HomeMy WebLinkAboutA110 - UNIT B AND C - DEMOLITION AND FIRST FLOOR ARCHITECTURAL PLANARCHITECTURAL PLAN NOTES
(ALL NOTES MAY NOT BE INDICATED ON THIS SHEET)
INDICATES WALL TYPE. REFER TO
DRAWING A1.00 FOR WALL THICKNESS,
HEIGHT AND COMPOSITION.
ARCHITECTURAL PLAN GENERAL NOTES
A. ALL CMU WALLS THAT DO NOT LAY OUT IN FULL OR
HALF LENGTHS SHOULD BE BALANCED SO AS NOT
TO HAVE ANY PIECES LESS THAN 4" IN SIZE EXPOSED
TO VIEW.
B. WHERE DISSIMILAR FLOOR MATERIALS MEET, THEY
SHALL DO SO UNDER THE CENTERLINE OF THE DOOR,
UNLESS NOTED OTHERWISE.
C. THERE SHALL BE PERIMETER INSULATION CONTINUOUS
AROUND THE ENTIRE PERIMETER OF THE BUILDING
EXTENDING 2'-0" MINIMUM BELOW GRADE.
D. THE BASE FLOOR ELEVATION INDICATED FOR THE
PROJECT IS 100'-0". REFER TO SITE PLAN FOR
CORRELATION TO USGS DATUM.
E. ALL INTERIOR MASONRY WALLS THAT RUN TO
UNDERSIDE OF DECK ABOVE SHALL HAVE A 2" JOINT
(U.N.O.) AT THE DECK TO BE FILLED WITH FIRE
STOPPING AT RATED WALLS PER PROJECT MANUAL.,
AND MINERAL WOOL AT THE NON-RATED WALLS, TO
ALLOW FOR DEFLECTION.
F. FOR TYPICAL COMMON JOINT DETAILS AND
CONSTRUCTION MOVEMENT JOINT DETAILS REFER TO
DETAILS ON SHEET XX.
G. ALL DIMENSIONS ON FLOOR PLANS ARE TO FINISH
FACE OF CMU, CONCRETE, BRICK OR FINISH FACE OF
GWB AT METAL STUD WALLS, UNLESS NOTED
OTHERWISE. EXCEPTION: EXTERIOR METAL STUD
WALLS ARE TO FACE OF METAL STUDS.
H. HINGE SIDE DOOR JAMB AT WALLS WILL TYPICALLY BE
LOCATED 4" MINIMUM FROM ADJACENT WALL UNLESS
NOTED OTHERWISE.
I. ALL EXPOSED CONCRETE MASONRY UNITS (CMU)
CORNERS ARE TO BE BULLNOSE, EXCEPT AT
BULKHEADS, WINDOW AND DOOR HEADS.
J. SEE REFLECTED CEILING PLANS FOR BULKHEAD
LOCATIONS AND DETAIL REFERENCES.
K. REFER TO ROOM FINISH SCHEDULE OR PLAN AND
EQUIPMENT PLANS FOR LOCATION AND EXTENT OF
FINISH FLOOR MATERIALS.
L. PROVIDE WOOD BLOCKING AS REQUIRED. WITHIN
METAL STUD WALLS FOR WALL MOUNTED ITEMS.
M. REFER TO MASTER/CODE PLANS FOR CODE
INFORMATION AND FIRE RATED WALL LOCATIONS.
N. PROVIDE SPRAY FOAM INSULATION AND THERMAL
BARRIER CONTINUOUS AT INTERSECTION OF EXTERIOR
WALLS AND DECK.
VERIFICATION NOTE
CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND
CLEARANCES AND ALL EXISTING FIELD CONDITIONS
BEFORE STARTING CONSTRUCTION. COMMENCEMENT
OF WORK CONSTITUTES ACCEPTANCE OF CONDITIONS.
SHOULD DIFFERENT CONDITIONS BE ENCOUNTERED,
CONTACT THE ARCHITECT BEFORE PROCEEDING WITH
WORK.
