Loading...
HomeMy WebLinkAboutA110 - UNIT B AND C - DEMOLITION AND FIRST FLOOR ARCHITECTURAL PLANARCHITECTURAL PLAN NOTES (ALL NOTES MAY NOT BE INDICATED ON THIS SHEET) INDICATES WALL TYPE. REFER TO DRAWING A1.00 FOR WALL THICKNESS, HEIGHT AND COMPOSITION. ARCHITECTURAL PLAN GENERAL NOTES A. ALL CMU WALLS THAT DO NOT LAY OUT IN FULL OR HALF LENGTHS SHOULD BE BALANCED SO AS NOT TO HAVE ANY PIECES LESS THAN 4" IN SIZE EXPOSED TO VIEW. B. WHERE DISSIMILAR FLOOR MATERIALS MEET, THEY SHALL DO SO UNDER THE CENTERLINE OF THE DOOR, UNLESS NOTED OTHERWISE. C. THERE SHALL BE PERIMETER INSULATION CONTINUOUS AROUND THE ENTIRE PERIMETER OF THE BUILDING EXTENDING 2'-0" MINIMUM BELOW GRADE. D. THE BASE FLOOR ELEVATION INDICATED FOR THE PROJECT IS 100'-0". REFER TO SITE PLAN FOR CORRELATION TO USGS DATUM. E. ALL INTERIOR MASONRY WALLS THAT RUN TO UNDERSIDE OF DECK ABOVE SHALL HAVE A 2" JOINT (U.N.O.) AT THE DECK TO BE FILLED WITH FIRE STOPPING AT RATED WALLS PER PROJECT MANUAL., AND MINERAL WOOL AT THE NON-RATED WALLS, TO ALLOW FOR DEFLECTION. F. FOR TYPICAL COMMON JOINT DETAILS AND CONSTRUCTION MOVEMENT JOINT DETAILS REFER TO DETAILS ON SHEET XX. G. ALL DIMENSIONS ON FLOOR PLANS ARE TO FINISH FACE OF CMU, CONCRETE, BRICK OR FINISH FACE OF GWB AT METAL STUD WALLS, UNLESS NOTED OTHERWISE. EXCEPTION: EXTERIOR METAL STUD WALLS ARE TO FACE OF METAL STUDS. H. HINGE SIDE DOOR JAMB AT WALLS WILL TYPICALLY BE LOCATED 4" MINIMUM FROM ADJACENT WALL UNLESS NOTED OTHERWISE. I. ALL EXPOSED CONCRETE MASONRY UNITS (CMU) CORNERS ARE TO BE BULLNOSE, EXCEPT AT BULKHEADS, WINDOW AND DOOR HEADS. J. SEE REFLECTED CEILING PLANS FOR BULKHEAD LOCATIONS AND DETAIL REFERENCES. K. REFER TO ROOM FINISH SCHEDULE OR PLAN AND EQUIPMENT PLANS FOR LOCATION AND EXTENT OF FINISH FLOOR MATERIALS. L. PROVIDE WOOD BLOCKING AS REQUIRED. WITHIN METAL STUD WALLS FOR WALL MOUNTED ITEMS. M. REFER TO MASTER/CODE PLANS FOR CODE INFORMATION AND FIRE RATED WALL LOCATIONS. N. PROVIDE SPRAY FOAM INSULATION AND THERMAL BARRIER CONTINUOUS AT INTERSECTION OF EXTERIOR WALLS AND DECK. VERIFICATION NOTE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CLEARANCES AND ALL EXISTING FIELD CONDITIONS BEFORE STARTING CONSTRUCTION. COMMENCEMENT OF WORK CONSTITUTES ACCEPTANCE OF CONDITIONS. SHOULD DIFFERENT CONDITIONS BE ENCOUNTERED, CONTACT THE ARCHITECT BEFORE PROCEEDING WITH WORK. X W### V A3.013 