Loading...
HomeMy WebLinkAbout07010007 State Release ~ ~. .. Would you like to reduce your turnaround time? ELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INOIANA AT efile24.7@dhs..in.goy, Or VISIT OUR WEB SITE AT www.in.gov/dhs/branches/planreview/index.html Project numtief-----'-----~-T Release date ------: CONSTRUCTION DESIGN RELEASE State Form 41191 (R9/S-98) Report Printed on: January 8, 2007 323122 Construction type V-B 01/08/07 : Occupancy classification TOWNHOUSE, M "i'- ,,- INDIANA 02 ~oo~gQPO Scope of release i ARCH ELEC FDN I PLUM STR ~Type of release Standard Project name I Monon and Main Bldg 3 MECH Indiana Department of Homeland Security DIVISION OF FIRE SAFETY I PLAN REVIEW 402 W. Washington St., Room E245 Indianapolis, IN 46204 Available At Your Locallleent:e Branch To: Owner I Architect I Engineer Bruce Gunstra Builders Inc Robert Grove 18369 Street address bl8383 Craig St Suite 100 312 - 336 W. Main SI Indianapolis IN 46250 I City----~---.-~-TC-ounty ______[ 'I CARMEL I HAMIL TON ,I ax &.8'"'"811: 3175959095, smosher@gunstrabuilders.com ~ The-'plans, specifications and application submitted for theabove-refere"nced proJecthiiive-beenreVfewea-for compliance with the applicable rules of the Fire Prevention and Building Safety Commission. The project is released for construction subject to, but not necessarily limited to, the conditions Iisted"below."THIS'IS NOT ABUilDING PERMIT. All required local permits and licenses must be obtained prior to beginning construction work. An construction work must be in full compliance with aU applicable State rules. Any changes in the released plans and/or specifications must be filed with and released by this Office before any work is altered. Thfs refease may be. suspended or revoked if it is determined to be issued in error, in violation of any rules of the Commission or if it is based on incorrect or insufficient information. This release shall expire by limitation, and become null and void. if the work authorized is not commenced within one (1)year from the above, date. " CONDITIONS: ',' SUPPORT HOOSIER SAFETY Note :(A 1A & A 1B): In accordance;wi~ the affidavit sworn under penalties of perjury in the application for construction design release the plans and specifications filed In conjunctl~n with this project shall comply with all of the applicable rules and laws of Fire Prevention and Building Safety yommission. Providing false information constitutes an act of perjury, which is a Class D felony punishable by a prison term and a fine up to $10,000. In accordance with Section 19 of the General Administrative Rules (675 lAC 12-6-19) a complete set of plans and specifications that conform exactly to the design that was released by the office of the state building commissioner shall be maintained on the construction jobsite as well as a copy of the design release. This Release includes Building 3 Townhouses and Lot 3 Retail Space. 1 D -. This project has been reviewed under the 2003 Residential Code. . , 1D0301A - Without a design, the minimum snow loading for roof design shall be in accordance with Section R301, IRC (675 lAC 14-4.3). 1D0301B - The design of townhouses shall be in accordance with the seismic positions of Section R301.2.2 (675 lAC 14-4.3). 100309A - Permitted openings between the garage and the residence shall be equipped solid wood, or solid honeycomb core steel doors not less than 1 3/8 inches thick or 20-minute fire-rated doors in accordance with Section R303.1, IRC (675 lAC 14-4.3). 100314B - All stairway steps shall have a maximum rise of 9-1/4 inches and an a minimum run of 9 inches in accordance with Section R311.5.3.1 and R311.5.3.2, IRC (675 lAC 14-4.3). 1D0321C - Through penetrations of fire-resistive wall or floor/ceiling assemblies shall be in accordance with Section R321.3.1. IRC (675 lAC 14-4.3). 1D0405A - Drains shall be provided around all foundations that enciose habitable or usable spaces located below grade in accordance with Section R405. IRC (675 lAC 14-4.3). 101501A - Clothes dryer exhaust shall convey moisture to and terminated outdoors in accordance with Section M1501, IRC (675 lAC 14-4.3). 1D1502A - Vented range hoods shall discharge to the outdoors in accordance with Section M1502.1, IRC (675 lAC 14-4.3). Page 1/2 : '" . Would you like to reduce your turnaround time? ELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INDIANA AT efile24.7@dhs..in.gov, Or VISIT OUR WEB SITE AT www.in.gov/dhs/branches/plan review/index.hlml 1018030 - Chimney and vent connection shall have minimum clearances in combustibles in accordance with Section M1803.3.4, IRC (675 lAC 14-4.3). 102400 - Fuel gas piping shall be in accordance with Chapter 24, IRC (675 lAC 14-4.3). All Structural members and manufactured wood trusses shall be designed, constructed and installed in accordance with 2003 IBC, Chapter 16. The wall between the Townhouse 3A and the Lease area requires a 2 hour fire separation and door openings will require an 1.5 hr fire rating. 