HomeMy WebLinkAbout8778.00 Aberdeen Plumbing 2023-12-06MECHANICAL SHEET TYPE DESIGNATORSNOT ALL NOTES, DESIGNATORS, SYMBOLS OR ABBREVIATIONS MAY APPLY TO THIS PROJECTSHEET METAL CONNECTION STANDARDSHVAC SYMBOLSPIPING SYMBOLSABBREVIATIONSLINE TYPESMECHANICAL HVAC, PIPING & PLUMBING SYMBOLS AND ABBREVIATIONSGENERAL NOTESSTEAM TRAP DESIGNATIONNOTE SYMBOLSSHEET TITLESHEET TITLEHVAC SHEET TYPE DESIGNATORSPLUMBING SHEET TYPE DESIGNATORS0If bar not 1", adjust scale accordingly.N O R T HNo.DateDescription1234567Estimate No. 12345Drawn by: Justin TischerChecked by: Terry Wilds89101112P001Sheet Number:Page Number: 1 of ?Sheet Title:Original Drawing is 30x42.PLUMBINGKey Plan:TPC Job #: 0-000Sheet Setup Date: 1-16-2023Approved By:ABERDEEN
150 WEST 96TH STREET - INDIANAPOLIS, IN 46260 TPC Mechanical Contractors, LLCP.O. Box 3160 • Carmel, IN 46082317-846-4768Fax 317-846-4788718 EAST GEORGIA STREET, UNIT 357INDIANAPOLIS, INDIANA(317) 525-1716 | JROBINSON@CENDECOLLC.COM10-19-23Issue For PermitC:\Users\justi\OneDrive\TPC\03 Active Projects\Aberdeen\Aberdeen_TPC_2023-10-13.dwg, 10/19/2023 2:04:03 PM
ABCDEFGHJKLMNP1234567891011121314151617181920101EN75<9E67,B8LE106L,F7102H267:A,7,NG103C2A76104A9111D,N,NG111D,N,NG108BACKBA5109BA5D,N,NG02121PA7,2107BA5D,N,NG01119A6HP5,9A7ED,N,NG115MEN
65E67522M114:2MEN
65E67522M116E;P2E;7GB2H112FLE;1172FF,CE105:,NE01110:,NE02E;7GL,48256725AGEE;7GEMPL2<EE5E67522ME;7GMECHELECE;7GC22LE5E;7GF5EE=E5E;7GF5EE=E5E;7GMECHELECE;7GD5<6725AGECONCRETEDEMOBOUNDARYCONCRETEDEMOBOUNDARY4"GW4"GW4"GW 4"GW4
"GWFCOFCOFCOFCOFCO4"SANFCO4"GW
4"SAN4"SAN
4"GW4"GW2"FCO0If bar not 1", adjust scale accordingly.N O R T HNo.DateDescription1234567Estimate No. 12345Drawn by: Justin TischerChecked by: Terry Wilds89101112PD100Sheet Number:Page Number: 1 of ?Sheet Title:Original Drawing is 30x42.PLUMBINGCONCRETE DEMOLITIONKey Plan:TPC Job #: 0-000Sheet Setup Date: 1-16-2023Approved By:718 EAST GEORGIA STREET, UNIT 357INDIANAPOLIS, INDIANA(317) 525-1716 | JROBINSON@CENDECOLLC.COMTPC Mechanical Contractors, LLCP.O. Box 3160 • Carmel, IN 46082317-846-4768Fax 317-846-4788ABERDEEN
150 WEST 96TH STREET - INDIANAPOLIS, IN 4626010-19-23Issue For PermitSCALE 3/16"=1'-0"C:\Users\justi\OneDrive\TPC\03 Active Projects\Aberdeen\Aberdeen_TPC_2023-10-13.dwg, 10/19/2023 2:04:04 PM
ABCDEFGHJKLMNP1234567891011121314151617181920101EN75<9E67,B8LE106L,F7102H267:A,7,NG103C2A76104A9111D,N,NG111D,N,NG108BACKBA5109BA5D,N,NG02121PA7,2107BA5D,N,NG01119A6HP5,9A7ED,N,NG115MEN
65E67522M114:2MEN
65E67522M116E;P2E;7GB2H112FLE;1172FF,CE105:,NE01110:,NE02E;7GL,48256725AGEE;7GEMPL2<EE5E67522ME;7GMECHELECE;7GC22LE5E;7GF5EE=E5E;7GF5EE=E5E;7GMECHELECE;7GD5<6725AGEPLUMBING PLAN KEY NOTES:4"GW4"GW4"GW 4"GW4
"GWFCOFCOFCOFCOFCO4"SANFCO4"GW
4"SAN4"SAN
4"GW4"GW2"FCO0If bar not 1", adjust scale accordingly.N O R T HNo.DateDescription1234567Estimate No. 12345Drawn by: Justin TischerChecked by: Terry Wilds89101112PD101Sheet Number:Page Number: 1 of ?Sheet Title:Original Drawing is 30x42.PLUMBINGUGS DEMOLITIONKey Plan:TPC Job #: 0-000Sheet Setup Date: 1-16-2023Approved By:718 EAST GEORGIA STREET, UNIT 357INDIANAPOLIS, INDIANA(317) 525-1716 | JROBINSON@CENDECOLLC.COMTPC Mechanical Contractors, LLCP.O. Box 3160 • Carmel, IN 46082317-846-4768Fax 317-846-478810-19-23Issue For PermitSCALE 3/16"=1'-0"C:\Users\justi\OneDrive\TPC\03 Active Projects\Aberdeen\Aberdeen_TPC_2023-10-13.dwg, 10/19/2023 2:04:06 PM
Xref R:\8
7
00
-
87
9
9
\8
7
78
.
