Loading...
HomeMy WebLinkAboutC802 STORM & DRAINAGE DETAILS1/2" PREFORMED 6" 4" 6" SLOPE 1/2" & EXP. JT. � W/ BROOM FINISH PVMT. i PVMT. d. _V) _ _ Q 1=1 I M I I I —III 11=1I ACO K 100 PRECAST =1II=1II=1II a 1 III=III=1' TRENCH DRAIN W/ ADA =III=III=III III=III—II DUCTILE IRON GRATE =1I1=1II e II1=1II IIII IIII d ° 11111111E COMPACTED SUBGRADE TRENCH DRAIN DETAIL NTS 1 � a � 1 � rr•� .. 1 � : r• 1 i • a• 1 MUNCHING (Bc/6 BEDDING LLULNU : Bc = OUTSIDE DIAMETER D = INSIDE DIAMETER d = DEPTH OF BEDDING MATERIAL BELOW PIPE SPRINGUNE DEPTH OF BEDDING `MATERIAL BELOW PIPE d n d UIN I Bc I 66' do LARGER 6" NOTES' 1. BEDDING AND MUNCHING FOR ALL RCP INSTALLATIONS SHALL BE 08 STONE MEETING THE MATERIAL REQUIREMENTS OF THE INDOT. BEDDING SHALL BE PLACED IN THE TRENCH BOTTOM SUCH THAT AFTER THE PIPE IS INSTALLED TO GRADE AND UNIE, THERE REMAINS A 4" MINIMUM DEPTH OF MATERIAL BELOW THE PIPE BARREL AND A MINIMUM OF 3" BELOW THE BELL FOR PIPE SIZES 66- AND LARGER, THE MINIMUM DEPTH OF MATERIAL BELOW THE PIPE BARREL SHALL BE 6-. BEDDING SHALL BE PLACED TO BE UNIFORM AS POSSIBLE, BUT SHALL BE LOOSELY PLACED UNCOMPACTED MATERIAL UNDER THE MIDDLE THIRD OF THE PIPE PRIOR TO PLACEMENT OF THE PIPE. IF THE UNDERLYING SOILS OF THE TRENCH BOTTOM ARE SOFT OR YIELDING, THE SOIL SHALL BE UNDERCUT TO SUCH A DEPTH THAT WHEN REPAIRED WITH #2 STONE IT WILL PRODUCE A UNIFORM AND STABLE FOUNDATION ALONG THE ENTIRE LENGTH OF THE PIPE MUNCHING AND INITIAL BACKFILL SHALL BE COMPACTED IN 8' MAXIMUM LIFTS TO NOT LESS THAN 90% STANDARD PROCTOR DENSITY FOR THE ENTIRE DEPTH OF THE MATERIAL PLACED. THE BACKFILL SHALL BE BROUGHT UP EVENLY ON BOTH SIDES OF THE PIPE FOR THE FULL LENGTH OF THE PIPE. MUNCHING SHALL EXTEND TO THE SPRINGUNE OF THE PIPE MINIMUM TRENCH WIDTH SHALL BE THE OUTSIDE DIAMETER OF THE PIPE PLUS 18'. 2. FINAL BACKFILL FOR ALL RCP INSTALLATIONS WHERE "L' IS 5' OR LESS SHALL BE B—BORROW FOR STRUCTURE BACKFILL MEETING THE MATERIAL REQUIREMENTS OF THE INDOT AND SHALL BE COMPACTED IN 6" MAXIMUM LIFTS TO NOT LESS THAN 95% STANDARD PROCTOR DENSITY FOR THE ENTIRE DEPTH OF THE MATERIAL PLACED. THE BACKFILL FOR THE TOP 6' OF THE EXCAVATION BELOW THE LIMIT OF SUBGRADE SHALL BE #53 STONE MEETING THE MATERIAL REQUIREMENTS OF THE INDOT AND SHALL BE COMPACTED TO NOT LESS THAN 95X STANDARD PROCTOR DENSITY. FINAL BACKFILL FOR ALL RCP INSTALLATIONS WHERE "L' IS GREATER THAN 5' SHALL BE CLEAN FILL MATERIAL FREE OF ROCKS LARGER THAN 6' IN DIAMETER, FROZEN LUMPS OF SOIL, WOOD OR OTHER EXTRANEOUS MATERIAL, COMPACTED IN 12' MAXIMUM LIFTS TO NOT LESS THAN 90% STANDARD PROCTOR DENSITY FOR THE ENTIRE DEPTH OF THE EXCAVATION. CONTRACTOR SHALL PROVIDE A 3rd PARTY TESTING AGENCY TO PROVIDE COMPACTION TESTING AS NECESSARY. 