4G0603AB This project release does not include the completion of tenant spaces. However, previously submitted "typical" tenant layouts or work exempted by the General Administrative Rules does not require a remodel release in accordance with 675 lAC 12-6-3 and 4. Lot 3A Lease Space The assigned Addresses are as follows: 3A - 336 W. Main St 3B - 332 W. Main 3C - 328 W. Main 3D - 324 W. Main 3E - 320 W. Main 3F - 316 W. Main 3G - 312 W. Main Please be advised that itan administrative review of this acfionis desired, a written petition for review must be Rlad at the above address with the Fire Prevention and Building Safety Commission identifying the matter for which a review is sought no later than eighteen (18) days from the above. stated date, unless the eighteenth day falls ona Saturday, a Sunday; a legal holiday under State statute. or a day in which the Department of Fire and Building Services is closed during normal business hours. In the tatter case: the filing deadline will be the first working day thereafter, If you choose to petition, and the before-mentioned procedures are followed, your petition for review will be granted, and an administrative proceeding will be conducted by an administrative law judge of the Fire Prevention and Building Safety Commission" If a petition for review is not filed, this Order will be final, and you must comply"with its requirements, , ... I--F'I dB - =r;;. Cd "--'~"'----ffi.--:--I - 1 ~,,--.- --"'- co.. - -- - I Ie Y 0 e reVl8WO Icta ~. ... MARYF~OS~ti___ .tJ~d~~~d_ I Address (name,title-of local official,street,city,state and lIP code -;.r~ ~~~~N~.~~~~ N.ITY_S ERVICE State Fire Marshal (,7 o~ g~~~~tC~~~A1~3;( V {?' ,~tlJ#- Fax & e.mall: 317571'2499, 'blanchard canneUn. ov Page 2/2 . Indiana Department of Homeland Security DIVISION OF FIRE SAFETY / PLAN REVIEW .a CONSTRUCTION DESIGN RELEASE . ~i'$""" ~~ State Form 41191 (R9/5-9S) l=I~.~ "'- 2 '(f . . Report Pnnted on December 18, 2006 ., ~ . ." INDIANA --o-i' ~ F 0000 Would you like to reduce your turnaround time? ELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INDIANA AT eflle24~7@dhs..in.gov. Or VISIT OUR WEB SITE AT www.in.gov/dhs/branches/planreviewllndex.html Project number ------r Release date I 12/18/06 -I Occupancy classification L~_ 323122 Construction type 402 W. Washington St., Room E245 S Type 0 release Indianapol is, IN 46204 HOOSIER SAFETY FDN i I Available At Your Local Licence Branch Project name - I To: Owner I Architect I Engineer SUPPORT HOOSIER SAFETY Monon and Main 81dg 3 Bruce Gunstra Builders Inc Robert Grove 18369 Street address 8383 Craig St Suite 100 Rangeline Indianapolis IN 46250 City I County -ax & e-mail: 3175959095, smosher@gunstrabuilders.com CARMEL HAMILTON I Scope of release I FDN 1----------------- f The plans, specifications and application submitted for the above referenced project have been reviewed for compliance with the applicable rules of the Fire Prevention and Building Safety Commission. The project is released for construction subject to, but not necessarily limited to, the conditions listed beIOW.THIS'IS NOTABUILDING'PERMIT.^AlIrequired'local permits and licenses must be obtained prior to beginning construction work. All construction work must be in full compliance with all applicable State rules. Any changes in the released plans andlor specifications must be filed with and released by this Office before any work is altered. This release may be suspended or revoked if it is determined to be issued in error, in violation . of any rules of the Commission or if it is based on incorrect or insufficient information. This release shall expire by limitation, and become null and void, if the work authorized is not commenced within one (1) year from the above date. CONDITIONS: Note :(A 1A & A 1 B): In accordance;with the affidavit sworn under penalties of perjury in the application for construction design release the plans and specifications filed in conjunctklliwith this project shall comply with all of the applicable rules and laws of Fire Prevention and Building Safety <?ommission. Providing f~ls~ infonTlatlon constitutes an act of pe~ury, which is a Class 0 felony punishable by a prison term and a fine up to $10,000. In accordance with Section 19 ofthe General Administrative Rules (675 lAC 12-6~19) a complete set of plans and specifications that conform exactly to the design that was released by the office of the state building commissioner shall be maintained on the construction jobsite as well as a copy of the design release. A1AA This foundation release will pennit work to grade only. Any corrective work found to be necessary . as a1resul\.of plan review, subsequent to the issuance of the foundation release shall be done at the ~pplicant's expense in accordance with Section 675 lAC 12-6-14. . ,NOTE: Conditions will be noted on the Construction Design Release. A1AB Please,be'advised that jf an administrative review of this action is desired, a written petition for review must be filed at the above address with the FirePrevention and Building Safety Commission identifying the matter for which a review is sought no later than eighteen (18) days from the above ~ stated date, unless the eighteenth day falls on a Saturday, a Sunday, a legal holiday under State statute, or a day in which the Department of Fire and Building Services is closed during normal business hours. In the latter case, the filing deadline will be the first working day thereafter. If you chbOse-to'petitiori; and-the befor'e~rneritioned procedures are followed, your petition for review will be granted, and an administrative proceeding will be conducted by an administrative law judge of the Fire Prevention and Building Safety Commission. If 8 petition for review is not filed, this Order will be final, and you must comply with its requirements. Filed By Code review official Code Enforcement & Plan Review Branch Directo-r--~-----~-I State Fire Marshal ~~d/S~ V1l'O~ MARILYN LOVE _________~_.__._______J Address (name,title of local official,street,city,state and ZIP code I DEPT OF COMMUNITY SERVICE JIM BLANCHARD LONE CIVIC SQUARE CARMEL, IN 46032 Fax & e~mail: 3175712499, iblanchardl'i'i'lcarmeUn....ov Page 1/1