HomeMy WebLinkAboutA303 - BUILDING ELEVATIONSFIRST FLOOR EL 100'-0" 1 A5.08 EL. 112'-8" EL. 107'-8" EL. 101'-4" HOLLOW METAL / FRP / WOOD DOOR -REFER TO DOOR SCHEDULE METAL COPING AND WOOD NAILER 2" WATER-DRAINAGE-EXTERIOR INSULATION AND FINISH SYSTEM (EIFS) MODULAR SIZE FACE BRICK -COLOR A OVERHEAD COILING SERVICE DOOR ELECTRICAL LIGHT FIXTURE -REFER TO ELEC. DRAWINGS. TECHNOLOGY EQUIPMENT -REFER TO TECHNOLOGY DRAWINGS. FIRST FLOOR EL 100'-0" 3 A5.08 METAL COPING AND WOOD NAILER 2" WATER-DRAINAGE-EXTERIOR INSULATION AND FINISH SYSTEM (EIFS) MODULAR SIZE FACE BRICK -COLOR A CAST-IN-PLACE CONCRETE -REFER TO STRUCTURAL DRAWINGS ELECTRICAL LIGHT FIXTURE -REFER TO ELEC. DRAWINGS. METAL GUTTER EXISTING BUILDING EL. 112'-8" EL. 107'-8" EL. 101'-4" ELECTRICAL LIGHT FIXTURE -REFER TO ELEC. DRAWINGS. FIRST FLOOR EL 100'-0" 2 A5.08 METAL COPING AND WOOD NAILER 2" WATER-DRAINAGE-EXTERIOR INSULATION AND FINISH SYSTEM (EIFS) MODULAR SIZE FACE BRICK -COLOR A CAST-IN-PLACE CONCRETE -REFER TO STRUCTURAL DRAWINGS ELECTRICAL LIGHT FIXTURE -REFER TO ELEC. DRAWINGS. TECHNOLOGY EQUIPMENT -REFER TO TECHNOLOGY DRAWINGS. CAST-IN-PLACE CONCRETE -REFER TO STRUCTURAL DRAWINGS EL. 107'-8" EL. 112'-8" EXISTING BUILDING METAL GUTTER EL. 101'-4" C A4.01 23-D23-Cc23-Cb23-C 4 A5.05 23-Cd23-Ca EL. 114'-8" T./FLASHING MANUFACTURED ROOF EDGE FASCIA 2" WATER-DRAINAGE-EXTERIOR INSULATION AND FINISH SYSTEM (EIFS) METAL GUTTER 4" X 5" METAL DOWNSPOUT TO ROOF BELOW, PROVIDE PROTECTION SHEET AT DISCHARGE METAL REGLET AND COUNTERFLASHING 1 1/2" / 12" C A4.01 23-D 23-Cc 23-Cb 23-C 1 A5.05 2 A5.05 23-Cd 23-Ca EL. 114'-8" 1 1/2" / 12"1 1 /2 " / 1 2 " METAL GUTTER T./FLASHING 4" X 5" METAL DOWNSPOUT TO ROOF BELOW, PROVIDE PROTECTION SHEET AT DISCHARGE MANUFACTURED ROOF EDGE FASCIA 2" WATER-DRAINAGE-EXTERIOR INSULATION AND FINISH SYSTEM (EIFS) METAL REGLET AND COUNTERFLASHING 4 A5.08 MECHANICAL LOUVER (MFR. PAINTED CUSTOM COLOR SELECTED BY ARCHITECT) -REFER TO MECH. DRAWINGS. ELECTRICAL EQUIPMENT -REFER TO ELEC. DRAWINGS. MECHANICAL EQUIPMENT -REFER TO MECH. DRAWINGS. HOLLOW METAL / FRP / WOOD DOOR -REFER TO DOOR SCHEDULE ELECTRICAL EQUIPMENT -REFER TO ELEC. DRAWINGS. VERIFICATION NOTE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CLEARANCES AND ALL EXISTING FIELD CONDITIONS BEFORE STARTING CONSTRUCTION. COMMENCEMENT OF WORK CONSTITUTES ACCEPTANCE OF CONDITIONS. SHOULD DIFFERENT CONDITIONS BE ENCOUNTERED, CONTACT THE ARCHITECT BEFORE PROCEEDING WITH WORK. ELEVATION GENERAL NOTES 1. REFER TO THE ELECTRICAL AND TECHNOLOGY DRAWINGS FOR CAMERA, LOCATIONS, SECURITY DEVICES, RECEPTACLES, LIGHT FIXTURES, ETC. COORDINATE LOCATIONS WITH VENEER COURSING TO PROVIDE CONSISTENT MOUNTING HEIGHTS. 