HomeMy WebLinkAboutA105 - UPPER LEVEL FLOOR PLANSARCHITECTURAL PLAN NOTES
(ALL NOTES MAY NOT BE INDICATED ON THIS SHEET)
INDICATES WALL TYPE. REFER TO
DRAWING A1.06 FOR WALL THICKNESS,
HEIGHT AND COMPOSITION.
ARCHITECTURAL PLAN GENERAL NOTES
A. ALL CMU WALLS THAT DO NOT LAY OUT IN FULL OR
HALF LENGTHS SHOULD BE BALANCED SO AS NOT
TO HAVE ANY PIECES LESS THAN 4" IN SIZE EXPOSED
TO VIEW.
B. WHERE DISSIMILAR FLOOR MATERIALS MEET, THEY
SHALL DO SO UNDER THE CENTERLINE OF THE DOOR,
UNLESS NOTED OTHERWISE.
C. THERE SHALL BE PERIMETER INSULATION CONTINUOUS
AROUND THE ENTIRE PERIMETER OF THE BUILDING
EXTENDING 2'-0" MINIMUM BELOW GRADE.
D. THE BASE FLOOR ELEVATION INDICATED FOR THE
PROJECT IS 100'-0". REFER TO SITE PLAN FOR
CORRELATION TO USGS DATUM.
E. ALL INTERIOR MASONRY WALLS THAT RUN TO
UNDERSIDE OF DECK ABOVE SHALL HAVE A 2" JOINT
(U.N.O.) AT THE DECK TO BE FILLED WITH FIRE
STOPPING AT RATED WALLS PER PROJECT MANUAL.,
AND MINERAL WOOL AT THE NON-RATED WALLS, TO
ALLOW FOR DEFLECTION.
F. FOR TYPICAL COMMON JOINT DETAILS AND
CONSTRUCTION MOVEMENT JOINT DETAILS REFER TO
DETAILS ON SHEET XX.
G. ALL DIMENSIONS ON FLOOR PLANS ARE TO FINISH
FACE OF CMU, CONCRETE, BRICK OR FINISH FACE OF
GWB AT METAL STUD WALLS, UNLESS NOTED
OTHERWISE. EXCEPTION: EXTERIOR METAL STUD
WALLS ARE TO FACE OF METAL STUDS.
H. HINGE SIDE DOOR JAMB AT WALLS WILL TYPICALLY BE
LOCATED 4" MINIMUM FROM ADJACENT WALL UNLESS
NOTED OTHERWISE.
I. ALL EXPOSED CONCRETE MASONRY UNITS (CMU)
CORNERS ARE TO BE BULLNOSE, EXCEPT AT WINDOW
JAMBS, BULKHEADS, WINDOW AND DOOR HEADS.
J. SEE REFLECTED CEILING PLANS FOR BULKHEAD
LOCATIONS AND DETAIL REFERENCES.
K. REFER TO ROOM FINISH SCHEDULE OR PLAN AND
EQUIPMENT PLANS FOR LOCATION AND EXTENT OF
FINISH FLOOR MATERIALS.
L. PROVIDE WOOD BLOCKING AS REQUIRED. WITHIN
METAL STUD WALLS FOR WALL MOUNTED ITEMS.
M. REFER TO MASTER/CODE PLANS FOR CODE
INFORMATION AND FIRE RATED WALL LOCATIONS.
N. PROVIDE SPRAY FOAM INSULATION AND THERMAL
BARRIER CONTINUOUS AT INTERSECTION OF EXTERIOR
WALLS AND DECK.
VERIFICATION NOTE
CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND
CLEARANCES AND ALL EXISTING FIELD CONDITIONS
BEFORE STARTING CONSTRUCTION. COMMENCEMENT
OF WORK CONSTITUTES ACCEPTANCE OF CONDITIONS.
SHOULD DIFFERENT CONDITIONS BE ENCOUNTERED,
CONTACT THE ARCHITECT BEFORE PROCEEDING WITH
WORK.
X
W###
A
A4.01
B
A4.01
2
A5.02
1
A5.01
C
A4.01
B201
B7
1
A5.02
3
A5.01
B6
3
A5.02
4
A5.04
D
A4.01
1
A5.03
2
A5.03
23-H
23-F
23-E
23-D
23-Cc
23-Cb
23-C
23-B
B5B4B2
1
A5.05
2
A5.05
3
A5.05
4
A5.05
23-Cd
23-Ca
A3.02
4
W16
W16
W16
ROOF BELOW
ROOF BELOW
5
A5.08
B3
A11
A18
B201A
3
A2.02
A3.03 5
A3.0344
A5.08
32'-7"30'-0"6'-3"7 1/4"16'-5"7 1/4"6'-1 1/2"7 1/4"7'-10 5/8"3'-4"10'-0"6
A5.08
6
A5.04
NEW BULKHEADS WITH SLOPED TOP TO
MATCH EXISTING
1
A5.07
2
A5.07
5
A7.07
A10
A12
A16
A12
A12
A12
A12
A12
A12
A12
A12
A12
6
A5.07
N
WS ECOPYRIGHT 2023 BY FANNING/HOWEY ASSOCIATES, INC.
KEY PLAN
A
B
CD
WWW.FHAI.COM
ARCHITECT
12/13/2023 5:30:34 PMC:\Users\tvaughn\Documents\2021_ARCH_222011.00_tpvaughn.rvtPROJECT NUMBER: 222011.00
CHERRY TREE
ELEMENTARY
SCHOOL
ADDITIONS AND
RENOVATIONS
13989 Hazel Dell Pkwy, Carmel, IN
46033
UPPER LEVEL FLOOR PLANS
A1.05
PROJECT ISSUE DATE: 12.15.2023
BIDS
DRAWN BY: TPV
317-848-0966
350 E. NEW YORK ST, INDIANAPOLIS IN 46204
PROJECT MANAGER: SAM
CARMEL CLAY SCHOOLS
SCALE: 1/8" = 1'-0"
UPPER LEVEL UNIT B PLAN
SCALE: 1/8" = 1'-0"
UPPER LEVEL UNIT C PLAN
REV.