HomeMy WebLinkAboutLighting
PROJECT WESTON POINTE
Design 123-20/25
EJXTURE TYPE P2 SINGLE ARM MOUNT
CATALOG NUMBER 123-25-F-MH400-CL-DB-VOL T-SA-HSS
DISTRIBUTIONS
TYPE VR Rectangular Symmetrical (Vart. Lamp)
TYPE F Forward Throw (Horiz. Lamp)
TYPE V Symmetrical (Vert. Lamp)
TYPE VS Square (Vertical Lamp)
TYPE 3 Asymmetrical (Horiz. Lamp)
ORDERING EXAMPLE 123-25-VR-HPS-400-CL-DB-120-LA-FD-CL80x360
MH = Sid. Metal Halide CL = Convex glass \ens
MHP = Pulse Start FL = Flat glass lens
DESIGN DISTRIBUTION HPS MHlMHP LAMP LENS
123-20 3 70/100/150 100/150/175/200' ED-17 FL
F 70/100/150 100/150/175/200' ED-17 FL
V 70/100/150 100/150/175/200' ED-17 FL
123-25 VR 250/400 ED-18 CL
VR 250/400 ED-28 CL or FL
VR 400/450' ED-37 CL
VR 750 BT-37 CL
123-25 VS 250/400 ED-18 CL
VS 250/400 ED-28 CL or FL
VS 400/450' ED-37 CL
VS 750 BT-37 CL
123-25 3 250/400 ED-18 FL
3 250 ED-28 FL
3 400 ED-37 FL
3 750 BT-37 FL
123-25 F 250/400 ED-18 FL
F 250 ED-28 FL
F 400 ED-37 FL
F 750 BT-37 FL
. Available only in Pulse Start 100,150,200,450 MHP = Pulse Start
REQUIRED CHOICES
FINISH
BK Black
BW White
DB Bronze
SL Silver
FG Gray
CC Custom
VOLTAGES
120
208
240
277
347
480
MOUNTINGS
SA Standard Arm (2.5")
LA Long Arm (13.5")
CWB Cast Wall Bracket
ESF External Slip Fitter
(for 2-3/8" 0.0. Pipe)
OPTIONAL CHOICES
ELECTRICAL OPTIONS
FD Single Fusing 120V/277V
FDD Double Fusing 480V
FDFD Double Fusing 208V/240V
FDC Single Fusing 347V
PCT Photo Cell and Receptacle
OPTICAL OPTIONS
LX Vandal Resistant Shield
(Lexan lens 400W max.)
LIGHT TRESPASS OPTIONS
CL80x360 Internal 800 Vert. x 360' Horiz. Lens Shielding
CL60x135 Internal 600 Vert. x 135' Horiz. Lens Shielding
HSS House Side Shield (75' Standard) (External)
FL Flat clear glass lens (see ordering inlormation
lor availability)
[JJ~lOl~
CW8
ESF
CL60x135 - Internal
60' Vert. x 135' Horiz.
Lens Shielding
CL80x360 - Internal
80' Vert. x 360' Horiz.
Lens Shielding
There ;s no substitute for
A Division of JJI Lighting Gt<l>'Dj:lI hh'C. ,
Oudiliy ~tintl~
11500 MELROSE AVE. FRANKLIN PARK, IL 60131. Phone (847) 451-0040 - FAX (847) 451-6768
a-mail: quality@mcs.com . www.qualitylighting.com
(72803) Specifications subject to change without notice. @2003 Quality Lighting
1..&1
III
SPECIFICATIONS
H 0 U SIN G Each Design 123 one-piece, reinforced housing shall be constructed of heavy-gauge spun aluminum.
the fixture shall be C-UL & UL listed "su~able for wet locations".
LEN S F RAM E The heavy-duty cast aluminum lens frame shall be hinged to the housing w~ twin stainless steel piano hinges.
LEN SAN 0 GAS K E TIN G The flat or convex thermal and shock resistant glass lens shall be gasketed to the lens frame w~h extruded butyl acrylic
tape sealant secured w~h retainer clips. The lens frame shail be gasketed to the housings internal reinforcement ring
w~h silicone impregnated Dacron gasketing.
M 0 U NT I N G Each Design 123 shall be provided w~h a cast aluminum 2.5" long arm for mounting a single fixture or twin fixtures at 1800.
A 13.5'long aluminum arm is supplied for other mounting configurations.
