HomeMy WebLinkAbout07020026 Site Plan
~~ The Schneider Corporation
. 6001 ou. Avenue
Historic Fort H81Tison
Indianapolis, Indiana 48216-1037
317-826-7100
Schneider 317-626-72~1 FAX
This Plot Plan Prepared for: R.H. of Indiana
Lot # 244 , containing 13,166 S.F.:!:, in
aa)boume
Section # J
INSlR. # 200400080247
P,C. # J, Slide # 5JJ
Hamilton County, aay Twp
Sec 30, TIaN, ROJE
13187 Salamone Way (50' R/W)
Carmel, IN__460I4 _ _ __ _
Prepared Oate: 01/24/07: By: AMA
Proposed Buyer(s): INVENTORY
.
EnginlleriDi
Surveying
Landscape Arcb.itedure
GIS .US
CealoD'
Note:
This drawing is based on construction plans or record
drawingsj and is not based upon a field survey. The
Schneider Corporation does not warrant the accuracy or
sufficiency of this information. Contractors should verify
existing conditions prior to any construction. Any
discrepancy found on this drawing should be reported to
The Schneider Corporation immediately; failing to do so
results in the contractors assumption of 011 liability.
Plot Plan legend
[]Q[ID Proposed Grades
000.0 Existing Grades
__ 000.0- Contour Grade
* Approx. Loteral Location
- . - $onJlory Sewer Lines
-a- Storm Sewer Lines
- IJ - Water Service Lines
- - - - - - - Sub-Surface Drain Lines
. lAanhole (Sanitary or Storm)
. Beehive Inlet (Storm)
II1II Curb Inlet (Storm)
D End Section (Storm)
..... Fire Hydrant
- 0" "~ .~o ..=...f1ow.Line oLswale _
Building Line (BL / BSL)
- - - - - - - Easement Line
Note:
The basement elevation, depicted hereon, has been determined and
based on the pod grades and/or contours token from the construction
plans for this subdivision. Unless stated, no information about
fluctuating water tables, so~ conditions, or soil twes has been
provided or stated 00 sold plans. This lot is located near 0 body of
water. Lot Of so~ cOllditions may require that the basement floor
elevation be held 2 foot above normal pool elevation. Site Investigotion
may be needed if woter Is encountered during the excavatfon prOCeSS
or if other known water elevation or soils conditions ore presenL
In'.'estigation and any remedial procedures is at the discretion of the
builder -to-determine,ond~toke_oppropr!ate'8teps_of_octlon. If any -
ground water is encountered during excavation the builder is
encouraged to contact The Schneider ClXporation to discuS5 possible
courses of action.
Note: Sump pump(s) to be
placed by builder os needed.
Ground Cover Calculations:
Community Restrictions: Drive = 941 SF:!:
Side Yard = 5' Public Walk =1,159 SF:!
Reor Yord = 20' Private Walk = 9 SF f
A99regote = 10' (B.H.) Hydroseeding =5,039 SFf
Zoning = SI Sod = 709 Sri, from
R.H. of Indiana Rear of residence.
Finished Floor Elevation Information Optional Sod Package
Pod .Grode = 914.1 per pion Hydroseeding =3,375 SFf
Pod Grode + 0.7' = Goroge FFE (914.8) Add!. Sod Pkg.= f85 Sri, to
Garoge FFE + 1.5' = Residential FfE (916.3) Reor oosement.
Residentiol FFE - 9.0' = Basement FFE (907.3)
ORI-,rWAY SlOPE = 3.3~
Note: The garage finished floor ~e"'ation
is 2.2' above the curt at the drive, per pion.
Sidewalk to be placed
l' from property line,
4' from bock of curb,
per pion.
w~'
N ,
~ ,
'Wffil
~a..:
,
,
,
'"
N
0;
wg
en
r--
m
~
a
1ii1
~
G,6!J1,;.
