Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Muse at The Corner-ADLS-PZ-2023-00174 Sign Package
CONCEPTUAL, SUBJECT TO CHANGE, FOR ILLUSTRATION PURPOSES ONLY 02/23/21 EXTERIOR SIGNAGE The Corner - Carmel, IN 2/12/2024 11.36' 36 ft 36 ft 21.33 ft 16.9 ft Canopy Mounted Signs: 14’ and less = 90% of the length x 24” tall 14’ and more = 70% of the length x 24” tall Flag Mounted Tenant Pucks: (5sf) 9’ to the bottom min. Wall Signs Max 300sf: Between Spandrel. 85% Width x 70% Height 10.2 ft 44.6"31' 314.5"31"314.5"31"142"24"2'33' TB TB TB TB TB TB TB24"24"24"130"130"130" TC TC TC TW TW TC TC 24"2/12/2024 MATERIAL LEGENDELEVATION KEY NOTES BLDG A L 01.4 +821' -10 7/16" BLDG A L 05 +871' -10 1/16" BLDG A TRUSS BEARING +880'-11 3/16" BLDG A L 02 +839' -10 7/16" BLDG A L 03 +850' -6 5/16" BLDG A L 04 +861' -2 3/16" 3.8MATCHLINEREFER TO7 / A2023.3 3.4 2.2 2.1 3.11 2.1 2.1 3.12 2.2 BLDG A L 01.3 +821' -3 19/32" 25 A305 7'-0"9'-1 1/8"10'-7 7/8"10'-7 7/8"10'-7 7/8"18'-6 13/16"BREEZEWAY OPEN BEYOND ANGLED ELEV. FUTURE RETAIL UNIT B4 FUTURE RETAIL UNIT S2 FUTURE RETAIL UNIT A2f FUTURE RETAIL UNIT A2g FUTURE RETAIL UNIT B1e alt3 UNIT A1 alt3 FUTURE RETAIL UNIT B1f FUTURE RETAIL UNIT B3 3.13 3.10 3.10 3.15 3.14 3.1 3.2 3.10 3.9 2.2 3.11 4.4 3.3 3.14 2.4 BRONZE WINDOWS AND DOORS WHITE WINDOWS; RELAXED KHAKI DOORS WHITE WINDOWS; ALABASTER DOORS WHITE WINDOWS; BRONZE DOORS WHITE WINDOWS; TOQUE WHITE DOORS BRONZE WINDOWS AND DOORS E.J.E.J.E.J.E.J.E.J.E.J. E.J.E.J. S I G N A G E S I G N A G E SIGNAGE 1 11 3 BLDG A L 01.4 +821' -10 7/16" BLDG A L 05 +871' -10 1/16" BLDG A TRUSS BEARING +880'-11 3/16" BLDG A L 02 +839'-10 7/16" BLDG A L 03 +850' -6 5/16" BLDG A L 04 +861' -2 3/16" 2.1 4.4 2.1 2.1 3.12 18'-0"10'-7 7/8"10'-7 7/8"10'-7 7/8"9'-1 1/8"FUTURE RETAIL UNIT A1e CORRIDOR 5'-3" FUTURE RETAIL UNIT B3 3.9 3.14 3.2 3.5 2.2 BRONZE WINDOWS E.J.E.J.E.J.E.J. SYMBOL MATERIAL/FINISH COLOR STYLE ROOF BRICK / STONE 1.1 1.2 1.3 2.1 2.2 2.3 SIDING / TRIM 3.1 3.2 3.3 METAL 4.1 4.2 4.3 COMPOSITION SHINGLES METAL ROOFING CAST STONE BRICK BRICK FIBER CEMENT LAP SIDING FIBER CEMENT LAP SIDING METAL RAILING METAL LOUVER DARK BRONZE TPO MEMBRANE WHITE ALUMINUM STOREFRONT ROMAN RED FLAT SET LIGHT BROWN WIRECUT 3.4 FIBER CEMENT TRIM 2.4 BRICK RIPLEY ESTATE GRAY FIBER CEMENT PANELING 7" EXPOSURE 7" EXPOSURE 4.4 STEEL CANOPY 0.0 4.5 ALUMINUM DOWNSPOUT 4" DIAMETER, UNO WITH COLLECTOR HEAD MERIDIAN BRICK MERIDIAN BRICK BRAMPTON BRICK OLIVE BUFF CUSTOM CAST STONE 3.5 FIBER CEMENT PANELING 3.6 FIBER CEMENT PANELING 3.7 FIBER CEMENT LAP SIDING 3.8 FIBER CEMENT LAP SIDING 3.9 FIBER CEMENT TRIM 3.10 FIBER CEMENT PANELING URBANE BRONZE SW 7048 FELTED WOOL SW 9171 DORIAN GRAY SW 7017 TOQUE WHITE SW 7003 THUNDEROUS SW 6201 RIVERWAY SW 6222 RELAXED KHAKI SW 6149 SAWDUST SW 6158 RELAXED KHAKI SW 6149 ALABASTER SW 7008 3.11 FIBER CEMENT LAP SIDING PORPOISE SW 7047 3.12 FIBER CEMENT LAP SIDING ANONYMOUS SW 7046 FIBER CEMENT TRIM URBANE BRONZE SW 7048 3.13 FIBER CEMENT TRIM DORIAN GRAY SW 7017 3.14 4" EXPOSURE 7" EXPOSURE 7" EXPOSURE 7" EXPOSURE FIBER CEMENT LAP SIDING TOQUE WHITE SW 7003 7" EXPOSURE 3.15 URBANE BRONZE URBANE BRONZE BRONZE/ WHITE BLACK URBANE BRONZE MORTAR COLOR FOR ALL BRICK COLORS TO BE MORTAMIX SHELBY TAN OR APPROVED EQUAL. 1 EXTERIOR SIGNAGE -PROVIDE 3/4" TREATED PLYWOOD BLOCKING FOR SIGNAGE. ATTACH TO GYP SHEATHING, G.C. TO COORDINATE EXACT LOCATIONS W/ OWNER/ TENANT. 2 EXTERIOR SIGNAGE -MOUNTED TO AWNING, G.C. TO COORDINATE EXACT LOCATIONS W/ OWNER/ TENANT. BLDG A L 01.4 +821' -10 7/16" BLDG A L 02 +839'-10 7/16" 2.1 3.5 2.4 4.3 22 A525 Sim 2.4 BLDG A L 02 +839'-10 7/16" BLDG A L 01.3 +821' -3 19/32" CLCLCL 10'-8 1/2"10'-8 1/2"8'-0"2.1 3.5 2.4 2.4 3.10 4.3 50 South B.B. King Blvd. Suite 600 Memphis, TN 38103 901.521.1440 Drawing Name: Client: Drawn By: Checked By: Project Name: Seal ©2020 LRK Inc. Drawings, written material, and design concepts shall not be used or reproduced in whole or part in any form or format without prior written consent of LRK Inc. Do not scale drawings. Use given dimensions only. If not shown, verify correct dimensions with the Architect. Contractor shall check and verify all dimensions and conditions at job site.11/30/2021 4:51:27 PM C:\Revit Projects\18066-Corner Carmel-CENTRAL-19_chaley.rvtLRK Project Number: 01.18066.00 A203 EXTERIOR ELEVATIONS - BUILDING A The Corner Carmel, IN VWB DSPThe Corner Carmel, IN • 01.18066.00 1685 E. 116th Street, Carmel, IN SCALE: 1/8" = 1'-0" 25 NORTH ELEVATION - BUILDING A SCALE: 1/8" = 1'-0" 7 WEST ELEVATION - BUILDING A SCALE: 1/8" = 1'-0" 4 NORTH BREEZEWAY - BUILDING A SCALE: 1/8" = 1'-0" 10 NORTH BREEZEWAY - BUILDING A 06.16.21 Permit Set A 07.15.21 Addendum A B 08.20.21 IFC Set C 09.01.21 IFC Set 3 11.30.21 ASI 01 A525 A305A202 14.8 ft 14.8 ft 36.9' Canopy Mounted Signs: 14’ and less = 90% of the length x 24” tall 14’ and more = 70% of the length x 24” tall Flag Mounted Tenant Pucks: (5sf) 9’ to the bottom min. Wall Signs Max 300sf: Between Spandrel. 