Loading...
HomeMy WebLinkAboutSpec Sheet 22kw 27kw 32kw 38kw.pdf1 of 9 ® INCLUDES:  Two-Line LCD Multilingual Digital Evolution™ Controller (English/Spanish/French/Portuguese) with external viewing window for easy indication of generator status and breaker position.  True Power™ Electrical Technology  Isochronous Electronic Governor  Sound Attenuated Enclosure  Closed Coolant Recovery System  Smart Battery Charger  UV/Ozone Resistant Hoses  ±1% Voltage Regulation  Natural Gas or LP Operation  5 Year Limited Warranty  UL 2200 Listed  SwRi® listed (NFPA37, clause 4.1.4.1.2) Generator can be installed a minimum 18 in distance from combustible wall* Protector® QS Series Standby Power Rating Model RG022 (Aluminum - Bisque) - 22 kW 60 Hz Model RG027 (Aluminum - Bisque) - 27 kW 60 Hz Model RG032 (Aluminum - Bisque) - 32 kW 60 Hz Model RG038 (Aluminum - Bisque) - 38 kW 60 Hz Protector® QS Series Meets EPA Emission Regulations 22 & 27 kW are CA/MA emissions compliant 32 & 38 kW not for sale in CA / MA FEATURES  INNOVATIVE DESIGN & PROTOTYPE TESTING are key components of GENERAC’S success in “IMPROVING POWER BY DESIGN.” But it doesn’t stop there. Total commitment to component testing, reliability testing, environmental testing, destruction and life testing, plus testing to applicable CSA, NEMA, EGSA, and other standards, allows you to choose GENERAC POWER SYSTEMS with the confidence that these systems will provide superior performance.  SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION. This state-of-the-art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge loads to the engine. Digital voltage regulation at ±1%.  TEST CRITERIA:  PROTOTYPE TESTED  NEMA MG1-22 EVALUATION  SYSTEM TORSIONAL TESTED  MOTOR STARTING ABILITY  SINGLE SOURCE SERVICE RESPONSE from Generac’s extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component.  MOBILE LINK® CONNECTIVITY: FREE with all Protector Series Home standby generators, Mobile Link Wi-Fi allows users to monitor generator status from anywhere in the world using a smartphone, tablet, or PC. Easily access information such as the current operating status and maintenance alerts. Users can connect an account to an authorized service dealer for fast, friendly, and proactive service. With Mobile Link, users are taken care of before the next power outage. 2 of 9 ® 22 • 27 • 32 • 38 application & engineering data ENGINE SPECIFICATIONS: 22, 27, 32 & 38 kW Make Generac Model In-line Cylinders 4 Displacement (Liters) 2.4 Bore (in/mm) 3.41 / 86.5 Stroke (in/mm) 3.94 / 100 Compression Ratio 9.5:1 Intake Air System Naturally Aspirated (22 & 27 kW) or Turbocharged / Aftercooled (32 & 38 kW) Lifter Type Hydraulic ENGINE LUBRICATION SYSTEM Oil Pump Type Gear Oil Filter Type Full flow spin-on cartridge Crankcase Capacity (qt/l) 4 / 3.8 (22, 27, 32 & 38 kW) ENGINE COOLING SYSTEM Type Closed Water Pump Belt driven Fan Speed (rpm) 1,980 - 22 & 27 kW 1,500 - 32 & 38 kW Fan Diameter (in/mm) 18.1 / 459.7 (22 & 27 kW) or 22 / 558.8 (32 & 38 kW) Fan Mode Pusher (22 & 27 kW) or Puller (32 & 38 kW) FUEL SYSTEM Fuel Type Natural gas, propane vapor Carburetor Down Draft Secondary Fuel Regulator Standard Fuel Shut Off Solenoid Standard LP Fuel Pressure 5 – 14 in Water Column NG Fuel Pressure 5 – 14 in Water Column ENCLOSURE FEATURES Aluminum weather protective enclosure Ensures protection against mother nature. Electrostatically applied textured epoxy paint for added durability. Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries. Small, compact, attractive Makes for an easy, eye appealing installa- tion. SAE Sound attenuated enclosure ensures quiet operation. GENERATOR FEATURES Revolving field heavy duty generator Directly connected to the engine Operating temperature rise 120 °C above a 40 °C ambient Class H insulation is NEMA rated Class F insulation is NEMA rated All models fully prototyped tested ELECTRICAL SYSTEM 3 of 9 ® GENERATOR OUTPUT VOLTAGE/kW - 60 Hz kW LPG Amp LPG kW Nat. Gas Amp Nat. Gas CB Size (Both) RG022 120 / 240 V, 1Ø, 1.0 pf 22 92 22 92 100 120 / 208 V, 3Ø, 0.8 pf 22 76 22 76 80 120 / 240 V, 3Ø, 0.8 pf 22 66 22 66 80 RG027 120 / 240 V, 1Ø, 1.0 pf 27 113 25 104 125 120 / 208 V, 3Ø, 0.8 pf 27 94 25 87 100 120 / 240 V, 3Ø, 0.8 pf 27 81 25 75 90 RG032 120 / 240 V, 1Ø, 1.0 pf 32 133 32 133 150 120 / 208 V, 3Ø, 0.8 pf 32 111 32 111 125 120 / 240 V, 3Ø, 0.8 pf 32 96 32 96 100 277 / 480 V, 3Ø, 0.8 pf 32 48 32 48 60 RG038 120 / 240 V, 1Ø, 1.0 pf 38 158 38 158 175 120 / 208 V, 3Ø, 0.8 pf 38 132 38 132 150 120 / 240 V, 3Ø, 0.8 pf 38 114 38 114 125 277 / 480 V, 3Ø, 0.8 pf 38 57 38 57 60 22 • 27 • 32 • 38 operating data ENGINE FUEL CONSUMPTION Natural Gas Propane (ft³/hr) (m³/hr) (gal/hr) (ft³/hr) (l/hr) RG022 Exercise cycle 42 1.2 0.44 16 1.7 25% of rated load 100 2.8 1.1 40 4.2 50% of rated load 190 5.4 2.1 75 7.8 75% of rated load 255 7.2 2.8 101 10.5 100% of rated load 316 9 3.4 125 13 RG027 Exercise cycle 42 1.2 0.44 16 1.7 25% of rated load 108 3.1 1.2 43 4.5 50% of rated load 197 5.6 2.1 78 8.1 75% of rated load 287 8.2 3.1 114 11.8 100%of rated load 359 10.2 3.9 143 14.8 RG032 Exercise cycle 79 2.2 0.8 30 3.2 25% of rated load 144 4.1 1.7 60 6.3 50% of rated load 226 6.4 2.7 97 10.3 75% of rated load 298 6.4 3.7 132 13.9 100% of rated load 375 10.6 4.6 166 17.5 RG038 Exercise cycle 83 2.3 0.9 31 3.2 25% of rated load 162 4.6 1.7 62 6.6 50% of rated load 255 7.2 2.9 103 10.8 75% of rated load 345 9.8 4 142 15 100% of rated load 437 12.4 5.2 185 19 SURGE CAPACITY IN AMPS Voltage Dip @ < .4 pf 15% 30% RG022 120 / 240 V, 1Ø 55 135 120 / 208 V, 3Ø 40 92 120 / 240 V, 3Ø 35 80 RG027 120 / 240 V, 1Ø 62 170 120 / 208 V, 3Ø 70 120 4 of 9 ® 22 • 27 • 32 • 38 operating data ENGINE COOLING 22 kW 27 kW 32 & 38 kW Air flow (inlet air including alternator and combustion air in cfm / cmm) 2,400 / 68 2,400 / 68 2,200 / 62.3 System coolant capacity (gal / liters) 2.5 / 9.5 2.5 / 9.5 2.5 / 9.5 Heat rejection to coolant (BTU per hr / MJ per hr) 99,000 / 104.5 105,000 / 110.8 145,000 / 153 Maximum operation air temperature on radiator (°F / °C) 140 / 60 Maximum ambient temperature (°F / °C) 122 / 50 COMBUSTION REQUIREMENTS Flow at rated power (cfm / cmm) 68 / 1.9 68 / 1.9 106 / 3 SOUND EMISSIONS Sound output in dB(A) at 23 ft (7 m) with generator in exercise mode* 61 61 58 Sound output in dB(A) at 23 ft (7 m) with generator operating at normal load* 70 70 64 EXHAUST Exhaust flow at rated output (cfm / cmm) 165 / 4.7 180 / 5.1 300 / 8.5 Exhaust temperature at muffler outlet (°C / °F) 482 / 900 538 / 1,000 579 / 1,075 ENGINE PARAMETERS Rated Synchronous rpm 1,800 POWER ADJUSTMENT FOR AMBIENT CONDITIONS Temperature Deration.................................................................................................................................................... 