HomeMy WebLinkAboutElectrical Floor PlansELECTRICAL LEGEND:
110V DUPLEX RECEPTACLE
®
CABLE TV OUTLET
AT 18 A.F.F. U.N.O.
GFI
110V DUPLEX RECEPTACLE
m
JUNCTION BOX
WITH GROUND FAULT
INTERRUPT AT 18" A.F.F., U.N.O.
00.
DATA JACK
0 WP
WEATHERPROOF 110V DUPLEX RECEPTACLE
[r]
DISCONNECT
AT 18" A.F.F. U.N.O.
220V DUPLEX RECEPTACLE
,�,
SMOKE DETECTOR. ALL SMOKE DETECTORS
SHALL BE HARDWIRED AND
SWITCH
INTERCONNECTED.
COMBINATION SMOKE AND CARBON
3
3 WAY SWITCH
MONOXIDE DETECTOR. ALL SMOKE
DETECTORS SHALL BE HARDWIRED AND
4
4 WAY SWITCH
INTERCONNECTED.
D
DIMMABLE SWITCH
CEILING FAN WITH LIGHT KIT
O
6" CAN LIGHT FIXTURE
WALL MOUNTED LIGHT FIXTURE
PENDANT LIGHT
®
CAN LIGHT/EXHAUST FAN COMBO
®
SURFACE LIGHT/EXHAUST FAN COMBO
L- - - - - - - - - - - - - - - - - - - - - - - - - - - J
� BASEMENT ELECTRICAL PLAN
NORTH0 21 41 81 12'
ROTTMFinn l COLLIER
ARCHITECTS
155 EAST MARKET STREET
SUITE 200
INDIANAPOLIS, INDIANA 46204
T 317.721.2724
ROTTMANNCOLLIER.COM
15)
NO.
9600173
STATE OF _ '*
•' • !NpI ANP:
SCOPE DOCUMENT
THESE DOCUMENTS INDICATE THE GENERAL
SCOPE OF THE PROJECT IN TERMS OF
ARCHITECTURAL DESIGN CONCEPT, DIMENSIONS
OF THE BUILDING, MAJOR ARCHITECTURAL
ELEMENTS AND TYPE OF STRUCTURAL,
MECHANICAL AND ELECTRICAL SYSTEMS. THE
DRAWINGS DO NOT NECESSARILY INDICATE OR
DESCRIBE ALL WORK REQUIRED FOR FULL
PERFORMANCE AND COMPLETION OF THE
REQUIREMENTS OF THE CONTRACT. ON THE
BASIS OF THE GENERAL SCOPE INDICATED OR
DESCRIBED, TRADE CONTRACTOR SHALL
FURNISH ALL ITEMS REQUIRED FOR PROPER
EXECUTION AND COMPLETION OF THE WORK
0
z
0
0
0
Q
0
z
Q
J
W
2
W
Ir
W
L`
_
Z
Z
W
�
�o
Z
W
Z
w
a
z
Q
Q
z
Z
W
to
r
o
J
W
a
N
L)
z�
=m
0
REVISIONS
11-20-2023 CONSTRUCTION SET
BASEMENT
ELECTRICAL PLAN
PROJECT NO 21117
DATE 11-20-2023
SHEET
ELECTI -_-AL LEGEND:
11OV DUPLEX RECEPTACLE
®
CABLE TV OUTLET
AT 18" A.F.F. U.N.O.
GFI
11OV DUPLEX RECEPTACLE
m
JUNCTION BOX
WITH GROUND FAULT
INTERRUPT AT 18" A.F.F., U.N.O.
,
DATA JACK
WP
WEATHERPROOF 110V DUPLEX RECEPTACLE
�]
DISCONNECT
AT 18" A.F.F. U.N.O.
Air
YY
220V DUPLEX RECEPTACLE
SMOKE DETECTOR. ALL SMOKE DETECTORS
SHALL BE HARDWIRED AND
SWITCH
INTERCONNECTED.
COMBINATION SMOKE AND CARBON
3
3 WAY SWITCH
MONOXIDE DETECTOR. ALL SMOKE
DETECTORS SHALL BE HARDWIRED AND
4
4 WAY SWITCH
INTERCONNECTED.
D
DIMMABLE SWITCH
CEILING FAN WITH LIGHT KIT
O
6" CAN LIGHT FIXTURE
WALL MOUNTED LIGHT FIXTURE
PENDANT LIGHT
®
CAN LIGHT/EXHAUST FAN COMBO
ra
SURFACE LIGHT/EXHAUST FAN COMBO
ROTTMRnn l COLLIER
ARCHITECTS
155 EAST MARKET STREET
SUITE 200
INDIANAPOLIS, INDIANA 46204
T 317.721.2724
ROTTMANNCOLLIER.COM
04 NO. RFo'�2
-�Z-
9600173 =
;* STATE OF
Rc.... G
Odd
SCOPE DOCUMENT
THESE DOCUMENTS INDICATE THE GENERAL
SCOPE OF THE PROJECT IN TERMS OF
ARCHITECTURAL DESIGN CONCEPT, DIMENSIONS
OF THE BUILDING, MAJOR ARCHITECTURAL
ELEMENTS AND TYPE OF STRUCTURAL,
MECHANICAL AND ELECTRICAL SYSTEMS. THE
DRAWINGS DO NOT NECESSARILY INDICATE OR
DESCRIBE ALL WORK REQUIRED FOR FULL
PERFORMANCE AND COMPLETION OF THE
REQUIREMENTS OF THE CONTRACT. ON THE
BASIS OF THE GENERAL SCOPE INDICATED OR
DESCRIBED, TRADE CONTRACTOR SHALL
FURNISH ALL ITEMS REQUIRED FOR PROPER
EXECUTION AND COMPLETION OF THE WORK
Iz
0
z
O
0
0
Q
0
z
Q
J
LEI
LLI
cr-
0
ir
Lv
LL.
