HomeMy WebLinkAboutA010.10 Solar Canopy Preliminary Engineering DrawingSHEET NOTES a. FOR STRUCTURE LOCATIONS REFERENCE PROJECT SITE PLAN. COLUMN SPACING AND LOCATIONS SHALL BE COORDINATED WITH PROJECT ARCHITECT OR PROFESSIONAL RESPONSIBLE FOR SITE PLAN. b. VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION. DIMENSIONS, ELEVATIONS WHERE SHOWN ARE TO BE USED AS AN AID AND SHALL BE COORDINATED WITH THE GENERAL CONTRACTOR PRIOR TO CONSTRUCTION. c. FOR ADDITIONAL INFORMATION, REFERENCE GENERAL STRUCTURAL NOTES. PV PANEL INFORMATION A. CONTRACTOR TO VERIFY PANEL INFORMATION PRIOR TO FABRICATION AND ERECTION. B. THE PANEL INFORMATION BELOW AND IN THE PLANS WAS PROVIDED BY THE OWNER DURING THE DESIGN PHASE AND PRIOR TO THE START OF CONSTRUCTION. ALL PANEL INFORMATION INDICATED IN THESE DRAWINGS IS FOR REFERENCE ONLY AND SHALL BE VERIFIED WITH THE OWNER, THE ELECTRICAL DRAWINGS AND THE GENERAL CONTRACTOR PRIOR TO FABRICATION AND PRIOR TO CONSTRUCTION. C. THE OWNER IS TO PROVIDE A PANEL CAPABLE OF SUPPORTING IN MANOR IN WHICH IS INTENDED BY THESE DRAWINGS (I.E. SUPPORTED BY SHORT END, DUAL SUPPORTS, ETC). SUBMIT PANEL SPEC SHEETS FOR REVIEW PRIOR TO PURCHASING ANY PANELS. D. THE PANEL MANUFACTURER IS RESPONSIBLE FOR THE DESIGN OF THE PANELS INCLUDING ALL IT'S COMPONENTS. PHOTOVOLTAIC PANELS AND IT'S COMPONENTS SHALL BE DESIGNED TO SUPPORT PANEL WEIGHT PLUS SNOW, WIND, OR SEISMIC LOADING, WHICHEVER COMBINATION PRODUCES THE MOST SEVERE CONDITION IN ACCORDANCE WITH THE BUILDING CODE 6T 1 2 12' - 6" MAX 27' - 0" MAX EQ EQ TYP EQ TYP 6' - 0" TYP EQ 6 4 310 S4.1 10 S4.1 2 S2.6 27'-0" MAX 2W7 5 5 12 S4.1 SLOPE DOWN 5°W WW W14X38W14X387 FOUNDATION PLAN 0' -0" BOTTOM OF FOOTING -12' -0" BOTTOM OF COLUMN -4' -0" 6T 24' - 7 3/4" S4.1 2 S4.1 11 S4.1 11 S4.1 5 6 S4.1 1 9 7 SLOPE 5° 19 1/8" 58 5/8" 38 13/16"58 5/8" 38 13/16"58 5/8" 19 1/8" W 6" 1 9 1 /8 " 5 8 5 /8 "3 8 1 3 /1 6 "5 8 5 /8 "3 8 1 3 /1 6 "5 8 5 /8 "1 9 1 /8 "2 4 ' - 7 7 /8 "9' - 0" CLEARS L O P E 5 ° 88 BOTTOM OF FOOTNG 2 -10' -6"SHEET NAME PROJECT NUMBER: DRAWN BY: CHECKED BY: DATE:2058 S. Dobson Rd. Suite 10Mesa, AZ 85202(480) 454-6408www.unitedstr.comS2.6 6 PANEL STRUCTURE PLANS 23375 KS JE 08/28/2023USD #:23375KEYNOTES 1DRILLED CONCRETE POLE FOOTING. FOR DIAMETER AND EMBEDMENT OF FOOTING SEE FOUNDATION PLAN AND SECTION ON THIS SHEET. SEE DETAIL 2/S4.1 FOR REINFORCING AND STEEL COLUMN ANCHORAGE. 2C10"x3"x14 GAUGE COLD FORMED STEEL PURLINS, TYPICAL. COORDINATE EXACT LOCATION WITH SOLAR PANEL MANUFACTURER SPECIFICATIONS. SEE DETAIL 9/S4.1 FOR MORE INFORMATION ON SECTION. 3SAG ROD AS SHOWN ON PLANS, (1) MINIMUM AT SPANS LESS THAN 18'-0" AND (2) MINIMUM AT SPANS LESS THAN 27'-0". REFERENCE DETAIL 10/S4.1. 4(1) SAG ROD REQUIRED BETWEEN SUPPORT AND CANTILEVER END AS SHOWN. REFERENCE DETAIL 10/S4.1. SAG ROD NOT REQUIRED WHERE CANTILEVER IS LESS THAN 5'-0". 5DO NOT SPLICE PURLINS AT SUPPORT AT CANTILEVER ENDS. 616 GAUGE END CAP WITH 2" LEGS EACH END OF STRUCTURE. 7BEAM FLANGE BRACES AS SHOWN ON PLANS. REFERENCE DETAIL 6/S4.1 FOR MORE INFORMATION. 8PV MODULE BY OTHERS. ATTACH PER DETAILS. 9FINISHED GRADE. FINISHED GRADE IS DEFINED AS THE LOWEST ADJACENT FINISHED GRADE WITHIN 5 FEET OF THE STRUCTURAL COLUMN. PANEL MODEL LENGTH WIDTH Q.PEAK DUO XL-G11S 96.93" 44.65" 3/16" = 1'-0"1 6 PANEL Y - FRAMING PLAN 1/4" = 1'-0"2 6 PANEL 5 DEG Y SECTION NO SCALE36 PANEL Y - 5 DEG No. Description Date