3% for every 10 °C above 25 °C or 1.65% for every 10 °F above 77 °F Altitude Deration (22 & 27 kW) ....................................................................................................................................1% for every 100 m above 183 m or 3% for every 1,000 ft above 600 ft Altitude Deration (32 & 38 kW).................................................................................................................................. 1% for every 100 m above 915 m or 3% for every 1,000 ft above 3,000 ft CONTROLLER FEATURES Two-Line Plain Text LCD Display ............................................................................................................................................................................ Simple user interface for ease of operation. Mode Switch: Auto ................................................................................................................................................................................ Automatic Start on Utility failure. 7 day exerciser. Off ............................................................................................................................................................. Stops unit. Power is removed. Control and charger still operate. Manual .............................................................................................................................Start with starter control, unit stays on. If utility fails, transfer to load takes place. Programmable start delay between 10 – 30 seconds ....................................................................................................................................................................................... 10 sec standard Engine Start Sequence .............................................................................................................................................................. Cyclic cranking: 16 sec on, 7 rest (90 sec maximum duration) Engine Warm-up............................................................................................................................................................................................................................................................. 5 sec Engine Cool-Down ..........................................................................................................................................................................................................................................................1 min Starter Lock-out. ........................................................................................................................................................................Starter cannot re-engage until 5 sec after engine has stopped. Smart Battery Charger ................................................................................................................................................................................................................................................ Standard Automatic Voltage Regulation with Over and Under Voltage Protection ........................................................................................................................................................................ Standard Automatic Low Oil Pressure Shutdown........................................................................................................................................................................................................................ Standard