HomeMy WebLinkAbout07010037 Site Plan
~~
Schn8ider
lb. 8clmeider CorporaUon
8801 QUa AMnII
_ '01\_
IIldlaDapelle, IDdlue 41218-1037
317-1128-7100
317-l12ll-72OIl 'AX
IqlDftrill&
SurftJIIIc
Wldape -
GIS.US
Geol'IJ
This Plot P1111 PrepcrecI For: 11ft Homes
Lot # 47, containing10,799 SF:!:, in
Heath.. Knoll
Section , 1
Instrument , 2OO5OOOOJ045
P.c. 3, Slide 560
Ooy Townahip. Homltlll County
SEe 20. TIllN. R03E
14361 CAMDEN LANE
Westfield, IN 46074
Prepared Dote: 04/11/06 : By. KAG_
Community Restrictions:
Side Yard == 3' min.
Aggregate = 6' 8.H.
Zoning - SI
M/I Homes
finished floor EI....lion Informalion
Pod Grode = 919.8 p'" plan
Pod Grode + 0.2' = Corage ffE (920.0)
Garage ffE + 0.5' = Residential ffE (920.5)
Residence ffE - 9.0' = 8asement ffE (911.5)
ORIVEWA Y SLOPE - 3.9ll:
GROOND COVER CAlCULA liONS:
Dri.. = 870 Sf i
Public Walk = 319 Sf:!:
Pri..te Walk =N/A Sfi
Seeding =5,756 Sfi
Sod = 210 SYi,
from fronl of residence.
T
Note:
This drawing is based on construction pions or record drawings.
and is nal based upon 0 field sur..y. The Schneid... Corporalion
does not .arrant Ihe accuracy or sufficiency of Ihis infarmalion.
Contractors should ..rify existing conditions prior 10 any
construction. Any discrepancy found on this dra.ing should be
reported to The Schneid... Corporation immediately, faBing to do
so results in the controctors assumption of all liobHity.
Plot Plan legend
(]M[] Proposed Grades
000.0 Existing Grades
___000.0- Contour Grode
* Apprax. Laleral localion
- . - Sanitary Se.... Unes
- If- Storm Se.... Unes
- " - Wal... Ser/ice lines
- - - - - - - Sub-Surface Drain Lines
. Manhole (Sanitary or Storm)
. 8eehive Inlet (Storm)
.. l1li - -Curn Inlel (Storm)
D End Section (Storm)
... fire Hydrant
- ..00 _ "00 -Flow Line of swole
- 8unding Une (8l / BSl)
- - - - - - - Easement Une
VB06.0052050
LOT. 47
o
~
=~=
o
Assumed North
Scale: I" = 30'
(50' RfW')
Detol of
Cround/Slonn Water:
now pattern of (II
ildMclual 101.
~
-M~
~~-
-- - -
I
Note: Build... to
ensure positive
drainage away
from structure(s).
Note: The controdor is to mointoin 0
minimum distonce of ten feet (10')
between the sanitory sewer ond water
line loterols.
Note: Sanitary Se.er
Top of Costing Information
Upstream Manhole, TC= 919. 76
Downstream Manhole, TC= 916.39
per record drawing.
NOlE: GARAGE fJ.[ IS
PROPOSED TO BE 1.4' ABO
CURB AT DRIVEWAY I8.M.
lA.H.pl1
TC=919.76
PER RECORD
DRA"MNG
,
I
I
Z
':i
.
o
I
TYPICAL SWALE SECTION
'-
CAI3
VAR. D.U.&S.5.[&
920.0 l.M.A.U 135.00'
P.P.A.[
10.0
---------,
~J3'
It I
J
W '"
z: ~ 00
<C
-.J 0
0
z: 0
, W ~il !
0 , I ...
~
~ ;;; I
~
<C I
U I
I
It I
lA.H.pl0 ~:
TC=916.39 m: 918.5
PER RECORD
DRAWING 30.0'
.
FLOOD HAZARD STATEMENT
CERTlFICA TlON
~\\\\\\\\\11III1I111/1/1111.
#"~ ~ L C, Vij~
~ ~ '\ ........... ~/~'~
~ ~".....\s TEl.....v.. ~
~ t..~..'-G 'Te"'. "A~
~~'i,,''q..'' No <,....~~
&~... . ". s:?-
I ( 50303 ) J
% .... STATE OF l ~
~ /.... .... ~
"" ~.of,;., /.. .. ~.' <:\ "
~ '4'J....:~Ofl''7.....~('..,....~
~ V)) ......... \..~ ~
?;>, U SUR'\ ~
~h/, , ~\~
VIJ""IIIIiIIIII\\\\\\\\'~
~l'F-fI
This drawing is not intenCJed to be represented os 0 retrocement or
original boundary survey. a route survey, or 0 Surveyor Localion Report.
flood Hazard Statement: The accuracy of any flood hazard data shown on this plot
plan is subject to mop scale uncertainty and to ony other uncertainty in location or
ele..tion on the ref...enced flood insurance rote mop (flRM). None of the .ithin
described land lies .ithin that special flood hazard zone "A", os soid land plots by
scale an Community Mop Panel I 18057C 0205f of the flood insurance rote mops
(flRM) for Hamilton County, Indiana, Doted May 19. 1981.
REVISION #1
NEW HOUSE MODEl.
VB06.0065753
12/12/06. KAG
I
~
m~~
~i~
>
2~00'
135,00'
<.0
(Jl
<.0
~
!=Xl
(Xl
I
I
~~I
!=XlI
(Xl
:f
,J
lS -
."l
:Or
!:>;r:: I
r" ...
r"
I
00
o
. I
o
o
i
,
,
Note: Sump pump(s) to be
NotE placed by build... os needed.
The bosement elevation, depicted hereon. hos been determi'led ond based on
the pod 170des ottd/<< contours tc*1rl from the constrvdion p1C11S fOf this
!Ubdhisian. Unless staled. no Information about lIuctuoti'lg water tables. sol
conditions, Of sol t)1)D has been prcMded Of stated on said pooa. this lot
is locoted near 0 bod)' of water. lot Of sol conditions mo)' requi'e that the
basement ftoor elevation be held 2 foot CII:Iclw normal pool 88'<<1tion. Site
Investigotion mOl be needed If ft.t.. is encountered lNrlruJ the t'ltGWtil:rl
process Of if other known water sewtion Of sois CClf'lditions ere p'esent.
Investigation ond aI)' remediol proc:eckwes is at the discretion of the. builder
to determine ond toke opprOClriote steps of oction. If alY 170und wat. is
encountered liIri'lg extO\lOtion the builder is encouroged to contoct The
Sdmeider Corporation to cflSCUSS possIlfe eouraes of oction.
NOTE:
IN THE RESIDENTIAL DISTRICTS LIMITING
HEIGHT TO TWENTY-FIVE (25) FEET. A
DWELLING MAY BE INCREASED IN HEIGHT
TO THIRTY-FIVE (35) FEET PROVIDED
THE SIDE AND REAR YARDS ARE
INCREASED AN ADDITIONAL FOOT FOR
EACH FOOT SUCH STRUCTURE EXCEEDS
TWENTY-FIVE (25) FEET IN HEIGHT.
PER CARMEL ZONING ORDINANCE 26.1.1.