X
W###
V
A3.013
DRAWING
CLASSROOM / LAB
C125
CORRIDOR
C101F
CULINARY ARTS
C124
10
S
U
DOOR 11 UNIT BUNIT AUNIT B
CORRIDOR
C131
CLOSET
C124A
DRY GOODS
C124B
WALK-IN
C124C
VESTIBULE
C101G
23
9 TYP.
C101H
C101G
C124BC124C
C124ASF7V.1
W
11
10
1
A5.02
___________
3
A5.02
___________
10'-0"21'-11"16'-0"W11
W12
W11
W117'-2"W82S
W86S
W10
1
A5.03
___________
12
10'-6"8'-9 3/4"14'-8"13'-6"6 5/8"6"6"6'-11"1'-0"5'-1"3'-4"2'-1"
2'-3 3/4"
5'-4"1'-2"
5'-0 3/8"
TD
SD
TD
SD
19
A1.06
3
A1.06
7
4
MH
W13
25
25
SIM.
CORRIDOR
C101F UNIT BUNIT AUNIT B
DOOR 11
PAINTING &
PRINTMAKING LAB
C124
CORRIDOR
C131
DRAWING
CLASSROOM / LAB
C125
VESTIBULE
C101G
AD27
AD5
AD7
AD4
AD6
AD13
AD8
AD8
AD8
AD8
AD13
AD4
AD6
AD28
AD44
AD29
AD29
AD32
AD30
AD43
AD42
AD30
AD9
AD7
AD47
AD34
AD26
AD32 AT EXISTING
JOINT
DEMOLITION PLAN NOTES
(ALL NOTES MAY NOT BE INDICATED ON THIS SHEET)
ARCHITECTURAL DEMOLITION GENERAL NOTES
X
A. DEMOLITION IS TO FOLLOW ESTABLISHED CONSTRUCTION
SEQUENCE. CONTRACTOR IS TO VERIFY THEIR WORK IN
THE FIELD WITH THE DEMOLITION DRAWINGS, NEW
CONSTRUCTION DRAWINGS, AND THE EXISTING IN-FIELD
CONDITIONS. REPORT DISCREPANCIES TO THE ARCHITECT.
B. "FLOORING" DENOTES FLOOR COVERING MATERIALS
INCLUDING BACKINGS, ADHESIVES, BASES, DOWN TO BUT
EXCLUSIVE OF FLOOR SLABS AND STRUCTURAL
MATERIALS, UNLESS NOTED OTHERWISE.
C. "CEILING" DENOTES CEILING MATERIALS INCLUDING
SUSPENSION SYSTEMS ADHESIVE RESIDUES, MOLDINGS,
UP TO BUT EXCLUSIVE OF STRUCTURAL MATERIALS.
D. WALLS TO BE REMOVED SHALL BE REMOVED TO A POINT 2"
(MIN.) BELOW THE EXISTING FLOOR SLAB (UNLESS SETTING
ON SLAB). PATCH WITH NEW CONCRETE TO BE FLUSH WITH
THE EXISTING FLOOR SLAB.
E. WHEN OPENINGS ARE CUT INTO AN EXISTING WALL, THE
OPENING SHALL BE A MINIMUM OF 1'-4" LONGER THAN THE
FINISHED OPENING REQUIRED TO ALLOW FOR 8" (MIN) OF
NEW CMU TOOTHED-IN AT EDGES.
F. AFTER THE DEMOLITION OF MATERIALS, THE RESULTING
EXPOSED SURFACE SHALL BE SMOOTH AND FLUSH WITH
EXISTING CONDITIONS.
G. MECHANICAL AND ELECTRICAL ITEMS THAT ARE CAPPED
AND ABANDONED SHALL BE LOCATED BEHIND FINAL FINISH
SYSTEMS.
H. COORDINATE THIS WORK WITH DEMOLITION WORK ON
SITE, STRUCTURAL, PLUMBING, MECHANICAL, AND
ELECTRICAL.
I. PROVIDE INTERIOR AND EXTERIOR SHORING, BRACING, OR
SUPPORT TO PREVENT MOVEMENT OR SETTLEMENT OF
EXISTING STRUCTURES.
J. CONTRACTOR TO FIELD VERIFY PORTIONS OR SECTIONS
OF EXISTING WALLS TO BE FILLED IN AND SALVAGE
NECESSARY MATERIAL.
