Loading...
HomeMy WebLinkAbout23200 - Perry Lopez.pdf55' 11" 266' 10" 265' 9" 101' 2" 57' 2" 300' 4" UM MSP 39'-10" 154'-4" 28'-7" 86'-3" 1 2 3 PROJECT DESCRIPTION: SHEET INDEX PV-1 PLOT PLAN & VICINITY MAP PV-2 ROOF PLAN & MODULES PV-2A STRING LAYOUT PV-3 RACKING DETAIL PV-4 ATTACHMENT DETAIL PV-5 ELECTRICAL LINE DIAGRAM PV-6 WIRING CALCULATIONS PV-7 PLACARDS PLOT PLAN & VICINITY MAP PV-8+ EQUIPMENT SPECIFICATIONS HOUSE PHOTO VICINITY MAP PV-1 SCALE: 1/32" = 1' PV-1 SCALE: NTS PV-1 SCALE: NTS PROJECT SITE PLOT PLAN & VICINITY MAP REV SHEET NAME SHEET SIZE SHEET NUMBER PERRY LOPEZ 11201 N ECHO CREST DR, INDIANAPOLIS, IN 46280, USA ANSI B 11" X 17" DESCRIPTION DATE REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-1 SOLAR ENERGY SOLUTIONS 1038 BRENTWOOD CT, STE B LEXINGTON, KY 40511 TEL: (877) 312-7456 JOB NUMBER 23200 08/21/2023 19 X 410 SILFAB SIL-410 BG (410W) MODULES ROOF MOUNTED SOLAR PHOTOVOLTAIC SYSTEM SYSTEM SIZE: 7.790KW DC STC EQUIPMENT SUMMARY 19 SILFAB SIL-410 BG (410W) MODULES 18" FIRE SETBACK 18" FIRE SETBACK 18" FIRE SETBACK 18" FIRE SETBACK 18" FIRE SETBACK 18" FIRE SETBACK 18" FIRE SETBACK 18" FIRE SETBACK 18" FIRE SETBACK 18" FIRE SETBACK 36" FIRE SETBACK ACD INV UM ES BUG MSP 2xPW SD SD ROOF PLAN & MODULES REV SHEET NAME SHEET SIZE SHEET NUMBER PERRY LOPEZ 11201 N ECHO CREST DR, INDIANAPOLIS, IN 46280, USA ANSI B 11" X 17" DESCRIPTION DATE REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-2 SOLAR ENERGY SOLUTIONS 1038 BRENTWOOD CT, STE B LEXINGTON, KY 40511 TEL: (877) 312-7456 JOB NUMBER 23200 08/21/2023 ROOF DESCRIPTION ROOF TYPE ASPHALT SHINGLE ROOF ROOF ROOF TILT AZIMUTH TRUSS SIZE TRUSS SPACING #1 45° 147° 2"x6" 16" O.C. #2 30° 57° 2"x6" 16" O.C. ARRAY AREA WITH ROOF AREA ROOF # OF MODULES ARRAY AREA (Sq. Ft.) ROOF AREA (Sq. Ft.) ROOF ACD INV UM ES BUG MSP 2xPW SD SD 1 STRING LAYOUT PV-2A SCALE: 3/32" = 1'-0" STRING LAYOUT REV SHEET NAME SHEET SIZE SHEET NUMBER PERRY LOPEZ 11201 N ECHO CREST DR, INDIANAPOLIS, IN 46280, USA ANSI B 11" X 17" DESCRIPTION DATE REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-2A SOLAR ENERGY SOLUTIONS 1038 BRENTWOOD CT, STE B LEXINGTON, KY 40511 TEL: (877) 312-7456 JOB NUMBER 23200 08/21/2023 STRING #1(09) BILL OF MATERIALS EQUIPMENT QTY DESCRIPTION SOLAR PV MODULES 19 SILFAB SIL-410 BG (410W) MODULES INVERTER 1 SOLAREDGE SE7600H-US(240V) INVERTER OPTIMIZERS 19 SOLAREDGE S440 OPTIMIZER AC DISCONNECT 1 200A FUSED AC DISCONNECT WITH (2) 200A FUSES,240 NEMA 3R, UL LISTED ATTACHMENTS 46 IRONRIDGE FLASHFOOT-2 ATTACHMENTS RAILS 11 EVEREST CR-48XL RAIL RACKING SYSTEM(166") RAIL SPLICE 4 SPLICE KIT MID CLAMPS 28 MID CLAMPS END CLAMPS 20 END CLAMPS / STOPPER SLEEVE GROUNDING LUG 10 GROUNDING LUG STRING #2(10) 11201 N ECHO CREST DR (E) FRONT OF HOUSE (E) BACK OF HOUSE 13'-4" 15'-7" 4'-6" 12'-4" 1" 32'-11" 13'-10" 3'-5" 24'-8" 9'-1" 12'-4" 5'-4" 13'-10" 10'-4" RACKING DETAIL REV SHEET NAME SHEET SIZE SHEET NUMBER PERRY LOPEZ 11201 N ECHO CREST DR, INDIANAPOLIS, IN 46280, USA