Overspeed Shutdown....................................................................................................................................................................................................................................... Standard, 72 Hz High Temperature Shutdown ..................................................................................................................................................................................................................................... Standard Overcrank Protection.................................................................................................................................................................................................................................................. Standard Safety Fused .............................................................................................................................................................................................................................................................. Standard Failure to Transfer Protection...................................................................................................................................................................................................................................... 5 of 9 ® 22 • 27 • 32 • 38 available accessories Model # Product Description G0071690 Mobile Link® 4G LTE Cellular Accessory Generac's Mobile Link allows you to check the status of your generator from anywhere that you have access to an Internet connection from a PC or with any smart device. You will even be notified when a change in the generator’s status occurs via e-mail or text message. Note: Harness Adapter Kit required. Available in the U.S. only. G006478-0 Kit, Adapter Mobile Link L/C (Required for QT and RG Series) The Harness Adapter Kit is required to make liquid-cooled units compatible with Mobile Link® . G005630-1 - 22, 27, 32 & 38 kW Cold Weather Kit If the temperature regularly falls below 32 °F (0 °C), install a cold weather kit to main- tain optimal battery temperature. Kit consists of battery warmer with thermostat built into the wrap. G005616-0 - 22, 27, 32 & 38 kW Extreme Cold Weather Kit Recommended where the temperature regularly falls below 32 °F (0 °C) for extended periods of time. For liquid cooled units only. G005651-0 Base Plug Kit Add base plugs to the base of the generator to keep out debris. G005703-0 - Bisque Paint Kit If the generator enclosure is scratched or damaged, it is important to touch-up the paint to protect from future corrosion. The paint kit includes the necessary paint to properly maintain or touch-up a generator enclosure. G005656-0 - 22 & 27 kW G005984-0 - 32 & 38 kW Scheduled Maintenance Kit The Liquid-Cooled Scheduled Maintenance Kits offer all the hardware necessary to perform complete maintenance on Generac liquid-cooled generators. G006664-0 Local Wireless Monitor Completely wireless and battery powered, Generac's wireless remote monitor provides you with instant status information without ever leaving the house. G006665-0 Wireless Remote Extension Harness Recommended for use with the Wireless Remote on units up to 60 kW, required for use on units 70 kW or greater. G007000-0 (50 Amps) G007006-0 (100 Amps) Smart Management Module Smart Management Modules (SMM) optimize the performance of a standby generator. They