Loading...
HomeMy WebLinkAbout07020026 Site Plan ~~ The Schneider Corporation . 6001 ou. Avenue Historic Fort H81Tison Indianapolis, Indiana 48216-1037 317-826-7100 Schneider 317-626-72~1 FAX This Plot Plan Prepared for: R.H. of Indiana Lot # 244 , containing 13,166 S.F.:!:, in aa)boume Section # J INSlR. # 200400080247 P,C. # J, Slide # 5JJ Hamilton County, aay Twp Sec 30, TIaN, ROJE 13187 Salamone Way (50' R/W) Carmel, IN__460I4 _ _ __ _ Prepared Oate: 01/24/07: By: AMA Proposed Buyer(s): INVENTORY . EnginlleriDi Surveying Landscape Arcb.itedure GIS .US CealoD' Note: This drawing is based on construction plans or record drawingsj and is not based upon a field survey. The Schneider Corporation does not warrant the accuracy or sufficiency of this information. Contractors should verify existing conditions prior to any construction. Any discrepancy found on this drawing should be reported to The Schneider Corporation immediately; failing to do so results in the contractors assumption of 011 liability. Plot Plan legend []Q[ID Proposed Grades 000.0 Existing Grades __ 000.0- Contour Grade * Approx. Loteral Location - . - $onJlory Sewer Lines -a- Storm Sewer Lines - IJ - Water Service Lines - - - - - - - Sub-Surface Drain Lines . lAanhole (Sanitary or Storm) . Beehive Inlet (Storm) II1II Curb Inlet (Storm) D End Section (Storm) ..... Fire Hydrant - 0" "~ .~o ..=...f1ow.Line oLswale _ Building Line (BL / BSL) - - - - - - - Easement Line Note: The basement elevation, depicted hereon, has been determined and based on the pod grades and/or contours token from the construction plans for this subdivision. Unless stated, no information about fluctuating water tables, so~ conditions, or soil twes has been provided or stated 00 sold plans. This lot is located near 0 body of water. Lot Of so~ cOllditions may require that the basement floor elevation be held 2 foot above normal pool elevation. Site Investigotion may be needed if woter Is encountered during the excavatfon prOCeSS or if other known water elevation or soils conditions ore presenL In'.'estigation and any remedial procedures is at the discretion of the builder -to-determine,ond~toke_oppropr!ate'8teps_of_octlon. If any - ground water is encountered during excavation the builder is encouraged to contact The Schneider ClXporation to discuS5 possible courses of action. Note: Sump pump(s) to be placed by builder os needed. Ground Cover Calculations: Community Restrictions: Drive = 941 SF:!: Side Yard = 5' Public Walk =1,159 SF:! Reor Yord = 20' Private Walk = 9 SF f A99regote = 10' (B.H.) Hydroseeding =5,039 SFf Zoning = SI Sod = 709 Sri, from R.H. of Indiana Rear of residence. Finished Floor Elevation Information Optional Sod Package Pod .Grode = 914.1 per pion Hydroseeding =3,375 SFf Pod Grode + 0.7' = Goroge FFE (914.8) Add!. Sod Pkg.= f85 Sri, to Garoge FFE + 1.5' = Residential FfE (916.3) Reor oosement. Residentiol FFE - 9.0' = Basement FFE (907.3) ORI-,rWAY SlOPE = 3.3~ Note: The garage finished floor ~e"'ation is 2.2' above the curt at the drive, per pion. Sidewalk to be placed l' from property line, 4' from bock of curb, per pion. w~' N , ~ , 'Wffil ~a..: , , , '" N 0; wg en r-- m ~ a 1ii1 ~ G,6!J1,;. SIR. # 66 TC=914.47 PER RECORD ORA\\1NG 30.0' B-B Note: Per Carmel zoning ordinance 26.1.1 : The residential district limits height to twenty-five feet (25'), however a dwelling may be increased in height to thirty-five feet (35') provided the side and reor yards ore increased on odditiQflal one foot (1') for each one foot (1') the structure exceeds the first twenty-five feet (25') in height. Lot # 244 Vb07.0067613 Note: Sanitary Sewer Top of Casting Information Upstroom Manhme, TC= 912.73 Downstream Manhole, TC= 914.47 per recard drawing Detaff of Ground/ Storm Water flow pattern for individual lots. ~Lm =~= Note: Builder to ensure positive drainage away from strudure{s). ~ ~-r---- ---- ------------- ~~~. TEAGUE PLACE Assumed North Scale: ," = 30' I , 'r' -------- ~~R~~N ---- Ii > ~ D , , , , I '> *1 -g~ J 8P d ;!I\ ""- - ~ r-- .....'" .00' ~ ~I r- p '" .36.0' ~ 26.0'1 I ,.-; : 1 ~ 0; '> , 17611 ~J 1 U;.i ~I '" ~ ROll CURB ~ ~ 5' WALK 115.00' J\ IT 25' DU&SE !;l \ 25' BL \ \ 32.75' ~>l~ ~ "',,;:; m o~~ !.: !i'Vl~ 0 ~-<i <':o! <> 4. "" ~~ i!? ::; '" z ~ ~ !;l ~ ~ 3.4' .33.4' Note: The contractor is to maintain a minimum distance of ten feet (10') between the sanitary sewer and water line laterals. This drawing is not intended to be represented as a retracement or original boundary survey, a route survey, or a Surveyor Location Report. l 26.0' -L '" ;:; 31.0' ~ m '" 0<> "'>1 3.00' ";,.., ~- !ii~ 8. 25.00 ?i~ ~~ 56.38' ~.. TC-911.59 PER PLAN TEAGUE F 50' R/ ~. , 4, cr t- . OPt -;.... 4~i 5\..oe T'rPICAl SWALE SECTION DATE: F=lood Hazard Statement: The accuracy of any flood hazard data shown on this report is subject to map scale uncertainty and to any other uncertainty in location or elevation on the referenced flood insurance rate map. ALL of the within described land DOES NOT lie within that special flood hazard zone AE as said land plots by scale on flood insurance rate map #1800810205 F for the City of Carmel, Indiana dated February 19, 2003. ~GNATURE REPRESENTS CON~R~ATION OF RECEIPT OF PLOT PLAN BY CUSTOMER. ~ ... -'- -'- 50.00' ~19 ~GNA TURE : TC=912.20 PER PLAN \ \' .0 ~ Li') 0) ~ :,[ \ 'i\\~ cl \'5> 'it '" 1" \ OS ~\ 9-\ fi,\ \ " 0.00' 0; 2B.: .0) r-- ~ c.ci ...- => Q '" []ill] 6.3' !;l 140.00 =: 32.75' iI:_ ~>l!;l ~"'" "'.r 67.4' FLOOD HAZARD STATEMENT CERTlFICA TlON \\\\\\\\1111111111111111111 ~."""c. L ~!/% #' ~~ ......:.... fJ'rh~ ff ~ ......0 \s T E: 4?-.... 0/".,..<>% f!!c::::.....'<-'v No o....;<:>~ 2:." . ". ::=. ~ ( 50303 j I ?: ..... STATE OF ./ @ ~ /". ..' it ~(~"..:tvDIA~':"""~~ ~ '4tJ '''S'''U'''R'\i\.:-l\ # ~0/!. '1 \\'Y-~ 11111/111111111111\\\\\\\\' ~l.~