00
RO
OT
S
TO
CK
HO
SP
I
TA
L
I
TY
G
R
OU
P
-
GR
AN
I
TE
C
IT
Y
C
ON
V
ER
SI
O
N,
I
ND
I
AN
AP
O
LI
S
\0
0
_R
EV
I
T
\1
0
_L
I
NK
S
\0
0
_A
u
t
oC
AD
\
87
7
8.
0
0
R
o
ot
s
t
oc
k
_N
EW
KE
C
.d
wg
ABCDEFGHJKLMNP1234567891011121314151617181920101EN75<9E67,B8LE106L,F7102H267:A,7,NG103C2A76104A9111D,N,NG111D,N,NG108BACKBA5109BA5D,N,NG02121PA7,2107BA5D,N,NG01119A6HP5,9A7ED,N,NG115MEN
65E67522M114:2MEN
65E67522M116E;P2E;7GB2H112FLE;1172FF,CE105:,NE01110:,NE02E;7GL,48256725AGEE;7GEMPL2<EE5E67522ME;7GMECHELECE;7GC22LE5E;7GF5EE=E5E;7GF5EE=E5E;7GMECHELECE;7GD5<6725AGENEW WATER SOFTENER TO BEINSTALLED IN THIS AREA. PIPING TO BERECONFIGURED AND BACK FED TOEXISTING.EXISTING DOMESTICWATER AND FIRE RISERBACKFLOWS AND PIPINGTO REMAINREMOVE EXISTINGWATER HEATER/TMVAND RELOCATECAP EXISTINGHW/SOFT CWAT THIS POINTDEMODEMODEMOSHEETNUMBERVIEWNUMBER3/4" CW HARDTO REMAINDEMO3/4" 140° HW3/4" SCW2" SCW3/4" 140° HW3/4" 140° HW1-1/4" SCW2" CW3/4" HW 140°2" SCW3/4" CW3/4" 140° HW1" SCW3/4" CW3/4" 140° HW1-1/4" SCW3/4" CW3/4" 140° HW3/4" SCW3/4" CW2" V UP/DN3" VTR1"HW3/4"HW3/4"SCW1" SCW3/4" HW 140°1" HW 180°3/4"HW3/4"HW
3/4"HW3/4"SCW3/4"CW 2"SCW
3/4"HW 3/4"SCW3/4" HW/CWUNDERGROUNDUNDERGROUND PIPINGTERMINATION OMMITED FORCLARITY. FED FROM OVERHEAD.TYP.1/2" HW/CW1/2" HW/CWUNDERGROUND3/4" HW/CW1/2" HW/CWUNDERGROUND0If bar not 1", adjust scale accordingly.N O R T HNo.DateDescription1234567Estimate No. 12345Drawn by: Justin TischerChecked by: Terry Wilds89101112PD101Sheet Number:Page Number: 1 of ?Sheet Title:Original Drawing is 30x42.PLUMBINGDOMESTIC WATERDEMOLITIONKey Plan:TPC Job #: 0-000Sheet Setup Date: 1-16-2023Approved By:718 EAST GEORGIA STREET, UNIT 357INDIANAPOLIS, INDIANA(317) 525-1716 | JROBINSON@CENDECOLLC.COMTPC Mechanical Contractors, LLCP.O. Box 3160 • Carmel, IN 46082317-846-4768Fax 317-846-4788ABERDEEN
150 WEST 96TH STREET - INDIANAPOLIS, IN 46260SCALE 3/16"=1'-0"10-19-23Issue For PermitC:\Users\justi\OneDrive\TPC\03 Active Projects\Aberdeen\Aberdeen_TPC_2023-10-13.dwg, 10/19/2023 2:04:08 PM
Xref R:\
8
70
0
-
87
99
\
8
77
8
.0
0
R
O
OT
ST
OC
K
H
O
SP
I
TA
L
IT
Y
G
RO
UP
-
G
R
AN
I
TE
CI
T
Y
C
ON
VE
RS
I
ON
,
IN
D
IA
NA
P
OL
I
S
\0
0_
R
EV
I
T
\1
0_
L
I
NK
S
\0
0
_A
u
to
CA
D
\8
7
78
.