85% Width x 70% Height 202.5”11.5 ft 23.7' 20'31"20' 204"113"25.67 ft 113"36”32.32' 329"31"201.60" TB TB TB TB TB TBTB TB TB TW TW TW TW TWTC TC TC 70% of Spandrel Height = 37.8” 85% of Spandrel Length = 61.2” 10% Leeway Allowance for Architectural Elements that hinder visiblity 96"24"2/12/2024 18 ft24 ft24 ft \\server01\Company\Common\A - Sales\Adam\Buckingham Management\The Corner\Files From Client\Drawings 27.1 ft Canopy Mounted Signs: 14’ and less = 90% of the length x 24” tall 14’ and more = 70% of the length x 24” tall Flag Mounted Tenant Pucks: (5sf) 9’ to the bottom min. Wall Signs Max 300sf: Between Spandrel. 85% Width x 70% Height 88"150.6"140.6"140.5"197.6" 253.4" TB TB TB TB TB TBTW TW TW TW TW TW 120"24"103"24"120"24"120"24"120"24"120"24"2/12/2024 Canopy Mounted Signs: 14’ and less = 90% of the length x 24” tall 14’ and more = 70% of the length x 24” tall Flag Mounted Tenant Pucks: (5sf) 9’ to the bottom min. Wall Signs Max 300sf: Between Spandrel. 85% Width x 70% Height 81"24"TB TBTBTBTBTW TWTWTWTW 96"24"120"120"120"24"24"24"2/12/2024 APPROVED BY DATE PAGE 23 Field survey required prior to fabrica on. All electrical is configured to 120V unless otherwise specified. The concepts herein are the property of ISF INC. Permission to reproduce, copy or use the design or proposal can only be obtained through written agreement with ISF INC. Due to screen calibration and printing capabilities, the colors shown are only to be used as a close representation or final product. •DESIGN FABRICATION isfsigns.com 317.251.1219 6468 Rucker Road •INSTALLATION SERVICE Indianapolis, IN 46220 DESIGNED BY: CA REVISED LAST BY: JH 24” T.B.D. SCALE: 3/8”=1’ Face-lit channel letters Faces: 3/16” White acrylic with vinyl overlay (colors TBD) Returns: .040 Aluminum (colors TBD) Trimcap: 1” (colors TBD) Illumination: AVL 6500k White Mounting: Raceway mount to existing canopy (color TBD) TENANT SIGNAGE RACEWAY MOUNTED CHANNEL LETTERS T E N A N T 1 29 WALL SECTION Scale: 1/4”=1’ SIGN TC Scale: 1/2”=1’ Tenants to Fabricate/Install (1) Internally Illuminated Canopy Mounted Sign on Both Front and Rear Elevations (WHERE CANOPIES ARE EXISITNG) Letters: “ TENANT SPACE”: 5” Deep Letter With 1” Recessed Face .080” Aluminum Returns/Faces and Backs Painted: TBD 1/2” Push Thru Acrylic - 1” Clear Acrylic With White Diffuser - 2nd Surface Mounted to 5” x5” Aluminum Raceway - Ptd. To Match Canopy Illuminated with 4500K White LED’s SIGN T Scale: 1/2”=1’ Tenants to Fabricate/Install (1) Non Illuminated Projecting Sign on Both Front and Rear Elevations Letters: “ TENANT SPACE”: 1/4” Flat Cut Acrylic 2” Aluminum Tube Frame - 1/2” Mounting Plate .080” Aluminum Returns/Faces Painted: TBD 1/2” Push Thru Acrylic - 1” Clear Acrylic With White Diffuser - 2nd Surface Mounted to Building Fascia With 1/2” Aluminum Plate - Lag/Shield Fasteners TC TB SIGN TYPE SIGN TYPE 121"192"19 5/8”RETAIL TENANT SIGNAGE REQUIREMENTS - CANOPY TENANT SPACE TENANT SPACETENANT SPACE 5”33” 36" 36”33”24”6 S.F. 6 S.F. Allowed 6 S.F. 96"MAXIMUM WIDTH: 90% of canopy width if 14ft or less 70% of canopy width if more than 14ft. Maximum height 2ft. Maximum area 70sf The Corner Adam Walsh Carmel, IN 11-2-2023 thec_1-2973_v8 Exterior TENANTS WITH CANOPIES 2/12/2024 APPROVED BY DATE PAGE 24 Field survey required prior to fabrica on. All electrical is configured to 120V unless otherwise specified. The concepts herein are the property of ISF INC. Permission to reproduce, copy or use the design or proposal can only be obtained through written agreement with ISF INC. Due to screen calibration and printing capabilities, the colors shown are only to be used as a close representation or final product. •DESIGN FABRICATION isfsigns.com 317.251.1219 6468 Rucker Road •INSTALLATION SERVICE Indianapolis, IN 46220 DESIGNED BY: CA REVISED LAST BY: JH 24” T.B.D. SIDE VIEW 7” EXISTING AWNING SCALE: 3/8”=1’ Face-lit channel letters Faces: 3/16” White acrylic with vinyl overlay (colors TBD) Returns: .040 Aluminum (colors TBD) Trimcap: 1” (colors TBD) Illumination: AVL 6500k White Mounting: Raceway mount to existing canopy (color TBD) TENANT SIGNAGE RACEWAY MOUNTED CHANNEL LETTERS T E N A N T 1 SIGN TW Scale: 1/2”=1’ Tenants to Fabricate/Install (1) Internally Illuminated Wall Sign on Both Front and Rear Elevations (WHERE CANOPIES DO NOT EXIST) Letters: “ TENANT SPACE”: 5” Deep Letter With 1” Recessed Face .080” Aluminum Returns/Faces and Backs Painted: TBD 1/2” Push Thru Acrylic - 1” Clear Acrylic With White Diffuser - 2nd Surface Mounted to 5” x5” Aluminum Raceway - Ptd. To Match Fascia Illuminated with 4500K White LED’s SIGN T Scale: 1/2”=1’ Tenants to Fabricate/Install (1) Non Illuminated Projecting Sign on Both Front and Rear Elevations Letters: “ TENANT SPACE”: 1/4” Flat Cut Acrylic 2” Aluminum Tube Frame - 1/2” Mounting Plate .080” Aluminum Returns/Faces Painted: TBD 1/2” Push Thru Acrylic - 1” Clear Acrylic With White Diffuser - 2nd Surface Mounted to Building Fascia With 1/2” Aluminum Plate - Lag/Shield Fasteners TW TB SIGN TYPE SIGN TYPE 192"19 5/8”RETAIL TENANT SIGNAGE REQUIREMENTS - WALL SIGN TENANT SPACE TENANT SPACE 5”33” 36" 36”33”24”6 S.F. 6 S.F. 70% of Spandrel Height = VARIES 85% of Spandrel Length = VARIES 10% Leeway Allowance for Architectural Elements that hinder visiblity 29 WALL SECTION Scale: 1/4”=1’121"TENANT SPACE 96"The Corner Adam Walsh Carmel, IN 11-2-2023 thec_1-2973_v8 Exterior TENANTS WITHOUT CANOPIES (WHERE CANOPIES ARE EXISITNG) FACADE LETTER RACEWAY SIDE VIEW 2/12/2024 APPROVED BY DATE PAGE 25 Field survey