Loading...
HomeMy WebLinkAbout07020014 Site Plan , Note: This drawing is based on construction plans or record drawings, and is not based upon 0 field survey. The Schneider Corporation does not warrant the accuracy or sufficiency of this information. Contractors should verify existing conditions pdor to any construction. Any discrepancy found on this drawing should be reported to The Schneider Corporotion immediately, foiling to do so results in the contractors assumption of all liability. Note: Per Carmel zoning ordinance 26.1.1 : The residential district limits height to twenty-"five feet (25'). however a dwelling may be increased in height to thirty-five feet (35') provided the side and reor yards ore increased an additional one fool (1') for each one foot (1 ') the structure exceeds the first twenty-fi...e feet (25') In helgl\t. The Schneider Corporation 8901 otis Avenue Historic Fort Haniaon IndianapoU., Indiana 46216-1037 317-626-7100 317-826-7200 FAX This Plot Plan Prepared For: R.H. of Indiana Lot # 92 , containing 7,997 SJ.:t, in Stanford PorII Section # 1 INSlR. # 200500009385 P.C. # 3, Slide # sn CERllACA 1E of CORRECllON INSlR. # 200500044195 aay Twp, HamDton County Sec 29, T18N, R3E -3450 Millbrae-Drive~ ~(50'R/W) Cannel, IN 46074 Prepared Date: 01/30/07: By: AMA Proposed Buyer(s): INVENTORY Community Restrictions: Side Yard :3' min. Rear Yard: N/A Aggregate = 6' (S.H.) R.H. af Indiona Finished Floor Elevation Information Pad Grade = 918.6 per record drawing Pod Grode + 0.7' = Garage FFE (919.3) Gorage FFE + 1.5' = Residential FFE (920.8) Residential FFE - g.O' = Bosement FFE (911.8) ORI'I\:W^ Y SlOPE = 6.41. Note: The garage finished floor elevation is 2,3' above the curb at the drive, per plan. Note: The basement ejevotion, depicted hereon, has been determined and based 'on the pod grades ond/OI'" contours token from the construction plans for this subdivision. Unless stated, no information about fluctuating water tables, soil conditions, or son t)fl6S has been provided or stated on said plans. This lot is located near a body of water. lot or son conditions may require that the basement floor ele\((1tion tle httd 2 loot ooo'o'e r\om\al pool elevation. Site Investigation may be needed if water is encountered during the excavation process or if other known water elevotion 01' sons conditions are present. Investigatioo and any remedial procedures is at the disa-etion of the builder to determine and toke appropriate steps of action, If any ground watl!l" is encountered during excavation the bu~der is encouraged to contact The Schneider CorpOl'ation to disctJsspossible courses of action. Note: Sump'pump(s) to be placed by builder os needed. 0Ppl SIR. # 720 TC=917,79 PER RECORO DRA'MNG Engineerin& Sun,,... Landscape Architecture GIS 'US GoolaiY Plot Pion Legend []QQ]J Proposed Grades 000,0 Ex'lsting Grades __000,0-- Contour Grode * Approx. Lateral Location - . - Sanitary Sewer lines -IT - Storm Sewer lines - IJ - Water Service lines - - - - - - - Sub-Surface Ora'1n lines . Monhole (Sanitary or Storm) .. Beehive Inlet (Storm) IIIlI Curb Inlet (Storm) D End_SesliQnJStor.m) ... Fire H)'Jront - Q Q Q - Q Q 0 - Flow line of swale Building Line (BL / BSL) - - - - - - - Easement line Note: Sanitary Sewer Top of Casting Information Upstream Manhole, TC= 917.79 Downstream Manhole, TC: 918.60 per record drawing Sidewalk to be placed l' from property line, 4' from bock of curb, per plan. Detail of Ground/ Storm Water flow pattern far irldividuallots. Note: Builder to ensure positive drainage away from structure(s). k;R. 0 c (At .~<ts'~-~ .~., 'S, ~",<tSi <\(P ", i.<t P/' <t '00 '.90a~ '-', l'R""'9! '6b 8 </1 <.19' Lot # 92 -Vb07:0067709 ~ ~ =~= ~ Assumed North Scale: ,. = 30' I !~J5.11 37.2' Opit- I~ ~4i- '" ~ ~ sOop;;--' I 0, q-~q l ~^\, V^R. R.O,E. II I Ground Cover Calculations: Orive = 516 SFt Public Wolk =157 SH Privote Walk =51 SFt H)'Jroseeding =3,142 SFt Sod = 272 SYt, from Rear of residence, Optional Sod Pockoge H)'Jroseeding =1,205 SFt Add!. Sod Pkg.= 215 SYt, to Rear easement. 1, s ~I 01'< ~ TYPICAL SWALE SECTION Note: The cootractor is to maintain a minimum distance of ten feet (10') between the sanitry sewer and water line laterals. Flood Hazard Statement: The accuracy of any flood hazard data shown on this report is subject to map scale uncertainty and to any other uncertainty in location or elevation on the referenced flood insurance rate map. ALL of the within described land DOES NOT LIE within that special flood hazard zone A as said land plots by scale on flood insurance rate map # 18057 0205F for City of Carmel, Indian;) (maps dated February 19, 2003). SGN^lURE : D^lE: SIGN^lURE REPRESENTS CONflRM^TION Of RECEIPT Of PLOT PLAN BY CUSTOlIER. FLOOO HAZARO STATEMENT CERTIFICA nON ",\\\\IIII1I1I1I11JI////// ,~\\\\ C. L /' 1'0.0- if" ':J . vi" ~ #' ~'\ ....."".". ,.,'h...~ {':! '..J~'."';"-\S TE:Ff';;", .... A% :3:::: .'''-'-'' N >.,: '. "...., ~ ?1 ~ /~~ 0 O......A:>~ ~:' . ", ~ ~ i 50303 ) ! ~ - . ~ % '. STATE OF ..... ~ '\ <4;>:fvOI A~I':,,""~1 % /1} ..S....U..o.;i\ ~ # ~I/JJI. T\ ~ ,:\\\\$- W//III/IIII1I1I1\\""\ ~lf1l