R E FLE C TO R Design 123 shall be available w~h the following reflector systems: 1) Type VR - rectangular distribution;
2) Type F - forward throw distribution; 3) Type V - symmetrical distribution; 4) Type 3 - asymmetrtcal distribution;
5) Type VS - square vertical lamp. All photometric data shall be certified by an independent testing facility.
BA L LA STAll CWA ballasts (+10% to -10% lamp power regulation) shall be tray mounted and supplied w~ quick-disconnects.
Ballasts are rated for -200 F operation. All non CWA ballast shall be HPF.
FIN ISH Polyester powder coat, electrostatically applied, which is preceded by a five step pre-treatment process including an
iron phosphate priming stage for superior coating adhesion. This process meets or exceeds all ASTM testing requirements,
including those for 1,000 - hour sa~ spray endurance testing.
f
A
tr
B
-1
DIMENSIONS
20' Dia
A 20.00' (50B.00 mm)
B 10.SO' (266.00 mm)
25"Dia.
25.00" (635.00 mm)
11.00" (279.40 mm)
EFFECTIVE PROJECTED AREA (EPA)
Size 20' 25"
1 Fixture 1.40 sq. ft. (.13M2) 2.0 sq. ft. (.19M2)
2 Fixtures 2.80 sq. ft. (.27M2) 4.0 sq. ft. (.38M2)
3 Fixtures 3.85 sq. ft (.37M2) 4.6 sq. ft. (.44M2)
4 Fixtures 4.48 sq. ft. (.43M2) 6.4 sq. ft. (.61 M2)
WEIGHT
20' 36Ibs.(16.33 kgs)
25' 59Ibs.(28.76 kgs)
There Is no substitute for
A Division <llIIJJI Lighting Group Inc.'
o
ouality ~iny~
nnn
11500 MELROSE AVE. FRANKLIN PARK, IL 60131. Phone (B47) 451-0040 - FAX (847) 451-6768
e-mail: qualily@mcs.com - www.qualityligh1ing.com
(72803) Specificalions subject to change wilhout nolice. @2003 Qualily Lightin9
PROJECT WESTON POINTE
E1XTURE TYPE P5 3@120 DEGREES MOUNT
CATALOG NUMBER 123-25-VR-MH400-CL-DB-VOL T-SA
DISTRIBUTIONS
TYPE VR Rectangular Symmetrical (Vert. Lamp)
TYPE F Forward Throw (Horiz. Lamp)
TYPE V Symmetrical (Vert. Lamp)
TYPE VS Square (Vertical Lamp)
TYPE 3 Asymmetrical (Horiz. Lamp)
OROERING EXAMPLE 123-25-VR-HPS-400-CL-DB-120-LA-FD-CL80x360
MH = Std. Metal Halide CL = Convex glass lens
MHP = Pulse Start FL = Flat glass lens
DESIGN DISTRIBUTION HPS MHlMHP LAMP LENS
123-20 3 70/100/150 100/1501175/200' ED-17 FL
F 70/100/150 100/1501175/200' ED-17 FL
V 70/100/150 100/1501175/200' ED-17 FL
123-25 VR 250/400 ED-18 CL
VR 250/400 ED-28 CL or FL
VR 400/450' ED-37 CL
VR 750 BT-37 CL
123-25 VS 250/400 ED-18 CL
VS 250/400 ED-28 CL or FL
VS 400/450' ED-37 CL
VS 750 BT-37 CL
123-25 250/400 ED-18 FL
250 ED-28 FL
400 ED-37 FL
750 BT-37 FL
123-25 F 250/400 ED-18 FL
F 250 ED-28 FL
F 400 ED-37 FL
F 750 BT-37 FL
. Available only in Pulse Start 100,150,200,450 M H P = Pulse Start
REQUIRED CHOICES
FINISH
BK Black
BW White
DB Bronze
SL Silver
FG Gray
CC Custom
VOLTAGES
120
208
240
277
347
480
MOUNTINGS
SA Standard Arm (2.5")
LA Long Arm (13.5")
CWB Cast Wall Bracket
ESF External Slip Fitter
(for 2-3/8" O.D. Pipe)
OPTIONAL CHOICES
Design 123-20/25
ELECTRICAL OPTIONS
FD Single Fusing 120Vl277V
FDD Double Fusing 480V
FDFD Double Fusing 208V/240V
FDC Single Fusing 347V
PCT Photo Cell and Receptacle
OPTICAL OPTIONS
LX Vandal Resistant Shield
(Lexan lens 400W max.)