required prior to fabrica on. All electrical is configured to 120V unless otherwise specified. The concepts herein are the property of ISF INC. Permission to reproduce, copy or use the design or proposal can only be obtained through written agreement with ISF INC. Due to screen calibration and printing capabilities, the colors shown are only to be used as a close representation or final product. •DESIGN FABRICATION isfsigns.com 317.251.1219 6468 Rucker Road •INSTALLATION SERVICE Indianapolis, IN 46220 DESIGNED BY: CA REVISED LAST BY: JH 24” T.B.D. SIDE VIEW 7” EXISTING AWNING SCALE: 3/8”=1’ Face-lit channel letters Faces: 3/16” White acrylic with vinyl overlay (colors TBD) Returns: .040 Aluminum (colors TBD) Trimcap: 1” (colors TBD) Illumination: AVL 6500k White Mounting: Raceway mount to existing canopy (color TBD) TENANT SIGNAGE RACEWAY MOUNTED CHANNEL LETTERS T E N A N T 1 The Corner Adam Walsh Carmel, IN 11-2-2023 thec_1-2973_v8 Exterior RETAIL TENANT SIGNAGE REQUIREMENTS: ONE-OFF UNIQUE WHITE STOREFRONT (NORTH ELEVATION BLDG A) PARTIAL NORTH ELEVATION BUILDING A Scale: 1/8”=1’96”SIGN T Scale: 1/2”=1’ Tenants to Fabricate/Install (1) Non Illuminated Projecting Sign on Both Front and Rear Elevations Letters: “ TENANT SPACE”: 1/4” Flat Cut Acrylic 2” Aluminum Tube Frame - 1/2” Mounting Plate .080” Aluminum Returns/Faces Painted: TBD 1/2” Push Thru Acrylic - 1” Clear Acrylic With White Diffuser - 2nd Surface Mounted to Building Fascia With 1/2” Aluminum Plate - Lag/Shield Fasteners TB SIGN TYPE TENANT SPACE TENANT SPACE 5”33” 36" 36”33”24”6 S.F. 6 S.F. 29 WALL SECTION Scale: 1/4”=1’121"TENANT SPACE 96"2/12/2024 APPROVED BY DATE PAGE 21 Field survey required prior to fabrica on. All electrical is configured to 120V unless otherwise specified. The concepts herein are the property of ISF INC. Permission to reproduce, copy or use the design or proposal can only be obtained through written agreement with ISF INC. Due to screen calibration and printing capabilities, the colors shown are only to be used as a close representation or final product. •DESIGN FABRICATION isfsigns.com 317.251.1219 6468 Rucker Road •INSTALLATION SERVICE Indianapolis, IN 46220 DESIGNED BY: CA REVISED LAST BY: JH 24” T.B.D. SIDE VIEW 7” EXISTING AWNING SCALE: 3/8”=1’ Face-lit channel letters Faces: 3/16” White acrylic with vinyl overlay (colors TBD) Returns: .040 Aluminum (colors TBD) Trimcap: 1” (colors TBD) Illumination: AVL 6500k White Mounting: Raceway mount to existing canopy (color TBD) TENANT SIGNAGE RACEWAY MOUNTED CHANNEL LETTERS T E N A N T 1 T E N A N T 1 T E N A N T 2E 116th StWestfield Blvd BUILDING A BUILDING B Legend Blade Sign Count: 4 Wall Sign Count: 1 Retaining Wall Count: 1 Leasing Entrance (Canopy ) Count: 2 A B C D E F G G A1(E) A3(N) A2(NE) A4(NW) B C I ID DE E E E E E E E F F Residential (Primary) - VINYL GRAPHIC Count: 5 Parking Sign Count: 2 Lift Station Wall Count: 1 ***All retail signage to be determined per tenant and permitted at a later date. Building Address I J K TC TW TB K K J J Paseo Wall Parking Sign Parking Garage Entrance Wall Sign Parking Garage Clearance Bars Tenant Canopy Sign Tenant Wall Sign Tenant Blade Sign Count: Count: Count: Count: Count: Count: 2 2 2 7 19 26 CONCEPTUAL, SUBJECT TO CHANGE, FOR ILLUSTRATION PURPOSES ONLY 02/23/21 EXTERIOR SIGNAGE LOCATION The Corner - Carmel, IN L L L Lighting: LED - 4590K Mounting: Projecting Blade Lighting: Internal LED - 4000K Mounting: Flush Mount Wall Sign Lighting: Indirect LED - 4000K Mounting: Stud Mount Lighting: Indirect LED - 4000K Mounting: Stud Mount Lighting: Internal LED - 6500K Mounting: Flush Lighting: Non Illuminated Mounting: Hanging - Aircraft Cables Lighting: Internally Illuminated - LED Mounting: Raceway Mounted to Canopy Lighting: Internally Illuminated - LED Mounting: Raceway Mounted to Fascia Lighting: Non Illuminated Mounting: Projection Lighting: Non Lit Mounting: Stud Mount Lighting: Internal LED - 4000K Mounting: Raceway Canopy Mount Lighting: Internal LED - 6500K Mounting: Projecting Blade K The Corner Adam Walsh Carmel, IN 11-2-2023 thec_1-2973_v8 Exterior TB TB TBTC TC TC TB TB TB TB TC TW TW TC TB TW TB TB TB TB TB TB TB TW TW TW TW TW TC TC TB TB TB TB TB TW TW TW TW TW TB TW TBTBTBTBTB TWTWTWTWTW 2/12/2024 APPROVED BY DATE PAGE 2 Field survey required prior to fabrica on. All electrical is configured to 120V unless otherwise specified. The concepts herein are the property of ISF INC. Permission to reproduce, copy or use the design or proposal can only be obtained through written agreement with ISF INC. Due to screen calibration and printing capabilities, the colors shown are only to be used as a close representation or final product. •DESIGN FABRICATION isfsigns.com 317.251.1219 6468 Rucker Road •INSTALLATION SERVICE Indianapolis, IN 46220 DESIGNED BY: CA REVISED LAST BY: JH BUILDING A • BLADE SIGNS - SIGN TYPE A SIGNS A1(E), A2(NE), A3(N), A4(NW) Scale: 3/8”=1’ Fabricate/Install (1) Internally Illuminated Wall Sign Aluminum Tube Frame / .080” Cladding Painted to Match: MP 23415 EBONY GREEN METALLIC MP 32071 WHITE WONDER Face to Be Recessed 4” with 2x4” Tube Frame Edge of cabinet Recessed 2” GE Tetra Ls Rigid LED Border Tube to run perimeter Mounted Flush to Cabinet Letters “ MUSE”: 