ANSI B 11" X 17" DESCRIPTION DATE REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-3 SOLAR ENERGY SOLUTIONS 1038 BRENTWOOD CT, STE B LEXINGTON, KY 40511 TEL: (877) 312-7456 JOB NUMBER 23200 08/21/2023 1 RACKING DIAGRAM PV-3 SCALE: 1/8"=1'-0" REV SHEET NAME SHEET SIZE SHEET NUMBER PERRY LOPEZ 11201 N ECHO CREST DR, INDIANAPOLIS, IN 46280, USA ANSI B 11" X 17" DESCRIPTION DATE REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-4 SOLAR ENERGY SOLUTIONS 1038 BRENTWOOD CT, STE B LEXINGTON, KY 40511 TEL: (877) 312-7456 JOB NUMBER 23200 08/21/2023 ATTACHMENT ATTACHMENT DETAILS SCALE: NTS 1 PV-4 2"X6" TRUSSES @ 16" O.C. 2 ATTACHMENT DETAIL (FRONT VIEW) PV-4 SCALE: NTS SEE (2/PV-4) FOR ENLARGED VIEW PV MODULES EVEREST CR-48XL RAIL 2"X6" TRUSSES @ 16" O.C. PV MODULE MID CLAMP (E) ASPHALT SHINGLE ROOF IRONRIDGE FLASH FOOT2 ATTACHMENTS FLASHING 5/16"x3.5" SS LAG BOLT WITH MIN 21 2" THREAD EMBEDMENT, SEALED PENETRATION REV SHEET NAME SHEET SIZE SHEET NUMBER PERRY LOPEZ 11201 N ECHO CREST DR, INDIANAPOLIS, IN 46280, USA ANSI B 11" X 17" DESCRIPTION DATE REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-5 SOLAR ENERGY SOLUTIONS 1038 BRENTWOOD CT, STE B LEXINGTON, KY 40511 TEL: (877) 312-7456 JOB NUMBER 23200 08/21/2023 ELECTRICAL LINE DIAGRAM 1 ELECTRICAL LINE DIAGRAM PV-5 SCALE: NTS SERVICE INFO UTILITY PROVIDER: MAIN SERVICE VOLTAGE: MAIN PANEL BRAND: MAIN SERVICE PANEL: MAIN CIRCUIT BREAKER RATING: MAIN SERVICE LOCATION: SERVICE FEED SOURCE: 240V 200A 200A UNDERGROUND DUKE ENERGY INDIANA INC EATON INSIDE BASEMENT (19) SILFAB SIL-410 BG (410W) MODULES (01) SOLAREDGE SE7600H-US(240V) INVERTER (19) SOLAREDGE S440 OPTIMIZER (01) STRING OF 09 MODULES (01) STRING OF 10 MODULES (CONNECTED IN SERIES PER STRING) GATEWAY :- 01 TESLA BACKUP GATEWAY 2.0 BATTERY:- 02 TESLA POWERWALL 2.0 Conduit Conductor Schedule (ALL CONDUCTORS MUST BE COPPER) Tag # 1 1 2 2 3 3 Bare Copper Ground (EGC) PV WIRE THWN-2 THWN-2 - Ground EXPECTED WIRE TEMP (In Celsius) NO. OF CURRENT CARRYING CONDUCTORS CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) CIRCUIT CONDUCTOR SIZE 1 10 AWG 2 32 TEMP. CORRECTION PER TABLE (310.16) CIRCUIT CONDUCTOR AMPACITY 40A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A) (6) 1.25 X 15(OPTIMIZER MAXIMUM OUTPUT CURRENT) 18.75A DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 TEMP. CORRECTION PER TABLE (310.16) X CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) X CIRCUIT CONDUCTOR AMPACITY 38.4A Result should be greater than (18.75A) otherwise less the entry for circuit conductor size and ampacity REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8 (A) (6) 1.25 X15 (OPTIMIZER MAXIMUM OUTPUT CURRENT) 18.75A DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 TEMP. CORRECTION PER TABLE (310.16) X CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) X CIRCUIT CONDUCTOR AMPACITY 30.72A Result should be greater than (18.75A) otherwise less the entry for circuit conductor size and ampacity DC CONDUCTOR