manage large electrical loads upon startup and load shed to aid in recovery when overloaded. In many cases, SMMs can reduce the overall size and cost of the system. G007993-0 E-stop toggle switch for residential installs to NEC2017 6 of 9 ® 631 [24.8] DOOR TYP 427 [16.8] 141 [5.6] 1040 [40.9] 980 [38.6] OVERALL HEIGHT 776 [30.6] OVERALL WIDTH 48 [1.9] TYP 45 [1.8] TYP 1490 [58.7] TYP 1580 [62.2] OVERALL LENGTH 48 [1.9] 629.9 [24.8] CENTER OF GRAVITY (SEE NOTE 5) SERVICE ITEM 2.4L OIL FILL CAP EITHER SIDE OIL DIP STICK RIGHT SIDE OIL FILTER RIGHT SIDE OIL DRAIN HOSE LEFT SIDE RADIATOR DRAIN LEFT SIDE COOLANT RECOVERY BOTTLE LEFT SIDE RADIATOR FILL CAP ROOF TOP AIR CLEANER ELEMENT LEFT SIDE SPARK PLUGS LEFT SIDE MUFFLER SEE NOTE 11 DRIVE BELT EITHER SIDE FAN BELT SEE NOTE 11 BATTERY LEFT SIDE WEIGHT DATA ENGINE/KW KVA ENCLOSURE MATERIAL WEIGHT GENSET ONLY KG [LBS] WEIGHT SHIPPING SKID KG [LBS] SHIPPING WEIGHT KG [LBS] 2.4L 22KW (60HZ) SINGLE PHASE 17.4KVA (50HZ) THREE PHASE 22KVA (50HZ) 7 of 9 ® Drawing #0K8624-C (2 of 2) Protector® QS Series 22 & 27 kW installation layout 100 [3.9] *STUB-UP AREA 51 [2.0] 9 [.4] 104.5 [4.11] *STUB-UP AREA 674 [26.5] 45 [1.8] TYP 1380 [54.3] TYP MOUNTING SLOT CENTERS 1580 [62.2] 735 [28.9] 27 [1.0] TYP 723 [28.5] TYP MOUNTING SLOT CENTERS 776 [30.6] 96 [3.8] 1370 [54.0] 210 [8.3] 28 [1.1] DIMENSIONS: MM [INCH] TOP VIEW LEFT SIDE VIEW REAR VIEW *NOTE - STUB-UP AREA FOR HIGH AND LOW VOLTAGE CONNECTIONS. CIRCUIT BREAKER, NEUTRAL AND CUSTOMER CONNECTION OPENING. 13.5 X 29.5 MOUNTING SLOTS 4X REMOVABLE STUB-UP COVER 8 of 9 ® 1000 [39.4] 50 [2.0] 888 [35.0] OVERALL WIDTH 1171[46.1] OVERALL HEIGHT 47 [1.8] TYP 1857 [73.1] TYP 58 [2.3] TYP 1950 [76.8] OVERALL LENGTH 759 [29.9] DOOR TYP 535 [21.1] 167 [6.6] 768 [30.2] CENTER OF GRAVITY SEE NOTE 5 SERVICE ITEM 2.4L OIL FILL CAP EITHER SIDE OIL DIP STICK RIGHT SIDE OIL FILTER RIGHT SIDE OIL DRAIN HOSE RIGHT SIDE RADIATOR DRAIN HOSE LEFT SIDE COOLANT RECOVERY BOTTLE LEFT SIDE RADIATOR FILL CAP ACCESS ROOF TOP AIR CLEANER ELEMENT RIGHT SIDE SPARK PLUGS LEFT SIDE MUFFLER SEE NOTE 11 DRIVE BELT EITHER SIDE FAN BELT SEE NOTE 11 BATTERY LEFT SIDE WEIGHT DATA ENGINE/KW ENCLOSURE MATERIAL WEIGHT GENSET ONLY KG [LBS] WEIGHT SHIPPING SKID KG [LBS] SHIPPING WEIGHT KG [LBS] 2.4L 32KW AL 556 [1225] 44 [98] 600 [1323] 2.4L 38KW AL 560 [1235] 44 [98] 605 [1333] NOTES: 1. MINIMUM RECOMMENDED CONCRETE PAD SIZE: 1194 (47") WIDE X 2255 (88.8") LONG. REFERENCE INSTALLATION GUIDE SUPPLIED WITH UNIT FOR CONCRETE PAD GUIDELINES. 2. ALLOW SUFFICIENT ROOM ON ALL SIDES OF THE GENERATOR FOR MAINTENANCE AND SERVICING. THIS UNIT MUST BE INSTALLED IN ACCORDANCE WITH CURRENT APPLICABLE NFPA 37 AND NFPA 70 STANDARDS AS WELL AS ANY OTHER FEDERAL, STATE, AND LOCAL CODES. 3. CONTROL PANEL / CIRCUIT BREAKER INFORMATION: 9 of 9 ® Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com ©2019 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Bulletin 0L0036SBY-N 01/26/2021 ® 786 [30.9] 162 [6.4] *STUB-UP AREA 162 [6.4] *STUB-UP AREA 9 [.4] 51 [2.0] 1733 [68.2] 838 [33.0] TYP 50 TYP MOUNTING CENTERS [2.0] 1750 [68.9] TYP MOUNTING SLOTS 1950 [76.8] 850 [33.5] 888 [35.0] 25 [1.0] TYP 116 [4.6] 12 [.5] 217 [8.5] *NOTE - STUB-UP AREA FOR HIGH AND LOW VOLTAGE CONNECTIONS. CIRCUIT BREAKER, NEUTRAL AND CUSTOMER CONNECTION OPENING. 