4” Deep Letter With 1” Recessed Face Painted Gray/Green to Match: MP 04836 OBSIDIAN 1/2” Push Thru Acrylic - 1” Clear Acrylic With White Diffuser - 2nd Surface Illuminated with 4500K White LED’s Logo Elements: Upper and Lower Logo Elments: 1” Flat Cut Acrylic - Ptd.: MP 10416 TWILIGHT FOREST MP 10535 TONED DOWN TEAL Indirect Illumination - Perimeter Cove LED’s - 4500k White GE Tetra LS 45.2”208.65”7” 32” 4"4" Note: Measurement from Floor Truss Center To Center Stub spread could be adjusted and placed at 10’-6” O.C. If needed. ISF to Field Survey Stub Placements Prior to Fabrication ELECTRICAL SERVICE NOTE: (1) 120v/20amp circuit Req’d for each Sign 15”127 3/4” A SIGN TYPE 16 7/8"16 7/8"Simulated Illuminated View Blades – Muse Building Sign (at top of building) – MuseRetaining Wall Sign – Muse at The CornerParking – Muse at The CornerBrick Wall on trail – Muse at the Corner 16 7/8"Upper and Lower Logo Elments: 1” Flat Cut Acrylic - Ptd. - T.B.D. Indirect Illumination Perimeter Cove LED’s 4500k White 204.65”R: 84 G: 81 B: 74 R: 31 G: 23 B: 35 R: 84 G: 95 B: 96 R: 111 G: 122 B: 122 WHITE TONED DOWN TEAL WHITE WONDERTWILIGHT FORESTEBONY GREEN METALLIC OBSIDIAN MP 10535 MP 32071MP 10416MP 23415 MP 04836 57 3/4"The Corner Adam Walsh Carmel, IN 11-2-2023 thec_1-2973_v8 Exterior 2/12/2024 APPROVED BY DATE PAGE 3 Field survey required prior to fabrica on. All electrical is configured to 120V unless otherwise specified. The concepts herein are the property of ISF INC. Permission to reproduce, copy or use the design or proposal can only be obtained through written agreement with ISF INC. Due to screen calibration and printing capabilities, the colors shown are only to be used as a close representation or final product. •DESIGN FABRICATION isfsigns.com 317.251.1219 6468 Rucker Road •INSTALLATION SERVICE Indianapolis, IN 46220 DESIGNED BY: CA REVISED LAST BY: JH BUILDING A • EAST ELEVATION - A1(E) 25 BUILDING A - ENLARGED EAST ELEVATION 2 Scale: 3/32”=1’ 29 WALL SECTION WALL SECTION DETAIL - OUTRIGGER CONNECTION Scale: 3/32”=1’ Scale: 1/2”=1’ SIGN SUPPORT- OUTRIGGER 18”FASCIA 4” 40" 3” x 3” x 1/4” x 40”L H.S.S. 10” x 18” x 1/2” Steel Plate 10”18” ADDITIONAL BLOCKING DETAILS SHOWN ON PAGE 5 16 7/8"Spandrel: 18” x 372” The Corner Adam Walsh Carmel, IN 11-2-2023 thec_1-2973_v8 Exterior 2/12/2024 APPROVED BY DATE PAGE 4 Field survey required prior to fabrica on. All electrical is configured to 120V unless otherwise specified. The concepts herein are the property of ISF INC. Permission to reproduce, copy or use the design or proposal can only be obtained through written agreement with ISF INC. Due to screen calibration and printing capabilities, the colors shown are only to be used as a close representation or final product. •DESIGN FABRICATION isfsigns.com 317.251.1219 6468 Rucker Road •INSTALLATION SERVICE Indianapolis, IN 46220 DESIGNED BY: CA REVISED LAST BY: JH BUILDING A • EAST ELEVATION - A2(NE), A3(N) Scale: 3/32”=1’Scale: 3/32”=1’Scale: 3/32”=1’ 29 A304 29 A522 8'-6"1'-10 1/4"3'-4"CL 2'-0"3'-0"27 A522 BLDG A L 05 +871'-10 1/16" BLDG A TRUSS BEARING +880'-11 3/16" BLDG A L 02 +839'-10 7/16" BLDG A L 03 +850'-6 5/16" BLDG A L 04 +861'-2 3/16" N BLDG A L 01.2 +818'-6 23/32"T.O.CONC.SLABTOB.O.TRUSS9'-1 1/8"TRUSS1'-6"3/4"SUBFLOORT.O.SUBFLOORTO B.O.TRUSS9'-1 1/8"TRUSS1'-6"3/4"SUBFLOORT.O.SUBFLOORTO B.O.TRUSS9'-1 1/8"TRUSS1'-6"3/4"SUBFLOORT.O.SUBFLOORTO B.O.TRUSS9'-1 1/8"T.O.CONC.SLABTOT.O.SUBFLOOR10'-7 7/8"T.O. SUBFLOORTO T.O.SUBFLOOR10'-7 7/8"T.O. SUBFLOORTO T.O.SUBFLOOR10'-7 7/8"T.O.CONC.SLAB TO T.O.TOPPING10'-9 1/8"T.O.TOPPING TO T.O.TOPPING10'-7 7/8"T.O.TOPPING TO T.O.TOPPING10'-7 7/8"1 1/4" TOPPING1 1/4" TOPPING1 1/4" TOPPINGT.O.CONC SLAB TOT.O.CONC SLAB21'-3 3/4"1'-2" CONC.SLABT.O.CONC SLABTOB.O.CONC SLAB20'-1 3/4"7'-0"JULIETBALCONY,PTD. DOOR ASSCHEDULED PREFABRICATEDWOOD TRUSSES,TYP., RE: STRUCTURAL CONCRETE SLAB OVER VAPOR BARRIER, REF. STRUCTURAL 5/4x6 FIBER CEMENT HEAD TRIM, PTD.,TYP. FIBER CEMENT LAP SIDING (7"EXPOSURE),PTD. CASTSTONEBASE METAL COPING SYSTEM FIBER CEMENT,PTD. 5/4x8FIBER CEMENT TRIM,PTD. 3 FIBER CEMENTTRIM, PTD. FIBER CEMENTLAP SIDING (4"EXPOSURE),PTD. STEELCANOPY, PAINTED 10 A502 27 A522 FIBER CEMENTLAP SIDINGATREAR OF TOWER THINBRICKFINISH WHEREVISIBLE STOREFRONTAS SCHEDULED BRICKVENEER CASTSTONE ACCENT BAND, PROFILE C PREFABRICATEDROOF TRUSSES,TYP., RE: STRUCTURAL SHINGLEROOF BRICKVENEER ROWLOCK BRICKVENEER HERRINGBONE PATTERN (SMOOTH FINISH) INSET BRICK CORBELLING BRICKSOLDIER COURSE CAST STONE ACCENT BAND, PROFILE B CASTSTONE ACCENT BAND, PROFILE D CASTSTONEBASE STEELCANOPY, PTD. 2 1A 1A 4 WINDOWASSCHEDULED FIBER CEMENTLAP SIDING (7"EXPOSURE),PTD. FIBER CEMENT PANEL AND TRIM,PTD. CASTSTONEHEADER, PROFILEE FIBER CEMENTLAP SIDING (4"EXPOSURE),PTD. CASTSTONE ACCENT BAND, PROFILE D 1A 1 12 12 HEELHEIGHT12'-81/2"25 ENLARGED EAST ELEVATION - BUILDING A 29 WALL SECTION AT BALCONY27WALL SECTION AT TOWER A502 A522 A522 "A5522 ""22 16 7/8"Spandrel: 48” x 481” 461 1/2”461 1/2”The Corner Adam Walsh Carmel, IN 11-2-2023 thec_1-2973_v8 Exterior 2/12/2024 APPROVED BY DATE PAGE 5 Field survey required prior to fabrica on. All electrical is configured to 120V unless otherwise specified. The concepts herein are the property of ISF INC. Permission to reproduce, copy or