HomeMy WebLinkAbout06110056 State Release
. - ~
Would you like to reduce your turnaround time?
ELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INDIANA AT
efile24-7@dhs..in.gov, Or VISIT OUR WEB SITE AT www.in.govtdhs/branchesfplanreviewlindex.html
Project number
Release date
CONSTRUCTION DESIGN RELEASE
State Form 41191 (R915-98)
Report Printed on: November 8,2006
E-FiJed, No hard
322144 copy will be mailed 11/08/06
Construction type Occupancy classification
I~B B
INDIANA 02
, ~ 0000
Scope of release
ARCH
Indiana Department of Homeland Security
DIVISION OF FIRE SAFETY I PLAN REVIEW
402 W. Washington St., Room E245
Indianapolis, IN 46204
Type of release
Standard
Project name
Indiana Bureau of Motor Vehicles Cannel
Available At. Your Local Licence Branch
SUPPORT HOOSIER SAFETY
To: Owner I Architect I Engineer
Axis
Dandridge Drew White 19400087
618 E Market St
Indianapolis IN
Street address
12955 Old Meridian 5t
Suite 107
46202
County
HAMILTON
City
CARMEL
Fax & e-mail: 3172648165, kosborne@axisarch.com
I
The plans, specifications and application submitted for the above referenced project have been reviewed for compliance with the applicable rules of
the Fire Prevention and Building Safety Commission. The project is released for construction subject to, but not necessarily limited to, the conditions
listed'below."THIS 'IS"NOT A BUILDING' PERMIT:'AlI'required'local 'permits' and' licenses'must 'be' obtained'prior to beginning' construction work. All
construction work must be in full compliance with all applicable State rules. Any changes in the released plans and/or specifications'must be filed with
and released by this Office before any work i~:altered.jThiS','rel~ase ,may besuspendedror revoked if it is determined to b~:iS,sued in,error, in violation
9f any rules of the Commission or if it is b??ed:'o)1, incdrrect 'or ir~ufrcieht info~~tio~:' Thi~ release shall expire by~limitat10'n"and become null and
void, if the work authorized is not commenced'wit~iri one (l),year from the above,date..
CONDITIONS: ' ,
Note :(A 1A & A 1 B): In accordance'wit~_'the affidavit sworn under penalties of perjury in the application, for construction design release the plans
and specifications filed in conjunction with this project shall comply with all of the applicable rules and laws of Fire Prevention and Building Safety
C;:ommission. Providing false information constitutes an act of perjury, which is a Class 0 felony punishable by a prison term and a fine up to $10,000.
In accordance with Section 190f the General Administrative Rules (675 lAC 12-6-19) a complete set of plans and specifications that conform
exactly to the design that~was released 'by the office of the state building commissioner shall be maintained on the construction jobsite as well as a
qopy of the designrele~se. .
i4G0615A
j
'3B1004G
,3B1004E
3B1004D1~~
3B1004F
3B1112
4G0411AA
3C0501A
3B0602
This is a partially submitted and released project. Subsequent submittals shall be accompanied by a
complete9,standard I partial form (ACDR) and proper fees in accordance with 675 lAC 12~6-15(c),
'Fire-resi~tance-rated corridors shall be continuous from the point of entry and shall not be
interrupted by intervening rooms in accordance with Section 1004,3,2.5, IBC (675 lAC 13"2.4).
Where more than one exit or exit access doorway is required, the exit access shall be arranged
such that there are no dead ends in corridors more than 20 feet in length in accordance with Section
1004.3.2.3, IBC (675 lAC 13~2.4).
~Exirci5rridi5fsshall~be "firiFfesistance rated in ' accbrdanceWith Sectibn1 004.3.2.1 and Table
1004.3.2.1, IBC (675 lAC 13-2.4).
Corridors shall not serve as supply, return, exhaust, relief, or ventilation air ducts or plenums in
accordance with Section 1004.3.2.4, IBC (675 lAC 13-2.4).
Buildings shall be accessible to persons with disabilities in accordance with Section 1.2 (1 through
5) and (2), Part 1, Chapter 11, IBC (675 lAC 13-2.4).
No change in the character or use of any building or structure shall be permitted which shall cause
the building or structure to be classiifed within a different occupancy group or within a different
division of the same occupancy group, unless such building or structure complies with or is made to
comply with the current rules of the Indiana Fire Prevention and Building Safety Commission for new
construction for the proposed revised use of the building in accordance with 675 lAC 12~4~11 (c).
Buildings that are heated or mechanically cooled shall be constructed so as to provide the required
thermal performance of the various components in accordance with Section 501.1, IECC (675 lAC
19-3-1).
Exterior walls shall have fire~resistance ratings in accordance with Table 602, IBC (675 lAC 13~2.4).
Page 1/2
;- "
Would you like to reduce your turnaround time?
ELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INDIANA AT
efile24-7@dhs..in.gov, Or VISIT OUR WEB SITE AT www.ln.gov/dhs/branches/planreviewlindex.html
Please be advised that if an administrative review of this action is desired, a written petition for review must be filed at the above address with the
Fire Prevention and Building Safety Commission identifying the matter for which a review is sought no later than eighteen (18) days from the above -
stated date, unless the eighteenth day falls on a Saturday, a Sunday, a legal holiday under State statute, or a day in which the Department of Fire
and Building Services is closed during normal business hours. In the latter case, the filing deadline will be the first working day thereafter. If you
choose to petition, and the before-mentioned procedures are followed, your petition for review will be granted, and an administrative proceeding will
be conducted by an administrative law judge of the Fire Prevention and Building Safely Commission. If a petition for review is not filed. this Order will
be final, and you must comply with its requirements.
Filed By Code review official Code Enforcement & Plan Review Branch Director
ERIK KASSIG -tJ~d/S~
Address (name,title of local official,street,city,state and ZIP code
DEPT OF COMMUNITY SERVICE State Fire Marshal V1?,O~
JIM BLANCHARD
ONE CIVIC SQUARE
CARMEL. IN 46032
Fax & e-mail: 3175712499,jblanchard@carmel.in.gov
Page 2/2