AMPACITY CALCULATIONS: FROM JUNCTION BOX TO INVERTER 1-2: DC CONDUCTOR AMPACITY CALCULATIONS: ARRAY TO JUNCTION BOX : 0.96 REV SHEET NAME SHEET SIZE SHEET NUMBER PERRY LOPEZ 11201 N ECHO CREST DR, INDIANAPOLIS, IN 46280, USA ANSI B 11" X 17" DESCRIPTION DATE REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-6 SOLAR ENERGY SOLUTIONS 1038 BRENTWOOD CT, STE B LEXINGTON, KY 40511 TEL: (877) 312-7456 JOB NUMBER 23200 08/21/2023 WIRING CALCULATIONS ELECTRICAL NOTES 1.) ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. REV SHEET NAME SHEET SIZE SHEET NUMBER PERRY LOPEZ 11201 N ECHO CREST DR, INDIANAPOLIS, IN 46280, USA ANSI B 11" X 17" DESCRIPTION DATE REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-7 SOLAR ENERGY SOLUTIONS 1038 BRENTWOOD CT, STE B LEXINGTON, KY 40511 TEL: (877) 312-7456 JOB NUMBER 23200 08/21/2023 PLACARDS CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN AT: MAIN SERVICE/UTILITY METER RATED MAXIMUM POWER- . POINT CURRENT (Imp) . RATED MAXIMUM POWER- . POINT VOLTAGE (Vmp) . MAXIMUM SYSTEM . VOLTAGE (VOC) . MAXIMUM CIRCUIT . CURRENT (Isc) . 480 400 30 19.48 A V LABEL LOCATION: DC DISCONNECT, INVERTER (PER CODE: CEC690.53) V A INVERTER #1 LABEL LOCATION: AT MSP : NEC 705.10 & 690.56 (B) SOLAR DISCONNECT LABEL LOCATION: AC DISCONNECT, POINT OF INTERCONNECTION (PER CODE: CEC690.13(B)) PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OPERATING CURRENT 32.0 AMPS AC NOMINAL OPERATING VOLTAGE 240 VOLTS LABEL LOCATION: DISCONNECT, POINT OF INTERCONNECTION (PER CODE: CEC690.13(B)) WARNING: PHOTOVOLTIC POWER SOURCE Per NEC 690.31(G) (3)(4) Place on all source markings. REV SHEET NAME SHEET SIZE SHEET NUMBER PERRY LOPEZ 11201 N ECHO CREST DR, INDIANAPOLIS, IN 46280, USA ANSI B 11" X 17" DESCRIPTION DATE REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-8 SOLAR ENERGY SOLUTIONS 1038 BRENTWOOD CT, STE B LEXINGTON, KY 40511 TEL: (877) 312-7456 JOB NUMBER 23200 08/21/2023 EQUIPMENT SPECIFICATION REV SHEET NAME SHEET SIZE SHEET NUMBER PERRY LOPEZ 11201 N ECHO CREST DR, INDIANAPOLIS, IN 46280, USA ANSI B 11" X 17" DESCRIPTION DATE REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-9 SOLAR ENERGY SOLUTIONS 1038 BRENTWOOD CT, STE B LEXINGTON, KY 40511 TEL: (877) 312-7456 JOB NUMBER 23200 08/21/2023 EQUIPMENT SPECIFICATION REV SHEET NAME SHEET SIZE SHEET NUMBER PERRY LOPEZ 11201 N ECHO CREST DR, INDIANAPOLIS, IN 46280, USA ANSI B 11" X 17" DESCRIPTION DATE REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-10 SOLAR ENERGY SOLUTIONS 1038 BRENTWOOD CT, STE B LEXINGTON, KY 40511 TEL: (877) 312-7456 JOB NUMBER 23200 08/21/2023 EQUIPMENT SPECIFICATION REV SHEET NAME SHEET SIZE SHEET NUMBER PERRY LOPEZ 11201 N ECHO CREST DR, INDIANAPOLIS, IN 46280, USA ANSI B 11" X 17" DESCRIPTION DATE REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-11 SOLAR ENERGY SOLUTIONS 1038 BRENTWOOD CT, STE B LEXINGTON, KY 40511 TEL: (877) 312-7456 JOB NUMBER 23200 08/21/2023 EQUIPMENT SPECIFICATION REV SHEET NAME SHEET