DRAWING CLASSROOM / LAB C125 CORRIDOR C101F CULINARY ARTS C124 10 S U DOOR 11 UNIT BUNIT AUNIT B CORRIDOR C131 CLOSET C124A DRY GOODS C124B WALK-IN C124C VESTIBULE C101G 23 9 TYP. C101H C101G C124BC124C C124ASF7V.1 W 11 10 1 A5.02 ___________ 3 A5.02 ___________ 10'-0"21'-11"16'-0"W11 W12 W11 W117'-2"W82S W86S W10 1 A5.03 ___________ 12 10'-6"8'-9 3/4"14'-8"13'-6"6 5/8"6"6"6'-11"1'-0"5'-1"3'-4"2'-1" 2'-3 3/4" 5'-4"1'-2" 5'-0 3/8" TD SD TD SD 19 A1.06 3 A1.06 7 4 MH W13 25 25 SIM. CORRIDOR C101F UNIT BUNIT AUNIT B DOOR 11 PAINTING & PRINTMAKING LAB C124 CORRIDOR C131 DRAWING CLASSROOM / LAB C125 VESTIBULE C101G AD27 AD5 AD7 AD4 AD6 AD13 AD8 AD8 AD8 AD8 AD13 AD4 AD6 AD28 AD44 AD29 AD29 AD32 AD30 AD43 AD42 AD30 AD9 AD7 AD47 AD34 AD26 AD32 AT EXISTING JOINT DEMOLITION PLAN NOTES (ALL NOTES MAY NOT BE INDICATED ON THIS SHEET) ARCHITECTURAL DEMOLITION GENERAL NOTES X A. DEMOLITION IS TO FOLLOW ESTABLISHED CONSTRUCTION SEQUENCE. CONTRACTOR IS TO VERIFY THEIR WORK IN THE FIELD WITH THE DEMOLITION DRAWINGS, NEW CONSTRUCTION DRAWINGS, AND THE EXISTING IN-FIELD CONDITIONS. REPORT DISCREPANCIES TO THE ARCHITECT. B. "FLOORING" DENOTES FLOOR COVERING MATERIALS INCLUDING BACKINGS, ADHESIVES, BASES, DOWN TO BUT EXCLUSIVE OF FLOOR SLABS AND STRUCTURAL MATERIALS, UNLESS NOTED OTHERWISE. C. "CEILING" DENOTES CEILING MATERIALS INCLUDING SUSPENSION SYSTEMS ADHESIVE RESIDUES, MOLDINGS, UP TO BUT EXCLUSIVE OF STRUCTURAL MATERIALS. D. WALLS TO BE REMOVED SHALL BE REMOVED TO A POINT 2" (MIN.) BELOW THE EXISTING FLOOR SLAB (UNLESS SETTING ON SLAB). PATCH WITH NEW CONCRETE TO BE FLUSH WITH THE EXISTING FLOOR SLAB. E. WHEN OPENINGS ARE CUT INTO AN EXISTING WALL, THE OPENING SHALL BE A MINIMUM OF 1'-4" LONGER THAN THE FINISHED OPENING REQUIRED TO ALLOW FOR 8" (MIN) OF NEW CMU TOOTHED-IN AT EDGES. F. AFTER THE DEMOLITION OF MATERIALS, THE RESULTING EXPOSED SURFACE SHALL BE SMOOTH AND FLUSH WITH EXISTING CONDITIONS. G. MECHANICAL AND ELECTRICAL ITEMS THAT ARE CAPPED AND ABANDONED SHALL BE LOCATED BEHIND FINAL FINISH SYSTEMS. H. COORDINATE THIS WORK WITH DEMOLITION WORK ON SITE, STRUCTURAL, PLUMBING, MECHANICAL, AND ELECTRICAL. I. PROVIDE INTERIOR AND EXTERIOR SHORING, BRACING, OR SUPPORT TO PREVENT MOVEMENT OR SETTLEMENT OF EXISTING STRUCTURES. J. CONTRACTOR TO FIELD VERIFY PORTIONS OR SECTIONS OF EXISTING WALLS TO BE FILLED IN AND SALVAGE NECESSARY