K. MATERIALS OF DEMOLITION SHALL BE DISPOSED OF OFF-
SITE UNLESS OTHERWISE DIRECTED BY OWNER.
L. OWNER TO REMOVE EXISTING FURNITURE AND
MISCELLANEOUS ITEMS NOT SHOWN AND NOT TO BE
DEMOLISHED. CONTRACTOR TO NOTIFY OWNER IN
ADVANCE WHEN ITEMS NEED TO BE REMOVED.
CONTRACTOR IS RESPONSIBLE FOR OTHER ITEMS TO BE
REMOVED.
M. ITEMS TO BE PATCHED. REMOVE ALL LOOSE OR DAMAGED
MATERIAL. REFINISH TO LIKE NEW CONDITION, OR IF
CONDITION WARRANTS REPLACE IN ENTIRETY.
N. THE OWNER SHALL RESERVE RIGHT TO CLAIM ANY
MATERIALS THAT ARE BEING DEMOLISHED PRIOR TO THE
CONTRACTOR DISPOSING OF THEM OFF SITE.
O. "TURNED OVER TO THE OWNER" DENOTES: 1) TAG AND
IDENTIFY ITEMS: 2) STORE IN AN ORDERLY FASHION IN A
LOCATION DESIGNATED BY THE OWNER.
P. ITEMS MADE OBSOLETE TO ACCOMODATE NEW
CONSTRUCTION OR RENOVATION SHALL BE REMOVED.
Q. ITEMS TO BE REMOVED SHALL BE REMOVED IN THEIR
ENTIRETY.
R. AFTER REMOVAL OF ITEMS, THE EXISTING WALL SURFACES
(IF EXPOSED) SHALL BE REPAIRED/PATCHED AS REQUIRED
TO RECEIVE NEW FINISHES.
VERIFICATION NOTE
CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND
CLEARANCES AND ALL EXISTING FIELD CONDITIONS
BEFORE STARTING CONSTRUCTION. COMMENCEMENT
OF WORK CONSTITUTES ACCEPTANCE OF CONDITIONS.
SHOULD DIFFERENT CONDITIONS BE ENCOUNTERED,
CONTACT THE ARCHITECT BEFORE PROCEEDING WITH
WORK.
DEMOLITION PLAN NOTES (CONTINUED)
(ALL NOTES MAY NOT BE INDICATED ON THIS SHEET)
X
CLASSROOM
C139
TV CLASSROOM
C141
STUDIO A
C143
COMPUTER
CLASSROOM
C145
PODCAST
C149A
STUDIO B
C141A
STUDIO
C132
TV-CPU LAB
C150
PODCAST
C133
COMPUTER LAB
C136A
ELECTRICAL
ROOM
C148
OFFICE
C141B
ENGINEERING
C142A
TV CONTROL
C144
SECURE CLOSET
C145A
STORAGE
C136
PASSAGE
C138A
STUDIO
C138B
STUDIO
C138C
STUDIO
C138D
STUDIO
C138E
PASSAGE
C134
STUDIO
C135
STUDIO
C137
STUDIO
C138
OFFICE
C101H
OFFICE
C147A
YEARBOOK
CLASSROOM / LAB
C149
AD5
AD8
AD17
AD18
AD18
AD5
AD16
AD5
AD36
GRAPHICS
C142
AD3
AD17
AD35
AD16
AD3
AD5
AD45
AD36
AD5 AD15
AD13
AD36
AD13
EXISTING RAMP
TO REMAIN.
AD45
AD26
AD3
AD13
AD13
CLASSROOM
C139
TV CLASSROOM
C141
STUDIO A
C143
COMPUTER
CLASSROOM
C145
PODCAST
C149A
STUDIO B
C141A
STUDIO B
C142
STUDIO
C132
TV-CPU LAB
C150
PODCAST
C133
COMPUTER LAB
C136A
ELECTRICAL
ROOM
C148
OFFICE
C141B
ENGINEERING
C142A
TV CONTROL
C144
SECURE CLOSET
C145A
STORAGE
C136
PASSAGE
C138A
STUDIO
C138B
STUDIO
C138C
STUDIO
C138D
STUDIO
C138E
PASSAGE
C134
STUDIO
C135
STUDIO
C137
STUDIO
C138
OFFICE
C101H
OFFICE
C147A
YEARBOOK
CLASSROOM / LAB
C149
1
5
5
5 5
EQUIPMENT ROOM
C144A
1
15
13 C1448'-8"C142
C133
13
W13
1
16
15
5
15
16
16
C100C136 C142A4 1/4"
COPYRIGHT 2023 BY FANNING/HOWEY ASSOCIATES, INC.