LIGHT TRESPASS OPTIONS
CL80x360 Internal 800 Vert. x 360' Horiz. Lens Shielding
CL60x135 Internal 600 Vert. x 1350 Horiz. Lens Shielding
HSS House Side Shield (750 Standard) (External)
FL Flat clear glass lens (see ordering information
for availability)
[IJ~[O][Q
CWB
ESF
CL60x135 -Internal
60' Vert. x 135' Horiz.
Lens Shielding
CL80x360 - Internal
80' Vert. x 360' Horiz.
Lens Shielding
There Is no substitute for
A Division of JJI Lighting GIOOpl11110. ,
(judity ~in?N
11500 MELROSE AVE. FRANKLIN PARK, It. 60131 - Phone (847) 451-0040 - FAX (847) 451-6768
e-mail: quality@mcs,com - www.qualitylighting.com
(72803) Specificafions subjecf to change without notice. @2003 Quality Lighting
(~.l
ill
SPECIFICATIONS
H 0 U SIN G Each Design 123 one-piece, reinforced housing shall be oonstructed of heavy-gauge spun aluminum.
the fixture shall be C-UL & UL listed 'suitable for wet locations'.
LEN S F RAM E The heavy-duty cast aluminum lens frame shall be hinged to tile housing w~h twin stainless steel piano hinges.
LEN SAN 0 GAS K E TIN G The flat or oonvex tIlermal and shock resistant glass lens shall be gasketed to tile lens frame w~h exlruded butyl acrylic
tape sealant secured w~h retainer clips. The lens frame shall be gasketed to the housings internal reinforcement ring
w~h silioone impregnated Dacron gasketing.
M 0 U N TIN G Each Design 123 shall be provided w~h a cast aluminum 2.5' long arm for mounting a single fixture or twin fixlures at 180'.
A 13.5" long aluminum arm is supplied for otller mounting oonfigurations.
REF LE eTO R Design 123 shall be available w~h the following reflector systems: 1) Type VR - rectangular distribution;
2) Type F - forward throw distribution; 3) Type V - symmetrical distribution; 4) Type 3 - asymmetrical distribution;
5) Type VS - square vertical lamp. All photometric data shall be certified by an independent testing facil~.
SA LLA STAll CWA ballasts (+10% to -10% lamp power regulation) shall be tray mounted and supplied w~h quick-disoonnects.
Ballasts are rated for -20' F operation. All non CWA ballast shall be HPF.
FIN ISH Polyester powder ooat, electrostatically applied, which is preceded by a five step pre-treatment process including an
iron phosphate priming stage for superior ooating adhesion. This process meets or exceeds all ASTM testing requirements,
including those for 1,000 - hour sa" spray endurance testing.
t
A
tr
B
-1
DIMENSIONS
20' Dia
A 20.00' (508.00 mm)
B 10.SO' (266.00 mm)
25'Dia.
25.00' (635.00 mm)
11.00' (279.40 mm)
EFFECTIVE PROJECTED AREA (EPA)
Size 20' 25'
1 Fixlure 1.40 sq. ft. (.13M2) 2.0 sq. ft. (.19M2)
2 Fixtures 2.80 sq. ft. (.27M2) 4.0 sq. ft. (.38M2)
3 Fixtures 3.85 sq. ft (.37M2) 4.6 sq. ft. (.44M2)
4 Fixtures 4.48 sq. ft. (.43M2) 6.4 sq. ft. (.61 M2)
WEIGHT
20' 36Ibs.(16.33 kgs)
25' 59Ibs.(28.76 kgs)
There Is no substitute for
A Division cIlIiJJI Lighting Group Inc.'
o
ouality Pirflum,~
nnn
11500 MELROSE AVE. FRANKLIN PARK, IL 60131 - Phone (847) 451-0040 - FAX (847) 451-6768
e-mail: quality@mcs.com - www.qualitylightin9.com
(72803) Specifications subject to changa without notice. @2003 auality Lighting
Product Specifications 08210, 08220
P2,P5
valmont ...,
STRUCTURES
ANCIIOIIBOLTS
Anchor Bolts are fabricated from
carbon steel bar conforming to AASHTO
M314 Grade-55 or ASTM F1554
Grade-55. Bolts have an ilL" bend on
one end and are galvanized a minimum
of 12 inches on the threaded end. Four
anchor bolts are provided per pole.
Each anchor bolt is furnished with two
hex nuts and two flat washers.