3. FOR INSTALLATION OF STORM MAINS, WATERMAINS, SANITARY MAINS, WATER SERVICE LATERALS, AND SANITARY SERVICE LATERALS UNDER CITY STREETS, REGARDLESS OF THE JURISDICTION OF THE UTILITY, THE MINIMUM COVER FROM THE TOP OF THE INSTALLED PAVEMENT OR FINAL GROUND ELEVATION TO THE TOP OF THE INSTALLED PIPE SHALL BE NO LESS THAN 2.5 FEET OF COVER ALONG ANY PART OF THE PIPE. IF THE STANDARD PRACTICE OF THE UTILITY THAT HAS JURISDICTION OVER THE INSTALLATION HAS A MORE STRINGENT COVER REQUIREMENT, THE MORE STRINGENT REQUIREMENT SHALL GOVERN. 4. IF EXISTING SUBGRADE HAS BEEN LIME STABILIZED, BACKFILL WITH B—BORROW TO BOTTOM OF EXISTING SUBGRADE AND FILL TO THE LIMIT OF EXISTING SUBGRADE WITH COMPACTED AGGREGATE NO 53. 5. THESE STANDARDS SHALL APPLY FOR STORM SEWERS INSTALLED WITHIN EXISTING AND PROPOSED CITY R/W AND FOR STORM SEWERS THAT SHALL BE MAINTAINED BY THE CITY, REGARDLESS OF STORM SEWER JURISDICTION. 6. ALL STORM PIPE WITHIN EXISTING OR PROPOSED CITY R/W SHALL BE REINFORCED CONCRETE PIPE REGARDLESS OF JURISDICTION OVER STORM PIPES. STANDARD CITY OF CARMEL STANDARDS DRAWING 10-31 TRENCH DETAIL FOR CITY STORM SEWERS TRENCH DETAIL FOR RCP STORM SEWERS NTS EARTH OR SIDEWALK SURFACE UNDERDRAIN TRENCH TO BE FLUSH WITH BACK OF CURB CONCRETE CURB OR CURB dt GUTTER PAVEMENT—\ ASPHALT OR COMPACTED AGGREGATE 1 1 ���. .11��. 11 • �'i 1 • 71 1 - - • 7' " 1 1 1 1 1 NOTES' PIPE SHALL CONFORM TO SPEC REQUIREMENTS OF SECTION 718 OF STANDARD SPECIFICATION INSTALLATION REQUIRED' BOTH SIDES OF PAVEMENT AND WHERE REQUESTED BY THE CITY ENGINEER STANDARD DRAWING CITY OF CARMEL STANDARDS 10-12 UNDERDRAIN 6" 10" 6" SLOPE 1/2" PAVEMENT PAVEMENT 'd BROOM FINISH IF 4 NEENAH R-4990DX W/ "C" GRATE & "X" FRAME a d. ° I —III —II. III—III=11 v, =III=III=III=III=III=IJ�=III=III=11'—COMPACTED SUBGRADE I I i l l l l_,III=1 I I I � I I I I-1 I I=1 I I —III —I I I TRENCH DRAIN DETA L / NTS NO SCALE OFFICE OF THE HAMILTON COUNTY SURVEYOR ASTING FRAME AND COVER AS SPECIFIED NUN -ASPHALTIC MASTIC OR BUTYL RUBBER x SEAL BETWEEN JOINTS. ;S CV PRECAST CONCRETE ADJUSTER RINGS IF NEEDED (12 INCHES OF RINGS MAXIMUM). 24" DIAMETER— ............... ECCENTRIC CONE OR REDUCER CAP AS REQUIRED BY SITE =': �• �� CONDITIONS. CONE TOP TO �___4 MATCH ADJUSTING RING PROFILE. - ---------- FULL HEIGHT MANHOLE P STEPS AS SPECIFIED. ' 5" MINIMUM NOTE: .