13.5 X 29.5 MOUNTING SLOTS 4X TOP VIEW LEFT SIDE VIEW REMOVABLE STUB-UP ACCESS COVER (SHIPPED LOOSE WITH GENERATOR) TO BE INSTALLED DURING GENERATOR INSTALLATION REAR VIEW 32 & 38 kW installation layout Drawing #0K9268-B (2 of 2) Protector® QS Series - SEE SPECIFICATION SHEET OR OWNERS MANUAL - ACCESSIBLE THROUGH CUSTOMER ACCESS ASSEMBLY DOOR ON REAR OF GENERATOR. 4. REMOVE THE REAR ENCLOSURE COVER PANEL TO ACCESS THE STUB-UP AREAS AS FOLLOWS: - HIGH VOLTAGE CONNECTION INCLUDING AC LOAD LEAD CONDUIT CONNECTION, NEUTRAL CONNECTION, AND BATTERY CHARGER 120 VOLT AC (0.5 AMP MAX) CONNECTION. - LOW VOLTAGE CONNECTION INCLUDING TRANSFER SWITCH CONTROL WIRES. 5. CENTER OF GRAVITY AND WEIGHT MAY CHANGE DUE TO UNIT OPTIONS. 6. BOTTOM OF GENERATOR SET MUST BE ENCLOSED TO PREVENT PEST INTRUSION AND RECIRCULATION OF DISCHARGE AIR AND/OR IMPROPER COOLING AIR FLOW. 7. REFERENCE OWNERS MANUAL FOR LIFTING WARNINGS. 8. MOUNTING BOLTS OR STUDS TO MOUNTING SURFACE SHALL BE 5/8-11 GRADE 5 (USE STANDARD SAE TORQUE SPECS) 9. MUST ALLOW FREE FLOW OF INTAKE AIR, DISCHARGE AIR AND EXHAUST. SEE SPEC SHEET FOR MINIMUM AIR FLOW AND MAXIMUM RESTRICTION REQUIREMENTS. 10. GENERATOR MUST BE INSTALLED SUCH THAT FRESH COOLING AIR IS AVAILABLE AND THAT DISCHARGE AIR FROM RADIATOR IS NOT RECIRCULATED. 11. EXHAUST MUFFLER AND FAN BELT ARE ENCLOSED WITHIN GENERATOR ENCLOSURE, REMOVE FRONT PANEL TO ACCESS. REFERENCE OWNERS MANUAL FOR PERIODIC REPLACEMENT PART LISTINGS. DIMENSIONS: MM [INCH] LEFT SIDE VIEW RADIATOR/EXHAUST DISCHARGE AIR FUEL LINE CONNECTION 3/4" NPT FEMALE COUPLING EXHAUST MUFFLER ENCLOSED WITHIN GENERATOR ENCLOSURE LIFTING PROVISIONS (4 PLACES) SEE NOTES 5, 7 AND CENTER OF GRAVITY DIMENSIONS TOP VIEW RADIATOR/EXHAUST DISCHARGE AIR (BOTH SIDES) AIR INTAKE (BOTH SIDES) REMOVE COVER FOR ACCESS TO RADIATOR FILL CAP BATTERY 12V, GRP 26 NEGATIVE GROUND P/N: 077483 2.5" O.D. EXHAUST OUTLET REAR VIEW REAR ENCLOSURE COVER PANEL SEE NOTE 4 CUSTOMER ACCESS ASSEMBLY, CONTROL PANEL ACCESS, BATTERY CHARGER LOCATED WITHIN SEE NOTE 4 CIRCUIT BREAKER SEE NOTE 3 RIGHT SIDE VIEW VICE ACTION LATCH, ONE PER DOOR, ONE LIFT OFF DOOR PER SIDE OF GENERATOR 32 & 38 kW installation layout Drawing #0K9268-B (1 of 2) Protector® QS Series AL 410.5 [905] 30 [66] 440 [971] 2.4L 27KW (60HZ) SINGLE PHASE 21.6KVA (50HZ) THREE PHASE 27KVA (50HZ) AL 426 [940] 30 [66] 456 [1006] NOTES: 1. MINIMUM RECOMMENDED CONCRETE PAD SIZE: 1092 (43") WIDE X 1885 (74.2") LONG. REFERENCE INSTALLATION GUIDE SUPPLIED WITH UNIT FOR CONCRETE PAD GUIDELINES. 2. ALLOW SUFFICIENT ROOM ON ALL SIDES OF THE GENERATOR FOR MAINTENANCE AND SERVICING. THIS UNIT MUST BE INSTALLED IN ACCORDANCE WITH CURRENT APPLICABLE NFPA 37 AND NFPA 70 STANDARDS AS WELL AS ANY OTHER FEDERAL, STATE, AND LOCAL CODES. 3. CONTROL PANEL / CIRCUIT BREAKER INFORMATION: - SEE SPECIFICATION SHEET OR OWNERS MANUAL - ACCESSIBLE THROUGH CUSTOMER ACCESS ASSEMBLY DOOR ON REAR OF GENERATOR. 4. REMOVE THE REAR ENCLOSURE COVER PANEL TO ACCESS THE STUB-UP AREAS AS FOLLOWS: - HIGH VOLTAGE CONNECTION INCLUDING AC LOAD LEAD CONDUIT CONNECTION NEUTRAL CONNECTION, BATTERY CHARGER 120 VOLT AC (0.5 AMP MAX) CONNECTION. - LOW VOLTAGE CONNECTION INCLUDING TRANSFER SWITCH CONTROL WIRES. 5. CENTER OF GRAVITY AND WEIGHT MAY CHANGE DUE TO UNIT OPTIONS. 6. BOTTOM OF GENERATOR SET MUST BE ENCLOSED TO PREVENT PEST INTRUSION AND RECIRCULATION OF DISCHARGE AIR AND/OR IMPROPER COOLING AIR FLOW. 7. REFERENCE OWNERS MANUAL FOR LIFTING WARNINGS. 