ANCHOR BASE
The anchor base (base plate) is
fabricated from structural quality hot
rolled carbon steel plate conforming to
ASTM A36. The base plate telescopes
the pole shaft and is circumferentially
welded top and bottom. Please refer
to the charted bolt circles and detail
drawings to determine the type of hole
or slot accommodation made for the
anchor bolt.
POLE SHAFr
The pole shaft conforms to ASTM
A595 Grade-A and is supplied in 11
gauge (0.1196"), 7 gauge (0.1793") 5
gauge (0.2092") or 3 gauge (0.2391 ")
thickness. The pole can be either one-
piece or two piece construction, with a
full length longitudinal high frequency
electric resistance weld. The OS21 0
series is round in cross-section having
a uniform taper of approximately 0.14
inches per foot of length. The OS220
series shaft is square in cross section
having flat sides, radiused comers and
a uniform taper of approximately 0.11
inches per foot of length.
HANDHOLE
The reinforcing handhole rim
consists of either a nominal 3" x 5"
rectangular shaped tubing or 4" x 6.5"
oval shaped pipe material. The 3" x 5"
hand hole is provided with a steel
attachment bar, steel cover, and one
round head machine screw. The 4" x
6.5" hand hole includes two tabs for
mounting a steel cover with hex head
attachment screws. Both hand hole
types are welded in the pole shaft and
are located 1'-6" above the base.
ELEt:JJllCAL _UNO
A nut holder is provided near the
hand hole and includes a .5"-13UNC
hex head bolt and nut.
NUl' COVERS (OPTIONAL}
Nut covers for anchor bolts are
zinc die cast. Each cover is fastened
to the shaft by a 0.25" stainless steel,
self-tapping, hex head screw. Nut covers
are a standard component for the OS21 0
series and are NOT available for the
OS220 series.
RIU BASE COrEll (STANDARD}
The optional full base cover is
fabricated from ASS plastic. Valmont
reserves the right to provide a steel
assembly on some applications
depending upon the finish requirement
and/or pole shaft base diameter. Both
steel and plastic covers are a two-piece
assembly secured together with two
fasteners. A full base cover is a standard
component on the OS220 series.
POLE TOP TENON (STANDARII}
Pole top tenons are fabricated from
structural quality hot rolled carbon
steel with a guaranteed minimum yield
strength of 30,000 psi. A pole top plate
and tenon of weldable grade hot rolled
commercial quality carbon steel is
circumferentially welded to the top of
the pole shaft. This plate provides an
internal weather resistant wiring race-
way into the pole top tenon. Standard
sizes are either 2.38" 0.0. x 4"
long (P2) or 4" 0.0. x 6" long (P4)
steel tubing. See page 1 for other
available sizes.
POLE TOP CAP
A removable cap is available as an
option to be used in conjunction with
drilled shafts for direct luminaire arm
attachment.
STANDARD RNISH
Standard finishes available are
galvanize, prime coat (powder), and
finish coat (powder). For information
regarding the scope and application of
these coatings please refer to page 5.
FJISlfN'NS HARDWARE
All structural fasteners are galva-
nized high strength carbon steel. All
fasteners are galvanized or zinc plated
carbon steel or stainless steel.
29
DES,.
The standards shown in this sec-
tion are designed to withstand dead
loads and theoretical dynamic loads
developed by variable wind speeds,
as charted, with an appropriate gust
factor under the following conditions:
The luminaire(s) and/or mounting
bracket(s) center of gravity, or centroid,
is assumed to be located a maximum of
2'-6" above the pole top. For purposes
of design, effective projected area
(EPA) is considered to be the product
of the actual projected area and the
drag coefficient.
The listed weights include lumi-
naire(s) and/or mounting bracket(s)
and are based on a weight to EPA
ratio of 25 pounds per square foot.
The wind velocities are based on
10 mph increments from 80 mph
through 100 mph (reference wind
map). Standards to be located in
areas of known abnormal conditions
require special consideration. For
example: coastal areas, airports, and
areas of special winds such as the
Chinook type along the eastern slope
of the Rocky Mountains.
Standards are designed for ground
mounted applications. Standards
mounted on structures, such as bridges
and buildings, also necessitate special
consideration requiring Valmont's
recommendation.
Height correction factors and drag
coefficients are applied to the entire
structure. An appropriate safety factor
is maintained based on the minimum
yield strength of the material incorpo-
rated in the standard. Secondary
moments are considered on all designs.
Maximum weight and EPA values
for OS220 products are determined by
analyzing stress from two wind directions
as shown. Oue to the increased area and
reduced section properties, stress levels
across the points generally control the
allowable loads.
