Loading...
HomeMy WebLinkAbout06020094 Correspondence Au~ 14 06 02:57p HRQuest 317-581-8856 p.1 Richard O. Albright, P. E. Consulting Eri9ineer 430 North Rangeline Road (46032) POBox742 Cannel, lndiana46032-0742 317-581-8877 317-581-8856 Fax raIxite1ijndy.net August 14,2006 Mr. Chris Thomas Drees Homes, Inc. 6650 Telecom Drive, Suite 200 Indianapolis, IN 46278-6278 Re: Ledger angles, Lot 29, Lakeside Dear Mr. Thomas: As you requested, 1 inspected the steel angles supporting the brick veneer on this new home. The brick veneer on the front of the home is corbelled about 2 to 2 Y, inches, and this exceeds the residential code. The single-story section in front is about 12 Yz feet across, and there is a double window in the wall about 6 Yz feet wide. To support the veneer, 3-inch steel angles have been bolted to the concrete angles Willi expansion anchors about 1 Yz feet apart. The horizontal legs of the angles were trimmed to match the face of the bricks. Ths combination of steel angles and anchors will support the bricks with an ample factor of safety. Please let me know if ~ou have any questions. Richard 0 Albright Professional Engineer .,.;~\)'O~"AjB;;~'" /...$,>~-;;C;;T"ieJ" ~"" l'Ji.['<-"- -'- ~o "'\ g No. 7f59 i : ~ ! STATE OF :: \10;" .I _..-~--' ':- If-./ ....~:~JyOUl..t-1 ..~... '. SS,.--..--;:-..[.:> ." .......OIlAl ~'...... .' J0rVli f/- ;V; . clt( ~ ~ ~ V~l \ V) Richard 0 Albrigllt, Inc.