HomeMy WebLinkAboutFloor PlansA2.01 2 A2.013 A2.014 A2.01 1 GFEDCB J KHIA L 3 3 1 1 2 2 6 5 7 4 28' - 0"24' - 0"52' - 0"30' - 0"391 SF 101 MECH 819 SF 102 SHOP 2,016 SF 103 GARAGE 362 SF 104 OFFICE 63 SF 105 BATH 199 SF 106 BEDROOM244 SF 107 KITCHEN 885 SF 108 GATHERING 7 SF 109 CLOSET 30 SF 110 BATH 29 SF 111 STORAGE 29 SF 112 STORAGE 305 SF 113 HALLWAY 670 SF 114 PATIO 24' - 1"1 A3.01 138' - 6" -- - -2' - 0"2' - 0"18' - 0"28' - 0"24' - 0"82' - 0"1' - 3"12' - 0"12' - 0"12' - 0"12' - 0"12' - 0"12' - 0"12' - 0"12' - 0"4' - 0"12' - 0"12' - 0"12' - 0"1' - 3" 37' - 0"51' - 8"38' - 0"11' - 10" 28 3 A3.01 2 A3.01 1 A3.02 2 A3.02 /1A1.01-A2/1A1.01-A1 /1A1.01-A2/1A1.01-A12' - 5 1/2"25' - 0"49' - 6"76' - 11 1/2"GENERAL PLAN NOTES 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. DO NOT SCALE DRAWINGS. DIMENSIONS ARE TAKEN TO FACE OF STUD, FACE OF CONCRETE, FACE OF MASONRY, FACE OF EXISTING FINISHES, AND COLUMN LINES UNLESS SPECIFICALLY NOTED OTHERWISE. FINISHED (FIN, FD) OR CLEAR (CLR) DIMENSIONS INDICATE FINISH SURFACE TO FINISH SURFACE SPANS BETWEEN WALLS OR FROM FINISH SURFACE OF WALL TO LATCH/HINGE OF ADJACENT DOOR OR CENTERLINE OF PLUMBING FIXTURES. LETTER DESIGNATIONS WITHIN A DIMENSION STRING (SUCH AS "A", "B", "C" AND SO ON) INDICATE THAT THE DIMENSION IS TO BE FIELD DETERMINED AND IT IS TO BE EQUAL TO OTHER DIMENSIONS OF THE SAME LETTER THROUGHOUT THAT SPECIFIC DRAWING SHEET, BUT NOT TO THE SAME DESIGNATION ON OTHER DRAWING SHEETS. USE OF "EQUAL" OR "EQ" WITHIN A DIMENSION STRING INDICATES A DIMENSION THAT IS TO BE EQUAL ONLY RELATIVE TO OTHER EQUAL CALLOUTS ON THE SAME DIMENSION STRING IN WHICH IT APPEARS. DIMENSIONS CALLED OUT AS EQUAL ON TWO DIFFERENT DIMENSION STRINGS ARE NOT NECESSARILY EQUAL TO EACH OTHER. ALL DESIGN TEAM DRAWINGS SHALL BE USED TO LOCATE BUILDING ELEMENTS. CONTACT THE ARCHITECT WITH CONFLICTS, DISCREPANCIES, AND OMISSIONS PRIOR TO COMMENCEMENT OF WORK. WRITTEN DOCUMENTATION SHALL BE PROVIDED BY THE CONTRACTOR REGARDING SUCH ITEMS. STRUCTURAL, MECHANICAL, ELECTRICAL, PLUMBING, LOW VOLTAGE AND FOOD SERVICE ELEMENTS ARE SHOWN FOR REFERENCE ONLY. VERIFY EACH ELEMENT WITH THE ASSOCIATED ENGINEER'S DRAWINGS. COORDINATE CONFLICTS WITH THE ARCHITECT. FLOORS SHALL SLOPE TO FLOOR DRAINS. SLOPES SHALL COMPLY WITH ADA ACCESSIBILITY GUIDELINES. WALL FRAMING, INSULATION, SHEATHING, AND FINISHES SHALL EXTEND FROM THE TOP OF SLAB TIGHT TO THE UNDERSIDE OF THE DECK ABOVE UNLESS NOTED OTHERWISE. PARTIAL HEIGHT WALLS ARE NOTED WITH TOP OF WALL ELEVATIONS. REFER TO SPECIFICATIONS FOR EACH ITEM REPRESENTED WITHIN THE DRAWING SET. STUD WALL CONTRACTOR SHALL PROVIDE IN-WALL BLOCKING FOR WALL MOUNTED OWNER PROVIDED AND CONTRACTOR PROVIDED ITEMS REPRESENTED WITHIN THE DRAWINGS AND SPECIFICATIONS. GENERAL CONTRACTOR TO PROVIDE BACKER ROD AND SEALANT OF A TYPE APPROPRIATE TO EACH CONDITION, BETWEEN MATERIALS BOTH SIMILAR AND DISSIMILAR THROUGHOUT THE INTERIOR AND EXTERIOR OF THE BUILDING. (COLORS TO BE SELECTED BY ARCHITECT) EACH EXTERIOR STUD WALL ACROSS THE ENTIRETY OF THE BUILDING IS TO RECEIVE A MINIMUM R-19 BATT INSULATION. SEE STRUCTURAL DRAWINGS FOR INFORMATION REGARDING