Loading...
HomeMy WebLinkAboutLighting Info PERIMASHIELD™ . Sharp Cutoff optical system eliminates glare and light trespass . Field adjustable aiming allows for customized illumination . Wall or pole mount The Perimashield luminaire is ideal for exterior lighting applications where sharp cutoff is required. This versatile luminaire features adjustable cutoff from 70" to 90" to prevent light trespass or glare. This luminaire is perfectly suited for commercial and industrial wall and area lighting applications such as: . parking lots . stores . office buildings . fast food restaurants . banks . warehouses . schools . parking garages . shopping centers In short, it can be used to illuminate the outside perimeter of virtually any building where precise cutoff control is required. This fixture's aesthetically pleasing appearance will complement any architectural setting, and its vandal-resistant construction is designed to last Front Access Door Incorporating Lens Assembly - Removable, one-piece, injection molded, UV stabilized door and clear lens hinges for full front access H.P.S. units feature polycarbonate for maximum vandal resistance. Metal Halide units come standard with Hubbell's exclusive UL TRACRYL" non- yellowing high temperature acrylic. Interior door surface finished in bronze. . Rear Housing - One-piece, heavy-duty, die cast for long life and cooler operation. Reflector - Precision formed ANODAL@ finished hammered aluminum for optimum performance. Ballast - Class "H" insulated, -4Q"F starting (-20"F for MH), 60 Hz HPF. An aluminum ballast compartment cover isolates electrical components from optical assembly. Additional Features - Field adjustable socket for variable cutoff angle . . . Bronze LEKTROCOTE@ finish . . . two W' side entries for surface conduit mounting . . . accessory photocontrol mounts behind prismatic window . . . accessory housing for single and double pole mounted Perimashield luminaires. . . U.L listed, suitable for wet locations. . . medium base socket (lamp included). t ~ECn\Jt.\) j~\~ 'l. 1~~~ DOCS DIMENSIONS ,- (0) 'I 14'/2" (368 mm) . ....................... :-.1....1........'1 := 1..,1:. 14" (356 mm) 1 tI tI T 5'12" (140 mm) .l Project Type Catalog Number Remarks t:~~~k}.~ .. Lighting ORDERING INFORMATION Catalog Number Lamps and Wattage" VoltagelBall8st HIGH PRESSURE SODIUM PR8-00708-118 70 Quad/ AL APF 18 8 PR8-0070S-511 70 120/Reactor NPF 18 8 PRS-0100S-118 100 Quad/AL HPS 19 9 PRS-01008-511 100 120/Reactor NPF 19 9 PRS-G150S.118 150 Quad/AL HPS 20 9 PRS-0150S-511 150 120/Reactor NPF 20 9 METAL HAUDE PRS-0100H-118 100 Ouad/PLA HPF 9 PRS-0175H.1\8 175 Quad/PLA HPF 9.5 "Medium Base Lamps Included. ACCESSORIES For field installation with Perimashield series. Order separately. Catalog Number Description ECO.F Single in-line fuse holder for 120 and 2n volts. (Fuse not included.) ECO.FF Double in-line fuse holder for 208 and 240 volts. (Fuse not included.) FUSE-5A Single in-line fuse and holder for 120 and 2n volts FUSE-10A Double in-line fuse and holder for 208 and 240 volts PBT-1 Photocontrol, 120 volt (PVL-PK wiring kit required.) PBT -2, 3, 4 Photocontrol, 208, 240, 2n volt (PVL-PK wiring kit required.) PVL.PK Gasket and wiring kit for photocontrol. (Photocontrol not included.) Required when photocontrol is used PVL.PT Aluminum slipfitter housing accepts 2%- 0.0. tenon for single or back-ta-back double, post-top mounted Perimashield luminaires. Bronze LEKTROCOTE@ finish. EPA: 1.8 sq. It with fixtures. PVL.TR Tamper resistant hardware kit SUGGESTED SPECIFICATION GENERAL Luminaire shall be Hubbell Lighting Perimashield Series, catalog number PRS- for use with a watt lamp. MECHANICAL Back housing shall be one-piece; die-cast aluminum with