� MANHOLE CONFORMS - TO ASTM 478 op � O-RING GASKET NON - ASPHALTIC MASTIC OR BUTYL RUBBER SEAL 48" DIAMETER PRECAST AT JOINTS. CONCRETE SECTION PREFORMED HOLE TO MAXIMUM OF PIPE U.D. •8" WITH BENCH HALLS AT MINIMUM NON -SHRINK CEMENT GROUT. /2" PER FOOT SLOPE. BENCH WALLS TO BE CONSTRUCTED TO SPRING LINE OF PIPE. �. • :'' NOTE: STRUCTURES ARE TO BE . ; : '' • ' GROUTED FULLY, TROWELED ' �•' ' ' SMOOTH AND BRUSH FINISHED. REINFORCED BAR PRECAST BASE•'`'�" B' OR 8' PER SECTION w4 Q 12" ON CENTER OR APPROVED ALTERNATIVE •' 3" MINIMUM MANHOLE SASE SET ON 8" OF 2 STONE STANDARD MANHOLE FOR PIPE SIZES 12 THRU 24" (DRAWING NOT TO SCALE) HAMILTON COUNTY SURVEYOR'S OFFICE REVISED- 1 FEB 2002 STANDARD PLAN APPROVED: - Z ATE D _ KENTON C. WAR AMILTON COUNT SURVEYOR 48" DIA. STORM MANHOLE DETAIL NTS OFFICE OF THE HAMILTON COUNTY SURVEYOR CASTING FRAME STANDARD MANHOLE AND COVER AS SPECIFIED FOR PIPE SIZES 24ItTHRU 66" x PRECAST CONCRETE ADJUSTER RINGS IF CV At NEEDED (12 INCHES OF RINGS MAXIMUM). NON -ASPHALTIC 24.. MASTIC OR DIAMETER BUTYL RUBBER STANDARD PRECAST MANHOLE CAP OR CONE SEAL BETWEEN JOINTS 5" MINIMUM\. 4' DIAMETER /5" MINIMUM NON -ASPHALTIC MASTIC OR BUTYL RUBBER SEAL BETWEEN JOINTS 18" TYPICAL MANHOLE PIPE PIPE TURNS DIA. "F" DIA. "G" 98" 48" GREATER THAN 45 TO 90 DEG 98" 54"-66" UP TO 80 DEG 84" 42" GREATER THAN 45 TO 90 DEG 84" 48" TURNS UP TO 45 DEC 72" 42"-48" UP TO 45 DEC 80" 33"-36" STRAIGHT THRU 80" 24"-33" GREATER THAN 45 TO 90 DEG FULL HEIGHT MANHOLE STEPS AS SPECIFIED ------------- CONCRETE REDUCER CAP NOTE: -MANHOLE CONFORMS TO ASTM C-478 -NO BRICK OR BLOCK WILL BE ALLOWED IN MANHOLE -O-RING GASKET. NON- DIA• "F" ASPHALTIC MASTIC OR BUTYL RUBBER SEAL 1' MIN. OVER BETWEEN JOINTS HIGHEST PIPE PREFORMED HOLE TO MAXIMUM OF PIPE O.D. •8" WITH NON -SHRINK CEMENT GROUT ,Cf I/BENCH WALLS AT MINIMUM " PER FOOT SLOPE. BENCH ';:.. ':.', ■ ■ : ,,• WALLS TO BE CONSTRUCTED • . , TO SPRING LINE OF PIPE. 3" MIN. ,•'■,•'■, '• •.■,■••.■;, ,�■'•.� 8" MIN. 3" MIN. ONE COMPLETE UNIT OF PRECAST CONCRETE (DRAWING NOT TO SCALE) MANHOLE BASE AND RISER OR APPROVED ALTERNATIVE HAMILTON COUNTY SURVEYOR'S OFFICE REVISED: 1 FEB 2002 STANDARD PLAN APPROVED: z• ► D _ 1 KENTON C.W60. HAMILTON CO NTY SURVEYOR DATE Aqua -Swirl® Polymer Coated Steel (PCS Stormwater Treatment System Projected View SCALE 1 ■70 / Unless other traffic barriers are present, bollards shall be placed around access riser(s) in non -traffic areas to prevent inadvertent loading by maintenance vehicles. 48 in [1219 mm] Min. 1/2 in 12 in 4 1/2 in Concrete Cover [1 / in [305 mm] 1114 mm] Soil ,.y Please see accompanlea Aqua-bwlrlCU speclticatlon notes. bee bite Plan for actual System orientation. Approximate dry (pick) weight: 3800 Ibs [1700 kg]. O As an alternative, 42 in [1067 mm] diameter, HS-20/25 rated precast concrete rings may be substituted. 