HomeMy WebLinkAboutAddition C-502 Site DetailsSTRUCTURE NUMBER ST -01 ST -02 DESCRIPTION ST -03 A (1" ST -04 ST -05 ST -06 ST -07 ST -04 DESCRIPTION END SECTION BOX /ADS INLET 6.5" BOX /ADS INLET 780.20± M.E. BOX /ADS INLET CLEANOUT CLEANOUT CLEANOUT BOX /ADS INLET DETAIL NUMBER 3/C -502 2/C -502 2/C -502 2/C -502 4/C -502 4/C -502 4/C -502 2/C -502 STRUCTURE SIZE 15" DIA. 24" x 24" 24" x 24" 24" x 24" 8" DIA. 24" x 24" 8" DIA. 24" x 24" CASTING NUMBER N/A R- 3402 —E R- 3402 —E R- 1883 —G4 CAST IRON /BRONZE CAST IRON /BRONZE CAST IRON /BRONZE R- 3402 —E RIM ELEVATION N/A 776.50 780.00 779.00 780.25 M.E. M.E. 779.00 INVERTS W 772.95 15" DIA. SW 773.82 12" DIA. S 774.16 8" PVC E 773.57 15" DIA. N 774.05 12" C.I.P. N 774.15 12" C.I.P. N 774.40 8" PVC V.I.F. 10" R.D. V.I.F. 10" R.D. N 774.27 12" C.I.P. Pipe Diameter SS -01 Dimensions (inches) DESCRIPTION MANHOLE A (1" B MAX 1/C-502 H (1 (1 L 1/2 W (2 12" 0 HDPE 6.5" 10" 780.20± M.E. 6.5" INVERTS 25" W 778.10 8" DIA. minimum. 29" 15" 0 HDPE 6.5" 10" 6.5" 25" 29" 18" 0 HDPE 7.5" 15" 6.5" 32" 35" STRUCTURE NUMBER SS -01 SS -02 DESCRIPTION MANHOLE CLEANOUT DETAIL NUMBER 1/C-502 4/C -502 STRUCTURE SIZE 8" 8" CASTING NUMBER R- 1510 —A CAST IRON /BRONZE RIM ELEVATION 780.20± M.E. 780.25 INVERTS E 777.48 VIF 8" DIA. S 777.48 VIF 6" DIA. W 777.46 VIF 8" DIA. W 778.10 8" DIA. minimum. fl NOTCH TOP OF PILING r 4 or less or less Guardrail Elevation Scale: 1/2" 1' -0" Within 5' of edge of pavement Within 5' of edge of pavement 5' -0" MAX. 5/8" HD GALV. BOLTS WITH H.D. WASHER AT HEAD AND NUT; INSTALL (2) BOLTS AT POST LOCATIONS BETWEEN PIERS E.O.P., curb, gutter, or similar structure Min. 6" topsoil to ensure grass growth if not under pavement Minimum trench width 1.25x(o.d.) 12" 'B' borrow or equiv.. granular material compacted to 95% standard proctor max. density Pipe, see site plan for type and size Rigid Pipe Bedding Section Not to Scale INSERT AT 1" =1' E.O.P., curb, gutter or similar structure Min. 6" topsoil to ensure grass growth if not under pavement 'B' borrow or equiv. granular material compacted to 95% standard proctor max. density Minimum trench width 1.25x(o.d.) 12" 8 crushed stone or approved equivalent. Class 1 bedding material hand tamped or walked into place. Pipe, see site plan for type and size Flexible Pipe Bedding Section Not to Scale INSERT AT 1" 1 —O" 2 "x2" at 5" O.C. Notes: Notes: 5/8" HD GALV. BOLTS WITH H.D. WASHER AT HEAD AND NUT; INSTALL (2) BOLTS AT POST LOCATIONS BETWEEN PIERS AIIIMIAMMEISSESEEMENETii Bedding and Backfill for water mains shall be sand in lieu of #8 crushed stone. All bedding and initial backfill shall be installed in 6" to 12" balanced lifts. A minimum of 9" of clearance shall be provided on each side of the installed pipe. All bedding and initial backfill shall be installed in 6" to 12" balanced lifts. A minimum of 9" of clearance shall be provided on each side of the installed pipe. Bedding and Backfill for water mains shall be sand in lieu of #8 crushed stone. Typ. Guardrail Section 1 Scale: 1/2" 1' -0" /X Greater than 5' from edge of pavement reater than 5' RAIL 4 "x6" POST 5'- 0 "o.c., EXTEND POST BOTTOM OF 2 "X12" AT PIER LOCATIONS 2 "x6" CAP (ROUND EDGES) 2 "x2" RAIL C� 5 "o.c. 2 "x8" RAIL ti E.O.P., curb, gutter, or similar structure Min. 6" topsoil to ensure grass growth \/"Y Greater than 5' from edge of pavement Minimum trench width 1.25x(o.d.) 12" Regular backfill Pipe, see site plan for type and size 'B' borrow or equiv. granular material compacted to 90% standard proctor max. density E.O.P., curb, gutter, or similar structure Min. 6" topsoil to ensure grass growth \x