use the design or proposal can only be obtained through written agreement with ISF INC. Due to screen calibration and printing capabilities, the colors shown are only to be used as a close representation or final product. •DESIGN FABRICATION isfsigns.com 317.251.1219 6468 Rucker Road •INSTALLATION SERVICE Indianapolis, IN 46220 DESIGNED BY: CA REVISED LAST BY: JH Scale: 1/32”=1’ Scale: 1/32”=1’ F1 A1(E)A2(NE) A2(NE)A3(N)A4(NW) A3(N) F2198.5”160.375”16 7/8"16 7/8"Spandrel: 18” x 372” Spandrel: 48” x 481” Spandrel: 48” x 481” Spandrel: 48” x 481” Spandrel: 32” x 481” Spandrel: 48” x 481” 461.5”461.5”461.5”429.5”429.5”429.5”429.5”429.5”The Corner Adam Walsh Carmel, IN 11-2-2023 thec_1-2973_v8 Exterior 2/12/2024 APPROVED BY DATE PAGE 6 Field survey required prior to fabrica on. All electrical is configured to 120V unless otherwise specified. The concepts herein are the property of ISF INC. Permission to reproduce, copy or use the design or proposal can only be obtained through written agreement with ISF INC. Due to screen calibration and printing capabilities, the colors shown are only to be used as a close representation or final product. •DESIGN FABRICATION isfsigns.com 317.251.1219 6468 Rucker Road •INSTALLATION SERVICE Indianapolis, IN 46220 DESIGNED BY: CA REVISED LAST BY: JH BUILDING A • NORTHEAST CORNER - BUILDING A • NORTHEAST CORNER - B B SIGN B Scale: 3/4”=1’ Fabricate/Install (1) Internally Illuminated Wall Sign Logo: 5” Deep Can With 1” Recessed Face Exterior / Returns Painted Gray/Green to Match: TBD Inside Face Returns and Face - Painted White 1/2” Push Thru Acrylic - 1/2” Clear Acrylic With White Diffuser - 2nd Surface Illuminated with 4500K White LED’s Push thru Faces Painted: MP 10416 TWILIGHT FOREST MP 10535 TONED DOWN TEAL Letters “ MUSE”: 5” Deep Letter With 1” Recessed Face Painted to Match: MP 04836 OBSIDIAN 1/2” Push Thru Acrylic - 1/2” Clear Acrylic With White Diffuser - 2nd Surface Illuminated with 4500K White LED’s Letters: “AT THE CORNER” - Non Illuminated 1/2” Flat Cut Acrylic - Painted White SIGN BScale: 3/4”=1’Fabricate/Install (1) Internally Illuminated Wall SignAluminum Tube Frame / .080” CladdingPainted Dark Gray to Match SW Paint Code BelowFace to Be Recessed 4” with 2x4” Tube FrameEdge of cabinet Recessed 2” GE Tetra Ls Rigid LED Border Tube to run perimeterMounted Flush to CabinetLetters “ MUSE”: 5” Deep Letter With 1” Recessed FacePainted Gray/Green to Match: TBD1/2” Push Thru Acrylic - 1” Clear Acrylic With White Diffuser - 2nd SurfaceIlluminated with 4500K White LED’sLogo Elements:1” Acrylic Push Thru - Digitally Printed Color on Clear Applied 1st and 2nd SurfaceExact Colors TBD-UV Treated B B SIGN TYPE SIGN TYPE 90.6” 105 3/8"20 3/4”23 1/2”34.5”40 1/4”34.5” 40 1/4” 5" 5"72"72"DAYTIME DAYTIME SIMULATED ILLUMINATED VIEW SIMULATED ILLUMINATED VIEW2 1/4” 2”6 5/8”TONED DOWN TEALTWILIGHT FORESTOBSIDIAN MP 10535MP 10416MP 04836 The Corner Adam Walsh Carmel, IN 11-2-2023 thec_1-2973_v8 Exterior 2/12/2024 APPROVED BY DATE PAGE 7 Field survey required prior to fabrica on. All electrical is configured to 120V unless otherwise specified. The concepts herein are the property of ISF INC. Permission to reproduce, copy or use the design or proposal can only be obtained through written agreement with ISF INC. Due to screen calibration and printing capabilities, the colors shown are only to be used as a close representation or final product. •DESIGN FABRICATION isfsigns.com 317.251.1219 6468 Rucker Road •INSTALLATION SERVICE Indianapolis, IN 46220 DESIGNED BY: CA REVISED LAST BY: JH BUILDING A • NORTHEAST CORNER - B Spandrel: 103” x 172” 44 1/2"27 1/2"15 1/2"15 1/2"The Corner Adam Walsh Carmel, IN 11-2-2023 thec_1-2973_v8 Exterior 2/12/2024 APPROVED BY DATE PAGE 8 Field survey required prior to fabrica on. All electrical is configured to 120V unless otherwise specified. The concepts herein are the property of ISF INC. Permission to reproduce, copy or use the design or proposal can only be obtained through written agreement with ISF INC. Due to screen calibration and printing capabilities, the colors shown are only to be used as a close representation or final product. •DESIGN FABRICATION isfsigns.com 317.251.1219 6468 Rucker Road •INSTALLATION SERVICE Indianapolis, IN 46220 DESIGNED BY: CA REVISED LAST BY: JH SIGN C Fabricate/Install (1) Non Illuminated Wall Sign “MUSE AT THE CORNER” / “ M LOGOS” - 1/2” Flat Cut Acrylic - Ptd. MP 20060 Mounted to Brick Wall with 1/2” Spacers “Buckingham / Kite Plaques” 1” Aluminum Angle Frame / .080” Face (Recessed .9”) - Ptd. MP20060 Logos: 1/4 Flat Cut Acrylic - Ptd. Black Mounted Flush 1” x 1” x 1/4” Standoff Caps - Ptd. Black - Adhered to Face (Decorative) Stud Mounted Flush to Brick Wall C SIGN TYPE 91 1/4” BUILDING A • NORTHEAST CORNER RETAINING WALL - C BRICK - 1Mp20060 Light Taupe metallic (4) 40 Watt - 5650 Lumens LED Flood Light Fixture Kelvin 4000 - 142 Lumens Per Watt Replaces a 150 Watt Metal Halide Knuckle Mount - 120-277 Volt - PLT PremiumSpec 12’ Light Throw @ 10-20’ SKU: PLTS-12300 192”36"56 1/2”105 1/2”22 3/8”6 1/8”50.5”35”561 1/2” 443 3/4” Scale: 1/4”=1’ Scale: 1/4”=1’ 1/4” Flat cut Acrylic 1/4” Flat cut Acrylic 1” x 1/4” Standoff Caps 1” x 1/4” Standoff Caps Digital Print 1” Angle Frame / Recessed