HomeMy WebLinkAbout06070033 Correspondence (2)
PAU L r:: ESTRIDGE
/34Lct S"'.U -1J"7
Jim Ochs
Building Inspector/Plan Review
Department of Community Services
Carmel City Hall
One Civic Square
Carmel, IN 46032
1/17/07
Greg Cradick
Architect
The Estridge Companies
14300 Clay Terrace Blvd.
Carmel, IN 46033
Jim,
1ms letter is in response to your comments from our meeting on 1/12/07 at lot 40TThe
Village of West Clay 1943 Broughton Street Carmel, Indiana 46032
Issue #1
Bearing wall to Left of fireplace has no joist or wall for direct bearing transfer to below.
1ms also a plumbing in wall with greater than 50% of the wall plate cut.
Resolution
Stad wall added directly below to bottom of floor system. Then 2x4 blocking on top of :
stad wall to bottom side of floor deck was added. 1ms allows for direct transfer of loads
to thickened slab foundation.
The plumbing locations received a 16" metal plumbing strap.
Issue #2
To the right of the fireplace there is a point load from above that bears on 2 engineered
joists not per manufacturers installation requirements.
Resolution
At stair band slid a 2Xl 0 and Y, OSB between webs of joists to fill the cavity. Then we
nailed through the flanges with a nailing pattern to manufacturers requirements.
1 Gregory H. Cradick ,ARB #19900118 State of Indiana, have inspected and agree that
these structural items are repaired and the homes in good structural cond,ition. Please call
. . ~~Il~\UU ;nUlla8@;
me at 815-2507 for further informatIon. ."." ~'{ H. C;:'!,,-
~ 00 . . ~vt"~
$~ So",,", ~~.
Thanks for you help and education on these matters. j (t rvf>\ '.....<<'0 '* \. __ -
:: ~ No. . ~
- ~ AR19.9.00118 !i1i
Best regards, ~ STAl'E' OF Ii
'::. @/i:
.-., G Ift'O'1 ,-,~ !il-
. ~ ~'V, ~~ ~
Gregory H. Cradlck ~~_ .<' ...~lle.gQaO r~ '!t.$
-'. -~H 1'2-V,"
14300 CLAY TERRACE BOULEVARD, SUITE 200 . CARMEL, INDIANA 46032. P 317.846.7311 F 317.5'ir204iflftiil,o\~\l}'GECUSTOMGALLERIES.COM