Regular backfill Minimum trench width 1.25x(o.d.) 12" #8 crushed stone or approved equivalent. Class 1 bedding material hand tamped or walked into place. Pipe, see site plan for type and size SANITARY STRUCTURE TABLE STORM STRUCTURE DATA TABLE J.R. Smith Heavy Duty Cast Iron Cleanout housing and cover, 4250 Series with gasket or approved equal. Exterior Cleanout Detail Not to Scale 4AJ, W J,A Top View Not to Scale 1/8 bend if cleanout occurs at end of line 18" sq. concrete pad trowel smooth and edge (in lawn or landscaped areas) End View Metal HDPE End Section Detail 3 Asphaltic mastic or butyl rubber seal between joints Full height manhole steps as specified 0 —ring gasket asphaltic mastic or butyl rubber seal at joints Base 6" or 8" per section Not to Scale INSERT AT 1" =1' 1# 6 1, See Structure y 6" a Standard Precast Manhole 0 Note: 6" 4000 psi concrete precast or poured in place E Box Inlet Detail Not to Scale Outlet pipe Curb or flat casting, see Profiles Casting frame and cover per Profiles 0 1 11 2' DIA. 111111111111111111111111111111111114k 1 611001 o o p' 0 o 0 Diameter Varies 0 J o 0 o 0 o O 0 p 0 0 00 Precast concrete adjuster rings if needed (4 max.) 5" min. Class "A" concrete a� a Eccentric cone or reducer cap as req'd by site conditions. Cone top to match adjusting ring profile NOTE: Concrete Manhole conforms to ASTM C478. See Construction Specifications for Alternate Materials. Precast concrete section Preformed hole to max. of pipe o.d. 6" with nonshrink cement grout Bench walls at min. per foot slope Manhole base set on 6" of or #2 stone NOTE: Manhole Detail is typical for sanitary and storm manholes except: 1. For sanitary manhole adjusting rings use butyl rubber base exterior backplaster material, j" 1/16" min. thickness, from 2" below top of cone to casting. 2. Manhole joints shall be o —ring gasket plus extrudable gasket (Kent Seal or equal), per ASTM C -443. 3. Connection of pipes to sanitary manholes shall be made using a flexible boot, Kor —n —seal flexible connector, cast —in —place Dura —seal gasket, A —lock gasket, or approved equal. SCHMIDT ASSOCIATES Wil -Fra -Mar Building 320 East Vermont Street Indianapolis, IN 46204 -2126 317 263 -6226 Fax: 317 263 -6224 Project No Project Date Produced Revision Date 2002 -036 March 15, 2004 CEC c ,rci< it, 72,44, iI ELI:, These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect. Hazel Dell Christian Church Education Wing Addition SITE DETAILS C 502 Data Table algei o}DQ See Structure ID fl NOTCH TOP OF PILING r 4 or less or less Guardrail Elevation Scale: 1/2" 1' -0" Within 5' of edge of pavement Within 5' of edge of pavement 5' -0" MAX. 5/8" HD GALV. BOLTS WITH H.D. WASHER AT HEAD AND NUT; INSTALL (2) BOLTS AT POST LOCATIONS BETWEEN PIERS E.O.P., curb, gutter, or similar structure Min. 6" topsoil to ensure grass growth if not under pavement Minimum trench width 1.25x(o.d.) 12" 'B' borrow or equiv.. granular material compacted to 95% standard proctor max. density Pipe, see site plan for type and size Rigid Pipe Bedding Section Not to Scale INSERT AT 1" =1' E.O.P., curb, gutter or similar structure Min. 6" topsoil to ensure grass growth if not under pavement 'B' borrow or equiv. granular material compacted to 95% standard proctor max. density Minimum trench width 1.25x(o.d.) 12" 8 crushed stone or approved equivalent. Class 1 bedding material hand tamped or walked into place. Pipe, see site plan for type and size Flexible Pipe Bedding Section Not to Scale INSERT AT 1" 1 —O" 2 "x2" at 5" O.C. Notes: Notes: 5/8" HD GALV. BOLTS WITH H.D. WASHER AT HEAD AND NUT; INSTALL (2) BOLTS AT POST