Face 1” Angle Frame / Recessed Face15 7/8”30” 35”225”35”15 7/8”443 3/4” 561 5/8” 443.75”50.5”37 7/8"24"The Corner Adam Walsh Carmel, IN 11-2-2023 thec_1-2973_v8 Exterior 2/12/2024 APPROVED BY DATE PAGE 9 Field survey required prior to fabrica on. All electrical is configured to 120V unless otherwise specified. The concepts herein are the property of ISF INC. Permission to reproduce, copy or use the design or proposal can only be obtained through written agreement with ISF INC. Due to screen calibration and printing capabilities, the colors shown are only to be used as a close representation or final product. •DESIGN FABRICATION isfsigns.com 317.251.1219 6468 Rucker Road •INSTALLATION SERVICE Indianapolis, IN 46220 DESIGNED BY: CA REVISED LAST BY: JH BUILDING A • NORTHEAST CORNER RETAINING WALL - C Scale: 3/32’=1’ Scale: 1/4’=1’ Scale: 1/4’=1’ Scale: 1/4’=1’ Scale: 1/4’=1’ Scale: 1/4’=1’ Scale: 1/4’=1’ Scale: 1/4’=1’ 561 5/8” 561 5/8” 373.375” 373.375” 561 5/8” 192” 192” 192” 477.375” 350.5”36”MUSE AT THE CORNER MUSE AT THE CORNER MUSE AT THE CORNER MUSE AT THE CORNER50.5”50.5”50.5”37 7/8"37 7/8"37 7/8"Red Rectangle = “Spandrel”: 50.5” x 561.625” Blue Rectangle = Max. Sign Area: 70%H x 85%W of “Spandrel” 37.875” x 477.375” Red Rectangle = “Spandrel”: 50.5” x 561.625” Blue Rectangle = Max. Sign Area: 70%H x 85%W of “Spandrel” 37.875” x 477.375” Red Rectangle = “Spandrel”: 50.5” x 561.625”Blue Rectangle = Max. Sign Area: 70%H x 85%W of “Spandrel”37.875” x 477.375” 561 5/8” 443.75”50.5”35”The Corner Adam Walsh Carmel, IN 11-2-2023 thec_1-2973_v8 Exterior 2/12/2024 APPROVED BY DATE PAGE 10 Field survey required prior to fabrica on. All electrical is configured to 120V unless otherwise specified. The concepts herein are the property of ISF INC. Permission to reproduce, copy or use the design or proposal can only be obtained through written agreement with ISF INC. Due to screen calibration and printing capabilities, the colors shown are only to be used as a close representation or final product. •DESIGN FABRICATION isfsigns.com 317.251.1219 6468 Rucker Road •INSTALLATION SERVICE Indianapolis, IN 46220 DESIGNED BY: CA REVISED LAST BY: JH BUILDING A • EAST ELEVATION - LEASING CENTER ENTRANCE - D1 29 WALL SECTION Scale: 1/4”=1’ Scale: 3/4”=1’ SIGN D1 Scale: 3/4”=1’ Fabricate/Install (1) Internally Illuminated Canopy Mounted Sign Letters: “ MUSE”: 5” Deep Letter With 1” Recessed Face Painted to Match: MP 04836 OBSIDIAN 1/2” Push Thru Acrylic - 1” Clear Acrylic With White Diffuser - 2nd Surface Mounted to 5” x5” Aluminum Raceway - Ptd. To Match Canopy Illuminated with 4500K White LED’s Letters: “LEASING CENTER” 1/2” Flat Cut Acrylic - Painted White Mounted Flush to Face of Canopy D1 SIGN TYPE 132” 78 5/8”18"121"LEASING CENTERLEASING CENTER 55”4 1/2”25 1/4”Canopy Mounted Signs:14’ and less = 90% of the length x 24” tall14’ and more = 70% of the length x 24” tallFlag Mounted Tenant Pucks: (5sf) 9’ to the bottom min.Wall Signs Max 300sf: Between Spandrel. 85% Width x 70% Height 37’ WHITE WONDEROBSIDIAN MP 32071MP 04836 The Corner Adam Walsh Carmel, IN 11-2-2023 thec_1-2973_v8 Exterior 2/12/2024 APPROVED BY DATE PAGE 11 Field survey required prior to fabrica on. All electrical is configured to 120V unless otherwise specified. The concepts herein are the property of ISF INC. Permission to reproduce, copy or use the design or proposal can only be obtained through written agreement with ISF INC. Due to screen calibration and printing capabilities, the colors shown are only to be used as a close representation or final product. •DESIGN FABRICATION isfsigns.com 317.251.1219 6468 Rucker Road •INSTALLATION SERVICE Indianapolis, IN 46220 DESIGNED BY: CA REVISED LAST BY: JH 25 BUILDING A - ENLARGED EAST ELEVATION 2 Scale: 3/32”=1’ Scale: 1/4”=1’ BUILDING A • EAST ELEVATION - LEASING CENTER ENTRANCE - D1 The Corner Adam Walsh Carmel, IN 11-2-2023 thec_1-2973_v8 Exterior 2/12/2024 APPROVED BY DATE PAGE 12 Field survey required prior to fabrica on. All electrical is configured to 120V unless otherwise specified. The concepts herein are the property of ISF INC. Permission to reproduce, copy or use the design or proposal can only be obtained through written agreement with ISF INC. Due to screen calibration and printing capabilities, the colors shown are only to be used as a close representation or final product. •DESIGN FABRICATION isfsigns.com 317.251.1219 6468 Rucker Road •INSTALLATION SERVICE Indianapolis, IN 46220 DESIGNED BY: CA REVISED LAST BY: JHScale:1/8”=1’ SIGN D2 Scale: 3/4”=1’ Fabricate/Install (1) Internally Illuminated Canopy Mounted Sign Letters “ MUSE”: 5” Deep Letter With 1” Recessed Face Painted Gray/Green to Match: MP 04836 OBSIDIAN 1/2” Push Thru Acrylic - 1” Clear Acrylic With White Diffuser - 2nd Surface Mounted to 5” x5” Aluminum Raceway - Ptd. To Match Canopy Illuminated with 4500K White LED’s D2 SIGN TYPE 90” 61”13 5/8”BUILDING A • WEST ELEVATION - REAR LEASING CENTER ENTRANCE - D2 LEASING CENTER 42 7/8” LEASING CENTER20 3/4”WHITE WONDEROBSIDIAN MP 32071MP 04836 The Corner Adam Walsh Carmel, IN 11-2-2023 thec_1-2973_v8 Exterior 2/12/2024 APPROVED BY DATE PAGE 13 Field survey required prior to fabrica on. All electrical is configured to 120V unless otherwise specified. The