internal heat sink design for cool ballast operation and long life. The housing shall have integrally cast hinge pins to mount the door. Housing shall be capable of being mounted directly over a standard 4- outlet box. Two %- knockouts with an industry standard 10" spacing shall be provided for bolting the fixture to a wall or the pole mounting accessory. Two V2- NSPM tapped and plugged conduit hubs shall be provided for surface conduit wiring. A cast-in channel shall be provided for surface conduit wiring. A cast-in channel shall also be provided to retain the extruded silicone gasket The ballast housing shall have bronze LEKTROCOTE@) finish. The front access door and clear lens shall be one-piece injection- molded. The door and lens for high pressure sodium units shall be u.v. and thermal stabilized polycarbonate. The door and lens for metal MOUNTING DETAILS Ease of installation: . Wall mounting Loosen captive lens retaining screws and reflector retaining screws. Remove reflector. The two %- K.O.'s with an industry standard 10" spacing are now ac- cessible. . Perimashield is designed for mounting directly over a 4- standard outlet box, and is also provided with V2- NPSM tapped and plugged hubs on both sides for surface conduit mounting. . Pole Mounting Standard unit mounts directly to PVL-PT accessory for single or double fixture mounting. Slipfit accessory onto pole tenon. halide shall be U.V. stable ULTRACRYL™ high-temperature acrylic. The door shall have two hinges molded-in to mate with the rear housing hinge pins allowing full front access and removal of the door. The door shall be retained by two captive stainless steel screws to ensure proper gasket sealing. The door shall have a prismatic window for optional photocontrol operation, allowing operation only by light from above the fixture. An aluminum cover shall be provided to enclose the electrical components while the door is opened for relamping. A knockout shall be provided in this cover for field installation of the optional photocontrol. A wiring compartment and cover shall be provided for connection of the power supply. The reflector shall be constructed from high quality hammered aluminum with ANODAL@finish. The medium-base lampholder shall be heavy-duty glazed porcelain and shall be field-adjustable from 700 - 900 to provide customized aiming. ELECTRICAL The ballast shall be class "H" insulated, -200F starting (_400F HPS), 60 Hz high power factor type or normal power factor reactor type. CURVE NO. HP.04801 PRS.0150S.118 II1G. CORREC. ~ HGT. FAClOR ~ 11 1.86 12 1.56 ~ 13 1.33 ;! 14 1.15 I 15 1.00 ~ 16 0.88 w~ 17 0.78 0- 18 0.69 !!! 19 0.62 0 20 0.56 I 21 0.51 .. 5 5 1 2 3 4 5 6 7 8 22 0.46 .. 1 2 3 4 5 6 7 8 RATIO OF LONGITUOINAL DISTANCE yP MOUIlTlNG H~IGHT l!i RATIO OF LONGITUDINAL OISTANCE m MOI.!W'NG HEIGHT .00 .10 .20 .30 .40 .50 .60 .70 .80 ~ .00 .10 c'U2.OCOEFFIC.30 IEN.4TOOF u.5nLI7.c:r6ION .70 .80 CU-COEFFlCIENT OF unLIZATION ~ - ~t position ..till mInImum cutoff. Soclatt position ..t at maxlmum cuto". To determine Iootcanclle val.... for 70W .ncI100W HPS, multiply by .39 and.59 Rl8plICtlYaly. ... o i ~~~~ .. lighting CURVE NO. Hp.04802 II1G. HOt 11 12 13 14 15 16 17 18 19 20 21 22 CORREe. FAClOR 1.86 1.56 1.33 1.15 1.00 0.88 0.78 0.69 0.62 0.56 0.51 0.46 Hubbell/Lighting Division, 2000 Electric Way, Christiansburg, Virginia 24073, (703) 382-6111 . Fax: (703) 382-1526 . Telex: 23-7407719 Hubbell Canada, Inc., 870 Brock Road S., Box 100, Pickering, Ontario L 1 V2R3, (416) 839-1138 . Fax: (416) 839-9108 . Telex: 06-981288 Harvey Hubbell, Ltd., Ronald Close, Woburn Rd. Ind. Estate, Kempston, Bedford, England MK42-7SH. Tel (44 234)855444. Telex: 826065 July 1990 C> 1990 Hubbell Incorporated Printed in U.SA