HomeMy WebLinkAboutLighting Info
PERIMASHIELD™
. Sharp Cutoff optical system eliminates
glare and light trespass
. Field adjustable aiming allows for
customized illumination
. Wall or pole mount
The Perimashield luminaire is ideal for exterior lighting applications
where sharp cutoff is required. This versatile luminaire features
adjustable cutoff from 70" to 90" to prevent light trespass or glare.
This luminaire is perfectly suited for commercial and industrial wall
and area lighting applications such as:
. parking lots . stores
. office buildings . fast food restaurants
. banks . warehouses
. schools . parking garages
. shopping centers
In short, it can be used to illuminate the outside perimeter of virtually
any building where precise cutoff control is required.
This fixture's aesthetically pleasing appearance will complement
any architectural setting, and its vandal-resistant construction is
designed to last
Front Access Door Incorporating Lens Assembly -
Removable, one-piece, injection molded, UV stabilized door and
clear lens hinges for full front access H.P.S. units feature
polycarbonate for maximum vandal resistance. Metal Halide units
come standard with Hubbell's exclusive UL TRACRYL" non-
yellowing high temperature acrylic. Interior door surface finished
in bronze. .
Rear Housing - One-piece, heavy-duty, die cast for long life and
cooler operation.
Reflector - Precision formed ANODAL@ finished hammered
aluminum for optimum performance.
Ballast - Class "H" insulated, -4Q"F starting (-20"F for MH), 60
Hz HPF. An aluminum ballast compartment cover isolates electrical
components from optical assembly.
Additional Features - Field adjustable socket for variable cutoff
angle . . . Bronze LEKTROCOTE@ finish . . . two W' side entries
for surface conduit mounting . . . accessory photocontrol mounts
behind prismatic window . . . accessory housing for single and
double pole mounted Perimashield luminaires. . . U.L listed, suitable
for wet locations. . . medium base socket (lamp included).
t
~ECn\Jt.\)
j~\~ 'l. 1~~~
DOCS
DIMENSIONS
,- (0)
'I
14'/2"
(368 mm)
. .......................
:-.1....1........'1
:=
1..,1:.
14"
(356 mm)
1
tI
tI
T
5'12"
(140 mm)
.l
Project
Type Catalog Number
Remarks
t:~~~k}.~ .. Lighting
ORDERING INFORMATION
Catalog Number Lamps and Wattage" VoltagelBall8st
HIGH PRESSURE SODIUM
PR8-00708-118 70 Quad/ AL APF 18 8
PR8-0070S-511 70 120/Reactor NPF 18 8
PRS-0100S-118 100 Quad/AL HPS 19 9
PRS-01008-511 100 120/Reactor NPF 19 9
PRS-G150S.118 150 Quad/AL HPS 20 9
PRS-0150S-511 150 120/Reactor NPF 20 9
METAL HAUDE
PRS-0100H-118 100 Ouad/PLA HPF 9
PRS-0175H.1\8 175 Quad/PLA HPF 9.5
"Medium Base Lamps Included.
ACCESSORIES For field installation with Perimashield series. Order separately.
Catalog Number Description
ECO.F Single in-line fuse holder for 120 and 2n volts. (Fuse not included.)
ECO.FF Double in-line fuse holder for 208 and 240 volts. (Fuse not included.)
FUSE-5A Single in-line fuse and holder for 120 and 2n volts
FUSE-10A Double in-line fuse and holder for 208 and 240 volts
PBT-1 Photocontrol, 120 volt (PVL-PK wiring kit required.)
PBT -2, 3, 4 Photocontrol, 208, 240, 2n volt (PVL-PK wiring kit required.)
PVL.PK Gasket and wiring kit for photocontrol. (Photocontrol not included.) Required when
photocontrol is used
PVL.PT Aluminum slipfitter housing accepts 2%- 0.0. tenon for single or back-ta-back double,
post-top mounted Perimashield luminaires. Bronze LEKTROCOTE@ finish. EPA: 1.8 sq. It
with fixtures.
PVL.TR Tamper resistant hardware kit
SUGGESTED SPECIFICATION
GENERAL
Luminaire shall be Hubbell Lighting Perimashield Series, catalog
number PRS- for use with a watt
lamp.
MECHANICAL
Back housing shall be one-piece; die-cast aluminum with internal
heat sink design for cool ballast operation and long life. The housing
shall have integrally cast hinge pins to mount the door. Housing shall
be capable of being mounted directly over a standard 4- outlet box.