SIR. # 66
TC=914.47
PER RECORD
ORA\\1NG
30.0'
B-B
Note: Per Carmel zoning ordinance 26.1.1 : The
residential district limits height to twenty-five feet (25'),
however a dwelling may be increased in height to
thirty-five feet (35') provided the side and reor yards
ore increased on odditiQflal one foot (1') for each one
foot (1') the structure exceeds the first twenty-five feet
(25') in height.
Lot # 244
Vb07.0067613
Note: Sanitary Sewer
Top of Casting Information
Upstroom Manhme, TC= 912.73
Downstream Manhole, TC= 914.47
per recard drawing
Detaff of Ground/ Storm
Water flow pattern for
individual lots.
~Lm
=~= Note: Builder to ensure positive
drainage away from strudure{s).
~
~-r---- ---- -------------
~~~. TEAGUE PLACE
Assumed North
Scale: ," = 30'
I , 'r'
-------- ~~R~~N ----
Ii
>
~
D
,
,
,
,
I
'>
*1
-g~ J 8P
d ;!I\ ""- -
~ r-- .....'" .00'
~ ~I r- p
'" .36.0' ~
26.0'1
I
,.-;
: 1 ~ 0;
'>
,
17611
~J
1
U;.i
~I
'"
~
ROll CURB
~ ~
5' WALK
115.00' J\
IT
25' DU&SE !;l \
25' BL \
\
32.75'
~>l~ ~
"',,;:; m
o~~ !.:
!i'Vl~
0 ~-<i
<':o! <> 4.
""
~~
i!? ::;
'"
z ~
~
!;l
~
~
3.4'
.33.4'
Note:
The contractor is to maintain a minimum
distance of ten feet (10') between the
sanitary sewer and water line laterals.
This drawing is not intended to be represented as a retracement or
original boundary survey, a route survey, or a Surveyor Location Report.
l
26.0'
-L
'" ;:;
31.0' ~ m
'"
0<>
"'>1 3.00'
";,.., ~-
!ii~
8.
25.00
?i~
~~
56.38'
~..
TC-911.59
PER PLAN
TEAGUE F
50' R/
~.
,
4, cr t-
. OPt -;.... 4~i 5\..oe
T'rPICAl SWALE SECTION
DATE:
F=lood Hazard Statement: The accuracy of any flood hazard data shown on this report is subject to
map scale uncertainty and to any other uncertainty in location or elevation on the referenced flood
insurance rate map. ALL of the within described land DOES NOT lie within that special flood hazard
zone AE as said land plots by scale on flood insurance rate map #1800810205 F for the City of
Carmel, Indiana dated February 19, 2003.
~GNATURE REPRESENTS CON~R~ATION OF RECEIPT OF PLOT PLAN BY CUSTOMER.
~
...
-'- -'-
50.00'
~19
~GNA TURE :
TC=912.20
PER PLAN
\ \'
.0
~
Li')
0)
~
:,[
\
'i\\~
cl \'5>
'it '"
1" \
OS
~\
9-\
fi,\
\ "
0.00' 0;
2B.:
.0)
r-- ~
c.ci
...- =>
Q
'"
[]ill]
6.3' !;l 140.00
=: 32.75'
iI:_ ~>l!;l
~"'"
"'.r
67.4'
FLOOD HAZARD STATEMENT
CERTlFICA TlON
\\\\\\\\1111111111111111111
~."""c. L ~!/%
#' ~~ ......:.... fJ'rh~
ff ~ ......0 \s T E: 4?-.... 0/".,..<>%
f!!c::::.....'<-'v No o....;<:>~
2:." . ". ::=.
~ ( 50303 j I
?: ..... STATE OF ./ @
~ /". ..' it
~(~"..:tvDIA~':"""~~
~ '4tJ '''S'''U'''R'\i\.:-l\ #
~0/!. '1 \\'Y-~
11111/111111111111\\\\\\\\'
~l.~