0
0
R
oo
t
s
to
c
k_
NE
W
K
EC
.
d
wg
ABCDEFGHJKLMNP1234567891011121314151617181920101EN75<9E67,B8LE106L,F7102H267:A,7,NG103C2A76104A9111D,N,NG111D,N,NG108BACKBA5109BA5D,N,NG02121PA7,2107BA5D,N,NG01119A6HP5,9A7ED,N,NG115MEN
65E67522M114:2MEN
65E67522M116E;P2E;7GB2H112FLE;1172FF,CE105:,NE01110:,NE02E;7GL,48256725AGEE;7GEMPL2<EE5E67522ME;7GMECHELECE;7GC22LE5E;7GF5EE=E5E;7GF5EE=E5E;7GMECHELECE;7GD5<6725AGE2" V UP/DN2" V UP/DN3" VTRFS-1FS-1FS-1FS-1FS-1FCOFS-12" UP2" UGV2" UP2" V UP/DN3" VTR2" UP2" V UP/DN3" VTR2" UGVCAP4"GW4"GW4"GW 4"GW4
"GWFCOFCOFCOFCOFCO4"SANFCO4"GW
4"SAN4"SAN
4"GW4"GW3"2"4"4"3"3"3"FD-12"FCOFS-1FS-1FS-1FS-1FS-1FS-1FS-1FS-1FS-1FS-1FD-12"2"2" AGV0If bar not 1", adjust scale accordingly.N O R T HNo.DateDescription1234567Estimate No. 12345Drawn by: Justin TischerChecked by: Terry Wilds89101112P100Sheet Number:Page Number: 1 of ?Sheet Title:Original Drawing is 30x42.PLUMBINGUNDERGROUND SANITARYKey Plan:TPC Job #: 0-000Sheet Setup Date: 1-16-2023Approved By:718 EAST GEORGIA STREET, UNIT 357INDIANAPOLIS, INDIANA(317) 525-1716 | JROBINSON@CENDECOLLC.COMTPC Mechanical Contractors, LLCP.O. Box 3160 • Carmel, IN 46082317-846-4768Fax 317-846-4788ABERDEEN
150 WEST 96TH STREET - INDIANAPOLIS, IN 4626010-19-23Issue For PermitSCALE 3/16"=1'-0"C:\Users\justi\OneDrive\TPC\03 Active Projects\Aberdeen\Aberdeen_TPC_2023-10-13.dwg, 10/19/2023 2:04:10 PM
Xref R:\8
7
00
-
87
9
9
\8
7
78
.
00
RO
OT
S
TO
CK
HO
SP
I
TA
L
I
TY
G
R
OU
P
-
GR
AN
I
TE
C
IT
Y
C
ON
V
ER
SI
O
N,
I
ND
I
AN
AP
O
LI
S
\0
0
_R
EV
I
T
\1
0
_L
I
NK
S
\0
0
_A
u
t
oC
AD
\
87
7
8.
