan. MY discrepancy found an this drawing should
be reported to The Schneider Corporation immediately. failing
to do SO results In the controctors assumption of all Iiabnlty.
Note:
The basement elevation, depleted hereon, has been determined and
based on the pod grades ond/rK contours takll1 from the constnJctlon
plans frK this subdMslon. Unless stated. no Infcnnotlon obotlt f1uctuotlng
water tables, soli conditions, rK soU t)1les has been provided or" stated
on sold plons. this lot Is located near a body of water. Lot or sol
conditions may requn that the bosement floor e1ewtlon be held 2 foot
000.." norma pool e1e'lOtIon. SIte Investlgatkwl may be needed If water Is
lI1countnd du.rIn9 the IXCQwtIcn pr1)teSS f:1 If other known 'll'ater
elevation or soUl conditions OI'e present. In_ligation and ooy remedial
procedurN III at the discretion of the buldel' to determine CIld itcke
appropriate steps of oct/on. If any ground water Is encounteredcdurtng
exC<lwtlon the buOd... Is enCOtlraged to contact The Schneid...
CoI'poratlon to discuss poaslble courses of action.
NOTE:
SU~P PU~p(S) TO BE PLACED
BY BUILDER AS NEEDED.
LOT # 38
VB # 06.0063452
ij
~
=li01=
Detan of t)1llcal Storm
Water flow pattern for
Individual lots.
-
It/I :
I I
I I
.....
ij
Assumed Harth
Scole : 1. = 30'
V. C.A. i J Note: Sunder to en,sure
~I/. D'U.4<SSf positi'" drainage away
1.f.A.f4<i>i;; 4< from structure(s).
POND . .c.<.
Np 12
100'ri?~ 915.00
~ 917.78
90.00'
15' D.E
w
0;
0;
---
---
GIm
66.T
---
,
I
I
I
I
I
/lfCi( I
I '0
I
29.00 , a
c:i
SIJ ... SCiJ ::
I:? PUMP Is
;( ;f '"
d
10.0' i;I
.
5' WAlX
---
----
----
PER5~
_ tir",9.J
----.:.: PlAN
-~------- ~ {E~~~~~__~RIVE
=====-- ~ ----------
===-- ~ -----
VAI/ C.A'12 ===-- ~~~. ~
. D,U.4<S ~ I
LI.f.A.f4<i> S.f 4< ..' E
POND .I.ff ~ .
N.p.~ 91f T'lPICAl OWAll' SEC110N
ICOYl/_ .40 Nate: \
This drowing Is not intended to be represented as a retrocement or - 917.64 Per Canm.1 zoning ardlnan" 26.1.1 : Th. residential
original boundary survey. a route survey, or a Surveyor Location Report. district limits height to twenty-RYe" feElt (25'), how~ver
a dw~ling may b. Increased In h.lght to thlrty-fl",
fest (35') pravlded th, slds and rear yards are incr",sed
an addltlan~ an. foat (1') for each ane foat (,') the
structure exceeds the frst twenty-fl", feet (25') In
height.
-
'IE
---
---
-..._-
Flood Hazard Statement: The occurocy of any flood hazard data shown on this report
Is subject to map SCGle uncertainty and to any other uncertanty nlocotlon or
~'''lIan an the referenced flood it""""" rat. mop. ALL of the wlthit deealbed land
DD€S HOT UE wlthit that opecld flood hazard zone A as oald land plats by scaI. an
flood it..rance rate mop # 18057C0205F far CIty of Carm~, Indiana (maps dated
February 19, 2003).
--
".H.f801
TC=919.38
PER RE~ D\\\;.