LOCATIONS BETWEEN PIERS AIIIMIAMMEISSESEEMENETii Bedding and Backfill for water mains shall be sand in lieu of #8 crushed stone. All bedding and initial backfill shall be installed in 6" to 12" balanced lifts. A minimum of 9" of clearance shall be provided on each side of the installed pipe. All bedding and initial backfill shall be installed in 6" to 12" balanced lifts. A minimum of 9" of clearance shall be provided on each side of the installed pipe. Bedding and Backfill for water mains shall be sand in lieu of #8 crushed stone. Typ. Guardrail Section 1 Scale: 1/2" 1' -0" /X Greater than 5' from edge of pavement reater than 5' RAIL 4 "x6" POST 5'- 0 "o.c., EXTEND POST BOTTOM OF 2 "X12" AT PIER LOCATIONS 2 "x6" CAP (ROUND EDGES) 2 "x2" RAIL C� 5 "o.c. 2 "x8" RAIL ti E.O.P., curb, gutter, or similar structure Min. 6" topsoil to ensure grass growth \/"Y Greater than 5' from edge of pavement Minimum trench width 1.25x(o.d.) 12" Regular backfill Pipe, see site plan for type and size 'B' borrow or equiv. granular material compacted to 90% standard proctor max. density E.O.P., curb, gutter, or similar structure Min. 6" topsoil to ensure grass growth \x Regular backfill Minimum trench width 1.25x(o.d.) 12" #8 crushed stone or approved equivalent. Class 1 bedding material hand tamped or walked into place. Pipe, see site plan for type and size SANITARY STRUCTURE TABLE STORM STRUCTURE DATA TABLE J.R. Smith Heavy Duty Cast Iron Cleanout housing and cover, 4250 Series with gasket or approved equal. Exterior Cleanout Detail Not to Scale 4AJ, W J,A Top View Not to Scale 1/8 bend if cleanout occurs at end of line 18" sq. concrete pad trowel smooth and edge (in lawn or landscaped areas) End View Metal HDPE End Section Detail 3 Asphaltic mastic or butyl rubber seal between joints Full height manhole steps as specified 0 —ring gasket asphaltic mastic or butyl rubber seal at joints Base 6" or 8" per section Not to Scale INSERT AT 1" =1' 1# 6 1, See Structure y 6" a Standard Precast Manhole 0 Note: 6" 4000 psi concrete precast or poured in place E Box Inlet Detail Not to Scale Outlet pipe Curb or flat casting, see Profiles Casting frame and cover per Profiles 0 1 11 2' DIA. 111111111111111111111111111111111114k 1 611001 o o p' 0 o 0 Diameter Varies 0 J o 0 o 0 o O 0 p 0 0 00 Precast concrete adjuster rings if needed (4 max.) 5" min. Class "A" concrete a� a Eccentric cone or reducer cap as req'd by site conditions. Cone top to match adjusting ring profile NOTE: Concrete Manhole conforms to ASTM C478. See Construction Specifications for Alternate Materials. Precast concrete section Preformed hole to max. of pipe o.d. 6" with nonshrink cement grout Bench walls at min. per foot slope Manhole base set on 6" of or #2 stone NOTE: Manhole Detail is typical for sanitary and storm manholes except: 1. For sanitary manhole adjusting rings use butyl rubber base exterior backplaster material, j" 1/16" min. thickness, from 2" below top of cone to casting. 2. Manhole joints shall be o —ring gasket plus extrudable gasket (Kent Seal or equal), per ASTM C -443. 3. Connection of pipes to sanitary manholes shall be made using a flexible boot, Kor —n —seal flexible connector, cast —in —place Dura —seal gasket, A —lock gasket, or approved equal. SCHMIDT ASSOCIATES Wil -Fra -Mar Building 320 East Vermont Street Indianapolis, IN 46204 -2126 317 263 -6226 Fax: 317 263 -6224 Project No Project Date Produced Revision Date 2002 -036 March 15, 2004 CEC c ,rci< it, 72,44, iI ELI:, These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect. Hazel Dell Christian Church Education Wing Addition SITE DETAILS C 502