HomeMy WebLinkAbout06120061 As Built
~~.
Schn8ider
TIle _ CorporaUo.
61lO1 otiI A.....
IIIItoricrorl_.
IIld!allapolll. IIldlaDa 46216-1037
317-626-7100
317-626-7200 r.II
This Plot Plan Prepared For: Arbor Homes
Lot # 58 ,containing 12,591 S.F.:l:, in
The Trails at Hayden Run Sec. 1
iNSTR. # 200500069468
Ciay Twp, Hamilton Caunty
See 20, T29N, R3E
3245 WININGS LANE (50'R/W)
Westfield, IN 46074
PreiJ.are<LQaJec 12/01 /06 '- By. KAG
Community Restrictions:
Sid. YDrd =3' min.
Rear Yard = N(A
Aggregat. = 6 (B.H.)
ARBOR HOMES
Pad Grad. = 920.7 per plan
Pad Grade + 1.0' = Garage FFE (921.7)
Garage FFE + 0.5' = Residential FFE (922.2)
Residential FFE - 9.0' = Basement FFE (913.2 )
Driveway Slope = 5.1"
Note: The garage finished floor elevation
Is 1.9' above the curb at the drive, per
plan. ~
M.H.flI12
TC=92.66
PER RECORD
ORA'IlmG
GROUND COVER CALCULA 1l0NS:
Drive = 631 Sf:!:
Public Walk = 369 SF:!:
Private Walk = 77 Sf:!:
Seeding = 6,603Sf:!:
Sod = 3,283 SF:!: .
even with the rear of house.
~
~
Looda>ape Arch!tectlInl
GIll'US
GeoIoc'
Plot Plan Legend
I]li[[] Proposed Grades
000.0 Existing Grades
-000.0- Contour Grod.
* Appro~ Lateral Location
- . - Sanitary Sewer Unes
-Ir- Stann Sewer Unes
- 'W - Water Service Lines
- - - - - - - Sub-Surface Drain Unes
. Manhol. (Sanitary C)( Stonm)
. Beehive Inl.t (St()(m)
II1II Curb Inl.t (StDfm)
D - -End.Sectlon.(St()(m)--
..... Fire H)'Iront
- 000 _ 000 -Flow Une of swale
Note: Sanitary Sewer
Top of Casting Information
Upstream Manhole, TC= 920.66
Downstream Manhole, TC= 920.55
per plan.
Note:
The contractor is to maintain a
minimum distance of ten feet (10')
between the sonitry sewer and water
line laterals.
\I
· 94.00'
5.0' TC=919.50
ER PLAN PER PLAN
-I
NOTE:
SUMP PUMP(S) TO BE PLACED
BY BUILDER AS NEEDED.
Note:
The basement e1ewtlon, depicted hereon, ha:! been
detenniled mQ bcsed on the pad grades OOd/<< contours
token from the construction ploos for this aubdlYlsion.
Unless stated, no Information OOout fluctuating water
tables. soli conditions, or soil t~ has been prcMded or
stated an said plooa. this lot Is located near a body of
water. Lot or sol conditions may require that the bcsement
floor elevation be held 2 foot above normal pool elevation.
Site ilvestlgation may be needed If water Ia encountered
durilg the exccMJtion process or If other known water
elevation or sols conditions <n present Investigation and
any remedial procedures Is at the discretion of the buDder
to determine CIld toke appropriate steps at action. If any
CJ'ound water Is encountered during exoovotion the buJder
Is encouraged to contoc:t The Schneider Corporation to
discuss possible courses of action.
FLOOD HAZARD STATEMENT
CERTlFlCA TlON
,,\\1\1\\\\\1111111/1/////1.
~"\~c. L /'l ~ij~
# ~7........:.....~;f~:%
ff (:~,,"'G\S T~~i-"""'A~
"'c:2;',"Q;-"- No 0',.;<>",,-
, ( 50303 .\ ,
;;: ~ : .:;:
% \. STATE OF ..... ~
\ <';;>f.tvOI A\'l!:.....~f
~;:{f "S'UR~\~~
~1/III/I1/IIIIII\I\\\\\I\I~
O'-lf11
I
I
-+---
+-
I
I
1-
'"
1';-
I!=
I~
I
I
I
I
I
I
I
I
I
I
I
1
I
Note:
this drawing is based on construction plans or record drawings,
and is not based upon a field survey. The Schneider Corporation
does not warrant the accuracy or sufficiency of this Information.
Contractors should verify existing conditions prior to any
construction. Any dlsaepancy found on this drawing should
be reported to The Schneider Corporation Immediately; failing
to do so results In the contractors assumption of all lIabll1ty.
LOT # 58
VB # 06.0064225
D.taO of tlPlcaI St()(m
Water flow pattern for
IndMdual Jots.
~
~
=~=
'Wi
I I
I I
1 - '1
~
Assum.d NDfth
Scale : 1- = 30'
Note: BuDder to ensure
posltlve drainage away
frDfn structure(s).
26.0'
.
5' WAll<
WININGS LANE
5.0' 1
PER PLAN
1
I
I
I
1
I
I
I
I
1 1920.21
L____________
15' D.U.&S.E
'"
..,
'"
:,.
16.0' I
_I
'" I BASEIIENT
g 11:l MATTERHORN A
... ;I; FRM&lISY
~ 1 RESlOENCE
I
14.00'
0J
CD
0,
CD_
90.00'
R[',1SON 11
RE'<1S8l HOUSE PER FAX
VS06.0065596
12/07/06 - KAG
This drawing is not intended to be represented os a retrocement or
original boundary survey. 0 route survey, or 0 Surveyor Location Report.
Rood Hazard Statement: The accuracy of any flood haz(l'(j dota shown on this report
Is subject to map scale uncertanty and to any other unmanty n location or
elevation on the referenced flood Insurance rate map. All of the within described land
DOES NOT UE within that specld flood hazard zon. A as said land plots by scaI. on
flood insurance rat. mop , 1B057C0205F fC)( CIty of Carmd. indiana (mop. dated
Fobrucry 19, 2003).
EJ.rV..919.6
PER PLAN
APRON
.
16'
0Rl\{
25' B.L
~ 22.67 ~3.6
00 CAR
GARAGE
10.0'
4
~..,
p
....
,
0J
CD
CD
N_
66.9'
~.
:i
b
. ~. ~
TYPICAL $WALE SECTION
Note:
Per Conmd zoning Dfdlnane. 26.1.1 : Th. residential
district limits h.lght to twenty-fi", feet (25'), however
o dwelling may b. Increased In h.lght to thlrty-fi",
feet (35') provided th. side and rear )'OI'ds Dr, Increased
an additional on. foot (1') for eacl1 on. foot (1') the
.tructure exceeds th. first twenty-fi", feet (25') In
h.lghl