HomeMy WebLinkAboutC800 UTILITY PLANS - ROSIES GARDENSSTORM SEWER STRUCTURE DATA TABLE
STRUCTURE
NUMBER
100
101
102
200
200A
201
202
203
204
210
220
230
240
250
300
301
TOP OF
CASTING
836.08
842.25
839.85
842.83
843.18
843.44
844.15
844.95
843.65
844.14
845.35
844.19
845.35
845.70
840.22
843.22
STRUCTURE
TYPE
NULL STRUCTURE
OUTLET CONTROL STRUCTURE, BOX
FLARED END SECTION
PAVED INLET, ROUND STRUCTURE, ROUND CASTING
PROPOSED MANHOLE
PAVED INLET, ROUND STRUCTURE, ROUND CASTING
PAVED INLET, ROUND STRUCTURE, ROUND CASTING
BEEHIVE INLET, ROUND STRUCTURE
FLARED END SECTION
PAVED INLET, ROUND STRUCTURE, ROUND CASTING
PROPOSED MANHOLE
PAVED INLET, ROUND STRUCTURE, ROUND CASTING
NYLOPLAST, AREA INLET
NYLOPLAST, AREA INLET
FLARED END SECTION
WATER QUALITY STRUCTURE, ROUND
CASTING TYPE
N/A
SEE DETAIL
N/A
R-3405
R-1772
R-3405
R-3405
R-4342
N/A
R-3405
R-1772
R-3405
STANDARD GRATE, H20
STANDARD GRATE, H20
N/A
PER MANUFACTURER
INVERT
INV OUT (SE)= 835.95 (24" HDPE)
INV IN (N)= 838.23 (18" HDPE)
INV IN (W)= 838.83 (18" HDPE)
INV IN (N)= 839.00 (15" HDPE)
INV OUT (S)= 838.73 (18" HDPE)
INV IN (N)= 838.50 (18" HDPE)
INV OUT (S)= 839.85 (18" HDPE)
INV OUT (W)= 838.40 (18" HDPE)
INV IN (W)= 839.69 (15" HDPE)
INV OUT (E)= 839.44 (18" HDPE)
INV IN (SW)= 840.65 (12" HDPE)
INV IN (N)= 840.50 (8" HDPE)
INV OUT (E)= 840.40 (15" HDPE)
INV IN (W)= 842.80 (12" HDPE)
INV OUT (NE)= 841.73 (12" HDPE)
INV OUT (E)= 842.95 (12" HDPE)
INV IN (N)= 840.15 (12" HDPE)
INV OUT (S)= 840.05 (15" HDPE)
INV IN (N)= 840.59 (12" HDPE)
INV IN (W)= 841.40 (8" HDPE)
INV OUT (S)= 840.49 (12" HDPE)
INV OUT (S)= 840.75 (12" HDPE)
INV IN (W)= 842.20 (8" HDPE)
INV OUT (E)= 842.10 (8" HDPE)
INV OUT (E)= 842.90 (8" HDPE)
INV IN (N)= 838.23 (18" HDPE)
INV IN (E)= 838.35 (18" HDPE)
INV OUT (S)= 838.35 (18" HDPE)
INV OUT (S)= 842.28 (8" HDPE)
PROPOSED STORE BLDG.
50' X 100'N. COLLEGE AVE(PUBLIC ROW)VILLAGE PLACE S.