MATERIAL. K. MATERIALS OF DEMOLITION SHALL BE DISPOSED OF OFF- SITE UNLESS OTHERWISE DIRECTED BY OWNER. L. OWNER TO REMOVE EXISTING FURNITURE AND MISCELLANEOUS ITEMS NOT SHOWN AND NOT TO BE DEMOLISHED. CONTRACTOR TO NOTIFY OWNER IN ADVANCE WHEN ITEMS NEED TO BE REMOVED. CONTRACTOR IS RESPONSIBLE FOR OTHER ITEMS TO BE REMOVED. M. ITEMS TO BE PATCHED. REMOVE ALL LOOSE OR DAMAGED MATERIAL. REFINISH TO LIKE NEW CONDITION, OR IF CONDITION WARRANTS REPLACE IN ENTIRETY. N. THE OWNER SHALL RESERVE RIGHT TO CLAIM ANY MATERIALS THAT ARE BEING DEMOLISHED PRIOR TO THE CONTRACTOR DISPOSING OF THEM OFF SITE. O. "TURNED OVER TO THE OWNER" DENOTES: 1) TAG AND IDENTIFY ITEMS: 2) STORE IN AN ORDERLY FASHION IN A LOCATION DESIGNATED BY THE OWNER. P. ITEMS MADE OBSOLETE TO ACCOMODATE NEW CONSTRUCTION OR RENOVATION SHALL BE REMOVED. Q. ITEMS TO BE REMOVED SHALL BE REMOVED IN THEIR ENTIRETY. R. AFTER REMOVAL OF ITEMS, THE EXISTING WALL SURFACES (IF EXPOSED) SHALL BE REPAIRED/PATCHED AS REQUIRED TO RECEIVE NEW FINISHES. VERIFICATION NOTE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CLEARANCES AND ALL EXISTING FIELD CONDITIONS BEFORE STARTING CONSTRUCTION. COMMENCEMENT OF WORK CONSTITUTES ACCEPTANCE OF CONDITIONS. SHOULD DIFFERENT CONDITIONS BE ENCOUNTERED, CONTACT THE ARCHITECT BEFORE PROCEEDING WITH WORK. DEMOLITION PLAN NOTES (CONTINUED) (ALL NOTES MAY NOT BE INDICATED ON THIS SHEET) X CLASSROOM C139 TV CLASSROOM C141 STUDIO A C143 COMPUTER CLASSROOM C145 PODCAST C149A STUDIO B C141A STUDIO C132 TV-CPU LAB C150 PODCAST C133 COMPUTER LAB C136A ELECTRICAL ROOM C148 OFFICE C141B ENGINEERING C142A TV CONTROL C144 SECURE CLOSET C145A STORAGE C136 PASSAGE C138A STUDIO C138B STUDIO C138C STUDIO C138D STUDIO C138E PASSAGE C134 STUDIO C135 STUDIO C137 STUDIO C138 OFFICE C101H OFFICE C147A YEARBOOK CLASSROOM / LAB C149 AD5 AD8 AD17 AD18 AD18 AD5 AD16 AD5 AD36 GRAPHICS C142 AD3 AD17 AD35 AD16 AD3 AD5 AD45 AD36 AD5 AD15 AD13 AD36 AD13 EXISTING RAMP TO REMAIN. AD45 AD26 AD3 AD13 AD13 CLASSROOM C139 TV CLASSROOM C141 STUDIO A C143 COMPUTER CLASSROOM C145 PODCAST C149A STUDIO B C141A STUDIO B C142 STUDIO C132 TV-CPU LAB C150 PODCAST C133 COMPUTER LAB C136A ELECTRICAL ROOM C148 OFFICE C141B ENGINEERING C142A TV CONTROL C144 SECURE CLOSET C145A STORAGE C136 PASSAGE C138A STUDIO C138B STUDIO C138C STUDIO C138D STUDIO C138E PASSAGE C134 STUDIO C135 STUDIO