KEY PLAN
UNIT B
WWW.FHAI.COM
ARCHITECT
UNIT C
9/13/2023 6:02:13 PM\\data1\citrixprofiles$\droan\upm_profile\Documents\2021_ARCH_221165.01_droanR3Y2M.rvtPROJECT NUMBER: 221165.01
CARMEL HIGH
SCHOOL
POLYTECHNIC
ADDITION AND
RENOVATION
CARMEL CLAY SCHOOLS
520 EAST MAIN STREET
CARMEL, IN 46032
UNIT B AND C -DEMOLITION AND
FIRST FLOOR ARCHITECTURAL
PLAN
A1.03
PROJECT ISSUE DATE: 09/20/2023
REGULATORY REVIEW
DRAWN BY: DSR
317-848-0966
350 E. NEW YORK ST. SUITE 300, INDIANAPOLIS, IN 46204
SCALE: 1/8" = 1'-0"
UNIT B - FIRST FLOOR ARCHITECTURAL PLAN
SCALE: 1/8" = 1'-0"
UNIT B - FIRST FLOOR DEMOLITION PLAN
NO.DESCRIPTION
1 INFILL OPENING TO MATCH EXISTING WALL CONSTRUCTION.
FINISH FLUSH WITH ADJACENT SURFACES TO SHOW NO
EVIDENCE OF CONSTRUCTION. TOOTH-IN MASONRY WITH
EXISTING.
2 CONCRETE FILLED, METAL PAIN STAIRS. SEE A10.02 FOR
ADDITIONAL INFORMATION.
3 WIRE MESH PARTITION SYSTEM. INCORPORATE MORTISE
LOCK CYLINDER AND CORE IN GATE. SEE DOOR SCHEDULE
AND SPECIFICAITONS.
4 PRE-FINISHED STEEL LOCKERS. SEE EQUIPMENT PLANS
FOR ADDITIONAL INFORMATION.
5 PROVIDE NEW ACOUSTICAL WALL TREATMENT. SEE FINISH
PLANS, INTERIOR ELEVATIONS AND SPECIFICATIONS FOR
ADDITIONAL INFORMATION.
6 24" WIDE, FIXED ALUMINUM ACCESS LADDER. SEE DETAIL
8/A10.02.
7 MEMBRANE ROOF SYSTEM. SEE ROOF PLAN FOR
ADDITIONAL INFORMATION.
8 METAL PIPE GUARDRAIL SYSTEM. SEE A10.02.
9 KITCHEN EQUIPMENT. SEE FOOD SERVICE DRAWINGS FOR
ADDITIONAL INFORMATION.
10 INFILL PORTION OF CONCRETE SLAB. FINISH FLUSH WITH
EXISTING. SEE PLUMBING FOR ADDITIONAL INFORMATION.
11 INDICATES 12' x 12' AREA FOR STUDENT-BUILT HOUSE BUILD.
(FOR REFERENCE ONLY)
12 INDICATES 12' x 32' AREA FOR STUDENT-BUILT TINY HOMES.
(FOR REFERENCE ONLY)
13 ACOUSTICALLY SEAL ALL WALL PENETRATIONS ABOVE
CEILING, BOTH SIDES OF WALL. INFILL MASONRY OPENINGS
WITH CMU SOAP / MORTAR AS REQUIRED.
14 EXISTING STEEL BASE AND WOOD TOP WORKBENCHES.
COORDINATE FINAL LOCATION WITH OWNER UPON
COMPLETION OF OTHER FINISHES.
15 2-LAYERS OF 5/8" TYPE "X" GYP. BOARD OVER EXISTING
METAL FURRING. EXTEND GYP. BOARD AND SEAL TOP EDGE
TO CONCRETE DECK ABOVE.
