HomeMy WebLinkAbout080923_11715_River_Rd_Carmel_TRUSS_CDs_Sheet_2_of_5_REVISED.pdf55'-3 1/2" V.I.F.
#1 or Better SYP
2x10 Rafters
@ 24" O.C. 21'-3 1/4" V.I.F.
4'-0"
2'-8" O/H
2'-8" O/H
1'-4" O/H
2x10 Ledger Anchor Bolt to
Masonry
8'-0"
16" Hip Truss with (2) 2x10 Hip Lookouts
Sistered to Each Side - Typical at Main
Roof
2x10 Lookout Rafters
@ 24" O.C. 17'-5 1/2"
27'-1 1/2" V.I.F.
Nominal 24x48 Skylight Opening,
Typical of (4)
EQ EQ
1'-3"
EQ 4'-0" 4'-0" EQ
2x10 Subfascia - Typical
4'-7" V.I.F.
1'-4" O/H
(2) 2x10 Hip Rafters
16" Open Web Wood Trusses @ 24" O.C.
General Notes:
1. 2x10 Garage Rafters to be #1 or Better
SYP as Noted.
2. 2x10 Subfascias, Lookouts and
Ledgers to be #2 or Better SYP.
2x10 Lookout Rafters - Sister to
Trusses - Typical
8'-0"
72" 24" 24" 24" EQEQ 24" 24" 24" 72"
32" O/H 21'-9 1/2" V.I.F. 32" O/H
24"
72" 24"
72"
Dimensions Same on Both Sides
Exterior Improvements
Jovanovich Residence | 11715 River Road | Carmel, Indiana
Scale: As Noted | July 13, 2023 | Sheet 2 of 5
Michael E. Brannan / Architect LLC | (317 702-0396 | mbrannan.arch@gmail.com
C 2023 Michael E. Brannan Architect / LLC All Rights Reserved
Beam & Bearing Plan
Scale: 1/8" = 1'-0"
North
A
C
C
A
Roof Framing Plan
Scale: 1/8" = 1'-0"
North
A
C
C
A
B B B B
D D
D D
(2) 1.75x11.875 1.9E LVL w/ (3)
Jacks per Side
Existing Bearing Wall
Existing Bearing Wall
Extend Bearing Wall with 2x4
Framing @ 16" O.C.
Extend Bearing Walls with 2x4
Framing @ 16" O.C.
Extend Bearing Wall with 2x4
Framing @ 16" O.C.
Note: Extend Non-Bearing Interior
Partitions where Required (not shown) with
2x4 Framing @ 16" O.C. Finish to Match
Adjacent.
Extend Bearing Wall with 2x4
Framing @ 16" O.C.
Extend Bearing Wall
with 2x4 Framing @
16" O.C.
Enclose Exterior Wall to
Match Adjacent
Enclose Exterior Wall to Match
Adjacent
Enclose Exterior Wall to Match
Adjacent
Outline of Wall Below Typical
1 1
1 08/09/23 Added Notes and Dimensions