CMU AND CAST-IN-PLACE WALLS. NOT F O R CONS T R U C TI O N See Drawing CERTIFICATION Checked By: Scale: Issue Date: Drawn By: Project No.: 626 North Illinois Street Indianapolis, Indiana 46204 Phone: (317) 635-5030 Website: www.browningday.com Owner 1/12/2024 2:32:39 PM\\bdmd.local\uem\UserShare\erheinheimer\Documents\23022 - Bush Six Point_Shop Residence (R23)_erheinheimer.rvtA1.01 1st Floor Key Plan 23022 Author Checker Month Day, 2023 Bush Six Points - Shop Residence 13280 Six Points Rd. Carmel, Indiana 46032 Design Development 12826 Norfolk Circle Carmel, IN 46204 Rob Bush Three Parkwood Crossing Suite 175, Indianapolis, IN 46240 Phone: (317) 580-0402 Website: www.o-n.com O'Donnel & Naccarato Structural Engineer 9711 Valparaiso Dr # A Munster, IN 46321 Phone:(219) 924-8400 Website: www.milliesengineeringgroup.com Millies Engineering Group MEP Engineer 958 E Washington St Suite 100 Indianapolis, IN 4620 Phone: (317) 616-0177 Website: www.landworxeng.com LandWorx Engineering Civil Engineer REVISION SCHEDULE Rev. #Revision Description Issue Date A1.01 1/8" = 1'-0" Floor Plan11st Floor Plan NORTH UP UP GENERAL PLAN NOTES 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. DO NOT SCALE DRAWINGS. DIMENSIONS ARE TAKEN TO FACE OF STUD, FACE OF CONCRETE, FACE OF MASONRY, FACE OF EXISTING FINISHES, AND COLUMN LINES UNLESS SPECIFICALLY NOTED OTHERWISE. FINISHED (FIN, FD) OR CLEAR (CLR) DIMENSIONS INDICATE FINISH SURFACE TO FINISH SURFACE SPANS BETWEEN WALLS OR FROM FINISH SURFACE OF WALL TO LATCH/HINGE OF ADJACENT DOOR OR CENTERLINE OF PLUMBING FIXTURES. LETTER DESIGNATIONS WITHIN A DIMENSION STRING (SUCH AS "A", "B", "C" AND SO ON) INDICATE THAT THE DIMENSION IS TO BE FIELD DETERMINED AND IT IS TO BE EQUAL TO OTHER DIMENSIONS OF THE SAME LETTER THROUGHOUT THAT SPECIFIC DRAWING SHEET, BUT NOT TO THE SAME DESIGNATION ON OTHER DRAWING SHEETS. USE OF "EQUAL" OR "EQ" WITHIN A DIMENSION STRING INDICATES A DIMENSION THAT IS TO BE EQUAL ONLY RELATIVE TO OTHER EQUAL CALLOUTS ON THE SAME DIMENSION STRING IN WHICH IT APPEARS. DIMENSIONS CALLED OUT AS EQUAL ON TWO DIFFERENT DIMENSION STRINGS ARE NOT NECESSARILY EQUAL TO EACH OTHER. ALL DESIGN TEAM DRAWINGS SHALL BE USED TO LOCATE BUILDING ELEMENTS. CONTACT THE ARCHITECT WITH CONFLICTS, DISCREPANCIES, AND OMISSIONS PRIOR TO COMMENCEMENT OF WORK. WRITTEN DOCUMENTATION SHALL BE PROVIDED BY THE CONTRACTOR REGARDING SUCH ITEMS. STRUCTURAL, MECHANICAL, ELECTRICAL, PLUMBING, LOW VOLTAGE AND FOOD SERVICE ELEMENTS ARE SHOWN FOR REFERENCE ONLY. VERIFY EACH ELEMENT WITH THE ASSOCIATED ENGINEER'S DRAWINGS. COORDINATE CONFLICTS WITH THE ARCHITECT. FLOORS SHALL SLOPE TO FLOOR DRAINS. SLOPES SHALL COMPLY WITH ADA ACCESSIBILITY GUIDELINES. WALL FRAMING, INSULATION, SHEATHING, AND FINISHES SHALL EXTEND FROM THE TOP OF SLAB TIGHT TO THE UNDERSIDE OF THE DECK ABOVE UNLESS NOTED OTHERWISE. PARTIAL HEIGHT WALLS ARE NOTED WITH TOP OF WALL ELEVATIONS. REFER TO SPECIFICATIONS FOR EACH ITEM REPRESENTED WITHIN THE DRAWING SET. STUD WALL CONTRACTOR SHALL PROVIDE IN-WALL BLOCKING FOR WALL MOUNTED OWNER PROVIDED AND CONTRACTOR PROVIDED ITEMS REPRESENTED WITHIN THE