2. REFER TO PLUMBING DRAWINGS FOR EXTERIOR WALL HYDRANTS, SECONDARY ROOF DRAIN OUTLETS, ETC. COORDINATE PENETRATIONS THROUGH EXTERIOR ENVELOPE WITH OTHER TRADES. PROVIDE TRANSITION MEMBRANE TO MAINTAIN AIR BARRIER SYSTEM. 3. REFER TO MECHANICAL DRAWINGS FOR EXTERIOR LOUVER LOCATIONS LOCATED IN EXTERIOR WALL AND EXTERIOR SOFFITS. COORDINATE PENETRATIONS THROUGH EXTERIOR ENVELOPE WITH OTHER TRADES. PROVIDE TRANSITION MEMBRANE TO MAINTAIN AIR BARRIER SYSTEM. 4. REMOVE EXISTING GUTTERS, DOWNSPOUTS, AND CAST IRON D.S. BOOTS FOR THE ENTIRE PROJECT. PROVIDE NEW GUTTERS, DOWNSPOUTS AND CAST IRON DOWNSPOUT BOOTS IN SAME LOCATION AS EXISTING. ALIGN NEW CAST IRON D.S. BOOTS WITH EXISTING UNDERGROUND STORM PIPING. FIELD VERIFY EXISTING STORM PIPING SIZES TO MATE WITH NEW BOOTS. 5. REFER TO FLOOR PLANS AND EXTERIOR ELEVATIONS FOR NEW BUILDING ADDITION. 6. PROVIDE PROTECTION SHEET AT LOCATIONS WHERE DOWNSPOUTS EMPTY ONTO LOW SLOPE ROOF. 7. PROVIDE ELBOWS AT BASE OF DOWNSPOUTS WHERE THEY EMPTY ONTO LOWER SLOPED ROOF. 8. PROVIDE OFFSET AT BASE OF D.S. WHERE MASONRY EXTENDS PAST FACE OF WALL ABOVE. 9. CLEAN FULL PERIMETER AND HEIGHT OF EXTERIOR VENEER MASONRY INCLUDING THE MASONRY SCREEN WALL NEAR MECHANICAL EQUIPMENT AREA. 10. CLEAN FULL EXTENTS AND HEIGHT OF EXISTING EXTERIOR EIFS MATERIAL. 11. REPAIR EXISTING DAMAGED EXTERIOR EIFS. REFER TO ELEVATIONS. PROVIDE NEW EIFS ELASTOMERIC COATING OVER FULL EXTENTS AND HEIGHT OF EXISTING EIFS SURFACES TO REMAIN. 12. PROVIDE GUTTER EXPANSION JOINTS WHEN LENGTH OF GUTTER EXCEEDS 40 FEET. REFER TO DETAIL. 13. PROVIDE CORNER SPLASH GUARDS AT ALL VALLEY LOCATIONS - REFER TO DETAIL. EXTERIOR ELEVATION NOTES X COPYRIGHT 2023 BY FANNING/HOWEY ASSOCIATES, INC. WWW.FHAI.COM ARCHITECT 12/13/2023 5:17:55 PMC:\Users\tvaughn\Documents\2021_ARCH_222011.00_tpvaughn.rvtPROJECT NUMBER: 222011.00 CHERRY TREE ELEMENTARY SCHOOL ADDITIONS AND RENOVATIONS 13989 Hazel Dell Pkwy, Carmel, IN 46033 BUILDING ELEVATIONS A3.03 PROJECT ISSUE DATE: 12.15.2023 BIDS DRAWN BY: TPV 317-848-0966 350 E. NEW YORK ST, INDIANAPOLIS IN 46204 PROJECT MANAGER: SAM CARMEL CLAY SCHOOLS SCALE: 1/4" = 1'-0" NORTH ELEVATION - OUTDOOR STORAGE1 SCALE: 1/4" = 1'-0" EAST ELEVATION - OUTDOOR STORAGE2 SCALE: 1/4" = 1'-0" WEST ELEVATION - OUTDOOR STORAGE3 SCALE: 1/4" = 1'-0" EAST ELEVATION - MEZZANINE4 SCALE: 1/4" = 1'-0" WEST ELEVATION - MEZZANINE5 REV. NO.DESCRIPTION DATE