SIZE SHEET NUMBER PERRY LOPEZ 11201 N ECHO CREST DR, INDIANAPOLIS, IN 46280, USA ANSI B 11" X 17" DESCRIPTION DATE REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-12 SOLAR ENERGY SOLUTIONS 1038 BRENTWOOD CT, STE B LEXINGTON, KY 40511 TEL: (877) 312-7456 JOB NUMBER 23200 08/21/2023 EQUIPMENT SPECIFICATION REV SHEET NAME SHEET SIZE SHEET NUMBER PERRY LOPEZ 11201 N ECHO CREST DR, INDIANAPOLIS, IN 46280, USA ANSI B 11" X 17" DESCRIPTION DATE REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-13 SOLAR ENERGY SOLUTIONS 1038 BRENTWOOD CT, STE B LEXINGTON, KY 40511 TEL: (877) 312-7456 JOB NUMBER 23200 08/21/2023 EQUIPMENT SPECIFICATION REV SHEET NAME SHEET SIZE SHEET NUMBER PERRY LOPEZ 11201 N ECHO CREST DR, INDIANAPOLIS, IN 46280, USA ANSI B 11" X 17" DESCRIPTION DATE REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-14 SOLAR ENERGY SOLUTIONS 1038 BRENTWOOD CT, STE B LEXINGTON, KY 40511 TEL: (877) 312-7456 JOB NUMBER 23200 08/21/2023 EQUIPMENT SPECIFICATION Place on Conduit every 10 ft. (IFC 605.11.1.1 and IFC 605.11.1.2) WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE. PER NEC 705.12(B)(2)(3)(b) PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN PER NEC 690.56(C) WARNING DUAL POWER SOURCE SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM 4" x 2", RED AND WHITE LETTERS PER NEC 705.12(D)(3) & NEC 690.64 ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING PER NEC 690.13 (B) THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, SHALL NOT EXCEED AMPACITY OF BUSBAR WARNING PER NEC 705.12(B)(2)(3)(c) Per NEC NEC 690.13(B) PHOTOVOLTIC AC DISCONNECT WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE. PER NEC 705.12(B)(2)(3)(b) AC DISCONNECT INVERTER 11201 N ECHO CREST DR SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. LABEL LOCATION: NO MORE THAT 1 M (3 FT) FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. 6" 3.5" BACKUP GATEWAY(INSIDE BASEMENT) 1 OF 1 E STOP BUTTON MAIN SERVICE PANEL (INSIDE BASEMENT) FUSED AC DISCONNECT TESLA BATTERY UTILITY METER SE 7600H-US RAPID SHUTDOWN DISCONNECT SWITCH PV ARRAY 1 OF 2 2.) ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT. 3.) WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. 4.) WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. 5.) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. 6.) WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. 7.) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. 8.) MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. 9.) MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG. 10.) THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE NUMBER OF CURRENT CARRYING CONDUCTORS IN EMT 4-6 7-9 10-20 PERCENT OF VALUES .80 .70 .50 AMBIENT TEMPERATURE SPECS AMBIENT TEMP (HIGH TEMP 2%) RECORD LOW TEMP -23° 32° CONDUIT HEIGHT 0.5" ROOF TOP TEMP 55° CONDUCTOR TEMPERATURE RATE 90° MODULE TEMPERATURE COEFFICIENT OF Voc -0.279%/°C SOLAR MODULE SPECIFICATIONS MANUFACTURER MODEL # PMAX VMP IMP