Valmont Industries, Inc. reserves
the right to install various, engineer
approved, material hanging accommo-
dations to facilitate the manufacturing
process. If this method is not acceptable,
Valmont Industries, Inc. must be notified
by the customer prior to manufacturing.
BOMPH 90MPH 100MPH
Nominal Shall Pole Base Anchor Bolts w/1.3 Gust w/1.3 Gust wl1.3 Gust
Mounting Base Top Wall Struct. Bolt Circle Max. Max. Max. Max. Max. Max.
Height Designation 0.0. 0.0. Thk. Weight Dia. :!: Square Thk. Dia. x Lngth. x Hk. EPA Weight EPA Weight EPA Weight
(II) Number (in) (in) (ga) (Ibs) (in) (in) (in) (in) (in) (112) (Ibs) (If) (100) (112) (Ibs)
20 **590A200-P2 5.9 3.1 11 140 9.0 .5 10.00 0.88 1.00 x 36 x 4 19.3 482 15.1 377 12.2 305
650A20o-P2 6.5 3.7 11 160 9.5 .5 10.50 0.88 1.oox36x4 24.2 605 19.3 482 15.6 390
**590A250-PL 5.9 2.4 11 155 9.0 .5 10.00 0.88 1.00 x 36 x 4 12.5 312 9.9 247 8.0 200
25 700A250-P2 7.0 3.5 11 200 10.0 .5 10.88 0.88 1.00x36x4 20.3 507 16.2 405 13.1 327
700E250-P2 7.0 3.5 7 280 10.0 .5 10.88 1.00 1.00x36x4 30.5 760 24.0 625 19.8 495
660A300-PL 6.6 2.4 11 200 9.5 .5 10.50 0.88 1.00 x 36 x 4 11.7 292 9.3 232 7.5 187
30 800A300.P2 8.0 3.8 11 265 11.0 .5 11.50 0.88 1.00x36x4 18.9 473 14.9 373 12.0 300
800E300-P2 8.0 3.8 7 380 11.0 .5 11.50 1.25 1.25x42x6 33.5 838 27.0 675 22.0 550
730A350.PL 7.3 2.4 11 250 10.5 .5 11.25 0.88 1.00x36x4 11.2 280 8.9 222 7.1 177
35 850A350.P2 8.5 3.6 11 315 11.5 .5 12.00 1.00 1.00 x 36 x4 18.9 472 15.1 377 12.2 305
950A350.P2 9.5 4.6 11 370 13.0 .5 13.00 1.00 1.00x36x4 23.2 580 18.2 455 14.5 363
782A389-PL 7.8 2.4 11 285 11.0 .5 11.50 0.88 1.00x36x4 10.7 267 8.5 212 6.6 165
39 900A389.P2 9.0 3.6 11 355 12.5 .5 12.38 1.00 1.00x36x4 17.2 430 13.5 338 10.8 270
900E389-P2 9.0 3.6 7 515 12.5 .5 12.38 1.25 1.25 x 42 x 6 28.5 715 23.0 575 19.0 475
45 TOOA450.P2 10.0 3.7 11 450 13.5 .5 14.00 1.00 1.00 x 36 x 4 17.4 435 13.5 338 10.6 265
TOOE450.P2 10.0 3.7 7 650 13.5 .5 14.00 1.25 1.25 x42 x 6 28.5 715 23.0 575 19.0 475
EooE450-P4 11.0 4.7 7 780 15.0 .5 16.50 1.50 1.25 x 42 x 6 35.7 893 28.0 700 22.3 558
TOOA500-P2 10.0 3.0 11 475 13.5 .5 14.00 1.00 1.00 x 36 x 4 13.2 330 10.6 265 8.3 208
TOOE500.P2 10.0 3.0 7 680 13.5 .5 14.00 1.25 1.25x42x6 20.5 512 16.5 412 13.6 340
50 EOOE500.P4 11.0 4.0 7 812 15.0 .5 16.50 1.50 1.25 x 42 x 6 29.9 748 23.5 588 18.6 465
HOOE50o-P4 13.0 6.0 7 1020 17.0 N/A 18.00 1.50 1.50x54x6 50.4 1260 39.7 992 31.4 785
HOOJ500.P4 13.0 6.0 3 1335 17.5 N/A 18.50 1.75 1.75 x84x 6 69.2 1730 55.0 1375 44.2 1105