DRAWINGS AND SPECIFICATIONS. GENERAL CONTRACTOR TO PROVIDE BACKER ROD AND SEALANT OF A TYPE APPROPRIATE TO EACH CONDITION, BETWEEN MATERIALS BOTH SIMILAR AND DISSIMILAR THROUGHOUT THE INTERIOR AND EXTERIOR OF THE BUILDING. (COLORS TO BE SELECTED BY ARCHITECT) EACH EXTERIOR STUD WALL ACROSS THE ENTIRETY OF THE BUILDING IS TO RECEIVE A MINIMUM R-19 BATT INSULATION. SEE STRUCTURAL DRAWINGS FOR INFORMATION REGARDING CMU AND CAST-IN-PLACE WALLS. W1 WW B 1 WINDOW TAG: SEE A8-SERIES DRAWINGS [ S: 101A ]SIGN TAG: SEE SIGNAGE PACKAGE WALL TAG: SEE SHEET A0.10 and A0.11 FOR WALL TYPE AND FIRE RATING REQUIREMENTS. SEE A4 SERIES DRAWINGS FOR WALL FINISHES. CODED NOTES OF VARYING TYPES: SEE SCHEDULES ON THIS SHEET DOOR TAG: SEE SHEET A8-SERIES DRAWINGS. SYMBOL LEGEND 1 PLAN 101-A A2.01 1 A2.021A2.022 A2.01 2 A F 1234 C D B E 2 A3.01 1 A3.02 1 A3.01 2 A3.02 108 STORAGE 105 GATHERING 106 KITCHEN 103 DRESSING 104 1/2 BATH 102 MECH 101 ENTRY 107 GYM 101-A STORAGE 101-B STORAGE 105-A STORAGE MATCHLINE/1A1.01-A1 /1A1.01-A2 PICKLEBALL COURT AREA PICKLEBALL COURT AREA PICKLEBALL COURT AREAPICKLEBALL COURT AREA 30'X60' (MIN.) PLAYING SURFACE 34'X64' (PREFERED) 20'X44' PICKLEBALL COURT 30'X60' (MIN.) PLAYING SURFACE 34'X64' (PREFERED) 20'X44' PICKLEBALL COURT COLUMNS COLUMNS 6' - 0"1' - 4"20' - 8"1' - 6"16' - 0"34' - 0"17' - 6"12' - 0"109' - 0"6' - 0"2' - 0"10' - 0"8' - 4"24' - 8"18' - 4"2' - 0"6' - 0" 77' - 4"6' - 0"1' - 4"20' - 8"1' - 6"16' - 0"34' - 0"17' - 6"10' - 11 1/4"6' - 0"15' - 2"35' - 0"15' - 2"6' - 0" A0.6 A0.2 A2.01 1 A2.021A2.022 A2.01 2 A F 1 2 3 4 C D B E 2 A3.01 1 A3.02 1 A3.01 2 A3.02 204 ROOFTOP PATIO WEST 202 BEDROOM 201 FAMIY ROOM OPEN TO BELLOW MATCHLINE /2 A1.01-A2 1 A1.04-R2 2 A1.04-R2 203 FULL BATH1' - 6"22' - 0"40' - 2 3/4" A0.6 A0.2 208 STAIRWELL 207 ROOFTOP PATIO EAST NOT F O R CONS T R U C TI O N See Drawing CERTIFICATION Checked By: Scale: Issue Date: Drawn By: Project No.: 626 North Illinois Street Indianapolis, Indiana 46204 Phone: (317) 635-5030 Website: www.browningday.com Owner 1/12/2024 1:42:01 PM\\bdmd.local\uem\UserShare\erheinheimer\Documents\23022 - Bush Six Point_Pickleball (R23)_erheinheimer.rvtA1.01 Key Plans 23022 ER AF December 28, 2023 Bush Six Points - Pickleball Residence 13280 Six Points Rd. Carmel, Indiana 46032 Design Development 12826 Norfolk Circle Carmel, IN 46204 Rob Bush Three Parkwood Crossing Suite 175, Indianapolis, IN 46240 Phone: (317) 580-0402 Website: www.o-n.com O'Donnel & Naccarato Structural Engineer 9711 Valparaiso Dr # A Munster, IN 46321 Phone:(219) 924-8400 Website: www.milliesengineeringgroup.com Millies Engineering Group MEP Engineer 958 E Washington St Suite 100 Indianapolis, IN 4620 Phone: (317) 616-0177 Website: www.landworxeng.com LandWorx Engineering Civil Engineer CODED PLAN NOTES MARK NOTE 1 ALIGN FINISH FACE 2 4'x6' WALL OPENING, DOOR ON GYM SIDE TO COVER OPENING WHEN NOT IN USE. 3 GUARDRAIL 4 GAS FIREPLACE REVISION SCHEDULE Rev. #Revision Description Issue Date NORTHA1.01 1/8" = 1'-0" Floor Plan1First Floor - Key Plan NORTH A1.01 1/8" = 1'-0" Floor Plan22nd Floor - Key Plan 1/8" = 1'-0" 5'10'15'0' 1/8" = 1'-0" 5'10'15'0'