concepts herein are the property of ISF INC. Permission to reproduce, copy or use the design or proposal can only be obtained through written agreement with ISF INC. Due to screen calibration and printing capabilities, the colors shown are only to be used as a close representation or final product. •DESIGN FABRICATION isfsigns.com 317.251.1219 6468 Rucker Road •INSTALLATION SERVICE Indianapolis, IN 46220 DESIGNED BY: CA REVISED LAST BY: JH SIGN E Scale: 3”=1’ Fabricate/Install (8) Custom Cut Vinyl Graphics Opaque Gray Or digitally Printed Color - TBD Applied to 1st Surface Door Glass SIGN TYPE BUILDING A • WEST ELEVATION - RESIDENTIAL ENTRANCE - E E Scale: 1/4”=1’12”12” A A6"6” The Corner Adam Walsh Carmel, IN 11-2-2023 thec_1-2973_v8 Exterior 2/12/2024 APPROVED BY DATE PAGE 14 Field survey required prior to fabrica on. All electrical is configured to 120V unless otherwise specified. The concepts herein are the property of ISF INC. Permission to reproduce, copy or use the design or proposal can only be obtained through written agreement with ISF INC. Due to screen calibration and printing capabilities, the colors shown are only to be used as a close representation or final product. •DESIGN FABRICATION isfsigns.com 317.251.1219 6468 Rucker Road •INSTALLATION SERVICE Indianapolis, IN 46220 DESIGNED BY: CA REVISED LAST BY: JH SIGN TYPE F LEFT ELEVATION SCALE: 3/4”=1’ RIGHT ELEVATION SCALE: 3/4”=1’ WALL FACING ELEVATION SCALE: 3/4”=1’ SCALE: 1 1/2”=1’F1-F2 Fabricate and install (2) exterior 2 sided face lit blade sign Main Cabinet - .080” aluminum cladding, .040” returns, & 2” retainer painted MP 413420 Brushed Aluminum Border: 1/2” Clear Acrylic Push-thrus w/ second surface diffuser vinyl Face: .090” Aluminum Painted PMS 072C Blue match w/ routed text and border “P”, Arrows”, PUBLIC PARKING: 1/2” push through clear acrylic with second surface diffuser vinyl Bottom Arm - .080” aluminum cladding, routed for 1/2” arrow clear acrylic push-thru w/ second surface diffuser - Front elevation painted PMS 1245C Yellow, side and back elevations painted PMS 1245C Yellow, PMS 491C Red Spacers - .080” aluminum cladding painted MP 413420 Brushed Aluminum Mounting: T.B.D. Option 1: Match Plate via 15” x 12” x 1/2” Steel mounting plates painted MP 413420 brushed aluminum flush to existing attachments by others with 3/4” x 2.5” Stainless Steel Bolts Option 2: Thru Bolt with 3/4” All-Thread Thru 3/4” Wood Blocking Option 3: Concrete Expansion Anchors - 1/2” x 6” Illumination: AVL 6500 White LEDs - Include Photocells ALL MATERIALS MUST BE NON- CORROSIVE TO AVOID LEAKY LINES AND DETERIORATION 32” CENTER TO CENTERCL 12"15" 15"12"12"9"CL CL CL CL PLATE DETAIL 7/8” DIA. 2” Power Hole (Bottom plate only) 15”12”60 1/4”24”72 1/2”120v Power RUN THRU BOTTOM LEG OF SIGN 44”NOTE: SITE SURVEY REQ’D PRIOR TO FABRICATION TO CONFIRM 44” BRACKET SPREAD WILL FIT. ELECTRICAL SERVICE NOTE: (1) 120v/20amp circuit Req’d for each Sign56"The Corner Adam Walsh Carmel, IN 11-2-2023 thec_1-2973_v8 Exterior 2/12/2024 APPROVED BY DATE PAGE 15 Field survey required prior to fabrica on. All electrical is configured to 120V unless otherwise specified. The concepts herein are the property of ISF INC. Permission to reproduce, copy or use the design or proposal can only be obtained through written agreement with ISF INC. Due to screen calibration and printing capabilities, the colors shown are only to be used as a close representation or final product. •DESIGN FABRICATION isfsigns.com 317.251.1219 6468 Rucker Road •INSTALLATION SERVICE Indianapolis, IN 46220 DESIGNED BY: CA REVISED LAST BY: JH SIGN TYPE SIGN TYPE G G LIFT STATION ELEVATION LIFT STATION ELEVATION LIFT STATION ELEVATION Scale: 1/4”=1’ Scale: 1/4”=1’ Scale: 1/4”=1’ SIGN G Scale: 3/8”=1’ SIGN G - Option 2 Scale: 3/4”=1’ Fabricate/Install (1) Non Illuminated Wall Sign “MUSE” - 1/2” Flat Cut Acrylic - Ptd. TBD Mounted to Brick Wall with 1/2” Spacers “AT THE CORNER” 1/4” Flat Cut Acrylic - Ptd. TBD Mounted Flush to Brisk Wall41 7/8”123 1/8”26 3/8”406 5/8” 406 5/8” 406 5/8”7 1/4”AUXILIARY BLDG. • LIFT STATION WALL - G 60 3/8”60 3/8”192”36"105 1/2”22 3/8”6 1/8”MUSE AT THE CORNER 345 5/8”42 1/4”37 3/8”37 3/8”15 3/4”345 5/8” 239 1/8” (4) 40 Watt - 5650 Lumens LED Flood Light Fixture Kelvin 4000 - 142 Lumens Per Watt Replaces a 150 Watt Metal Halide Knuckle Mount - 120-277 Volt - PLT PremiumSpec 12’ Light Throw @ 10-20’ SKU: PLTS-12300 MUSE AT THE CORNER 12”45 1/4” Scale: 3/4”=1’ 1/4” Flat cut Acrylic 1/4” Flat cut Acrylic 1/4” Flat cut Acrylic 3/4” x 1/4” Standoff Caps Digital Print 1” Angle Frame / Recessed Face Fabricate/Install (1) Non Illuminated Wall Sign “MUSE AT THE CORNER” / “ M LOGOS” - 1/2” Flat Cut Acrylic - Ptd. MP 20060 Mounted to Brick Wall with 1/2” Spacers “Buckingham / Kite Plaque” 1” Aluminum Angle Frame / .080” Face (Recessed .9”) - Ptd. MP20060 Logos: 1/4 Flat Cut Acrylic - (Smaller Elements and Letters to be 1/8”) - Ptd. Black Mounted Flush 3/4” x 3/4” x 1/4” Standoff Caps - Ptd. Black - Adhered to Face (Decorative) Stud Mounted Flush to Brick Wall BRICK - 1Mp20060 Light Taupe metallic (3) 40 Watt - 5650 Lumens LED Flood Light Fixture Kelvin 4000 - 142 Lumens Per Watt Replaces a 150 Watt Metal Halide Knuckle Mount - 120-277 Volt - PLT PremiumSpec 