EOOE550-P4 11.0 3.5 7 & 11 890 15.0 .5 16.50 1.50 1.25x42x6 21.6 540 17.7 442 14.7 367
55 WooE550.P4 12.0 4.5 7 & 11 975 16.0 N/A 17.00 1.50 1.50x54x6 32.2 805 25.9 647 21.1 527
W50455O-P4 12.5 5.2 5&7 1225 16.5 N/A 17.50 1.50 1.50x54x6 43.8 1095 35.0 875 28.6 715
WooE600.P4 12.0 4.0 7&7 1060 16.0 N1A 17.00 1.50 1.50 x 54 x 6 25.9 647 20.7 517 16.8 420
60 HOOE600-P4 13.0 4.8 7 & 11 1075 17.0 N1A 18.00 1.50 1.50 x 54 x 6 30.1 752 24.5 612 20.2 505
W504600.P4 12.5 4.5 5&7 1275 16.5 N/A 17.50 1.50 1.50 x 54 x 6 34.0 850 27.6 690 22.6 565
65 HOOE650.P4 13.0 4.3 7&7 1200 17.0 N/A 18.00 1.50 1.50 x 54 x 6 27.3 682 22.0 550 17.9 447
H004650-P4 13.0 4.3 5&7 1400 17.0 N/A 18.00 1.50 1.50 x 54 x 6 30.8 770 24.8 620 20.4 510
70 HOOE700-P4 13.0 3.6 7&7 1270 17.0 N/A 18.00 1.50 1.50x54x6 20.6 515 16.7 417 13.7 342
H004700.P4 13.0 3.6 5&7 1440 17.0 N/A 18.00 1.50 1.50 x 54 x 6 23.6 590 19.2 480 15.8 395
OS210 NOTES:
1. **3" x 5" nominal handhole . all others 4" x 6.5" nominal.
2. Structure weight is a nominal value which includes the pole shaft and base plate only.
3. Designs showing two shaft gauges indicates structure is provided as a two-piece, field assembled, unit. Heavier gauge is the bottom section.
4. Maximum weight and EPA values are based on top mounted luminaires and/or brackets having a centroid 2'-6" above the nominal mounting height.
30
ff
08210 Round Tapered
valmontV'
STRUCTURES
POLE TOP CAP
SECURED WITH
.5 SET SCREWS
POLE SHArT
POLE MAY BE
DRILLED TO
ACCEPT SIDE
MOUNTED
F'IXTURE IF
REOUIRED.
CAP DETAIL OPTIONAL
1
LENCTH
-L-
TENON
ROUND POLE PLATE
W/W1RE ENTRANCE
HOLE (OEBURRED)
DESIGN
NUMBER
P2
p.t
PI.
o.D~ LENGTH
(tn) (il'l)
.2.575 2 SCHEO 80 .t
.t~000 .5'&- SCHED .to 6
2.400 POLE TOP NA
TENON DETAIL (STANDARD)
BOLT
CIRCLE:
2-PIECE F'ULL BASE COVER
WITH F'ASTENERS
POLE BASE DETAIL
MOUNTING
HEIGHT
REINF'ORCED
HANOHOLE W/CCN(R
AND GROUNDING
.t - ANCHOR BOLTS
WITH THREADED END
GALVANIZED 12" MI~
EACH BOLT F'URNISHED
WITH 2 HEX NUTS AND
2 FLATWASHERS.
05210 POLE DETAIL
31
~,.
i,,'
Ji'..
J
NO
....O()-d.oooOl'l'l"''''..-
~~~r::;r:m ~~~r~~~ ~n~ ewo, 9Lll
SJ....np"lnu"~ foJ"lXl:I t;U!,...!ln .(111''''0 th'!lu.s..,d..~
S~N
NI 'T1V1d'v'J
dD l\iNOISS3.:10dd lNIOd N01S3M
~NI1H~ll ::IllS
90-LO-60
SO-SC-ZL
SO-9L-90
SO-\:L-90
"1IA07 dlllH1dl
C-J
1
-1----\
u.J
/
,.-'
~
!
.
I , , ,I. Jl!r:l !
,
i , , " . . . , .
I i
I I
; ;
,
, i i " I
t. ,I ojrl
i : i ~ . E ~
i i I '! P
'n !
II p. II,I,
I II
llsm d I. H i
H
I . .
ii : ~ i Ii i i
~ c r f ~ t. ;: " f
I if . 0 . . . , . .
Co
I J
II!
!, ,
L
Ll
I' ,
I'
l
L
"0
"'
~ ~I
~I
I