HomeMy WebLinkAbout06120082 Site Plan BUCKINGHAM - ELEV 4C LEFT HAND - Brick 3 Sides FULL BSMT - 9' Walls 3 CAR - Side Entry Gar. FFE = 767.0 1st Fir FFE = 766.6 TOW = 767.6 Bsm! FFE = 759.0 Drive Slope =: 2.2% ' Note: ContractorllhouldvBrlfysllBspecinc Information daplcledhereOflwllh the ilpprovedcanslrucllonplanslorthla dllvelapmenl.Also,Contraclorshauld flllarenca ArchltBchllBI plans for fOlJndationorlenlalion and dlmenl>ians. Not.; Minimum Fronl yard.25' lnlmum Side Yard-3' nimumAggragala-6' etweoo Houses) \nlmum Rear Yard - NlA ,%@(;)l!IJlliJj)@@] [}!]@1l'1I1lu O@8 iJ" = ~@' c;ffi "0 '1''''1.. ~{)?'1 .~ l&X:PJ '" Proposed Grade _.. Drainage Flow XX.X .. Existing Grade IJZOlVe C..q,s€, el? LO ~. ~..o.."" ~O^'I2. 1794,q ~e:--"':':"" Cone Flatwork Sq. Ft = :t1563 Public Walk Sq Ft = :i:382 Sod Sq Yds = .31 9 Seeding Sq Fl = <7503 Flood HHard Noto: Lol Number 173 1l9a partially within that Special Flood Hazard Zone 'AE' and Zone 'X" (shaded) per ravlsed localion on the Flood Insurance Ralll Maps lor Hamilton County, Indiana (Community Penel #18057C0235F, deted Fabl1.lary 19, 2003), LOMR, CaseM05-05-1194A, da16d January 27, 2005, B.f,E. =761.5 Note; The proposlldCllnstrucllon gredas, contours, and proposed structure elevations aa deplctad hereon are based l.Ipon \nfoonatlon provided upon lhe approved cOlllltl1.lCUOn documants prepered for this development. Unless othelWlslllllated hereon, no Information pertaining to but not limited to, lluctuatlng weter tables elevations, soli types, and conditions wlthln the building ereas of this development have been provldad and \or referenced on said documents. Withlheexcevallonoflhllproposedlltructufa foundllUons, Ollrtllln care andobservelions should be made In regard to such condlllons as solltypall and nuctuatlng wuler tables. Ourlng the excevaUonprocBssshould any uflsultablesolIs or ground wlllBf be wltnesllee!, the butle!er shall be immadlately notified for further llxemlnation and consuttatiOll. AI the builders dlSCfetlon, additional conslNcllon techniques may be neCllssary to altelllate IUU.lfe problems. Nole: ThlsdrBwlng ls based upon COflstructlon plans Bndlorracore! drewlngs prepated by others end Is not basad upon efleldsurvay. COOR Consulting /I, Lane! Services, COlp. does not werrant lhe correctness or Integrity of this \nformatlon. The contractor/owner should lIerify exlsUng condlllons prior to construction. Any ....arylr.g Iield conditions or any dlscrapancy wHh Ihe InlormaUon contained hereon should be Immediately reported 10 COOR Consulting & Land Services, Corp.: failure to co so would resull in the contractor/cwnels essumpllonof \lBbltlty. ~oorc @@Il\J~Qj)D\loll\J\ID I%lt DIIDIl\J@] ~@[j'\YJO@@@~ @ @ Il' [j!l @ Il' lID 11 0 @ IJi] 303 WEST MAIN STREET KNIGHTSTOWN. INDIANA (888) 593-2667 (765)345-5943 FAX#: (765}345-5692 DATE: 12115/06 JOB #2003-100.173 REVISIONS; 1 @[}{Irn~~Y1 @~rnrn~ rn~LrI.i\Lrrn~ \O!ii@'iIII@I)!]<) INSTR. #200500009933 PC 3, SLIDE 580 C.O.C. #200500011991 PLOT PLAN Prepared For: (~J LOT # 173 13970 SAlMON DRIVE CARMEL, IN 46033 Pulte Homes of Indiana