8. MOUNTING BOLTS OR STUDS TO MOUNTING SURFACE SHALL BE 5/8-11 GRADE 5 (USE STANDARD SAE TORQUE SPECS) 9. MUST ALLOW FREE FLOW OF INTAKE AIR, DISCHARGE AIR AND EXHAUST. SEE SPEC SHEET FOR MINIMUM AIR FLOW AND MAXIMUM RESTRICTION REQUIREMENTS. 10. GENERATOR MUST BE INSTALLED SUCH THAT FRESH COOLING AIR IS AVAILABLE AND THAT DISCHARGE AIR FROM RADIATOR IS NOT RECIRCULATED. 11. EXHAUST MUFFLER AND FAN BELT ENCLOSED WITHIN GENERATOR ENCLOSURE, REMOVE FRONT PANEL TO ACCESS. REFERENCE OWNERS MANUAL FOR PERIODIC REPLACEMENT PART LISTINGS. DIMENSIONS: MM [INCH] REAR ENCLOSURE COVER PANEL SEE NOTE 4 CIRCUIT BREAKER SEE NOTE 3 CUSTOMER ACCESS ASSEMBLY, CONTROL PANEL ACCESS, BATTERY CHARGER LOCATED WITHIN SEE NOTE 4 REAR VIEW VICE ACTION LATCH, ONE PER DOOR, ONE LIFT OFF DOOR PER SIDE OF GENERATOR RIGHT SIDE VIEW FUEL LINE CONNECTION 3/4" NPT FEMALE COUPLING LEFT SIDE VIEW RADIATOR/EXHAUST DISCHARGE AIR EXHAUST MUFFLER ENCLOSED WITHIN GENERATOR ENCLOSURE RADIATOR/EXHAUST DISCHARGE AIR (BOTH SIDES) AIR INTAKE (BOTH SIDES) BATTERY 12V GRP 26 NEGATIVE GROUND P/N: 077483 REMOVE COVER FOR ACCESS TO RADIATOR FILL CAP TOP VIEW 22 & 27 kW installation layout Drawing #0K8624-C (1 of 2) Protector® QS Series E-stop allows for immediate fuel shutoff and generator shutdown in the event of an emergency. G006510-0 E-Stop resettable switch for commercial installs to NEC2020 E-stop allows for immediate fuel shutoff and generator shutdown in the event of an emergency. G007005-0 Wi-Fi LP Fuel Level Monitor The Wi-Fi enabled LP fuel level monitor provides constant monitoring of the connected LP fuel tank. Monitoring the LP tank’s fuel level is an important step in making sure your generator is ready to run during an unexpected power failure. Status alerts are available through a free application to notify when your LP tank is in need of a refill. A0000018981 Ultrasonic Cleaner Solution An ultra-concentrated anti-corrosive cleaning solution engineered to reach the smallest cavities to clean the toughest contaminants. This water based formula is non-toxic, biodegradable, and safe for both metal and plastic surfaces and is superior in rinsability. A0000019001 All Surface Protectant All Surface Protectant for vinyl, rubber, and plastics creates a barrier that seals & protects surfaces from water and UV rays while renewing the look of the surface. Protector® QS Series Standard Low Battery Protection................................................................................................................................................................................................................................................ Standard 50 Event Run Log....................................................................................................................................................................................................................................................... Standard Future Set Capable Exerciser..................................................................................................................................................................................................................................... Standard Incorrect Wiring Protection........................................................................................................................................................................................................................................ Standard Internal Fault