12’ Light Throw @ 10-20’ SKU: PLTS-12300 10 3/8”The Corner Adam Walsh Carmel, IN 11-2-2023 thec_1-2973_v8 Exterior 2/12/2024 APPROVED BY DATE PAGE 16 Field survey required prior to fabrica on. All electrical is configured to 120V unless otherwise specified. The concepts herein are the property of ISF INC. Permission to reproduce, copy or use the design or proposal can only be obtained through written agreement with ISF INC. Due to screen calibration and printing capabilities, the colors shown are only to be used as a close representation or final product. •DESIGN FABRICATION isfsigns.com 317.251.1219 6468 Rucker Road •INSTALLATION SERVICE Indianapolis, IN 46220 DESIGNED BY: CA REVISED LAST BY: JH SIGN TYPE I1-I2 Fabricate and install (2) exterior non-lit wall signs Option 1 (Non Lit): Letters: 1/2” Flat Cut Acrylic - Painted White - Stud Mounted Flush to Fascia “P” Pucks: 1/2” flat Cut Acrylic Painted White - Digitally Printed Color - UV Laminate - Stud mounted Flush to Fascia CO PUBLIC PARKING GARAGE33 5/8”20 1/2”11 1/8”477 5/8” Scale: 1/4”=1’ Scale: 1/2”=1’ 158.5” NOTE: FIELD VERIFY FASCIA DIMENSIONS PRIOR TO FABRICATION CO PUBLIC PARKING GARAGE 2” x 2” Dimensional Trim I 193 3/4”13 1/2”8 5/8”15”28 5/8”The Corner Adam Walsh Carmel, IN 11-2-2023 thec_1-2973_v8 Exterior 2/12/2024 APPROVED BY DATE PAGE 17 Field survey required prior to fabrica on. All electrical is configured to 120V unless otherwise specified. The concepts herein are the property of ISF INC. Permission to reproduce, copy or use the design or proposal can only be obtained through written agreement with ISF INC. Due to screen calibration and printing capabilities, the colors shown are only to be used as a close representation or final product. •DESIGN FABRICATION isfsigns.com 317.251.1219 6468 Rucker Road •INSTALLATION SERVICE Indianapolis, IN 46220 DESIGNED BY: CA REVISED LAST BY: JH BUILDING A • PARTIAL EAST ELEVATION BUILDING A • PARTIAL NORTH ELEVATION 213.75”175.5”Scale: 3/32”=1’Scale: 3/32”=1’ I1 I2 CO PUBLIC PARKING GARAGE CO PUBLIC PARKING GARAGE The Corner Adam Walsh Carmel, IN 11-2-2023 thec_1-2973_v8 Exterior 2/12/2024 APPROVED BY DATE PAGE 18 Field survey required prior to fabrica on. All electrical is configured to 120V unless otherwise specified. The concepts herein are the property of ISF INC. Permission to reproduce, copy or use the design or proposal can only be obtained through written agreement with ISF INC. Due to screen calibration and printing capabilities, the colors shown are only to be used as a close representation or final product. •DESIGN FABRICATION isfsigns.com 317.251.1219 6468 Rucker Road •INSTALLATION SERVICE Indianapolis, IN 46220 DESIGNED BY: CA REVISED LAST BY: JH PUBLIC PARKING13”SIGN TYPE J1-J2 210” PARKING GARAGE ENTRANCE WALL SIGN J J 5” Scale: 3/4”=1’ The Corner Adam Walsh Carmel, IN 11-2-2023 thec_1-2973_v8 Exterior 2/12/2024 ST. K Fabricate and install QTY (2) Garage Clearance Bars 6” Polyethylene tube Painted Yellow with Custom cut Black / White Reflective vinyl graphics Eye-bolt/aircraft cable installation 6 1/4”80” CONTENT SHOWN AS PLACE HOLDER TO BE CONFIRMED - FIELD SURVEY PRIOR TO PRODUCTION K APPROVED BY DATE PAGE 19 Field survey required prior to fabrica on. All electrical is configured to 120V unless otherwise specified. The concepts herein are the property of ISF INC. Permission to reproduce, copy or use the design or proposal can only be obtained through written agreement with ISF INC. Due to screen calibration and printing capabilities, the colors shown are only to be used as a close representation or final product. •DESIGN FABRICATION isfsigns.com 317.251.1219 6468 Rucker Road •INSTALLATION SERVICE Indianapolis, IN 46220 DESIGNED BY: CA REVISED LAST BY: JH The Corner Adam Walsh Carmel, IN 11-2-2023 thec_1-2973_v8 Exterior 2/12/2024 APPROVED BY DATE PAGE 20 Field survey required prior to fabrica on. All electrical is configured to 120V unless otherwise specified. The concepts herein are the property of ISF INC. Permission to reproduce, copy or use the design or proposal can only be obtained through written agreement with ISF INC. Due to screen calibration and printing capabilities, the colors shown are only to be used as a close representation or final product. •DESIGN FABRICATION isfsigns.com 317.251.1219 6468 Rucker Road •INSTALLATION SERVICE Indianapolis, IN 46220 DESIGNED BY: CA REVISED LAST BY: JH GA RA GE O PENNESS GARAGE L 0 1 +819'-10" GARAGE L 02 +830 '-4" GARAGE L 0 3 +840 '-10" GARAGE L 0 4 +851'-4" GARAGE L 05 +861'-10" CAST CONCRETE C OLUM N,TYP. REF.STRUCTURAL CAST CONCRETE BUM PER W ALL,TYP. REF.STRUCTURAL STEEL SUPPORT FOR SOLAR PANELSNORTHELEVATION:2,451OPEN AREA /5,0 40 SF PERIM ETER AREA =49%OPENNESS ART INSTALLATION 5'-0"WIDE BY 3'-6"DEEP PREM AUFACTURED M ETAL CANOPY, BOTTOM OF C ANOPY TO BE 7'-2" ABOVE CONCRETE DEC K 3 STONE PATTERN CONCRETE FORM LINER,TYP. 4 26 NO RTH ELEVA TIO N -GA RA G E PUBLIC PARKING Scale: 1/16” =1’ Scale: 1/16” =1’ 13 EA ST ELEV A TIO N -GA RA G E PUBLIC PARKING PARKING GARAGE ENTRANCE WALL SIGN - ELEVATIONS J K& NOTE: ART INSTALLATION TO BE INSTALLED 15” ABOVE BOTTOM OF 2nd FLOOR DECK TO ALLOW 13”h SIGN TO BE MOUNTED FLUSH. The Corner Adam Walsh Carmel, IN 11-2-2023 thec_1-2973_v8 Exterior 2/12/2024