HomeMy WebLinkAboutAddition G-002 Site Plan pg. 4Hazel Dell Christian Church Existing Building Building Area: 33, 400 SF Construction Type: Type II -N Construction Area Separation Walls: Existing area separation wall indicated on the drawing. Boiler Room Separation: No Bolier Room serves the building. Electrical Room Separation: None required. Automatic Sprinklers: Provided throughout to permit nonrated corridor construction. Corridors: Corridors are permitted to be nonrated throughout, based upon automatic sprinkler protection [1004.3.4.3, exc. 5] log EXIST TWO —HOUR AREA SEPARATION WALL C OVERALL FLOOR PLAN 1/16" 1,_0" Building Code Summary-Hazel Dell Christian Church Education Wing Addition Applicable Code: 2003 Indiana Building Code Occupancy Classifications: Church Use- Group A -3 Occupancy [303.1] Construction Type: Type II -N Construction [603] Allowable Area: Unlimited area permitted for a Group A -3 Occupancy building that is one story, type II -N construction, without a legitimate stage, and automatic sprinkler protection with 60 feet of separation [507.9]. Area Separation Walls: Not required, based upon unlimited area provisions[507.9] Building Elements Fire resistive Requirements: Structural frame, roof, and interior partitions are nonrated [Table 6 -A] Exterior Walls: Exterior nonbearing walls are nonrated, since at least 40 feet of separation. Boiler Room Separation: No Bolier Room serves the building. Electrical Room Separation: None required. Corridors: Corridors are permitted to be nonrated throughout, based upon automatic sprinkler protection [1004.3.4.3, exc. 5] Exit Travel Distance: 110 feet maximum permitted to a corridor or an exit 225 feet maximum permitted to an exit an additional 100 feet permitted if the last portion of travel is within a corridor[1007.3.3] Occu ant Load Factors and Occu ant Load Re uirin 2 Exits: Assembly: Concentrated Use (Youth Room): 7 sf per person, 50 or more occupants. Assembly: Less Concentrated Use (Classrooms Platform): 15 sf per person, 50 or more occupants. Storage: 300 sf per person 30 or more occupants Youth Room: 3 exits required based upon calculated occupant load of 446. [1004.2.3.4] Panic Hardware: Exit doors serving an occupant load of 50 or more, and which are locking or latching, are required to have panic hardware [1007.3.10]. Automatic Sprinklers: Provided throughout to permit unlimited area, and to permit nonrated corridor construction. [904.2.4, 505.2, 1004.3.4.3, exc. 5] Fire Alarm System: Required throughout [305.9, 303.9] STAGE PREP PLATFORM ECHANICAL ELECTRICAL A105 C EQUIP. STORAGE PANTRY STORAGE CORRIDOR CORRID KITCHEN WORSHIP HALLWAY GATHERING SPACE 1 CORRIDOR STIBULE MULTI— PURPOSE CONFERENCE ANTS CRAWLERS OFFICE AREA 8103 FIRST GRADE 2ND GRADE 3RD GRADE CORRID CORRIDOR CHECK —IN fr) ;I FOURS CORRIDOR TODDLERS WALKERS EXISTING BUILDING NEW CONSTRUCTION s Buildina Size Existing Building: 33,613 SF New Addition: 13, 514 SCHMIDT WW1/ Mr l ir //A :1'1,4 1 ASSOCIATES 2000 -036 February 26, 2003 Project No Project Date Produced Revision Date QC REVIEW CONSTRUCTION DOCUMENTS NOT FOR CONSTRUCTION These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect. Hazel Dell Christian Church Education Wing Addition OVERALL FLOOR PLAN G -002