Two %- knockouts with an industry standard 10" spacing shall be
provided for bolting the fixture to a wall or the pole mounting accessory.
Two V2- NSPM tapped and plugged conduit hubs shall be provided
for surface conduit wiring. A cast-in channel shall be provided for
surface conduit wiring. A cast-in channel shall also be provided to
retain the extruded silicone gasket The ballast housing shall have
bronze LEKTROCOTE@) finish.
The front access door and clear lens shall be one-piece injection-
molded. The door and lens for high pressure sodium units shall be
u.v. and thermal stabilized polycarbonate. The door and lens for metal
MOUNTING
DETAILS
Ease of installation:
. Wall mounting
Loosen captive lens retaining
screws and reflector retaining
screws. Remove reflector.
The two %- K.O.'s with an industry
standard 10" spacing are now ac-
cessible. .
Perimashield is designed for
mounting directly over a 4-
standard outlet box, and is also
provided with V2- NPSM tapped and
plugged hubs on both sides for
surface conduit mounting.
. Pole Mounting
Standard unit mounts directly to
PVL-PT accessory for single or
double fixture mounting. Slipfit
accessory onto pole tenon.
halide shall be U.V. stable ULTRACRYL™ high-temperature acrylic.
The door shall have two hinges molded-in to mate with the rear housing
hinge pins allowing full front access and removal of the door. The
door shall be retained by two captive stainless steel screws to ensure
proper gasket sealing. The door shall have a prismatic window for
optional photocontrol operation, allowing operation only by light from
above the fixture.
An aluminum cover shall be provided to enclose the electrical
components while the door is opened for relamping. A knockout shall
be provided in this cover for field installation of the optional
photocontrol. A wiring compartment and cover shall be provided for
connection of the power supply.
The reflector shall be constructed from high quality hammered
aluminum with ANODAL@finish. The medium-base lampholder shall
be heavy-duty glazed porcelain and shall be field-adjustable from
700 - 900 to provide customized aiming.
ELECTRICAL
The ballast shall be class "H" insulated, -200F starting (_400F HPS),
60 Hz high power factor type or normal power factor reactor type.
CURVE NO. HP.04801 PRS.0150S.118
II1G. CORREC. ~
HGT. FAClOR ~
11 1.86
12 1.56 ~
13 1.33 ;!
14 1.15 I
15 1.00 ~
16 0.88 w~
17 0.78
0-
18 0.69 !!!
19 0.62 0
20 0.56 I
21 0.51 .. 5
5 1 2 3 4 5 6 7 8 22 0.46 .. 1 2 3 4 5 6 7 8
RATIO OF LONGITUOINAL DISTANCE yP MOUIlTlNG H~IGHT l!i RATIO OF LONGITUDINAL OISTANCE m MOI.!W'NG HEIGHT
.00 .10 .20 .30 .40 .50 .60 .70 .80 ~ .00 .10 c'U2.OCOEFFIC.30 IEN.4TOOF u.5nLI7.c:r6ION .70 .80
CU-COEFFlCIENT OF unLIZATION ~ -
~t position ..till mInImum cutoff. Soclatt position ..t at maxlmum cuto".
To determine Iootcanclle val.... for 70W .ncI100W HPS, multiply by .39 and.59 Rl8plICtlYaly.
...
o
i
~~~~ .. lighting
CURVE NO. Hp.04802
II1G.
HOt
11
12
13
14
15
16
17
18
19
20
21
22
CORREe.
FAClOR
1.86
1.56
1.33
1.15
1.00
0.88
0.78
0.69
0.62
0.56
0.51
0.46
Hubbell/Lighting Division, 2000 Electric Way, Christiansburg, Virginia 24073, (703) 382-6111 . Fax: (703) 382-1526 . Telex: 23-7407719
Hubbell Canada, Inc., 870 Brock Road S., Box 100, Pickering, Ontario L 1 V2R3, (416) 839-1138 . Fax: (416) 839-9108 . Telex: 06-981288
Harvey Hubbell, Ltd., Ronald Close, Woburn Rd. Ind. Estate, Kempston, Bedford, England MK42-7SH. Tel (44 234)855444. Telex: 826065
July 1990 C> 1990 Hubbell Incorporated Printed in U.SA