14 in [356 mm] thickness must be maintained. Gravel Bac ' rame O 48 in [1219 mm] Min. inO XC-7 inlet/outlet pipe size ranges up to 42 in [1067 mm]. 1111 1/2 in Backfil 190% [13 mm] 8 in [203 mm] Cover­,..,[114 mm] Proctor Density) Riser Place small amount of #4 [13 mm] Reba r @ 6 in [152 mm] 3O XC-7 chamber height may vary up to 156 in [3962 mm], WrapCompressible Expansion Joint Material to a minimum Manhole Frame & Cover Detail concrete [3,000 psi [20 MPa] (min)] to support Each Way depending on inlet outlet pipe size. p 9 / p p 1/2-inch 13 mm thickness around / [ ] For Non -Traffic Areas only top of riser to allow transfer of NTS and level manhole frame. 3,000 psi [20 MPa] (min) Concrete 30 in [762 mm] 14 in 356 mm [ ] inadvertent loading from manhole cover to concrete slab. DO NOT allow manhole frame to rest upon riser. Backfill (90% Riser O Orientation may varyfrom a minimum of 900 to a 1/2 in [13 mm] Thick 4 y Proctor Density) Expansion Joint maximum of 1801. Clockwise or counterclockwise Manhole Frame & Cover Detail For Traffic Loading Areas Material orientation as needed. NTS 030 in [762 mm] Manhole Frame and Cover by Manufacturer. Rim elevations to 102 in _ (See Details) match finishh r � WF'ame [2591 mm] Grade (Rim) el. Varies [127 mm] ® B dC I Frame 1/2 in [13 mm] Optional inlet 180° Octagonal Base Plate an oup er Riser orientations available Varies by Manufacturer. (See note 4) (as needed) Lifting Lugs Varies 090 in el. Varies [0229 mm] Lifting Lugs 102 in [2591 mm] } 042 in ■ 2 [1067 mm] 24" ADS N-12 MANIFOLD PIPE IN Pipe coupling by Contractor. 12 in [305 mm] long Stub -out by Manufacturer. i� -Plan Vie SCALE 1:40 042 in [1067 mm] ■ Pipe coupling by Contractor. 12 in [305 mm] long Stub -out by Manufacturer. Inlet/Outlet Invert el. Varies 156 in ® [3962 mm] 90 in [2286 mm] el. Varies 090 in [2286 mm] 6 in [152 mm] Elevation View SCALE 1:40 Backfill shall extend at least 18 inches [457 mm] outward from Swirl Concentrator and for the full height of the Swirl Concentrator (including riser) extending laterally to undisturbed soils. (See MH Detail Below) 18 in T CARMEI LATER PEDCOR DESIGN GROUP LLC Architecture / Project Management: 355 City Center Drive Carmel, Indiana 46032 317.705.7979 (phone) 317.705.7980 (fax) Engineer: I I I I I I1/1/// 0 .. fR ,' .. �i G�ST�� :%19 910023 ;• STATE OF :?QZ o,�,• ,, ss By: Developer: P E D C O R DEVELOPMENT CO. Project: AQUA —SWIRL XCELERATOR XC-7 CCW BMP (STR. 7)(� NO SCALE 6'-0 N ELEV. 830.87 ELEV. 828.70 2.8• DNA.Yl— 1 /2" STEEL PLATE WITH 1/2'x2" GALVANIZED '- STEEL BOLTS ELEV. 825.20 2.1"DIA. ELEV. 823.79 ELEVATION NON —CORROSIVE ORIFICE PLATE DIKE F-I C\/ Q77 An 72" DIA. MANHOLE 3EE DETAIL 08/C802 E PLATE DS N-12 MANIFOLD PIPE IN (N) 4" RCP OUT (E) ELEV. 823.79 #2 STONE BEDDING SECTION NOTES: 1. DIMENSIONS AND STRUCTURAL DESIGN SHALL BE PERFORMED BY CONCRETE MANUFACTURER. 