C137 STUDIO C138 OFFICE C101H OFFICE C147A YEARBOOK CLASSROOM / LAB C149 1 5 5 5 5 EQUIPMENT ROOM C144A 1 15 13 C1448'-8"C142 C133 13 W13 1 16 15 5 15 16 16 C100C136 C142A4 1/4" COPYRIGHT 2023 BY FANNING/HOWEY ASSOCIATES, INC. KEY PLAN UNIT B WWW.FHAI.COM ARCHITECT UNIT C 9/13/2023 6:02:13 PM\\data1\citrixprofiles$\droan\upm_profile\Documents\2021_ARCH_221165.01_droanR3Y2M.rvtPROJECT NUMBER: 221165.01 CARMEL HIGH SCHOOL POLYTECHNIC ADDITION AND RENOVATION CARMEL CLAY SCHOOLS 520 EAST MAIN STREET CARMEL, IN 46032 UNIT B AND C -DEMOLITION AND FIRST FLOOR ARCHITECTURAL PLAN A1.03 PROJECT ISSUE DATE: 09/20/2023 REGULATORY REVIEW DRAWN BY: DSR 317-848-0966 350 E. NEW YORK ST. SUITE 300, INDIANAPOLIS, IN 46204 SCALE: 1/8" = 1'-0" UNIT B - FIRST FLOOR ARCHITECTURAL PLAN SCALE: 1/8" = 1'-0" UNIT B - FIRST FLOOR DEMOLITION PLAN NO.DESCRIPTION 1 INFILL OPENING TO MATCH EXISTING WALL CONSTRUCTION. FINISH FLUSH WITH ADJACENT SURFACES TO SHOW NO EVIDENCE OF CONSTRUCTION. TOOTH-IN MASONRY WITH EXISTING. 2 CONCRETE FILLED, METAL PAIN STAIRS. SEE A10.02 FOR ADDITIONAL INFORMATION. 3 WIRE MESH PARTITION SYSTEM. INCORPORATE MORTISE LOCK CYLINDER AND CORE IN GATE. SEE DOOR SCHEDULE AND SPECIFICAITONS. 4 PRE-FINISHED STEEL LOCKERS. SEE EQUIPMENT PLANS FOR ADDITIONAL INFORMATION. 5 PROVIDE NEW ACOUSTICAL WALL TREATMENT. SEE FINISH PLANS, INTERIOR ELEVATIONS AND SPECIFICATIONS FOR ADDITIONAL INFORMATION. 6 24" WIDE, FIXED ALUMINUM ACCESS LADDER. SEE DETAIL 8/A10.02. 7 MEMBRANE ROOF SYSTEM. SEE ROOF PLAN FOR ADDITIONAL INFORMATION. 8 METAL PIPE GUARDRAIL SYSTEM. SEE A10.02. 9 KITCHEN EQUIPMENT. SEE FOOD SERVICE DRAWINGS FOR ADDITIONAL INFORMATION. 10 INFILL PORTION OF CONCRETE SLAB. FINISH FLUSH WITH EXISTING. SEE PLUMBING FOR ADDITIONAL INFORMATION. 11 INDICATES 12' x 12' AREA FOR STUDENT-BUILT HOUSE BUILD. (FOR REFERENCE ONLY) 12 INDICATES 12' x 32' AREA FOR STUDENT-BUILT TINY HOMES. (FOR REFERENCE ONLY) 13 ACOUSTICALLY SEAL ALL WALL PENETRATIONS ABOVE CEILING, BOTH SIDES OF WALL. INFILL MASONRY OPENINGS WITH CMU SOAP / MORTAR AS REQUIRED. 14 EXISTING STEEL BASE AND WOOD TOP WORKBENCHES. COORDINATE FINAL LOCATION WITH OWNER UPON COMPLETION OF OTHER FINISHES. 15 2-LAYERS OF 5/8" TYPE "X" GYP. BOARD OVER EXISTING METAL FURRING. EXTEND GYP. BOARD AND SEAL TOP EDGE TO CONCRETE DECK ABOVE. 16 PROVIDE WOOD FLOOR FRAMING TO MATCH EXISTING DEPTH AND REPLACE TILE ACCESS FLOOR. SEE DETAIL 2/A1.07. 