Protection.............................................................................................................................................................................................................................................. Standard Common External Fault Capability .............................................................................................................................................................................................................................. Standard Governor Failure Protection....................................................................................................................................................................................................................................... Standard Protector® QS Series REMOTE MONITORING  Ability to view generator status Monitor generator with a smartphone, tablet, or computer at any time via the Mobile Link application for complete peace of mind.  Ability to view generator Exercise / Run and Total Hours Review the generator's complete protection profile for exercise hours and total hours.  Ability to view generator maintenance information Provides maintenance information for the specific model generator when scheduled maintenance is due.  Monthly report with previous month’s activity Detailed monthly reports provide historical generator information.  Ability to view generator battery information Built in battery diagnostics displaying current state of the battery.  Weather information Provides detailed local ambient weather conditions for generator location. 120 / 240 V, 3Ø 61 103 RG032 120 / 240 V, 1Ø 75 180 120 / 208 V, 3Ø 87 210 120 / 240 V, 3Ø 75 182 277 / 480 V, 3Ø 36 87 RG038 120 / 240 V, 1Ø 75 180 120 / 208 V, 3Ø 87 210 120 / 240 V, 3Ø 75 182 277 / 480 V, 3Ø 36 87 Note: Fuel pipe must be sized for full load. For Btu content, multiply ft³/hr x 2,520 (LP) or ft³/hr x 1,000 (NG) For megajoule content, multiply m³/hr x 93.15 (LP) or m³/hr x 37.26 (NG) Refer to “Emissions Data Sheets” for maximum fuel flow for EPA and SCAQMD permitting purposes. STANDBY RATING: Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. There is no overload capability for this rating. Ratings are in accordance with ISO-3046-1. Design and specifications are subject to change without notice. Protector® QS Series Battery Charge Alternator 12 Volt 30 Amp Static Battery Charger 2.5 Amp Recommended Battery (battery not included) Group 26 (22, 27, 32 & 38 kW) System Voltage 12 Volts GOVERNOR SPECIFICATIONS Type Electronic Frequency Regulation Isochronous Steady State Regulation ± 0.25% VOLTAGE REGULATION Type Electronic Sensing Single Phase Regulation ± 1% GENERATOR SPECIFICATIONS Type Synchronous Rotor Insulation Class H (22 & 27 kW) or F (32 & 38 kW) Stator Insulation Class H Telephone Interference Factor (TIF) <50 Alternator Output Leads 1-Phase 4 wire Alternator Output Leads 3-Phase 6 wire Bearings Sealed Ball Coupling Flexible Disc Excitation System Direct (All ratings in accordance with BS5514, ISO3046, ISO8528, SAE J1349 and DIN6271) Protector® QS Series  GENERAC TRANSFER SWITCHES. Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is the GENERAC product line is offered with its own transfer systems and controls for total system compatibility. PROTECTOR® QS SERIES Standby Generators Liquid-Cooled Gaseous Engine *Only if located away from doors, windows, and fresh air intakes, and unless otherwise directed by local codes. Please review install guide for more details.