2. MANHOLE SHALL CONFORM TO ASTM C478 OUTLET CONTROL MANHOLE DETA L o° WEEP HOLES " 2'-0 SQ NO SCALE cn �. w 6';:. WEEP HOLES Q z ° D 4 Q ti ° .. n, Oo .4 � D v v v v 6" STONE BASE SEE SHEET C301 FOR PIPE SIZES AND INVERT ELEV. INLET TYPE 'A M O D F E D' EDGE OF PAVEMENT, CURB, GUTTER OR 5' OR LESS SIMILAR STRUCTURE IN THE PUBLIC R/W CLEANOUT COVER THREADED -TYPE WATER TIGHT & CAPPED AT ALL TIMES FINISH GRADE-, CLEANOUT PLUG ROUND FLANGED HOUSING ,W/HEAVY DUTY CAST IRON COVER JAY R. SMITH 4251 /18"X18"X4" THICK CONCRETE PAD RISER PIPE SAME AS SEWER STORM CLEANOUT NO SCALE ACE OF BUILDING DOWNSPOUT SLOPE TYPE 'A' TYPE 'B' TYPE 'C' SELF LEVELING URETHANE SEALANT, COLOR AS SELECTED BY ARCHITECT CAST IRON DOWNSPOUT BOOT O BY NEENAH -SERIES R-4924-28 (TYPE A, B, OR C) COORDINATE TYPE, SIZE AND w COLOR WITH ARCHITECT. STORM SEWER PIPE - SEE GRADING & DRAINAGE PLAN FOR SIZE & SLOPE _ FINISH GRADE zZ J 0 0 DOWNSPOUT BOOT DOWNSPOUT CONNECT ON DETA L MIN. 6" TOPSOIL TO ENSURE GRASS GROWTH IF NOT UNDER PVMT. NO SCALE EDGE OF PAVEMENT, CURB, GUTTER OR GREATER THAN 5' MIN. 6" TOPSOIL SIMILAR STRUCTURE TO ENSURE GRASS IN THE PUBLIC R/W­—GROWTH "B" BORROW OR EQUIV. 1.25 Bc+12" ■/ NOTE: % MIN. 1.25 Bc+12": GRANULAR MATERIAL �\ ALL BEDDING & INITIAL BACKFILL \\ COMPACTED TO 95% SHALL BE INSTALLED IN 6" TO 12" BALANCED LIFTS STANDARD PROCTOR REGULAR BACKFILL DENSITY IN. 12" MIN. 12" A MINIMUM 9" CLEARANCE SHALL #8 CRUSHED STONE OR BE PROVIDED ON EACH SIDE OF #8 CRUSHED STONE OR APPROVED EQUIV. THE INSTALLED PIPE (Bc < 12") APPROVED EQUIV. CLASS I BEDDING MATERIAL LEGEND CLASS I BEDDING MATERIAL HAND TAMPED OR WALKED HAND TAMPED OR WALKED INTO PLACE gc // Bc=OUTSIDE DIAMETER INTO PLACE Bc \� 4 D=INSIDE DIAMETER / 4„ ,....- ■. d=DEPTH OF BEDDING MATERIAL BELOW PIPE WITHIN 5' OF EDGE OF PAVEMENT GREATER THAN 5' FROM EDGE OF PAVEMENT PIPE TRENCH BACKF LL (HDPE & PVC) ■■ COPYRIGHT & OWNERSHIP OF DOCUMENTS THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINALAND PUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAYBE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. O COPYRIGHT 2022 JAMES R. STUTZMAN, AIA, Carmel, Indiana. CONSTRUCTION DOCUMENTS Set Issue Date Sheet Issue Date 01 /30/2023 05/04/2023 Drawn By Checked By DBH RDM Last Revision Date: 03/30/23 - CARMEL REVIEW 05/04/23 - CARMEL REVIEW Project Number: 21071.001 Sheet Title: STORM & DRAINAGE DETAILS Sheet Number: C802 STREET CURB UNDER —DRAIN DETAIL NTS 60"-96" DIA. STORM MANHOLE DETAIL NTS SCALE: 3/4"=1'O" NO SCALE