16 PROVIDE WOOD FLOOR FRAMING TO MATCH EXISTING
DEPTH AND REPLACE TILE ACCESS FLOOR. SEE DETAIL
2/A1.07.
17 INFILL PORTION OF CONCRETE SLAB. FINISH FLUSH WITH
EXISTING. SEE STRUCTURAL FOR ADDITIONAL
INFORMATION.
18 CONCRETE FILLED STEEL PIPE BOLLARD WITH COVER. SEE
DETAIL 7/A1.07 FOR ADDITIONAL INFORMATION.
19 1 1/2" PRE-COMPRESSED BUILDING EXPANSION JOINT WITH
CONTINUOUS SEALANT.
20 PLASTIC LAMINATE CASEWORK. SEE EQUIPMENT PLANS
FOR ADDITIONAL INFORMATION.
21 13'W x 12'H MASONRY OPENING. SEE STRUCTURAL.
22 GUARDRAIL GATE - SEE 5-7/A10.01.
23 INFILL OPENING TO MATCH EXISTING WALL CONSTRUCTION.
GROUND FACE CMU TO MATCH EXISTING, FULL HEIGHT.
FINISH FLUSH WITH ADJACENT SURFACES TO SHOW NO
EVIDENCE OF CONSTRUCTION. TOOTH-IN MASONRY WITH
EXISTING.
24 PAINT BOOTH EXHAUST, UP THROUGH ROOF. SEE
EQUIPMENT PLANS AND SCHEDULE FOR ADDITIONAL
INFORMATION. COORDINATE FINAL LOCATION, DIMENSIONS
AND OPENINGS BETWEEN ALL TRADES AND EQUIPMENT
MANUFACTURER.
25 SEMI-RECESSED FIRE EXTINGUISHER CABINET. SEE 3/A1.07
AND SPECIFICATIONS FOR ADDITIONAL INFORMATION.
NO.DESCRIPTION
AD35 REMOVE ACOUSTICAL WALL PANELS IN THEIR ENTIRETY.
EXISTING CMU WALL TO REMAIN. PREPARE CMU TO
RECEIVE NEW FINISHES.
AD36 REMOVE WALL CARPET IN IT'S ENTIRETY. REMOVE
ADHESIVES BACK TO EXISTING CMU SUBSTRATE. GRINDING
MAY BE REQUIRED TO REMOVE ADHESIVE AND CREATE A
SMOOTH SUBSTRATE SUITABLE FOR NEW MATERIAL.
AD37 SALVAGE EXISTING STEEL BASE AND WOOD TOP WORK
BENCHES. RELOCATE AS REQUIRED FOR INSTALLATION OF
NEW WORK. COORDINATE NEW LOCATION WITH OWNER.
AD38 EXISTING DISPLAY BOARD / CASE / PROJECTION SCREEN TO
REMAIN. PROTECT FROM DAMAGE DURING CONSTRUCTION.
REMOVE AND RE-INSTALL AS REQUIRED FOR NEW WORK.
AD39 DISCONNECT AND REMOVE EXISTING VEHICLE LIFT IN IT'S
ENTIRETY.
AD40 REMOVE EXISTING WALL MOUNTED RED TOOL CABINETS.
SALVAGE AND PROVIDE TO OWNER.
AD41 REMOVE VINYL WALL COVERING AND TACK SURFACE /
CORK, BACK TO CMU SUBSTRATE. REMOVE ADHESIVES
BACK TO EXISTING CMU SUBSTRATE. GRINDING MAY BE
REQUIRED TO REMOVE ADHESIVE AND CREATE A SMOOTH
SUBSTRATE SUITABLE FOR NEW MATERIAL.
AD42 REMOVE EXISTING PRE-CAST BUILDING IN IT'S ENTIRETY,
INCLUDING ANY BELOW GRADE FOUNDATIONS. SEE CIVIL
FOR ADDITIONAL INFORMATION.
AD43 REMOVE EXISTING VCT FLOORING, WALL BASE AND
TRANSITIONS. REMOVE ADHESIVES DOWN TO EXISTING
SLAB. PREPARE SURFACE TO RECEIVE NEW FINISHES.
AD44 REMOVE GYP. BOARD IN IT'S ENTIRETY BACK TO METAL
STUD FRAMING. METAL STUD FRAMING TO REMAIN.
