HomeMy WebLinkAboutSignage PlansTYPICAL VIEW
scale: 1/4”=1’01END VIEW
scale: 1/4”=1’02 107"88"55 1/2"240"
120"120"
216" (STEEL STRUCTURE)
64"64"
18"
Cabinet to be painted [P1] on
all sides. Digitally printed flex
face to match [P1] logo color
Steel tube framework
painted [P2] on all sides
62 1/4"107"108 1/2"22"240"
PLAN VIEW18"64 1/4"Top of cabinets to have
lift points
2” x 2” x 1/4” wall steel angle
welded to tubing. 3/4” dia.
mounting holes
2” sq. steel tube bolted to
upright structure
1/4” thick steel flange plate
welded to 2” steel angle.
6 1/4"6 1/4"6 1/4"6 1/4"6 1/4"
67 3/8"75 3/8"67 3/8"
Horizontal support bolted to
angled support arms 120 V
Revise & resubmit
Approved
DESIGN STATUS:
BY:
DATE:
Sign Type: E1
Description: Rooftop Signage
Scale: Noted
Project: Merchants Bank
Date: 04/26/19 By: MW
* * *
Drawing Notes:
Construction View:
[P1] TBD
Standard Color
[P2] TBD
Standard Color
5349 W 86th Street • Indianapolis, IN 46268
317|872|8722
SignworksThinks.com
These drawings/and or the accompanying specications as instruments of service are
the exclusive property of Signworks, Inc. and their use and publication shall be restricted
to the original site for which they were prepared. Reuse reproductions or publications by any
method, in whole or part, is prohibited except by written authorization from Signworks, Inc.
Copyright and ownership of these plans and or specications shall remain with the designer
without prejudice and visual contact with them shall constitute Prima Fascia Evidence of
these restrictions. Signworks, Inc. shall be entitled to further compensation equal to
one hundred and fty (150%) of the original project fee, the total cost of production and
installation per occurrence, and the reasonable costs of collection for any unauthorized
use of these drawings and or specications or any derivative works thereof.
CONSTRUCTION VIEW
scale: 1/4”=1’01107"88"55 1/2"240"
120"120"
216" (STEEL STRUCTURE)
64"64"124 1/2"79 1/4"45
1
/
4
"
STEEL STRUCTURE LAYOUT
scale: 1/4”=1’02107"216"
2"69 3/8"69 3/8"69 3/8"2"2"2"28 3/4"27 3/4"24 3/4"24 3/4"SC 2104 Retro frame with
SC 2121 Retro bleed
cover. 1 1/2” sq. alum.
tube framework with
0.090” thick alum.
sheeting
Illumination from (1) 117”,
(1) 108”, and (1) 96” SS
Principal Tap Out Stik.
Internal power supplies
and disconnect switch
Power out location TBD
2” steel angle on back
of cabinet to bolt to
steel mounting frame
2” sq. steel frame (1/4”
wall)5"Uprights from
2” sq. steel tubing
(1/4” wall). Bolted
to main structure
with 1/2” dia. bolts.
Removable for
transport
T YPICAL SECTION VIEW
scale: 3”=1’
A1
SignComp 2121 Flat Bleed Retro Cover
White LED illumination
1 1/2” sq. aluminum tube with
0.090” thick aluminum sheeting
SignComp 2104 flat bleed retro
frame
Steel mounting structure from
2” sq. steel tubing (1/4” wall).
Cabinet mounted to tubing with
2” x 2” x 1/4” steel angle. Secured
with 1/2” dia. bolts
18"
6 1/4"
2 1/4"7/8"7/8"1"1"4 1/4"FLANGE PLATE LAYOUT
scale: 3”=1’03
1/4” thick steel plate welded to 2” x 2”
x 1/4” wall steel angle. Bolted to 2”
sq. tube (1/4” wall) in field
3/4” dia. holes for mounting anchors
Revise & resubmit
Approved
DESIGN STATUS:
BY:
DATE:
Sign Type: E1
Description: Rooftop Signage
Scale: Noted
Project: Merchants Bank
Date: 04/26/19 By: MW
* * *
Drawing Notes:
Construction View:
[P1] TBD
Standard Color
[P2] TBD
Standard Color
5349 W 86th Street • Indianapolis, IN 46268
317|872|8722
SignworksThinks.com
These drawings/and or the accompanying specications as instruments of service are
the exclusive property of Signworks, Inc. and their use and publication shall be restricted
to the original site for which they were prepared. Reuse reproductions or publications by any
method, in whole or part, is prohibited except by written authorization from Signworks, Inc.
Copyright and ownership of these plans and or specications shall remain with the designer
without prejudice and visual contact with them shall constitute Prima Fascia Evidence of
these restrictions. Signworks, Inc. shall be entitled to further compensation equal to
one hundred and fty (150%) of the original project fee, the total cost of production and
installation per occurrence, and the reasonable costs of collection for any unauthorized
use of these drawings and or specications or any derivative works thereof.
ROOF
ACCESS
HATCH
5
A353
R.D.
O.D.
R.D.
O.D.
R.D.
O.D.
ROOF PLAN VIEW