_
Z
Z
�o
Lv
O
Z
W�
Z
Wa
z
Z
NII
>
az
Z
'w
O
N
Q
EMMA-
V
Lu
of u
®IIIIY',"II'�G.
e�llb�
REVISIONS
11-20-2023
CONSTRUCTION SEf
FIRST FLOOR
ELECTRICAL PLAN
PROJECT NO
21117
DATE
11-20-2023
Q, STF ®Ig 11FI
L 4 v
NQ,-- R TH 1 /4„ = 1,_0„
SHEET
E L E TI _ AL LE -1\1
11OV DUPLEX RECEPTACLE ®
AT 18" A.F.F. U.N.O.
CABLE TV OUTLET
GFI 11 OV DUPLEX RECEPTACLE m
JUNCTION BOX
WITH GROUND FAULT
INTERRUPT AT 18" A.F.F., U.N.O. ,
DATA JACK
WID WEATHERPROOF 110V DUPLEX RECEPTACLE
AT 18" A.F.F. U.N.O.
DISCONNECT
hl� 220V DUPLEX RECEPTACLE
YY
SMOKE DETECTOR. ALL SMOKE DETECTORS
SHALL BE HARDWIRED AND
SWITCH
INTERCONNECTED.
3 3 WAY SWITCH
COMBINATION SMOKE AND CARBON
MONOXIDE DETECTOR. ALL SMOKE
DETECTORS SHALL BE HARDWIRED AND
4 4 WAY SWITCH
INTERCONNECTED.
D DIMMABLE SWITCH
CEILING FAN WITH LIGHT KIT
O 6" CAN LIGHT FIXTURE
WALL MOUNTED LIGHT FIXTURE
PENDANT LIGHT
® CAN LIGHT/EXHAUST FAN COMBO
pm SURFACE LIGHT/EXHAUST FAN COMBO
IF NEEDED FOR BASEMENT
WID AND/OR ADDITION
GFI
2
3
I
/C /
I
3 3
3
W/D
I
I
GFI4
..
+44
GFI
I
I
/
\
/
WP
\
I
/
GFI
\
I
I
+44
GFI
REF
—
— — — —
- — — — —
— — —
+4
GFI
3D F
DISPOSAL
v El
+44
GFI
�
S
� I
+30"
MICRO.
I
4
ON CEILING FOR
GARAGE DOOR
+44 WP
GFI GFI
+30
FURN
WH I
/ I
I \
I
WP
GFI +44
/
I
GFI
I
\
/ I
I
/
I
I
I
I
PC
'
4'
$' 12'
$' 12'
NORTH
NORTH
�®N-- -ELE"I A
ARAGE FIRST F
ELEC. PLAN
c
c
- / ®
-�
1 /4" = 1'-0"
1 /4" = 1'-0"
ROTTMRnn l COLLIER
ARCHITECTS
155 EAST MARKET STREET
SUITE 200
INDIANAPOLIS, INDIANA 46204
T 317.721.2724
ROTTMANNCOLLIER.COM
NO
-� Z-
9600173 =
;* STATE OF
�ND I ANP:'�
vlf�� Ui/
SCOPE DOCUMENT
THESE DOCUMENTS INDICATE THE GENERAL
SCOPE OF THE PROJECT IN TERMS OF
ARCHITECTURAL DESIGN CONCEPT, DIMENSIONS
OF THE BUILDING, MAJOR ARCHITECTURAL
ELEMENTS AND TYPE OF STRUCTURAL,
MECHANICAL AND ELECTRICAL SYSTEMS. THE
DRAWINGS DO NOT NECESSARILY INDICATE OR
DESCRIBE ALL WORK REQUIRED FOR FULL
PERFORMANCE AND COMPLETION OF THE
REQUIREMENTS OF THE CONTRACT. ON THE
BASIS OF THE GENERAL SCOPE INDICATED OR
DESCRIBED, TRADE CONTRACTOR SHALL
FURNISH ALL ITEMS REQUIRED FOR PROPER
EXECUTION AND COMPLETION OF THE WORK
ir
W
O
Z
�
p
Z
N
O
W�Z�
O
a
W�
�a
w
Z
O
Z
Q
,�i�� II,i��iN il�� ,
>
Q
a
Z
W
W
r-1
O_
N
LLI
Q
V
7
Lu
tVVi"
REVISIONS
11-20-2023
CONSTRUCTION SEf
GARAGE
ELECTRICAL
PLANS
PROJECT NO
21117
DATE
11-20-2023
SHEET