AD45 REMOVE EXISTING ACCESS FLOORING AND ALL SUPPORTS /
ACCESSORIES DOWN TO EXISTING SLAB. PREPARE
SURFACE TO RECEIVE NEW FINISHES.
AD46 EXISTING CONCRETE SLAB TO REMAIN. REMOVE EXISTING
FLOOR SEALER AND WALL BASE IN IT'S ENTIRETY. PREPARE
SURFACES TO RECEIVE NEW FINISHES.
AD47 REMOVE BULLNOSE GROUND FACE CMU AT CORNERS.
PREPARE ADJACENT SURFACES FOR NEW WORK.
NO.DESCRIPTION
AD1 REMOVE BRICK VENEER / CMU SCREEN WALL IN ITS
ENTIRETY, INCLUDING ALL STONE CAPS AND ALL
BELOW-GRADE FOUNDATIONS. SEE CIVIL FOR ADDITIONAL
INFORMATION.
AD2 REMOVE MASONRY WALL IN IT'S ENTIRETY. PREPARE
ADJACENT SURFACES FOR NEW CONSTRUCTION.
AD3 REMOVE DOOR, FRAME AND ALL ASSOCIATED HARDWARE
IN IT'S ENTIRETY. PREPARE OPENING AND ADJACENT
SURFACES FOR NEW WORK.
AD4 REMOVE PLUMBING FIXTURE IN IT'S ENTIRETY. SEE
PLUMBING FOR ADDITIONAL INFORMATION.
AD5 REMOVE EXISTING CARPET, WALL BASE AND TRANSITIONS.
REMOVE ADHESIVES DOWN TO EXISTING SLAB. PREPARE
SURFACE TO RECEIVE NEW FINISHES.
AD6 REMOVE ALL WALL MOUNTED ACCESSORIES IN THEIR
ENTIRETY, INCLUDING MIRRORS, SOAP DISPENSERS, PAPER
TOWEL DISPENSERS, FEMININE NAPKIN DISPOSALS, TOILET
PAPER DISPENSERS AND FIRE EXTINGUISHER CABINETS.
AD7 REMOVE EXISTING LOCKERS AND BASE IN THEIR ENTIRETY.
AD8 REMOVE EXISTING CASEWORK, SHELVING AND / OR
MILLWORK ITEMS, ALONG WITH ALL RELATED
ACCESSORIES. PATCH AND REPAIR ADJACENT WALL AND
FLOOR SURFACES AND PREPARE TO ACCEPT NEW
FINISHES.
AD9 REMOVE WALL MOUNTED DISPLAY BOARD / CASE /
PROJECTION SCREEN IN IT'S ENTIRETY.
AD10 REMOVE EXISTING CONCRETE PAVING IN IT'S ENTIRETY TO
EXISTING STONE BASE. PREPARE FOR NEW
CONSTRUCTION. SEE CIVIL / STRUCTURAL FOR ADDITIONAL
INFORMATION.
AD11 REMOVE EXISTING CONCRETE CURB IN IT'S ENTIRETY.
PROTECT ADJACENT WALL FROM DAMAGE DURING
CONSTRUCTION. SEE CIVIL.
AD12 REMOVE EXISTING GUARDRAIL IN IT'S ENTIRETY. PREPARE
TOP OF EXISTING, RETAINING WALL FOR NEW
CONSTRUCTION. SEE STRUCTURAL AND CIVIL FOR
ADDITIONAL INFORMATION.
AD13 REMOVE DOOR, FRAME AND ALL ASSOCIATED HARDWARE
IN IT'S ENTIRETY. PREPARE OPENING FOR NEW DOOR /
FRAME.
AD14 REMOVE CHAIN LINK FENCE / GATE IN IT'S ENTIRETY.
AD15 EXISTING CASEWORK TO REMAIN. PROTECT FROM DAMAGE
DURING CONSTRUCTION.
AD16 REMOVE HOLLOW METAL FRAME / WINDOW UNIT IN ITS
ENTIRETY. PREPARE WALL FOR NEW WORK.
