HomeMy WebLinkAboutsolar_simulation_concourse_102422Annual Production Report produced by Telamon Energy (Confidential) © 2022 Aurora Solar 1 / 3 October 24, 2022 Design 1 The Concourse - Carmel, IN, 550 Monon Boulevard, Carmel, IN 46032 Project Name The Concourse - Carmel, IN Project Address 550 Monon Boulevard, Carmel, IN 46032 Prepared By Telamon Energy (Condential) mike.morley@telamon.com Report Design Design 1 Module DC Nameplate 15.8 kW Inverter AC Nameplate 15.0 kW Load Ratio: 1.06 Annual Production 21.98 MWh Performance Ratio 82.9% kWh/kWp 1,387.8 Weather Dataset TMY, 10km Grid (39.95,-86.15), NREL (prospector) Simulator Version 37f8f204a2-6a81e7e69b-0ab5192cca- 6e779f29d7 System Metrics Project Location Monthly Production kWhJan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 0 1k 2k 3k Sources of System Loss ShadingShading: 0.0%: 0.0%Shading: 0.0% ReflectionReflection: 3.1%: 3.1%Reflection: 3.1% SoilingSoiling: 2.0%: 2.0%Soiling: 2.0% IrradianceIrradiance: 0.6%: 0.6%Irradiance: 0.6% TemperatureTemperature: 6.9%: 6.9%Temperature: 6.9% MismatchMismatch: 3.0%: 3.0%Mismatch: 3.0% WiringWiring: 0.2%: 0.2%Wiring: 0.2% ClippingClipping: 0.0%: 0.0%Clipping: 0.0% InvertersInverters: 2.5%: 2.5%Inverters: 2.5% AC SystemAC System: 0.0%: 0.0%AC System: 0.0% Annual Production Report produced by Telamon Energy (Confidential) © 2022 Aurora Solar 2 / 3 October 24, 2022 Description Output % Delta Irradiance (kWh/m ) Annual Global Horizontal Irradiance 1,464.2 POA Irradiance 1,674.9 14.4% Shaded Irradiance 1,674.7 0.0% Irradiance after Reection 1,623.4 -3.1% Irradiance after Soiling 1,590.9 -2.0% Total Collect or Irradiance 1,590.9 0.0% Energy (kWh) Nameplate 25,197.7 Output at Irradiance Levels 25,039.6 -0.6% Output at Cell Temperature Derate 23,302.0 -6.9% Output After Mismatch 22,606.4 -3.0% Optimal DC Output 22,550.7 -0.2% Constrained DC Output 22,550.3 0.0% Inverter Output 21,986.5 -2.5% Energy to Grid 21,982.9 0.0% Temperature Metrics Avg. Operating Ambient Temp 13.3 °C Avg. Operating Cell Temp 29.8 °C Simulation Metrics Operating Hours 4679 Solved Hours 4679 Annual Production 2 Description Condition Set 1 Weather Dataset TMY, 10km Grid (39.95,-86.15), NREL (prospector) Solar Angle Location Meteo Lat/Lng Transposition Model Perez Model Temperature Model Sandia Model Temperature Model Parameters Rack Type a b Temperature Delta Fixed Tilt -3.56 -0.075 3°C Flush Mount -2.81 -0.0455 0°C Soiling (%) J F M A M J J A S O N D 2 2 2 2 2 2 2 2 2 2 2 2 Irradiation Variance 5% Cell Temperature Spread 4° C Module Binning Range -2.5% to 2.5% AC System Derate 0.50% Trackers Maximum Angle Backtracking 60°Enabled Module Characterizations Module Uploaded By Characterization Q.PEAK DUO XL-G10.2 480 (2021) (Hanwha Q Cells)HelioScope Spec Sheet Characterization, PAN Component Characterizations Device Uploaded By Characterization Sunny Tripower 15000TL-US STPTL- US12-30-DUS173127 (SMA)HelioScope Spec Sheet Condition Set Component Name Count Inverters Sunny Tripower 15000TL-US STPTL- US12-30-DUS173127 (SMA) 1 (15.0 kW) AC Home Runs 1 AWG (Aluminum)1 (53.1 ft) Strings 10 AWG (Copper) 3 (138.0 ft) Module Hanwha Q Cells, Q.PEAK DUO XL- G10.2 480 (2021) (480W) 33 (15.8 kW) Components Description Combiner Poles String Size Stringing Strategy Wiring Zone -7-16 Along Racking Wiring Zones Description Racking Orientation Tilt Azimuth Intrarow Spacing Frame Size Frames Modules Power Field Segment 1 Flush Mount Landscape (Horizontal)25°180°0.0 ft 1x1 33 33 15.8 kW Field Segments Annual Production Report produced by Telamon Energy (Confidential) © 2022 Aurora Solar 3 / 3 October 24, 2022 Detailed Layout