0
0
R
o
ot
s
t
oc
k
_N
EW
KE
C
.d
wg
ABCDEFGHJKLMNP1234567891011121314151617181920101EN75<9E67,B8LE106L,F7102H267:A,7,NG103C2A76104A9111D,N,NG111D,N,NG108BACKBA5109BA5D,N,NG02121PA7,2107BA5D,N,NG01119A6HP5,9A7ED,N,NG115MEN
65E67522M114:2MEN
65E67522M116E;P2E;7GB2H112FLE;1172FF,CE105:,NE01110:,NE02E;7GL,48256725AGEE;7GEMPL2<EE5E67522ME;7GMECHELECE;7GC22LE5E;7GF5EE=E5E;7GF5EE=E5E;7GMECHELECE;7GD5<6725AGENEW WATER SOFTENER TO BEINSTALLED IN THIS AREA. PIPING TO BERECONFIGURED AND BACK FED TOEXISTING.EXISTING DOMESTICWATER AND FIRE RISERBACKFLOWS AND PIPINGTO REMAINREMOVE EXISTINGWATER HEATER/TMVAND RELOCATECAP EXISTINGHW/SOFT CWAT THIS POINTSHEETNUMBERVIEWNUMBER3/4" CW HARDTO REMAIN3/4" 140° HW3/4" SCW2" SCW3/4" 140° HW3/4" 140° HW1-1/4" SCW2" CW3/4" HW 140°2" SCW3/4" CW3/4" 140° HW1" SCW3/4" CW3/4" 140° HW1-1/4" SCW3/4" CW3/4" 140° HW3/4" SCW3/4" CW2" V UP/DN3" VTR1"HW3/4"HW3/4"SCW1" SCW3/4" HW 140°1" HW 180°3/4"HW3/4"HW
3/4"HW3/4"SCW3/4"CW 2"SCW
3/4" HW/CWUNDERGROUNDUNDERGROUND PIPINGTERMINATION OMMITED FORCLARITY. FED FROM OVERHEAD.TYP.1/2" HW/CW1/2" HW/CWUNDERGROUND3/4" HW/CW1/2" HW/CWUNDERGROUND0If bar not 1", adjust scale accordingly.N O R T HNo.DateDescription1234567Estimate No. 12345Drawn by: Justin TischerChecked by: Terry Wilds89101112P101Sheet Number:Page Number: 1 of ?Sheet Title:Original Drawing is 30x42.PLUMBINGDOMESTIC WATERKey Plan:TPC Job #: 0-000Sheet Setup Date: 1-16-2023Approved By:718 EAST GEORGIA STREET, UNIT 357INDIANAPOLIS, INDIANA(317) 525-1716 | JROBINSON@CENDECOLLC.COMTPC Mechanical Contractors, LLCP.O. Box 3160 • Carmel, IN 46082317-846-4768Fax 317-846-4788ABERDEEN
150 WEST 96TH STREET - INDIANAPOLIS, IN 4626010-19-23Issue For PermitSCALE 3/16"=1'-0"C:\Users\justi\OneDrive\TPC\03 Active Projects\Aberdeen\Aberdeen_TPC_2023-10-13.dwg, 10/19/2023 2:04:12 PM
GENERAL PLUMBING NOTES1.CONTRACTOR SHALL CONTACT AND COORDINATE WITH ALL APPLICABLE UTILITIES, VERIFY AND BE RESPONSIBLE FOR ANY AND ALL FEES ASSOCIATED WITH INSTALLATION OFPLUMBING SYSTEMS.2.CONTRACTOR SHALL VERIFY EXISTING CONDITIONS AND EXISTING UTILITY SERVICE LOCATIONS PRIOR TO COMMENCING WORK. NOTIFY CONSTRUCTION MANAGER OF ANYINCONSISTENCIES WITH THE PLANS AND SPECIFICATIONS.3.PLUMBING AND PIPING SYSTEMS SHALL BE INSTALLED COMPLETE PER ALL APPLICABLE STATE AND LOCAL CODES. ALL MATERIALS, FIXTURES, DEVICES SHALL BE SUBMITTED FORAPPROVAL TO ADMINISTRATIVE AUTHORITY AND SHALL CONFORM TO APPLICABLE STANDARDS AND BE FREE FROM DEFECTS PER INDIANA IPC 301.1.1. TEST SYSTEM PER 2012 IPC IAC16-1.44.PROVIDE ALL REQUIRED WASTE, VENT, FLEX CONNECTIONS, GUAGES, SHUT-OFF VALVES, UNIONS AS REQUIRED FOR EACH FIXTURE TO MAKE A WORKING SYSTEM.5.REFER TO ARCHITECTURAL AND SITE CIVIL DRAWINGS FOR EXACT LOCATIONS OF PIPING AND FIXTURES AND/OR ADDITIONAL PLUMBING DETAILS. DO NOT SCALE THESE DRAWINGS.6.PIPE ROUTING IS DIAGRAMMATIC. CONTRACTOR SHALL MAKE ROUTING CHANGES AS REQUIRED TO COORDINATE WITH OTHER TRADES.7.ALL PIPE SIZES SHOWN ON DRAWINGS OR SCHEDULED ARE MINIMUM