AD17 REMOVE ACOUSTICAL WALL PANELS AND WOOD DIFFUSER
PANELS IN THEIR ENTIRETY. REMOVE GYP. BOARD BACK TO
METAL STUD WALL FRAMING / FURRING. METAL STUD
FRAMING / FURRING TO REMAIN. PREPARE TO RECEIVE
NEW FINISHES.
AD18 REMOVE EXISTING WOOD TRIM IN IT'S ENTIRETY. EXISTING
WINDOW / FRAME TO REMAIN. PREPARE TO RECEIVE NEW
FINISHES.
AD19 REMOVE EXISTING 2X WOOD FRAMED AND PLYWOOD
FLOOR STORAGE MEZZANINE AND RAILING IN IT'S
ENTIRETY.
AD20 REMOVE EXISTING STEEL FRAMED AND CONCRETE / METAL
DECK WITH STEEL BEAM STORAGE MEZZANINE IN IT'S
ENTIRETY, INCLUDING METAL GRATING STAIRS AND PIPE
RAILINGS.
AD21 REMOVE WOOD FRAMED STAIRS AND RAILING IN THEIR
ENTIRETY.
AD22 REMOVE PORTION OF EXISTING MASONRY / BRICK VENEER
WALL. PREPARE FOR NEW OPENING. PROVIDE ALL
NECESSARY SHORING / SUPPORT FOR REMAINING WALL
DURING CONSTRUCTION. SEE STRUCUTRAL FOR
ADDITIONAL INFORMATION.
AD23 REMOVE WOOD FRAMED WINDOW UNIT IN IT'S ENTIRETY.
PREPARE OPENING FOR NEW WORK.
AD24 REMOVE METAL ACCESS LADDER IN IT'S ENTIRETY.
AD25 REMOVE WELDING CURTAIN, HOOD AND ALL ASSOCIATED
ACCESSORIES. SEE MECHANICAL FOR ADDITIONAL
INFORMATION.
AD26 REMOVE PORTION OF EXISTING MASONRY WALL. PREPARE
FOR NEW OPENING. PROVIDE ALL NECESSARY SHORING /
SUPPORT FOR REMAINING WALL DURING CONSTRUCTION.
SEE STRUCUTRAL FOR ADDITIONAL INFORMATION.
AD27 REMOVE ALUMINUM STOREFRONT DOOR / GLAZING SYSTEM
IN IT'S ENTIRETY, INCLUDING ALL ASSOCIATED SUPPORTS /
BRACING. PREPARE ADJACENT SURFACES FOR NEW
FINISHES.
AD28 REMOVE ALUMINUM FRAMED GLAZING SYSTEM IN IT'S
ENTIRETY. PREPARE ADJACENT SURFACES FOR NEW
FINISHES.
AD29 REMOVE VINYL WALL COVERING AND GYP. BOARD BACK TO
CMU SUBSTRATE. PREPARE CMU FOR NEW FINISHES.
AD30 SAWCUT AND REMOVE PORTION OF EXISTING SLAB FOR
NEW PLUMBING PIPING. SEE PLUMBING DRAWINGS FOR
ADDITIONAL INFORMATION.
AD31 REMOVE PAINT BOOTH IN IT'S ENTIRETY, INCLUDING ALL
ASSOCIATED DUCTWORK AND EQUIPMENT. SEE
MECHANICAL FOR ADDITIONAL INFORMATION.
AD32 REMOVE PORTION OF TERAZZO FLOORING DOWN TO
CONCRETE SLAB BELOW TO ACOMMODATE NEW
CONSTRUCTION. PROVIDE SELF-LEVELING FLOOR PATCH
AS REQUIRED AND PREPARE SLAB FOR NEW FINISHES.
AD33 EXISTING LOCKERS TO REMAIN. PROTECT FROM DAMAGE
DURING CONSTRUCTION.
AD34 SAWCUT AND REMOVE PORTION OF EXISTING SLAB FOR
NEW FOOTING. SEE STRUCTURAL FOR ADDITIONAL
INFORMATION.
SCALE: 1/8" = 1'-0"
UNIT C - FIRST FLOOR DEMOLITION PLAN
SCALE: 1/8" = 1'-0"
UNIT C - FIRST FLOOR ARCHITECTURAL PLAN PLANNORTHREV.
NO.DESCRIPTION DATE