17 INFILL PORTION OF CONCRETE SLAB. FINISH FLUSH WITH EXISTING. SEE STRUCTURAL FOR ADDITIONAL INFORMATION. 18 CONCRETE FILLED STEEL PIPE BOLLARD WITH COVER. SEE DETAIL 7/A1.07 FOR ADDITIONAL INFORMATION. 19 1 1/2" PRE-COMPRESSED BUILDING EXPANSION JOINT WITH CONTINUOUS SEALANT. 20 PLASTIC LAMINATE CASEWORK. SEE EQUIPMENT PLANS FOR ADDITIONAL INFORMATION. 21 13'W x 12'H MASONRY OPENING. SEE STRUCTURAL. 22 GUARDRAIL GATE - SEE 5-7/A10.01. 23 INFILL OPENING TO MATCH EXISTING WALL CONSTRUCTION. GROUND FACE CMU TO MATCH EXISTING, FULL HEIGHT. FINISH FLUSH WITH ADJACENT SURFACES TO SHOW NO EVIDENCE OF CONSTRUCTION. TOOTH-IN MASONRY WITH EXISTING. 24 PAINT BOOTH EXHAUST, UP THROUGH ROOF. SEE EQUIPMENT PLANS AND SCHEDULE FOR ADDITIONAL INFORMATION. COORDINATE FINAL LOCATION, DIMENSIONS AND OPENINGS BETWEEN ALL TRADES AND EQUIPMENT MANUFACTURER. 25 SEMI-RECESSED FIRE EXTINGUISHER CABINET. SEE 3/A1.07 AND SPECIFICATIONS FOR ADDITIONAL INFORMATION. NO.DESCRIPTION AD35 REMOVE ACOUSTICAL WALL PANELS IN THEIR ENTIRETY. EXISTING CMU WALL TO REMAIN. PREPARE CMU TO RECEIVE NEW FINISHES. AD36 REMOVE WALL CARPET IN IT'S ENTIRETY. REMOVE ADHESIVES BACK TO EXISTING CMU SUBSTRATE. GRINDING MAY BE REQUIRED TO REMOVE ADHESIVE AND CREATE A SMOOTH SUBSTRATE SUITABLE FOR NEW MATERIAL. AD37 SALVAGE EXISTING STEEL BASE AND WOOD TOP WORK BENCHES. RELOCATE AS REQUIRED FOR INSTALLATION OF NEW WORK. COORDINATE NEW LOCATION WITH OWNER. AD38 EXISTING DISPLAY BOARD / CASE / PROJECTION SCREEN TO REMAIN. PROTECT FROM DAMAGE DURING CONSTRUCTION. REMOVE AND RE-INSTALL AS REQUIRED FOR NEW WORK. AD39 DISCONNECT AND REMOVE EXISTING VEHICLE LIFT IN IT'S ENTIRETY. AD40 REMOVE EXISTING WALL MOUNTED RED TOOL CABINETS. SALVAGE AND PROVIDE TO OWNER. AD41 REMOVE VINYL WALL COVERING AND TACK SURFACE / CORK, BACK TO CMU SUBSTRATE. REMOVE ADHESIVES BACK TO EXISTING CMU SUBSTRATE. GRINDING MAY BE REQUIRED TO REMOVE ADHESIVE AND CREATE A SMOOTH SUBSTRATE SUITABLE FOR NEW MATERIAL. AD42 REMOVE EXISTING PRE-CAST BUILDING IN IT'S ENTIRETY, INCLUDING ANY BELOW GRADE FOUNDATIONS. SEE CIVIL FOR ADDITIONAL INFORMATION. AD43 REMOVE EXISTING VCT FLOORING, WALL BASE AND TRANSITIONS. REMOVE ADHESIVES DOWN TO EXISTING SLAB. PREPARE SURFACE TO RECEIVE NEW FINISHES. AD44 REMOVE GYP. BOARD IN IT'S ENTIRETY BACK TO METAL STUD FRAMING. METAL STUD