VOC ISC 410W SILFAB MODULE DIMENSION 38.07A 10.77A 45.92V 11.30A 73.4"x 40.5" x 1.4"D (In Inch) INVERTER SPECIFICATIONS 1: MANUFACTURER MODEL # SE 7600H-US SOLAREDGE NOMINAL AC POWER 7600W NOMINAL OUTPUT VOLTAGE 240V NOMINAL OUTPUT CURRENT 32.0A AC CONDUCTOR AMPACITY CALCULATIONS: FROM INVERTER TO BACKUP GATEWAY No. OF INVERTER NO. OF CURRENT CARRYING CONDUCTORS CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) CIRCUIT CONDUCTOR SIZE 1 8 AWG 2 1 TEMP. CORRECTION PER TABLE (310.16) 0.94 CIRCUIT CONDUCTOR AMPACITY 50A EXPECTED WIRE TEMP (In Celsius) 32 REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(B) 1.25 X MAX INVERTER OUTPUT CURRENT 40.0A DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 TEMP. CORRECTION PER TABLE (310.16) X CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) X CIRCUIT CONDUCTOR AMPACITY 47A Result should be greater than (50.0A) otherwise less the entry for circuit conductor size and ampacity EXPECTED WIRE TEMP (In Celsius) NO. OF CURRENT CARRYING CONDUCTORS CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) CIRCUIT CONDUCTOR SIZE 0.80 10 AWG 4 32 TEMP. CORRECTION PER TABLE (310.16) CIRCUIT CONDUCTOR AMPACITY 40A 0.96 AC CONDUCTOR AMPACITY CALCULATIONS: FROM BACKUP GATEWAY TO METER No. OF INVERTER NO. OF CURRENT CARRYING CONDUCTORS CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) CIRCUIT CONDUCTOR SIZE 1 3/0 AWG 2 1 TEMP. CORRECTION PER TABLE (310.16) 0.94 CIRCUIT CONDUCTOR AMPACITY 200A EXPECTED WIRE TEMP (In Celsius) 32 REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(B) 1.25 X MAX INVERTER OUTPUT CURRENT 100A DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 TEMP. CORRECTION PER TABLE (310.16) X CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) X CIRCUIT CONDUCTOR AMPACITY 188.0A Result should be greater than (100A) otherwise less the entry for circuit conductor size and ampacity SILFAB SIL-410 BG (410W) Description Wire Gauge # of Conductors/Color Conduit Type Conduit Size 10 AWG 6 AWG 10 AWG 8 AWG 10 AWG 2 (1V+, 1V-) 1 BARE 4 (2V+, 2V-) B/R 1 (GRN) 3 (1L1, 1L2,1N) B/R/N 1 (GRN) N/A-Free Air N/A-Free Air N/A-Free Air N/A-Free Air EMT EMT 1" 1" THWN-2 THWN-2 - Ground 4 4 EMT EMT 1" 1" THWN-2 THWN-2 - Ground 3/0 AWG 6 AWG 3 (1L1, 1L2,1N) B/R/N 1 (GRN) EMT EMT 10 AWG 2" 2" 5 5 THWN-2 THWN-2 - Ground 3/0 AWG - 3 (1L1, 1L2,1N) B/R/N EMT 2" - - - CTRL N G (N) BACKUP GATEWAY TESLA P/N 1118431-XX-X 200A MAX, NEMA 3R (INSIDE-HOUSE WALL) TO 4 TO 6 L1 L2 30A/2P N G 3 4 2 TO (4) [24-16] AWG THWN-2 (3) [10-8] AWG THWN-2 (1) [10-8] AWG GND CTRL L1 L2 40A/2P 200A (E) (E) MAIN SERVICE PANEL, 200A RATED, 240V ( INSIDE BASEMENT) L1 L2 N M BI-DIRECTIONAL UTILITY METER METER NO: 3210100000 1-PHASE, 3-W, 120V/240V TO UTILITY GRID (N) E STOP BUTTON (NEAR UTILITY METER E N G N G L1 L2 L1 L2 (N) AC DISCONNECT: 200A FUSED, (2) 200A FUSES, 240V NEMA 3R, UL LISTED GEC 5 L1 L2 30A/2P 2 TO CTRL (N)SILFAB SIL-410 BG (410W) MODULES 1 = DC 1 2 3 - + - + + - + - + - + - + - + - = = = = = = = = = = - + - + SOLAREDGE: