Loading...
HomeMy WebLinkAbout06120061 As Built ~~. Schn8ider TIle _ CorporaUo. 61lO1 otiI A..... IIIItoricrorl_. IIld!allapolll. IIldlaDa 46216-1037 317-626-7100 317-626-7200 r.II This Plot Plan Prepared For: Arbor Homes Lot # 58 ,containing 12,591 S.F.:l:, in The Trails at Hayden Run Sec. 1 iNSTR. # 200500069468 Ciay Twp, Hamilton Caunty See 20, T29N, R3E 3245 WININGS LANE (50'R/W) Westfield, IN 46074 PreiJ.are<LQaJec 12/01 /06 '- By. KAG Community Restrictions: Sid. YDrd =3' min. Rear Yard = N(A Aggregat. = 6 (B.H.) ARBOR HOMES Pad Grad. = 920.7 per plan Pad Grade + 1.0' = Garage FFE (921.7) Garage FFE + 0.5' = Residential FFE (922.2) Residential FFE - 9.0' = Basement FFE (913.2 ) Driveway Slope = 5.1" Note: The garage finished floor elevation Is 1.9' above the curb at the drive, per plan. ~ M.H.flI12 TC=92.66 PER RECORD ORA'IlmG GROUND COVER CALCULA 1l0NS: Drive = 631 Sf:!: Public Walk = 369 SF:!: Private Walk = 77 Sf:!: Seeding = 6,603Sf:!: Sod = 3,283 SF:!: . even with the rear of house. ~ ~ Looda>ape Arch!tectlInl GIll'US GeoIoc' Plot Plan Legend I]li[[] Proposed Grades 000.0 Existing Grades -000.0- Contour Grod. * Appro~ Lateral Location - . - Sanitary Sewer Unes -Ir- Stann Sewer Unes - 'W - Water Service Lines - - - - - - - Sub-Surface Drain Unes . Manhol. (Sanitary C)( Stonm) . Beehive Inl.t (St()(m) II1II Curb Inl.t (StDfm) D - -End.Sectlon.(St()(m)-- ..... Fire H)'Iront - 000 _ 000 -Flow Une of swale Note: Sanitary Sewer Top of Casting Information Upstream Manhole, TC= 920.66 Downstream Manhole, TC= 920.55 per plan. Note: The contractor is to maintain a minimum distance of ten feet (10') between the sonitry sewer and water line laterals. \I · 94.00' 5.0' TC=919.50 ER PLAN PER PLAN -I NOTE: SUMP PUMP(S) TO BE PLACED BY BUILDER AS NEEDED. Note: The basement e1ewtlon, depicted hereon, ha:! been detenniled mQ bcsed on the pad grades OOd/<< contours token from the construction ploos for this aubdlYlsion. Unless stated, no Information OOout fluctuating water tables. soli conditions, or soil t~ has been prcMded or stated an said plooa. this lot Is located near a body of water. Lot or sol conditions may require that the bcsement floor elevation be held 2 foot above normal pool elevation. Site ilvestlgation may be needed If water Ia encountered durilg the exccMJtion process or If other known water elevation or sols conditions <n present Investigation and any remedial procedures Is at the discretion of the buDder to determine CIld toke appropriate steps at action. If any CJ'ound water Is encountered during exoovotion the buJder Is encouraged to contoc:t The Schneider Corporation to discuss possible courses of action. FLOOD HAZARD STATEMENT CERTlFlCA TlON ,,\\1\1\\\\\1111111/1/////1. ~"\~c. L /'l ~ij~ # ~7........:.....~;f~:% ff (:~,,"'G\S T~~i-"""'A~ "'c:2;',"Q;-"- No 0',.;<>",,- , ( 50303 .\ , ;;: ~ : .:;: % \. STATE OF ..... ~ \ <';;>f.tvOI A\'l!:.....~f ~;:{f "S'UR~\~~ ~1/III/I1/IIIIII\I\\\\\I\I~ O'-lf11 I I -+--- +- I I 1- '" 1';- I!= I~ I I I I I I I I I I I 1 I Note: this drawing is based on construction plans or record drawings, and is not based upon a field survey. The Schneider Corporation does not warrant the accuracy or sufficiency of this Information. Contractors should verify existing conditions prior to any construction. Any dlsaepancy found on this drawing should be reported to The Schneider Corporation Immediately; failing to do so results In the contractors assumption of all lIabll1ty. LOT # 58 VB # 06.0064225 D.taO of tlPlcaI St()(m Water flow pattern for IndMdual Jots. ~ ~ =~= 'Wi I I I I 1 - '1 ~ Assum.d NDfth Scale : 1- = 30' Note: BuDder to ensure posltlve drainage away frDfn structure(s). 26.0' . 5' WAll< WININGS LANE 5.0' 1 PER PLAN 1 I I I 1 I I I I 1 1920.21 L____________ 15' D.U.&S.E '" .., '" :,. 16.0' I _I '" I BASEIIENT g 11:l MATTERHORN A ... ;I; FRM&lISY ~ 1 RESlOENCE I 14.00' 0J CD 0, CD_ 90.00' R[',1SON 11 RE'<1S8l HOUSE PER FAX VS06.0065596 12/07/06 - KAG This drawing is not intended to be represented os a retrocement or original boundary survey. 0 route survey, or 0 Surveyor Location Report. Rood Hazard Statement: The accuracy of any flood haz(l'(j dota shown on this report Is subject to map scale uncertanty and to any other unmanty n location or elevation on the referenced flood Insurance rate map. All of the within described land DOES NOT UE within that specld flood hazard zon. A as said land plots by scaI. on flood insurance rat. mop , 1B057C0205F fC)( CIty of Carmd. indiana (mop. dated Fobrucry 19, 2003). EJ.rV..919.6 PER PLAN APRON . 16' 0Rl\{ 25' B.L ~ 22.67 ~3.6 00 CAR GARAGE 10.0' 4 ~.., p .... , 0J CD CD N_ 66.9' ~. :i b . ~. ~ TYPICAL $WALE SECTION Note: Per Conmd zoning Dfdlnane. 26.1.1 : Th. residential district limits h.lght to twenty-fi", feet (25'), however o dwelling may b. Increased In h.lght to thlrty-fi", feet (35') provided th. side and rear )'OI'ds Dr, Increased an additional on. foot (1') for eacl1 on. foot (1') the .tructure exceeds th. first twenty-fi", feet (25') In h.lghl