(PUBLIC ROW)
VACATED 25' ROW PER
BOOK 87 PAGE 100 AT HCSO
OHU OHU OHU OHU OHU OHU
LOT 29
LOT 30
LOT 31
LOT 32
LOT 33
LOT 34
LOT 35
LOT 36
LOT 93
LOT 94
LOT 95
LOT 96
LOT 97
LOT 101
LOT 100
LOT 99
LOT 98
OHU OHU OHU OHU
WWWWWWWWWWWWWWWWOHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHUOHUOHUOHUOHUOHUOHUOHUOHUOHUOHUOHUOHUOHUOHUOHUOHUOHUOHUOHUOHUOHUE E E E E E E
FFE = 845.90
FFE = 845.65
FFE = 846.00
MLAG = 846.00
MFPG = 845.35 DDDDDDDDDDDDDDDDDDDDDDD
D
D
D
D
D
DDD D D D D D D D D
D DDDDDDDDDDDDDDDDDDDDDDWWWWWWWW W W W W WW
W
WE
EEEEE10
14
10
4
1066
66 7
STM GGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGWWWWWWEEEEEEEW1
NOTE:
THIS PORTION OF WATER MAIN
NOT FIELD LOCATED
SS1
SS2
SS3 SS4
W2
W3
W4
E1
E2
G1
G2
G1
G2
E2
W4
STORM SEWER PIPE DATA TABLE
UPSTREAM
STRUCTURE
101
200
200A
200A
201
202
203
204
210
220
230
240
250
301
DOWNSTREAM
STRUCTURE
200A
301
102
200
201
202
203
200
210
220
220
240
300
SIZE
24"
18"
18"
18"
18"
15"
12"
12"
15"
12"
12"
8"
8"
18"
MATERIAL
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
HDPE
LENGTH
77'
11'
10'
25'
202'
141'
98'
7'
132'
97'
47'
111'
109'
25'
SLOPE
0.32%
2.07%
0.50%
6.57%
0.30%
0.50%
1.11%
2.12%
0.79%
0.35%
0.35%
0.63%
0.64%
0.50%
UTILITY PLAN NOTES
SANITARY SEWER NOTES
CONNECT PROPOSED 6" SANITARY SEWER LATERAL TO EXISTING
SANITARY SEWER LATERAL. COORDINATE CONNECTION WITH MEP.
PROVIDE CLEANOUTS AS REQUIRED/SHOWN. VERIFY INVERTS ON
EXISTING LINE AND COORDINATE CONDITIONS WITH MEP. ADJUST AS
REQUIRED.
EXISTING 15" SANITARY SEWER.
PROPOSED SANITARY LATERAL CLEANOUT TYPE 2 (IN PAVED AREAS
OUTSIDE OF 3' OF BUILDING). REFER TO DETAIL ON SHEET C801.
PROVIDE 18" MINIMUM VERTICAL CLEARANCE BETWEEN
SANITARY/WATER/STORM SEWER PIPES AND ALL OTHER PIPES.
INSTALL CONCRETE CRADLE IF CLEARANCE IS LESS THAN 18"
EXISTING SANITARY LATERALS SHOWN ARE APPROXIMATE.
LOCATIONS ARE PER RECORD DRAWINGS. CONTRACTOR SHALL
FIELD VERIFY LOCATION AND DEPTH OF LATERAL PRIOR TO
CONSTRUCTION. NOTIFY OWNER AND ENGINEER OF POTENTIAL
CONFLICTS.
WATER SERVICE NOTES:
EXISTING FIRE HYDRANT. COORDINATE FIRE HYDRANT RELOCATION
WITH COLLEGE AVE IMPROVEMENTS
EXISTING WATER METER
COORDINATE AND CONNECT 2" WATER SERVICE LINE TO EXISTING
WATER METER
COORDINATE CONNECTION OF DOMESTIC SERVICE LINE WITH
PLUMBING DRAWINGS.
COORDINATE LOCATION AND CONNECTION OF DOMESTIC METER
WITH LOCAL SERVICE PROVIDER.
PROPOSED 3 4" WATER METER FOR IRRIGATION
ELECTRIC NOTES:
COORDINATE AND CONNECT BUILDING ELECTRICAL LINE FROM
SERVICE DROP LOCATION TO TRANSFORMER. COORDINATE
CONNECTION WITH POWER COMPANY AND ELECTRICAL
DRAWINGS. ADJUST AS REQUIRED.
BUILDING ELECTRICAL LINE POINT OF CONNECTION. COORDINATE
CONNECTION WITH POWER COMPANY AND ELECTRICAL DRAWINGS.
ADJUST AS REQUIRED.
COMMUNICATION NOTES:
COORDINATE AND CONNECT BUILDING COMMUNICATION SERVICE
LINE(S) TO CONNECTION POINT AS SHOWN. ADJUST AS REQUIRED.
[4"] PVC CONDUIT TO BE INSTALLED WITH PULL STRINGS.
CONTRACTOR TO PROVIDE.
COORDINATE CONNECTION WITH SITE DRAWINGS AND SERVICE
PROVIDER FOR RELOCATION OF PEDESTAL.