SE7600H-US INVERTER OUTPUT: 240VAC, 32.0A 99% CEC WEIGHTED EFFICIENCY NEMA 3R, UL LISTED, INTERNAL GFDI WITH INTEGRATED DC DISCONNECT SOLADECK J BOX 08 09 1 2 3 - + - + + - + - + - + - + - + - = = = = = = = = = = - + - + 09 10 AC SOLAREDGE POWER OPTIMIZER S440 RATED DC INPUT POWER - 440 WATTS MAXIMUM INPUT VOLTAGE - 60 VDC MPPT RANGE - 8 TO 60 VDC MAXIMUM INPUT CURRENT - 14.5 ADC MAXIMUM OUTPUT CURRENT - 15 ADC STRING LIMITATIONS - 8 TO 25 OPTIMIZERS, 5700 WATTS STC PER STRING MAXIMUM 2 (N)POWERWALL TESLA P/N 1092170-XX-X 5KW, 13.5KWH NEMA 3R (INSIDE HOUSE) (N)POWERWALL TESLA P/N 1092170-XX-X 5KW, 13.5KWH NEMA 3R (INSIDE HOUSE) AREA COVERED BY ARRAY (%) #1 9 185.79 449.68 41.32 #2 10 206.44 1370.04 15.07 LEGEND INV - INVERTER - MAIN SERVICE PANEL - VENTS, (ROOF OBSTRUCTION) - TRUSSES - CONDUIT UM - UTILITY METER 1 PV-2 ROOF PLAN & MODULES SCALE: 3/32" = 1'-0" - SOLAREDGE S440 OPTIMIZER - CHIMNEY MODULE TYPE, DIMENSIONS & WEIGHT SD - SOLADECK J BOX NUMBER OF MODULES = 19 MODULES MODULE TYPE = SILFAB SIL-410 BG (410W) MODULES MODULE WEIGHT = 45.8 LBS / 20.8 KG. MODULE DIMENSIONS = 73.4"x 40.5" = 20.64 SF UNIT WEIGHT OF ARRAY = 2.22PSF SILFAB SIL-410 BG (410W) MODULES 40.5" 73.4" ACD - FUSED AC DISCONNECT MSP BUG - BACKUP GATEWAY (N) EVEREST CR-48XL RACKING SYSTEM - ROOF ATTACHMENT ROOF #1 (9) SILFAB SIL-410 BG (410W) MODULES ES - EMERGENCY STOP BUTTON 10/2” MC CONDUIT (N) BACKUP GATEWAY(INSIDE BASEMENT) (N) EMERGENCY STOP BUTTON (E) UTILITY METER (E) MAIN SERVICE PANEL (INSIDE BASEMENT) (N) FUSED AC DISCONNECT (46) PV ATTACHMENTS @ 48" O.C. (19) SOLAREDGE S440 OPTIMIZER (N) SE7600H-US (240V) INVERTERS (N) 2xTESLA POWERWALL PW - POWERWALL 11201 N ECHO CREST DR (E) FRONT OF HOUSE (E) BACK OF HOUSE ROOF #1 TILT - 45° AZIM. - 147° ROOF #2 TILT - 30° AZIM. - 57° (N) SOLADECK J BOX (TYP.) 01 SOLAREDGE SE7600H-US(240V) INVERTER 19 SOLAREDGE S440 OPTIMIZER GATEWAY :- 01 TESLA BACKUP GATEWAY 2.0 BATTERY:- 02 TESLA POWERWALL 2.0 ROOF ACCESS POINT ROOF ACCESS POINT SHALL NOT BE LOCATED IN AREAS THAT REQUIRE THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND SHALL BE LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS. PROJECT SITE EXISTING NEW (E) (N) DESCRIPTION DESIGN SPECIFICATIONS EXPOSURE CATEGORY = C WIND SPEED = 115 MPH GROUND SNOW LOAD = 15 PSF ZONING = RESIDENTIAL CONSTRUCTION = SINGLE FAMILY ROOF ACCESS POINT GOVERNING CODES THE BUILDING CODES OF INDIANA ADOPT THE 2014 INDIANA BUILDING CODE (IBC 2014) 2020 INDIANA RESIDENTIAL CODE (IRC 2020) 2014 INDIANA FIRE CODE (IFC 2014) 2014 INDIANA MECHANICAL CODE (IMC 2014) 2014 INDIANA FUEL GAS CODE (IFGC 2014) 2012 INDIANA PLUMBING CODE (IPC 2012) 2009 INDIANA ELECTRICAL CODE ROOF #1 (9) SILFAB SIL-410 BG (410W) MODULES 1-STORY HOUSE (E) UTILITY METER (E) MAIN SERVICE PANEL (INSIDE BASEMENT) ROOF #2 (10) SILFAB SIL-410 BG (410W) MODULES 11201 N ECHO CREST DR PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPERTY LINE ROOF ACCESS POINT EXISTING DRIVEWAY