FRAMING TO REMAIN. AD45 REMOVE EXISTING ACCESS FLOORING AND ALL SUPPORTS / ACCESSORIES DOWN TO EXISTING SLAB. PREPARE SURFACE TO RECEIVE NEW FINISHES. AD46 EXISTING CONCRETE SLAB TO REMAIN. REMOVE EXISTING FLOOR SEALER AND WALL BASE IN IT'S ENTIRETY. PREPARE SURFACES TO RECEIVE NEW FINISHES. AD47 REMOVE BULLNOSE GROUND FACE CMU AT CORNERS. PREPARE ADJACENT SURFACES FOR NEW WORK. NO.DESCRIPTION AD1 REMOVE BRICK VENEER / CMU SCREEN WALL IN ITS ENTIRETY, INCLUDING ALL STONE CAPS AND ALL BELOW-GRADE FOUNDATIONS. SEE CIVIL FOR ADDITIONAL INFORMATION. AD2 REMOVE MASONRY WALL IN IT'S ENTIRETY. PREPARE ADJACENT SURFACES FOR NEW CONSTRUCTION. AD3 REMOVE DOOR, FRAME AND ALL ASSOCIATED HARDWARE IN IT'S ENTIRETY. PREPARE OPENING AND ADJACENT SURFACES FOR NEW WORK. AD4 REMOVE PLUMBING FIXTURE IN IT'S ENTIRETY. SEE PLUMBING FOR ADDITIONAL INFORMATION. AD5 REMOVE EXISTING CARPET, WALL BASE AND TRANSITIONS. REMOVE ADHESIVES DOWN TO EXISTING SLAB. PREPARE SURFACE TO RECEIVE NEW FINISHES. AD6 REMOVE ALL WALL MOUNTED ACCESSORIES IN THEIR ENTIRETY, INCLUDING MIRRORS, SOAP DISPENSERS, PAPER TOWEL DISPENSERS, FEMININE NAPKIN DISPOSALS, TOILET PAPER DISPENSERS AND FIRE EXTINGUISHER CABINETS. AD7 REMOVE EXISTING LOCKERS AND BASE IN THEIR ENTIRETY. AD8 REMOVE EXISTING CASEWORK, SHELVING AND / OR MILLWORK ITEMS, ALONG WITH ALL RELATED ACCESSORIES. PATCH AND REPAIR ADJACENT WALL AND FLOOR SURFACES AND PREPARE TO ACCEPT NEW FINISHES. AD9 REMOVE WALL MOUNTED DISPLAY BOARD / CASE / PROJECTION SCREEN IN IT'S ENTIRETY. AD10 REMOVE EXISTING CONCRETE PAVING IN IT'S ENTIRETY TO EXISTING STONE BASE. PREPARE FOR NEW CONSTRUCTION. SEE CIVIL / STRUCTURAL FOR ADDITIONAL INFORMATION. AD11 REMOVE EXISTING CONCRETE CURB IN IT'S ENTIRETY. PROTECT ADJACENT WALL FROM DAMAGE DURING CONSTRUCTION. SEE CIVIL. AD12 REMOVE EXISTING GUARDRAIL IN IT'S ENTIRETY. PREPARE TOP OF EXISTING, RETAINING WALL FOR NEW CONSTRUCTION. SEE STRUCTURAL AND CIVIL FOR ADDITIONAL INFORMATION. AD13 REMOVE DOOR, FRAME AND ALL ASSOCIATED HARDWARE IN IT'S ENTIRETY. PREPARE OPENING FOR NEW DOOR / FRAME. AD14 REMOVE CHAIN LINK FENCE / GATE IN IT'S ENTIRETY. AD15 EXISTING CASEWORK TO REMAIN. PROTECT FROM DAMAGE DURING CONSTRUCTION. AD16 REMOVE HOLLOW METAL FRAME / WINDOW UNIT IN ITS ENTIRETY. PREPARE WALL FOR NEW WORK. AD17 REMOVE ACOUSTICAL WALL PANELS AND WOOD DIFFUSER PANELS IN THEIR ENTIRETY. REMOVE