GAS SERVICE NOTES:
CONNECT PROPOSED GAS SERVICE TO EXISTING GAS LINE. REFER
TO PLUMBING DRAWINGS AND COORDINATE WITH SERVICE
PROVIDER.
COORDINATE PROPOSED GAS SERVICE LOCATION WITH SERVICE
PROVIDER.
RIGHT OF WAY LINE
BOUNDARY LINE
ROW RIGHT OF WAY
ESMT EASEMENT
D.&U.E.DRAINAGE AND UTILITY EASEMENT
FFE FINISH FLOOR ELEVATION
RCP REINFORCED CONCRETE PIPE
PVC POLYVINYL CHLORIDE PIPE
HDPE HIGH DENSITY POLYETHYLENE PIPE
SSD SUB SURFACE DRAIN PIPE
STM STORM
SAN SANITARY
STR STRUCTURE
CO CLEANOUT
PAVEMENT
UTILITY PLAN LEGEND
UTILITIES
ABBREVIATIONS
LINE TYPES
EXISTING SANITARY SEWER MAIN
EXISTING STORM SEWER MAIN
UNDERGROUND GAS
UNDERGROUND WATER
UNDERGROUND ELECTRIC
UNDERGROUND COMMUNICATIONS
OVERHEAD UTILITY
G G
W W
E E
C C
OHU OHU
SANITARY SEWER LATERALSANSAN C800 UTILITY PLAN - ROSIES GARDENSC800UTILITY PLANW22.0156SSRW22.015604/06/2023EACSSRROSIE'S GARDENS10402 N. College Avenue, Carmel, IN 46280SS1
SS2
SS3
SS4
W1
W2
W3
W4
W5
W6
E1
E2
C1
G1
G2
C2
10 9abcd 8 7 6efgh109876
5 4 3 2 Part of the NE/4 of Section 11, Township 17 North, Range 3 East, Clay Township, Hamilton County, Indiana1 PREPARED FOR:PROJECT NO.
SHEET NO.abcd5 4 3 2
e1
fhAPPROVAL PENDINGNOT FOR CONSTRUCTIONREVISIONS PER SECOND ROUND OF COMMENTS 08.21.2023SMB1gALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild with confidence.SMENGINEERS317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546 faxWEIHELand Surveying | Civil EngineeringLandscape ArchitecturePROJECT NO.:REVISIONS AND ISSUESDATEBYDWG NAME:DESIGNED BY:DRAWN BY:CHECKED BY:DATE:W
S
N
E
Know what's below.
before you dig.Call
R
STEVEN SCOTT RUCKER P.E. 11300279
HEAVY DUTY ASPHALT
CONCRETE PAVEMENT
STANDARD DUTY ASPHALT
GUY ANCHOR
ORNAMENTAL LIGHT
STREET LIGHT
ELECTRIC OUTLET
UTILITY POLE
UTILITY POLE W/ TRANSFORMER
COMMUNICATIONS JUNCTION BOX
COMMUNICATIONS PEDESTAL
FIRE HYDRANT
SPRINKLER CONTROL VALVE
SPIGOT
WATER METER
GAS METER
ELECTRIC METER
EXISTING BOLLARD
POST
ACCESSIBLE SPACE
COMMUNICATIONS RISER
EXISTING BEEHIVE INLET
EXISTING ROUND INLET
EXISTING SQUARE INLET
EXISTING SANITARY SEWER MANHOLE
PARKING LOT LIGHT (1 HEAD)
PARKING LOT LIGHT (2 HEAD)
OTHER
PROPOSED BOLLARD
PROPOSED END SECTION
PROPOSED STORM INLET
PROPOSED STORM INLET
BOARD FENCE
CHAINLINK FENCE
PROPOSED STORM SEWER MAIN
LIMITS OF DISTURBANCEDD
NOTE
COLLEGE AVENUE IS SHOWN BASED
ON FUTURE PLANS BY CARMEL
SS5
NOTE
EXISTING SANITARY LATERALS HAVE
NOT BEEN LOCATED BY SURVEY.
RECORD DRAWINGS INDICATE THE
LOCATIONS SHOWN. IF AN EXISTING
SHARED LATERAL IS FOUND IT MUST
BE SEPARATED PRIOR TO
CONNECTION OF NEW SERVICE.