SIZES.8.OVERHEAD PIPING SHALL BE HELD TIGHT TO UNDERSIDE OF STRUCTURAL MEMBERS EXCEPT WHEN IN CONFLICT WITH OTHER TRADES OR OTHERWISE NOTED ON THE PLANS.9.UNDERSLAB SANITARY PIPING SHALL BE SCH. 40 PVC & PITCHED MINIMUM OF 1/8" PER FOOT. ABOVE GRADE SANITARY/VENT PIPING SHALL BE NO-HUB CAST IRON OR SCH. 40 PVC PIPEWITH ARMAFLEX FLAME SPREAD COVERING IN RETURN AIR PLENUMS. COMPLY WITH ANSI/ASTM REQUIREMENTS WASTE, VENT, DRAIN PIPE SHALL COMPLY WITH 2012 IPC 675 IAC 16-1.4701.0 TO 706.010.PROVIDE WATER HAMMER ARRESTORS FOR EACH RESTROOM FIXTURE GROUP UPSTREAM OF LAST FIXTURE.11.HOT AND COLD WATER PIPING ABOVE GRADE SHALL BE "L" HARD DRAWN COPPER PER 2012 IPC 16-1.4 604.0 TO 608.0 PIPING SIZED PER 2012 IPC 16-1.4 INSTALL PIPING SO THAT THEENTIRE SYSTEM CAN BE DRAINED. INSTALL CHROME ESCUTCHEON PLATES AT ALL WALL/CABINET PENETRATIONS.12.ALL HOT AND COLD WATER PIPING LOCATED ABOVE CEILINGS, ON PERIMETER AND INTERIOR WALLS, AND EXPOSED SHALL BE INSULATED WITH 1/2" ARMAFLEX. ALL WATER PIPINGSUBJECTED TO BELOW FREEZING TEMPERATURES SHALL BE INSTALLED WITH ELECTRIC HEAT TRACE SIMILAR TO "FROSTEX PLUS 9600" ALL EXPOSED VISUAL WATER PIPING SHALLHAVE WHITE PVC JACKETING.13.PROVIDE ACCESS PANELS WHERE CONTROL DEVICES, VALVES, CLEANOUTS, ETC. ARE CONCEALED WIITHIN WALLS AND CEILINGS.14.TEST WATER SYSTEM UNDER 150 PSIG COMPRESSED AIR PRESSURE FOR A MIN. OF 4 HOURS.15.COMPLY WITH ALL ADA REQUIREMENTS.16.ALL PLUMBING FIXTURES SHALL BE INSTALLED PER STATE CODE IPC 402 AND TABLE 4.1 FOR WATER CONSERVING FIXTURES AND FITTINGS. ALL FIXTURES SHALL COMPLY WITH 2012IPC SECTION IAC 16-1.4, 401.0 TO 420.0 AND TABLE 403.1.17.ALL NON-FERROUS PIPE LOCATED IN RETURN PLENUMS SHALL MEET NFPA 90A WITH FLAME SPREAD RATING UNDER 25 AND SMOKE DEVELOPED RATING UNDER 50 WITH APPROPRIATEPIPE COVERING.18.ALL PUBLIC HAND WASH SINK SHALL COMPLY WITH 2012 IPC SECTION 416.5 TO HAVE THERMOSTATIC MIXING DEVICE ON HOT WATER.19.PROVIDE RUBBER WATERLESS TRAP SEALER FOR ALL FLOOR DRAINS.20.ALL PLUMBING VENT STACKS SHALL BE PLACED A MIN. OF 10'-0" FROM ANY FRESH AIR INTAKES.PLUMBING FIXTURE SCHEDULEMARKTYPESERVICEMODEL OREQUALMIN. WASTECONNMIN. VENTCONNMIN. CWCONNMIN. HWCONNREMARKSFS-1FLOOR SINKVARIOUSJR SMITH3100-Y03-123"--SQUARE NICKEL BRONZE 8 1/2" TOPFD-1FLOOR DRAINVARIOUSJR SMITH2005-Y03-B3"---NICKEL BRONZE TOP0If bar not 1", adjust scale accordingly.N O R T HNo.DateDescription1234567Estimate No. 12345Drawn by: Justin TischerChecked by: Terry Wilds89101112P500Sheet Number:Page Number: 1 of ?Sheet Title:Original Drawing is 30x42.PLUMBING SCHEDULES &DETAILSKey Plan:TPC Job #: 0-000Sheet Setup Date: 1-16-2023Approved By:718 EAST GEORGIA STREET, UNIT 357INDIANAPOLIS, INDIANA(317) 525-1716 | JROBINSON@CENDECOLLC.COMTPC Mechanical Contractors, LLCP.O. Box 3160 • Carmel, IN 46082317-846-4768Fax 317-846-4788ABERDEEN
150 WEST 96TH STREET - INDIANAPOLIS, IN 4626010-19-23Issue For PermitC:\Users\justi\OneDrive\TPC\03 Active Projects\Aberdeen\Aberdeen_TPC_2023-10-13.dwg, 10/19/2023 2:04:14 PM