GYP. BOARD BACK TO METAL STUD WALL FRAMING / FURRING. METAL STUD FRAMING / FURRING TO REMAIN. PREPARE TO RECEIVE NEW FINISHES. AD18 REMOVE EXISTING WOOD TRIM IN IT'S ENTIRETY. EXISTING WINDOW / FRAME TO REMAIN. PREPARE TO RECEIVE NEW FINISHES. AD19 REMOVE EXISTING 2X WOOD FRAMED AND PLYWOOD FLOOR STORAGE MEZZANINE AND RAILING IN IT'S ENTIRETY. AD20 REMOVE EXISTING STEEL FRAMED AND CONCRETE / METAL DECK WITH STEEL BEAM STORAGE MEZZANINE IN IT'S ENTIRETY, INCLUDING METAL GRATING STAIRS AND PIPE RAILINGS. AD21 REMOVE WOOD FRAMED STAIRS AND RAILING IN THEIR ENTIRETY. AD22 REMOVE PORTION OF EXISTING MASONRY / BRICK VENEER WALL. PREPARE FOR NEW OPENING. PROVIDE ALL NECESSARY SHORING / SUPPORT FOR REMAINING WALL DURING CONSTRUCTION. SEE STRUCUTRAL FOR ADDITIONAL INFORMATION. AD23 REMOVE WOOD FRAMED WINDOW UNIT IN IT'S ENTIRETY. PREPARE OPENING FOR NEW WORK. AD24 REMOVE METAL ACCESS LADDER IN IT'S ENTIRETY. AD25 REMOVE WELDING CURTAIN, HOOD AND ALL ASSOCIATED ACCESSORIES. SEE MECHANICAL FOR ADDITIONAL INFORMATION. AD26 REMOVE PORTION OF EXISTING MASONRY WALL. PREPARE FOR NEW OPENING. PROVIDE ALL NECESSARY SHORING / SUPPORT FOR REMAINING WALL DURING CONSTRUCTION. SEE STRUCUTRAL FOR ADDITIONAL INFORMATION. AD27 REMOVE ALUMINUM STOREFRONT DOOR / GLAZING SYSTEM IN IT'S ENTIRETY, INCLUDING ALL ASSOCIATED SUPPORTS / BRACING. PREPARE ADJACENT SURFACES FOR NEW FINISHES. AD28 REMOVE ALUMINUM FRAMED GLAZING SYSTEM IN IT'S ENTIRETY. PREPARE ADJACENT SURFACES FOR NEW FINISHES. AD29 REMOVE VINYL WALL COVERING AND GYP. BOARD BACK TO CMU SUBSTRATE. PREPARE CMU FOR NEW FINISHES. AD30 SAWCUT AND REMOVE PORTION OF EXISTING SLAB FOR NEW PLUMBING PIPING. SEE PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION. AD31 REMOVE PAINT BOOTH IN IT'S ENTIRETY, INCLUDING ALL ASSOCIATED DUCTWORK AND EQUIPMENT. SEE MECHANICAL FOR ADDITIONAL INFORMATION. AD32 REMOVE PORTION OF TERAZZO FLOORING DOWN TO CONCRETE SLAB BELOW TO ACOMMODATE NEW CONSTRUCTION. PROVIDE SELF-LEVELING FLOOR PATCH AS REQUIRED AND PREPARE SLAB FOR NEW FINISHES. AD33 EXISTING LOCKERS TO REMAIN. PROTECT FROM DAMAGE DURING CONSTRUCTION. AD34 SAWCUT AND REMOVE PORTION OF EXISTING SLAB FOR NEW FOOTING. SEE STRUCTURAL FOR ADDITIONAL INFORMATION. SCALE: 1/8" = 1'-0" UNIT C - FIRST FLOOR DEMOLITION PLAN SCALE: 1/8" = 1'-0" UNIT C - FIRST FLOOR ARCHITECTURAL PLAN PLANNORTHREV. NO.DESCRIPTION DATE